Qolsys QS1200 is a wireless motion sensor to be used in the Qolsys IQ home security system. User Manual

Qolsys, Inc. is a wireless motion sensor to be used in the Qolsys IQ home security system.

User Manual

IQ MOTION- INSTALLATION MANUALQOLSYS CONFIDENTIAL AND PROPRIETARY  PAGE 1 OF 6© Last revised 2/27/15 All rights reservedThe Qolsys IQ Motion is a high-performance wireless motion sensor that uses advanced power circuit technology to extend battery life. The tamper-resistant casing along with an electronic sensor discourages physical tampering and the sensor is equipped with a pet immunity feature that prevents accidental triggers by household pets. The IQ Motion works seamlessly with the Qolsys IQ Panel.  •Advanced circuit technology resulting in ultra-low power consumption•Tamper detection/reporting•Rigid wall mounting for discreet placement•Pet immunity •Easy to install batteries•Supervisory health messaging•Sensor Motion detection•Transmits 2 signals per 5 minute periodPIR (Passive Infrared) Motion Sensors2 Mounting screws2 AAA Alkaline batteriesPRODUCT FEATURESPARTS INCLUDEDIQ MOTION•Wireless signal range: 600 ft (200 m), open air•Code outputs: paring, tamper, tamper restore, alarm detect motion, alarm restore, supervisory, low battery•Transmitter frequency: 319.5MHZ +-15KHz •Transmitter bandwidth: 24KHZ•Modulation type: ASK-OOK•RF output power!91.1dBuV +/- 5% at 3m •Sensor Range 30 ft (9.1 m) x 50 ft (15.2 m) •Maximum Horizontal Sensing Angle 80°TECHNICAL SPECIFICATIONS
IQ MOTION- INSTALLATION MANUALQOLSYS CONFIDENTIAL AND PROPRIETARY  PAGE 2 OF 6© Last revised 2/27/15 All rights reserved•IQMotionSensor is designed for indoor use and is compatible with homes where pets up to 40 lbs (18 kg) are present. To minimize the possibility of false alarms the following guidelines should be followed:•The sensor may be mounted in a corner or on a flat wall that is free of vibrations.•If possible, mount the sensor within 100 ft (30.5 m) of the panel. While the transmitter may have a range of 600 ft (200 m) or more out in the open, the environment at the installation site can have a significant effect on transmitter range. Verify actual transmitter range for each installation.•Position the sensor to protect an area where an intruder is most likely to walk across the detection pattern.•Mount the sensor permanently on a flat wall or in a corner. •Mount the sensor on an interior wall facing in.•Position the sensor so it faces a solid reference point, such as a wall.•Close all windows in an area with an armed motion sensor.DO NOT: •Aim the sensor at windows, fireplaces, air conditioners, area heaters, or forced air heating vents.•Place the sensor in direct sunlight as sudden changes in temperature may trigger a false alarm.•Mount the sensor near duct work or other large metallic surfaces that may affect the RF signals.•Set the sensor on a shelf.GUIDELINESFlush-mount or corner-mount the sensor depending on the selected location and desired coverage areaMOUNTING OPTIONSBATTERY ACTIVATIONTo activate the batteries in the sensor, remove the cover and pull out the plastic tab between the batteries and the contacts.  CORNER STRAIGHT MOUNTCORNER ANGLE DOWN MOUNTFLUSH WALL MOUNTFor pet immunity from a cornerFor pet immunityNo pet immunity
IQ MOTION- INSTALLATION MANUALQOLSYS CONFIDENTIAL AND PROPRIETARY  PAGE 3 OF 6© Last revised 2/27/15 All rights reservedMOUNTING INSTRUCTIONSRemove back cover by pressing bottom button and sliding back cover off in an upward motion.  If a flush mount is required screw in the back cover on the wall using the screw templates as shown.  If corner mount is required use the screw templates as shown.MOUNTING FOR PET SENSITIVITYMount the sensor 6.5 to 7 ft (0.9 and 1.5 m) high. For best results, install the sensor higher than the highest point the pet might reach in the detection area.  Use the following formula to calculate the optimal mount height:  mount height = pet’s stature + (distance/20). That means when the farthest sense area to sensor is 33 ft (10 m), and the pet’s stature is 2.6 ft (0.8 m), mount 4.25 ft (1.3 m) from the floor. (Do not exceed the highest 5 ft [1.5 m]). If the detection area contains furniture or other objects on which the pet can climb or jump, either (a) remove these objects, (b) mount the sensor a safe distance above these objects, or (c) mask these areas.
