Quantum Data 802Bt Users Manual Ug
802BT to the manual f5df4673-df5d-48e7-8517-1bfea67e2818
2015-02-05
: Quantum-Data Quantum-Data-802Bt-Users-Manual-492762 quantum-data-802bt-users-manual-492762 quantum-data pdf
Open the PDF directly: View PDF .
Page Count: 744
Download | |
Open PDF In Browser | View PDF |
802BT/802R Video Test Generator User Guide 802BT/802R Video Test Generator, User Guide, Revision A.5 (12/22/04) Copyright 2004 Quantum Data. All rights reserved. The information in this document is provided for use by our customers and may not be incorporated into other products or publications without the expressed written consent of Quantum Data. Quantum Data reserves the right to make changes to its products to improve performance, reliability, producibility, and (or) marketability. Information furnished by Quantum Data is believed to be accurate and reliable. However, no responsibility is assumed by Quantum Data for its use. Updates to this manual are available at http://www.quantumdata.com/support/downloads/. Contents Chapter 1 Getting Started Product overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Standard features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Optional features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Physical controls. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Power switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Format knob . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Image knob . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Image Step key . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 R, G, B Video Gate keys . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 ACS, DCS, and DSS Sync Gate keys . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Outputs Key . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 LCD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Video interfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 VGA interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 DVI-I interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 LVDS interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Special Sync (S/S) interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 S-Video interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Composite video BNC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Component video BNC interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Computer interfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 RS-232 interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 GPIB interface (optional) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 802BT/802R Video Test Generator User Guide i USB interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 PCMCIA interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Command interfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Setting up a terminal connection with the generator. . . . . . . . . . . . . . . . . . . . . . . . . 14 Changing the baud rate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Sending commands interactively . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Sending commands from text files . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 Special operating modes. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 Summary of special modes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 Special key operations summary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 About Video Generator Manager . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 VGM features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 Installing VGM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 Chapter 2 Testing Video Displays General video display testing procedure. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 Making physical connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 Setting the video output mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 Selecting video formats . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 Selecting formats automatically . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 Selecting formats manually . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 Understanding the format library . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 Organization of format library . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 Viewing format parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 Selecting images . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 Testing analog computer (IT) CRTs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 Testing digital computer (IT) FPDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34 Testing analog composite video SDTV (CE) CRTs . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 Testing analog component video SDTV (CE) CRTs . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 Testing digital component video HDTV (CE) flat panel displays. . . . . . . . . . . . . . . . . . . 40 Chapter 3 Administrative Tasks Displaying system information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44 Restoring factory settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45 Setting and restoring system parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45 ii Contents Calibrating the generator. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47 Calibrating frequency . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48 Cloning generators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49 Installing firmware . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 Memory management . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51 Chapter 4 Working with Formats Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54 Format library . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55 Compatibility . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55 Format naming conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56 Composite television format names . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56 Component television format names . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57 Computer display format names. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58 Aperture designators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59 Using legacy format names . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60 Viewing the format library . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61 Viewing format details. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61 Creating custom formats . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63 Determining the signal specifications of the display . . . . . . . . . . . . . . . . . . . . . . . . . 63 Creating custom formats using the command line interface. . . . . . . . . . . . . . . . . . . 63 Creating a new format . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63 Creating a format based on an existing format . . . . . . . . . . . . . . . . . . . . . . . . . 64 Modifying existing formats . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65 Editing Format knob lists. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67 Editing format knob list using internal editor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67 Editing format knob list using command line interface . . . . . . . . . . . . . . . . . . . . . . . 69 Configuring DCS priority scheme . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70 Creating format aliases . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72 Chapter 5 Working with Images Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74 Viewing the image list . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74 Creating custom images . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75 Command file example . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 76 802BT/802R Video Test Generator User Guide iii Downloading bitmap images from a PCMCIA card . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78 Looping through images . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80 Editing Image knob list . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81 Editing image knob list using internal editor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81 Editing Image knob list using command line interface . . . . . . . . . . . . . . . . . . . . . . . 82 Creating image aliases . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84 Chapter 6 Working with Test Sequences Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86 Creating a test sequence . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87 Creating a test sequence using command line. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87 Creating and editing test sequences using the internal editor . . . . . . . . . . . . . . . . . 88 Viewing the test sequence list. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92 Viewing the test sequence list using the command line . . . . . . . . . . . . . . . . . . . . . . 92 Deleting a test sequence using the command line . . . . . . . . . . . . . . . . . . . . . . . . . . 92 Viewing test sequence using internal sequence editor. . . . . . . . . . . . . . . . . . . . . . . 93 Running a sequence . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 94 Running a test sequence using the command line . . . . . . . . . . . . . . . . . . . . . . . . . . 94 Running a test sequence using internal sequence editor . . . . . . . . . . . . . . . . . . . . . 95 Cancelling the start-up sequence mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 96 Chapter 7 Using GPIB Interface Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 98 Setting the GPIB port address . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99 Queries and commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100 Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100 Queries . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 101 Sending commands and queries . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 102 Sending multiple commands and queries per line . . . . . . . . . . . . . . . . . . . . . . 102 Completion handshake . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 103 Input buffer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 103 Status queries and control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 104 Status byte . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 104 Requesting service. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 104 Bus commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 106 iv Contents Remote/local operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 106 Chapter 8 Analyzing Digital Sources and Cables Getting started. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 110 HDMI analyzer connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 110 Monitoring HDMI analyzer signal input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 110 DVI analyzer connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 111 Starting the Analyzer Setup Utility . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 112 Enabling and disabling analyzer images . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 112 Measuring timing of video signal. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 114 Setting up analyzer to measure timing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 114 Measuring basic timing parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 115 Measuring detailed timing parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 116 Testing cables and distribution systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 118 Testing accuracy of analyzer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 120 Measuring pixel errors. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 123 Setting delta error patch parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 123 Measuring pixel errors in patch. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 125 Testing InfoFrames (HDMI only) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 127 Testing HDMI transmit device InfoFrame capability . . . . . . . . . . . . . . . . . . . . . . . . 127 Testing audio (HDMI only) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 129 Testing HDMI transmit device audio capability. . . . . . . . . . . . . . . . . . . . . . . . . . . . 129 Controlling analyzer using command-line interface . . . . . . . . . . . . . . . . . . . . . . . . . . . 130 Signal timing analysis commands. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 130 Viewing signal timing parameters (on an HDMI/DVI monitor) . . . . . . . . . . . . . 130 Viewing specific timing parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 130 Pseudo-random noise generation commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . 132 Generating pseudo-random noise . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 132 Pseudo-random noise analysis commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 132 Analyzing pseudo-random noise in a cable or distribution system . . . . . . . . . 133 Analyzing pseudo-random noise from an external source . . . . . . . . . . . . . . . . 134 Testing the analyzer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 134 Analyzing pixel data (delta error patch) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 135 Generating pseudo-random noise from your device . . . . . . . . . . . . . . . . . . . . . . . . . . . 137 802BT/802R Video Test Generator User Guide v Implementing pseudo-random noise from your device. . . . . . . . . . . . . . . . . . . . . . 137 lfsr.h . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 137 lfsl.cpp . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 138 Sending pseudo-random noise to external device . . . . . . . . . . . . . . . . . . . . . . . . . 140 Analyzing noise from an external device . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 141 Setting pseudo-random noise parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 142 Chapter 9 Testing HDMI Sink Devices Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 146 Getting started. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 147 HDMI connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 147 Setting up the generator for HDMI operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 147 Testing HDMI video. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 149 Testing HDMI video formats . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 150 Testing HDMI video pixel repetition . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 152 Testing HDMI audio . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 155 Testing 2-channel HDMI audio output from internal SPDIF source . . . . . . . . . . . . 155 Testing 8-channel HDMI audio output from internal source . . . . . . . . . . . . . . . . . . 157 Testing HDMI audio using an external audio source . . . . . . . . . . . . . . . . . . . . . . . 158 Testing HDMI InfoFrames . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 161 Viewing InfoFrame contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 161 Testing with Active Format Description (AFD) . . . . . . . . . . . . . . . . . . . . . . . . . . . . 162 Chapter 10 Testing EDID Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 166 EDID testing for source devices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 167 Testing response of source to EDID. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 167 EDID testing for sink devices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 171 Viewing EDID from a display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 171 Writing EDID data to a display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 172 Testing EDID in HDMI sink device for HDMI compliance . . . . . . . . . . . . . . . . . . . . 173 Overview of HDMI compliance testing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 173 Testing HDMI sink devices for EDID compliance. . . . . . . . . . . . . . . . . . . . . . . 174 Visual verification of formats . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 182 vi Contents Chapter 11 Testing HDCP Testing DVI or HDMI receiver with HDCP. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 186 Testing HDCP between HDMI transmitter and DVI receiver. . . . . . . . . . . . . . . . . . . . . 188 Testing HDCP with static images . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 189 Using command-line interface to control HDCP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 190 HDCP? command. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 190 Troubleshooting HDCP errors. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 191 Common problems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 191 Running HDCP test in step mode. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 191 Running an HDCP self-test. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 191 Understanding the HDCP test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 192 Chapter 12 Using Special Sync Output Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 196 Operating special sync for probe pulse. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 197 Front panel controls and indicators. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 197 Probe coordinate numbering . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 197 Configuring the probe feature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 198 Setting sensitivity of knobs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 198 Controlling probe using generator controls. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 198 Controlling probe using command line interface. . . . . . . . . . . . . . . . . . . . . . . . . . . 199 Configuring special sync for FS, LS or CS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 201 Appendix A Command Reference Commands by name . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 204 Appendix B Image Reference Standard image descriptions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 604 Appendix C Error Messages System errors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 708 Power-on self test messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 708 Power fail message . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 709 Format errors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 710 Invalid data error messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 710 Corrupt data error messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 710 802BT/802R Video Test Generator User Guide vii Error code descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 711 2000-2999 Format errors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 711 3000-3999 Image errors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 722 4000-4999 Test sequence errors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 724 5000-5999 Directory errors. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 725 6000-6999 Bitmap errors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 726 7000-7999 LUT errors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 726 8000-8999 Font errors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 727 9000-9999 System errors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 727 10000-10999 System errors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 732 viii Contents 1 Getting Started Topics in this chapter: • Product overview • Operating the generator • Video interfaces • Command interfaces • Special operating modes • About Video Generator Manager 802BT/802R Video Test Generator User Guide 1 Product overview The generator enables you to test a broad range of video displays including composite or component television video signals as well as computer video display terminals. The generator enables you to quickly set the format appropriate for each display simply by twisting a knob. The generator’s functions can be customized to support video display testing in a variety of environments such as development, repair center, or production line. Standard features There are over 250 built-in video formats with the generator including VESA, ATSC, EIA-770, SMPTE, NTSC, and PAL. The generator contains a library of over 250 test images which enables comprehensive testing of color, size, linearity, convergence, focus, persistence, and more. You can create custom formats and images, and create test sequences to automatically progress through a list of formats and images for production line environments. You can also configure the generator to continuously loop through the test images. The generator provides a hot sync feature through the VGA, DVI, or HDMI interface. This feature simplifies format selection by filtering formats in accordance with the Extended Display Identification Data (EDID) it receives and processes from the display. A probe pulse feature is available on the Special Sync BNC connector. This enables you to trigger an oscilloscope or to synchronize an inspection camera. You can position the leading edge of the probe pulse anywhere within the video frame. This feature facilitates troubleshooting by enabling you to focus on very specific video signal problems occurring anywhere in the video signal. The probe BNC connector can also be configured to output frame sync, line sync, composite sync, or a special probe pulse. You can control the generator using the front panel knobs and keys, a command line interface, or a Windows-based graphical application called Video Generator Manager (VGM). The generator supports custom data backup, automatic or on-demand calibration, and downloadable firmware upgrades. Optional features Your generator may include one or more of the following options: • 2 Digital Visual Interface (Single Link and Dual Link). The generator can be equipped with a single link or dual link Digital Visual Interface (DVI) transmitter. The DVI transmitter enables testing of DVI compliant video displays. The DVI option includes EDID parsing and a hot-plug, EDID-driven format list. Chapter 1 Getting Started • High Bandwidth Digital Content Protection (HDCP). Generates HDCP encrypted content for testing DDCP-compliant displays. • DVI or HDMI Analyzer. Optional receiver, which measures pixel errors at different frequencies, measures timing of external sources, and displays EDID from external sources. Can also be used to test cables or distribution systems. • High Definition Multimedia Interface (HDMI). The HDMI feature helps manufacturers increase the likelihood that their products will not only meet compliance standards, but also flawlessly interoperate with other HDMI devices. • General Purpose Interface Bus (IEEE-488). Use to operate the generator in an automated environment. • Component video BNC connectors. The generator can be equipped with R, G, B, VS, and HS/CS BNC connectors. 802BT/802R Video Test Generator User Guide 3 Operating the generator This section describes basic operating procedures. There are four operational interfaces for controlling the generator. • Physical controls. Most of the generator’s features and functions are supported using the front panel using the knobs and keys. Functions which are not supported using the front panel include upgrading the firmware, creating and editing formats, creating and editing images and reconfiguring the format and image knob lists. • Command line. An ASCII command line interface, available through the RS-232 port, allows you to send commands either interactively or as command files. All functions are supported by the command line interface except upgrading firmware. • Video Generator Manager (VGM). VGM is a Windows-based application that supports most generator functions using a graphical user interface. When upgrading the generator firmware, VGM must be used. • GPIB Programmatic interface (optional). An IEEE-488 GPIB interface supports the use of the 802 as a programmable video signal source in an automated test evironment. All generator commands are supported through this interface. Physical controls The physical controls on the generator consists of the Format knob, Image knob, and eight keys, arranged into four function groups: Image, Video Gate, Sync Gate, and Outputs. All of the keys have built-in indicator lights. When illuminated, a key’s function is considered on, or enabled. Power switch This rocker switch turns the power on and off. The power supply is auto switching and can handle 110 or 220v. Format knob The Format knob is used to select a video signal format from a list of stored formats. A format is a set of parameters that specifies the video and sync signal requirements of a particular timing. Format parameters include timing, sync type, video type, display size, and others. By turning the knob, you can scroll through a list of formats stored in non-volatile memory. The list includes the factory default formats. The knob list can be edited to add custom formats. If a format containing erroneous information is selected, the generator turns off the outputs, and displays an error message. 4 Chapter 1 Getting Started Image knob The Image knob is used to select a test image from a list of stored images. The exact behavior of the knob depends upon the status of the Image key. Turning the knob when the light on the Image key is extinguished scrolls through the main list of test images. Not all images are supported by all signal formats. Some images in the main image list may be skipped while certain formats are selected. For example, the ColorBar image will be skipped whenever a monochrome format is selected.If the currently selected image cannot be drawn given a newly selected format, the Outline image is automatically drawn after the new format has finished loading. Some of the image names in the main list may refer to a sub-set of two or more different images. The images in the sub-sets are selected by first selecting the name of the desired sub-set from the main image list. If the sub-set consists of just two images, pressing the Image key will toggle between the two images. The key is illuminated when the second image is showing. Image Step key The Image Step key determines the behavior of the Image knob in normal operating mode where it is used to select alternate versions of a given test image. The Step key will illuminate only when you have selected an image with multiple versions. The following procedure describes how to select image versions. To select image versions: 1. Using the Image knob, select an image that has multiple versions. 2. Press the Step key. The key illuminates. 3. Turn the Image knob to step through the image versions. As you turn the knob, the image name on the LCD will not change. 4. Press the Step key again. The light on the key extinguishes, and the Image knob returns to normal operation. 802BT/802R Video Test Generator User Guide 5 R, G, B Video Gate keys The Video Gate keys activate (turn on) or deactivate (turn off) individual color elements when the generator is in normal operating mode. They also control the addition of primary color information to the NTSC / PAL video outputs on the generator. The following table shows the function of the Video Gate keys, and commands for controlling the key function. Key Function Command R Turns all of the red video outputs on and off. REDG G Turns all of the green video outputs on and off. When a 2-bit digital monochrome (MDA) signal is being generated, the G key turns the I (intensity) signal of the video pair on and off. GRNG B Turns all of the blue video outputs on and off. BLUG When a 1 or 2- bit digital monochrome signal is being generated, the B key turns the V (video) signal on and off. The master Outputs key overrides the settings of these keys when turned off. ACS, DCS, and DSS Sync Gate keys The Sync Gate keys are used to activate (turn on) or deactivate (turn off) sync signals when the generator is in normal operating mode. With some formats, more than one type of sync can be selected by pressing two keys together. Key Function Command ACS Outputs analog composite sync on one or more of the analog video outputs. SSST 3; ALLU DCS Outputs digital composite sync signal. SSST 2; ALLU DSS Outputs separate digital horizontal and vertical sync signals. SSST 1; ALLU The generator selects a default sync type whenever you select a new format. Not all sync types are available with all formats. For example, digital video formats will not allow analog composite sync to be selected. If a key will not illuminate when pressed, then the corresponding sync type is unavailable. Repeatedly pressing a sync gate key causes the selected sync to be toggled on and off. When toggled off, no sync will be sent to the display. The master Outputs key overrides the settings of these keys when turned off. 6 Chapter 1 Getting Started Outputs Key The Outputs key turns all signal outputs on or off when the generator is in normal operating mode. This is the master output signal control. When the master output control is turned off, all of the signal outputs (video and sync) of the generator are disabled. Key Function Command ON Toggles on and off all video and sync. OUTG LCD The generator displays format and image information on the LCD in either of these modes: • Default display mode: This mode displays an index sequence number left of the current format and current image. The image version number, which appears on the display,represents a version of a image that has multiple versions associated with it. Horizontal rate Format index H32 V60 Vertical rate • Format name 150=DMT0660 250=SMPTE133 Image index Image name Status Display mode: This mode replaces the index numbers with codes, which provide additional information about the active format. This mode is useful when working with multiple video signal outputs and color encoding methods. Color space Color depth Video type H31 V60 Format name D8C=DMT0659 0=SMPTE133 Image version Image name Video types: • A for analog video • D for DVI video • H for HDMI video Color depths: • 4 for 4-bits per pixel depth • 8 for 8-bits per pixel depth Color space: 802BT/802R Video Test Generator User Guide 7 • M for monochrome video • C for RGB color video • Y for YPrPb (analog) or YCrCb (digital) with 4:4:4 color sampling • y for YCrCb (digital) with 4:2:2 color sampling To use Status Display mode: 1. Turn off the generator. 2. Hold down the Step, G, and B keys while starting the generator, until status display displays. Special: keys Status display Alternatively, you can set the status display mode by entering the following command: SROP 8; ALLU Determining if the active format has been modified If the active format has not been modified from the factory setting, then the index number and format name are separated by an equal (=) character. If the active format has been modified, then the index number and format name are separated by a blank space. The blank space indicates that the active format has been modified from the default format definition. 8 Chapter 1 Getting Started Video interfaces This section describes the video interfaces available on the generator. VGA interface Use to output analog video for testing analog video displays. The following table describes the VGA connector pinouts. Pi Signal Pin Signal Pin Signal 1 Analog Red Video 6 Analog Red Video Ground 11 No Connection 2 Analog Green Video 7 Analog Green Video Ground 12 DDC/EDID Serial Data 3 Analog Blue Video 8 Analog Blue Video Ground 13 Horizontal Sync 4 No Connection 9 DDC/EDID +5 Vdc Out 14 Vertical Sync 5 Digital Ground 10 Digital Ground 15 DDC/EDID Data Clock DVI-I interface Use to output digital video for testing DVI-compliant video displays. Note that the DVI-I connector also provides an analog output which can be used to test analog formats with a VGA to DVI adapter when the generator is in analog friendly mode. The DVI connector pinouts are shown in the following table. Pin Signal Pin Signal Pin Signal Pin Signal 1 TMDS D2- 9 TMDS D1- 17 TMDS D0- C1 Analog Red 2 TMDS D2+ 10 TMDS D1+ 18 TMDS D0+ C2 Analog Green 3 D2/4 Shield 11 D1/3 Shield 19 D0/5 Shield C3 Analog Blue 4 TMDS D4- 12 TMDS D3- 20 TMDS D5- C4 Horizontal Sync 5 TMDS D4+ 13 TMDS D3+ 21 TMDS D5+ C5 Analog Ground 6 DDC Clock 14 +5 Vdc 22 Clock Shield 7 DDC Data 15 Ground 23 TMDS Clock+ 8 No Connection 16 Hot Plug Detect 24 TMDS Clock- 802BT/802R Video Test Generator User Guide 9 LVDS interface The LVDS connector is located on the front of the generator and is labeled “Digital.” It emulates a digital host video source and is used for testing LVDS-compliant video displays. The LVDS connector pinouts are shown in the following table. Pin Signal Pin Signal Pin Signal Pin Signal 1 A0M 10 DDC Clock 19 A0P 28 DDC Data 2 A1M 11 DDC +5 Vdc 20 A1P 29 USB Ground 3 A2M 12 USB+ 21 A2P 30 USB- 4 Clock 1M 13 USB +5 Vdc 22 Clock 1P 31 Shield Ground 5 A3M 14 A4M 23 A3P 32 A4P 6 Shield 15 A5M 24 No Connection 33 A5P 7 No Connection 16 A6M 25 No Connection 34 A6P 8 No Connection 17 A7M 26 No Connection 35 A7P 9 No Connection 18 Clock 2M 27 DDC Ground 36 Clock 2P HDMI interface The HDMI connector is located on the front of the generator and is labeled “HDMI.” It emulates an HDMI-compliant video display. The HDMI connector pinouts are shown in the following table. HDMI Type A Connector Pinouts (HDMI option only) Pin Signal Pin Signal Pin Signal 1 TMDS Data 2+ 7 TMDS Data0+ 13 CEC 2 TMDS Data2 Shield 8 TMDS Data0 Shield 14 Reserved (N.C.) 3 TMDS Data2- 9 TMDS Data0- 15 SCL 4 TMDS Data1+ 10 TMDS Clock+ 16 SDA 5 TMDS Data1 Shield 11 TMDS Clock Shield 17 DDC/SEC Ground 6 TMDS Data1- 12 TMDS Clock- 18 +5 V Power Special Sync (S/S) interface Use the S/S connector to output frame sync, line sync, composite sync, or a special probe pulse. For more information, see Chapter 12, “Using Special Sync Output.” S-Video interface If you have chosen the TV option your generator will have an S-Video connector on the right side labeled “SVIDEO.” This is a miniDIN connector that emulates an S-Video compliant source for outputting composite TV signal. 10 Chapter 1 Getting Started Composite video BNC If your generator is equipped with the TV option, it will have a composite TV BNC connector on the right side, labeled “TV.” This interface emulates an analog composite TV source. Component video BNC interface Your generator can be optionally equipped with separate R. G, B, HS/CS, and VS BNC connectors on the right side. These interfaces emulate component a analog video source. 802BT/802R Video Test Generator User Guide 11 Computer interfaces This section describes the RS-232, GPIB, and USB interfaces. RS-232 interface Each generator has a standard RS-232 serial connector, labeled “Serial.” This is a 9-pin D-Sub male connector which enables you to connect the generator with a computer. A null modem cable is provided to support this interface. You can communicate with the generator either through the command line interface from a telnet session or from the Video Generator Manager (VGM) application. The pinouts for the RS-232 connector are shown in the following table. Pin Signal Pin Signal Pin Signal 1 Data Carrier Detect 4 Data Terminal Ready 7 Request to Send 2 Received Data 5 Signal Ground 8 Clear to Send 3 Transmitted Data 6 Data Set Ready 9 Ring Indicator GPIB interface (optional) The GBIP interface allows you to use the generator as a programmable video signal source in a larger automated test system. Generators that have the GPIB interface option have two rotary switches for setting the GPIB address. These switches are accessible through the ventilation slots. The GPIB connector pinouts are listed in the following table. Pin Signal Pin Signal Pin Signal Pin Signal 1 DIO1 7 NRFD 13 DIO5 19 Shield 2 DIO2 8 NDAC 14 DIO6 20 Shield 3 DIO3 9 IFC 15 DIO7 21 Shield 4 DIO4 10 SRQ 16 DIO8 22 Shield 5 EOI 11 ATN 17 REN 23 Shield 6 DAV 12 Shield 18 Shield 24 Signal Ground USB interface Use the USB interface for downloading bitmap images from a computer. With VGM 4.0 or later, the USB interface can be used in place of the serial interface. 12 Chapter 1 Getting Started PCMCIA interface Use the PCMCIA card slot to back up your custom configurations, transfer configurations and settings from one generator to another, and store bitmap images. 802BT/802R Video Test Generator User Guide 13 Command interfaces The common test applications can be accomplished through the physical controls or through the command line interface. The generator supports an ASCII command and query language that allows you to control the generator interactively or through batch processing of command files. All generator functions are supported through this interface. The command interface is available through two physical interfaces: the RS-232 interface and the optional IEEE-488 GPIB interface. The GPIB interface supports programmatic control in an automated test environment, which is discussed in more detail in Chapter 7, “Using GPIB Interface.” This interface also supports user interactive command sessions. The procedures for using the RS-232 interface are explained in this section. Setting up a terminal connection with the generator The following procedures describe how to setup a terminal session with the generator using the RS-232 interface. To setup a terminal connection with the generator: Whenever the generator is powered on, the baud rate returns to 2400 bps, no parity, 8 data bits, 1 stop bit, and no handshake. 1. Connect the RS-232 cable between your computer or terminal and the serial connector on the generator. 2. Using a terminal emulator, such as HyperTerminal, establish a terminal connection with the generator. Configure the terminal emulator to use the following parameters: • 2400 baud rate • 8 data bits • 1 stop bit • no parity • no handshaking • full duplex 3. Press the Enter key until the R:> prompt appears. 14 Chapter 1 Getting Started Changing the baud rate The RS-232 interface can be configured from the physical controls to support faster baud rates and to supprort a remote keypad (optional accessory). The default configuration is 2400 baud. When the generator is powered on, the baud rate returns to the default configuration. To support file transfers, you can change the baud rate of the port to 38400 bps using the command line interface or 9600 bps using the physical controls. To increase the baud rate using the command line interface: 1. At the R:> prompt, enter the following command: MODE 38400 n, 8, 1, h, n After you press Enter, the terminal emulator will lose its connection with the generator, which is now set at a different baud rate. 2. Close the terminal emulator session, change the baud rate to 38400, and then re-open the session, specifying the baud rate as 38400. To change the baud rate to 9600 using the front panel: 1. Turn off the generator. 2. Hold down the R and DCS keys while starting the generator. The serial port is now set to 9600 bps. Restarting the generator again, without pressing any keys, will Sending commands interactively This procedure describes how to send commands through an interactive user session. The generator parses command lines one at a time. Command lines must be terminated with a carriage return (). The generator immediately echoes each character as it is received and places it in a command line buffer. When sending multiple commands at once, separate each command with a semi-colon. Commands are not case sensitive. To send single commands to the generator: 1. Establish a terminal session with the generator (see page 14). 2. At the R:> prompt, enter commands or queries and terminate with a carriage return. Command examples • To display the name of the format currently in the format buffer, enter: FMTL? • To load a format, enter: FMTL format_name 802BT/802R Video Test Generator User Guide 15 • To apply the format to the generator hardware, enter: FMTU • To load an image, enter: IMGL image_name • To apply the image to the generator hardware, enter: IMGU To send multiple queries and commands to the generator: 1. Establish a terminal session with the generator (see page 14). 2. At the R:> prompt, enter the queries or commands, separating each with a semi-colon and terminating the command line with a carriage return. Command examples: • To query the current format and then load a new format enter the following: FMTL?; FMTL new_format; FMTL? FMTU The generator will return the following in response to this command and query string: current_format; new_format • To change the format and image active in the generator enter: FMTL 480p59; IMGL SMPTEbar; ALLU This tells the generator to load the 480p59 format named “” into the format data buffer, the image named “SMPTEbar” into the image data buffer, and then to “use” the contents of both (“all”) buffers to drive the generator's output. Sending commands from text files When developing more complex, custom test sequences or formats, it is easiest to enter commands in a text file, and then send the file to the generator. This approach allows you to modify the file without entering the entire command script. To send a text file to the generator: 1. Using a text editor, enter the commands that define a test sequence or format into a text file, and save the text file using a *.txt extension. 2. Establish a terminal session with the generator (see page 14). 16 Chapter 1 Getting Started 3. At the R:> prompt, transfer the text file to the generator. For example, to transfer a file using HyperTerminal, do the following: a. On the Transfer menu, click Send Text File. The Send Text File dialog box appears. b. Select the text file you want to send, and then click Open. HyperTerminal displays the commands as they are sent. c. Press Enter once to ensure that the last command is sent. 802BT/802R Video Test Generator User Guide 17 Special operating modes You can set the generator to operate in various modes to accomplish specific functions. When any special operational mode is set, it persists (until overridden) throughout subsequent power cycles, which may be performed to set other modes. You can view the operational settings and special functions of the generator on a video display by viewing the GenOps image. This image provides key sequences and the status of special operating modes in the generator. To determine the status of operating modes: 1. Connect the appropriate interface cable to the video display. 2. Using the Format knob, select a format suitable for the display. 3. Turn the Image knob to select the GenOps image. 18 Chapter 1 Getting Started Summary of special modes The following table describes the special operating modes, and how to configure the modes using the physical controls or the command line interface. Special mode Function Physical control Initialize with factory defaults Re-initializes generator to fac- ACS, DSS tory defaults. Removes all special modes, deletes all custom objects. INIT Calibrate Calibrates the generator. SCAL R, G, B Command SROP 32 Clone Copies configuration settings from one generator to other generators using a PCMCIA card. Step, Outputs Set: SROP 64 Rst: SROP 0 64 Old format library Displays old format names on LCD. G Set: SROP 1 Rst: SROP 0 1 Remove all modes Removes all special modes. ACS, DCS, DSS Set: SROP 0 Set GPIB address Sets the GPIB address. DCS Set: GPIB addr Rst: INIT Set baud rate to 9600 Sets baud rate of RS-232 port to 9600 bps. Enable programmable keypad R, DCS Set: SROP 256 Rst: SROP 0 256 R, OUTPUT Set: SROP 512 Rst: SROP 0 512 Enable numeric keypad Enables remote operation through remote keypad. R Set: SROP 128 Rst: SROP 0 128 Analog friendly mode Causes all digital formats to output analog video signal. R, B Set: SROP 4 Rst: SROP 0 4 Enable status display Provides additional information on LCD (analog/digital and color depth). Step, G, B Set: SROP 8 Rst: SROP 0 8 DCS priority scheme Changes priority scheme for Step, DCS putting CS on separate VS and HS sync outputs when any digital composite sync (DCS) type is selected Set: SROP 4096 Rst: SROP 0 4096 Digital friendly mode Causes all analog formats out- G, B put digital signal Set: SROP 2 Rst: SROP 0 2 Color difference friendly Outputs digital YCbCr for television formats. B Set: SROP 2048 Rst: SROP 0 2048 Reset HDCP Rx gating clock Resets the receiver, and gates off transmitter clock and data. Outputs Set: SROP 16 Rst: SROP 0 16 802BT/802R Video Test Generator User Guide 19 Special mode Function Physical control Command HDCP tester mode Enables HDCP testing. G, ACS Set: SROP 8192 Rst: SROP 0 8192 Hot plug formats Auto-configures generator format knob list based on EDID in response to hot plug. R, ACS Set: SROP 16384 Rst: SROP 0 16384 DVI mode (disable HDMI) Outputs DVI on HDMI connector. R, G Set: SROP 32768 Rst: SROP 0 32768 Hot plug bypass Bypasses hot plug detection and auto-configuration of the generator. Step, R, ACS Set: SROP 65536 Rst: SROP 0 65536 Special key operations summary The following table describes modes that can be enabled while the generator is running, and the physical controls and comands for using the modes. 20 Physical control (hold 1st & press 2nd) Command Mode Function Toggle analog/digital Outputs either digital or analog. G, B Rotate video type Outputs either RGB, color difference, or monochrome. R, B DDC-based auto-configuration Auto-configures generator format knob list based on EDID. R, ACS Toggle biLevel/triLevel Toggles between tri-level and B, ACS bi-level syncs for analog HDTV formats with tri-level sync type. Chapter 1 Getting Started AVST x; DVST x TSPG x About Video Generator Manager Video Generator Manager (VGM) is a Microsoft Windows-based program used to operate the generator from a computer. VGM features VGM supports the following functions. • Creating custom test sequences. • Creating customized Image or Format knob lists. • Creating custom formats or modifying existing formats. • Creating custom images or modifying existing images. • Archiving custom data. • Upgrading the generator firmware. • Re-initializing a generator. • Calibrating a generator. • Downloading a bitmap image to a generator. 802BT/802R Video Test Generator User Guide 21 For information about using VGM, see the VGM online help. Installing VGM VGM is available on the Resource CD included with the generator, and from http://www.quantumdata.com/support/downloads/. To install VGM: 1. Log onto Windows with Administrator privileges. 2. Do one of the following: • On the Resource CD, double-click the setup.exe file to begin the installation. • On the Quantum Data Web site, click the setup.exe file to begin the installation. 3. Follow the on-screen instructions. 22 Chapter 1 Getting Started 2 Testing Video Displays Topics in this chapter: • General video display testing procedure • Testing analog computer (IT) CRTs • Testing digital computer (IT) FPDs • Testing analog composite video SDTV (CE) CRTs • Testing analog component video SDTV (CE) CRTs • Testing digital component video HDTV (CE) flat panel displays 802BT/802R Video Test Generator User Guide 23 General video display testing procedure This section provides an overview of the video testing process, which involves connecting the generator to the display under test, selecting a format appropriate for the display, and then selecting images to exercise the display to ensure proper functioning. Making physical connections Use the following table to connect the generator with display under test. Display type Signal type Cable Information Technology (IT) Computer - VESA (DMT, CVT) Analog component RGB VGA to VGA Computer - VESA DDWG Digital component RGB DVI to DVI Consumer Equipment (CE) SDTV - ITU-470-6 baseband Analog composite CVBS BNC to RCA 75 Ohm SDTV - ITU-470-6 baseband Analog composite S-Video S-Video (miniDin to MiniDin) SDTV - CEA-861B Analog component YPbPr VGA to RCA1 HDTV - CEA-861B Digital component DVI RGB DVI to DVI, or HDMI to DVI HDTV - CEA-861B Digital component HDMI RGB and YCbCr HDMI to HDMI 1. Optional cable available from Quantum Data. Setting the video output mode If the application involves testing similar displays with one type of video signal output for extended periods of time (for example, in a production environment), use one of the following modes: • Digital Friendly mode – Digital formats are output without change, while analog formats are temporarily switched to digital. This mode is available only if the generator has a digital option (DVI, LVDS, or HDMI) installed. • Analog Friendly mode – Analog formats are output without change, while the digital formats are temporarily switched to analog. For information about using these modes, see “Summary of special modes” on page 19. When you need to test various video signal outputs and color encoding methods (for example, in a repair center), disable all friendly modes, and enable the Status Display mode (see “LCD” on page 7) so that you can determine the current configuration. Then, 24 Chapter 2 Testing Video Displays hold down the G key while pressing and releasing the B key to switch between digital and analog outputs. The table below shows the AVST and DVST command settings for analog and digital outputs. Video Signal Interface AVST DVST Analog YYY Grayscale 1 0 Analog RGB Color 2 0 CVBS or S-Video Grayscale 3 0 CVBS or S-Video Color 4 0 Analog YPbPr SDTV Color 6 0 Analog YPbPr HDTV Color 7 0 Digital YYY Grayscale 0 9 Digital RGB Color 0 10 Digital YCbCr SDTVColor 0 13 Digital YCbCr HDTV Color 0 14 Selecting video formats This section explains how to configure the generator to output video formats that are supported by the device being tested. Note: You can create your own formats. See “Creating custom formats” on page 63 for details. Additionally, you can create your own Format knob lists. See “Editing Format knob lists” on page 67 for details. Selecting formats automatically When testing EDID-compatible displays, the generator can automatically update the Format knob list (list of format names shown on the LCD) to include only formats supported by the display under test. Depending on the output used, the generator can do this on demand, or automatically when a display is connected. To update the Format knob list on demand: 1. Connect the display you want to test with the generator. 2. Hold down the R key, and then press and release the ACS key. This puts the generator into either Analog Friendly or Digital Friendly mode based on the EDID that the generator receives. 3. Turn the Format knob to choose a format. Only formats supported by the display are listed. 802BT/802R Video Test Generator User Guide 25 To update the Format knob list automatically when a display is connected: 1. Connect the display you want to test with the DVI or HDMI connector on the generator. (Analog outputs do not support this feature.) 2. Turn the generator off. 3. Hold down the R and ACS keys while starting the generator, until hot plug formats displays on the LCD. Note: The generator is now in Digital Friendly mode. 4. Turn the Format knob to choose a format. Only formats supported by the display are listed. 