Quanta Microsystems ZM101 IEEE 802.15.4 transceivers Module User Manual OP ZM10X 1 R01
Quanta Microsystems, Inc. IEEE 802.15.4 transceivers Module OP ZM10X 1 R01
manual
Quanta Microsystems Inc. ZM101 module operation manual-RF mode Quanta Microsystems, Inc. Subject: Doc No. ZM10 operation manual-RF mode Revised Date: OP_ZM10X-1 2008/03/28 Rev: Page: Reason for Release: Revision Effective Date Author 0.1 03/28/2008 Samuel Wang Description of Changes Modified from OP_ZM100-1 QMI PROPERTY & CONFIDENTIAL! 0.2 2 of 10 Quanta Microsystems, Inc. Subject: Doc No. 1. ZM101 operation manual-RF mode Revised Date: OP_ZM10X-1 2008/03/28 Rev: Page: 0.2 3 of 10 Adaptor board connection and setup Power IN (+2.7~+3.3Vdc) USB plug in: ― J_USB should be selected as USB PWR IN mode ― USB +5V Æ LDOÆPower in RCA Jack plug in: ― J_DC should be 2-3 pin short. ― Use a +4~7V(inner) DC adaptor plug in CON_RCAÆ LDOÆPower in Pin header plug in: ― Use other power source(such as power supply) ― Supply +2.7~+3.3V and plug in by J_3V pin headerÆPower in Fig1.1 Adaptor board and DUT test setup QMI PROPERTY & CONFIDENTIAL! Quanta Microsystems, Inc. Subject: Doc No. ZM10 operation manual-RF mode Revised Date: OP_ZM10X-1 2008/03/28 Rev: Page: 0.2 4 of 10 Adaptor board placement and jumper selection J_CURRENT: For DC current measurement use; Default is short by Jumper. J_DC: DC input selection ― 1-2 Short by Jumper : Use USB +5VÆLDOÆ3.3V ― 2-3 Short by Jumper : Use RCA Jack ― Open : Use J_3V pin header CN USB: Insert USB A-type cable connect to USB host to provide +5Vdc. CN_RCA : Provide +4~7Vdc by RCA Jack. J_3V : Provide +2.7~3.3V by pin header, positive port are marked in square. CN9 : D-SUB9 for UART console. CON4 : insert 4-wire cable connect to DUT for FW download. CON6 : insert 6-wire cable connect to DUT for RF testing. QMI PROPERTY & CONFIDENTIAL! Quanta Microsystems, Inc. Subject: Doc No. ZM101 operation manual-RF mode Revised Date: OP_ZM10X-1 2008/03/28 Rev: Page: 0.2 5 of 10 FW download Connect 4pin connector to adaptor and use USB multi-link or programmer download, 2X3 pin header pin1 are marked in square. Open OS hyper terminal as a com port used UART connection Use a D-SUB9 cable connects to PC com port Open OS hyper terminal as a com port used Set properties as following Fig 1.1 Hyper terminal COM port settings QMI PROPERTY & CONFIDENTIAL! Quanta Microsystems, Inc. Subject: Doc No. ZM101 operation manual-RF mode Revised Date: OP_ZM10X-1 2008/03/28 Fig 1.2 Hyper terminal Properties settings QMI PROPERTY & CONFIDENTIAL! Rev: Page: 0.2 6 of 10 Quanta Microsystems, Inc. Subject: Doc No. ZM101 operation manual-RF mode Revised Date: OP_ZM10X-1 2008/03/28 Rev: Page: 0.2 7 of 10 Fig 1.3 ASCII setup After finished above item, connect DUT and adaptor board by 6pin wire connection. Then it will be operating as RF test mode QMI PROPERTY & CONFIDENTIAL! Quanta Microsystems, Inc. Subject: Doc No. 2. ZM101 operation manual-RF mode Revised Date: OP_ZM10X-1 2008/03/28 RF test mode application Channel selection Set channel ― Select character “1,2,3….,f,g to set channel 1~16 QMI PROPERTY & CONFIDENTIAL! Rev: Page: 0.2 8 of 10 Quanta Microsystems, Inc. Subject: Doc No. ZM101 operation manual-RF mode Revised Date: OP_ZM10X-1 2008/03/28 Set output power ― Default power: -0.66dBm (select character “n”) QMI PROPERTY & CONFIDENTIAL! Rev: Page: 0.2 9 of 10 Quanta Microsystems, Inc. Subject: Doc No. ZM101 operation manual-RF mode Revised Date: OP_ZM10X-1 2008/03/28 Rev: Page: 0.2 10 of 10 Set operation mode ― Select character “v,w,x…r,s” for operation mode After you finished testing, you can select character “t” to go back to main manual. If you can not go back to main manual (ex. DUT on sleep mode); it shall be power off then power on DUT to go back to main manual. QMI PROPERTY & CONFIDENTIAL! 10 Federal Communication Commission Interference Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. FCC Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. FCC Radiation Exposure Statement: This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. This device is intended only for OEM integrators under the following conditions: 1. The antenna must be installed such that 20 cm is maintained between the antenna and users, and 2. The transmitter module may not be co-located with any other transmitter or antenna, IMPORTANT NOTE: In the event that these conditions can not be met (for example certain laptop configurations or co-location with another transmitter), then the FCC authorization is no longer considered valid and the FCC ID can not be used on the final product. In these circumstances, the OEM integrator will be responsible for re-evaluating the end product (including the transmitter) and obtaining a separate FCC authorization. 11 End Product Labeling This transmitter module is authorized only for use in device where the antenna may be installed such that 20 cm may be maintained between the antenna and users. The final end product must be labeled in a visible area with the following: “Contains FCC ID:T5U-ZM101”. Manual Information To the End User The OEM integrator has to be aware not to provide information to the end user regarding how to install or remove this RF module in the user’s manual of the end product which integrates this module. The end user manual shall include all required regulatory information/warning as show in this manual. 12
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : No XMP Toolkit : 3.1-701 Producer : Acrobat Distiller 7.0 (Windows) Create Date : 2008:03:28 16:27:40+08:00 Creator Tool : PScript5.dll Version 5.2 Modify Date : 2008:04:07 15:10:39+08:00 Metadata Date : 2008:04:07 15:10:39+08:00 Format : application/pdf Title : Microsoft Word - OP_ZM10X-1_R01.doc Creator : 95031302 Document ID : uuid:272f3a0d-b1ea-4bf2-9285-313ec4651887 Instance ID : uuid:bd8ce876-7239-438b-be73-caa6b6e1de61 Page Count : 12 Author : 95031302EXIF Metadata provided by EXIF.tools