IQ MOTION- INSTALLATION MANUALQOLSYS CONFIDENTIAL AND PROPRIETARY  PAGE 4 OF 6© Last revised 2/27/15 All rights reservedPROGRAMMING THE IQ DOOR/WINDOW The$following$steps$describe$general$guidelines$for$programming$(learning)$the$sensor$into$the$IQ$Panel.$Refer$to$the$IQ$Panel's$installation$instructions$for$complete$programming$details.$From the home screen of the IQ panel, touch the “Settings” iconEnter$the$installer$passcode.$$Default$installer$passcode$is$11111 2Touch the “Installation” app Touch the “Security Sensors” app3 4Touch the “AutoLearn Sensor” appTamper$the$sensor$by$pressing$the$tab$and$liBing$off$the$cover.$$5 4A chime will sound Touch$“Ok”6 78Check the auto-populated fields to ensure accuracy.  Change the settings as you see fit.  Be sure to select the proper “Sensor Group”9Create custom names by selecting “Sensor name” and choosing “Custom description.” A box will appear to the right.  Selecting that box will open a keyboard, allowing you to type the name of your choice into the field.  10 Touch “Add” to complete the process
IQ MOTION- INSTALLATION MANUALQOLSYS CONFIDENTIAL AND PROPRIETARY  PAGE 5 OF 5© Last revised 2/27/15 All rights reservedBATTERY REPLACEMENTTo replace batteries:•Push button on side of sensor and lift off cover.•Remove old batteries and replace with new ones.    •Close cover by snapping the cover back onto the sensor.AAA Alkaline (2 per sensor) Battery life expectancy: 3 years. (Lifetime may vary depending on number of activations, environmental conditions, etc.)BATTERY TYPEOperating Temperature: -10C~50C (TBD)Relative Humidity: 5-85% Storage Temperature: -40-80C ENVIRONMENTAL CHARACTERISTICSSensor: 3.4H x 2.4W x 1.5D in. (7.7x6.0x4.3 cm)Number of sensing elements: 2Spectral Response:  5um – 14umSensor Responsivity (500K, 1Hz):  3.6mVp-pPet Immune to 50 lbs.  Pets must not be allowed to jump up on tables or furniture within the detection area.SPECIFICATIONSSUPPORTGOT QUESTIONS?CONTACT TECH SUPPORTTechSupport@Qolsys.com?
IQ DOOR/WINDOW- INSTALLATION MANUALIMPORTANT INFORMATION15.21§ 15.21 Information to user.The users manual or instruction manual for an intentional or unintentional radiator shall caution the user that changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.CAUTION:! Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.!15.105(b)§ 15.105 Information to the user.!(b) NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:—Reorient or relocate the receiving antenna.—Increase the separation between the equipment and receiver.—Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.—Consult the dealer or an experienced radio/TV technician for help.RSS-GEN Section 8.48.4 User manuals for licence-exempt radio apparatus shall contain the following text, or an equivalent notice that shall be displayed in a conspicuous location, either in the user manual or on the device, or both:This device complies with Industry Canada’s licence-exempt RSSs. Operation is subject to the following two conditions:(1) This device may not cause interference; and(2) This device must accept any interference, including interference that may cause undesired operation of the device.QOLSYS CONFIDENTIAL AND PROPRIETARY  PAGE 6 OF6© Last revised 2/27/15 All rights reservedDocument#: IQM-IM-02-15Revision#: 2/27/15Issue Date: FEB 2015Qolsys Part #: QS-1200-p01Firmware : 0B_20130627Conforms to ANSI/UL Std. 639Certified to ULC Sub S306 Qolsys Inc. proprietary.  Reproduction without permission is not permitted.