5. Connect a different device to automatically update the Format knob list again. Selecting formats manually When testing a display that is not EDID-compliant, you must manually choose formats from the generator that are supported by the display. To do this: • Identifing the type of display (composite television, component standard definition television, component high definition television, computer equipment, or other specialty display). • Check the specifications of your display for supported formats. • Learn how the format library is organized, and how formats are named (see below). • Turn the Format knob to try formats from the appropriate format category. Try the DMT0660 (VGA) format if you are not sure of which formats to use. Understanding the format library After connecting the generator with the display under test, turn generator on, and select a video format. This section describes how to choose a video format, from the list of formats built into the generator, for the display you are testing. A format defines a set of video, timing and sync parameters for a specific device or standard. A summary of the format naming convention is provided. For a detailed description of the naming conventions, see to “Format naming conventions” on page 56. Organization of format library The generator has several built-in formats to test a broad range of display types. These formats are grouped in the following categories: 26 Chapter 2 Testing Video Displays • Composite television formats • Component standard definition television formats • Component high definition television • Computer display formats • Military and medical display formats • Miscellaneous formats When you turn the Format knob, the formats are listed in the order shown above. Composite television formats Composite television formats are named by the standards defining them. The first three to five characters of the format name indicate the color coding scheme. The first set of characters refers to the standard. The next characters are optional and indicate adjustments to the format. Examples of these formats are: • NTSC (North American TV) • PAL (European TV) • NTSC-J - (where J refers to a Japan standard per NTSC without 7.5 IRE setup) • PAL-N (where N indicates 3.58205625 MHz color sub-carrier) • PAL# (where # indicates that the sampling rate is reduced to achieve square pixels) Component standard definition television formats Component SDTV formats are applicable in the case of RGB, YPbPr. These formats are named by their vertical resolution, scanning method, and frame rate. The initial characters indicating the resolution are followed by the scanning method. The two characters following the scanning method indicate the frame rate. A typical example of component standard or definition TV video format is: • 480i2x30 (for a vertical resolution of 480 pixels with interlaced scanning and a 30 Hz frame refresh rate; 2x indicates that the pixels are double-clocked for DVI compatibility). Component high definition television formats Component high definition television formats, like the standard definition television formats, are named by their vertical resolution, scanning method, and frame rate. These formats are applicable in the case of RGB, YPbPr, and YCbCr. These initial characters indicating the resolution are followed by the scanning method. The two characters following the scanning method indicate the frame rate. A typical example of component high definition TV video format is: • 1080i30 (for a vertical resolution of 1080 active vertical lines with interlaced scanning and a 30 Hz frame refresh rate). 802BT/802R Video Test Generator User Guide 27 Computer display formats Computer display formats are assumed to use progressive scanning. Computer format names consist of four blocks. The initial three characters indicate the vendor ID using the EISA ID (for example, IBM, SUN, and VSC) or the standard body or acronym (for example, SMT, DMT, GTF, CEA, and EIA). The next two characters provide the first two digits of the horizontal resolution in pixels. Following the horizontal resolution are two characters which indicate the frame rate. The final character indicates the aperture, which is used only if the aperture is not 1.33 (A). The following are examples of computer display formats: • VSC1275 for Viewsonic 1280 by 1024 at 75 Hz • DMT0685 for Discrete Monitor Timing with 680 by 480 at 85 Hz Viewing format parameters You can use the Format image or VGM to view detailed information about formats in the generator. To view formats parameters using VGM: • Open each format in the Font Editor. • Generate a detailed format listing. Refer to the VGM online help for instructions. Selecting images Once you have determined the format or formats appropriate for testing the display you will apply a series of images suitable for evaluating the display. Of primary importance is determining what type of display you are testing (for example, CRT or digital flat panel display). You must also determine if you are testing composite TV and use images appropriate for these formats and video types. Each image in the generator’s library is intended to test one or more attributes of a particular display type and video type. Note: You can create your own images. See “Creating custom images” on page 75 for details. Additionally, you can create your own custom Image knob lists. See “Editing Image knob list” on page 81 for details. 28 Chapter 2 Testing Video Displays The table below provides a summary of display characteristics and the images used to evaluate them. For details on the images and display attributes, see Appendix B, “Image Reference.” Display type Display test Recommended images Analog CRT Geometry (pin and barrel, linearity) Static images Hatch (TVHatch, Hatch_16, Hatch_20), CirclesL, Geom_1 - Geom_5, SMPTE133 Focus Focus_@6, Focus_@7, Focus_@8, Focus_@9, Text_9, Text_9T, Text_11, Text_12T, Text_16 Photometry (chrominance, contrast, levels) Flat, Flat07, Flat13, Flat20, Flat27, Flat33, Flat40, Flat47, Flat53, Flat60, Flat67, Flat73, Flat80, Flat87, Flat93, FlatGray, Flat_01, Flat_02, Flat_03, Flat_04, Flat_05, Flat_06, Flat_07, Flat_08, Flat_09, Flat_10, Flat_11, Flat_12, Flat_13, Flat_14, Flat_15, Flat_16, Ramp_B, Ramp_G, and Ramp_R, ColorBar, SMPTEbar, TVBar100 & TVBar_75 (TV formats only) Luminance SMPTE133 (grayscale), Grays5, Grays9, Grays11, Grays16, Grays32, Grays64 Gamma correction SMPTE133 (checkerbox) Resolution BurstTCE, Burst (TV formats only), Grill_11, Grill_15, Grill_22, Grill_33, Grill_44 Pulse (CE SDTV) PulseBar Centering Outline0, Outline1, Outline2, Outline3 Voltage Regulation Regulate Electromagnetic Interference EMITest1, EMITest2, EMITest3, EMITest4, EMITest5 802BT/802R Video Test Generator User Guide 29 30 Display type Display test Recommended images Digital flat panel (fixed pixel display) Pixel anomalies (stuck pixels, misc sampling) Flat, Raster, Ramp_B, Ramp_G, and Ramp_R, Focus_@6, Focus_@7, Focus_@8, Focus_@9, Text_9, Text_9T, Text_11, Text_12T, Text_16 Photometry (chrominance, contrast, levels) Flat, Flat07, Flat13, Flat20, Flat27, Flat33, Flat40, Flat47, Flat53, Flat60, Flat67, Flat73, Flat80, Flat87, Flat93, FlatGray, Flat_01, Flat_02, Flat_03, Flat_04, Flat_05, Flat_06, Flat_07, Flat_08, Flat_09, Flat_10, Flat_11, Flat_12, Flat_13, Flat_14, Flat_15, Flat_16, Ramp_B, Ramp_G, and Ramp_R, ColorBar, SMPTEbar, SMPTE133 Luminance SMPTE133 (grayscale), Grays5, Grays9, Grays11, Grays16, Grays32, Grays64 Centering Outline0, Outline1, Outline2, Outline3 Resolution BurstTCE, Grill_11, Grill_15, Grill_22, Grill_33, Grill_44 Persistence Animated images: Persist, Cubes, SlideX Chapter 2 Testing Video Displays Testing analog computer (IT) CRTs This section describes how to test analog computer (IT) displays. To test an analog computer CRT: 1. Use a standard VGA cable to connect the VGA connector on the generator with the VGA connector on the display under test. 2. Calibrate the generator by holding down the R, G and B keys while starting the generator. See “Calibrating the generator” on page 47. You can also calibrate the generator by entering the following command: SCAL When calibrating the generator, if you load the analog outputs (as they will be loaded when conducting testing) then the calibrations will be slightly more accurate. This is not required however. Also, loading the unused outputs with 75 ohms will optimize signal damping. 3. (Optional) Enable the Status Display mode and Analog Friendly mode (see “Special operating modes” on page 18). The Analog Friendly mode ensures that the generator will output an analog signal. The Status Display mode enables you to view the current output characteristics on the LCD. 4. Determine the formats to test (see “Selecting formats automatically” on page 25). 5. (Optional) To view the EDID on the display, use the Image knob to select the EdidData image and follow the directions on the display. You may wish to view the EDID data to verify that the formats required for testing are specified in the EDID. Alternatively, you can load the image with the following command: IMGL EdidData; IMGU 6. Determine additional formats to test based on the resolution of the display. The VESA formats are shown below: Standard Quantum Data format name VGA DMT06xx SVGA DMT08xx XGA DMT10xx SXGA DMT12xx UXGA DMT16xx QXGA DMT20xx QSXBA DMT25xx 802BT/802R Video Test Generator User Guide 31 Determine the images to test: For analog CRTs you typically want to select images to test for geometry, focusing, photometry, resolution, cross talk, EMI, and regulation characteristics. For more details on what images test these specific display attributes, see “Selecting images” on page 28 or Appendix B, “Image Reference.” Verify the test set-up: 1. Using the Format knob, select one of the formats you have identified. Alternatively, you can load the format with the following command: FMTL format_name; FMTU 2. Using the Image knob, select a suitable image such as ColorBar. Verify that the display is presenting the image to ensure that the generator is sending a valid signal to the display. Alternatively, you can load the image with the following command: IMGL ColorBar; IMGU Test the display: 1. Using the Format knob, select the first test format identified. Alternatively, use these commands to load the format: FMTL format_name; FMTU 2. Using the Image knob, select the first test image. Alternatively, you can also load an image with the following command: IMGL image_name; IMGU 3. Repeat steps 1 and 2 for all formats and test images. Use the following guidelines to verify proper operation: 32 • When testing geometry with the Hatch images (for example, Hatch20) look for distortion with concave or convex lines near the periphery of the display. Look for irregular spacing on the cross hatch patterns. • When testing photometry such as chrominance, use the ColorBar, SMPTE133, or SMPTEbar images. Look for missing bars which may indicate a dead or unconnected channel. Also, look at the transition between the bars; they should be sharp and distinct. Each bar also should be uniform in color and intensity across its entire width. • To test luminance, you can use the SMPTE133 (grayscale portion) image. To test gamma correction, you can use the SMPTE133 (checkerbox portion) image. The detailed methods for verifying these parameters on the SMPTE133 image are provided in Appendix B, “Image Reference.” • When testing focus with the Focus or Text images, the characters in all areas of the display should be well-formed and in focus. Chapter 2 Testing Video Displays • When testing resolution with the Grill images, you should be able to see individual and distinct stripes in all areas of the display at all four resolutions. • When testing for centering use the Outline images. For detailed methods for verifying centering with the Outline images, see Appendix B, “Image Reference.” • When testing for high voltage regulation with the Regulate image, observe the outline at the edges of the image. They should stay in place and not pull away from the area of the large white blinking patch (when it appears). Note: You can customize your generator to run through a specified set of formats and images automatically or manually by creating test sequences. See to “Creating a test sequence” on page 87 for details. 802BT/802R Video Test Generator User Guide 33 Testing digital computer (IT) FPDs This section describes how to test digital computer (IT) displays. To test a digital FPD: 1. Use a DVI-I cable to connect the DVI output on the generator with the DVI connector on the display under test. 2. Place the generator in Digital Friendly mode by holding down the G and B keys while starting the generator. Alternatively, you can set the Digital Friendly mode by entering the following command: SROP 2 4; ALLU The Digital Friendly mode ensures that the generator will output a digital signal on the DVI connector, when selecting analog formats from the format library. 3. Determine the formats to test. Auto-select the formats to test by enabling the generator’s DDC-based auto configuration. See “Selecting formats automatically” on page 25 for instructions. 4. (Optional) To view the EDID on the display, use the Image knob to select the EdidData image and follow the directions on the display. Verify that the EDID specifies the formats required for testing. Alternatively, you can load the image with the following command: IMGL EdidData; IMGU 5. Determine which images to test. For digital flat panel displays, you typically want to select images to test for pixel anomalies, persistence, photometry and resolution related problems. For more information, see “Selecting images” on page 28 or Appendix B, “Image Reference.” Verify the test set-up: 1. Using the Format knob, select one of the formats you have identified. Alternatively, you can load the format with the following command: FMTL format_name; FMTU 2. Using the Image knob, select a suitable image such as SMPTE133. Verify that the display is presenting the image to ensure that the generator is sending a valid signal to the display. Alternatively, you can load the image with the following command: IMGL SMPTE133; IMGU Test the display: 1. Using the Format knob, select the first test format identified. 34 Chapter 2 Testing Video Displays 2. Using the Image knob, select the first test image. 3. Repeat steps 1 and 2 for all formats and test images. Use the following guidelines to verify proper operation: • When testing photometry such as chrominance, use the ColorBar, SMPTE133, or SMPTEbar images. Look for missing bars which may indicate a dead or unconnected channel. Also, look at the transition between the bars; they should be sharp and distinct. Each bar also should be uniform in color and intensity across its entire width. • To test luminance, you can use the SMPTE133 (grayscale portion) image. To test gamma correction, you can use the SMPTE133 (checkerbox portion) image. The detailed methods for verifying these parameters on the SMPTE133 image are provided in Appendix B, “Image Reference.” • When testing for centering use the Outline images. The detailed methods for verifying centering with the Outline images (Outline0, Outline1, Outline2, Outline3) are provided in Appendix B, “Image Reference.” • When testing resolution with the Grill images, you should be able to see individual and distinct stripes in all areas of the display at all four resolutions. • When testing for pixel anomalies use the Flat, Raster and Ramp images. Use the Raster and Flat images to look for pixels that may be stuck On or Off, respectively. The luminance should increase uniformly for the Ramp image. Also, look for sparkles indicating problems with sampling. • When testing for persistence with the animated images (for example, Cubes and Persist), look for bleeding or trails in the wake of the moving object. Note: You can customize your generator to run through a specified set of formats and images automatically or manually by creating test sequences. See “Creating a test sequence” on page 87 for details. 802BT/802R Video Test Generator User Guide 35 Testing analog composite video SDTV (CE) CRTs This section describes how to test CRT composite televisions with analog composite video inputs. To test analog composite video SDTV: 1. Use a standard coax cable to connect the TV BNC connector on the generator with the display under test. Or, use an S-video cable to connect the SVIDEO connector on the generator with the S-Video input on the display under test. 2. (Optional) Place the generator in Analog Friendly mode by holding down the R and B keys while starting the generator (see “Special operating modes” on page 18). The Analog Friendly mode ensures that the generator will output an analog signal. 3. Determine which composite television standard you need, such as NTSC or PAL, and then select the formats compatible with the standard. Typically, you would test all the formats in the family of formats for a standard. 4. Determine the images to test. For analog CRTs you typically want to select images to test for geometry, focusing, photometry, resolution, cross talk, EMI, and regulation characteristics. For more details on what images test these specific display attributes, see “Selecting images” on page 28 or Appendix B, “Image Reference.” Verify the test set-up: 1. Using the Format knob, select the first NTSC or PAL format. Alternatively, you can load the format with the following command: FMTL format_name; FMTU 2. Using the Image knob, select a suitable image such as SMPTEBar. Verify that the generator is sending a valid signal to the display and that the display is presenting it. Alternatively, you can load the image with the following command: IMGL SMPTEBar; IMGU Test the display: 1. Using the Format knob, select the first test format. 2. Using the Image knob, select the first test image. Note: You can customize your generator to run through a specified set of formats and images automatically or manually by creating test sequences. See “Creating a test sequence” on page 87 for details. 3. Repeat steps 1 and 2 for all formats and test images. Use the following guidelines to verify proper operation: 36 Chapter 2 Testing Video Displays • When testing geometry with the Hatch images (for example, TVHatch and Hatch20) look for distortion with concave or convex lines near the periphery of the display. Look for irregular spacing on the cross hatch patterns. • When testing photometry such as chrominance, use the TVBar100 & TVBar_75 (TV formats only), TVSplBar, SMPTE133 or SMPTEbar images. Look for missing bars which may indicate a dead or unconnected channel. Also, look at the transition between the bars; they should be sharp and distinct. Each bar also should be uniform in color and intensity across its entire width. • When testing focus with the Focus images, the characters in all areas of the display should be well-formed and in focus. • When testing resolution with the Grill images, you should be able to see individual and distinct stripes in all areas of the display at all four resolutions. When testing for resolution with the Burst image, the peak intensities of the all of the bursts should match the white reference level. The darkest portions between the peaks should match the black reference level. • When testing for centering, use the Outline and TVoutLin images. The detailed methods for verifying centering with the Outline images (Outline0, Outline1, Outline2, Outline3) are provided in Appendix B, “Image Reference.” • When testing for high voltage regulation with the Regulate image, observe the outline at the edges of the image. They should stay in place and not pull away from the area of the large, white blinking patch (when it appears). 802BT/802R Video Test Generator User Guide 37 Testing analog component video SDTV (CE) CRTs This section describes how to test CRT televisions with standard definition component video inputs. To test an analog component video SDTV display: 1. Use a VGA-to-RCA cable to connect the VGA connector on the generator with the YPbPr inputs on the display under test. Or, if your generator has optional component BNC connectors, use a BNC to RCA cable to connect the BNCs on the generator with the RCA connectors on the display under test. 2. Identify the component television formats to test. These formats are listed after the composite television formats in the generator’s default Format knob list. Begin with the first format in the range of standard definition component television formats (480i). 3. Determine additional formats to test based on the resolution of the television display. The television specification sheet will provide information on what resolutions to test. It is necessary to test only those resolutions with the supported scanning type (typically, interlaced for a standard definition television). 4. Determine the images to test. For analog CRTs you typically want to select images to test for geometry, focusing, photometry, resolution, cross talk, EMI, and regulation characteristics. For more details on what images test these specific display attributes, see “Selecting images” on page 28 or Appendix B, “Image Reference.” Verify the test set-up: 1. Using the Format knob, select the first component video format (480i). Alternatively, you can load the format with the following command: FMTL 480i; FMTU 2. Using the Image knob, select a suitable image such as SMPTE133. Verify that the generator is sending a valid signal to the display and that the display is presenting it. Alternatively, you can load the image with the following command: IMGL SMPTE133; IMGU Test the display: 1. Using the Format knob, select the first test format. 2. Using the Image knob, select the first test image. Note: You can customize your generator to run through a specified set of formats and images automatically or manually by creating test sequences. See “Creating a test sequence” on page 87 for details. 38 Chapter 2 Testing Video Displays 3. Repeat steps 1 and 2 for all formats and test images. Use the following guidelines to verify proper operation: • When testing geometry with the Hatch images (for example, TVHatch and Hatch20), look for distortion with concave or convex lines near the periphery of the display. Look for irregular spacing on the cross hatch patterns. • When testing photometry such as chrominence, use the TVBar100 & TVBar_75 (TV formats only), ColorBar, SMPTE133 or SMPTEbar images. Look for missing bars which may indicate a dead or unconnected channel. Also, look at the transition between the bars; they should be sharp and distinct. Each bar also should be uniform in color and intensity across its entire width. • To test luminance you can use the SMPTE133 (grayscale portion) image. To test gamma correction you can use the SMPTE133 (checkerbox portion) image. The detailed methods for verifying these parameters on the SMPTE133 image are provided in Appendix B, “Image Reference.” • When testing focus with the Focus or Text images, the characters in all areas of the display should be well-formed and in focus. • When testing resolution with the Grill images, you should be able to see individual and distinct stripes in all areas of the display at all four resolutions. • When testing for centering use the TVOutline and Outline images. The detailed methods for verifying centering with the Outline images (Outline0, Outline1, Outline2, Outline3) are provided in Appendix B, “Image Reference.” • When testing for high voltage regulation with the Regulate image, observe the outline at the edges of the image. They should stay in place and not pull away from the area of the large white blinking patch (when it appears). 802BT/802R Video Test Generator User Guide 39 Testing digital component video HDTV (CE) flat panel displays This section describes how to test digital component video for HDTV flat panel displays. To test a digital (DVI) component video HDTV display: 1. Use a standard DVI cable to the DVI connector on the generator and then to the DVI connector on the television display under test. Note: If the display under test has a DVI-D connector you will need a DVI-I to DVI-D adaptor. 2. Place the generator in Digital Friendly mode by holding down the G and B keys while starting the generator (see “Special operating modes” on page 18). This mode ensures that the generator outputs a digital signal on the DVI connector, even when selecting analog formats from the format library. 3. Identify the high definition component television formats to test. These formats are listed after the composite television formats in the generator’s default Format knob list. Begin with the first format (720p) in the range of high definition component television formats. See “Selecting formats automatically” on page 25. 4. Determine additional formats to test based on the resolution of the television display. The television product specification sheet will provide information on what resolutions to test. It is necessary to test only those resolutions with the supported scanning type (typically interlaced for a high definition television). 5. Determing which images to test. For digital television flat panel displays, you would typically want to select images to test for pixel anomalies, persistence, photometry and resolution related problems. For more details on which images test these specific display attributes, see “Selecting images” on page 28 or Appendix B, “Image Reference.” Verify the test set up: 1. Using the Format knob, select the first HDTV video format (720p50). Alternatively, you can load the format with the following command: FMTL 720p50; FMTU 2. Using the Image knob, select a suitable image such as the SMPTE133 image. Verify that the generator is sending a valid signal to the display and that the display is presenting it. Alternatively, you can load the image with the following command: IMGL SMPTE133; IMGU 40 Chapter 2 Testing Video Displays Test the display: 1. Using the Format knob, select the first test format. 2. Using the Image knob, select the first test image. Note: You can customize your generator to run through a specified set of formats and images automatically or manually by creating test sequences. See “Creating a test sequence” on page 87 for details. 3. Repeat steps 1 and 2 for all formats and test images. Use the following guidelines to verify proper operation: • When testing photometry such as chrominence, use the ColorBar, SMPTE133, or SMPTEbar images. Look for missing bars which may indicate a dead or unconnected channel. Also, look at the transition between the bars; they should be sharp and distinct. Each bar also should be uniform in color and intensity across its entire width. • To test luminance, you can use the SMPTE133 (grayscale) images. To test gamma correction, you can use the SMPTE133 (checkerbox) image. The detailed methods for verifying these parameters on the SMPTE133 Image are provided in Appendix B, “Image Reference.” • When testing for centering, use the Outline images. The detailed methods for verifying centering with the Outline images (Outline0, Outline1, Outline2, Outline3) are provided in Appendix B, “Image Reference.” • When testing resolution with the Grill images, you should be able to see individual and distinct stripes in all areas of the display at all four resolutions. • When testing for pixel anomalies, use the Flat, Raster, and Ramp images. Use the Raster and Flat images to look for pixels that may be stuck On or Off, respectively. The luminance should increase uniformly for the Ramp image. Also look for sparkles indicating problems with sampling. • When testing for persistence with the animated images (Cubes and Persist), look for bleeding or trails in the wake of the moving object. 802BT/802R Video Test Generator User Guide 41 42 Chapter 2 Testing Video Displays 3 Administrative Tasks The chapter describes how to accomplish common administrative tasks. Most administrative functions are supported through the front panel or command line interface. However, upgrading firmware can only be achieved through VGM; it is not supported through the front panel. Most administrative functions are supported through the VGM application. See the VGM online help for information on performing these administrative tasks through VGM. Topics in this chapter: • Displaying system information • Restoring factory settings • Calibrating the generator • Cloning generators • Installing firmware • Memory management 802BT/802R Video Test Generator User Guide 43 Displaying system information Use the GenStats image to display information about the generator, including revision levels of FPGA software installed. This image also list installed options. To display information about generator: 1. Connect the generator with a display. 2. Choose a format supported by the display. 3. Turn the Image knob to select the GenStats image. 44 Chapter 3 Administrative Tasks Restoring factory settings This section describes how to set and restore the generator system parameters. System Parameters The following system parameters are stored in the 802’s non-volatile system memory: • The reference rate calibration factor. The 802 uses a crystal controlled oscillator as the reference for all timing signals. The crystal frequency has a maximum error of ±50 ppm. The 802 hardware and firmware is capable of compensating for this small amount of error by applying a user set calibration factor. The factory default setting is 1.000 for the calibration factor. Use the RATC command to set the pixel calibration factors. • The maximum pixel clock rate used for error checking formats. All 802 generators will operate, to some extent, at pixel rates beyond their spec sheet limits. The maximum rate can be set to a higher limit if it is known that a particular unit will work reliably at the higher limit. Use the JRAT command to set the maximum pixel rate used for error checking of analog formats. • The gamma correction flag. This flag determines whether individual formats can control the application of gamma correction or if gamma correction is disabled regardless of a format’s setting. The factory default setting is to allow gamma correction to be controlled by individual formats. Use the GAMC command to enable or disable the gamma correction flag. Setting and restoring system parameters There are two ways of changing the settings of these parameters: • They can be restored to their default factory settings as part of a user initiated system reset. This will also restore the entire format storage memory to its factory default contents. • A suitably equipped computer or terminal connected to one of the communications ports can be used to set the parameters to user defined settings. When the generator is reinitialized, each format in the standard library is tested (one-at-a-time), to determine if the format parameters are fully supported by the generator. This algorithm is necessary because the standard format library is used across all generators. If there are some limitation the generator applies a format justification algorithm. In these cases the generator stores a modified version of the format under a similar name. If the format is beyond what can be corrected the format is left out of the generator’s list of formats. WARNING: The initializing the generator permanently and irreversibly removes all user-created formats, custom images, test sequences and directories from memory. 802BT/802R Video Test Generator User Guide 45 To re-initialize generator through system reset: 1. Hold down ACS and DSS while powering up the generator. A confirmation message is displayed. 2. Press the Outputs key to continue, or press the Step key to cancel the operation. To re-initialize and calibrate the generator using command interface: 1. Establish a terminal session with the generator (see page 14). 2. Enter the following command: INIT The generator then goes through a complete self-test and self-calibration procedure. To re-initialize without calibrating the generator using the command line: 1. Establish a terminal session with the generator (see page 14). 2. Enter the following command: BOIT The generator is re-intialized. 46 Chapter 3 Administrative Tasks Calibrating the generator The 802BT/R generator can calibrate itself. Once calibrated, the generator does not require periodic calibration. There are no physical controls to adjust. All calibration is electronic. Calibration factors are saved in non-volatile memory. The calibration accuracy of the generator for analog video voltage swing is specified to be ±14mV (or ±2% for a nominal 700mV signal). Using a typical oscilloscope such as a Tektronix VM700T, which might have a swing measurement accuracy of ±14mV, we should expect readings between 674mV to 726mV. You can also set the analog output calibration factors to values other than those set by the generator's own self-calibration function. Each channel is calibrated using two independent zero calibration points, and two independent slope calibration points. Interpolation equations for the different video types are used to set the caldac values that controls the output sync and voltage levels to the correct values. Follow the procedures below to calibrate the generator. To self-calibrate the generator using the front panel: 1. It is not necessary to load the outputs of a generator during self-calibration. However, attaching a nominal load may yield a slight increase in accuracy. 2. Simultaneously depress all three R, G and B video gate keys and power cycle the generator. The LCD will display a special message indicating that it is about to do a self-calibration. 3. Release the R, G and B video gate keys and the generator will begin its self-calibration routine. You will see calibration factors flash on the display. Observe the display for any error messages that might occur. If an error message appears, make a note of it and call your technical support representative for further assistance. To self-calibrate the generator using the command interface: 1. Establish a terminal session with the generator. See “Setting up a terminal connection with the generator” on page 14. 2. Enter the following command: SCAL The generator then goes through a complete calibration procedure. To view analog calibration factors: 1. Enter the following commands to view the analog video Red, Green, Blue calibration factors: 802BT/802R Video Test Generator User Guide 47 CALF? The generator presents the following in response: 1089, 2589, 1993, 3223, 1148, 2633, 2059, 3279, 1000, 2505, 1990, 3219, 793, 787, 3382, 3509 Calibrating frequency All frequencies associated with the generator are derived from a common frequency reference, which can be calibrated using the rate calibration command RATC. To reduce all frequency errors to zero: 1. Measure any convenient frequency from the generator using a very accurate frequency counter. For example, measure the horizontal TTL separate sync frequency with the DMT0660 format loaded and the horizontal rate temporarily set to 100KHz. Enter the following: FMTL DMT0660; HRAT 100E3; ALLU 2. Measure the TTL horizontal sync frequency with the frequency counter. 3. Divide the frequency that you expect by the frequency that you measure on the frequency counter and enter that ratio using the RATC command. For example, if you measure 99.9955782499875 kHz, when you expect 100.000000000KHz, then divide 100.000000000KHz by 99.9950002499875kHz and enter the following on the command line: RATC 1.0000442194553987 This will raise all frequencies output by the generator and make them exact. 48 Chapter 3 Administrative Tasks Cloning generators This section describes how to copy configuration settings from one generator to other generators using a PCMCIA card. The entire block of battery backed user memory (including video formats, custom test images and test sequences) is copied from one generator to another using a suitable PCMCIA memory card. The card you need is a Type 1, Battery Backed RAM PCMCIA card with at least 2 MB of storage. These cards are available from synchrotech P/N PCM-SRW-AM002 2MB. Flash or compact type memory cards will not work. Note: See VGM online help for procedures for cloning generators using VGM. To clone a generator using PCMCIA card: 1. Install the same firmware version on the source and target generators. Note: This procedure can only be used when the firmware of the source and target generators are the same. To verify the firmware version, load the GenStats image. 2. Insert PCMCIA card into the source generator. 3. Hold down the Step and Outputs keys while starting generator. 4. Choose WR (press Outputs key) to copy the generator configuration to the card. The generator displays a Done message when it is done writing to the card. 5. Transfer the PCMCIA card to the second generator. 6. Hold down the Step and Output keys while starting generator. 7. Choose RD (press Step key) to copy the configuration data from the card to the generator. All user-created objects on the target generator will be deleted. To cancel the operation, press the ACS key. 8. Hold down the ASC, DCS, and DSS keys while starting the generator to return the generator to normal operating mode. 802BT/802R Video Test Generator User Guide 49 Installing firmware Firmware upgrades are available at http://www.quantumdata.com/support/downloads/. Important: Always backup any custom objects (formats, images) stored on the generator before installing an upgrade. The firmware installation re-initializes the generator, which deletes any custom objects. After installing the firmware, you can restore custom objects. Firmware upgrades require the use of VGM. Please refer to the VGM online help for procedures on upgrading the generator. 50 Chapter 3 Administrative Tasks Memory management The generator includes commands to manage its internal memory resources. These commands or useful if the generator exhibits degraded performance or other anomolies. To verify and correct memory related anomolies: 1. Check the generator’s memory for corruption by running a memory self test: MEMT MEMT? 1 // runs the memory self test // returns the results of the memory self test // returned value from the memory self test A value of “0” indicates no memory corruption or inconsistency was found. A value of “1” indicates that there is a memory anomoly. 2. If the memory self test reveals a memory corruption, re-initialize the generator: BOIT // re-initializes the generator 3. If the memory self test does not reveal a memory corruption, check to see if there is enough free memory and contiguous memory: MEMF? 808320 MEML? 816568 // // // // queries returns queries returns for the for the the free memory amount of free memory the largest contiguous block of free memory largest contiguous block of free memory If the amount of memory is low or the amount of contiguous memory is low the memory should be compacted. 4. Compact the generators memory: MEMC MEML? 818280 // compacts the memory // queries for the largest contiguous block of free memory // should show larger block of contiguous free memory 802BT/802R Video Test Generator User Guide 51 52 Chapter 3 Administrative Tasks 4 Working with Formats Topics in this chapter: • Overview • Format library • Format naming conventions • Creating custom formats • Editing Format knob lists • Configuring DCS priority scheme • Creating format aliases 802BT/802R Video Test Generator User Guide 53 Overview The generators enable you to create your own formats and edit the Format knob list through the Video Generator Manager (VGM) application and the command line interface. Please refer to the VGM online help for details on procedures for these functions performed through VGM. This chapter provides procedures for customizing formats through the command line interface. The following functions are provided: 54 • Creating formats. If the application environment requires constant switching between video outputs, for example, you can build your own library of customized formats that individually select which video output is driven via the proper setting of AVST and DVST parameters. • Editing the Format knob list. You can edit the Format knob list to include any combination of built-in and user-defined formats. The default operating mode of the 802 uses the Format knob to select formats from a list of built in formats. • Creating aliases. You can assign your own names to formats using aliases. Chapter 4 Working with Formats Format library The generator has a built-in library of formats. The same format library is used for all 802 models. The formats are stored in read-only memory (ROM) along with the generator’s operating code. Compatibility Some formats are for displays and graphics systems that may not be compatible with a specific generator model. Attempting to load an incompatible format will give you an error message. If a format has too high of a pixel rate, a modified version of the format can be created with reduced horizontal timing parameters that bring the pixel clock rate below the limit of the generator. The horizontal and vertical rates however are correct. This lets you light-up a display and verify most of its operation. These modified formats can be created through the FMTJ command which references a global parameter (JRAT) that determines the bandwidth of the generator. 802BT/802R Video Test Generator User Guide 55 Format naming conventions The names used in the built-in format library have been updated for the generator. Many format names on previous versions of the 802 generators have been renamed to more closely match the naming conventions used in the display industry or in the appropriate standards. There are three sets of naming conventions described in this section: 1) Composite television formats, 2) Component television formats, and 3) Computer display formats. In addition, several miscellaneous naming conventions are also described. Composite television format names Composite television formats apply to RF, D2, CVBS, and S-VIDEO signal interfaces. Composite television format names consist of a three to five character color coding scheme indicator followed by optional characters that indicate format adjustments. Example Color coding schemes • NTSC • PAL • SECAM Adjustments to the format 56 • 4x == sampling rate is four times the color sub-carrier frequency • 44 == NTSC with color sub-carrier frequency of 4.43361875 MHz (as opposed to 3.58) • # == sampling rate is reduced in order to make pixels square • jp == NTSC-Japan (NTSC without 7.5 IRE setup) • -M == PAL with 3.57561149 MHz color sub-carrier and M timing (M/PAL Brazil) • -N == PAL with 3.58205625 MHz color sub-carrier (N/PAL Argentina, Paraguay, Uruguay) • -N == NTSC color encoding with N timing (NTSC-N) • -60 == PAL format that allows NTSC tape playback on PAL TV (PAL-60) • plusKKKK == Enhanced wide-screen PALplus TV transmission system • p == progressive video game signal (for example, NTSCp or PALp) Chapter 4 Working with Formats Common composite TV formats with sub-carriers and their respective standards: • NTSC - ITU-R BT.470-6 • NTSC# - SMPTE 170M • NTSC#KA - SMPTE 170M • PAL - ITU-R BT.470-6 • PAL# - ITU-R BT.470-6 • PAL#KA - ITU-R BT.470-6 • SECAM Component television format names Component television formats are named by their vertical resolution and scanning method. These formats apply to RGB, YPbPr, YcbCr and HD-SDI video. In component television format naming, the first three or four characters indicate the active vertical lines in the format, the next characters indicate the frame tracing method, and the last two optional characters indicate the frame rate. Example: 480 i 2x 29 Active vertical lines Frame Double tracing clocking method Frame rate Active vertical lines • 480 (active lines with 525 total lines) • 1035 (active lines with 1125 total lines) Frame tracing methods • p = progressive • i = interlaced • s = segmented frame interlace (e.g. 1080s24, where a 24p frame is segmented into two interlaced fields occurring at twice the frame rate - scene changes only between field pairs – also known as “48sF”) • x = any – progressive, interlace, or segmented 802BT/802R Video Test Generator User Guide 57 Double clocking • i2x = double-clocked interlace (scene may change between fields) pixels are double-clocked for DVI compatibility) Frame rate Frame rate is optional. If no frame rate is given, then the frame rates are assumed. • 24 = 24 Hz • 60 = 60 Hz Common component TV formats • 480pLH Component SDTV signal containing letterboxed 16x9 high-definition content • 480pSH Component SDTV signal containing anamorphically under-sampled 16x9 content Computer display format names Computer display formats are assumed to use progressive scanning. In computer format naming, the first three characters indicate the vendor ID using the EISA ID (for example, IBM, SUN, VSC) or the display type, the next two characters indicate the approximate horizontal resolution, the next two digits indicate the frame rate (which will be half the field rate with interlace scanning), and the final character designates the aperture (used only when the aperture is not A). Example Vendor ID (EISA) • SMT for VESA (digital) Safe Mode Timing • DMT for VESA Standard Discrete Monitor Timing • GTF for VESA Generalized Timing Format standard • CEA for Consumer Electronics Association • EIA for Electronics Industries Association (CEA) Approximate horizontal resolution examples 58 • 02 for 256 pixels • 09 for 960 pixels Chapter 4 Working with Formats • 12 for 1200 pixels • 30 for 3072 pixels Frame rate examples (half the field rate with interlace scanning) • 48 for 48Hz • 60 for 60Hz • 75 for 75Hz Aperture (used only when the aperture is not A) See “Aperture designators” on page 59. Common computer display formats • VSC1275 for Viewsonic 1280 by 1024 at 75 Hz • DMT0685 for Discrete Monitor Timing with 680 by 480 at 85 Hz Aperture designators Format names may include one or two characters that describe the aperture of the display. These are listed below. Aspect ratio • Q = 1.00:1 Quadrate - MIL, Radiology (square, 512x512, 1024x1024) • G = 1.25:1 Graphics workstation (5x4, 1280x1024, 1600x1280) • A = 1.33:1 Academy (4x3, 640x480, 800x600, 1024x768, 1280x960, 1600x1200) • B = 1.44:1 Big (13x9, IMAX™) • T = 1.50:1 Three halves (3x2, 1152x768 Apple Computer) • V = 1.56:1 PALplus WWS case #2 (14x9, see ITU-R BT.1119) • D = 1.60:1 VESA CVT proposed (16x10, 1728x1080, 1280x800) • E = 1.67:1 European film (15x9 or 5x3, 1200x720, 1280x768, 1800x1080, a.k.a. “1.66”) • H = 1.78:1 High-definition image (16x9, 1280x720,1920x1080) • F = 1.85:1 US film (320x173, 1280x692, 1920x1038) • U = 2.00:1 Univisum™ (2x1, 1280x640, 1920x960) • C = 2.39:1 CinemaScope™ (160x67, 1280x536, 1920x804, a.k.a. “2.35”, was 2.35 before 1971) Content fitting operators • N = Natural (do nothing) 802BT/802R Video Test Generator User Guide 59 • L = Letterbox (linear scale to fit one axis, center w/black bars in other) • Z = Zoom (blow- up to fill destination aperture with cropping, or LI ) • S = Scope (under-sample content horizontally) • W = Widescreen (over-sample content horizontally) • J = Justify (non- linear horizontal expand – more near edges) • K = Keep safe (shrink to avoid cropping – provide safe title) • P = Pan & Scan (truncate) • M = Mirror (horizontally – rear projection) Other Modifiers • I = Inverse (undo operator; for example, S = Scope and SI = Inverse Scope) • O = Orthogonally (rotate operator effect or aperture 90 degrees) • X = Wildcard or special Using legacy format names You can configure the generator to display names using conventions from older generator models. Important: Configuring the generator to use legacy names will delete all user-defined video formats currently stored in the generator. Therefore, it is important to back up the user data files from the generator to disk and then restore them back to the generator. VGM can be used to backup the generator. To display legacy format names: 1. Turn the generator off. 2. Hold down the G key, and then power on the generator. The following message appears on the front panel LCD. 3. Release the G key. This setting is retained throughout subsequent power cycles. To re-assert the default format names you must reinitialize the generator: 1. Turn the generator off. 2. Hold down the ACS and DSS keys and then power on the generator. 60 Chapter 4 Working with Formats Viewing the format library You can view the list of formats available in the generator using VGM or the command line interface. Please refer to the VGM online help for instructions on using VGM to view the format list. To display the format list: 1. Establish a terminal session with the generator. 2. Load the default format directory (fmt) or custom format directory by entering the following command: DIRL fmt 3. List the contents of the format directory by entering the following command: NAMQ? 1 200 // lists the formats from the first format through 200 Viewing format details You can view the format parameters of any standard or custom format using VGM or the command line interface. Please refer to the VGM online help for instructions on using VGM to view format details. Use the following procedure to view the detailed format information through the command line interface. To view formats parameters using the Format image: 1. Connect the generator with a display. 802BT/802R Video Test Generator User Guide 61 2. Load the Format image. Information about the current format is displays. 3. Press the Step key, then turn Image knob to view additional formats. To display individual format parameters: 1. Establish a terminal session with the generator. 2. Load the format whose parameters you want to view by entering the following command: FMTL format; FMTU //specify a valid format name 3. Enter the format parameter(s) you want to view. For example, to view the horizontal resolution, vertical resolution, horizontal period, and analog video sync type, enter the following command: HRES? VRES? HTOT? AVST? The generator responds with the information in sequence as shown below: 640;480;800;2 62 Chapter 4 Working with Formats Creating custom formats You can create new signal formats for the generator and add them to non-volatile memory. You can create formats through VGM or by using a command line interface (either the RS-232 port or the IEEE-488 port). The recommended procedure for creating new formats is to use VGM. VGM contains the algorithms for ensuring compatibility between format parameters where there are dependencies in their respective values. Please refer to the VGM online help for information about creating formats using VGM. Determining the signal specifications of the display Your custom format will be based on the specifications of the display under test. Typically, you can find the information required for the format in the detailed specification sheet for the display. At a basic level, you must determine if you are working with an analog or a digital display. An analog display can show an endless range of colors or shades of gray. Analog displays normally accept video signal levels in the 1 Vp-p range. Digital displays are more limited and can display only a few gray levels or a limited number of pre-defined colors. These displays normally accept TTL video signals in the 4 Vp-p range. Creating custom formats using the command line interface There are two methods for creating formats through the command line interface. The first method is to use the FMTN command to set all format parameters in the format buffer to their default values, and then modify each value. The second method is to select an existing format to use as a template for the new format, and then modify only the values needed to create the new format. When using this method, you can save the new format under a new name or the existing name. Independent of the method you choose, you can enter each command interactively or, using your computer, create a text file containing all the commands you want to issue, and then download the text file to the generator. For instructions on creating and downloading text files, see “Sending commands from text files” on page 16. Creating a new format The FMTN command is used in creating a new format. This command sets all of the format parameters to known, default values. For a list of the parameters and their default values, see “FMTN” on page 331. Use the following procedure to create a new format using interactive commands. 802BT/802R Video Test Generator User Guide 63 To create a new format: 1. Establish a terminal session with the generator. See “Setting up a terminal connection with the generator” on page 14. 2. Enter the following commands to initialize all parameters to default values and begin a format editing session: FMTN FMTB // initializes all parameters to default values // begins a format editing session 3. Enter the format parameter commands in sequence to set the values for the new format. HRES 654 . . . HTOT 720 // sets the horizontal resolution to 654 pixels // other format parameters // sets the horizontal total to 720 pixels Note: You do not need to enter a parameter value if it matches the FMTN default setting. 4. End the editing session and save the new format using the following commands: FMTE FMTA new_fmt_name // ends a format editing session // saves format as new specified name 5. Assign the format to the knob list using the following commands: DIRL FMT DIRB NAMI 20 new_fmt_name DIRE DIRS // // // // // loads format directory into edit buffer begins a directory edit session assigns format to format knob list at 20 ends a directory editing session saves contents of directory as current name Creating a format based on an existing format Use the following procedure to create a format based on an existing format using interactive commands. To create a custom format based on an existing format: 1. Determine the signal specifications of the display under test and select an existing format in the generator’s format library whose parameter values are similar. 