Q Global Solutions QBUN-D-RF0612 BUN-D RF control module User Manual

Q Global Solutions (Xiamen) Electronics Corp. BUN-D RF control module Users Manual

Users Manual

Download: Q Global Solutions QBUN-D-RF0612 BUN-D RF control module User Manual
Mirror Download [FCC.gov]Q Global Solutions QBUN-D-RF0612 BUN-D RF control module User Manual
Document ID793815
Application IDrWuukIDsKnZrO6ShRuNO+A==
Document DescriptionUsers Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize6.43kB (80433 bits)
Date Submitted2007-05-18 00:00:00
Date Available2007-05-18 00:00:00
Creation Date2007-01-23 16:42:52
Producing SoftwareAcrobat Distiller 5.0 (Windows)
Document Lastmod2007-01-23 16:42:52
Document TitleUsers Manual

BUN-D-RF User Manual
1、Principle of
system working
1.1 System connection
Momentory switch
Dome Buzzer power line
B1 B2 B3 B4
A1
A2
A3
RED
GREEN
RED
BLACK
RED
BLACK
BLACK
Control module power line
A4 A3 A2 A1
Latching relay Dome Buzzer (RF)
Digital Sensor
Digital Sensor extension cable
BUN-D RF control module
2、System function
2.1 Self-diagnosis
two-Sensor system (SENSOR1、SENSOR2)
power on,the system starts its self-diagnosis.
a. No SENSOR:three beeps.
b. one SENSOR:two beeps.
c. two SENSOR:connect to CL、CR or L、R ,one beep;
Three beeps for other conditions.
2.2 Front system/Reverse system shift
Switch 1 OFF:Reverse system
Switch 1 ON: Front system
2.3 Corner SENSOR maximum detection distection shift
Switch 2 OFF:Reverse system,the maximum detection
distance is 6ft;
Front system,the maximum detection distance is 3ft.
Switch 2 ON: Reverse sysytem,The maximum detection distance is
3ft.
Front system. the maximum detection distance is 2ft.
2.4 Detection distance
2.4.1
Obstacle position to its nearest sensor
buzzer warning
7ft-4ft(middle SENSOR)
6ft-4ft(corner SENSOR)
4ft-2ft
within 2ft
intemittent beeps
Rapid beeps
Solid beep
2.4.2
Obstacle position to its nearest sensor
buzzer warning
3ft-2ft
itermittent beeps
2ft-1ft
Rapid beeps
within 1ft
solid beep
2.5 Buzzer volume adjust
Press the adjust switch, Buzzer beeps shortly, the volume from high to low, press
again, the volume from low to high. The volume is stored everytmie the switch is
pressed. The last volume remains until power on again.
2.6 Fixity learning
To assure there is no false warning because of the fixity, the system should learn
the enviroment. Learning method:after inatalling the sensor and control module,
remove all obstacles in front or back of the vehicle. Power on, the system will warn
if there is fixity. Then, power off. Redo "on-off" for four times.( "off" time < 3
seconds), if "off" is > 5 seconds, the learning process stops. No time limit for "on"
time.) Wherein, the system enter learnig status, BUZZER beeps for 2 seconds, the
system stores the fixity into its memory.(the fixity distance< 1m). There will be no
false warning because of the fixity.
2.7 Switch control function
Power on, LED of Momentary switch lights up , the system starts to work for 5
minutes, then shut off automatically.LED turns off.
In operation time, press Momentary switch,the system shuts off at once. LED of
Momentary switch turns off;
When the system is in off satus,press Momentary switch,the system restart and
work for five minutes.
When LED flashes, it shows that sensor has some problems.
3、System components
3.1 Control module
Basic Specification
Item
Specification
1. Rating voltage
DC12V
2. Operating voltage
DC9.6V--16V
3. Consume current
MAX40mA/12V
4. Operating temperature
-30°C----+80°C
5. store temperature
-40°C---+85°C
6. output frequency
40KHz ? à 2KHz
7. detection range
8. Emiting frequency
0~2ft~4ft~7ft
433.92MHZ±75KHZ
3.2 Sensor and Sensor cable
Basic Specification
Item
Specification
1、Operating temperature-30°C----+80°C
2、Store temperature
-40°C---+85°C
3、input frequency
40KHz ± 2KHz
4、Maximum detection distance
7ft
5、Detecting angle
Plane 100°±20°
Vertical 50°±10°
6、Detecting method
Ultrasonic 40KHz
3.3 Lathing relay rf dome buzzer and momentary switch
Basic Specification
Item
1、Rating voltage
2、operating voltage
range
3、Consume current
4、temperature
5、store temperature
6、volume
7、Volume frequency
Parameter
12V
DC 9.6V--16V
MAX40mA/12V
-30°C----+80°C
-40°C---+85°C
high:85±5 dB/10cm/12v
low:75±5 dB/10cm/12v
1600Hz
4 、Changes or modifications not expressly approved by the party
responsible for compliance could void the user's authority to operate the
equipment.

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.3
Linearized                      : No
Create Date                     : 2007:01:23 16:42:52+08:00
Modify Date                     : 2007:01:23 16:42:52+08:00
Page Count                      : 4
Creation Date                   : 2007:01:23 08:42:52Z
Mod Date                        : 2007:01:23 08:42:52Z
Producer                        : Acrobat Distiller 5.0 (Windows)
Metadata Date                   : 2007:01:23 08:42:52Z
EXIF Metadata provided by EXIF.tools
FCC ID Filing: UWRQBUN-D-RF0612

Navigation menu