2. Connect the display to the generator. 3. Using the Format knob, select the format you want to use as a template for the new format. 4. Using the Image knob, select the Format image to view the parameters of the selected format. 5. Establish a terminal session with the generator. 64 Chapter 4 Working with Formats 6. Enter the following commands to load and begin editing the existing format. FMTL format_name FMTB // loads existing format into the format editor // begins a format editing session 7. Enter the format parameter commands in sequence where the new values differ from the existing format values. For example to modify the horizontal resolution enter the following command: HRES 654 Note: You do not need to enter parameter values if they match the existing format. 8. End the editing session and save the new format using the following commands: FMTE FMTA new_fmt_name // ends a format editing session // saves format as new specified name 9. Assign the format to the knob list using the following commands: DIRL FMT DIRB NAMI 20 new_fmt_name DIRE DIRS // // // // // loads format directory into edit buffer begins a directory edit session assigns format to format knob list at 20 ends a directory editing session saves contents of directory as current name Modifying existing formats The following procedure demonstrates how to modify the parameters of an existing format using the command interface. This example changes an existing digital format from RGB 4:4:4 to YCbCr 4:2:2, and saves the format into the default format directory. To edit an existing format: 1. Establish a terminal session with the generator. 2. Set the generator to digital friendly mode: SROP 2 (or SROP 2 4) SROP 8 // sets generator to digital friendly mode // sets generator to status display mode 3. Load and begin editing the format: FMTL existing_format FMTB // loads existing format into format editor // begins a format editing session 4. Enter the format parameter commands in sequence where the values differ from the default values. For example to modify the component video type enter the following command: DVST 14 DVSM 2 ALLU // changes the component color to YCbCr // changes component color make up to 4:2:2 // loads hardware and outputs new signal 5. End the editing session and save the format using the following commands: FMTE 802BT/802R Video Test Generator User Guide // ends the format editing session 65 FMTA new_fmt_name // saves format as new specified name 6. Assign the format to the knob list using these commands: DIRL FMT DIRB NAMI 20 new_fmt_name DIRE DIRS // // // // // loads format directory into edit buffer begins a directory edit session assigns new format to format knob list at 20 ends a directory editing session saves contents of directory as current name 7. Load the new format using these commands: FMTL new_fmt_name FMTU 66 Chapter 4 Working with Formats // loads new format in edit buffer // applies new format to the generator Editing Format knob lists Stepping through all of the available formats using the Format knob can be time consuming. This is particularly true if you regularly use only a few formats that may be scattered throughout the list. You can set up the 802 to show only the formats you want, in the order you want, when you turn the Format knob. The 802 maintains a list of these formats in non-volatile memory, and you can edit the list to include formats you have created and to remove any unneeded formats. You can edit the Format knob list using the internal editor or the command line interface; however, the most convenient way to edit the list and create custom knob lists is through VGM. Please refer to the VGM online help for instructions on creating and editing format knob lists. The default Format knob list is named fmt. In addition to editing this list, you can also create new lists and name them to reflect their uses at your site. Editing format knob list using internal editor Use the following procedures to edit the format knob list using the internal format editor. To edit the format knob list: 1. Power-up the generator while holding down the Image key until programmer is displayed. 2. Select the FmtList image. 802BT/802R Video Test Generator User Guide 67 3. Press the Step key to start the Format List editor. The left side of the screen shows the current contents of the format list. The formats appear in the order that they are selected by the Format knob during normal operation. The right side of the screen shows the available formats. 4. Use the Format and Image knobs to select formats in the lists. Use these commands to edit the format list. Key Function Insert (DCS) Inserts the format selected from the list of available files at the cursor position in the format list. Delete (B) Remove the selected format from the format list. Move (R) Moves the selected format in the format list to another position in the list. To move the selected format, press Move, use the Format knob to specify the target position, and then press the Move key again. Remove (DSS) Deletes the format selected in the list of available formats. This will erase the entire contents of the file from non-volatile memory. Since this operation can destroy a lot of programming work, an on-screen message will ask you to confirm the removal of the file. Pressing the Yes or OK key will erase the file. Pressing the No or Cancel key will abort the removal operation. 5. Press the Exit (Step) key to save the edited list and exit the editor. 68 Chapter 4 Working with Formats Editing format knob list using command line interface Use the following procedures to edit the format knob list and create new knob lists through the command line interface. To insert a format at a specific location in a format knob list: 1. Establish a terminal session with the generator. 2. Create a format and save it to the generator (see “Creating custom formats” on page 63.) 3. Enter the following commands: DIRL fmt DIRB NAMI 257 MyFormat DIRE DIRS // // // // // loads default format list (fmt) begins a directory editing session inserts format named MyFormat at position 257 ends the directory editing session saves contents of directory as current name To remove a format from a specific location in the format knob list: DIRL fmt DIRB NAMK MyFormat DIRE DIRS // // // // // loads default format list (fmt) begins a directory editing session deletes format named MyFormat ends the directory editing session saves contents of directory as current name To create a new format knob list, enter the following commands: DIRL DIRB NAMK . . . NAMK NAMI . . . NAMI DIRE DIRA fmt format_1 // loads default format list (fmt) // begins a directory editing session // deletes format_1 // deletes other formats format_x 1 new_format_1 // deletes format_x // inserts new_format_1 at location 1 // insert other formats x new_format_x new_fmt // inserts new_format_x at location x // ends the directory editing session // saves new format list as new_fmt To apply a new format knob list: FMTP new_fmt 802BT/802R Video Test Generator User Guide // loads format list new_fmt 69 Configuring DCS priority scheme There are two priority schemes for putting composite sync (CS) on the separate VS and HS sync outputs when digital composite sync (DCS) is selected through types SSST = 2, 6, or 11. This applies to both the VS and HS pins of the VGA connector and to the analog component BNC connectors. • Legacy DSC priority scheme • Default DSC priority scheme The following table describes the legacy DCS priority scheme for horizontal sync. OUTG SSST HSPG VSPG HS Output HS Polarity 0 Do not care Do not care Do not care No signal Do not care 1 Do not care 0 Do not care No signal Do not care Do not care 8 (DPMS – OFF) Do not care Do not care No signal Do not care 1 9 (DPMS – SUSPEND) Do not care Do not care Horizontal Sync HSPP 1 10 (DPMS – STANDBY) Do not care Do not care No signal Do not care 1 1, 3, 5, 7, or 11 1 Do not care Horizontal Sync HSPP 1 2, 6, or 11 (DCS) Do not care Composite Sync HSPP 1 The following table describes the legacy DCS priority scheme for vertical sync. 70 OUTG SSST HSPG VSPG VS Output VS Polarity 0 Do not care Do not care Do not care No signal Do not care 1 Do not care Do not care 0 No signal Do not care Do not care 8 (DPMS – OFF) Do not care Do not care No signal Do not care 1 9 (DPMS – SUSPEND) Do not care Do not care No signal Do not care 1 10 (DPMS – STANDBY) Do not care Do not care Vertical Sync VSPP 1 1, 3, 5, 7, or 11 Do not care 1 Vertical Sync VSPP 1 2, 6, or 11 (DCS) 1 Do not care No signal Do not care 1 2, 6, or 11 (DCS) 0 1 Composite Sync VSPP Chapter 4 Working with Formats The following table describe the default DCS priority scheme for horizontal sync. OUTG SSST HSPG HS Output HS Polarity 0 Do not care Do not care No signal Do not care 1 Do not care 0 No signal Do not care Do not care 8 (DPMS – OFF) Do not care No signal Do not care 1 9 (DPMS – SUSPEND) Do not care Horizontal Sync HSPP 1 10 (DPMS – STANDBY) Do not care No signal Do not care 1 1, 3, 5, 7, or 11 1 Horizontal Sync HSPP 1 2, 6, or 11 (DCS) 1 Composite Sync CSPP The following table describe the default DCS priority scheme for vertical sync. OUTG SSST VSPG VS Output VS Polarity 0 Do not care Do not care No signal Do not care 1 Do not care 0 No signal Do not care Do not care 8 (DPMS – OFF) Do not care No signal Do not care 1 9 (DPMS – SUSPEND) Do not care No signal Do not care 1 10 (DPMS – STANDBY) Do not care vertical Sync VSPP 1 1, 3, 5, 7, or 11 1 vertical Sync VSPP 1 2, 6, or 11 (DCS) 1 Composite Sync CSPP To enable the legacy DCS priority scheme: 1. Turn off the generator. 2. Hold down the Step and DCS keys while starting the generator. The generator will remain in this mode through subsequent power cycles until the generator is re-initialized or reset with the “No special modes” command (hold down ACS+DCS+DSS while starting the generator). 802BT/802R Video Test Generator User Guide 71 Creating format aliases You can create aliases for formats to suit the needs of your site. Use the following procedure to create an alias for a format, save it to the format directory, and then use the alias. To create and use a format alias: 1. Establish a terminal session with the generator. 2. Enter the following commands: ALIN DIRL DIRB NAMI DIRE DIRA your_alias format FMT 1 “your_alias” FMT // // // // // // assigns alias to format loads default format list (fmt) begins a format editing session assigns alias to format directory ends a format editing session saves alias in default format directory To delete a format alias, enter the following command: ALIK your_alias 72 Chapter 4 Working with Formats // removes the alias 5 Working with Images Topics in this chapter: • Overview • Creating custom images • Downloading bitmap images from a PCMCIA card • Looping through images • Editing Image knob list • Creating image aliases 802BT/802R Video Test Generator User Guide 73 Overview The 802R/BT includes a library of 250 test images. In addition, you can create custom images, which consist of one or more drawing primitives, including single pixel dots, lines, rectangles, and ovals. You can select the grayscale and color tables used in the image and save the images in non-volatile memory. Custom images can be added to the list of built-in images that can be selected with the Image knob. You can create and edit test images and edit the Image knob list using the Video Generator Manager (VGM) application or the command line interface. Please refer to the VGM online help for details on creating custom images using VGM. The following functions are provided: • Creating images. You can create your own custom images and add them to the image library. • Downloading bitmap images. You can also create your own images in other applications and save them as bitmap files which can then be downloaded using a terminal emulator or from a PCMCIA card. • Editing the Image knob list. You can edit the Image knob list to include any combination of built-in and custom images. The default operating mode of the 802 uses the Image knob to select images from an internal list of built-in images. • Setting up a looping image display. You can set up a continuous cycling mode that draws images one-after-another in an infinite loop. Image looping can be used for burn-in testing or for running single-mode displays at trade shows. • Creating aliases. You can assign your own names to images using aliases. Viewing the image list You can view the list of images available in the generator using VGM or the command line interface. Please refer to the VGM online help for details on viewing the image list using VGM. Use the following procedure to view the image list using the command line interface. To display the image list: 1. Establish a terminal session with the generator. See “Setting up a terminal connection with the generator” on page 14. 2. Load the default image directory (img) or custom image directory by entering the following command: DIRL IMG 3. List the contents of the image directory by entering the following command: NAMQ? 1 200 74 Chapter 5 Working with Images // lists the images from the first through 200 Creating custom images This section describes how to create images and add them to the generator’s image library, and how to customize the image list. The recommended method for creating images is create a text file containing the commands for creating the image, and then downloading the text file to the generator. Another method for creating images is to use the Image Editor in VGM to create a basic image, save the basic image as a command file in VGM, and then open and edit the command file to refine the image as needed. To create custom images with a command file: 1. Using a text editor, open a text file (command file) on your computer and enter the following commands. OUTG IMGN IMGB XRES YRES . . . IMGE IMGA OUTG IMGU ALLU 0 new_image // gates all video and sync outputs off // creates a new image // begin an image editing session // sets the horizontal resolution // sets the vertical resolution 640 480 // other image parameters // ends an image editing session // saves image as new_image // gates all video and sync outputs on // draws the image // applies the buffer to the generator hardware new_image 1 2. Save the text file, using a *.txt extension. 3. Establish a terminal session with the generator. See “Setting up a terminal connection with the generator” on page 14. 4. At the R:> prompt, transfer the text file to the generator. For example, to transfer a file using HyperTerminal, do the following: a. On the Transfer menu, click Send Text File. The Send Text File dialog box appears. b. Select the text file you want to send, and then click Open. HyperTerminal displays the commands as they are sent. c. Press Enter once to ensure that the last command is sent. 5. Assign the image to Image knob list by entering the following commands: DIRL IMG DIRB NAMI 20 new_image DIRE DIRS 802BT/802R Video Test Generator User Guide // // // // // loads image directory into edit buffer begins a directory editing session assigns image to image knob list at 20 ends a directory editing session saves contents of directory as current name 75 Command file example The following sample command file creates the image shown in the graphic below. Commands used to draw image above: IMGN IMGB XRES YRES HATO OVAL CROS RECT RECT RECT RECT RECT RECT RECT RECT RECT RECT RECT FORM RECT RECT RECT RECT RECT RECT RECT 76 // begin an editing session 640 // set the horizontal resolution 480 // set the vertical resolution Foreground 24 18 Foreground 479 479 80 0 GrayPat0 White White 205 154 770 77 GrayPat50 Black 128 96 30 45 GrayPat100 Black 128 96 482 45 GrayPat100 Black 128 96 30 345 GrayPat100 Black 128 96 482 345 GrayPat100 Red 30 96 184 347 GrayPat100 Blue 30 96 243 347 GrayPat100 Yellow 30 96 273 347 GrayPat100 Cyan 30 96 303 347 GrayPat100 Magenta 30 96 333 347 GrayPat100 Blue 30 96 363 347 GrayPat100 White 271 78 Green 30 96 213 347 GrayPat100 Green 30 96 393 347 GrayPat100 Red 30 96 423 347 GrayPat100 White 128 96 30 45 GrayPat7 White 128 96 482 45 GrayPat7 White 128 96 30 345 GrayPat7 White 128 96 482 345 GrayPat7 Chapter 5 Working with Images IMGE IMGA MyImage 802BT/802R Video Test Generator User Guide // end an editing session // save image as MyImage 77 Downloading bitmap images from a PCMCIA card This section describes how to store a bitmap image on a standard PCMCIA memory card, and then load the image as you would a built-in image. The generator can load only one image from a card. Although you can download an image using VGM, loading an image from a card is faster and easier. This feature is supported on 802BT and 802R generators with video board FPGA 91 or later, DVI daughter card FPGA 0xE3 or later, and firmware 7.3834000 or later (802BT) or 7.38180000 or later (802R). To determine your generator specifications, “Displaying system information” on page 44. To copy an image onto a card: 1. Save the image you want to store on the card as an 8-bit or 32-bit (24-bit TrueColor) bitmap (.bmp) file on your computer using any file name. 2. Hold down the ACS, DCS, and DSS keys, and then cycle the power to the generator. This removes any special modes and sets the baud rate of the serial port to 2400 bps. 3. Establish a terminal session with the generator and change the baud rate of the generator to 38400 bps (see “Changing the baud rate” on page 15.) 4. Insert a PCMCIA card into the slot in the generator. 5. At the R:> prompt, enter the following command to initiate the YMODEM-BATCH file-upload protocol: YMDI 6. At the R:> prompt, transfer the file to the card. For example, to transfer a file using HyperTerminal, do the following: a. On the Transfer menu, click Send File. The Send File dialog box appears. b. In the Filename box, click Browse and select the bitmap file you want to copy to the generator. c. In the Protocol box, click the down arrow and select Ymodem. d. Click Send. Note: You must send the image within about 15 seconds after sending the YMDI command. If the R:> command prompt appears before you send the image, send the YDMI command again, and then send the image again. For descriptions of any error codes displayed, see Appendix C, “Error Messages.” To view an image stored on a PCMCIA card: 1. Insert the card that contains the image you want to view. 78 Chapter 5 Working with Images Note: The card you need is a Type 1, Battery Backed RAM PCMCIA card with at least 2 MB of storage. These cards are available from synchrotech P/N PCM-SRW-AM002 2MB. Flash or compact type memory cards will not work. 2. Use one of the following procedures to configure the generator to use a format with the same pixel depth as the image: • Select a built-in format with the appropriate pixel depth. • Create a format with the appropriate pixel depth. • Establish a terminal session with the generator and enter the following commands to set the pixel depth to 32-bit (24-bit TrueColor) or 8-bit: PELD 32; ALLU or PELD 8; ALLU • Hold down the R key while pressing and releasing the G key to toggle the pixel depth between 8 and 32-bit pixel depths. 3. Using the Image knob, select the CardBMP image, or enter this command: IMGL CardBMP; ALLU The image appears on the display. 4. To view an image from a different card, switch the cards, and then re-select the CardBMP image. 802BT/802R Video Test Generator User Guide 79 Looping through images You can set up a continuous cycling mode that draws all images in the image knob listone-after-another in an infinite loop. When activated, the message “Loop Enabled” appears on the display under test. To enable image looping: 1. Using the Format knob, select a format compatible with the display under test. 2. Turn the Image knob clockwise beyond the last image in the Image list about one turn. The message “Loop Enabled” appears on the display under test. After a second or two, the first image in the cycle appears and the generator continuously cycles through the test image list using a given format in this mode. To disable image looping: 1. Turn the Image knob counter-clockwise to stop image looping. 80 Chapter 5 Working with Images Editing Image knob list If your test environment requires only a subset of the available built-in images, you can configure the 802 to show only the images you want, in the order you want, when the Image knob is turned. The 802 maintains a list of these images in non-volatile memory. You can edit this list to include images you have created and to remove unneeded images. The Image knob list can be edited using the command line interface; however, the most convenient way to edit the knob list and create custom knob lists is using VGM. Please refer to the VGM online help for procedures on editing image knob lists. The default Image knob list is named img. In addition to editing this list, you can also create new lists and name them to reflect their uses at your site. Editing image knob list using internal editor Use the following procedures to edit the image knob list using the internal image editor. To edit list of images: 1. Power-up the generator while holding down the Image key until programmer is displayed. 2. Select the ImgList image. 3. Press the Step key to start the image list editor. The left side of the screen shows the current contents of the image list. The images are listed in the order that they are selected by the Image knob during normal operation. The right side of the screen shows all of the available images. The built-in images are at the top of the list, followed by a factory default custom image. This image is used as starting point to creating you own custom images. Any user-defined images in non-volatile memory are at the bottom of the list. 4. Use the Format and Image knobs to select images in the lists. Use these commands to edit the image list. Key Function Insert (DCS) Inserts the image selected in the list of available files before the image selected in the image list. The current firmware does not allow entering a secondary version of a built-in image to the list. The primary version will need to be first selected during normal operation. Pressing the Image key will then select the secondary version. Delete (B) 802BT/802R Video Test Generator User Guide Remove the selected image from the image list. 81 Key Function Move (R) Moves the image selected in the image list to another position in the list. To move the selected image, press Move, use the Format knob to specify the new position, and then press the Move key again. Remove (DSS) Deletes the selected user-defined image from the list of available files. This will erase the entire contents of the file from non-volatile memory. Standard images cannot be deleted. 5. Press the Exit (Step) key to save the list and exit the editor. Editing Image knob list using command line interface Use the following procedures to edit the Image knob list and create new knob lists through the command line interface. To insert an image at a specific location in the default image knob list: 1. Establish a terminal session with the generator. 2. Create a custom image and save it to the generator. See “Creating custom images” on page 75. 3. Enter the following commands: DIRL img DIRB NAMI 111 MyImage DIRE DIRS // // // // // loads default image list called img begins a directory editing session inserts image named MyImage at position 111 ends the directory editing session saves the contents of directory as current name To remove an image from a specific location in the image knob list: DIRL img DIRB NAMK MyImage DIRE DIRS // // // // // loads default image list called img begins a directory editing session deletes image named MyImage ends the directory editing session saves the contents of directory as current name To create a new image knob list: DIRL DIRB NAMK . . . NAMK NAMI . . . NAMI 82 img image_1 // loads default image list called img // begins a directory editing session // deletes image named image_1 // deletes other images image_x 1 new_image_1 // deletes image_x // inserts new_image_1 at location 1 // inserts other images x new_image_x Chapter 5 Working with Images // inserts new_image_x at location x DIRE DIRA new_img // ends the directory editing session // saves new image list as new_img To apply a new image knob list: IMGP new_img 802BT/802R Video Test Generator User Guide // loads image list new_img 83 Creating image aliases You can create image aliases to suit the needs of your site. Use the following procedure to create an alias for an image, save it to the image directory, and then use the image. To create and use an image alias: 1. Establish a terminal session with the generator. 2. Enter the following commands: ALIN DIRL DIRB NAMI DIRE DIRA your_alias image IMG 1 “your_alias” IMG // // // // // // assigns alias to image loads default image list (img) begins an image editing session assigns alias to image directory ends an image editing session saves alias in default image directory To delete an image alias: Enter the following command: ALIK your_alias 84 Chapter 5 Working with Images // removes the alias 6 Working with Test Sequences Topics in this chapter: • Overview • Creating a test sequence • Viewing the test sequence list • Running a sequence 802BT/802R Video Test Generator User Guide 85 Overview When testing video displays, you typically select a format using the Format knob, and then select an image using the Image knob. In a production environment, where there might be a need to test several combinations of formats and images, you can create a test sequence to automate the process of selecting formats and images. Test sequences provide a way to progress through a pre-defined sequence of format and images, either manually or automatically. You can create test sequences using the command line interface, the internal sequence editor or the Video Generator Manager (VGM) application. This section describes how to create and run test sequences using the command line interface and internal sequence editor. Please refer to the VGM online help for instructions on defining and running a test sequence from VGM. The following functions are provided: 86 • Create your own custom test sequences consisting of multiple steps. Each step specifies the format and image to display as well as the duration of the step. You can create multiple sequence files, which are stored in non-volatile memory. • Program the 802R/BT generator to run in test-sequence mode on power-up. This mode of operation is useful in a manufacturing test environment where the same test procedure must be repeated on many identical displays. Multiple test sequences can be stored in the generator and selected by the operator. Chapter 6 Working with Test Sequences Creating a test sequence You can create a test sequence using the command line interface, the generator’s built-in editor or VGM. Creating a test sequence using command line You can develop test sequences either by entering command interactively through a terminal session or by entering a series of commands in a text file and then send them to the generator through hyper terminal. When developing long test sequences, the recommended procedure is to enter commands in a text file, and then send the file to the generator. This approach enables you to change the test sequence without entering the entire command script. Use the following procedure to create a test sequence, save it to the sequence directory, and then run it using the command line interface. To create and save a test sequence interactively using the command line interface: 1. Establish a terminal session with the generator. 2. Enter the following commands to create a three-step sequence named MySeq. SEQN SEQB STEP SDLY FMTL IMGL STEP SDLY FMTL IMGL STEP SDLY FMTL IMGL SEQE SEQA // // 1 // 5.0 // 480p59 // SMPTEbar // 2 // 5.0 // 720p60 // Outline1 // 3 // 5.0 // 1080i29 // Geom_4 // // MySeq // initializes the sequence edit buffer begins a sequence editing session selects a step to be edited sets the delay for the current step to five seconds loads a format loads an image selects a step to be edited sets the delay for the current step to five seconds loads a second format (same image) loads an image selects a step to be edited sets the delay for the current step to five seconds loads a third format loads another image ends the sequence editing session saves the current contents of the sequence editor To create and save a test sequence from a text file: 1. Using a text editor, open a text file (command file) on your computer and enter the following commands to create a three-step sequence named MySeq.: SEQN SEQB STEP 1 SDLY 5.0 FMTL 480p59 802BT/802R Video Test Generator User Guide // // // // // initializes the sequence edit buffer begins a sequence editing session selects a step to be edited sets the delay for the current step to five seconds loads a format 87 IMGL STEP SDLY FMTL IMGL STEP SDLY FMTL IMGL SEQE SEQA SMPTEbar 2 5.0 720p60 Outline1 3 5.0 1080i29 Geom_4 MySeq // // // // // // // // // // // loads an image selects a step to be edited sets the delay for the current step to five seconds loads a second format (same image) loads an image selects a step to be edited sets the delay for the current step to five seconds loads a third format loads another image ends the sequence editing session saves the current contents of the sequence editor 2. Save the text file, using a *.txt extension. 3. Establish a terminal session with the generator. 4. Transfer the text file to the generator. For example, to transfer the file using HyperTerminal, do the following: a. On the Transfer menu, click Send Text File. The Send Text File dialog box appears. b. Select the text file you want to send, and then click Open. HyperTerminal displays the commands as they are sent. c. Press Enter once to ensure that the last command is sent. To insert a sequence at a specific location in the sequence list: 1. Establish a terminal session with the generator. 2. Enter the following commands: DIRL seq DIRB NAMI 1 MySeq DIRE DIRS // // // // // loads sequence directory into edit buffer begins a directory editing session assigns sequence to sequence list at 1 ends the directory editing session saves contents of directory as current name Creating and editing test sequences using the internal editor You can use the generator’s internal Sequence Editor to create, edit and run test sequences without using VGM. The 802 can be configured to allow an operator to run only certain sequence files in the sequence mode. The 802 maintains a list of these accessible sequences in non-volatile memory. You will need to edit the list if you wish to add sequences you have created. The procedures for creating and editing the sequence file list are provided below. To create a test sequence using the internal sequence editor: 1. Turn on the generator while pressing the Image key until programmer is displayed. 2. Select the SeqList image. 88 Chapter 6 Working with Test Sequences 3. Press the Image key to start the Sequence List editor. 4. Use the Image knob to select a sequence file from the list of available files. NewSeq is provided by default to serve as a template. 5. Press the Insert key (DCS) to insert the NewSeq file into the sequence list. 6. Use the Format knob to select the NewSeq file, and then press the Modify key. 7. Use the Format knob to select the field you want to edit. Use the Image knob to select field values. Press Change (Outputs) to apply the selected value. Press Insert (ACS) to insert a new step. Press Clear (G) to delete all steps. Press Delete (B) to delete the selected step. To move the selected step, press Move (R), then use the Format knob to select the target position, and then press Move again. 8. Press Mode (DSS) to specify how the generator should run the sequence file when the generator is started. If you have multiple sequence files, the file with the most recent mode setting you make will apply upon startup. Setting the mode for a file will 802BT/802R Video Test Generator User Guide 89 deactivate the mode status of all other sequence files. If a start-up mode is not set for any sequence file, then the generator will start in the normal operating mode. Mode Display option Description blank If no mode is specified the sequence is not started when the generator is started. step Use the Image knob to advance through sequence steps. You cannot advance past the last step. However, rotating the Image knob forward one revolution past the last step will change the mode to automatic. Rotating the Image knob backward one revolution changes the mode back to manual. Step information is displayed on the LCD only. step -s# Current step number is displayed with image on display being tested. step -display Complete step information (sequence name, format, image, and step number) is displayed with image on display being tested. wrap Use Image knob to advance through sequence steps. Advancing past the last step restarts at the first step. Step information is displayed on the LCD only. wrap -s# Current step number is displayed with image on display being tested. wrap -display Complete step information is displayed with image on display being tested. auto Automatically and continuously cycles though sequence steps, and displays step information on LCD only. auto -s# Current step number is displayed with image on display being tested. auto -display Complete step information is displayed with image on display being tested. 9. Press Save (DCS) to save the sequence file. Use the Format and Image knobs to specify a name for the file by selecting the characters presented. 10. Press Exit (Image) to exit the Sequence Editor, and to return to the Sequence List editor. To edit the list of sequences that can be used: 1. Hold down the Image key while starting the generator, until programmer is displayed. 2. Select the SeqList image. 3. Press the Image key to start the Sequence List editor. The Sequence List box shows a list of sequence files that can be selected with the Format knob. The Available Files box shows all sequence files available. 90 Chapter 6 Working with Test Sequences 4. Use these controls to edit the list of sequence files. Control Description Move Use the Format knob to select the file you want to move, press Move, then use the Format knob to specify the target location, and then press Move again. Delete Removes the selected sequence file from the sequence list. Insert Inserts the sequence file selected from the list of available files into the sequence list. Remove Deletes the sequence file selected in the list of available files from non-volatile memory. Modify Opens the selected sequence file in the Sequence Editor. 5. Press Exit to save the list, and to exit the editor. 802BT/802R Video Test Generator User Guide 91 Viewing the test sequence list You can view the list of test sequences stored in the generator using the command line interface, the internal sequence editor or VGM. Viewing the test sequence list using the command line Use the following procedure to view the test sequence list using the command line interface. To view the sequence list using the command line interface: 1. Establish a terminal session with the generator. 2. Load the default test sequence directory (seq) or custom sequence directory using the following command: DIRL seq 3. List the contents of the sequence directory by entering the following command: NAMQ? 1 4 // lists test sequences from the first through the fourth Deleting a test sequence using the command line Use the following procedure to delete a test sequence list using the command line interface. To delete a test sequence using the command line interface: 1. Establish a terminal session with the generator. 2. Load the default test sequence directory (seq) or custom sequence directory and begin an editing session using the following commands: DIRL seq DIRB 3. Delete the sequence by entering the following command: NAMK myseq ALLU 4. End and save the sequence editing session using the following command: DIRE DIRS 92 Chapter 6 Working with Test Sequences Viewing test sequence using internal sequence editor Use the following procedure to view the test sequence list using the internal sequence editor. To view the sequence list using the internal sequence editor: 1. Hold down the Image key while starting the generator, until programmer is displayed. 2. Select the SeqList image. 3. Press the Image key to start the Sequence List editor. The Sequence List box shows a list of sequence files that can be selected with the Format knob. The Available Files box shows all sequence files available. 802BT/802R Video Test Generator User Guide 93 Running a sequence Regardless of how you created a test sequence you can initiate it through the command line, the built-in editor or VGM. For information on running a test sequence through VGM refer to the VGM help. The instructions for running test sequences through the command line or internal sequence editor are provided below. Running a test sequence using the command line A sequence can run in one of three modes: • Step and stop mode, where the progression of the sequence is under user control, and the sequence halts after the final step. • Step and wrap mode, where the progression of the sequence is under user control, and it continuously loops (repeats the sequence steps). • Automatic mode, which enables automatic progression through the sequence list and also continuous looping. The following procedures describe how to use these modes: To run a sequence in step and stop mode: 1. Establish a terminal session with the generator. 2. Enter the following commands: SEQL MySeq SMOD 1 SEQU // loads MySeq into sequence edit buffer // sets step mode to manual with stop after last step // starts running the sequence 3. Turn the Image knob to progress through the sequence. 4. To stop the sequence, enter the following command: SMOD 0; ALLU To run a sequence in step and wrap mode: 1. Establish a terminal session with the generator. 2. Enter the following commands: SEQL MySeq SMOD 2 SEQU // loads MySeq into sequence edit buffer // sets step mode to manual with wrapping after last step // starts running the sequence 3. Turn the Image knob to progress through the sequence. 4. To stop the sequence, enter the following command: SMOD 0; ALLU 94 Chapter 6 Working with Test Sequences To run a sequence in automatic mode: 1. Establish a terminal session with the generator. 2. Enter the following commands: SEQL MySeq SMOD 3 SEQU // loads MySeq into sequence edit buffer // sets the sequence mode to run in auto mode // starts running the MySeq sequence 3. To stop the sequence, hold down the ACS, DCS, and DSS keys, and then cycle the power to the generator. To run a sequence at power up: 1. Run the sequence in the desired mode. 2. Turn off the power to the generator. 3. Start the generator in normal operating mode (without holding down any keys). 4. Depending on the selected mode, the sequence will start automatically, or you can turn the Image knob to move forward and backward though the sequence. The format and image names for each step and the current step number will appear on the LCD. Additional status information may appear before the step number, depending on the mode. This will be S for step, W for wrap and A for automatic. 5. To stop the sequence, hold down the ACS, DCS, and DSS keys, and then cycle the power to the generator. To run a manual sequence continuously: 1. Rotate the Image knob a full turn clockwise beyond the last step. A message on the LCD will confirm that the continuous cycle is running. 2. To stop the cycle, rotate the Image knob counter-clockwise. The generator will remember if the sequence was in continuous cycle mode on power down. If so, it will remain in continuous cycle mode when the generator is powered on. Running a test sequence using internal sequence editor To run a sequence, that was created using the internal sequence editor: 1. Configure one sequence file with a mode setting through the sequence editor (see “Creating and editing test sequences using the internal editor” on page 88). 2. Start the generator in normal operating mode, without holding any keys down. 802BT/802R Video Test Generator User Guide 95 3. Depending on the mode of the sequence, the sequence will start automatically, or you need to turn the Image knob to move forward and backward though the sequence. The LCD will display the format and image name for each step, and the current step number. Additional status information may appear before the step number, depending on the mode (manual, automatic, wrap). A manual mode sequence can be set to continuously cycle through all the steps, by rotating the bottom knob a full turn clockwise beyond the last step. A message on the LCD will confirm that the continuous cycle is running. The cycle is stopped by rotating the bottom knob counter-clockwise. The generator will remember if the sequence was in continuous cycle on power down. If so, it will continuous cycle on power on. If multiple sequences have been defined, use the Format knob to load other sequences. Note: When controlling the generator from a program, it is possible to make any sequence the “Power-on” sequence without having it appear on the sequence knob directory. In this case, the generator will power-up in the sequence mode with the selected sequence, but loading a different sequence file with the Format knob, will not allow you to get back to the original power-up sequence file. Cancelling the start-up sequence mode If the generator has been configured to run a sequence at start-up, and you want the generator to start in normal operating mode, you need to power the generator up while indicating “no special modes” (press and hold the ACS, DCS and DSS keys). 96 Chapter 6 Working with Test Sequences 7 Using GPIB Interface Topics in this chapter: • Overview • Setting the GPIB port address • Queries and commands • Status queries and control 802BT/802R Video Test Generator User Guide 97 Overview You can operate and program the 802 generator from an external computer or terminal using either the RS-232C serial port or optional IEEE-488 (GPIB) port. The GPIB port enables the 802 to be used as a programmable video signal source for integration into automated test systems that use IEEE-488 or GPIB communications between instruments. 98 Chapter 7 Using GPIB Interface Setting the GPIB port address The default GPIB address is 15. You can specify a different address. To set the address of the GPIB port directly on the generator: 1. Locate the rotary switches on the back of the generator between the RS-232 port and the GPIB port. These are accessible through the ventilation slots. There are two rotary switches: the one on the left configures the value of the tens digit and the one on the right configures the value of the ones digit. 2. Set the rotary switches first the value of the tens switch and then the value of the ones switch to the desired value. 3. Hold down the DCS key, and then cycle the power to the generator. The port is set to the new address. Note: A normal power cycle will not update the memory to the new switch settings. To set the address of the GPIB port using the command line: 1. Establish a terminal session with the generator 2. (Optional) Enter the following command to check the current address: GPIB? 3. Enter the following command: GPIB address When the address is changed with the GPIB command, the change takes place as soon at the command is issued. The new address setting will be maintained until 1) the address is changed with another GPIB command, 2) the unit is re-initialized with an INIT command, or 3) the unit is re-initialized because the power-up self test found corrupted data in battery-backed system memory. In cases 2 and 3, the GPIB address will revert to the address set on the GPIB address switches if the unit has them, or to 15 if the unit does not have GPIB address switches. 802BT/802R Video Test Generator User Guide 99 Queries and commands The GPIB interface is an ASCII command line interface like the RS-232 command line interface. The communications protocol is per IEEE-488.2 specification. Queries and commands consist of four ASCII upper/lower case characters. Commands do not require a response from the generator, while queries cause the 802 to respond with the required data. You can send multiple commands on the same line by separating the commands with a semicolon (;) followed by a terminator. A terminator is defined as the NL character (ASCII 10), or EOI sent with the last byte of the command. The 802 will not parse any commands received until a terminator is received. All commands are executed sequentially; that is, when a command is parsed it is allowed to finish execution before the next command is parsed, as illustrated in the following figure. Separator ( ; ) Message Terminator Program Message Syntax Separator (;) Command/Query Header Separator (white space) Data Message Unit Syntax Commands Commands instruct the 802 to set a parameter to the value given or perform some function not requiring any additional data. Commands which have an asterisk (*) as their first character are common commands as defined by the IEEE-488.2 standard and generally operate the same in all instruments. All commands are listed and described in Appendix A, “Command Reference.” Commands which do not require any additional data from the controller are self-contained and should be followed by either a message separator (;) or message terminator. Any other characters (except whitespace characters) will cause a command error. Commands which require numeric data must be followed by at least one separator character (whitespace), and then the data. Numeric data sent with a command is in decimal format. Numeric data can be represented in one of three methods: integer, floating point, or scaled floating point. 100 Chapter 7 Using GPIB Interface For example, the following number can be represented in three ways: • Integer (42) • Floating point (42.00) • Scaled floating point (4.200E+01) Queries Queries are comprised of a header followed immediately by a question mark (?). If there are any characters between the query header and the question mark character (including whitespace), a command error will result. Queries, return a response message upon completion of execution. A response message is comprised of the requested data terminated with an NL (ASCII 10) character. For example the following text would be returned in response to the HRAT? (horizontal rate query) message: 3.1500E+04 Note that the HRAT? query returns its parameter in exponential form. Possible returned parameter forms are: • Integer (3965) • Exponential (+3.965E+03) • String ("text string") Output queue When a query is executed, the resulting response message is placed in an output queue where it can be read by the controller. The 802 has an output queue that is 255 bytes long. When a message is present in the output buffer, the MAV (message available) bit in the Status Byte register is set. This varies slightly from the 488.2 standard in that the MAV bit will be set only when at least one complete response message is present in the output queue. A complete response message consists of response message text and a message terminator (NL). Buffer deadlock Buffer deadlock occurs when the 802 tries to put a response message in the output queue when the output queue is full and the controller is held off while sending a new message because the input buffer is full. If deadlock occurs, the 802 will clear its output queue, set the query error (QYE) bit in the Event Status register and proceed to parse incoming messages. If any additional queries are requested while in deadlock, those response messages will be discarded. The 802 will clear the buffer deadlock when it finishes parsing the current command/query. The QYE bit will remain set until read with the *ESR? query or cleared with the *CLS command. 802BT/802R Video Test Generator User Guide 101 Sending commands and queries The generator parses command lines one at a time. Command lines must be terminated with a carriage return ( ).The generator immediately echoes each character as it is received and places it in a command line buffer. This buffer currently has room for a total of 256 characters. If more than 256 characters are sent before sending a , then the following response will be given: Buffer overflow R:\> Upon receiving a carriage return, the generator immediately echoes the and follows it with a line feed ( ). The generator then parses the command line and initiates whatever processing is implied. The generator then responds with one of the following four responses depending on the condition: Command invalid R:\> ... R:\> Execution error: R:\> R:\> Where and are the carriage return and line feed characters, respectively. Note: Handshaking routines should only look for > and not R:\>. In the future, the R:\ part of the prompt may change (for example, may be expanded to indicate the current path). Bench-top generators output the following prompt on their serial port after finishing the power-on procedure. R:\> This feature allows ATE systems to know when the generator is ready. Sending multiple commands and queries per line You cans send multiple commands and queries per line by separating each command or query with a semi-colon (;) character. For example: HTOT 900; ALLU The response to multiple queries will be a series of data elements separated by semi-colons (;). For example, with the VGA_m3 format loaded, the following command string will produce the response shown. HRES?; VRES?; VTOT? 640;480;525 Normally, all of the commands on a command line associated with a single command terminator are read as a single command message without regard for execution or completion order. However, by inserting the *WAI command, you can force the generator 102 Chapter 7 Using GPIB Interface to wait for all preceding commands to be completed before the commands that follow *WAI are processed. For example, sending the following command line causes a red rectangle to be drawn and then overwritten by the colorbar image. IMGL COLORBAR; IMGU; IMGE; RECT RED 200 200 0 0 GRAYPAT100 Note that the IMGU command merely requests that the current image be rendered eventually, not necessarily right away nor in a single attempt. By inserting a *WAI command after the IMGU, the generator is instructed to render the colorbar image first, before rendering the red rectangle. This command ensures that the generator draws the red rectangle on top of the colorbar image. IMGL COLORBAR; IMGU; *WAI; IMGE; RECT RED 200 200 0 0 GRAYPAT100 The generator will wait until the colorbar image has been completely rendered before it reads and executes the RECT command. The *WAI command is required by the IEEE-488.2-1992 standard, but also works with GPIB and RS-232 protocols as well. Completion handshake The generator returns a > prompt immediately after an FMTU, IMGU, ALLU, BOOT, INIT, or SCAL command is received, even if these commands have not finished executing. If the system controlling the generator must know when the process started by one of these commands has been completed, then append *OPC? to the command string. For example, the following command causes the generator to wait until all processes have been completed before responding with the number 1 and sending the > prompt. FMTL VGA_M3; IMGL FLAT; ALLU; *OPC? The *OPC? command is required by the IEEE-488.2-1992 standard, but also works with GPIB and RS-232 protocols as well. Input buffer Since some commands may take longer to execute, the 802 has an input buffer. This input buffer is 255 characters long and can be written to by the host controller while the 802 is busy executing or parsing previous messages. If the input buffer becomes full, the 802 will hold off the controller until there is room in the buffer. For this reason, a program message cannot be longer than 255 characters including terminator. 802BT/802R Video Test Generator User Guide 103 Status queries and control To create applications that control the generator using the GPIB port, it is sometimes necessary to query the status of the generator and set or reset the status bits and bytes. There are two sets of status registers: 1) the Event Status Register and Event Status Enable Register and 2) the Status Byte Register and Service Request Enable Register. These are described in the following paragraphs. Status byte The status byte used by the 802 is the same as that defined by the IEEE-488.2 standard and does not use any other bits of the status byte. The status byte is one part of a complete status reporting system shown in the figure on page 105. The status byte is read by using the serial poll feature of your controller. Requesting service The GPIB provides a method for any device to interrupt the controller-in-charge and request servicing of a condition. This service request function is handled with the status byte. When the RQS bit of the status byte is true, the 802 is requesting service from the controller. There are many conditions which may cause the 802 to request service. For more information about these conditions, see the *SRE command description (page 212). The table below lists the status commands and queries. Status commands and queries 104 Definition *ESE Sets the Event Status Enable register to the given mask value. When a bit in the Event Status register goes high and the corresponding bit in the Event Status Enable register is a 1, it is enabled and will cause the ESB bit in the Status Byte register to go high. *ESE? Returns the current value of the Event Status register. After this command is executed, the Event Status register is cleared. This is the only way of clearing any bit in the Event Status register except by the *CLS command. *SRE Sets the Service Request Enable register to the mask value given. When a bit in the Status Byte register goes true and the corresponding bit in the Service Request Enable register is also true, the 802 will request service using the GPIB. *SRE? Returns the current value of the Service Request Enable register. *STB? Returns the current value of the Status Byte register. The value stored in the Status Byte register is not affected by reading it. *CLS Clears the Event Status register, the Status Byte and the output buffer. Chapter 7 Using GPIB Interface 4 Operation Complete 5 Request Control Execution Error 6 Device Dependent Error Command Error 7 Query Error Power On User Request The following figure illustrates IEEE-488 status reporting. 3 2 1 0 Standard Event Status Register Logical OR & & & & & & & & 7 6 5 4 3 2 1 Queue Not-Empty 0 Standard Event Status Enable Register Output Queue RQS Service Request Generation 7 6 ESB MAV 3 2 1 0 Status Byte Register Logical OR MSS & & & & & & & 7 6 5 4 3 2 1 0 Service Request Enable Register Status byte bit Definition MAV Message available. Indicates that at least one complete response is present in the output buffer. ESB Event status bit. Indicates that one of the enabled conditions in the Standard Event Status register is set. MSS Master summary status. Indicates that the 802 has a reason for requesting service. RQS Request service. This bit is read only by executing a serial poll of the 802. 802BT/802R Video Test Generator User Guide 105 Event Status bit Definition OPC Operation complete. Indicates that all operations have been completed. RQC Request control. Indicates that a device is requesting control. The generator will never request control, so this bit will always be 0. QYE Query error. Indicates that a query request was made while the generator was in deadlock. DDE Device dependent error. Indicates that the generator encountered an error executing a command. EXE Execution error. Indicates that there was an error parsing a parameter. CME Command error. Indicates that there was an unrecognizable command. URQ User request. Indicates that a front panel key has been pressed or that the front panel knob has been turned. PON Power on. Indicates that power has been turned off and on. This bit will always be 0 in the generator. Bus commands The IEEE-488.1 standard defines bus commands, which are sent to the 802 with ATN true. The following table lists bus commands supported by the generator. For more detailed descriptions of these commands, see the IEEE-488.1 and 488.2 standards. Command Description DCL Device clear. Clears the input buffer and output queue, and stops parsing any commands. SDC Selected device clear. Same as DCL. GTL Go to local. Enters the local state. See “Remote/local operation” on page 106. LLO Local lockout. Enters the lockout state. See “Remote/local operation” on page 106. SPE Serial poll enable. Enables transmission of the Status Byte. SPD Serial poll disable. Exits the serial poll state. Remote/local operation The 802 has complete remote/local operation as defined by the IEEE-488.1 standard. All four remote/local states (REMS, LOCS, RWLS and LWLS) are supported. In the remote state (REMS), the 802 is under remote control and messages are processed as received. The generator enters the remote with lockout state (RWLS) if the controller issues the local lockout (LLO) message to the 802. The generator enters the local state (LOCS) when the REN line goes false or the controller issues the go to local (GTL) message to the generator, or a front panel control is actuated. 106 Chapter 7 Using GPIB Interface In the remote with lockout state (RWLS), the generator is under complete remote control and front panel controls are disabled. The generator enters the RWLS state when the controller issues the local lockout (LLO) message to the generator. Front panel access is re-enabled when the controller issues the go to local (GTL) message to the generator. In the local state (LOCS), the generator is under local control and all front panel controls are enabled. Any remote messages received are stored for processing when the generator enters the remote state again. The generator enters the remote state (REMS) if the REN line is true and the generator is addressed to listen. In the local with lockout state (LWLS), the generator is under local control, and all front panel controls are enabled. Any remote messages received are stored for processing when the generator enters the remote state again. The generator enters the remote with lockout state (RWLS) if it is addressed to listen. 802BT/802R Video Test Generator User Guide 107 108 Chapter 7 Using GPIB Interface 8 Analyzing Digital Sources and Cables Topics in this chapter: • Getting started • Measuring timing of video signal • Testing cables and distribution systems • Measuring pixel errors • Testing InfoFrames (HDMI only) • Testing audio (HDMI only) • Controlling analyzer using command-line interface • Generating pseudo-random noise from your device 802BT/802R Video Test Generator User Guide 109 Getting started The HDMI and DVI Analyzer options provide the 802 video test generator with the ability to test and verify the quality of an HDMI or DVI video signal, respectively. Having both a transmitter and receiver, the 802 generator with the Analyzer feature can be used to: • View timing of an HDMI/DVI video signal. Connect an HDMI/DVI source to the HDMI/DVI Rx connector to measure and analyze the timing parameters of the signal. • Generate pseudo-random noise test pattern. Connect an HDMI/DVI host to the HDMI/DVI Tx connector to receive pseudo-random noise for testing purposes. • Analyze pixel data at different frequencies. Examine the quality of HDMI/DVI pixel transmission (including source, cables and distribution systems) for data errors and flickering pixels. • View InfoFrame packets from an HDMI signal. Display and validate InfoFrame packets transmitted from an HDMI source This chapter provides procedures for testing with the analyzer through the front panel and through the command line. Front panel instructions are provided initially for each test. For procedures using the command line refer to “Controlling analyzer using command-line interface” on page 130. HDMI analyzer connections HDMI receiver SS AV Rx HDMI transmitter Tx VGA Audio/Video connector Monitoring HDMI analyzer signal input With the HDMI analyzer option, you can externally monitor the video and/or audio content of an incoming HDMI signal. This feature lets you view and hear HDMI content that is received at the HDMI Rx connector while analysis and testing functions are performed by the analyzer. 110 Chapter 8 Analyzing Digital Sources and Cables To monitor HDMI input: • Use the VGA-to-RCA cable (part 30-00148) to connect the AV connector with a YPbPr display, and the audio connections, as shown below. To AV connector To audio source Red To VGA-to RCA cable To audio player White A VGA-to-RCA (3) cable is available from Quantum Data (part 99-00503), which requires a female-to-female HD15 adapter, which is also available from Quantum Data (part 09-00251). • Use the VGA-to-RCA cable (part 30-00148) to connect the AV connector with an analog VGA display, and the audio connections as shown below. To AV connector To audio source Red To analog display To audio player White DVI analyzer connections The 802 generator with the DVI analyzer option is equipped with two digital DVI connectors. In addition to a DVI Tx (output) connector that emulates a DVI transmit device, a DVI Rx (input) connector is provided that allows a high-quality DVI display to be emulated. SS 802BT/802R Video Test Generator User Guide Tx Rx Transmitter Receiver VGA 111 Starting the Analyzer Setup Utility Use the Analyzer Setup Utility to view or modify the configuration of the analyzer. To start the Analyzer Setup Utility: 1. Start the generator in Digital-Friendly mode (see page 18). 2. Connect a digital display with the DVI or HDMI transmitter on the generator. 3. Select a format supported by the display (see “Selecting formats automatically” on page 25). 4. Select the Analzyer image. The Analyzer Setup Utility appears on the connected display. Note: The Report Setup feature is not implemented. Enabling and disabling analyzer images Certain analyzer tasks require images to be displayed on an HDMI/DVI display. To enable or disable display of analyzer images: 1. Start the Analyzer Setup Utility (see page 112). 2. Press and release the Step key. The Step key illuminates and the Analyzer Images field is highlighted. 112 Chapter 8 Analyzing Digital Sources and Cables 3. Using the Image knob, toggle between ON (to enable analyzer images) and OFF (to disable analyzer images) setting. 4. Press and release the Step key to save the currently displayed parameters. The light on the Step key extinguishes, and the new settings are implemented for Analyzer mode operation. Starting the analyzer The analyzer functions as a special operating mode within the 802 generator. You must place the generator into this mode to perform any analyzer tasks. To put the generator in the analyzer mode: 1. Start the generator in Digital-Friendly mode (see page 18). 2. Press and release the Outputs key. The light on the key extinguishes. 3. While holding down the G key, press and release the Outputs key. The Outputs key illuminates and the following message appears on the LCD. This indicates that the generator is in analyzer mode (example shows DVI analyzer). To take the generator out of the analyzer mode: 1. Press and release the Outputs key. The generator is returned to the normal mode as a signal source. The LCD shows the format and image currently active. 802BT/802R Video Test Generator User Guide 113 Measuring timing of video signal The analyzer provides the ability to analyze signal timing information of an external HDMI/DVI source device. This feature allows you to test a transmitted HDMI/DVI signal for anomalies and verify that the proper timing is output by the HDMI/DVI transmitter for a given signal format. The procedures below provide instructions for configuring the analyzer through the front panel. Note that you can also measure timing with the analyzer through the command line. For procedures using the command line refer to “Signal timing analysis commands” on page 130. The analyzer provides two measurement methods: • Basic timing measurement – Displays limited measurements on LCD. • Detailed timing measurement – Displays detailed measurements on a display connected with the generator. The procedures below provide instructions for configuring the analyzer through the front panel. Note that you can also measure timing with the analyzer through the command line. For procedures using the command line refer to “Signal timing analysis commands” on page 130. Setting up analyzer to measure timing To operate the analyzer, you must select the desired HDMI/DVI signal source and set signal format settings and parameters. To set HDMI/DVI signal source parameters: 1. Start the Analyzer Setup Utility (see page 112). 2. Press and release the Step key. The Step key illuminates and the Analyzer Images field is highlighted. 3. Using the Format knob, select the Auto Based On field. 4. If using the HDMI/DVI signal originating internally from the generator, follow these steps: a. Using the Image knob, select CURRENT in the highlighted field. b. Using the Format knob, select the Format field. c. Select the desired signal format number using the cursor (displayed under a digit in the field) as follows: • 114 To move the cursor between digits, press the R and G keys. Chapter 8 Analyzing Digital Sources and Cables • To select a number for a digit, turn the Image knob. As the number in the Format field changes, the appropriate timing parameters for the selection appear in the box under the Format Parameters field. 5. If using an HDMI/DVI signal originating externally from the generator, follow these steps: a. Select MEASURED in the highlighted field. b. Select the Format Parameters field using the Format knob. c. Capture the external signal’s timing parameters by pressing and releasing the B key. d. Configure the HDMI/DVI transmit device to output an HDMI/DVI signal. After a few seconds, the external signal’s timing parameters are displayed in the box under Format Parameters and in the Run Length(Hex) field. Important: If the external source signal’s timing parameters change (or the field selection is changed), the signal timing parameters must be recaptured. 6. Press and release the Step key to save the currently displayed parameters. The light on the Step key extinguishes, and the new settings are implemented for analyzer mode operation. Measuring basic timing parameters To view basic timing information of an external HDMI/DVI source signal: 1. Connect the HDMI/DVI transmit device to the HDMI/DVI Rx connector on the generator. 2. If necessary, set the proper HDMI/DVI signal source parameters within the generator. • See “Starting the Analyzer Setup Utility” on page 112 for steps on viewing the current analyzer configuration. • To edit HDMI/DVI signal source parameters, see “Setting up analyzer to measure timing” on page 114. 3. If desired, monitor the video signal received on the HDMI Rx connector (see page 110). 4. Start the analyzer (see “Starting the analyzer” on page 113). 5. Press and release the R key to display the horizontal and vertical frequencies of the HDMI/DVI signal on the LCD (see example below). HS rate 48076 VS rate 72.188 802BT/802R Video Test Generator User Guide 115 6. Press the G key to display the following format parameters on the LCD. Horizontal pulse width (pixels) Vertical pulse delay (pixels) Active pixels per line Horizontal period (pixels) 1040 800 666 600 56 120 37 6 Vertical period (lines) Active lines Horizontal pulse delay (pixels) Vertical pulse width (pixels) Measuring detailed timing parameters The analyzer can analyze detailed HDMI/DVI signal timing information. The timing information is displayed on an HDMI/DVI display connected to the generator. To view detailed timing information of an external HDMI/DVI source signal: 1. Connect the HDMI/DVI transmit device to the HDMI/DVI Rx connector on the generator. 2. Connect an HDMI/DVI display to the HDMI/DVI Tx connector on the generator. 3. If necessary, set the proper HDMI/DVI signal source parameters within the generator. • See “Starting the Analyzer Setup Utility” on page 112 for steps on viewing the current analyzer configuration. • To edit HDMI/DVI signal source parameters, see “Setting up analyzer to measure timing” on page 114. 4. If desired, monitor the video signal received on the HDMI Rx connector (see page 110). 5. Using the Format knob, select an appropriate format for the connected HDMI/DVI display. Note: To automatically configure the Format knob list based on the EDID structure of a DDC-compliant display, hold down the R key, then press and release the ACS key. 116 Chapter 8 Analyzing Digital Sources and Cables 6. Using the Image knob, select the FormatRx image. Detailed timing information of the HDMI/DVI signal is displayed on the HDMI/DVI display (as shown in the example below). 802BT/802R Video Test Generator User Guide 117 Testing cables and distribution systems This section describes how to test HDMI or DVI cables, and distribution systems using pseudo-random noise. Using different signal formats, the HDMI/DVI cable can be tested over a wide range of frequencies. The procedures below provide instructions for testing cable and distribution systems with the analyzer through the front panel. Note that you can also perform these procedures through the command line. For procedures using the command line refer to “Analyzing pseudo-random noise in a cable or distribution system” on page 133. To test a cable or distribution system: 1. Connect the HDMI/DVI cable to be tested between the HDMI/DVI Tx and Rx connectors on the generator. Note: If you are testing a fiber optic cable, plug the fiber optic cable connector marked “transmitter” to the HDMI/DVI Tx connector on the generator, and plug the connector marked “receiver” to the HDMI/DVI Rx connector on the generator. Use a 5 Vdc power supply adapter at the receiver side of the cable. 2. If necessary, set the proper HDMI/DVI signal source and pseudo-random noise parameters within the generator. • See “Starting the Analyzer Setup Utility” on page 112 for steps on viewing the current analyzer configuration. • You will have to configure the analyzer for an internal source. To edit HDMI/DVI signal source parameters, see “Setting up analyzer to measure timing” on page 114. Note: The HDMI/DVI signal source must be set to internal (Auto Based On field set to CURRENT) for this procedure. • For information on what values to set the pseudo-random noise parameters as well as instructions on how to set them, see “Setting pseudo-random noise parameters” on page 142. 3. (HDMI only) If desired, monitor the video signal received on the HDMI Rx connector (see “Monitoring HDMI analyzer signal input” on page 110). 118 Chapter 8 Analyzing Digital Sources and Cables 4. Using the Format knob, select the signal format you want to use. Any built-in formats may be used for this test. However, we recommend using several formats spread over a wide range of frequencies. For example, the Test165 format is commonly used to test at the maximum pixel frequency (165 MHz), while the DMT0660 format can be used to test at a very low frequency (25.175 MHz).Use the following formats to test single-link DVI over a range of frequencies: Format Pixel rate (Mhz) TEST165 165.000 DMT1660 162.000 DMT1285G 157.500 DMT1285A 148.500 DMT1648 135.000 DMT1275A 129.600 DMT1185 121.500 DMT1260G 108.000 DMT1085 94.500 DMT1170 94.200 DMT1075 78.750 DMT1070 75.000 720p60 74.250 DMT1060 65.000 DMT0885 56.250 DMT0872 50.000 DMT0875 49.500 DMT1043 44.900 DMT0860 40.000 DMT0685 36.000 DMT0785H 35.500 DMT0675 31.500 SMT0760V 28.322 DMT0660 25.175 5. Start the analyzer (see “Starting the analyzer” on page 113). 802BT/802R Video Test Generator User Guide 119 6. Press and release the B key to analyze the number of pixel errors detected per color component of the received HDMI/DVI signal on the LCD (see example below). R: G: 0 B: 21 0 To stop the analysis, press and release the B key again. The light on the key extinguishes and the analysis stops. 7. Press and release the ACS key to analyze pixel error rate (in errors per billion) and number of pixels measured (in billions) in the received HDMI/DVI signal on the LCD (see example below). Note: When the number of pixel errors becomes very large, the text “Very high” is displayed in the bottom row of the LCD (replacing the numbers). PER: pels/billion 4.255 0.88 To stop the analysis, press and release the ACS key again. The light on the key extinguishes and the analysis stops. 8. Press and release the DCS key to view the expected and measured values for the first pixel error detected from the received HDMI/DVI signal (see example below). original: 40018C 1st error: FFFFFF To stop the analysis, press and release the DCS key again. The light on the key extinguishes and the analysis stops. 9. To test the cable at a different frequency, return to step 4. Testing accuracy of analyzer You can verify the analyzer’s ability to correctly analyze pseudo-random noise. The procedures below provide instructions for testing the accuracy of the analyzer through the front panel. Note that you can also perform these procedures through the command line. For procedures using the command line refer to “Testing the analyzer” on page 134. To verify the analyzer’s pseudo-random noise analysis capability: 1. Connect the HDMI/DVI Tx connector to an HDMI/DVI display. 2. Using the Format knob, select an appropriate format for the connected HDMI/DVI display. 120 Chapter 8 Analyzing Digital Sources and Cables Note: To automatically configure the Format knob list based on the EDID structure of a DDC-compliant display, hold down the R key, and then press and release the ACS key. 3. If necessary, set the proper HDMI/DVI signal source parameters within the generator. • See “Starting the Analyzer Setup Utility” on page 112 for steps on viewing the current analyzer configuration. • You will have to configure the analyzer for an internal source. To edit HDMI/DVI signal source parameters, see “Setting up analyzer to measure timing” on page 114. 4. Configure pseudo-random noise parameters to implement a single pseudo-random noise test sequence. This requires setting the Procedure field to SINGLE SHOT. • To edit pseudo-random noise parameters, see “Setting pseudo-random noise parameters” on page 142. 5. Disconnect the HDMI/DVI Tx connector from the HDMI/DVI display. 6. Connect an HDMI/DVI cable between the HDMI/DVI Tx and Rx connectors on the generator. 7. Using the Format knob, select the signal format you want to use. • Any of the pre-defined formats can be used for this test for DVI. However, we recommend using the Test165 format to test DVI at the maximum pixel frequency (165MHz). For HDMI the Test81 format should be used. Note: In order to access the test formats such as Test165, you may have to re-invoke the default format list by applying pressing and holding the R key and then pressing and releasing the ACS key. 8. Using the Image knob, select either the PRN_5 or PRN_9 image. 9. Start the analyzer (see “Starting the analyzer” on page 113). 10. Press and release the B key to analyze number of pixel errors detected per color component of the received HDMI/DVI signal on the LCD (see example below). • If you selected the PRN_5 image, the following should be displayed (5 errors in each color component). R: G: 5 • B: 5 5 If you selected the PRN_9 image, the following should be displayed (9 errors in each color component). R: G: 9 802BT/802R Video Test Generator User Guide B: 9 9 121 11. To verify accuracy using a different frequency, halt the analyzer mode and return to step 7. 122 Chapter 8 Analyzing Digital Sources and Cables Measuring pixel errors In cases where the external HDMI/DVI device cannot generate pseudo-random noise, a “delta error” testing capability is provided that allows analysis for flickering pixels in a still-frame test image. With the video signal connected to the analyzer input, signal quality can be measured blindly and test results delivered in simple numeric terms. The procedures below provide instructions through the front panel. Note that you can also configure the analyzer to measure pixel errors through the command line. For procedures using the command line refer to “Pseudo-random noise generation commands” on page 132. Setting delta error patch parameters To enable and configure delta error patch testing by the analyzer, you must set certain analyzer parameters properly. Use the procedure to configure the analyzer to test for delta error patch testing. To set delta error patch testing parameters: 1. Start the Analyzer Setup Utility (see page 112). 2. If necessary, see “Setting up analyzer to measure timing” on page 114 for steps to configure the appropriate HDMI/DVI signal source and timing parameters. 3. Press and release the Step key. The Step key illuminates and the Analyzer Images field is highlighted. 4. Using the Format knob, select the Delta Error Patch Setup field. 5. Using the Image knob, specify whether to enable (ON) or disable (OFF) delta error patch. If set to OFF, delta error patch is disabled and all associated fields are disabled. 6. Using the Format knob, select the Travel field. 7. Using the Image knob, specify how you want the patch to move across the display as follows: • Select Zig Zag to move over the active video in a zig zag fashion. • Select FIXED to move over the active video in a fixed position. 8. Using the Format knob, select the Parameters field. 9. Using the Image knob, specify how you want the delta error patch implemented as follows: • Select AUTO to allow the generator to automatically set the patch settings. The patch width and height are calculated based on size of the active video area. 802BT/802R Video Test Generator User Guide 123 • Select MANUAL to define specific patch settings. 10. To define specific settings for delta error patch (width, height, and position), follow these steps: a. Using the Format knob, select the Width, Height, X, or Y field. Note: If you selected AUTO in the Parameters field and the HDMI/DVI signal source is internal (Auto Based On field set to CURRENT), the Width and Height fields are not selectable. Similarly, if you selected AUTO in the Parameters field and the HDMI/DVI signal source is external (Auto Based On field set to MEASURE), the Width and Height fields are set when measuring the external signal’s timing parameters (see “Setting up analyzer to measure timing” on page 114). b. c. Set the parameter (in decimal) using the cursor (displayed under a digit in the field) to select the appropriate value as follows: • To move the cursor between digits, press the R and G keys. • To select a number for a digit, turn the Image knob. Repeat these steps until each parameter is defined. 11. Using the Format knob, select the Reference Frame field. 12. Using the Image knob, specify the method used to compare the patch within different frames as follows: • Select FIRST to use the first field as the reference for comparison with other patches in other frames. • Select PAIRS to set the comparison to be performed in each two successive frames. 13. Using the Format knob, select the Frames Compared field. 14. Specify the number of frames to be compared with the patch dimensions using the cursor (displayed under a digit in the field) to select the appropriate value as follows: • To move the cursor between digits, press the R and G keys. • To select a number for a digit, turn the Image knob. 15. Press and release the Step key to save the currently displayed parameters. The light on the Step key extinguishes, and the settings are implemented for Analyzer mode operation. 124 Chapter 8 Analyzing Digital Sources and Cables Measuring pixel errors in patch The analyzer can test and analyze the transmission quality of an external HDMI/DVI transmit device using a delta error patch pattern. The analyzer captures all or a portion of an external image (patch pattern) and verifies that all pixels match over a number of frames. The results are output to an HDMI/DVI display using a special image. To test an external HDMI/DVI signal using delta error patch pattern: 1. Connect the HDMI/DVI transmit device to the HDMI/DVI Rx connector on the generator. 2. Connect an HDMI/DVI display to the HDMI/DVI Tx connector on the generator. 3. If necessary, set the proper HDMI/DVI signal source and delta error patch parameters within the generator. • See “Starting the Analyzer Setup Utility” on page 112 for steps on viewing the current analyzer configuration. • To edit HDMI/DVI signal source parameters, see “Setting up analyzer to measure timing” on page 114. • To edit delta error patch parameters, see “Setting delta error patch parameters” on page 123. 4. (HDMI only) If desired, monitor the video signal received on the HDMI Rx connector (see “Monitoring HDMI analyzer signal input” on page 110). 5. Generate a static image from the HDMI/DVI transmit device. 6. Using the Format knob, select an appropriate format for the connected HDMI/DVI display. Note: To automatically configure the Format knob list based on the EDID structure of a DDC-compliant display, hold down the R key, then press and release the ACS key. 802BT/802R Video Test Generator User Guide 125 7. Using the Image knob, select the DeltaErr image. The DeltaErr image appears on the connected HDMI/DVI display. As shown in the example below, errors are presented in the area in which they are found by color component. 126 Chapter 8 Analyzing Digital Sources and Cables Testing InfoFrames (HDMI only) The HDMI analyzer can analyze InfoFrame data from an incoming HDMI signal. With this capability, an HDMI transmit device can be tested for its ability to transmit InfoFrame packets correctly. Testing HDMI transmit device InfoFrame capability The 802 generator can monitor the InfoFrame content of the received HDMI signal. To view current HDMI InfoFrame contents received from an HDMI transmitter: 1. Connect an HDMIdisplay to the HDMI Tx connector on the generator. 2. Connect the HDMI source to the HDMI Rx connector on the generator. 3. Setup the generator for HDMI output (see page 147). 4. If desired, monitor the video signal received on the HDMI Rx connector (see “Monitoring HDMI analyzer signal input” on page 110). 5. Using the Format knob, select an appropriate format for the connected HDMI/DVI display. Note: To automatically configure the Format knob list based on the EDID structure of a DDC-compliant display, hold down the R key, then press and release the ACS key. 802BT/802R Video Test Generator User Guide 127 6. Using the Image knob, select the PacketRx image. The PacketRx image appears on the connected HDMI display. Shown in the image are the current settings for the AVI InfoFrame input. 7. Press and release the Step key. The Step key illuminates. 8. Using the Image knob, select the appropriate InfoFrame type. The contents of the appropriate InfoFrame input are displayed on the HDMI display. 9. When finished, press and release the Step key. The light on the Step key extinguishes. 128 Chapter 8 Analyzing Digital Sources and Cables Testing audio (HDMI only) The HDMI analyzer can process audio data from an incoming HDMI signal. With this capability, an HDMI source can be tested for its ability to successfully transmit audio packets. Testing HDMI transmit device audio capability The 802 generator can monitor the audio content of the received HDMI signal. To monitor audio content received from an HDMI transmitter: 1. Connect the HDMI transmit device to the HDMI Rx connector on the generator. 2. If necessary, set up the generator for HDMI output (see “Setting up the generator for HDMI operation” on page 147). 3. Monitor the audio signal received on the HDMI Rx connector using an external audio device (see “Monitoring HDMI analyzer signal input” on page 110. 802BT/802R Video Test Generator User Guide 129 Controlling analyzer using command-line interface You can operate the Analyzer using the 802 generator’s command line interface. This section describes Analyzer functions and commands and provides examples of command sequences you can use to perform Analyzer tasks. For command descriptions, see Appendix A, “Command Reference.” Signal timing analysis commands This section provides command line procedures for viewing signal timing parameters. Viewing signal timing parameters (on an HDMI/DVI monitor) This example displays timing and allows you to view real-time, detailed HDMI/DVI signal timing information from a connected HDMI/DVI transmit device. To view basic timing information of an external HDMI/DVI source signal: 1. Connect the HDMI/DVI transmit device to the HDMI/DVI Rx connector on the generator. 2. If desired, monitor the video signal received on the HDMI/DVI Rx connector (see page 110). 3. Using a terminal emulator, establish a terminal connection with the generator. Refer to “Setting up a terminal connection with the generator” on page 14. 4. Enter the following commands to configure the generator to output a digital signal (HDMI or DVI): SROP 2 4 This removes analog friendly mode and configures the generator to output either a DVI or HDMI signal depending on the interface hardware the generator is equipped with (DVI or HDMI). 5. (optional) Enter the following command to set the status display mode: SROP 8 6. Enter the following commands to initiate the measurement of timing parameters. ANIG 1 // enables analyzer images to be displayed IMGL FormatRx // loads the FormatRX image into the edit buffer IMGU // applies the FormatRX image to the generator/analyzer Viewing specific timing parameters The following is an example of using commands to view the total number of horizontal pixels and horizontal frequency of the HDMI/DVI signal. 130 Chapter 8 Analyzing Digital Sources and Cables To view specific timing information of an external HDMI/DVI source signal: 1. Connect the HDMI/DVI transmit device to the HDMI/DVI Rx connector on the generator. 2. Using a terminal emulator, establish a terminal connection with the generator. Refer to “Setting up a terminal connection with the generator” on page 14. 3. Enter the following commands to configure the generator to output a digital signal (HDMI or DVI): SROP 2 4 This removes analog friendly mode and configures the generator to output either a DVI or HDMI signal depending on the interface hardware the generator is equipped with (DVI or HDMI). 4. (optional) Enter the following command to set the status display mode: SROP 8 5. Enter the following commands to initiate the measurement of timing parameters. PNSF 1 TMAU HTOT? HRES? // // // // selects the source of timing information as “Measured” initiates measurement of timing from external source queries for the horizontal total pixels queries for the horizontal active pixels See page 548 for additional parameters you can query. 802BT/802R Video Test Generator User Guide 131 Pseudo-random noise generation commands This section provides command line procedures for generating pseudo-random noise. Generating pseudo-random noise The following is an example of using commands to first configure and then generate pseudo-random noise. To generate pseudo-random noise: 1. Using a terminal emulator, establish a terminal connection with the generator. Refer to “Setting up a terminal connection with the generator” on page 14. 2. Enter the following commands to configure the generator to output a digital signal (HDMI or DVI): SROP 2 4 This removes analog friendly mode and configures the generator to output either a DVI or HDMI signal depending on the interface hardware the generator is equipped with (DVI or HDMI). 3. (optional) Enter the following command to set the status display mode: SROP 8 4. Enter the following commands to generate pseudo-random noise. PNSF PNST PNSA PNSM PNSP PNSG PNGU 0 1 1 0 0 1 // // // // // // // // selects internal timing source for pseudo-random noise specifies QDI-BCM algorithm sets pseudo random noise to be calculated each pixel clock sets pseudo random noise test to run in auto mode sets procedure for pseudo-random noise test to “continuous” enables the pseudo-random noise test turns on the pseudo-random noise test a carriage return halts the continuous test 5. Enter the following commands to stop pseudo-random noise generation. PNSG 0 PNGU Pseudo-random noise analysis commands This section provides command line procedures for generating pseudo-random noise and analyzing the received data. 132 Chapter 8 Analyzing Digital Sources and Cables Analyzing pseudo-random noise in a cable or distribution system The following example uses commands to test a connected HDMI/DVI cable or distribution system. To analyze pseudo-random noise in a cable or distribution system: 1. Connect the DVI or HDMI cable between the transmit and receive connectors on the generator. If you are testing a distribution system connect an access cable to the distribution center to the transmit connector on the generator and a second access cable to the receive connector on the generator. 2. Using a terminal emulator, establish a terminal connection with the generator. Refer to “Setting up a terminal connection with the generator” on page 14. 3. Enter the following commands to configure the generator to output a digital signal (HDMI or DVI): SROP 2 4 This removes analog friendly mode and configures the generator to output either a DVI or HDMI signal depending on the interface hardware the generator is equipped with (DVI or HDMI). 4. (optional) Enter the following commands to set the status display mode: SROP 8 5. Enter the following commands to analyze pseudo-random noise in a cable or distribution system. FMTL TEST165 // loads the TEST165 format for testing DVI Note: For HDMI testing load the TEST81 format. FMTU // applies the TEST165 or TEST81 format to the generator 6. Enter the following commands to configure the pseudo-random noise parameters. PNSF PNST PNSA PNSM PNSP PNAU 0 1 1 0 100 // // // // // // selects internal timing source for pseudo-random noise specifies QDI-BCM algorithm sets pseudo random noise to be calculated each pixel sets pseudo random noise test to run in auto mode sets pseudo-random noise for 100 “multi-shots” loads the generator with pseudo-random noise settings Note: The test will stop automatically if configured to run in the single or multi-shot mode. If you initiate the test in the continuous mode, you will have to enter a carriage return to halt the test after PNAU is invoked. 7. Enter the following commands to view the results of the test. 802BT/802R Video Test Generator User Guide 133 GPER? GNPT? GCET? GFED? // // // // returns returns returns returns the pixel error rate in errors per billion the number of pixels measured in billions the number of bad pixels for R, G, B components information about the first error encountered Analyzing pseudo-random noise from an external source The following example tests an HDMI/DVI transmit device’s pixel data using pseudo-random noise generated by an external source. To analyze pseudo-random noise from an external source: 1. Connect the DVI or HDMI cable between the receive connector on the generator and the output interface on the device under test. 2. Using a terminal emulator, establish a terminal connection with the generator. Refer to “Setting up a terminal connection with the generator” on page 14. 3. Enter the following commands to configure the generator to output a digital signal (HDMI or DVI): SROP 2 4 This removes analog friendly mode and configures the generator to output either a DVI or HDMI signal depending on the interface hardware the generator is equipped with (DVI or HDMI). 4. (optional) Enter the following commands to set the status display mode: SROP 8 5. Enter the following commands to configure the pseudo-random noise parameters. PNSF PNST TMAU PNSA PNSM PNSP PNAU 1 1 1 0 100 // // // // // // // selects external timing source for pseudo-random noise specifies QDI-BCM algorithm initiates measurement of timing from external source sets pseudo random noise to be calculated each pixel sets pseudo random noise test to run in auto mode sets pseudo-random noise for 100 “multi-shots” loads the generator with the pseudo-random noise settings Note: The test will stop automatically if configured to run in the single or multi-shot mode. If you initiate the test in the continuous mode, you will have to enter a carriage return to halt the test after PNAU is invoked. 6. Enter the following commands to view the results of the test. GPER? GNPT? GCET? GFED? // // // // returns returns returns returns the pixel error rate in errors per billion the number of pixels measured in billions the number of bad pixels for R, G, B components information about the first error encountered Testing the analyzer The following example verifies the analyzer’s pseudo-random noise analysis capability. 134 Chapter 8 Analyzing Digital Sources and Cables To verify the analyzer’s pseudo-random noise analysis capability: 1. Using a terminal emulator, establish a terminal connection with the generator. Refer to “Setting up a terminal connection with the generator” on page 14. 2. Enter the following commands to configure the generator to output a digital signal (HDMI or DVI): SROP 2 4 This removes analog friendly mode and configures the generator to output either a DVI or HDMI signal depending on the interface hardware the generator is equipped with (DVI or HDMI). 3. (optional) Enter the following commands to set the status display mode: SROP 8 4. Connect an HDMI/DVI cable between the HDMI/DVI Tx and Rx connectors on the generator. 5. Enter the following commands to select the signal format and image. FMTL TEST165 // loads the TEST165 format Note: For HDMI testing load the TEST81 format. FMTU IMGL PRN_9 IMGU // applies the TEST165 or TEST81 format to the generator // loads the PRN_9 image // activates the image in the generator 6. Enter the following commands to set the pseudo-random noise parameters. PNSF PNST PNSA PNSM PNAU 0 1 1 0 // // // // // selects internal timing source for pseudo-random noise specifies QDI-BCM algorithm sets pseudo random noise to be calculated each pixel sets pseudo-random noise test to “single-shot” loads the generator with pseudo-random noise settings Note: The test will stop automatically if configured to run in the single or multi-shot mode. If you initiate the test in the continuous mode, you will have to enter a carriage return to halt the test after PNAU is invoked. 7. Enter the following commands to view the results of the test. GPER? GNPT? GCET? GFED? // // // // returns returns returns returns the pixel error rate in errors per billion the number of pixels measured in billions the number of bad pixels for R, G, B components information about the first error encountered Analyzing pixel data (delta error patch) The following is an example of using commands to test an HDMI/DVI transmit device’s pixel data using a delta error patch test. 802BT/802R Video Test Generator User Guide 135 To set delta error patch testing parameters: 1. Using a terminal emulator, establish a terminal connection with the generator. Refer to “Setting up a terminal connection with the generator” on page 14. 2. Enter the following commands to configure the generator to output a digital signal (HDMI or DVI): SROP 2 4 This removes analog friendly mode and configures the generator to output either a DVI or HDMI signal depending on the interface hardware the generator is equipped with (DVI or HDMI). 3. (optional) Enter the following commands to set the status display mode: SROP 8 4. Connect the HDMI/DVI transmit device to the HDMI/DVI Rx connector on the generator. 5. Connect an HDMI/DVI display to the HDMI/DVI Tx connector on the generator. 6. Enter the following commands to load a suitable format for the display under test. FMTL DMT0660 // loads the DMT0660 format for testing FMTU // applies the DMT0660 format to the generator 7. Enter the following commands to load a suitable static image. IMGL FLAT IMGU // loads the static image for testing // applies the image to the generator 8. Enter the following commands to configure the delta patch parameters. 9. PDSX PDSY PDSH PDSW 128 256 64 96 // // // // sets sets sets sets patch patch patch patch starting at x-pixel 128 starting at y-pixel 256 height at 64 pixel width at 90 pixels 10. Enter the following commands to run the delta patch test. PDAU ANIG 1 IMGL DeltaErr IMGU 136 // // // // captures patch of image enables analyzer images loads the DeltaErr image activates the image in the generator Chapter 8 Analyzing Digital Sources and Cables Generating pseudo-random noise from your device This section explains how to implement pseudo-random noise is your own device. Implementing pseudo-random noise from your device The analyzer can test and analyze pixel data received from an HDMI/DVI source. To accomplish this, a pseudo-random noise pattern is used that provides a sequence of highly dynamic pixel values. To maximize your ability to analyze pixel data generated by set-top boxes, you must be able to generate pseudo-random noise. To facilitate this, you can use the lfsr.h and lfsl.cpp source code files from http://www.quantumdata.com/support/resources/pr_noise/QDI-BCM_PseudoNoise.ZIP, which enable you to generate QDI-BCM pseudo-random noise from your device. Once implemented, you can verify that the code is implemented correctly by using the Dump10K() function to write the first 10,000 pixel values to a file. This result should match the contents of the PN_31_24.txt reference file included in http://www.quantumdata.com/support/resources/pr_noise/QDI-BCM_PseudoNoise.ZIP. lfsr.h The following source code is provided for the lfdr.h file. // LFSR.h: interface for the CLFSR class. #if !defined(AFX_LFSR_H__5947F6F9_1DBE_4E6E_9AFB_77D5D8857A10__INCLUDED_) #define AFX_LFSR_H__5947F6F9_1DBE_4E6E_9AFB_77D5D8857A10__INCLUDED_ #if _MSC_VER > 1000 #pragma once #endif // _MSC_VER > 1000 class CLFSR { public: void Dump10K(); unsigned long GetPixel(); void Reset(); CLFSR(); virtual ~CLFSR(); protected: int state; unsigned long seed; }; 802BT/802R Video Test Generator User Guide 137 #endif // !defined(AFX_LFSR_H__5947F6F9_1DBE_4E6E_9AFB_77D5D8857A10__INCLUDED_) lfsl.cpp The following source code is provided for the tfsl.cpp file. // Implementation of the CLFSR class #include “LFSR.h” #include #ifdef _DEBUG #undef THIS_FILE static char THIS_FILE[]=__FILE__; #define new DEBUG_NEW #endif // enable this to light up pixels 1,2,3 as red,green,blue // in horizontal order // Pixel 1 represents the top left corner of the screen // when this is enabled, all other pixels are black //#define RGB_TEST // Construction/Destruction unsigned long pixelvalue; CLFSR::CLFSR() { } CLFSR::~CLFSR() { } void CLFSR::Reset() { state=0; seed=0x08000001; } // Pixel 1 should be 0x000000 // Pixel 2 should be 0x00 (7-bits) , Opcode(10-bits), SeedHigh(7 bits) // Pixel 3 should be SeedLow (24 bits) // All other pixels are then set based on the results of the LFSR calculations. // The 10-bit Opcode is custom per Quantum Data’s request and it will be set to ‘00,0000,0111’. unsigned long CLFSR::GetPixel() { unsigned long temp; 138 Chapter 8 Analyzing Digital Sources and Cables // states 0 to 2 are specific for QuantumData switch (state) { // pixel 1 case 0: pixelvalue=seed; state++; #ifdef RGB_TEST return (0xff0000); // red #else return(0); #endif break; // pixel 2 case 1: temp=((0x007<<7) | (( seed &0x7f000000)>>24)) & 0xffffff; state++; #ifdef RGB_TEST return (0x00ff00); // green #else return(temp); #endif break; // pixel 3 case 2: temp=seed &0x00ffffff; state++; #ifdef RGB_TEST return (0x0000ff); // blue #else return(temp); #endif break; default: pixelvalue= ((pixelvalue & 0x7f)<<24) | ( ((pixelvalue>>4) & 0xffffff) ^ ((pixelvalue>>7) & 0xffffff) ); #ifdef RGB_TEST return (0x0); // blank #else return(pixelvalue & 0xffffff); #endif break; break; } 802BT/802R Video Test Generator User Guide 139 } void CLFSR::Dump10K() { int i; FILE* f; char s[100]; f=fopen(“c:\\temp\\noise.txt”,”w”); Reset(); for (i=0;i<10000;i++) { sprintf(s,”%.6lx”,GetPixel()); fprintf(f,”%s\r\n”,s); } // AfxMessageBox(“See c:\\temp\\noise.txt”); fclose(f); Sending pseudo-random noise to external device The analyzer can be the source for a pseudo-random noise test pattern. HDMI/DVI displays can use this test pattern for testing and analysis purposes. To generate a pseudo-random noise test pattern: 1. Connect the HDMI/DVI receiver device to the HDMI/DVI Tx connector on the generator. 2. If necessary, set the proper pseudo-random noise parameters within the generator. • See “Starting the Analyzer Setup Utility” on page 112 for steps on viewing the current analyzer configuration. • To edit pseudo-random noise parameters, see “Setting pseudo-random noise parameters” on page 142. 3. Place the generator in HDMI/DVI analyzer mode. • See “Starting the analyzer” on page 113 for steps on launching analyzer mode. 4. Press and release the Step key to generate pseudo-random noise to be transmitted. The key illuminates and pseudo-random noise is transmitted from the HDMI/DVI Tx connector. The following message appears on the LCD: Generating Psudo Random Noise 5. To stop pseudo-random noise generation, press and release the Step key. The light on the key extinguishes and pseudo-random noise is no longer transmitted. 140 Chapter 8 Analyzing Digital Sources and Cables Analyzing noise from an external device The analyzer can test and analyze the transmission quality of an external HDMI/DVI transmit device using pseudo-random noise. Important: To perform this test, the external HDMI/DVI transmit device must be able to generate pseudo-random noise using the QDI-BCM format. Note: Before performing this test, you may first want to test the cables and distribution equipment used to transport the HDMI/DVI signal between the external device and generator. For more information, see “Testing cables and distribution systems” on page 118. To test an external HDMI/DVI signal using pseudo-random noise: 1. Connect the HDMI/DVI transmit device to the HDMI/DVI Rx connector on the generator. 2. If necessary, set the proper HDMI/DVI signal source and pseudo-random noise parameters within the generator. • See “Starting the Analyzer Setup Utility” on page 112 for steps on viewing the current analyzer configuration. • To edit HDMI/DVI signal source parameters, see “Setting up analyzer to measure timing” on page 114. Note: The HDMI/DVI signal source must be set to external (Auto Based On field set to MEASURED) for this procedure. • To edit pseudo-random noise parameters, see “Setting pseudo-random noise parameters” on page 142. 3. If desired, monitor the video/audio signal received on the HDMI Rx connector (see “Monitoring HDMI analyzer signal input” on page 110). 4. Start the analyzer (see page 113). 5. Generate pseudo-random noise from the HDMI/DVI transmit device. 6. Press and release the B key to analyze the number of pixel errors detected per color component of the received HDMI/DVI signal (see example below). R: G: 0 B: 21 0 To stop the analysis, press and release the B key again. The light on the key extinguishes and the analysis stops. 802BT/802R Video Test Generator User Guide 141 7. Press and release the ACS key to analyze pixel error rate (in errors per billion) and number of pixels measured (in billions) in the received HDMI/DVI signal on the LCD (see example below). PER: pels/billion 4.255 0.88 Note: When the number of pixel errors becomes very large, the text “Very high” is displayed in the bottom row of the LCD (replacing the numbers). To stop the analysis, press and release the ACS key again. The light on the key extinguishes and the analysis stops. 8. Press and release the DCS key to analyze the expected and reported values for the first pixel error detected from the received HDMI/DVI signal on the LCD (see example below). original: 40018C 1st error: FFFFFF To stop the analysis, press and release the DCS key again. The light on the key extinguishes and the analysis stops. Setting pseudo-random noise parameters This section describes how to modify the pseudo-random noise output by the generator. To set pseudo-random noise parameters: 1. Start the Analyzer Setup Utility (see “Starting the Analyzer Setup Utility” on page 112). 2. If necessary, see “Setting up analyzer to measure timing” on page 114 for steps to configure the appropriate HDMI/DVI signal source and timing parameters. 3. Press and release the Step key. The Step key illuminates and the Analyzer Images field is highlighted. 4. Using the Format knob, select the Pseudo Random Noise Setup field. 5. Using the Image knob, specify whether to enable (ON) or disable (OFF) pseudo-random noise. If set to OFF, pseudo-random noise is disabled and all associated fields are disabled. 6. Using the Format knob, select the Advance after Every field. 7. Using the Image knob, specify how you want pseudo-random noise generated, as follows: 142 Chapter 8 Analyzing Digital Sources and Cables • Select PIXEL to generate and receive pseudo-random noise at every pixel within the whole frame. • Select ACTIVE PIXEL to generate and receive pseudo-random noise only at active pixels within the frame. 8. Using the Format knob, select the Parameters field. 9. Using the Image knob, specify how you want the pseudo-random noise seed and sequence length implemented, as follows: • Select AUTO to use the default seed value and sequence length. The default settings ensure a stable, pseudo-random noise image. If you select this setting, proceed to step 11. • Select MANUAL to define specific seed value and sequence length settings. If you select this setting, proceed to step 10. Note: If the HDMI/DVI signal source is external (Auto Based On field set to MEASURED), you cannot manually define these settings. The Parameters and Seed Value(Hex) fields appear dimmed, and the Run Length(Hex) field is set when measuring the external signal’s timing parameters (see “Setting up analyzer to measure timing” on page 114). 10. If you set the Parameters field to MANUAL, define specific settings for pseudo-random noise seed and sequence length by following these steps: a. Using the Format knob, select the Seed Value(Hex) field. b. c. Specify the desired seed value using the cursor (displayed under a digit in the field) to select the appropriate value as follows: • To move the cursor between digits, press the R and G keys. • To select a number for a digit, turn the Image knob. Using the Format knob, select either the Run-Length(Hex) or Run-Length(Dec) field. d. Specify the desired sequence length value in hexidecimal (if Run-Length(Hex) field is highlighted) or decimal (if Run-Length(Dec) field is highlighted) using the cursor (displayed under a digit in the field) to select the appropriate value as follows: • To move the cursor between digits, use the R and G keys. • To select a number for a digit, use the Image knob. 11. Using the Format knob, select the Procedure field. 12. Using the Image knob, select the sequence type for pseudo-random noise to be generated and tested as follows: • Select CONTINUOUS to run the pseudo-random noise sequence continuously. • Select SINGLE SHOT to run one sequence of pseudo-random noise. 802BT/802R Video Test Generator User Guide 143 • Select MULTI SHOT to define a specific number of sequences to run. Define the number of sequences to run in the field next to the Procedure field. 13. Press and release the Step key to save the currently displayed parameters. The light on the Step key extinguishes, and the settings are implemented for analyzer mode operation. 144 Chapter 8 Analyzing Digital Sources and Cables 9 Testing HDMI Sink Devices Topics in the chapter: • Overview • HDMI connections • Getting started • Testing HDMI video • Testing HDMI audio • Testing HDMI InfoFrames 802BT/802R Video Test Generator User Guide 145 Overview The HDMI option enables the generator to test HDMI-compliant sink devices. With the HDMI option, the generator outputs HDMI-compatible TMDS video and data packets containing audio and auxiliary information. The HDMI option includes the following features: • Advanced E-EDID parsing • Generation of all EIA/CEA-861-B formats below 165 MHz (with all possible variations) • Pixel repetition test capabilities • Internal sine wave generator and external SPDIF audio input for audio testing • AFD test capabilities • Automatic and manual InfoFrame configuration Note: This chapter refers to the EIA/CEA-861B standard, which may be purchased from http://global.ihs.com/ For HDMI compliance testing procedures, see “Testing EDID in HDMI sink device for HDMI compliance” on page 173. 146 Chapter 9 Testing HDMI Sink Devices Getting started This section provides basic information on how to operate the 802 generator using the HDMI option. HDMI connections The generator with the HDMI option has two connectors. In addition to an HDMI Tx (output) connector that emulates an HDMI source device, an AV connector allows external SPDIF audio to be input to the HDMI signal. To use the AV port, an RCA-to-VGA cable is included with the generator. The following figure shows the location of these connectors on a model 802 generator with the HDMI option. Audio/Video connector SS AV HDMI transmitter Tx VGA Setting up the generator for HDMI operation To perform testing using the HDMI option, you must ensure that the generator is configured to output HDMI signals: To set up the generator to perform HDMI testing: 1. Hold down the G and B keys, and then power on the generator. The following message appears on the front panel LCD. Special: keys Digital friendly 2. Release the G and B keys. The generator is placed in Digital Friendly mode. 802BT/802R Video Test Generator User Guide 147 3. Hold down the R and ACS keys, and then cycle the power to the generator. The following message appears on the front panel LCD. Special: keys hot-plug formats 4. Release the R and ACS keys. The generator is placed in Hot-Plug Format mode. This loads the Format knob list with formats supported by the connected HDMI display (hot-plug formats read via EDID structure of attached display). Note: To toggle between the factory default and hot-plug Format knob lists, press and release the R and ACS keys. Using the factory default Format knob list will disable the generator’s ability to automatically select the appropriate output signal protocol (HDMI or DVI) as performed in step 6. In this case, you must manually select the proper TMDS output signal via Toggle DVI/HDMI key operation (R and G keys). 5. Hold down the Step, G, and B keys while starting the genertor, until Status display appears on the LCD. 6. Release the Step, G, and B keys to enable status display on the generator (see example below). Color space Color depth Video type H31 V60 Format name D8C=DMT0659 0=SMPTE133 Image version Image name The format status on the LCD will indicate whether the unit is outputting HDMI or DVI signal protocol from the Tx connector. An “H” in the format status (H8C in the example above) indicates HDMI output; a “D” in the format status indicates DVI output. Note: With the compliant Hot-plug Formats mode active and a hot-plug detected, the generator automatically selects the appropriate TMDS output signal protocol (HDMI or DVI) for the attached display (via EDID read). 7. If the output signal protocol is DVI, toggle to HDMI protocol by holding down the R key, then pressing and releasing the G key. The format status changes to “H” (from “D”) on the LCD. 148 Chapter 9 Testing HDMI Sink Devices Testing HDMI video This section provides steps on how to test handling of HDMI video signals by an HDMI display. To support HDMI, the generator provides pre-defined formats for every video format specified in the EIA/CEA-861-B standard. These pre-defined formats support all aspects of the HDMI signal (video, audio, and auxiliary data). The following table lists the generator formats used to test support for HDMI (EIA/CEA-861-B) formats. EIA/CEA-861-B Video Identification Code Quantum Data format 1 DMT0659, DMT0660 2 480p59, 480p60, 480p59LH, 480p60LH 3 480p59SH, 480p60SH 4 720p59, 720p60 5 1080i29, 1080i30 6 480i2x29, 480i2x30, 480i2xL1, 480i2xL2 7 480i2xS1, 480i2xS2 8 240p2x_1, 240p2x_2, 240p2x_3, 240p2x_4, 240p2xL1, 240p2xL2, 240p2xL3, 240p2xL4 9 240p2xS1, 240p2xS4, 240p2xS3, 240p2xS4 10 480i4x29, 480i4x30, 480i4xL1, 480i4xL2 11 480i4xS1, 480i4xS2 12 240p4x_1, 240p4x_2, 240p4x_3, 240p4x_4, 240p4xL1, 240p4xL2, 240p4xL3, 240p4xL4 13 240p4xS1, 240p4xS2, 240p4xS3, 240p4xS4 14 480p2x59, 480p2x60, 480p2xL1, 480p2xL2 15 480p2xS1, 480p2xS2 16 1080p59, 1080p60 17 576p50, 576p50LH 18 576p50SH 19 720p50 20 1080i25 21 576i2x25, 576i2xLH 22 576i2xSH 23 288p2x_1, 288p2x_2, 288p2x_3, 288p2xL1, 288p2xL2, 288p2xL3 802BT/802R Video Test Generator User Guide 149 EIA/CEA-861-B Video Identification Code Quantum Data format 24 288p2xS1, 288p2xS2, 288p2xS3 25 576i4x25, 576i4xLH 26 576i4xSH 27 288p4x_1, 288p4x_2, 288p4x_3, 288p4xL1, 288p4xL2, 288p4xL3 28 288p4xS1, 288p4xS2, 288p4xS3 29 576p2x50, 576p2xLH 30 576p2xSH 31 1080p50 32 1080p23, 1080p24 33 1080p25 34 1080p29, 1080p30 Testing HDMI video formats Basic testing requires verifying proper handling of those video formats supported by the HDMI display. Using the table above as a guide, you can verify your display’s support for one or more EIA/CEA-861-B formats. To test an HDMI display using supported HDMI formats: 1. Connect an HDMI display to the Tx connector on the generator. 2. If necessary, set up the generator for HDMI output. • See “Setting up the generator for HDMI operation” on page 147 for steps on setting up the generator for HDMI operation. 3. Using the Format knob, specify the HDMI video format you want to test. 150 Chapter 9 Testing HDMI Sink Devices 4. Using the Image knob, select the Master image. The Master image appears on the connected HDMI display (as shown below). 5. To verify proper handling of the selected HDMI video format, check for the following in the image on the HDMI display: • scrambled raster • jitter • centering • scaling anomalies • resolution patches (for clarity) • sparkling or missing pixels 802BT/802R Video Test Generator User Guide 151 6. Using the Image knob, select the Ramp image. The Ramp image appears on the connected HDMI display (as shown below). 7. To verify proper handling of the selected HDMI video format, check for glitches in the image on the HDMI display. 8. Using the Image knob, select additional images (as desired) to verify proper handling of the selected HDMI video format. 9. To test another HDMI format, return to step 3. Testing HDMI video pixel repetition The EIA/CEA-861-B standard defines a number of progressively-scanned gaming formats which support variable horizontal resolution. These formats maintain a fixed 2880-pixel format timing and use pixel repetition to provide 10 different effective horizontal resolutions. A special blanking scheme further reduces the number of active pixels (to those listed in the table below), thereby providing a horizontal safe area that insures that all of the pixels in a game will be visible on overscanned HDMI displays. To support HDMI gaming format and pixel repetition testing, the generator allows you to sequentially apply pixel repetition (up to 10 times) to a unique image. As the pixel repetition factor is increased, the horizontal resolution of the displayed image will decrease as shown the table below. Pixel repetition factor (image version) 152 Horizontal resolution 0 2880 pixels/line 1 2560 pixels/line 2 1280 pixels/line Chapter 9 Testing HDMI Sink Devices Pixel repetition factor (image version) Horizontal resolution 3 853 pixels/line 4 640 pixels/line 5 512 pixels/line 6 427 pixels/line 7 366 pixels/line 8 320 pixels/line 9 284 pixels/line 10 256 pixels/line To test an HDMI display using HDMI pixel repetition: 1. Connect an HDMI display to the Tx connector on the generator. 2. If necessary, set up the generator for HDMI output. • See “Setting up the generator for HDMI operation” on page 147 for steps on setting up the generator for HDMI operation. 3. Using the Format knob, select the HDMI gaming format you want to test. Note: Gaming formats on the generator have the characters "4x" in their names (such as “480i4x29” or “576i4x25”). For a listing of all HDMI formats, see the table on page 149. 4. Using the Image knob, select the PixelRep image. The PixelRep image appears on the connected HDMI display (as shown below). 5. Press and release the Step key. The Step key illuminates. 802BT/802R Video Test Generator User Guide 153 6. Using the Image knob, select the appropriate image version number (1-10). Note: The image version number correlates with the pixel repetition factor. The pixel repetition factor appears in the center of the image. 7. To verify proper handling of the selected HDMI gaming format, check the following in the image on the HDMI display: • The horizontal active area is resized to the appropriate number of clocked pixels using vertical bars to the left and right of the default (2880 pixel) image. • The white vertical borders and circles in the active area appear thicker. • The white text in the center of the active area appears stretched and bigger. 8. Using the Image knob, select additional pixel repetition factors (as desired) to verify proper handling of the selected HDMI gaming format using variable horizontal resolutions. 9. When finished, press and release the Step key. The light on the Step key extinguishes. 10. To test another HDMI gaming format, return to step 3. 154 Chapter 9 Testing HDMI Sink Devices Testing HDMI audio This section provides steps on how to test handling of audio packets by an HDMI display. Testing can be performed using audio originating from both internal (generator) and external sources. The generator supports both 2-channel SPDIF audio from internal source and external source and up to 8-channel audio from an internal audio source. There are seperate sets of images for testing 2-channel SPDIF audio and 8-channel audio. Testing 2-channel HDMI audio output from internal SPDIF source To support testing of HDMI audio, the 802 generator provides two-channel LPCM audio (using an internally-generated sinewave) at the highest audio sampling rate (48 kHz). Multiple scenarios are provided that allow you to test one or both audio channels at different amplitudes and frequencies, as well as test using the different supported sampling rates. The following table lists the images used to perform HDMI audio testing using an internal audio source. Image Description AudioLR Left and right audio channel output with adjustable amplitude. AudioLRf Left and right audio channel output with adjustable frequency. AudioRAT Left and right audio channel output with adjustable sampling rate. Audio_L Left audio channel output with adjustable amplitude. Audio_Lf Left audio channel output with adjustable frequency. Audio_R Right audio channel output with adjustable amplitude. Audio_Rf Right audio channel output with adjustable frequency. To test an HDMI display using HDMI audio from the generator: 1. Connect an HDMI display to the Tx connector on the generator. 2. If necessary, set up the generator for HDMI output. • See “Setting up the generator for HDMI operation” on page 147 for steps on setting up the generator for HDMI operation. 3. Using the Format knob, select either the DMT0660 or 480i2x29 format. 802BT/802R Video Test Generator User Guide 155 4. Using the Image knob, select the appropriate image (see table above). The image appears on the connected HDMI display. The image shows the current settings for the HDMI audio output. For example, the AudioLR image is shown below. 5. Press and release the Step key. The Step key illuminates. 6. Using the Image knob, adjust the amplitude, frequency, or sampling rate (based on the selected image) of the HDMI audio output. 7. To verify proper HDMI audio handling, check the following on the HDMI display: • Audio is output from the proper channels (left, right, or both). • When amplitude is adjusted, the volume is subsequently changed. • When frequency is adjusted, the pitch is subsequently changed. 8. When finished, press and release the Step key. The light on the Step key extinguishes. 9. To test another HDMI audio output type, return to step 4. 156 Chapter 9 Testing HDMI Sink Devices Testing 8-channel HDMI audio output from internal source To support testing of HDMI audio, the 802 generator provides 8-channel LPCM audio (using an internally-generated sinewave) at the highest audio sampling rate (192 kHz). Multiple scenarios are provided that allow you to test one or both audio channels at different amplitudes and frequencies, as well as test using the different supported sampling rates. The following table lists the images used to perform HDMI audio testing using an internal audio source. Image Description Audio_1 Channel 1 output with adjustable amplitude. Audio_1f Channel 1 output with adjustable frequency. Audio_2 Channel 2 output with adjustable amplitude. Audio_2f Channel 2 output with adjustable frequency. Audio_3 Channel 3 output with adjustable amplitude. Audio_3f Channel 3 output with adjustable frequency. Audio_4 Channel 4 output with adjustable amplitude. Audio_4f Channel 4 output with adjustable frequency. Audio_5 Channel 5 output with adjustable amplitude. Audio_5f Channel 5 output with adjustable frequency. Audio_6 Channel 6 output with adjustable amplitude. Audio_6f Channel 6 output with adjustable frequency. Audio_7 Channel 7 output with adjustable amplitude. Audio_7f Channel 7 output with adjustable frequency. Audio_8 Channel 8 output with adjustable amplitude. Audio_8f Channel 8 output with adjustable frequency. To test an HDMI display using HDMI 8-channel audio from the generator: 1. Connect an HDMI display to the Tx connector on the generator. 2. If necessary, set up the generator for HDMI output. • See “Setting up the generator for HDMI operation” on page 147 for steps on setting up the generator for HDMI operation. 3. Using the Format knob, select either the DMT0660 or 480i2x29 format. 802BT/802R Video Test Generator User Guide 157 4. Using the Image knob, select the appropriate image (see table above). The image appears on the connected HDMI display. The image shows the current settings for the HDMI audio output. For example, the Audio_1 image is shown below. 5. Press and release the Step key. The Step key illuminates. 6. Using the Image knob, adjust the amplitude or frequency (based on the selected image) of the HDMI audio output. 7. To verify proper HDMI audio handling, check the following on the HDMI display: • Audio is output from the proper channels. • When amplitude is adjusted, the volume is subsequently changed. • When frequency is adjusted, the pitch is subsequently changed. 8. When finished, press and release the Step key. The light on the Step key extinguishes. 9. To test another HDMI audio output type, return to step 4. Testing HDMI audio using an external audio source The generator provides basic, two-channel LPCM audio signals. However, it can encode multichannel audio signals from an external SPDIF source (such as a DVD player) with the HDMI content stream. 158 Chapter 9 Testing HDMI Sink Devices To test an HDMI display using HDMI audio from an external source: 1. Connect an HDMI display to the Tx connector on the generator. 2. Connect the external audio source to the AV connector on the generator using the RCA-to-VGA cable (part 30-00148) provided with the generator, as shown below: To AV connector To audio source Red White 3. If necessary, set up the generator for HDMI output. • See “Setting up the generator for HDMI operation” on page 147 for steps on setting up the generator for HDMI operation. 4. Using the Format knob, select an appropriate format for the connected HDMI display. 5. Using the Image knob, select any desired image. 6. Using a terminal emulator, establish a terminal connection with the generator. 7. Configure the generator to use an external audio source by entering the following command: SDMG 2 FMTU 8. Set the sample frequency to match the frequency of the external source by entering the following command: ARAT 44.1E3 (example only) Alternatively configure the generator to detect the audio sampling rate from the channel header of the incoming digital audio. ARAT 0.0 Note: The default frequency is 48 kHz (which is used by DVD players). However, if the external source is an audio CD played on a DVD player, the player will output S/PDIF with a sampling rate of 44.1 KHz (not 48 KHz). In this case, set the sampling frequency to 44.1 kHz (or reload the format, which will detect the sampling frequency automatically). 9. Turn on the external audio source. The external audio signal will be encoded into the HDMI signal. Note: The generator cannot independently control external source channels. You must use the device generating the audio signal to control the channels. 802BT/802R Video Test Generator User Guide 159 10. To verify proper HDMI audio handling, check the following on the HDMI display: 160 • Audio is output from the proper channels (left, right, or both). • When the volume is adjusted at the external source, the volume is subsequently changed. Chapter 9 Testing HDMI Sink Devices Testing HDMI InfoFrames This section provides steps on how to test handling of auxiliary (InfoFrame) packets by an HDMI display. The generator loads and sends default Auxiliary Video Information (XAVI), Audio (XAUD), and Source Product Description (XSPD) InfoFrame packet buffers to the display for each format (see table on page 149 for a listing of HDMI formats). The XAVI and the XAUD InfoFrame packets are sent at every frame (repeated mode), while the XSPD is sent only once. The XMPG and XGIF InfoFrames are gated off and not enabled. Viewing InfoFrame contents The 802 generator provides a convenient method for monitoring the InfoFrame content of the transmitted HDMI signal. To view current HDMI InfoFrame contents transmitted from the generator: 1. Connect an HDMI display to the Tx connector on the generator. 2. If necessary, set up the generator for HDMI output. • See “Setting up the generator for HDMI operation” on page 147 for steps on setting up the generator for HDMI operation. 3. Using the Format knob, select the HDMI format you want to test. 4. Using the Image knob, select the PacketTx image. The PacketTx image appears on the connected HDMI display. The image shows the current settings for the AVI InfoFrame output. 802BT/802R Video Test Generator User Guide 161 5. Press and release the Step key. The Step key illuminates. 6. Using the Image knob, select the appropriate InfoFrame type. The contents of the appropriate InfoFrame output appears on the HDMI display. 7. When finished, press and release the Step key. The light on the Step key extinguishes. Testing with Active Format Description (AFD) When transporting HDMI video images from a source to a display, different formats may be used between the content, transmission signal, and display. To provide compatibility between the different formats, Active Format Description (AFD) is used. AFD describes the portion of the coded video frame that is "of interest" (or “active”). The appropriate AFD information is transmitted with the video to the HDMI display as part of AVI InfoFrame packets. Using AFD information, the display is able to present the image optimally. For AFD testing, the generator allows you to apply different AFD cases using the AFDtest image, which provides 12 different cases (as image versions) for both 4:3 and 16:9 displays. As each image version appears, the appropriate AFD information is sent with the video to the display. The following table lists the AFD cases (as specified in the ETSI TR 101 154 v.1.4.1 standard) that are provided by the generator. 162 AFD case Image Version (4:3 Format) Image Version (16:9 Format) Aspect Ratio of Active Area 2 8 7 box 16:9 (top) 3 5 4 box 14:9 (top) 4 9-12 9-12 box > 16:9 (center) 8 0 6 Same as the signal format 9 1 1 4:3 (center) 10 7 8 16:9 (center) 11 4 3 14:9 (centered) 13 3 5 4:3 (with shoot and protect 14:9 center) 14 6 2 16:9 (with shoot and protect 14:9 center) 15 2 0 16:9 (with shoot and protect 4:3 center) Chapter 9 Testing HDMI Sink Devices To test an HDMI display’s ability to support AFD: 1. Connect an HDMI display to the Tx connector on the generator. 2. If necessary, set up the generator for HDMI output. See “Setting up the generator for HDMI operation” on page 147. 3. Using the Format knob, select an appropriate video signal format. See the table on page 149 for a listing of HDMI formats. 4. Using the Image knob, select the AFDtest image. The AFDtest image appears on the connected HDMI display (as shown below). 5. Press the Step key. The Step key illuminates, and the following image appears. 6. Using the Image knob, select an AFD scenario by selecting the appropriate image version number (1-12). Note: The image version number corresponds with the AFD case (or code). See the table on page 162 for a listing of the image numbers that correspond with each AFD case. 802BT/802R Video Test Generator User Guide 163 The image appears on the HDMI display. For example, the image representing AFD case 11 (image version 4) on a 4:3 display is shown in the example below. 7. Using the selected AFD scenario, verify that the HDMI display presents the image correctly. Note: Displays use the AFD information to determine how to present an image. Different displays may present HDMI video with the same AFD differently. 8. Using the Image knob, select additional AFD cases (as desired). 9. When finished, press and release the Step key. The light on the Step key extinguishes. 164 Chapter 9 Testing HDMI Sink Devices 10 Testing EDID Topics in this chapter: • Overview • EDID testing for source devices • EDID testing for sink devices 802BT/802R Video Test Generator User Guide 165 Overview This chapter provides procedures for testing EDID generation and handling. The generator can be configured to emulate an HDMI/DVI source when testing HDMI/DVI sink (display) devices or it can be configured to emulate an HDMI/DVI sink (display) device when testing an HDMI/DVI source device. Some of the EDID tests require the analyzer option. These include testing the EDID handling capabilities of a source device and the HDMI compliance EDID testing for a sink (display) device. Viewing EDID of a display and writing to a display is a generator function and does not require the analyzer option. 166 Chapter 10 Testing EDID EDID testing for source devices The generator can emulate an HDMI/DVI sink (display) in order to test HDMI source devices. Testing response of source to EDID The analyzer can emulate different HDMI/DVI displays using a built-in, configurable EDID structure. With this capability an HDMI/DVI source device can be tested for its ability to handle an EDID structure received from virtually any DDC-compatible display. You first have to configure the generator to support the HDMI/DVI signal source and enable measuring of internal signals. You then configure the EDID in accordance with a particular display. Use the following procedures. To set up the generator to perform HDMI/DVI testing: 1. Hold down the G and B keys, and then power on the generator. The following message appears on the front panel LCD. Special: keys Digital friendly 2. Release the G and B keys. The generator is placed in Digital Friendly mode. 3. Hold down the R and ACS keys, and then cycle the power to the generator. The following message appears on the front panel LCD. Special: keys hot-plug formats 4. Hold down the Step, G, and B keys while starting the genertor, until Status display appears on the LCD. 802BT/802R Video Test Generator User Guide 167 5. Release the Step, G, and B keys to enable status display on the generator (see example below). Color space Color depth Video type H31 V60 Format name D8C=DMT0659 0=SMPTE133 Image version Image name The format status on the LCD will indicate whether the unit is outputting HDMI or DVI signal protocol from the Tx connector. An “H” in the format status (H8C in the example above) indicates HDMI output; a “D” in the format status indicates DVI output. Note: With the compliant Hot-plug Formats mode active and a hot-plug detected, the generator automatically selects the appropriate TMDS output signal protocol (HDMI or DVI) for the attached display (via EDID read). To configure the analyzer for internal measurements: 1. Connect a digital display with the DVI or HDMI transmitter on the generator. 2. Select the Analzyer image. The Analyzer Setup Utility appears on the connected display. 3. Press and release the Step key. The Step key illuminates and the Analyzer Images field is highlighted. 168 Chapter 10 Testing EDID 4. Using the Image knob, select the ON setting to enable analyzer images. 5. Using the Format knob, select the Auto Based On field. 6. Using the Image knob, select CURRENT in the highlighted field to measure the HDMI/DVI signal originating internally from the generator. 7. Press and release the Step key to save the currently displayed parameters. The light on the Step key extinguishes, and the new settings are implemented for analyzer mode operation. To configure the analyzer to emulate the EDID structure of a display: 1. Determine the HDMI/DVI display you wish to emulate and if possible obtain a text file of its EDID. Note: This can be obtained from the manufacturer or by reading the EDID using the HDMI/DVI generator. For procedures on reading the EDID of a display with the generator, please refer to “Viewing EDID from a display” on page 171. 2. Connect an HDMI/DVI cable between the HDMI/DVI Tx and Rx connectors on the generator. 3. Using a terminal emulator, establish a terminal session with the generator (see page 14). 4. Modify the EDID structure in the generator using the XDID and DIDU commands. For example, to change the color characteristics of the EDID structure (a total of 10 bytes starting at byte 19), you could use the following command strings: XDID 19 A E88A82A0564796240F48 DIDU To program multiple segments (or the entire EDID structure) at once, create a text file containing the EDID. Then send the text file to the generator using your terminal emulator’s file transfer feature. The following commands write the entire EDID block 0: XDID 0 80 00FFFFFFFFFFFF005A63118F01010101130D010380221B782A4706A55C47 9C251E4F54BFEF008180310A010101010101010101010101302A009851002A40307013 00520E1100001E000000FF004132333033313931353335390A000000FD00324B1E530E 000A202020202020000000FC0056583730302D330A20202020200095 DIDU 5. To verify the EDID structure, use the EDID? query. This command will display the entire EDID structure in ASCII hex format. To view a specific segment of EDID, use the I2CR? query. This command will display the requested EDID in ASCII hex format. 6. If desired, use the STRG command to stretch the SCL low signal for 5 ms in the analyzer’s receiver. 802BT/802R Video Test Generator User Guide 169 To test the source device’s handling of the EDID: 1. Connect the HDMI/DVI source device to the HDMI/DVI Rx connector on the generator. Upon receiving the HDMI/DVI signal at the HDMI/DVI Rx connector, the generator sends the EDID structure to the source device. 2. At the HDMI/DVI source device, compare the processed EDID information with the EDID structure defined in the generator. 170 Chapter 10 Testing EDID EDID testing for sink devices The generator can emulate an HDMI, DVI or VGA source device in order to test HDMI, DVI or VGA displays. This includes viewing EDID from a display and writing EDID data to a display. The generator can test an HDMI display device’s EDID structure and transmission in accordance with the HDMI Compliance Test Specification 1.0. Viewing EDID from a display You can use the generator to view EDID from a DDC-compliant VGA, HDMI or DVI display connected with the generator. To view EDID information from an HDMI, DVI or VGA display: 1. Connect an HDMI, DVI or VGA device to the HDMI, DVI or VGA Tx connector on the generator. 2. Using the Format knob, select an appropriate format for the HDMI, DVI or VGA display connected to the HDMI, DVI or VGA Tx connector. Alternatively, to automatically configure the Format knob list based on the EDID of the display, hold down the R key, and then press and release the ACS key. 3. Using the Image knob, select the EdidData image. The EdidData image displays the first block of data. 4. Press the Step key, turn the Image knob to the first EDID block. 802BT/802R Video Test Generator User Guide 171 5. To view parsed EDID information, press and release the Step key, and then turn the Image knob to view additional blocks and parsed data. To query EDID information from an HDMI, DVI or VGA display via the command line: 1. Using a terminal emulator, establish a terminal session with the generator (see page 14). 2. To view the current EDID in ASCII hex format, use the EDID? command. To view a specific segment of EDID, use the I2CR? command. Querying the EDID from the command line enables you to create a text file with the EDID in order to configure the analyzer to emulate the display device. Writing EDID data to a display You can modify the EDID in the connected display, if the EEPROM in the display is writable. To modify the EDID in a display: 1. Connect the display to be modified to the HDMI, DVI or VGA Tx connector on the generator. 2. Using a terminal emulator, establish a terminal session with the generator (see page 14). 172 Chapter 10 Testing EDID 3. Use the I2CW command to modify the EDID structure in the connected display. For example, to change the color characteristics of the EDID structure (a total of 10 bytes starting at byte 19), you could use the following command string: i2cw eprom1 a0 25 A E88A82A0564796240F48 4. To program multiple segments or a complete EDID structure, use a text editor to enter the commands in a text file, and then download the file to the generator from a terminal emulator program such as HyperTerminal. Testing EDID in HDMI sink device for HDMI compliance The analyzer supports the following EDID and video HDMI compliance tests in accordance with the HDMI Compliance Test Specification 1.0 (CTS): • Test ID 8-1: EDID Readable • Test ID 8-2: EDID VESA Structure • Test ID 8-3: CEA Timing Extension Structure • Test ID 8-17: 861B Format Support Requirements • Test ID 8-18: HDMI Format Support Requirements • Test ID 8-19: Pixel Encoding Requirements • Test ID 8-20: Video Format Timing These tests are intended for in-house testing of products before submission to an HDMI ATC for full certification testing. Overview of HDMI compliance testing HDMI compliance testing is conducted through the generator’s transmit HDMI connector. A standard HDMI-to-HDMI cable is used between the device under test and the generator. The generator must be placed in the digital friendly mode and set to output HDMI signals, which is the default configuration for HDMI equipped generators. After making the physical connections you need to specify the capabilities of the sink display under test. This enables the generator to compare the expected results with the actual results measured from the display. Use the CDF_Sink image, which is based on the Capabilities Declaration Form (Appendix 3) of the Compliance Test Specification, to specify the display capabilities. To test the sink device, load the EdidHDMI image, and turn the image knob to advance through each test listed above in sequence. 802BT/802R Video Test Generator User Guide 173 Testing HDMI sink devices for EDID compliance The procedures for EDID and video testing of HDMI sink devices in accordance with the HDMI Compliance Test Specification 1.0 are provided below. Note: The EDID and video tests should be performed in sequence as a single test series. Each test is dependent on successful completion of the previous test. To set up the generator for HDMI compliance testing: 1. Hold down the G and B keys, and then power on the generator. The following message appears on the front panel LCD. Special: keys Digital friendly 2. Release the G and B keys. The generator is placed in Digital Friendly mode. 3. Select and apply a valid HDMI format such as DMT0660 either by turning the Format knob or entering the following command: FMTL DMT0660; FMTU 4. Load the GenOps image to verify that the generator is configured to output HDMI (that it is not in DVI-only mode). The generator’s default configuration is to output HDMI. Note that the display status mode will indicate that the generator is in HDMI mode with an “H” character. You can also verify that the generator is putting out an HDMI signal by issuing the following command: HDMI? The returned value should be 1 indicating HDMI output. 174 Chapter 10 Testing EDID To specify the capabilities of the sink device: 1. Load the CDF_Sink image, which is shown below. 2. Press and release the Step key to enable selection of each field. Use the Format knob to position the cursor. Use the Image knob to choose values. For example, if your display supports both 4:3 and 16:9 aspect ratios, set the Sink_PrimaryAR field to Both. 3. Press the Step (Exit) key to save the settings. The settings are stored until you change them, and are kept if the generator is restarted. To initiate the compliance testing: 1. Load the EdidHDMI image. 2. Press and release the STEP key, then turn the Image knob to progress through the tests in the sequence below. 802BT/802R Video Test Generator User Guide 175 Testing EDID readability (Test ID 8-1) - This test verifies that the EDID can be read properly. The screens are shown below. ( 176 Chapter 10 Testing EDID Testing EDID VESA structure (Test ID 8-2) - This test verifies that the data in the base EDID 1.3 block and basic EDID Extension handling is correct and meets all aspects of the relevant specifications. 802BT/802R Video Test Generator User Guide 177 Testing CEA timing extension structure (Test ID 8-3) - This test verifies that the data in any CEA Timing Extension present in EDID is formatted properly and meets all aspects of the relevant specifications. 178 Chapter 10 Testing EDID Testing 861B Format Support Requirements (Test ID 8-17) - This test verifies that no 861B-defined video format is declared only in a Detailed Timing Descriptor. 802BT/802R Video Test Generator User Guide 179 Testing HDMI Format Support Requirements (Test ID 8-18) - This test verifies that Sink DUT indicates support for all required video formats in its EDID. 180 Chapter 10 Testing EDID Testing Pixel Encoding Requirements (Test ID 8-19) - Verifies that the Sink supports YCpCr pixel encoding when required. To create a knob list of all formats supported by the display: 1. Press and release the STEP key to return to the initial compliance testing screen. The STEP key should be extinguished. 802BT/802R Video Test Generator User Guide 181 2. Press and hold the R key and then press and release the ACS key. Alternatively power off the generator, press and hold both the R and ACS keys then power up the generator to configure the generator knob list with the hot plug formats. The initial compliance test screen re-appears and the Format knob list includes only those formats in the display EDID. Visual verification of formats Additional visual inspection of Tests 8-19 and 8-20 is necessary to ensure that each format can be loaded and displayed at each pixel encoding and at its minimum and maximum pixel rate. Test ID 8-19 involves testing each format with different YCbCr pixel encoding: 4:4:4 pixel sampling and 4:2:2 sampling. Test ID 8-20 requires that each format listed in the EDID be be tested at two different pixel clock frequencies. The two different frequencies shall be the minimum and maximum permitted by a Source. For 50Hz formats, these values are 49.75Hz and 50.25Hz (50Hz ± 0.5%). For 59.94Hz or 60Hz formats, these frequencies are 59.64Hz (59.94Hz – 0.5%) and 60.3Hz (60Hz + 0.5%). The tested pixel clock frequency accuracy shall be ±0.05%. A separate listing of the formats is provided on the Format knob list to support this visual inspection testing. The nomenclature for visual inspection testing of maximum and minimum pixel rate is of the form shown in the example below: 182 Chapter 10 Testing EDID Example SVD 01 Y2 1 Short Video Descriptor VIC Component color sampling Format Index • SVD – Short Video Descriptor. • 01 – EIA/CEA-861-B Format Video Identification Code (for example 01, 02, 06, etc. listed on page 149) • Y2 – Y indicates color difference. 2 = 4:2:2 pixel sample encoding. 4 = 4:4:4. • 1 – Represents DMT0659 format, which is first format (index 1) listed under video identification code 01 in table on page 149. The nomenclature for visual inspection testing for pixel encoding is of the form shown in the example below: SVD 01 H 01 Short Video Descriptor VIC Frequency (High / Low) Format Index • SVD – Short Video Descriptor. • 01 – EIA/CEA-861-B Format Video Identification Code (for example 01, 02, 06, etc. listed on page 149) • H – Indicates that format is using maximum (H = High) or minimum (L = Low) frequency required by compliance test. • 01 – Index of format as listed under video identification code onpage 149. To visually validate the formats in the knob list for pixel encodings and pixel rate: 1. Select an image suitable for testing the display type by turning the Image knob or entering the appropriate command. For example to display the Master image enter: IMGL Master; IMGU 2. Turn the format knob to display each of the formats in the knob list that begin with SVD. Each format should display properly. 3. Turn the format knob to display each of the formats in the knob list. Each format should display properly. 802BT/802R Video Test Generator User Guide 183 184 Chapter 10 Testing EDID 11 Testing HDCP You can use the generator, with the High-bandwidth Digital Content Protection (HDCP) option installed, to test HDCP 1.0 and 1.1 compliant devices. For more information about HDCP, see http://www.digital-cp.com/. Topics in this chapter: • Testing DVI or HDMI receiver with HDCP • Testing HDCP between HDMI transmitter and DVI receiver • Testing HDCP with static images • Using command-line interface to control HDCP • Troubleshooting HDCP errors 802BT/802R Video Test Generator User Guide 185 Testing DVI or HDMI receiver with HDCP This section describes how to test DVI and HDMI receivers with HDCP. All DVI and HDMI options, including analyzer options, support HDCP production keys if the HDCP option is installed. Some DVI options support both production and public keys. To determine which HDCP keys your generator supports: 1. Load the GenStats image. 2. Verify that HDCP is listed under the Options heading, which indicates that the HDCP option is installed, and that production keys are available. 3. If the following image names are listed on the LCD, then HDCP public (test) keys are installed. • HdcpA1B1 • HdcpA1B2 • HdcpA2B1 • HdcpA2B2 Note: With older firmware installed, you may be able to select these images, but an “Image is not available” message is displayed on the display connected with the generator. This message indicates that public keys are not installed. To test HDCP with a DVI device: 1. Hold down the G and B key while starting the generator put the generator in digital friendly mode. Alternatively, enter the following command: SROP 2 2. Connect the DVI transmitter on the generator to the device’s DVI receiver. 3. Select an appropriate HDCP test image. If you are testing a device with a production key, select the HdcpProd(uction) image. The HdcpProd image assumes that both the HDCP transmitter and receiver have a production key. If your generator supports public keys, select the appropriate image below. For example, if the receiver has pubic key B2, and you want to use public key A1 in the transmitter, then select the HdcpA1B2 image. 186 • HdcpA1B1 • HdcpA1B2 • HdcpA2B1 Chapter 11 Testing HDCP • HdcpA2B The image will indicate if the test passed or failed. If the test fails, see “Troubleshooting HDCP errors” on page 191. 4. To test another device, connect the cable to the new device. The HDCP test starts automatically. To test HDCP with an HDMI device: 1. Hold down the G and B key while starting the generator put the generator in digital friendly mode. Alternatively, enter the following command: SROP 2 2. Connect the HDMI transmitter on the generator to the device’s HDMI receiver. 3. Select the HdcpProd(uction) image. The image will indicate if the test passed or failed. If the test fails, see “Troubleshooting HDCP errors” on page 191. 802BT/802R Video Test Generator User Guide 187 Testing HDCP between HDMI transmitter and DVI receiver HDCP 1.1-compliant devices must interoperate with HDCP 1.0 compliant devices using the DVI protocol. Generators with an HDMI transmitter can be used to test HDCP with devices that have an DVI receiver. To test HDMI Tx with DVI Rx: 1. Hold down the G and B key while starting the generator put the generator in digital friendly mode. Alternatively, enter the following command: SROP 2 2. Establish a command terminal connection with the generator, using HyperTerminal or VGM. 3. At the R:> prompt, enter the following to set the HDMI transmitter into DVI mode, which disables audio: HDMI 0 ALLU The DVI mode setting is saved until you change it. 4. Use an HDMI-to-DVI cable (provided with HDMI generator) to connect the HDMI transmitter to the DVI receiver. 5. Load the HdcpProd image. This image assumes that both the transmitter and receiver are using production keys. The image will indicate if the test passed or failed. If the test fails, see “Troubleshooting HDCP errors” on page 191. To change HDMI transmitter from DVI to HDMI mode: 1. Establish a command terminal connection with the generator, using HyperTerminal or VGM. 2. At the R:> prompt enter the following to invoke the HDMI mode: HDMI 1 ALLU 188 Chapter 11 Testing HDCP Testing HDCP with static images The standard HDCP test images have color bars in the background. A special mode is available for testing HDCP with any static background image you specify. To test HDCP with a different background image: 1. Turn on the generator while holding down the G and ACS keys until hdcp tester is displayed. Alternatively, enter the following command: SROP 8192 2. Select a format that is supported by the display, and then load any static image. The HDCP test begins automatically when you connect the display. If the HDCP test passed, the generator displays the image you specified. If the test failed, the display will remain blank. See “Troubleshooting HDCP errors” on page 191. 802BT/802R Video Test Generator User Guide 189 Using command-line interface to control HDCP The command interface can control HDCP tests in automated testing environments. To run HDCP test from command prompt: 1. Establish a command terminal connection with the generator using VGM or HyperTerminal. 2. Connect the device to be tested to the transmitter on the generator. 3. At the R:> prompt, enter the following command to run the HDCP test: HDCP? HDCP? command The HDCP? command is the only command used to control HDCP tests. Syntax HDCP? [ A1 | A2 ] [ B1 | B2 ] [frames] Where frames is the number of frames to be tested. The default number of frames is 512. Example Error codes 190 These examples demonstrate how to specify which test to run. Command Result hdcp? Runs test with production keys for 512 (default) frames, and then returns 0 if the test passed, or an error number if the test failed. hdcp? 2000 Run test with production keys for 2000 frames. hdcp? a1 b1 Runs test with public keys A1 and B1 for 512 frames. hdcp? a2 b1 2000 Runs test with public keys A2 and B1 for 2000 frames. These errors may occur when using the HDCP? command. Code Meaning 9520 HDCP key combination is not supported. Valid combinations are A1/B1, A2/B1, A1/B2, and A1/B2. 9521 Test started successfully, but failed during test. 9522 Test did not start. 9508 Specified keys are not present. Chapter 11 Testing HDCP Troubleshooting HDCP errors Common problems This table describes possible solutions to problems that may occur during HDCP testing. Problem Solution Test fails at step 3 Transmitter could not read Bksv from the receiver, Bksv was read correctly but is a wrong value, or an I2C error occurred. If the EdidData image loads, the I2C communication is working properly. Verify that the Bksv value is 5 bytes (that is, 40 bits of which 20 zeros and 20 ones) by reading the value from the test image. HdcpProd image flashes repeatedly at step 9 Restart the generator while holding down the Outputs key, or use the SROP 16 command, which starts the generator in “Reset HDCP Rx by gating clock” mode. HdcpProd image is unavailable The HdcpProd image requires the HDCP production key option to be installed in the generator. To determine if this option is installed, view the GenStats image. The HDCP option will be listed under the Options heading if it is present. Running HDCP test in step mode The generator normally runs the steps in the HDCP test automatically. If the test fails, the test is restarted after a few seconds, which makes it difficult to read values at the step where the test failed. Run any HDCP test in manual mode to pause the test after each step. To run the HDCP test in step mode: 1. At any step during an HDCP test, press the Step key. 2. Turn the Image knob to advance to the next step. If you are using an PCI-based generator, use the commands displayed on the screen to advance to the next step. 3. Press the Step key again to return to automatic mode. Running an HDCP self-test An HDCP self-test checks that HDCP authentication is working properly between the transmitter and receiver on the analyzer. This test can also be used to confirm that a cable is not interfering with HDCP authentication, and that the DDC clock and DDC data pins, which the I2C buss uses, are working correctly. 802BT/802R Video Test Generator User Guide 191 To run an HDCP self-test: 1. Hold down the G and B key while starting the generator put the generator in digital friendly mode. Alternatively, enter the following command: SROP 2 2. Connect your cable to the Rx and Tx on the analyzer. 3. Select the HdcpProd image. When testing a display, the HDCP test results are displayed on the display being tested. When testing a cable, where no display is connected to the transmitter, test results are displayed by the LCD display on the generator. If HDCP authentication is working correctly, the name of the HdcpProd image on the LCD will be updated with Ri values every 2 seconds. If HDCP is not working, the LDC display will remain static. Understanding the HDCP test Understanding what the generator does during an HDCP test can help you determine why an HDCP test failed. To determine which hardware is installed: 1. Load the GenStats image. 2. Compare the following table with the GenStats image to determine which hardware is installed. GenStats information Hardware DVI (SiI) (under Options) and DVI FPGA less than F1 (under Generator Information) Silicon Image DVI (under Options) Broadcom DVI Analyzer (under Options) Silicon Image DVI II (under Options) and DVI FPGA F1 or later (under Generator Information) Silicon Image DVI II (under Options) and DVI FPGA is earlier than F1 (under Generator Information) Broadcom HDMI (under Options) Silicon Image HDMI Analyzer (under Options) Silicon Image Test sequence for Broadcom transmitters: 1. The generator resets the transmitter and its HDCP engine. 192 Chapter 11 Testing HDCP 2. If the “Reset HDCP Rx by gating clock” mode is enabled, the generator resets the receiver, and gates off transmitter clock and data for 400 mS. Otherwise, the receiver is not reset. 3. The transmitter reads the Bksv (HDCP receiver KSV), over the I2C bus, and verifies that it has 20 zeros and 20 ones. This step is the first interaction between the transmitter and receiver. 4. Receiver writes the receiver KSV to the transmitter. 5. Transmitter generates An (session random number). 6. Transmitter writes An to the receiver, using the I2C bus. 7. Transmitter writes the transmitter KSV to the receiver, using the I2C bus. 8. Load the transmitter keys. 9. The transmitter reads the Ri value (link verification response) from the receiver and compares it with its own generated Ri value. They should match to proceed. If this step fails, the test returns to step 1. 10. Generate authentication. 11. Transmitting encrypted data. Test sequence for Silicon Image transmitters: 1. Reset the transmitter. 2. If the “Reset HDCP Rx by gating clock” mode is enabled, the generator initializes the transmitter. Otherwise, do not initialize the transmitter. 3. Transmitter generates An (session random number). 4. Transmitter writes An to the receiver, using the I2C bus. This step is the first interaction between the transmitter and receiver. The transmitter reads the Bksv, over the I2C bus, and verifies that it has 20 zeros and 20 ones. 5. Write the transmitter KSV to the receiver. 6. Read and verify the receiver KSV. 7. Write receiver KSV to transmitter. 8. Ri ready at transmitter. 9. The transmitter reads the Ri value from the receiver and compares it with its own generated Ri value. They should match to proceed. If this step fails, the test returns to step 1. 10. Generate authentication. 11. Transmitting encrypted data. 802BT/802R Video Test Generator User Guide 193 194 Chapter 11 Testing HDCP 12 Using Special Sync Output Topics in this chapter: • Operating special sync for probe pulse • Configuring special sync for FS, LS or CS 802BT/802R Video Test Generator User Guide 195 Overview The generator is equipped with a Special Sync BNC connector labeled S/S on the front right side. You can configure the output of this video interface to output frame sync, line sync, composite sync or a special probe pulse. 196 Chapter 12 Using Special Sync Output Operating special sync for probe pulse The probe feature is used in connection with a programmable probe pulse that is available on the S/S BNC. This pulse is most often used to trigger an oscilloscope or synchronize an inspection camera. The probe feature allows you to position the leading edge of the probe pulse anywhere within the video frame. This feature greatly facilitates troubleshooting by enabling you to focus on specific video signal problems occurring anywhere in the video signal. Configuring the probe feature involves positioning the probe pulse in the desired location on the video frame. You can do this either through the front panel or the command line interface. The front panel display is most convenient if you are near the generator and not using a computer or terminal. You can control the generator through the command line interface either locally or remotely through the serial connection. Front panel controls and indicators To use the probe feature begin by first activating the probe feature through the generator keys, and then positioning the pulse in the desired location by turning the Format knob (horizontal position) and the Image knob (vertical position). The current position of the pulse is shown on the LCD. Probe coordinate numbering Unlike ITU and SMPTE standards, Quantum Data standards count pixels, lines, and coordinates beginning with the number zero (not one) to improve the mapping between video signal specifications and modern computer graphics coordinates. The television standards are accounted for by suppressing any half-active line that appears in an equalizing interval and lengthening (to a full line) any half-active line that begins in the active portion of a field. Vertical counting always begins with the leading edge of blanking of the first field (not vertical sync). The first field is always defined as the field that includes the top line of the displayed picture (Y:0). This definition is always true whether the total number of active lines is odd or even. With interlaced scanning, lines continue to be numbered sequentially throughout the frame, beginning with the leading edge of blanking of the first field. Therefore, the first two lines of blanking in the first field are numbered L:0 followed by L:1. If you have 525 total lines and 486 of those are active, for example, the first two (blank) lines of the second field would be numbered L:262 and L:263. The Y position continues to follow the visual order of lines going from the top to the bottom of the screen. If the last line of blanking in the first field is L:18, then L:19 corresponds to Y:0, L:20 to Y:2, L:21 to Y:4 and so on. In the second field, L:282 would correspond to Y:1, L:283 to Y:3, L:284 to Y:5 and so on. 802BT/802R Video Test Generator User Guide 197 Configuring the probe feature This section describes how to configure the probe feature. To enable the probe feature: 1. Deactivate the signal outputs of the generator by pressing the Outputs key. The light on the Outputs key extinguishes. 2. Hold down the Step key, and then press and release the Outputs key. The LCD displays a Probe feature message, and then the following screen. 3. Release the Step key. Setting sensitivity of knobs You can control the amount of distance traveled with each click of the Format and Image knobs by using the ACS, DCS, and DSS keys. If neither ACS, DCS, nor DSS is selected, then the amount of movement is increased exponentially as you move farther in a particular direction and is reset when you change direction. To set the sensitivity of the Format and Image knobs: 1. Press the appropriate key: Sensitivity Procedure 100 pixels/lines per knob click Press the ACS key. The key illuminates. 10 pixels/lines per knob click Press the DCS key. The key illuminates. 1 pixel/line per knob click Press the DSS key. The key illuminates. Controlling probe using generator controls This section procedures for controlling the special sync probe through the front panel keys and knobs. To position the probe pulse in a specific location in the video signal: 1. Turn the Format knob to set the horizontal position of the probe pulse to the desired pixel relative to the leading edge of the horizontal sync. The horizontal position of the probe is simultaneously displayed in two different ways: 198 • The horizontal position P:nnnn is given in pixels relative to the leading edge of the horizontal sync. • If the leading edge of the probe is within the active portion of a line, an alternate horizontal position X:nnnn is also displayed, indicating the number of pixels Chapter 12 Using Special Sync Output between the start of active video (X:0) and the leading edge of the probe pulse in the horizontal direction. 2. Set the vertical position by turning the Image knob. The vertical position of the probe is simultaneously displayed in two different ways: • The vertical position L:nnnn is given in whole scan lines relative to the leading edge of blanking of the frame or first field. • If the probe is within the active portion of the frame, an alternate vertical position Y:nnnn is also displayed, indicating the number of lines between the start of active (Y:0) and the leading edge of the probe in the vertical direction. To position and activate the probe pulse: 1. Press the Step key. The cursor appears. You may have to turn the Format and Image knobs to move the cursor into the active video. This feature allows you to visually move the probe to an area of interest (within the active portion of the frame) without using numerical coordinates. 2. Turn the Format knob to move the cursor horizontally. Turn the Image knob to move the cursor vertically. 3. Activate the probe pulse. Action Procedure Activate the probe pulse on the specified Press the R and G keys. The light on the scan line keys extinguish. Activate the probe pulse on all active scan Press the R key. The light on the key lines at the same horizontal position illuminates. Activate the probe pulse on all scan lines, Press the G key. The light on the key whether active or not at the same illuminates. horizontal position Controlling probe using command line interface Using the command line interface to control the probe provides more control, enables you to change the polarity and width, and to change the format and image while maintaining the probe pulse parameters. To configure the probe feature: 1. Enable the probe feature by entering the following commands: FSPG PSPG PSPP PSPW 0 1 1 10 // // // // 802BT/802R Video Test Generator User Guide disable the frame sync on special sync output enable the probe pulse Set the probe pulse polarity (0 for low or 1 for high) set pulse width to 10 pixels (range: 1 pixel to HTOT - 1) 199 PSHD edge PSVD edge ALLU 100 // set pulse horizontal position at 100 pixels from leading of horiztonal sync pulse, in range from 0 <= PSHD<(HTOT - PSPW - 1) 50 // set the pulse vertical position at 50 lines from leadinig of vertical blanking, in range from 0<=PSVD<(VTOT-1) // apply the settings To set the lines on which the probe pulse occurs: 1. Send the appropriate command: Set the probe pulse to occur Command Once per frame PSPM 0 Once every active line PSPM 1 Once every line PSPM 3 2. Send the ALLU command to apply the setting. 200 Chapter 12 Using Special Sync Output Configuring special sync for FS, LS or CS The special sync output can provide frame sync, line sync, or composite sync signals. The output is controlled by setting parameters of these signals through the command line interface. The following commands are used to set the special sync signal: • FSPG - Frame sync • PSPG - Probe signal • LSPG - Line sync • CSPG - Composite sync Note: The special sync output is disabled whenever these parameters are set to zero. A frame pulse can be generated and output at the beginning of each frame. In the case of interlaced video, the frame pulse is output at the beginning of the blanking interval (of the first field) that immediately precedes the top line of active video. Field 0 Blank Field 1 Active Blank Active VID VSPD (lines) VS FSPD (lines) FS FSPG=1, FSPP=1 FSPW (pixels) FS FSPG=1, FSPP=0 To configure frame sync on the special sync output: 1. Enable the frame sync by entering the following command: FSPG 1 The values of the other parameters (LSPG and CSPG) do not matter once FSPG is enabled. 2. Set the frame pulse polarity (either 0 for low or 1 for high) by entering the following command: FSPP 1 802BT/802R Video Test Generator User Guide 201 3. Set the frame pulse pixel width (in the range from 1 pixel to HTOT - 1) by entering the following command: FSPW 100 4. Set the frame pulse delay (in the range from 0 <= FSPD < (VTOT - FSPW - 1) [default = 0]) by entering the following command: FSPD 10 5. Save these settings by entering the following command: ALLU To configure line sync on the special sync output: 1. Enable the line sync signal by entering the following commands: FSPG 0 PSPG 0 LSPG 1 ALLU The value of composite sync CSPG does not matter once these are set. 2. Set the line sync pulse polarity by entering the following command: LSPP 1 ALLU // 1 = high (default) To configure composite sync on the special sync output: 1. Enable digital composite sync by entering the following command: SSST 2 (or 6,11) Alternatively, you can press the DCS key on the front panel. 2. Enable the composite sync signal by entering the following commands: FSPG PSPG LSPG CSPG ALLU 0 0 0 1 3. Set the composite sync pulse polarity by entering the following commands: CSPP 1 ALLU 202 // 1 = high (default) Chapter 12 Using Special Sync Output A Command Reference Topics in this appendix: • Commands by name Video Test Generator User Guide 203 Commands by name 204 Appendix A Command Reference *CLS Clear Status Class Description Command syntax Related commands GPIB Clears the Event Status Register, the Status Byte and the output buffer. *CLS *ESR?, *STB Video Test Generator User Guide 205 *DDT Delay Device Trigger Class Description Command syntax Example Related commands 206 Trigger Specifies a command or command string to be executed when the generator is “triggered” with the *TRG command. Only one *DDT command can be pending at a time. The command or query arguments must be enclosed in quotes. *DDT “command_1; command_2 ... command_n” *DDT “imgl flat; imgu” *TRG // to invoke the command line in quotes from the *DDT command *TRG Appendix A Command Reference *ESE Event Status Enable Class Description GPIB Sets the Event Status Enable register to the given mask value. The bits in the Event Status Enable register function as enable bits for each corresponding bit in the Event Status register. That is, when a bit in the Event Status register goes high, and the corresponding bit in the Event Status Enable register is a 1, it is enabled and will cause the ESB bit in the Status Byte register to go high. The *ESE? query returns the current value of the Event Status Enable register. Command syntax *ESE mask mask 0 - 255 Example *ESE 8 Query syntax *ESE? Query response mask NL Where mask is in integer NR1 form. See also: *CLS, *ESR? Video Test Generator User Guide 207 *ESR? Event Status Register Class Description Query syntax Returns GPIB Returns the current value of the Event Status register. After this command is executed, the Event Status register is cleared. This is the only way of clearing any bit in the Event Status register except by the *CLS command. *ESR? registerValue NL Where registerValue is in integer NR1 form. Related commands 208 *CLS, *ESE Appendix A Command Reference *IDN? IDeNtification Class Description Query syntax Returns GPIB Returns an equipment identification string formatted per IEEE-488.2 standards. *IDN? Company,Model,SerialNumber,FirmwareVersion Company Always QuantumData. Model Product model description. SerialNumber Serial number of nonvolatile SRAM module (Dallas chip) in generator. FirmwareVersion Version number of currently installed firmware. Example R:\*idn? QuantumData,802BT-DVI-AN,7514191,7.38380000 Video Test Generator User Guide 209 *OPC OPeration Complete Class Description GPIB Causes the 882 to set the OPC bit in the Event Status register when all operations have been completed. Since there are no overlapping commands, the *OPC command will set the OPC bit immediately when executed. The *OPC query will put a 1 in the output buffer when all operations are complete. Command syntax Query syntax Returns 210 *OPC *OPC? NL Appendix A Command Reference *RST ReSet Class Description GPIB Performs a device reset. This places the 882 into a known condition. These conditions are: • IEEE-488 address set to 15 • Status Byte cleared • Input queue empty • Output queue empty Command syntax *RST Related commands *CLS Video Test Generator User Guide 211 *SRE Service Request Enable Class Description Command syntax GPIB Sets the Service Request Enable register to the mask value given. The bits in the Service Request Enable register function as enable bits for each corresponding bit in the Status Byte register to enable a condition to request service from the system controller. That is, when a bit in the Status Byte register goes true, and the corresponding bit in the Service Request Enable register is also true, the 882 will request service through the GPIB. The *SRE query returns the current value of the Service Request Enable register. *SRE mask mask 0 - 255 Example Query syntax Returns *SRE 16 *SRE? mask NL Where mask is in integer NR1 form. Related commands 212 *STB, *ESE Appendix A Command Reference *STB STatus Byte Class Description Query syntax Returns GPIB Returns the current value of the Status Byte register. The value stored in the Status Byte register is not affected by reading it. *STB? statusByte Where statusByte is in integer NR1 form. Related commands *SRE, *ESR?, *CLS Video Test Generator User Guide 213 *TRG TRiGger Class Description Command syntax Example Related commands 214 GPIB port control Triggers the generator programmatically. The *TRG command is used to trigger a command or command string entered with the *TRG command. *TRG *DDT “imgl flat;imgu” *TRG // Invoke the command line in quotes from the *DDT command *DDT Appendix A Command Reference *TST self TeST Class Definition: Query syntax Returns GPIB port control Causes the 882 to perform a self-test and report the results in a response message. If the self-test fails, an ASCII "1" is placed in the output buffer; otherwise, an ASCII "0" is placed in the output buffer. *TST? result Where result is in integer NR1 form. Video Test Generator User Guide 215 *WAI WAIt for completion suffix Class Description Command syntax GPIB port control Causes the generator to wait until all processes have been completed before sending the prompt. Normally, the generator returns a prompt immediately after either an FMTU, IMGU, ALLU, BOOT, INIT, or SCAL command is received, even before these commands have finished executing. If the system controlling the generator must know when a command has finished executing, use a semicolon to append the suffix … ;*WAI. . command; *WAI command FMTU, IMGU, ALLU, BOOT, INIT, or SCAL Example 216 FMTL vga_m3 IMGL SMPTE133 ALLU; *WAI Appendix A Command Reference // // // // Load a format from memory to buffer Load the SMPTE RP-133 image to buffer Update hardware to current buffer contents and delay prompt until all done ADDR memory ADDRess Class Description Direct processor control Sets the pointer register that is used in connection with the PUTR command and GETR? query. The ADDR? query returns the current contents of the pointer register. Note: This command is used only with custom applications and command files created by Quantum Data. Command syntax ADDR address address 0 to 4,294,967,295 (BASE = 10) -2,147,483,648 to 2,147,483,647 (BASE = -10) to FFFFFFFF (BASE = 16) -80000000 to 7FFFFFFF (BASE = -16) Query syntax ADDR? Query response address Other required commands ADDR and ADDR? expect and return parameters formatted according to the current radix set by the BASE command. Video Test Generator User Guide 217 ADOT draw A single pixel DOT Class Description Command syntax Custom image primitive Draws a single pixel dot. A dot is the smallest graphic element that can be drawn. It uses three parameters: the color and the X and Y coordinates. ADOT color x y color available colors x positive integer number y positive integer number Other required commands Example 218 The FMTU command instructs the generator to use the new setting. The ALLU command updates hardware to the new setting and redraws the test image. ADOT White 200 300 ALLU Appendix A Command Reference // Draw white dot at X = 200 Y = 300 // Update hardware to current buffer contents ALIK ALIas Kill Class Description Command syntax Example Related commands Alias Removes an existing alias name. ALIK alias ALIK MYDMTFMT // removes alias format name MYDMTFMT ALIQ? to query alias names. ALIN to create an alias name. Video Test Generator User Guide 219 ALIN create ALIas New Class Description Command syntax Example Related commands Alias Creates an alias for an object such as a format, image or test sequence. You can create more than one alias name for an object. ALIN alias object ALIN MYDMTFMT DMT0675 // creates alias format for format DMT0675 Use ALIQ? to query alias names. Use ALIK to remove an alias name. 220 Appendix A Command Reference ALIQ? ALIas Query Class Alias Description Lists alias names. Query syntax ALIQ? start count Example Related commands ALIQ? 1 20 // show alias names from first alias name through 20th alias ALIK to remove an alias name. ALIN to create an alias name. Video Test Generator User Guide 221 ALLE end ALL Editor sessions Class Description Command syntax 222 Directory, format, image and sequence editor control Same as entering all of the DIRE, FMTE, IMGE and SEQE commands. ALLE Appendix A Command Reference ALLU ALL Use Class Description Command syntax Other required commands Example System control Checks the current contents of the format buffer for errors. If no errors are found, it reconfigures the signal generating hardware in accordance with the contents. Next, the current test image is re-rendered using the latest system and format parameter data. ALLU This command updates the generator after using the FMTL, IMGL and SEQL commands to load new files from memory. This command also can be used to see the results of work when using commands to edit formats or custom images. FMTL vga_m3 ALLU Video Test Generator User Guide // Load a format from memory to buffer // Update hardware to current buffer contents 223 AMAP render A pixel MAP Class Description Command syntax Bitmap image control Renders (copies) a pixel map stored in the generator as name to the frame buffer. The bitmap will be placed so that the top left corner will be at the given x, y location in the frame buffer. AMAP x y name x, y location name a valid MS-DOS filename (8 characters minus any extension) Query syntax Example 224 AMAP? AMAP 0 0 myicon Appendix A Command Reference // Renders a pixel map called “myicon” // in the top left corner of active video ANIG ANalyzer Image Gate Class Description Command syntax DVI signal analyzer Activates or deactivates the FormatRx and DeltaErr analyzer images. ANIG gate gate 0 = analyzer images are not activated 1 = analyzer images are activated Query syntax Query response Example ANIG? 0 or 1 ANIG 1 // activates analyzer images IMGL FormatRx; IMGU //outputs FormatRx image Video Test Generator User Guide 225 ANIM? current test image has ANIMation Class Description Query syntax Query response Image editor control Returns a flag indicating if the image currently being displayed is animated. ANIM? imageName 0 = Not animated (static image) or the image was not found. 1 = Animated. Example 226 ANIM? cubes 1 Appendix A Command Reference // to determine if the “cubes” image has animation // response indicates that “cubes” is an animated image ANTI ANTI-alias Class Description Command syntax Other required commands Image drawing primitives Causes other primitives to be drawn using anti-aliasing on diagonal edges when appearing anywhere in a custom image. This command affects only television formats on 801GX generators. It causes the leading and trailing edges of rectangles to have controlled rise and fall times. ANTI The IMGU or ALLU command must be used to redraw the custom image using anti-aliased primitives. Video Test Generator User Guide 227 ARAT Audio sampling RATe Class Description Command syntax Format parameter setting - Audio signal Sets the sampling rate of the audio stream output from the generator. This sets the CT parameter of the Audio InfoFrame (as specified in EIA/CEA-861-B, table 20). ARAT rate rate 192.0E3 176.4E3 96.0E3 88.2E3 48.0E3 (default) 44.1E3 32.0E3 Example Related commands 228 ARAT 48.0E3 IFGU XAUD (SF parameter) Appendix A Command Reference AROW render A ROW of pixels Class Description Command syntax Query syntax Example Bitmap image control Renders (copies) binary stored as a hexstring to the frame buffer. The bitmap will be placed so that the top left corner will be at the given x, y location in the frame buffer. AROW x y bpp hexstring AROW? AROW 5 5 4 02D Video Test Generator User Guide // render hex data “02D” directly into frame // buffer at location 5, 5 at a depth of // 4 bits-per-pixel 229 ASBG Analog Sync on Blue Gating Class Description Format parameter setting - Analog video signal Enables and disables adding composite sync to the blue analog video outputs when analog sync is selected (see SSST command) and an analog video signal is being generated (see AVST command). The ASBG? query returns the current setting of ASBG. See the ASSG command description for information on simultaneously controlling red, green and blue sync gating. Command syntax ASBG mode mode 0 = OFF 1 = ON Query syntax Query response Other required commands Example 230 ASBG? mode The FMTU command instructs the generator to use the new setting. The ALLU command updates hardware to the new setting and redraws the test image. ASBG 1 FMTU // Enable comp sync on blue in buffer // Update hardware to current buffer contents Appendix A Command Reference ASCT Analog Sync Composite Type Class Description Command syntax Format parameter setting - Analog video signal Sets the kind of composite sync added to the analog video outputs when analog sync is enabled (see SSST command) and an analog video signal is being generated (see AVST command). The ASCT? query returns the current setting of ASCT. A setting of zero (0) indicates that the ACS sync selection cannot be activated by the operator. ASCT type type 0 = none 1 = American HDTV ORed 2 = American ORed 3 = American w/serr 4 = American w/serr & eq 5 = European HDTV ORed 6 = European ORed 7 = European w/serr 8 = European w/serr & eq 9 = American HDTV w/serr 10 = American HDTV w/serr & eq 11 = European HDTV w/serr 12 = European HDTV w/serr & eq 13 = Japanese HDTV ORed 14 = Japanese HDTV w/serr 15 = Japanese HDTV w/serr & eq Query syntax Query response ASCT? type Video Test Generator User Guide 231 Other required commands Example 232 The SSST mode must be set to 4, 5, 6, or 7 and the AVST type must be set to 1, 2 or 5 in order for the ASCT setting to have any affect on the generator's hardware outputs. The FMTU command instructs the generator to use the new setting. The ALLU command updates hardware to the new setting and redraws the test image. ASCT 2 SSST 4 AVST 2 FMTU // // // // Enable Enable Select Update Appendix A Command Reference Amer ORed comp sync in buffer ACS analog RGB as video type hardware to current buffer contents ASGG Analog Sync on Green Gating Class Description (Obsolete) Format parameter Enables and disables adding composite sync to the green analog video outputs when analog sync is selected (see SSST command) and an analog video signal is being generated (see AVST command). The ASGG? query returns the current setting of ASGG. See the ASSG command description for information on simultaneously controlling red, green and green sync gating. Command syntax ASGG mode mode 0 = OFF 1 = ON Query syntax Query response Other required commands Example ASGG? mode The FMTU command instructs the generator to use the new setting. The ALLU command updates hardware to the new setting and redraws the test image. ASGG 1 FMTU Video Test Generator User Guide // Enable comp sync on green in buffer // Update hardware to current buffer contents 233 ASRG Analog Sync on Red Gating Class Description (Obsolete) Format parameter Enables and disables adding composite sync to the red analog video outputs when analog sync is selected (see SSST command) and an analog video signal is being generated (see AVST command). The ASRG? query returns the current setting of ASRG. See the ASSG command description for information on simultaneously controlling red, green and red sync gating. Command syntax ASRG mode mode 0 = OFF 1 = ON Query syntax Query response Other required commands Example 234 ASRG? mode The FMTU command instructs the generator to use the new setting. The ALLU command updates hardware to the new setting and redraws the test image. ASRG 1 FMTU // Enable comp sync on red in buffer // Update hardware to current buffer contents Appendix A Command Reference ASSC Analog Sync Swing Calibration factor Class Description System calibration settings Sets the analog video calibration (or scaling) factor that's used to adjust the level set by ASSS. Issuing the command with a single factor sets all three analog video channels to the same value. Issuing the command with three factors sets each of the analog video channels to each of the given values. The actual peak-to-peak swing of the analog composite sync signals at the output connectors equals the product of ASSS multiplied by ASSC. The ASSC? query returns the current settings of ASSC. The default factory setting is 1.000 for this parameter. Note: The ASSC parameter is a system level parameter that affects the analog video swing of all formats that are recalled. The ASSC value is retained when the generator is powered down and back up again. Query the current setting of ASSC if you are experiencing problems with low or missing analog composite sync levels. Reinitializing the generator's memory restores the setting to factory default values of 1.000. Command syntax ASSC red_factor, green_factor, blue_factor or ASSC common_factor factor min = 0.000 (floating point accepted) max = 1.000 (floating point accepted) Query syntax Query response Example ASSC? red_factor, green_factor, blue_factor ASSC .995 .998 1.00 FMTU Video Test Generator User Guide // Reduce red and green sync levels // Update hardware to current buffer contents 235 ASSG Analog Sync Signal Gate Class Description Command syntax Format parameter setting - Analog video signal Enables and disables adding composite sync to all three analog video outputs when analog sync is selected (see SSST command) and an analog video signal is being generated (see AVST command). This command can take the place of sending all three of the individual ASRG, ASGG, ASBG commands. The ASSG? query returns the current settings of the ASSG? ASSG red_mode, green_mode, blue_mode or ASSG common_mode mode 0 = OFF 1 = ON (0, 0, 0 or 0, 1, 0 only choices on 801GC-ISA) Query syntax Query response Other required commands Example 236 ASSG? red_mode, green_mode, blue_mode The SSST type must be 4, 5, 6 or 7 to output analog sync. The FMTU command instructs the generator to use the new setting. The ALLU command updates hardware to the new setting and redraws the test image. ASSG 0,1,0 FMTU // Enable composite sync on green in buffer // Update hardware to current buffer contents Appendix A Command Reference ASSS Analog Sync Signal Swing Class Description Command syntax Format parameter setting - Analog video signal Sets the maximum peak-to-peak swing for any composite sync that is added to any of the three analog video channels. The actual peak-to-peak swing of the analog sync signals at the output connectors equals the product of ASSS multiplied by ASSC. The ASSS? query returns the current setting of ASSS. ASSS level level min = 0.000 volts (floating point accepted) max = 0.400 volts (floating point accepted) Query syntax Query response Other required commands Example ASSS? level One or more ASSG modes must be set to ON and the SSST type must be 4, 5, 6 or 7 to output analog sync. The FMTU command instructs the generator to use the new setting. The ALLU command updates hardware to the new setting and redraws the test image. ASSS 0.286 FMTU Video Test Generator User Guide // Set sync swing to 286 mV in buffer // Update hardware to current buffer contents 237 AVCM Analog Video Calibration Method Class Description Command syntax System calibration setting Determines how the generator tests and calibrates its analog video outputs. The AVCM? query returns the current setting of AVCM. AVCM type type 0 = Interpolate 1 = Measure Interpolate 2 = Measure Set Absolute 3 = Test Levels Query syntax Query response Example 238 AVCM? type AVCM 1 // Select Measure Interpolate // type of self cal Appendix A Command Reference AVCO Analog Video COnfiguration Class Description Command syntax Format parameter setting - Analog video signal Sets the mapping of the analog video colors to the video output connections. The AVCO? query returns the current setting of AVCO. AVCO type type 0 = RGB - R to R, G to G, B to B (Normal) 1 = RBG - R to R, B to G, G to B 2 = GRB - G to R, R to G, B to B 3 = GBR - G to R, B to G, R to B 4 = BRG - B to R, R to G, G to B 5 = BGR - B to R, G to G, R to B Query syntax Query response Other required commands Example AVCO? type The FMTU command instructs the generator to use the new setting. The ALLU command updates hardware to the new setting and redraws the test image. AVCO 5 FMTU Video Test Generator User Guide // Output blue on red chan and red on blue chan // Update hardware to current buffer contents 239 AVCS Analog Video Color subcarrier Selection Class Description Command syntax Format parameter setting - Analog video signal Sets the color subcarrier type used for the television outputs on generator models that have television outputs available. The AVCS? query returns the current setting of AVCS. AVCS type type 0 = No subcarrier 1 = NTSC-M, 3.579545 MHz (American) 2 = NTSC-44, 4.43361875 MHz (conversion format without phase alternation) 3 = PAL, 4.43361875 MHz (with phase alternation) 4 = PAL-Nc, 3.58205625 MHz (Argentina) Query syntax Query response Other required commands Example 240 AVCS? type The FMTU command instructs the generator to use the new setting. The ALLU command updates hardware to the new setting and redraws the test image. AVCS 1 FMTU // Select standard American NTSC encoding // Update hardware to current buffer contents Appendix A Command Reference AVPG Analog Video Pedestal Gate Class Description Command syntax Format parameter setting - Analog video signal Enables and disables the analog video set-up pedestal. The AVPG? query returns the current setting of AVPG. AVPG mode mode 0 = OFF 1 = ON Query syntax Query response Other required commands AVPG? mode Analog video must be enabled with the AVST command in order to output an analog video signal. The pedestal level is set with the AVPS command. The FMTU command instructs the generator to use the new setting. The ALLU command updates hardware to the new setting and redraws the test image. Example AVPG 1 AVPS 7.5 FMTU Video Test Generator User Guide // Enable use of a black level pedestal // Set pedestal level to 7.5 IRE // Update hardware to current buffer contents 241 AVPS Analog Video Pedestal Swing Class Description Command syntax Format parameter setting - Analog video signal Sets a black pedestal level between the blanking level (0.0 I.R.E.) and the peak video level (100.0 I.R.E.). The AVPS? query returns the current setting of AVPS. AVPS level level min = 0.0 I.R.E. max = 100.0 I.R.E. Query syntax Query response Other required commands AVPS? level AVPG must be set to ON to enable the use of the pedestal. The FMTU command instructs the generator to use the new setting. The ALLU command updates hardware to the new setting and redraws the test image. Example AVPG 1 AVPS 7.5 FMTU 242 // Enable use of a black level pedestal // Set pedestal level to 7.5 IRE // Update hardware to current buffer contents Appendix A Command Reference AVSS Analog Video Signal Swing Class Description Command syntax Format parameter setting - Analog video signal Sets the maximum peak-to-peak swing for all three analog video channels. The actual peak-to-peak swing of the analog video signals at the output connectors equals the product of AVSS multiplied by AVSC. The AVSS? query returns the current setting of AVSS. AVSS level level 0.000 to 1.000 volts (floating point accepted) Query syntax Query response AVSS? level Other required commands Analog video must be enabled with the AVST command in order to output an analog video signal. The FMTU command instructs the generator to use the new setting. The ALLU command updates hardware to the new setting and redraws the test image. Example 1 This example uses the AVSS command changes the output level of the NTSC format from 714mV to 500mV, and adds the revised format to the format knob list. FMTL NTSC FMTB AVSS 0.5 FMTE FMTA NTSC_1 DIRL fmt DIRB NAMI 1 NTSC_01 DIRE DIRS Example 2 This example enables analog video, and sets the video swing. AVST 2 AVSS 0.714 FMTU Video Test Generator User Guide // Select RGB component color video in buffer // Set to 714 mV in buffer // Update hardware to current buffer contents 243 Example 3 This example changes the sync level from 286mV to 200mV, and sets the video output level at 500mV. FMTL FMTB ASSS AVSS FMTE FMTA 244 NTSC 0.2 0.7 NTSC_1 Appendix A Command Reference AVST Analog Video Signal Type Class Description Command syntax Format parameter setting - Analog video signal Establishes the type of signal that appears on the analog video outputs of the generator. The AVST? query returns the current setting of AVST. AVST type type 0 = none 1 = Analog Y (grayscale) 2 = Analog RGB (color) 3 = CVBS or S-Video grayscale 4 = CVBS or S-Video color 5 = Analog YPrPb (old SMPTE 240M HDTV) 6 = Analog YCrCb ITU BT.601 (ANSI/SMPTE 170M TV) 7 = Analog YPrPb SMPTE RP177 HDTV 8 = YPrPb ITU-R BT.709 HDTV Query syntax Query response Other required commands Example AVST? type DVST must be set to zero when analog video is used. The FMTU command instructs the generator to use the new setting. The ALLU command updates hardware to the new setting and redraws the test image. DVST 0 AVST 2 ALLU Video Test Generator User Guide // Disable digital video // Select RGB component color video // Update hardware and redraw test image 245 BALG dc BALancing Gate Class Description Format parameter setting - Digital video signal Enables and disables adding DC balancing to the Open LVDI digital outputs on generators that support LVDI outputs. FPD-Link compatible displays use unbalanced (BALG 0), while OpenLDI displays use balanced (BALG 1). The BALG? query returns the current setting of BALG. Command syntax BALG mode mode 0 = OFF 1 = ON Query syntax Query response Other required commands 246 BALG? mode FMTU or ALLU Appendix A Command Reference BASE number BASE Class Description Direct processor control Establishes the radix of address and data parameters passed to or returned from the ADDR, GETA, GETR, PUTA, PUTR, and CALL commands. If a negative radix is specified, then parameters passed to (or returned from) these functions are assumed to be signed. For example, if BASE= -16, then the value -1 communicates the value FFFFFFFF hex. The BASE? query returns the current setting of BASE. The radix radix always is passed and returned in base 10, regardless of the setting of BASE. BASE is preset to -10 each time the generator is powered on. Base -10 is the preferred radix. The BASE? query returns the current setting of BASE. Note: This command is used only with custom applications and command files created by Quantum Data. Command syntax BASE radix radix -36 to -2 or 2 to 36 Query syntax Query response BASE? radix Video Test Generator User Guide 247 BLUG BLUe Gate Class Description Command syntax Video Gate Toggles the blue video signal gate. BLUG mode mode 0 disable 1 enable Query syntax Query response Other required commands BLUG? 0 or 1 ALLU to invoke the command. Related commands GRNG, REDG Example BLUG 0; ALLU 248 Appendix A Command Reference // disable blue video component BOIT BOot and IniTialize Class Description Command syntax System control Initializes the generator without going through a self-calibration. BOIT Video Test Generator User Guide 249 BOOT warm BOOT Class Description Command syntax 250 System control Causes the generator to go through its standard power-up procedure. Self-calibration is not performed. The procedure checks all RAM storage locations for corrupt data. This command is equivalent to turning the generator off and then on. BOOT Appendix A Command Reference BRAT Bit RATe Class Description Format parameter setting - Digital audio signal Sets the bit rate (in Hz) for an external compressed audio source. This sets the MBR parameter of the Audio InfoFrame (as specified in EIA/CEA-861-B). The BRAT? query returns the current compressed digital audio bit rate Command syntax BRAT rate rate 0.0 (audio is not compressed) 8000, 16000, 24000 (or higher multiple of 8,000) Query syntax Example Related commands BRAT? BRAT 32000 IFGU XAUD (MBR parameter) Video Test Generator User Guide 251 CACH instruction CACHe enable Class Description Command syntax System parameter settings Enables and disables the use of the instruction cache. The CACH? query returns the current setting of CACH. CACH mode mode 0 = OFF 1 = ON Query syntax Query response Example 252 CACH? 0 or 1 CACH 0 // Disable the use of the instruction cache Appendix A Command Reference CALF analog video CALibration Factors Class Description System calibration settings Sets the analog output calibration factors to values other than those set by the generator's own self-calibration function. Each channel is calibrated using two independent zero calibration points, and two independent slope calibration points. Interpolation equations for the different video types are used to set the caldac values that controls the output sync and voltage levels to the correct values. TV calibration uses two factors for NTSC output, and two factors for PAL output. Note: Sending bad calibration factors to the generator via the CALF command can hang the generator. If the generator hangs it will have to be reinitialized. Command syntax CALF zero500R, zero50R, slope1500R, slope1000R, zero500G, zero50G, slope1500G, slope1000R, zero500B, zero50B, slope1500B, slope1000B, ntsc714, pal700, ntsc_blank, pal_blank zero500R Red calibration factor from 0 (most negative) to 4095 (least negative) at -1.0V. zero50R Red calibration factor from 0 (most negative) to 4095 (least negative) at -100mV. slope1500R Red calibration factor from 0 (maximum swing) to 4095 (minimum swing) at 2.0V. slope1000R Red calibration factor from 0 (maximum swing) to 4095 (minimum swing) at 1.4V. zero500G, zero50G, slope1500G, slope1000R Green calibration factors. zero500B, zero50B, slope1500B, slope1000B Blue calibration factors. ntsc714 Factor from 0 (maximum swing) to 4095 (minimum swing) for NTSC output level at 714mV. The ntsc714 and ntsc_blank values are interrelated. pal700 Factor from 0 (maximum swing) to 4095 (minimum swing) for PAL output level at 700mV. ntsc_blank Factor from 0 (least negative) to 4095 (most negative) used to set the zero level of the NTSC output at 0.0 IRE. Video Test Generator User Guide 253 pal_blank Factor from 0 (least negative) to 4095 (most negative) used to set the zero level of the PAL output at 0.0 IRE. Query syntax Related commands Example 254 CALF? The AVSC command matches the levels for the three analog video channels. The ALLU command updates the signal generating hardware to the new settings and redraws the test image. CALF 1090, 2590, 1992, 3223, 1149, 2634, 2059, 3278, 1001, 2506, 1993, 3221, 781, 780, 3387, 3513 // Set new factors ALLU // Use new factors Appendix A Command Reference CALL CALL internal function Class Description Direct processor control Calls internal C functions. Address address is the entry point of the C function to be called. Parameter passed indicates the number of parameters to be passed. If passed is not zero, then parameters being passed p(1) through p(n) immediately follow the passed parameter on the command line. The CALL? query is similar to the CALL command except that returned parameters are expected. Here, a third parameter returned is added to indicate the number of parameters returned by the function. If BASE= -10 or -16 and a returned value of -1 is given (4,294,967,295 if BASE=10 or FFFFFFFF if BASE=16), then a single value is read from register A8 of the TMS34010 (rather than being popped off the C stack). Most C functions that return a single parameter return their single parameter in this way. Returned parameters are space-delimited and formatted according to the current radix (see BASE command). All parameters passed to the CALL and CALL? must be formatted according to the current radix. This includes the parameters passed and returned. Note: This command is used only with custom applications and command files created by Quantum Data. Indiscriminate use of this command can cause the generator to stop operating or loss of stored data in non-volatile RAM. Command syntax CALL address passed [ p(1) [ p(2) [ p(3) …[ p(18) ]…]]] address 0 to 4,294,967,295 (BASE = 10) -2,147,483,648 to 2,147,483,647 (BASE = -10) 0 to FFFFFFFF (BASE = 16) -80000000 to 7FFFFFFF (BASE = -16) passed 0 to 18 (BASE = -10 or 10) 0 to 12 (BASE = -16 or 16) p(n) 0 to 4,294,967,295 (BASE = 10) -2,147,483,648 to 2,147,483,647 (BASE = -10) 0 to FFFFFFFF (BASE = 16) -80000000 to 7FFFFFFF (BASE = -16) Query syntax CALL? address passed returned [ p(1) [ p(2) [ p(3) …[ p(17) ]…]]] Video Test Generator User Guide 255 address 0 to 4,294,967,295 (BASE = 10) -2,147,483,648 to 2,147,483,647 (BASE = -10) 0 to FFFFFFFF (BASE = 16) -80000000 to 7FFFFFFF (BASE = -16) passed 0 to 18 (BASE = -10 or 10) 0 to 12 (BASE = -16 or 16) returned 4,294,967,295 and 0 to 20 (BASE = 10) -1 to 20 (BASE = -10) FFFFFFFF and 0 to 14 (BASE = 16) -1 to 14 (BASE = -16 query only) p(n) 0 to 4,294,967,295 (BASE = 10) -2,147,483,648 to 2,147,483,647 (BASE = -10) 0 to FFFFFFFF (BASE = 16) -80000000 to 7FFFFFFF (BASE = -16) Query response Other required commands 256 ret(1) [ ret(2) [ ret(3) … [ ret(20) ]…]] CALL and CALL? expect and return parameters formatted according to the current radix set by the BASE command. Appendix A Command Reference CENT draw video CENTering markers Class Description Command syntax Custom image primitive Draws a small cross in the center of active video. If the format has an even number of active pixels, the vertical line is 2 pixels thick. The horizontal line is 2 pixels thick if the format has an even number of active lines. The primitive uses a single parameter, the color of the cross. CENT color color available colors Other required commands Example The FMTU command instructs the generator to use the new setting. The ALLU command updates hardware to the new setting and redraws the test image. CENT red ALLU Video Test Generator User Guide // Draw a small red cross in center of active video // Update hardware to current buffer contents 257 CROS draw a centered CROSs Class Description Command syntax Custom image primitive Draws a large centered cross that fills the active video area. The vertical line is 2 pixels thick if the format has an even number of active pixels. The horizontal line is 2 pixels thick if the format has an even number of active lines. The primitive uses a single parameter, the color of the cross. CROS color color available colors Other required commands Example 258 The FMTU command instructs the generator to use the new setting. The ALLU command updates hardware to the new setting and redraws the test image. CROS magenta ALLU Appendix A Command Reference // Draw a large cross in the center of the active video // Update hardware to current buffer contents CSPG Composite Sync Pulse Gate Class Description Command syntax Format parameter setting - Synchronization Enables and disables all of the digital composite sync outputs when digital composite sync is selected via the SSST command (SSST = 3). The CSPG? query returns the current setting of CSPG. CSPG mode mode 0 = OFF 1 = ON Query syntax Query response Other required commands Example CSPG? 0 or 1 In order to use digital composite sync, it must be selected with the SSST command. The FMTU command instructs the generator to use the new setting. The ALLU command updates hardware to the new setting and redraws the test image. CSPG 1 SSST 2 FMTU Video Test Generator User Guide // Enable dig comp sync in buffer // Choose digital comp sync type in buffer // Update hardware to current buffer contents 259 CSPP Composite Sync Pulse Polarity Class Description Command syntax Format parameter setting - Synchronization Establishes the logic sense of the digital composite sync output. The CSPP? query returns the current setting of CSPP. CSPP polarity polarity 0 = active-low (negative going pulse) 1 = active-high (positive going pulse) Query syntax Query response Other required commands Example 260 CSPP? 0 or 1 In order to use digital composite sync, it must be gated on with the CSPG command and selected with the SSST command. The FMTU command instructs the generator to use the new setting. The ALLU command updates hardware to the new setting and redraws the test image. CSPG 1 CSPP 1 SSST 2 FMTU // // // // Enable Select Choose Update Appendix A Command Reference dig comp sync in buffer active hi in buffer digital comp sync type in buffer hardware to current buffer contents CTLM ConTroL Mask Class Description Command syntax Format parameter setting - Digital video signal Sets the masked control bits for the LVDS output. The control bits are not always required by receivers. There are two bits that can be set: CTL00 and CTL01. CTLM mask mask 0 = sets bit low 1 = sets bit high Query syntax CTLM? Example CTLM 2 CTLM 3 Related commands // // the 2 in hex sets the CTL01 bit to 1. the 3in hex ets the CTL00 and CTL01 bits to 1. RCTL Video Test Generator User Guide 261 CXAR Content Aspect Ratio Class Description Command syntax Format parameter setting - HDMI Active Video Sets the aspect ratio of the source image content. CXAR aspect_ratio aspect_ratio 0.75 to ˜2.39 The following table provides a listing of established aspect ratios. Aspect Ratio Symbol 0.750 OT or T90 Description Television Portrait 0.800 OG or G90 1.000 1.250 1.333… Q G T (A)1 Workstation Graphics Portrait Quadrate, "Square” Workstation Graphics SDTV / Silent Film ˜1.37 C (B)1 1.444… 1.500 I V (T)1 Academy2 “Classic” with sound IMAX™ Vista Vision™ 1.555… M (V)1 Mid 1.600 D 16 Decimal 1.666… 1.750 E Z European Film, "1.66 Old Film 1.777… ˜1.85 H A (F)1 HDTV Film Standard (USA) 2.000 ˜2.20 U F (M)1 Univisum™ “Flat”, MPEG "20x9” ˜2.39 B (C)1 Anamorphic Cinema, “2.35”3 Examples 3x4, 480x640, 600x800, 768x1024, 960x1280, 1200x1600 4x5, 1024x1280, 1280x1600 1x1, 512x512, 1024x1024 5x4, 1280x1024, 1600x1280 4x3, 640x480, 800x600, 1024x768, 1280x960, 1600x1200 ˜4x3, 0.825x0.602 SMPTE RP40 35mm "C" 13x9, IMAX™ 3x2, 1152x768 Apple Computer (uncropped) Vista Vision™ 14x9, AFD Shoot and Protect (half-way between 4x3 and 16x9) 16x10, 1728x1080, 1280x800, see VESA CVT 1.0 5x3, 1200x720, 1280x768, 1800x1080 7x4, Old Metro-Goldwyn-Mayer and Disney Films 16x9, 1280x720,1920x1080 ˜13x7, 1280x692, 1920x1038, 0.825x0.446 SMPTE RP40 35mm "A" 2x1, 1280x640, 1920x960 "˜11x5, 1280x582, 1920x874, 1.912x0.870 SMPTE RP91 70mm ˜12x5, 1280x536, 1920x804, 1.650x0.690 SMPTE RP40 35mm "B" 1. The letters in parenthesis are the letters that we used to use, before we updated our aspect ratio symbols for compatibiliity with existing film industry standards (i.e. the symbols defined in SMPTE RP40). 2. In 1932, the shape of film was changed from 1.33:1 to 1.37:1 in order to better accommodate the new optical soundtrack that was added a few years earlier. This slightly wider shape is the true aspect ratio of “classic” film. The aperture is commonly referred to as “Academy” and was the shape of the vast majority of U.S. films produced until the 1950s. 3. Sometimes called “2.35”, which was the aspect ratio before it was changed to 2.39:1 in 1971 to keep splices from showing up in the projected image. 262 Appendix A Command Reference Related commands Example EXAR, SXAR CXAR 1.33 //Sets 4:3 picture aspect ratio for source content FMTU Video Test Generator User Guide 263 DACA Digital Audio Channels Available Class Description Command syntax Format parameter setting - Audio signal Specifies which audio channels are active. DACA mask mask 0 to 3, based on following table. Channel Bit 1 0 2 1 Value 1 2 Normally, each type of audio content is assigned to a particular channel and is always output on that channel when present. There is one exception to this rule: rear center (RC) content is switched from channel 5 to 7 whenever rear left (RL) content is simultaneously present. To simplify this, RC content is thus treated as if it were two different types of content: RC5 and RC7. When RL content is not present, RC content is output on channel 5 as RC5 content. When RL content is present, RC content is output on channel 7 as RC7 content. Setting DACA will automatically set DAXA and XAUD:CA parameters to a corresponding value (see table below). DACA DAXA 3 3 XAUD:CA 0 Note: If DACA is set to a value not found in the table above, then other parameters will not be automatically set and an error will be generated if the format is loaded while this condition exists. mask 0 to 255 (based on the value in the table below).Notes: 264 • Setting DACA will automatically set DAXA and XAUD:CA parameters to a corresponding value (see table below). However, in the case of DACA values 243, 247, 251, and 255, two sets of DAXA and XAUD:CA values are possible. In this case, DAXA and XAUD:CA settings will be based on those highlighted (in grey) in the table. • If DACA is set to a value not found in the table above, then other parameters will not be automatically set and an error will be generated if the format is loaded while this condition exists. Appendix A Command Reference Example Related commands DACA 3 //specifies audio channels 1 and 2 DACG 3 //gates audio channels 1 and 2 FMTU DACG Video Test Generator User Guide 265 DACG Digital Audio Channel Gate Class Description Command syntax Format parameter setting - Audio signal Specifies which audio channels are gated (on). DACG mask mask 0 to 3 (based on the value in the table below). Channel Bit Value Example Related commands 266 1 0 1 2 1 2 DACA 3 //specifies audio channels 1 and 2 DACG 3 //gates audio channels 1 and 2 FMTU DACA Appendix A Command Reference DADG Digital Audio Down-mix Gate Class Description Command syntax Format parameter setting - Audio signal Enables or disables downmixing of an audio signal. This sets the DM_I parameter of the Audio InfoFrame (as specified in EIA/CEA-861-B, table 24). DADG mode mode 1 = enable 0 = disable Example Related commands DADG 1 FMTU IFGU XAUD (DMI parameter), DALS Video Test Generator User Guide 267 DALS Digital Audio Level Shift Value Class Description Command syntax Format parameter setting - Audio signal Sets the level shift value (in decibels) for downmixing of the audio signal. This sets the LSV parameter of the Audio InfoFrame (as specified in EIA/CEA-861-B, table 23). DALS x x 0 - 15 (dB) Example Related commands 268 DALS 5 FMTU IFGU XAUD (LSV parameter), DADG Appendix A Command Reference DASI Digital Audio Signal Interface Class Description Command syntax Format parameter setting - Audio signal Sets the digital audio signal interface. DASI interface interface 0 = none 1 = SPDIF Example DASI 1 IFGU Video Test Generator User Guide 269 DAST Digital Audio Signal Type Class Description Command syntax Format parameter setting - Audio signal Sets the digital audio signal type for an audio signal. This sets the CT parameter of the Audio InfoFrame (as specified in EIA/CEA-861-B, table 19). DAST type type 0 = void 1 = IEC 60958-3 Consumer LPCM Example Related commands 270 DAST 1 IFGU XAUD (CT parameter) Appendix A Command Reference DAXA Digital Audio Content Available Class Description Command syntax Format parameter setting - Audio signal Specifies which speaker locations are available (present). DAXA mask mask 0 to 3 (based on the value in the table below). Normally, each type of audio content is assigned to a particular channel and is always Content Bit Value FR 1 2 FL 0 1 output on that channel when present. There is one exception to this rule: rear center (RC) content is switched from channel 5 to 7 whenever rear left (RL) content is simultaneously present. To simplify this, RC content is thus treated as if it were two different types of content: RC5 and RC7. When RL content is not present, RC content is output on channel 5 as RC5 content. When RL content is present, RC content is output on channel 7 as RC7 content. Setting DAXA will automatically set DACA and XAUD:CA parameters to a corresponding value (see table below). However, this method should not be used to gate channels. Instead, DAXG should be used after all of the available channels have been selected. DAXA DACA XAUD:CA 3 3 0 Note: If DAXA is set to a value not found in the table above, then other parameters will not be automatically set and an error will be generated if the format is loaded while this condition exists. Example Related commands DAXA 3 //specifies FR and FL as having audio content DAXG 3 //gates FR and FL content FMTU DAXG Video Test Generator User Guide 271 DAXG Digital Audio Content Gate Class Description Command syntax Format parameter setting - Audio signal Specifies which speaker locations are gated (on). DAXG mask mask 0 to 3 (based on the value in the table below). Example Related commands 272 Content Bit FR 1 FL 0 Value 2 1 DAXA 3 //specifies FR and FL as having audio content DAXG 3 //gates FR and FL content FMTU DAXA Appendix A Command Reference DCBM Display Code Bit Mask Class Description Command syntax Query syntax Query response Other required commands Example Direct processor control Sets the 4-bit binary bit mask used by the DCRD? query. The mask is entered as the decimal equivalent of a 4-bit binary number. The binary number represents the masking of the individual sense lines from M3 (MSB) to M0 (LSB). The DCBM? query returns the current setting of DCBM. DCBM mask mask 0=0000 8=1000 1=0001 9=1001 2=0010 10 = 1 0 1 0 3=0011 11 = 1 0 1 1 4=0100 12 = 1 1 0 0 5=0101 13 = 1 1 0 1 6=0110 14 = 1 1 1 0 7=0111 15 = 1 1 1 1 DCBM? mask The FMTU command instructs the generator to use the new setting. The ALLU command updates hardware to the new setting and redraws the test image. DCBM 7 FMTU Video Test Generator User Guide // Set mask to read sense lines 0, 1 and 2 only // Update hardware to current buffer contents 273 DCEX Display Code EXpected Class Description Format parameter settings Sets up the display code that is expected from a display connected to the generator. The code is determined by one or more sense lines being connected to ground by the display. Many video controller cards for the Apple Macintosh II and VGA type cards for the IBM-PC sample the status of the display code sense lines. The information then sets up one of several different operating modes to match a particular display. An improper display code may make the controller card or display appear to malfunction. The DCEX? query first performs a logical AND operation with the display code bit mask and the actual display code that's sensed. The decimal equivalent of the result then is returned. The mask is set with the DCEX command. The expected setting and the actual result are both shown in the Format test image. They have no effect how a given format generates a set of test signals. Command syntax Query syntax Query response Other required commands Example 274 DCEX code code 0=0000 8=1000 1=0001 9=1001 2=0010 10 = 1 0 1 0 3=0011 11 = 1 0 1 1 4=0100 12 = 1 1 0 0 5=0101 13 = 1 1 0 1 6=0110 14 = 1 1 1 0 7=0111 15 = 1 1 1 1 DCEX? code The FMTU command instructs the generator to use the new setting. The ALLU command updates hardware to the new setting and redraws the test image. DCBM 7 DCEX 5 FMTU // Set mask to read sense lines 0, 1 and 2 only // Only lines 0 and 1 should be grounded // Update hardware to current buffer contents Appendix A Command Reference DCPG Data Channel Power Gate Class Description Command syntax EDID and DDC control Enables and disables the +5V power signal used by the DDC channel. DCPG option option 0 = disable +5V power 1 = enable +5V power Example DCPG 0 Related commands DCPX? Video Test Generator User Guide 275 DCPX? Data Channel Power Overcurrent Class Description Query syntax Returns EDID and DDC control Queries the status of the 5V display data channel (DDC) power level. DCPX? 0 or 1 0 = OK 1 = overcurrent (for example, shorted) Example DCPX? 0 Related commands DCPG 276 Appendix A Command Reference DCRD? Display Code ReaD Class Description Query syntax Query response Other required commands Example Direct processor control Returns the display code detected on the monitor sense lines as filtered through the display code bit mask. Converting the returned decimal number to a 4-bit binary number shows the status of the individual sense lines from M3 (MSB) to M0 (LSB). DCRD? code code 0=0000 8=1000 1=0001 9=1001 2=0010 10 = 1 0 1 0 3=0011 11 = 1 0 1 1 4=0100 12 = 1 1 0 0 5=0101 13 = 1 1 0 1 6=0110 14 = 1 1 1 0 7=0111 15 = 1 1 1 1 DCBM sets the mask used for reading the display code. DCRD? Video Test Generator User Guide // Return current sense lines reading 277 DDCV? DDC Version supported Class Description Query syntax Query response EDID and DDC control The DDCV? query returns a status flag indicating if the generator hardware supports VESA DDC communications. DDCV? 0 or 1 0 = no DDC support 1 = DDC supported Example 278 DDCV? // Return DDC support information Appendix A Command Reference DELX slider image DELta X Class Description Command syntax Image editor control Sets the amount of horizontal shift that occurs for each step of the SlideG and SlideRGB built-in images. The command is also used to set the horizontal size of the white patch used in the Regulate image. The DELX? Query returns the current DELX setting. DELX delta_x delta_x horizontal distance in pixels Query syntax DELX? Query response delta_x Example DELX DELY DWEL IMGL IMGU 8 3 2 “SlideG” Video Test Generator User Guide // // // // // Set H shift to 8 pixels per step Set V shift to 3 pixels per step Display each step for 2 frames Select Image that uses DELX and DELY Draw the Image 279 DELY slider image DELta Y Class Description Command syntax Image editor control Sets the amount of vertical shift that occurs for each step of the SlideG and SlideRGB built-in images. The command is also used to set the vertical size of the white patch used in the Regulate image. The DELY? Query returns the current DELY setting. DELY delta_y delta_y vertical distance in pixels Query syntax DELY? Query response delta_y Example Description Command syntax Example Related commands 280 DELX DELY DWEL IMGL IMGU 8 3 2 “SlideG” // // // // // Set H shift to 8 pixels per step Set V shift to 3 pixels per step Display each step for 2 frames Select Image that uses DELX and DELY Draw the Image Updates hardware with new EDID contents. DIDU XDID 8 3 DE33FF DIDU XDID Appendix A Command Reference DIRA DIRectory save As Class Description Command syntax Directory memory management Saves the current contents of the directory edit buffer using the given name. DIRA name name a valid MS-DOS filename (8 characters minus any extension) Example DIRA MY_DIR Video Test Generator User Guide // Save with the name "MY_DIR" 281 DIRB DIRectory editing Begin Class Description Command syntax Other required commands Example Directory memory management Marks the beginning of a directory editing session. This command does nothing in the current firmware version, but is used for compatibility with future versions of firmware. DIRB Use either a DIRL command to load an existing directory or a DIRN command to create a new directory. Use DIRE when ending the editing session. DIRN DIRB // Initialize directory edit buffer // Start directory editing session // DIRE 282 One or more directory editing commands ... // End directory editing session Appendix A Command Reference DIRE DIRectory editing End Class Description Command syntax Other required commands Example Directory memory management Marks the end of a directory editing session. This command does nothing in the current firmware version, but is used for compatibility with future versions of firmware. DIRE Use DIRB when starting the editing session. Use EDID and DDC controlDIRA or DIRS to save changes. DIRB // Start directory editing session // One or more directory editing commands ... DIRA MYDIR_02 DIRE Video Test Generator User Guide // Save edited directory as MYDIR_02 // End directory editing session 283 DIRK DIRectory Kill Class Description Command syntax Directory memory management Deletes a directory by name. The query returns a one if the named directory can be deleted. If directory is read-only or nonexistent, the query returns a zero. DIRK name name a valid MS-DOS filename (8 characters minus any extension) Query syntax DIRK? name name a valid MS-DOS filename (8 characters minus any extension) Query response Example 284 0 or 1 DIRK MY_DIR // Delete directory called "MY_DIR" Appendix A Command Reference DIRL DIRectory Load Class Description Directory memory management Copies the directory having a name equal to name from directory memory into the directory edit buffer. The query returns a one if the named directory can be loaded; otherwise, a zero is returned. Note: Use the FMTP, IMGP and SEQP commands to select which directory is used for the format, image, and sequence selection lists. Command syntax DIRL name name a valid MS-DOS filename (8 characters minus any extension) Query syntax DIRL? name name a valid MS-DOS filename (8 characters minus any extension) Query response Example 0 or 1 DIRL MY_DIR Video Test Generator User Guide // Load "MY_DIR" directory in edit buffer 285 DIRN DIRectory New Class Description Command syntax Directory memory management Initializes the directory edit buffer. The name name is assigned as the directory's name. The query will return the name that has been assigned as the directory's name. DIRN name name optional valid MS-DOS filename (8 characters minus any extension) Query syntax Example DIRN? DIRN // Init edit buffer without assigning a new name or DIRN MY_DIR 286 // Init edit buffer with name of "MY_DIR" Appendix A Command Reference DIRP DIRectory Path Class Description Command syntax Directory memory management Sets the current directory path name. The query will return the current directory path name. DIRP name name a valid MS-DOS filename (8 characters minus any extension) Query syntax Query response Example DIRP? name DIRP DIRPTH01 Video Test Generator User Guide // Set directory path to DIRPTH01 287 DIRQ? DIRectory Query pointer Class Description Query syntax Directory memory management Returns the number directory names from the list of all the directory names stored in directory memory beginning at index. The directories are kept in alphanumeric order. DIRQ? index number index positive integer number number positive integer number Query response Example List of specified directory names DIRQ? 1 5 // List the first five directories in memory or DIRQ? 1 9999 288 Appendix A Command Reference // List all directories in memory DIRS DIRectory Save Class Description Example Directory memory management Saves the current directory edit buffer contents into directory memory using the current name of the directory in the edit buffer. DIRN fmtnew DIRB NAMI 1 myfmt1 . . . NAMI n myfmtn DIRE DIRS Video Test Generator User Guide // creates a new format directory (knob list) name // begins a directory editing session // adds myfmt1 to directory (knob list) // add other formats to directory (knob list) // adds myfmtn to directory (knob list) // ends the directory editing session // saves the directory 289 DMAP Dimension bitMAP Class Description Command syntax Bitmap image control Defines the size of a rectangular bitmap array in the edit buffer. The width and height, in pixels is set by the width and height parameters. The number of data bits per pixel is set by the bpp parameter. DMAP width height bpp width min = max = height min = max = bpp 1, 2 or 4 Query syntax Query response Example 290 DMAP? width height bpp DMAP 32 20 4 Appendix A Command Reference // Set bitmap array to 32 pixels wide by 20 pixels high // and a depth of 4 bits-per-pixel DNUM Display sequence step NUMbers Class Description Command syntax Sequence editor commands Enables and disables the addition of the sequence step number to the displayed test image when running a sequence. DNUM mode mode 0, 1 or 2 Query syntax Query response Example DNUM? mode DNUM 1 Video Test Generator User Guide // Enable the displaying of the sequence step # 291 DPGU Data Island Packet Generator Use Class Description Data packet generator Updates the hardware with content of the current Data Island packet. Command syntax DPGU Related Commands DPTG Example 1 Turn mute on: XGCP 1 0 DPTG 7 DPTR 1 DPGU Example 2 Read mute status: R:MUTE? R:1 Example 3 Turn mute off: XGCP 0 1 DPTG 7 DPTR 1 DPGU Example 4 Read mute status: R:MUTE? R:0 Example 5 Change the N value to 6000, and let hardware determine CTS value: XACR 6000 DTPG 7 DPGU // You can read N and CTS value at the reciever for verification. Example 6 Change the N value to 6000, and CTS to 8000: XACR 6000 8000 DTPG 7 DPGU // You can read N and CTS value at the reciever for verification. 292 Appendix A Command Reference Example 7 Turn audio off: DPTG 3 DPGU Example 8 Turn audio on: DPTG 7 DPGU Video Test Generator User Guide 293 DPTG Data Island Packet Type Gate Class Description Data packet generator Gates on or off the assigned packet type (Audio Sample, Audio Clock Regeneration, or General Control Packet) to be updated by the hardware and sent to the receiver. Gating Audio Sample packets on and off also enables and disables the audio output from the transmitter. The mask value is a value ORed with the current setting. Command syntax DPTG mask mask 1 = General Control Packet (GCP) 2 = Audio Clock Regeneration (ACR) 4 = Audio Sample 8 = Generic Data Packet (GDP) Related commands Example DPGU, DPTR This example gates off the audio (the current value is 7): DPTG 3; DPGU See DPGU for other examples. 294 Appendix A Command Reference DPTR Data Island Packet Type Repeat Mask Class Description Data packet generator Specifies if a General Control packet is sent with every frame or sent once. Note: Audio Sample and ACR packets are always enabled (and thus cannot be changed). Command syntax DPTR mask mask 1 = General Control Packet (GCP) 8 = Generic Data Packet (GDP) Example See DPGU for examples. Video Test Generator User Guide 295 DSCT Digital Sync Composite Type Class Description Command syntax Format parameter setting - Digital video signal Establishes the type of composite sync that appears at the digital composite sync outputs when digital composite sync is selected via the SSST command. The DSCT? query returns the current setting of DSCT. A setting of zero (0) indicates that digital composite sync cannot be activated by the operator. DSCT type type 0 = none 10 = American HDTV w/serr & eq 11 = European HDTV w/serr 12 = European HDTV w/serr & eq 13 = Japanese HDTV ORed 14 = Japanese HDTV w/serr 15 = Japanese HDTV w/serr & eq Query syntax Query response Other required commands Example 296 DSCT? type The FMTU command instructs the generator to use the new setting. The ALLU command updates hardware to the new setting and redraws the test image. DSCT 2 FMTU // Select simple Amer ORed in buffer // Update hardware to current buffer contents Appendix A Command Reference DSST Digital Sync Separate Type Class Description Format parameter setting - Digital video signal Establishes the type of digital separate sync that appears at the digital HS and VS outputs of the generator when digital composite sync is selected via the SSST command and the outputs are gated on via the HSPG and VSPG commands. The only difference between EIA and CCIR digital separate syncs is that, in the case of CCIR, the width of the vertical sync pulse is 0.5 line shorter than the width specified via the VSPW command. In the EIA case, the width of the vertical sync pulse is as programmed. After sending the DSST command, send the FMTU or ALLU command. Command syntax DSST type type 0 = none 1 = American separate 2 = American HDTV separate 3 = European HDTV separate 4 = Japanese HDTV separate 5 = European separate Query syntax Query response Example DSST? Returns the current setting of DSST. A setting of zero (0) indicates that separate digital H&V sync cannot be activated by the operator. DSST 1 FMTU // Update hardware to current buffer contents Video Test Generator User Guide 297 DVIC Digital Video Identification Code Class Description Command syntax InfoFrame Generator (IFG) parameter Writes the specified Video Identification Code (VIC) into the AVI InfoFrame. DVIC code code 0 = unestablished format 1 - 34 = DVIC code corresponding to a format defined in EIA/CEA-861-B standard (Section 4). See table below for DVIC codes. Note: For detailed information about these timings, refer to the Quantum Data Web site at: http://www.quantumdata.com/support/downloads/802bt/hdmi/TimingsEIA-861-B.pdf. DVIC 1 1 2 2 2 2 3 3 4 4 5 5 6 6 6 6 7 7 8 8 8 8 8 8 8 8 9 9 9 9 10 298 Format Name DMT0659 DMT0660 480p59 480p60 480p59LH 480p60LH 480p59SH 480p60SH 720p59 720p60 1080i29 1080i30 480i2x29 480i2x30 480i2xL1 480i2xL2 480i2xS1 480i2xS2 240p2x_1 240p2x_2 240p2x_3 240p2x_4 240p2xL1 240p2xL2 240p2xL3 240p2xL4 240p2xS1 240p2xS2 240p2xS3 240p2xS4 480i4x29 Appendix A Command Reference NCPP1 1 1 1 1 1 1 1 1 1 1 1 1 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 1 SXAR2 A A A A A A A A H H H H A A A A A A A A A A A A A A A A A A A SXEX2 N0 N0 N0 N0 Lcbb Lcbb S S N0 N0 N0 N0 N0 N0 Lcbb Lcbb S S N0 N0 N0 N0 Lcbb Lcbb Lcbb Lcbb S S S S N0 CXAR2 A A A A H H H H H H H H A A H H H H A A A A H H H H H H H H A TUNE3 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 HRES4 640 640 720 720 720 720 720 720 1280 1280 1920 1920 720 720 720 720 720 720 720 720 720 720 720 720 720 720 720 720 720 720 2880 VTOT5 525 525 525 525 525 525 525 525 750 750 1125 1125 525 525 525 525 525 525 262 262 263 263 262 262 263 263 262 262 263 263 525 DVIC 10 10 10 11 11 12 12 12 12 12 12 12 12 13 13 13 13 14 14 14 14 15 15 16 16 17 17 18 19 20 21 21 22 23 23 23 23 23 23 24 24 24 25 25 26 27 27 27 27 27 27 28 Video Test Generator User Guide Format Name 480i4x30 480i4xL1 480i4xL2 480i4xS1 480i4xS2 240p4x_1 240p4x_2 240p4x_3 240p4x_4 240p4xL1 240p4xL2 240p4xL3 240p4xL4 240p4xS1 240p4xS2 240p4xS3 240p4xS4 480p2x59 480p2x60 480p2xL1 480p2xL2 480p2xS1 480p2xS2 1080p59 1080p60 576p50 576p50LH 576p50SH 720p50 1080i25 576i2x25 576i2xLH 576i2xSH 288p2x_1 288p2x_2 288p2x_3 288p2xL1 288p2xL2 288p2xL3 288p2xS1 288p2xS2 288p2xS3 576i4x25 576i4xLH 576i4xSH 288p4x_1 288p4x_2 288p4x_3 288p4xL1 288p4xL2 288p4xL3 288p4xS1 NCPP1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 2 2 2 2 2 2 1 1 1 1 1 1 1 2 2 2 2 2 2 2 2 2 2 2 2 1 1 1 1 1 1 1 1 1 1 SXAR2 A A A A A A A A A A A A A A A A A A A A A A A H H A A A H H A A A A A A A A A A A A A A A A A A A A A A SXEX2 N0 Lcbb Lcbb S S N0 N0 N0 N0 Lcbb Lcbb Lcbb Lcbb S S S S N0 N0 Lcbb Lcbb S S N0 N0 N0 Lcbb S N0 N0 N0 Lcbb S N0 N0 N0 Lcbb Lcbb Lcbb S S S N0 Lcbb S N0 N0 N0 Lcbb Lcbb Lcbb S CXAR2 A H H H H A A A A H H H H H H H H A A H H H H H H A H H H H A H H A A A H H H H H H A H H A A A H H H H TUNE3 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 HRES4 2880 2880 2880 2880 2880 2880 2880 2880 2880 2880 2880 2880 2880 2880 2880 2880 2880 720 720 720 720 720 720 1920 1920 720 720 720 720 1920 720 720 720 720 720 720 720 720 720 720 720 720 2880 2880 2880 2880 2880 2880 2880 2880 2880 2880 VTOT5 525 525 525 525 525 262 262 263 263 262 262 263 263 262 262 263 263 525 525 525 525 525 525 1125 1125 625 625 625 750 1125 625 625 625 312 313 314 312 313 314 312 313 314 625 625 625 312 313 314 312 313 314 312 299 DVIC 28 28 29 29 30 31 32 32 33 34 34 Format Name 288p4xS2 288p4xS3 576p2x50 576p2xLH 576p2xSH 1080p50 1080p23 1080p24 1080p25 1080p29 1080p30 NCPP1 1 1 1 2 2 1 1 1 1 1 1 SXAR2 A A A A A H H H H H H SXEX2 S S N0 Lcbb S N0 N0 N0 N0 N0 N0 CXAR2 H H A H H H H H H H H TUNE3 0 0 0 0 0 0 1 0 0 1 0 HRES4 2880 2880 720 720 720 1920 1920 1920 1920 1920 1920 VTOT5 313 314 625 625 625 1125 1125 1125 1125 1125 1125 1. The generator treats double-clocking and pixel repetition as two totally separate items. NCPP controls the number of clocks per pixel, while NPPP controls pixel repetition factor. All library formats set pixel repetition factor NPPP to zero (i.e. OFF) by default. Double-clocking and pixel repetition cannot be applied simultaneously due to AVI:RP field constraints. Therefore, double-clocked formats do not support pixel repetition. Pixel repetition is only applicable to the "4x" formats, where HRES remains at 2880-pixels as the pixel repetition factor NPPP is varied between 1 and 10 - thereby varying the effective resolution. 2. EXCX and EXAR are not listed here, because all library formats set EXCX and EXAR equal to N0 and CXAR, respectively. These values may be subsequently changed by rendering a special test image called "AFDtest", after the base format has finished loading, in order to evaluate different AFD cases. 3. TUNE is a flag that indicates whether the frequencies of a format have been detuned or not. A value of one indicates that all of the frequencies of a format have been tuned by a factor of 1/1.001 for NTSC compatibility. A value of zero, on the other hand, indicates that the format has not been so tuned. 4. Double-clocked formats have the same horizontal resolution as single-clocked formats - the horizontal active (as we define it), is not doubled in the double-clocked case. Some formats are distinguished by a horizontal active that is 4-times the normal value of 720. Here, pixel repetition may be applied, by a special "PixelRep" test image, after the format has loaded. The "PixelRep" test image allows the number of pixels-per-pixel (NPPP) to be varied and an image with repeated pixels to be rendered for test purposes. 5. Some formats are distinguished by having a slightly different vertical line total. Related commands Example 300 XAVI (see VIC parameter), DVIC 23 FMTU Appendix A Command Reference DVPT Digital Video Protocol Type Class Description Command syntax Format parameter setting - Digital video signal Controls the output protocol. Setting the DVPT parameter to 2 and issuing a FMTU (or ALLU) command causes the output signal protocol to switch to HDMI, while setting DVPT to 1 causes a DVI compatible protocol to be output. All of the formats in the format library set DVPT to 0. This is a default setting, which lets the output protocol be determined, on a global basis, by the type of hardware that is present. DVPT type type 0 = default (based on hardware present) 1 = DVI 1.0 2 = HDMI 1.0 Example DVPT 2 FTMU Video Test Generator User Guide 301 DVQM Digital Video Quantization Mode Class Description Format parameter setting - Digital video signal Controls the gamut of digital signals per the EIA/CEA-861-B standard. The DVQM? query returns the current DVQM mode. Command syntax DVQM mode mode Use the following table to determine the proper mode (0, 1, or 2). NBPC=8 gamuts DVQ Mode Components 0 1 2 NBPC=10 gamuts NBPC=12 gamuts LMIN LMAX LMIN LMAX LMIN LMAX RGB 0 255 0 1023 0 4095 YCbCr 0 255 0 1023 0 4095 RGB 1 254 4 1019 16 4079 YCbCr 1 254 4 1019 16 4079 RGB 16 235 64 940 256 3760 YCbCr 16 240 64 960 256 3840 Notes: Query syntax Example Related commands 302 • Computer (for example, DMT and CVT) formats set DVQM=0 for full gamut. • DVQM can be set to 1 to test the undershoot/overshoot signal code margins (for example, see SMPTE 296M section 7.12). • Television formats (for example, 1080i29) set DVQM=2 for reduced gamut required by various television standards (for example, EIA/CEA-861-B). DVQM? DVQM 1 FMTU LMIN, LMAX, NBPC Appendix A Command Reference DVSC Digital Video Swing Calibration factor Class Description Command syntax System calibration setting Sets the TMDS differential swing calibration factor for the digital video signal (HDMI and DVI). The DVSC query returns the current value. DVSC factor factor 0.0 to 1.1 Query syntax Related commands Examples DVSC? DVSS DVSC 0.9 ALLU Video Test Generator User Guide // sets the digital video swing calibration to 0.9 303 DVSI Digital Video Signal Interface Class Description Command syntax Format parameter setting - Digital video signal Determines which of the three interfaces on the 802R-PCI-D generator the digital output is applied. There are three digital interfaces on this PCI generator: LVDS, TTL and DVI. DVSI interface interface 1 = TTL 2 = LVDS 3 = DVI Query syntax Example 304 DVSI? DVSI 3 ALLU // Puts the generator digital output on the DVI interface // Applies the setting to the generator Appendix A Command Reference DVSM Digital Video Sampling Mode Class Description Command syntax Format parameter setting - Digital video signal Controls how the color difference components (CbCr) are sampled when YCbCr signal type is selected. Set DVST to a signal type that supports the sampling mode specified by DVSM. DVSM mode mode 0 = RGB 4:4:4 (default) 2 = 4:2:2 (color difference components are sampled at half the pixel rate; luminance is sampled at full pixel rate) 4 = 4:4:4 (both luminance and color difference components are sampled at the pixel rate) Related commands Examples NBPC, DVST DVST 10 DVSM 0 FMTU DVST 13 DVSM 2 FMTU Video Test Generator User Guide 305 DVSP Digital Video Signal Polarity Class Description Command syntax Format parameter setting - Digital video signal Establishes the logic sense of the digital video outputs. The DVSP? query returns the current setting of DVSP. DVSP polarity polarity 0 = active-low (negative going video) 1 = active-high (positive going video) Query syntax DVSP? Query response polarity Other required commands Example 306 To use the digital video outputs, digital video must be enabled with the DVST command. The FMTU command instructs the generator to use the new setting. The ALLU command updates hardware to the new setting and redraws the test image. AVST 0 DVST 5 DVSP 1 FMTU // // // // Deselect analog video in buffer Select 3 bit color in buffer Select active high video in buffer Update hardware to current buffer contents Appendix A Command Reference DVSS Digital Video Signal Swing Class Description Format parameter setting - Digital video signal Sets the TMDS differential swing voltage for the digital video signal. The DVSS query returns the current value. The DV_Swing image can also be used to adjust the digital swing. Command syntax DVSS voltage voltage 0.0 to 2.0 volts differential peak-to-peak (nominally 1.000, 0.150 to 1.560 range guaranteed) Query syntax Related commands Examples DVSS? DVST, DVSC DVSS 1.25 ALLU Video Test Generator User Guide // sets the digital video signal swing voltage to 1.25 volts 307 DVST Digital Video Signal Type Class Description Format parameter setting - Digital video signal Establishes the kind of video signal that exits the digital video signal outputs of the generator. The DVST? query returns the current setting of DVST. Command syntax DVST type type 0 = none 10 = RGB 13 = YCbCr (per SMPTE 260M-1999, Table 1) 14 = YCbCr (per ITU-R BT.601-5 Table 3, Item 7) 15 = YCbCr (per ITU-R BT.709-5 Part 1, Section 6.10) Query syntax Related commands Example 308 DVST? AVST must be set to zero when digital video is used. Use the ALLU or FMTU command, after the DVST command, to update the hardware with the new settings. AVST 0 DVST 10 FMTU // Deselect analog video in buffer // Select digital RGB // Update hardware to current buffer contents Appendix A Command Reference DWEL slider image DWELl time Class Description Command syntax Image Control – System Level Sets the how long each step of the SlideG and SlideRGB built-in images is displayed before the image is updated. The delay is based on the number of vertical frame refreshes that must occur for the currently loaded video format. The command is also used to set how long each step of the Regulate image is displayed. The DWEL? query returns the current DWELL setting. DWEL delay delay integer representing number of video frames Query syntax DWEL? Query response delay Example DELX DELY DWEL IMGL IMGU 8 3 2 “SlideG” Video Test Generator User Guide // // // // // Set H shift to 8 pixels per step Set V shift to 3 pixels per step Display each step for 2 frames Select Image that uses DELX and DELY Draw the Image 309 EDID? EDID read Class Description Query syntax Query response Related commands Example EDID and DDC control Reads all bytes in the base EDID and up to seven extensions from a DDC compliant display connected to the transmitter on the generator. The data is returned in raw ASCII hex format. EDID? ASCII hex test string I2CR? This example reads a four block E-EDID. R:\edid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ppendix A Command Reference EQUA EQUalization interval After vertical sync pulse Class Description Command syntax Format parameter setting - synchronization Establishes the width of the equalization interval after the vertical sync pulse in each field whenever a serrated and equalized sync type is selected via either ASCT or DSCT commands and selected via the SSST command. If the type specified for the selected sync signal is one of the CCIR types, then the actual equalization interval output by the generator will be 0.5 lines shorter than the whole number specified. The EQUA? query returns the current setting of EQUA. EQUA lines lines min = 0 max = number of lines after vertical sync before video Query syntax Query response Other required commands Example EQUA? lines The FMTU command instructs the generator to use the new setting. The ALLU command updates hardware to the new setting and redraws the test image. EQUA 3 FMTU Video Test Generator User Guide // Set post-equalization to 3 lines in buffer // Update hardware to current buffer contents 311 EQUB EQUalization interval Before vertical sync pulse Class Description Command syntax Format parameter setting - synchronization Establishes the width of the equalization interval before the vertical sync pulse in each field whenever a serrated and equalized sync type is selected via either ASCT or DSCT commands and selected via the SSST command. If the type specified for the selected sync signal is one of the CCIR types, then the actual equalization interval output by the generator will be 0.5 lines shorter than the whole number specified. The EQUB? query returns the current setting of EQUB. EQUB lines lines min = 0 max = number of lines after video and before vertical sync Query syntax Query response Other required commands Example 312 EQUB? lines The FMTU command instructs the generator to use the new setting. The ALLU command updates hardware to the new setting and redraws the test image. EQUB 3 FMTU // Set pre-equalization to 3 lines in buffer // Update hardware to current buffer contents Appendix A Command Reference EQUF EQUalization Flatten Class Description Command syntax Format parameter setting - synchronization Determines if composite sync will have all equalization pulses removed in the vertical sync front porch (delay) period as required by certain military HOBO and Maverik video formats. The EQUF? query returns the current setting of EQUF. EQUF mode mode 0 = OFF 1 = ON Query syntax Query response Other required commands Example EQUF? mode The FMTU command instructs the generator to use the new setting. The ALLU command updates hardware to the new setting and redraws the test image. EQUF 0; ALLU Video Test Generator User Guide // This is the default 313 ERRC ERRor queue Clear Class Description Command syntax 314 System error control Clears all errors waiting to be reported in the error queue. ERRC Appendix A Command Reference ERRQ? ERRor Queue Class Description Command syntax System error control Returns number errors from the list of all errors in the error queue beginning at index. The ERRQ? query does not remove the errors from the queue. ERRQ? index number index Positive integer number number Positive integer number Query response Examples: List of specified range of errors in the error queue. ERRQ? 1 5 // List the first five errors in the queue or ERRQ? 1 9999 Video Test Generator User Guide // List all errors in the queue 315 ERRY? Yank ERRor from queue Class Description Query syntax Query response 316 Format parameter setting - synchronization Returns the most recent error added to the error queue and removes it from the queue. ERRY? Error Appendix A Command Reference EXAR EXtended Aspect Ratio Class Description Format parameter setting - HDMI active video Sets the aspect ratio of the extended image content. Note: If the source image content was shot for a single screen shape, then this parameter will be the same as the CXAR parameter. Alternatively, if the source image content was shot for two different shaped screens (using a “shoot and protect” technique), then this parameter will be different than the CXAR parameter. Command syntax EXAR aspect_ratio aspect_ratio 0.75 to ˜2.39 Note: For a listing of established aspect ratios, see the table on page 262 (CXAR command). Related commands Example CXAR, SXAR EXAR 1.77 // Sets 16:9 picture aspect ratio for extended image content FMTU Video Test Generator User Guide 317 EXCX Extended-From-Content Aperture Map Class Description Command syntax Format parameter setting - HDMI active video Maps CXAR-shaped image content into the extended EXAR-shaped aperture. EXCX code code 0 to 131071 (in decimal) The mapping code is made up of three binary field codes as follows: • Bits 0-2 are the Squeeze/Stretch (“S”) field code • Bits 3-9 are the Letterbox/Pillar (“L”) field code • Bits 10-16 are the Safe Area (“K”) field code To determine the proper mapping code, follow these steps: 1. Using the table below, determine the proper “S” field code for bits 0-2. Squeeze/Stretch Method Disabled (scaling is uniform) Linear Squeeze (anamorphise) 318 Appendix A Command Reference “S” Field Code Undo Non-Linear Squeeze Bit 2 Bit 1 Bit 0 Symbol 0 0 0 0 0 1 S 2. Using the table below, determine the proper “L” field code for bits 3-9. “L” Field Code BarContents Position Shrink Bit 71 Bit 61 Bit 5 Bit 4 Bit 3 Symbol 0 0 0 0 0 Undo Bit 9 0 Bars Bit 8 0 Centered shrink w/black bars top & bottom 0 1 0 0 0 0 1 Lcbb Centered shrink w/gray bars top & bottom 0 1 0 1 0 0 1 Lcgb Centered shrink w/white bars top & bottom 0 1 1 0 0 0 1 Lcwb Centered protected shrink w/shot surround 0 0 0 0 0 0 1 Lcsp Top shrink w/single black bar at bottom 0 1 0 0 0 1 1 Ltbb Top shrink w/single gray bar at bottom 0 1 0 1 0 1 1 Ltgb Top shrink w/white bar at bottom 0 1 1 0 0 1 1 Ltwb Letterbox/Pillar Mode Disabled 1. Bits 6 and 7 are used to sequence redundant AFD codes. In the case of pixel repetition (NPPP not equal to 0), the color of the (extended) bars on the left and right sides of the image are filled in accordance with the settings of bits 6 and 7—even when the letterbox/pillar fitting method is disabled (bit 3 = 0). 3. Use the following table to determine the proper “K” field code for bits 10-16. “K” Field Code BarContents Source Bit 14 Bit 13 Bit 12 0 0 0 Undo Bit 16 0 Bars Bit 15 0 Shrink coded frame to action area with opaque black bar surround 0 1 0 0 0 0 1 Kabb Shrink coded frame to action area with opaque gray bar surround 0 1 0 1 0 0 1 Kagb Shrink coded frame to action area with opaque white bar surround 0 1 1 0 0 0 1 Kawb Coded frame has shot-protected action area without graticules or bars 0 0 0 0 0 0 1 Kasp Coded frame has shot-protected action area with action graticules without bars 0 0 0 1 0 0 1 Kaspa Coded frame has shot-protected action area with title graticules without bars 0 0 1 0 0 0 1 Kaspt Coded frame has shot-protected action area with action and title graticules without bars 0 0 1 1 0 0 1 Kaspb Shrink coded frame to title area with opaque black bar surround 0 1 0 0 0 1 0 Ktbb Shrink coded frame to title area with opaque gray bar surround 0 1 0 1 0 1 0 Ktgb (Keep) Safe Area Mode None (w/safe area markers) Video Test Generator User Guide Save Area Bit 11 Bit 10 Symbol 0 0 319 “K” Field Code BarContents Source Bit 14 Bit 13 Bit 12 1 0 0 Undo Bit 16 0 Bars Bit 15 1 Coded frame has shot-protected title area without graticules or bars 0 0 0 0 0 1 0 Ktsp Coded frame has shot-protected title area with action graticules without bars 0 0 0 1 0 1 0 Ktspa Coded frame has shot-protected title area with title graticules without bars 0 0 1 0 0 1 0 Ktspt Coded frame has shot-protected title area with action and title graticules without bars 0 0 1 1 0 1 0 Ktspb Coded frame has shot-protected custom area without graticules or border 0 0 0 0 0 1 1 Kcsp Coded frame has shot-protected custom area with action graticules without border 0 0 0 1 0 1 1 Kcspa Coded frame has shot-protected custom area with title graticules without border 0 0 1 0 0 1 1 Kcspt (Keep) Safe Area Mode Shrink coded frame to title area with opaque white bar surround 320 Appendix A Command Reference Save Area Bit 11 Bit 10 Symbol 1 0 Ktwb The following table provides mapping codes used by AFD (see XAFD). Method Natural aspect ratio Binary Field Code 00000000000000000 Decimal Code 0 Symbol N0 00000000000010000 16 N1 00000000000100000 32 N2 Squeeze (anamorphise) 00000000000000001 1 S Centered protected shrink with shot surround 00000000000001000 8 Lcsp Centered shrink with black bars top and bottom 00000000100001000 264 Lcbb Top shrink with single black bar at bottom 00000000100011000 280 Ltbb Shrink coded frame to title area w/ opaque black bar surround 01000100000000000 34816 Ktbb Related commands Example CXAR, EXAR, SXCX, SXEX EXCX 8 // Use centered protected shrink w/shot surround mode FMTU Video Test Generator User Guide 321 FDTA Font DaTA Class Description Writes font data. It takes as arguments table (the table from which to read), index (the index of the item within the table), and value (the data to be written to the table). The FDTA? query reads font data. It takes as arguments table (the table from which to read) and index (the index of the item within the table). It returns value (the data to be written to the table). The table argument must be one of the following: • 0 = The header, treated as an uint16[ ]. • 1 = The character pattern, an uint32[ ]. • 2 = The location table, an uint16[ ]. • 3 = The offset/width table, an uint16[ ]. • 4 = The image width table, an uint8[ ]. Note: The index range for table #0 must be: 0 = index 13. The index range for the other tables depends on the font size. Command syntax FDTA table index value table positive integer number index positive integer number value positive integer number Query syntax FDTA? table index table positive integer number index positive integer number Related commands 322 FDTA Appendix A Command Reference FLSH FLaSH new firmware via GPIB Class Description System Level Changes the firmware in the generator’s flash EPROM via the GPIB port. This is accomplished by sending an IEEE 488.2 standard arbitrary block program data to the generator. The generator temporarily places the block in picture memory and, if received intact, eventually transfers the binary image to flash memory by internally executing the VTOF function. Note that one does not have to send VTOF after a FLSH transfer. FLSH initiates the data transfer. An arbitrary_block_program_data argument containing either 512K or 2M bytes of binary data should follow this command per standard IEEE-448.2 section 7.7.6 GPIB data transfer methods. Command syntax FLSH arbitrary_block_program_data arbitrary_block_program_data IEEE-488.2 arbitrary block program data per standard IEEE-448.2 section 7.7.6 GPIB data transfer method. The maximum number of bytes sent depends on the generator: 801requires a maximum of 524288 bytes, while 802 requires a maximum of 2097152 bytes. Related commands Example YMDI, VTOF FLSH #6524288 …EPROM data bytes… Video Test Generator User Guide 323 FMTA ForMaT save As Class Description Command syntax Format memory management Saves the current contents of the format edit buffer using the given name FMTA name name a valid MS-DOS filename (8 characters minus any extension) Example 324 FMTA MY_FMT // Save with the name "MY_FMT" Appendix A Command Reference FMTB ForMaT editing Begin Class Description Command syntax Other required commands Example Format editor control Marks the beginning of a format editing session. FMTB Use either an FMTL command to load an existing image or an FMTN command to create a new format. Use FMTE when ending the editing session. FMTN FMTB // Initialize format edit buffer // Start format editing session // One or more format editing commands ... FMTE Video Test Generator User Guide // End format editing session 325 FMTE ForMaT editing End Class Description Command syntax Other required commands Example Format editor control Marks the end of a format editing session. FMTE Use FMTB when starting the editing session. Use FMTA or FMTS to save changes. FMTB // Start format editing session // One or more format editing commands ... FMTA My_fmt1 FMTE 326 Appendix A Command Reference // Save edited format as My_fmt1 // End format editing session FMTG? ForMaT in buffer Good Class Description Query syntax Query response Example Format memory management Tests the format in the format buffer for errors. If no errors are found, FMTG? returns zero. Otherwise, if one or more errors exist, the number of the first error encountered is returned. To test formats residing in format memory, use the FMTT? query. FMTG? Returns 0 if no errors are found; otherwise, returns the number of the first error encountered. FMTG? Video Test Generator User Guide // Return format error status 327 FMTJ ForMaT Justify Class Description Format memory management Corrects some types of timing errors for the current data in the format buffer. The following errors are corrected: • Pixel Rate errors 2071 and 2072 • Video Memory Size error 2550 • Horizontal Blanking errors 2140, 2141, 2150 and 2155 • Horizontal Total errors 2090 and 2091 • Horizontal Sync Pulse Width errors 2181 and 2201 The justification routine tries to keep the format close to your original specifications. However, the format should be reviewed after it is justified to make sure it still meets your timing requirements. Command syntax Other required commands Example 328 FMTJ The FMTU command instructs the generator to use the new settings. The ALLU command updates hardware to the new settings and redraws the test image. The FMTG? query can be used to see if any errors remain. FMTJ FMTU // Update hardware to current buffer contents Appendix A Command Reference FMTK ForMaT Kill from memory by name Class Description Command syntax Format memory management Erases the named format from memory. The FMTK? query checks to see if the named format can be erased. The RAM location number is returned if it can be erased. Otherwise, a zero is returned. FMTK name name a valid MS-DOS filename (8 characters minus any extension) Query syntax FMTK? name name valid MS-DOS filename (8 characters minus any extension) Query response Example 0 or location FMTK my_fmt1 Video Test Generator User Guide // Erase format called my_fmt1 329 FMTL ForMaT Load from memory by name Class Description Format memory management Assigns a format to the current step of a sequence while between a set of SEQB and SEQE commands. The FMTL command is context sensitive. The FMTL? query returns the name of the format currently assigned to the step. Outside of the sequence editor, the FMTL command reads the format having a name equal to name from format memory (or EPROM) into the format. FMTL does not reconfigure the signal generating hardware. This feature allows you to work on the contents of any format memory location, while continuing to output a signal based on a previously used format (see FMTU command). The FMTL? query returns the location location in which a format having a name equal to name is found. If multiple formats exist having name name, then the lowest numbered location containing a format with a matching name name is returned. The format memory (RAM) is always searched first. If a format with name name cannot be found anywhere in the format memory, then the industry-standard formats located in EPROM (negative locations) are searched next. The FMTL? query returns zero if a format with a name equal to name cannot be found in either format space. Command syntax FMTL name name a valid MS-DOS filename (8 characters minus any extension) Query syntax Query response Other required commands Example 330 FMTL? name location (returns 0 if not found) The ALLU command updates the hardware to the new settings and redraws the test image. FMTL VGA_m3 ALLU // Load format called VGA_m3 // Update hardware and redraw image Appendix A Command Reference FMTN ForMaT New Class Description Format memory management Initializes the format editing buffer. Sending this one command is equivalent to sending all of the following commands: ASBG 0 GAMA 2.2 ASCT 1 GAMC 0 ASGG 1 HRAT 0 ASSG 0, 1, 0 HRES 0 ASSS 0.286 HSIZ 280 AVPG 0 HSPD 0 AVPS 0.0 HSPG 1 AVSB 0.0 HSPP 0 AVSS 0.714 HSPW 0 AVST 0 HTOT 0 XVSG 1, 1, 1 SCAN 1 CSPG 1 SSST 1 CSPP 0 USIZ 2 DCBM 0 VRES 0 DSEX 0 VSIZ 210 DSST 1 VSPD 0 DVSP 0 VSPG 1 DVST 0 VSPP 0 EQUA 0 VSPW 0 EQUB 0 VTOT 0 This should be the first command sent to the generator when creating a new format. The command only resets to a known state. The command does not create a usable format. The FMTN? query returns the current name of the format in the buffer. Command syntax FMTN name name a valid MS-DOS filename (8 characters minus any extension) Query syntax FMTN? Video Test Generator User Guide 331 Query response Example name FMTN // Initialize format buffer or FMTN Narf 332 // Initialize format buffer and name the format "Narf" Appendix A Command Reference FMTP ForMaT Path Class Description Command syntax Format memory management Sets the current format path name to a given directory. The query will return the current format path name. FMTP name name a valid MS-DOS filename (8 characters minus any extension) Query syntax Query response Example FMTP? name DIRQ? FMT IMG VGA_FMTS SEQ // List directory objects FMTP VGA_FMTS // Load a custom format knob list FMTP FMT Video Test Generator User Guide // Load the default format knob list 333 FMTQ? ForMaT Query pointer Class Description Query syntax Format memory management Returns number format names from the list of all the formats stored in format memory beginning at index. The formats are kept in alphanumeric order. The generator maintains internal variables for the current index and number values. The value of index is automatically incremented by number after the query is executed. Sending the query with just an index parameter returns the same number of names as the last time, starting at the given index. Sending the query with no parameters, returns the next set of names. FMTQ? [index [number]] index positive integer number number positive integer number Query response Example List of specified format names FMTQ? 1 9999 // List all formats in memory or FMTQ? 1 10 FMTQ? 21 FMTQ? 334 Appendix A Command Reference // List the first ten formats in memory // List the 21st through the 30th FMTes in memory // List the 31st through the 40th FMTes in memory FMTR ForMaT Read from memory location (by number) Class Description Command syntax Format memory management Reads format from the format memory location into the format buffer. The FMTR command does not reconfigure the signal generating hardware. The FMTR? query returns the name of the format stored in location location. FMTR? returns the string EMPTY if the format memory location location is empty. FMTR location location 1 through 300 (RAM) -1 through -24 (EPROM) Query syntax Query response Other required commands Example FMTR? location name The ALLU command updates the hardware to the new settings and redraws the test image. FMTR -5 ALLU Video Test Generator User Guide // Load format from ROM location 5 // Update hardware and redraw image 335 FMTS ForMaT Save Class Description Command syntax Example 336 Format memory management Saves the current format edit buffer contents into format memory using the current name of the format in the edit buffer. FMTS FMTL DMT0660 FMTB HRES 654 . . . HTOT 720 FMTE FMTS // Loads a format for editing // Begins and editing session // Sets the horizontal resolution to 654 pixels Appendix A Command Reference // other format parameters // Sets the horizontal total to 720 pixels // Ends the format editing session // Saves format FMTU ForMaT Use Class Description Format memory management Checks the current contents of the format buffer for errors; if no errors are found, it reconfigures the signal generating hardware in accordance with the contents. It does not redraw the previously displayed test image. In some cases this may distort the old image. The FMTU? query returns either a format memory location location or zero. If the signal format currently being output by the signal generating hardware matches that originally loaded (using the FMTL command) or read (using the FMTR command) from a format memory location, then the matching format memory location location is returned. Otherwise, if the format contents have been used to update the signal generating hardware since either an FMTR or FMTL command has been issued, then FMTU? query returns zero. Command syntax Query syntax Query response FMTU FMTU? location or 0 Video Test Generator User Guide 337 FMTZ ForMat Zap Class Description Command syntax Query syntax 338 Format memory management Clears format storage memory starting at first and ending at last. The cleared locations are then tagged as being empty. If no last parameter is given, only the first location is cleared. The FMTZ? query is used to determine if a location contains a format or is empty. FMTZ first last FMTZ? location Appendix A Command Reference FORM draw FORMat data block Class Description Custom image primitive Displays basic information about the format driving the display. The first line shows the number of horizontal active pixels and vertical active lines. The last number on the line is the number of fields per frame (1 for non-interlaced and 2 for interlaced). The second and third lines show the horizontal and vertical rates, respectively. Text is on a black rectangular background with a single pixel border. FORM uses three (3) parameters. The first is the color of the text and border. The next two are the X and Y coordinates for the top left corner of the block of text. Command syntax FORM color x y color available colors x positive integer number y positive integer number Other required commands Example The FMTU command instructs the generator to use the new setting. The ALLU command updates hardware to the new setting and redraws the test image. FORM blue 30 200 ALLU Video Test Generator User Guide // Display format information // in blue beginning at X=30, Y=200 // Update hardware to current buffer contents 339 FRAT? Frame RATe Query Class Description Query syntax Query response Example Format parameter setting - Video resolution Returns the current frame (vertical) rate setting. FRAT? frame rate FRAT? 25.0000 Related commands 340 TMAU Appendix A Command Reference FRGB Foreground Red, Green and Blue levels Class Description Command syntax System parameter settings Temporarily sets the portions of an image drawn with a color selection of foreground to the given red, green and blue values. All three colors can be set to the same level using a single parameter. The color selection for one or more primitives in a custom image must be set to foreground in order to see the affect of this command on a custom image. The setting is not global and is not saved. The FRGB? query returns the current red, green and blue settings of FRGB. FRGB red_level green_level blue_level or FRGB common_gray_level level min = 0 (full off) max = 255 (full on) Query syntax Query response Example FRGB? red_level green_level blue_level FRGB 255 128 0 // Set foreground color to orange or FRGB 128 Video Test Generator User Guide // Set foreground color to a mid-gray level 341 FSPD Frame Sync Pulse Delay Class Description Command syntax Format parameter setting - Synchronization Sets the delay of the frame sync pulse relative to the last line of active video in the current format. The FSPD? query returns the current FSPD setting. FSPD delay delay min = 0 lines max = (VTOT/SCAN) line Query syntax Query response Other required commands Example FSPD? delay To get a pulse, frame sync must first be enabled with the FSPG command. The FMTU command instructs the generator to use the new settings. The ALLU command updates the hardware to the new settings and redraws the test image. FSPG FSPP FSPW FSPG FMTU 342 1 1 20 300 // // // // // // Appendix A Command Reference Enable Frame Sync Set for positive going pulse Make the pulse 20 pixels wide Pulse to occur 300 lines after the last line of active video Update hardware to new settings FSPG Frame Sync Pulse Gate Class Description Command syntax Format parameter setting - Synchronization Enables and disables the digital horizontal sync output. The FSPG? query returns the current FSPG mode. FSPG mode mode 0 = OFF 1 = ON Query syntax Query response Other required commands Example FSPG? 0 or 1 The FMTU command instructs the generator to use the new settings. The ALLU command updates the hardware to the new settings and redraws the test image. FSPG 1 FMTU Video Test Generator User Guide // Enable Frame Sync // Update hardware to new settings 343 FSPP Frame Sync Pulse Polarity Class Description Command syntax Format parameter setting - Synchronization Establishes the logic sense of the digital frame sync output. Setting polarity to one (1) causes the leading edge of frame sync to be a low-to-high transition. Setting polarity to zero (0) causes the leading edge of frame sync to be a high-to-low transition. The FSPP? query returns the current polarity of FSPP. FSPP polarity polarity 0 = active-low (negative going pulse) 1 = active-high (positive going pulse) Query syntax Query response Other required commands Example FSPP? 0 or 1 To get a pulse, frame sync must first be enabled with the FSPG command. The FMTU command instructs the generator to use the new settings. The ALLU command updates the hardware to the new settings and redraws the test image. FSPG FSPP FSPW FSPG FMTU 344 1 1 20 300 // // // // // // Appendix A Command Reference Enable Frame Sync Set for positive going pulse Make the pulse 20 pixels wide Pulse to occur 300 lines after the last line of active video Update hardware to new settings FSPW Frame Sync Pulse Width Class Description Command syntax Format parameter setting - Synchronization Establishes the width of the frame sync pulse. The FSPW? query returns the current setting of FSPW. FSPW pixels pixels min = 1 max = HTOT - 1 Query syntax Query response Other required commands Example FSPW? pixels The FMTU command instructs the generator to use the new settings. The ALLU command updates the hardware to the new settings and redraws the test image. FSPG FSPP FSPW FSPG FMTU 1 1 20 300 Video Test Generator User Guide // // // // // Enable Frame Sync Set for positive going pulse Make the pulse 20 pixels wide Pulse to occur 300 lines after the last line of active video Update hardware to new settings 345 GAMA GAMmA correction factor Class Description Command syntax Format parameter setting - Digital video signal Establishes the current video gamma correction factor. The GAMA? query returns the current setting of the gamma correction factor. GAMA factor factor min = 0.1 (floating point accepted) max = 10.0 (floating point accepted) For HDMI video signals GAMA is always 2.222 Query syntax Query response Other required commands Example 346 GAMA? factor Gamma correction must be enabled with the GAMC command in order to use the gamma correction factor. The FMTU command instructs the generator to use the new setting. The ALLU command updates hardware to the new setting and redraws the test image. GAMC 1 GAMA 2.2 FMTU // Enable gamma correction in buffer // Set correction factor in buffer // Update hardware to current buffer contents Appendix A Command Reference GAMC GAMma Correction mode Class Description Command syntax Format parameter setting - Digital video signal Enables or disables application of the video gamma correction factor. The GAMC? query can be used to determine if the gamma correction factor is currently being applied. GAMC mode mode 0 = disable (don't correct) 1 = enable (correct) Query syntax Query response Other required commands Example GAMC? 0 or 1 The value used for gamma correction is set with the GAMA command. The FMTU command instructs the generator to use the new setting. The ALLU command updates hardware to the new setting and redraws the test image. GAMC 1 GAMA 2.2 FMTU Video Test Generator User Guide // Enable gamma correction in buffer // Set correction factor in buffer // Update hardware to current buffer contents 347 GCET? Get Component Error Tallies Class Description Query syntax Query response Example DVI signal analyzer Reads the number of errors in the red, green, and blue components along with the total number of bad pixels. GCET? R, G, B, and bad pixels PNAU //Pseudo-random noise generated CR //Stop pseudo-random noise GCET? 0,21,0,21 //Returns 21 Green pixel errors and a total of 21 bad pixels Related commands 348 PNAU Appendix A Command Reference GETA? GET data from Absolute memory location Class Description Direct processor control Returns the value of the data stored at the memory address specified. Up to 32 bits can be read with this query (see SIZE command). The returned value value is formatted according to the current setting of BASE (see the BASE command). Note: This command is used only with custom applications and command files created by Quantum Data. Query syntax GETA? address address 0 to 4,294,967,295 (BASE = 10) -2,147,483,648 to 2,147,483,647 (BASE = -10) 0 to FFFFFFFF (BASE = 16) -80000000 to 7FFFFFFF (BASE = -16) Query response Other required commands value GETAand GETA? expect and return parameters formatted according to the current radix set by the BASE command. Video Test Generator User Guide 349 GETR? GET data from Relative memory location Class Description Direct processor control Returns the value of the data stored at the memory location currently pointed to by the address register (see ADDR command). Up to 32 bits can be read with this query (see SIZE command). The returned value value is formatted according to the current setting of BASE (see the BASE command). The address register is automatically incremented by SIZE bits after the current location has been read. Note: This command is used only with custom applications and command files created by Quantum Data. Query syntax Query response Other required commands 350 GETR? value GETR and GETR? expect and return parameters formatted according to the current radix set by the BASE command. Appendix A Command Reference GFED? Get First Error Data Class Description Query syntax Query response Example DVI signal analyzer Returns information about the first error encountered. GFED? expected value followed by the errant value (in hex) PNAU //Pseudo-random noise generated CR //Stop pseudo-random noise GFED? //Returns expected (40018C) and errant (FFFFFF) value of first errored pixel 40018C,FFFFFF Related commands PNAU Video Test Generator User Guide 351 GLUT Get LUT from hardware Class Description Command syntax 352 Lookup Table Memory Management Copies the current values from the hardware lookup table to the lookup table edit buffer. GLUT Appendix A Command Reference GMAP Get pixel MAP from frame buffer Class Bitmap image control Description The GMAP command Command syntax GMAP width height x y name width height x y name Other required commands Example The contents of the temporary buffer can not be edited directly. The MAPL command must be used to copy the temporary buffer contents to the edit buffer. GMAP 3 3 5 5 thismap MAPL mymap MAPB Video Test Generator User Guide // get a new map named thismap from frame buffer // load bitmap mymap into edit buffer // begin map editing context 353 GNPT? Get Number of Pixel Tested Class Description Query syntax Query response Example Signal analyzer - Pixel data Returns the number of pixels being measured in billions after a pseudo noise measurement has finished execution (that is, completed the PNAU command). GNPT? number of pixels PNAU //Pseudo-random noise generated CR //Stop pseudo-random noise GNPT? //Returns 4.255 billion pixels 4.255 Related commands 354 PNAU Appendix A Command Reference GPEL? Get PixEL color components Class Description Query syntax Query response Possible errors Example Related commands Signal analyzer - Pixel data Takes the (x, y) coordinates address of a pixel and returns the red, green, and blue color components of the pixel at that address. GPEL? x y R, G, B Should this info be integrated into the Query response area, instead of creating a new label?The GPEL? query may respond back with one of the following errors in case of a parameter is not set correctly (or in case the setup is not correct). PNSeedExceedsLimit 2800 PNLengthExceedsLimit 2801 PNNotSupported 2802 NoInputSupported 2803 XcoordOutOfRange 2804 YcoordOutOfRange 2805 PDSX 128 PDSY 256 PDSH 64 PDSW 96 PDAU GPEL? 128 256 0,255,0 //sets patch starting at x-pixel 128 //sets patch starting at y-pixel 256 //sets patch height at 64 pixels //sets patch width at 90 pixels //captures patch of image //read RGB color components at pixel address 128,256 PDAU Video Test Generator User Guide 355 GPER? Get Pixel Error Rate Class Description Query syntax Query response Example Signal analyzer - Pixel data Returns the pixel error rate in errors per billion after a pseudo noise measurement has finished execution (that is, completed the PNAU command). GPER? pixel error rate PNAU CR //Pseudo-random noise generated //Stop pseudo-random noise GPER? //Returns 0.88 billion pixel errors 0.88 Related commands 356 PNAU Appendix A Command Reference GPIB GPIB address Class Description Command syntax GPIB port control Sets the address of the generator on the GPIB port. The address change takes affect as soon as the command is issued. The new address setting will be maintained until 1) the address is changed another GPIB command, 2) the unit is re-initialized with an INIT command or 3) the unit is re-initialized because the power-up self-test found corrupted data in battery backed system memory. In cases 2 and 3, the GPIB address will revert to the address set on the GPIB address switches, if the unit has them. The address reverts to 15 if the unit does not have GPIB address switches. The GPIB? query returns the current GPIB address of the unit. GPIB address address integer, 0-30 Query syntax Query response Example GPIB? address GPIB 5 Video Test Generator User Guide // Set GPIB address to 5 357 GRID draw a centered GRID Class Description Command syntax Custom image primitive Draws a crosshatch of a given color and forms a given number of boxes in each direction. All lines are 1 pixel thick. All of the lines in a given direction are equally spaced. Any remaining pixels are distributed as equally as possible around the perimeter of the grid. This may cause the first and last lines in each direction not to be at the very edges of video. GRID color horizontal_boxes vertical_boxes color available colors horizontal_boxes number of horizontal boxes (half of number of pixels) vertical_boxes number of vertical boxes (half of number of lines) Other required commands Example The FMTU command instructs the generator to use the new settings. The ALLU command updates the hardware to the new settings and redraws the test image. GRID gray75 14 10 ALLU 358 Appendix A Command Reference // Draw a gray75 grid with 14 horizontal // and 10 vertical boxes // Update hardware to current buffer contents GRIH draw a GRIll pattern of Horizontal lines Class Description Command syntax Custom image primitive Draws equally spaced horizontal lines that form a grill over the entire active video area. The primitive uses three parameters. The first is the color of the lines, the second is the thickness of the lines, and the third is the thickness of the space between the lines. GRIH color line_width space_width color available colors line_width number of pixels in line space_width number of pixels in space Other required commands Example The FMTU command instructs the generator to use the new settings. The ALLU command updates the hardware to the new settings and redraws the test image. GRIH green 4 6 ALLU Video Test Generator User Guide // Draw green grid with 4-pixel lines and 6-pixel spaces // Update hardware to current buffer contents 359 GRIV draw a GRIll pattern of Vertical lines Class Description Command syntax Custom image primitive Draws equally spaced vertical lines that form a grill over the entire active video area. The gaps are not touched and will show any previously drawn primitives. The primitive uses three parameters. The first is the color of the lines, the second is the thickness of the lines, and the third is the thickness of the space between the lines. GRIV color line_width space_width color available colors line_width number of pixels in line space_width number of pixels in space Other required commands Example The FMTU command instructs the generator to use the new settings. The ALLU command updates the hardware to the new settings and redraws the test image. GRIV cyan 16 16 ALLU 360 Appendix A Command Reference // Draw cyan grill with 16-pixel lines // and 16-pixel spaces // Update hardware to current buffer contents GRNG GRNe Gate Class Description Command syntax Video Gate Toggles the green video signal gate. GRNG mode mode 0 = disable 1 = enable Query syntax Query response Other required commands Related commands Example GRNG? 0 or 1 ALLU to invoke the command. BLUG, REDG GRNG 0; ALLU Video Test Generator User Guide // disable green video component 361 GTLS Go To Local State Class Description Command syntax Query syntax Query response System Control Enables the use of the front panel keys and knobs (local operation) on the unit that may have been previously disabled with the LLOS command. The GTLS? query returns the current state of local operation. GTLS GTLS? 0 or 1 0 = local state disabled (local lockout enabled) 1 = local state enabled (local lockout disabled) 362 Appendix A Command Reference HATI draw a centered crossHATch from the Inside out Class Description Command syntax Custom image primitive Draws a crosshatch from the inside-out of a given color and forms a given number of boxes in each direction. The primitive has center lines that divide the active video exactly in half in each direction. The vertical center line is 2 pixels thick if the format has an even number of active pixels. The horizontal center line is 2 pixels thick if the format has an even number of active lines. All other lines are 1 pixel thick. If you enter an odd number of boxes, a half box is placed at each end of the crosshatch. All lines in a given direction are spaced equally. Any remaining pixels are distributed as equally as possible around the perimeter of the grid. This may cause the first and last lines in each direction not to be at the very edges of video. In turn, this may cause any half boxes to be slightly larger. HATI color horizontal_boxes vertical_boxes color available colors horizontal_boxes number of horizontal boxes (half of number of pixels) vertical_boxes number of vertical boxes (half of number of lines) Other required commands Example The FMTU command instructs the generator to use the new settings. The ALLU command updates the hardware to the new settings and redraws the test image. HATI green 15 9 ALLU Video Test Generator User Guide // Draw a green grid with 15 horizontal // and 9 vertical boxes // Update hardware to current buffer contents 363 HATO draw a centered crossHATch from the Outside in Class Description Command syntax Custom image primitive Draws a crosshatch from the outside-in of a given color and forms a given number of boxes in each direction. All lines are 1 pixel thick. The first and last lines in each direction are at the very edges of active video. All the lines in a given direction are spaced equally. Any remaining pixels are added to the boxes along the horizontal and vertical centers of the image. HATO color horizontal_boxes vertical_boxes color available colors horizontal_boxes number of horizontal boxes (half of number of pixels) vertical_boxes number of vertical boxes (half of number of lines) Other required commands Example The FMTU command instructs the generator to use the new settings. The ALLU command updates the hardware to the new settings and redraws the test image. HATO yellow 15 9 ALLU 364 Appendix A Command Reference // Draw a yellow grid with 15 horizontal // and 9 vertical boxes // Update hardware to current buffer contents HDCP? HDCP Class Description: Query syntax HDCP The HDCP query is used to control HDCP tests. HDCP? [A1 | A2] [B1 | B2] [frames] A1 runs the test with public keys A1 A2 runs the test with public keys A2 B1 runs the test with public keys B1 B2 runs the test with public keys B2 frames The number of frames to be tested. The default is 512. Example HDCP? 2000 HDCP? a2 b1 2000 // run test with production keys for 2000 frames // run test with public keys a2, b1 for 2000 frames For additional examples, see “Using command-line interface to control HDCP” on page 190. Video Test Generator User Guide 365 HDMI High-Definition Multimedia Interface protocol Class Description Digital video signal control Sets the current digital protocol. Restarting the generator does not change this setting. The HDMI? query returns the current mode. Command syntax HDMI mode mode 0 to disable HDMI (use alternative protocol such as DVI 1.0) 1 to enable HDMI (default) This command affects the DVPT parameter as shown below: Interface hardware used DVI only HDMI Query syntax Query response Example 366 HDMI? 0 or 1 HDMI 0 ALLU Appendix A Command Reference HDMI setting DVPT setting 0 0 1 2 0 1 1 0 HRAT Horizontal RATe Class Description Command syntax Format parameter setting - Video resolution Sets the line frequency. Pixel rate is equal to HTOT multiplied by HRAT. Frame rate is equal to HRAT divided by VTOT. Field rate is equal to SCAN multiplied by the frame rate. The HRAT? query returns the current horizontal frequency setting. HRAT frequency frequency typical min = 1000 Hz (floating point accepted) typical max = 130000 Hz (floating point accepted) Query syntax Query response Other required commands Example HRAT? frequency in Hz (floating point returned) The FMTU command instructs the generator to use the new settings. The ALLU command updates the hardware to the new settings and redraws the test image. HRAT 32768 FMTU // Set 32.768 kHz rate in buffer // Update hardware to current buffer contents or HRAT 32.768E3 FMTU Video Test Generator User Guide // Set a 32.768 kHz rate // Update hardware to current buffer contents 367 HRES Horizontal RESolution Class Description Command syntax Format parameter setting - Video resolution Establishes the number of active pixels per line. The HRES? query returns the current setting of HRES. HRES pixels pixels min = 16 max depends on VRES and model of generator Query syntax Query response Other required commands Example 368 HRES? pixels The ALLU command updates hardware to the new setting and redraws the test image. HRES 480 ALLU // Set 480 active pixels line in buffer // Configure hardware and redraw image Appendix A Command Reference HSIZ Horizontal SIZe Class Description Format parameter setting - Video resolution Establishes the horizontal physical size of the image on the display. Units expected (or returned) vary according to the last mode set with USIZ command. The HSIZ command is context sensitive and must appear between begin and end commands FMTB and FMTE. The HSIZ? query returns the current setting of HSIZ. Note: Make sure that the USIZ parameter is properly set before using the HSIZ command. Changing the USIZ setting after entering HSIZ will convert the size to match the new unit of measure. Command syntax HSIZ physical_size physical_size positive value (floating point accepted) Query syntax Query response Other required commands Example HSIZ? Returns physical size (floating point returned) The units of measure must be properly set by USIZ before entering HSIZ. The ALLU command updates hardware to the new setting and redraws the test image, taking the new size into account. FMTB USIZ 1 HSIZ 10.4 VSIZ 7.8 ALLU FMTE Video Test Generator User Guide // // // // // // // // // Begin editing session One or more format editing commands ... Select inches as unit of measure in buffer Set width to 10.4 in buffer Set height to 7.8 in buffer Test the new settings more format editing commands ... End of editing session 369 HSPD Horizontal Sync Pulse Delay Class Description Command syntax Format parameter setting - Synchronization Establishes the delay between the leading edge of blanking and the leading edge of the horizontal sync pulse. The HSPD? query returns the current setting of HSPD. HSPD pixels pixels min = 1 max = HTOT - HRES - HSPW Query syntax Query response Other required commands Example 370 HSPD? pixels The FMTU command instructs the generator to use the new settings. The ALLU command updates the hardware to the new settings and redraws the test image. HSPD 16 FMTU // Set 16 pixel pulse delay in buffer // Update hardware to current buffer contents Appendix A Command Reference HSPG Horizontal Sync Pulse Gate Class Description Command syntax Format parameter setting - Synchronization Enables and disables the digital horizontal sync output. The HSPG? query returns the current HSPG mode. HSPG mode mode 0 = OFF 1 = ON Query syntax Query response Other required commands Example HSPG? 0 or 1 To use digital horizontal sync, digital separate H and V sync must be selected with the SSST command. The FMTU command instructs the generator to use the new settings. The ALLU command updates the hardware to the new settings and redraws the test image. HSPG 1 FMTU Video Test Generator User Guide // Enable H sync output in buffer // Update hardware to current buffer contents 371 HSPP Horizontal Sync Pulse Polarity Class Description Command syntax Format parameter setting - Synchronization Establishes the logic sense of the digital horizontal sync outputs. Setting polarity to 1 causes the leading edge of horizontal sync to be a low-to-high transition. Setting polarity to 0 causes the leading edge of horizontal sync to be a high-to-low transition. The HSPP? query returns the current polarity of HSPP. HSPP polarity polarity 0 = active-low (negative going pulse) 1 = active-high (positive going pulse) Query syntax Query response Other required commands Example 372 HSPP? 0 or 1 To use digital horizontal sync, it must be gated on with the HSPG command and digital separate H and V sync must be selected with the SSST command. The FMTU command instructs the generator to use the new settings. The ALLU command updates the hardware to the new settings and redraws the test image. HSPP 0 HSPG 1 SSST 1 FMTU // // // // Set active low H sync in buffer Enable H sync output in buffer Select H&V sync type in buffer Update hardware to current buffer contents Appendix A Command Reference HSPW Horizontal Sync Pulse Width Class Description Command syntax Format parameter setting - Synchronization Establishes the width of the horizontal sync pulse. The HSPW? query returns the current setting of HSPW. HSPW pixels pixels min = 1 max = HTOT - HRES - HSPD Query syntax Query response Other required commands Example HSPW? pixels The FMTU command instructs the generator to use the new settings. The ALLU command updates the hardware to the new settings and redraws the test image. HSPW 32 FMTU Video Test Generator User Guide // Set pulse width to 32 pixels in buffer // Update hardware to current buffer contents 373 HSRS Horizontal Sync Rate Shift Class System parameter settings 801GC, 801GC-ISA, 801GF, 801GF-ISA and 801GX only Description Command syntax Temporarily shifts the horizontal sync frequency of the generator. The first parameter controls the amount of shift (in Hz) and the second parameter controls the approximate length of time (in seconds) that the frequency is shifted, before returning to nominal. Both parameters can be entered as floating point numbers. HSRS shift_factor shift_period shift_factor should not exceed ±10% of normal horizontal rate to ensure stable operation of the generator shift_period non-negative Example 374 HSRS -100 2.5 Appendix A Command Reference // Shifts the horizontal rate of the currently running // format down by 100 Hz for about 2.5 sec. HSSC Horizontal Sync Skew Calibration Class Description Command syntax System Level Parameter Skews the horizontal pulse delay by the given number of pixels on all formats loaded after issuing the command. The skew is added to the HSPD value of the format that is loaded. The HSSC? query returns the current HSSC setting. Used for correcting HSPD errors on the 801GC, 801GC-ISA and 801GX generators. HSSC skew skew min=-10 (integer) max=+10 (integer) Query syntax Query response Example HSSC? skew HSSC 2 Video Test Generator User Guide 375 HTOT Horizontal TOTal pixels per line Class Description Format parameter setting - Video resolution Establishes the total number of pixels per horizontal line. The HTOT? query returns the current setting of HTOT. The pixel rate is equal to HRAT multiplied by HTOT. Note: The current version of the firmware does not allow you to directly enter a specific pixel rate when setting up a format. If your test specifications call for a specific pixel or dot clock rate, enter suitable values for HRAT and HTOT to give you the desired pixel rate. Command syntax HTOT pixels pixels min: 801GP = 2 801GC, GF, GX = 144 801GC-ISA, GF-ISA = 144 max: 801GP = 2048 801GC, GX = 4096 801GC-ISA = 4096 801GF, 801GF-ISA = 65,536 Query syntax Query response Other required commands Example 376 HTOT? pixels The FMTU command instructs the generator to use the new settings. The ALLU command updates the hardware to the new settings and redraws the test image. HTOT 800 FMTU // Set total to 800 // Update hardware to current buffer contents Appendix A Command Reference HVPD? Horizontal Vertical Sync Pulse Delay Class Description Query syntax Query response Example Format Parameter Setting - Synchronization Returns the pixel delay between the horizontal and vertical sync pulses. HVPD? number of pixels HVPD? // read pixel delay between HSYNC and VSYNC pulses 1 Related commands // one pixel delay None Video Test Generator User Guide 377 HVSA Horizontal Vertical Sync Adjustment Class Description Command syntax Format parameter setting - Synchronization Lengthens the serration period a given number of pixels from the format’s nominal default value as required by certain military STANAG video formats. The HVSA? query returns the current setting of HVSA. HVSA pixels pixels integer, 0 and less than HSPW Query syntax Query response Other required commands Example 378 HVSA? pixels The FMTU command instructs the generator to use the new settings. The ALLU command updates the hardware to the new settings and redraws the test image. HVSA 30; ALLU Appendix A Command Reference I2CR? I2C port Read Class Description EDID and DDC control Automatically reads data using a specified I2C protocol. This command reads data from the DDC port (if equipped), EDID, enhanced DDC (E-DDC) data, and VESA DDC/CI (DDC2Bi) data using the I2C bus. All numeric parameters are given in ASCII HEX. Note: EDID-compatible receivers use EPROMs with single-byte or double-byte addresses. The I2CR? query uses different parameters depending on the EPROM type. To determine which EPROM type is used, try both syntaxes until you can read data from the EPROM. Query syntax (EPROM with single-byte addresses) I2CR? eprom i2c_address offset #_of_bytes Query syntax (EPROM with double-byte addresses) I2CR? eprom1 i2c_address offset #_of_bytes Query syntax (DDC/CI protocol) I2CR? ddcci dst_address #_of_bytes Query syntax (E-DDC protocol) I2CR? e_ddc ddc_pointer_addr segment# i2c_address offset #_of_bytes i2c_address (hex) i2c bus address (A0, A1,...) offset (hex) address offset (in bytes) #_of_bytes (hex) number of bytes dst_address (hex) destination address ddc_pointer_addr (hex) segment pointer address segment# (hex) segment pointer number Video Test Generator User Guide 379 Example 1 This example reads a four page E-EDID, using the I2C e_ddc protocol, one page at a time. R:\>i2cr? e_ddc 60 0 a0 0 80 00FFFFFFFFFFFF004489B200050000000D0C010380502D780A0DC9A05747982712484C200 00001010101010101010101010101010101011D8018711C1620582C2500C48E2100009E8C 0AD08A20E02D10103E9600138E21000018000000FC0048444D492054560A2020202020000 000FD003B3D0F2E08000A2020202020200306 R:\>i2cr? e_ddc 60 0 a0 80 80 F002020000000000000000000000000000000000000000000000000000000000000000000 0000000000000000000000000000000000000000000000000000000000000000000000000 0000000000000000000000000000000000000000000000000000000000000000000000000 000000000000000000000000000000000000C R:\>i2cr? e_ddc 60 1 a0 0 80 02031CF149850408020106141216230907078301000065030C001000011D007251D01E206 E285500C48E2100001ED60980A020E02D1010602200128E210000188C0AD090204031200C 405500C48E21000018011D80D0721C1620102C2580C48E2100009E8C0AA01451F01600267 C4300138E21000098000000000000000000A4 R:\>i2cr? e_ddc 60 1 a0 80 80 020308F1431113158C0AD090204031200C405500138E21000018011D00BC52D01E20B8285 540C48E2100001E8C0AA02051201810187E2300C48E210000980000000000000000000000 0000000000000000000000000000000000000000000000000000000000000000000000000 0000000000000000000000000000000000071 Example 2 This command returns 128 bytes of EDID from the connected device. i2cr? e_ddc 60 0 a0 0 80 Related commands 380 EDID?, I2CW Appendix A Command Reference I2CW I2C port Write Class Description EDID and DDC control Writes raw binary data from the DDC port (if equipped), EDID, and VESA DDC/CI (DDC2Bi) data using the I2C bus. Note: EDID-compatible receivers use EPROMs with single-byte or double-byte addresses. The I2CW command uses different parameters depending on the EPROM type. Command syntax (EPROM with single-byte addresses) I2CW eprom i2c_address offset #_of_bytes data Command syntax (EPROM with double-byte addresses) I2CW eprom1 i2c_address offset #_of_bytes data Command syntax (DDC/CI protocol) I2CW ddcci dst_address src_address length [command+data+checksum] i2c_address (hex) i2c bus address (A0, A1,...) offset (hex) address offset (in bytes) #_of_bytes (hex) number of bytes data (hex) data command (hex) command checksum (hex) checksum Video Test Generator User Guide 381 Example 1 This command writes the first 8 bytes of EDID to the EPROM. Note: Always confirm that you can successfully read an address (using the I2CR? query) before writing to that address. i2cw eprom a0 0 8 00FFFFFFFFFFFF00 Example 2 This command reads the EDID from a specified address. i2cr? eprom a0 0 80 Example 3 This command writes DDC2Bi data. i2cw ddcci 6E 51 81 B10F Example 4 This commands reads the DDC2Bi data. i2cr? ddcci 6F 5 Related commands 382 EDID?, I2CR? Appendix A Command Reference IDET Initialization DETect Class Description Command syntax System Parameter Stores the integer flag value in non-volatile memory. The value is not changed except by 1) another IDET command, 2) re-initializing the unit with an INIT command, or 3) the system firmware because the power-up self test found corrupted data in battery backed system memory. In cases 2 and 3, the IDET value will revert to 0. The IDET? query returns the current IDET value. The IDET command and query are used by automated test systems to determine if a particular unit has been replaced or reinitialized since it had its IDET value set to unique number by that system. IDET integer flagNeed help with this syntax and parameter formatting. -2,147,483,647 ??integer flag?? +2,147,483,647 Query syntax Query response Example IDET? flag IDET 19980616 Video Test Generator User Guide // Set IDET to a non-zero value 383 IFGU InfoFrame Generator Use Class Description Command syntax Example Related commands 384 InfoFrame Generator (IFG) parameter Updates hardware with current InfoFrame contents. IFGU IFTG 14 IFGU IFTG, IFTR, XGIF, XAVI, XSPD, XAUD, XMPG Appendix A Command Reference IFTG InfoFrame Type Gate Class Description InfoFrame Generator (IFG) parameter Gates the InfoFrames by type. The mask value is a value ORed with the current setting. Note: For more information about the InfoFrame structure, see the EIA Standard EIA/CEA-861-B (Section 6). Command syntax IFTG mask mask A bit mask based on these InfoFrame type values. Example Type Value GIF 1 AVI 2 SPD 4 AUD 8 MPG 16 This example enables AUD (8), SPD (4), and AVI (2) InfoFrames (but not MPG and GIF InfoFrames). The MPG and GIF InfoFrames are gated off, and loaded with zeros. IFTG 14 IFGU Related commands IFGU, IFTR Video Test Generator User Guide 385 IFTR InfoFrame Type Repeat Mask Class Description InfoFrame Generator (IFG) parameter Specifies if an InfoFrame type is to be sent once (after the IFGU command is executed), or sent in every vertical blanking period (frame). Note: For more information about the InfoFrame structure, see the EIA Standard EIA/CEA-861-B (Section 6). Command syntax IFTR mask mask A bit mask based on these InfoFrame type values. Example Type Value GIF 1 AVI 2 SPD 4 AUD 8 MPG 16 This example specifies that AUD (8) and AVI (2) InfoFrames should be repeated with every frame, and other InfoFrame types should be sent once. IFTR 10 IFGU Related commands 386 IFTG, IFGU Appendix A Command Reference IMGA IMaGe save As Class Description Command syntax Image memory management Saves the current contents of the image edit buffer using the given name. IMGA name name a valid MS-DOS filename (8 characters minus any extension) Example IMGA MY_IMG Video Test Generator User Guide // Save with the name "MY_IMG" 387 IMGB IMaGe editing Begin Class Description Command syntax Other required commands Example Image editor control Marks the beginning of an image editing session. IMGB Use either an IMGL command to load an existing image or an IMGN command to create a new image. Use IMGE when ending the editing session. IMGN IMGB // Initialize image edit buffer // Start image editing session // One or more image editing // commands ... IMGE 388 // End image editing session Appendix A Command Reference IMGE IMaGe editing End Class Description Command syntax Other required commands Example Image editor control Marks the end of an image editing session. IMGE Use IMGB when starting the editing session. Use IMGA or IMGS to save changes. IMGB // Start image editing session // One or more image editing commands ... IMGA MYIMG_02 IMGE Video Test Generator User Guide // Save edited image as "MYIMG_02" // End image editing session 389 IMGK IMaGe Kill Class Description Command syntax Image memory management Deletes an image by name. The query returns a 1 if the named image can be deleted. If the image is read-only or nonexistent, the query returns a 0. IMGK name name a valid MS-DOS filename (8 characters minus any extension) Query syntax IMGK? name name a valid MS-DOS filename (8 characters minus any extension) Query response Example 390 0 or 1 IMGK MY_IMG // Delete dir called "MY_IMG" Appendix A Command Reference IMGL IMaGe Load Class Description Image memory management Assigns an image to the current step of a sequence while between a set of SEQB and SEQE commands. The IMGL command is context sensitive. The IMGL? query returns the name of the image currently assigned to the step. Outside of the sequence editor, the IMGL command copies the image having a name equal to name from image memory into the image edit buffer. The query returns a one (1) if the named image can be loaded, otherwise a zero (0) is returned. Command syntax IMGL name name a valid MS-DOS filename (8 characters minus any extension) Query syntax IMGL? name name a valid MS-DOS filename (8 characters minus any extension) Query response Other required commands Example 0 or 1 An ALLU or IMGU command must be executed after the IMGL command to cause the image in the edit to draw on the unit under test. IMGL MY_IMG IMGU Video Test Generator User Guide // Load "MY_IMG" dir in edit buffer // Draw contents of buffer 391 IMGN IMaGe New Class Description Command syntax Image editor control Initializes the image edit buffer. The name name is assigned as the image's name. The query will return the name that has been assigned as the image's name. IMGN name name optional valid MS-DOS filename (8 characters minus any extension) Query syntax Query response Example IMGN? name IMGN // Init edit buffer without assigning a new name or IMGN MY_IMG 392 // Init edit buffer with name of "MY_IMG" Appendix A Command Reference IMGP IMaGe Path Class Description Command syntax Image memory management Sets the current image path name to a given directory. The query will return the current image path name. IMGP name name a valid MS-DOS filename (8 characters minus any extension) Query syntax IMGP? name name a valid MS-DOS filename (8 characters minus any extension) Query response Example name IMGP FINAL Video Test Generator User Guide // Sets image pathname to a directory called "FINAL". 393 IMGQ? IMaGe Query pointer Class Description Query syntax Image memory management Returns number image names from the list of all the images stored in image memory beginning at index. The images are kept in alphanumeric order. IMGQ? index number index positive integer number number positive integer number Query response Example List of specified image names IMGQ? 1 5 // List the first five images in memory or IMGQ? 1 9999 394 Appendix A Command Reference // List all images in memory IMGR IMaGe Read image from image memory location Class Description Command syntax Image memory management Copies the image residing in the image memory with location location into the image buffer. The IMGR command does not cause the selected image to be drawn. See the IMGU command for actually drawing the image. Using the IMGL command to load images by name is the preferred method of selecting images. IMGR location location -1 through -26 (EPROM) Other required commands Example The IMGU command draws the image. The ALLU command updates hardware to the new setting and redraws the test image. IMGR 1 IMGU Video Test Generator User Guide // Select first custom image in memory // Draw the image 395 IMGS IMaGe Save Class Description Command syntax 396 Image memory management Saves the current contents of the generator's custom image edit buffer back to the memory location from which it was originally read. IMGS Appendix A Command Reference IMGU IMaGe Use Class Description Command syntax Image memory management Draws an image based on the current contents of the image. The IMGU? query returns the image memory location location from which the current contents of the image were read. See the IMGR command for setting the contents of the image. IMGU Query syntax IMGU? Query response location location -1 through -26 (EPROM) Example IMGL BriteBox IMGU Video Test Generator User Guide // Select the BriteBox test image // Draw the selected test image 397 INIT INITialize to factory default settings Class Description Direct processor control Restores the contents of all of the generator's RAM storage locations to factory-default conditions. The generator then goes through a complete self-test and self-calibration procedure. Important: The INIT command permanently and irreversibly removes all user-created formats, custom images, test sequences, and directories from memory. Command syntax 398 INIT Appendix A Command Reference ISTP? Image STep Class Description Query syntax Image editor control Allows the contents of user created custom images to be copied out of a generator. The contents of the firmware-based, built-in test images cannot be read out since they are not created as a set of primitives. ISTP? returns the number of steps in the custom image in the edit buffer. or ISTP? step_number returns the contents of the given step in the custom image in the edit buffer as a space delimited text string. Other required commands A custom image must have been loaded with the IMGL command and editing must have been started with the IMGB command Video Test Generator User Guide 399 ISUB Image Step Button Class Description System parameter settings Determines if the Image Step key is on or off to allow activation of alternate versions of test images that have alternate versions. The ISUB? query returns the current setting of ISUB. Command syntax ISUB mode mode 0 = OFF 1 = ON Query syntax Query response Example 400 ISUB? 0 or 1 IMGL SlideBox ISUB 1 IVER 1 IMGU Appendix A Command Reference // // // // Load image Enable alternate versions Load version 1 Update display IVER Image VERsion Class Description System parameter settings Determines which version of an image is used for the current step of a sequence while between a set of SEQB and SEQE commands. The IVER command is context sensitive. The IVER? query returns the version currently assigned to the step. Outside of the sequence editor, the IVER command selects which version of the current image is drawn when either an ALLU or IMGU command is executed. The IVER? query returns the current setting of IVER. Command syntax IVER mode mode 0 = Normal 1 = Invert or display alternate version Query syntax Query response Other required commands Example IVER? 0 or 1 The IMGU command redraws an image using the new setting. The ALLU command updates hardware and redraws the test image with the new setting. IMGL Text_9 IVER 1 IMGU Video Test Generator User Guide // Select image with white text on black // Select inverted with black on white // Draw the image as selected 401 JDVI Justify pixel clock rate for DVI formats Class Description Command syntax Format editor control Scales the horizontal timing parameters of the format currently in the edit buffer. The parameters are scaled to produce the given pixel rate while keeping the horizontal scan rate as close as possible to its original value. The following parameters are scaled: horizontal total pixels, horizontal active pixels, horizontal sync delay in pixels, and horizontal sync pulse width in pixels. The parameters are scaled so that their periods, in microseconds, are as close as possible to their original values. JDVI pixel_rate pixel_rate floating point number equal to the desired pixel in MHz Query syntax Query response Other required commands 402 JDVI? pixel_rate The ALLU command updates hardware to the new settings and redraws the test image. Appendix A Command Reference JLDI Justify pixel clock rate for LDI formats Class Description Command syntax Format editor control Scales the horizontal timing parameters of the format currently in the edit buffer. (For the 801LD used in digital mode, the default is set at 224 MHz.) The parameters are scaled to produce the given pixel rate while keeping the horizontal scan rate as close as possible to its original value. The following parameters are scaled: horizontal total pixels, horizontal active pixels, horizontal sync delay in pixels, and horizontal sync pulse width in pixels. The parameters are scaled so that their periods, in microseconds, are as close as possible to their original values. JLDI pixel_rate pixel_rate floating point number equal to the desired pixel in MHz Query syntax Query response Other required commands JLDI? pixel_rate The ALLU command updates hardware to the new settings and redraws the test image. Video Test Generator User Guide 403 JRAT Justify pixel clock RATe Class Description Command syntax Format editor control Scales the horizontal timing parameters of the format currently in the edit buffer. The parameters are scaled to produce the given pixel rate while keeping the horizontal scan rate as close as possible to its original value. The following parameters are scaled: horizontal total pixels, horizontal active pixels, horizontal sync delay in pixels, and horizontal sync pulse width in pixels. The parameters are scaled so that their periods, in microseconds, are as close as possible to their original values. JRAT pixel_rate pixel_rate floating point number equal to the desired pixel in MHz Other required commands Example 404 The ALLU command updates hardware to the new settings and redraws the test image. JRAT 202.000E6 // Adjust timing to a 202.000 MHz clock FMTU // Update hardware to current buffer contents Appendix A Command Reference KEYY KEY toggle Class Description Command syntax System parameter settings Toggles the status of the following items: image version of the currently displayed image, red, green and blue video gating, ACS, DCS, and DSS sync gating, and outputs gating. The order of the keys matches the order of the keys found on the front panel of the generator. The current status of the keys can be checked using the LEDS?? query. KEYY key key 1 = image (step) version 2 = red gating 3 = green gating 4 = blue gating 5 = ACS gating 6 = DCS gating 7 = DSS gating 8 = outputs gating Example KEYY 8 Video Test Generator User Guide // Toggle current status of output gates 405 KNOB rotate KNOB Class Description System parameter settings Mimics turning the Format or Image knob on the generator. When a sequence is running, the Format knob loads sequences from the directory selected by the SEQP command. Clockwise rotation increases the index pointer for the directory. The Image knob is used to go back and forth through the sequence steps. Clockwise rotation selects higher step numbers. Command syntax KNOB number clicks number 1 = upper Format knob 2 = lower Image knob clicks An integer representing the number of knob increments from the current active format or image. A positive integer indicates a clockwise move to a higher index number. A negative integer indicates a counterclockwise move to a lower index number. Example 406 KNOB 2 1 // Move Image knob 1 click CW KNOB 1 -10 // Move the Format knob 10 clicks CCW Appendix A Command Reference LCDS? LCD Status Class Description Query syntax Example System parameter settings Returns text displayed on LCD of the generator. LCDS? LCDS? Video Test Generator User Guide // Return text similar to text below // H32 15=VGA_m3 crlf // V60 51=SMPTE133 407 LEDS? LED Status Class Description System parameter settings Returns the current status of the generator's signal generating hardware as a single decimal number. The number corresponds to the status of the lighted key on the generator in normal operation. The easiest way to interpret the number is to first convert it to an 8-digit binary number. A 1 in a given position, from MSB to LSB, corresponds to the following hardware settings: Master output control gated ON (MSB) Digital Separate (HS&VS) Sync selected Digital Composite Sync selected Analog Composite Sync selected Blue video enabled Green video enabled Red video enabled Alternate image version selected Query syntax Query response Example LEDS? decimal number from 0 to 255 LEDS? // Returns the following number when the outputs are gated ON, separate // HS & VS is selected, the red, green and blue video channels are // enabled and the primary version of an image is selected. 206 408 (LSB) // Binary equivalent = 11001110 Appendix A Command Reference LIMI draw video LIMIts markers Class Description Command syntax Custom image primitive Places nine markers that define the active video area. An L-shaped marker is placed at each corner. T-shaped markers are centered along each edge of video, and a small cross is placed at the center of video. The primitive uses a single parameter: color. LIMI color color available colors Other required commands Example The FMTU command instructs the generator to use the new setting. The ALLU command updates hardware to the new setting and redraws the test image. LIMI white ALLU Video Test Generator User Guide // Place white markers that define active video area // Update hardware to current buffer contents 409 LINE draw a LINE Class Description Command syntax Custom image primitive Draws a line between any two points. The line is 1 pixel thick. The primitive uses five parameters: the color and x,y coordinates for both endpoints. LINE color x_start y_start x_end y_end color available colors x_start, y_start, x_ end, y_end positive integer number Other required commands Example The FMTU command instructs the generator to use the new setting. The ALLU command updates hardware to the new setting and redraws the test image. LINE yellow 20 5 320 240 // Draw yellow line from X=20, Y=5 to X=320, Y=240 ALLU 410 // Update hardware to current buffer contents Appendix A Command Reference LLOS Local Lock Out State Class Description Command syntax Query syntax Query response System Control Enables the use of the front panel keys and knobs (local operation) on the generator that may have been previously disabled with the GTLS command. The LLOS? query returns the current local lockout state. LLOS LLOS? status 0 = local lockout disabled 1 = local lockout enabled Example LLOS Video Test Generator User Guide // Disable the use of front panel controls 411 LMAX Lut MAXimum level (Analog) Class Description Command syntax Lookup Table memory management Establishes the maximum integer lookup table level representing full white. LMAX level level integer min = 0 max = 65,535 Query syntax Example 412 LMAX? LMAX 1024 Appendix A Command Reference LMAX Digital Video Maximum quantizing Level Class Description Command syntax Format parameter setting - Digital video signal Sets the maximum quantizing level of the component video signal for white. The default varies depending on the number of bits per color component. Some applications may require that the maximum level be set lower than the maximum permissible. The query reads the current setting for the maximum level. LMAX video_level video_level unsigned integer from 59 to 63 when NBPC is 6 gamuts; 235 to 255 when NBPC is 8 gamuts; 940 to 1023 when NBPC is 10 gamuts; 3760 to 4095 when NBPC is 12 gamuts. Query syntax Example Related commands LMAX? LMAX 254 // To set the maximum digital quantizing level to 254 LMIN, NBPC, DVQM Video Test Generator User Guide 413 LMIN Digital Video Minimum quantizing Level Class Description Command syntax Format parameter setting - Digital video signal Sets the minimum quantizing level of the component video signal for black. The default is 0 for black; however, some applications may require that the minimum level be set higher. The query reads the current setting for the minimum level. LMIN video_level video_level unsigned integer from 0 to 4 when NBPC is 6 gamuts; 0 to 16 when NBPC is 8 gamuts; 0 to 64 when NBPC is 10 gamuts; 0 to 256 when NBPC is 12 gamuts Query syntax Example Related commands 414 LMIN? LMIN 16 // To set the minimum digital quantizing level to 16 LMAX, NBPC, DVQM Appendix A Command Reference LSPG Line Sync Pulse Gate Class Description Command syntax Format parameter settings Enables and disables the digital horizontal sync output. The LSPG? query returns the current LSPG mode. LSPG mode mode integer 0 = OFF 1 = ON Query syntax Query response Other required commands Example LSPG? 0 or 1 The FMTU command instructs the generator to use the new settings. The ALLU command updates the hardware to the new settings and redraws the test image. LSPG 1 FMTU Video Test Generator User Guide // Enable Line Sync // Update hardware to new settings 415 LSPP Line Sync Pulse Polarity Class Description Command syntax Format parameter setting - Synchronization Establishes the logic sense of the digital line sync output. Setting polarity to 1 causes the leading edge of line sync to be a low-to-high transition. Setting polarity to 0 causes the leading edge of line sync to be a high-to-low transition. The LSPP? query returns the current polarity of LSPP. LSPP polarity polarity 0 = active-low (negative going pulse) 1 = active-high (positive going pulse) Query syntax Query response Other required commands Example FSPP? 0 or 1 In order to get a pulse, line sync must first be enabled with the LSPG command. The FMTU command instructs the generator to use the new settings. The ALLU command updates the hardware to the new settings and redraws the test image. LSPG LSPP LSPW LSPG FMTU 416 1 1 20 300 // // // // // // Appendix A Command Reference Enable Line Sync Set for positive going pulse Make the pulse 20 pixels wide Pulse to occur 300 lines after the last line of active video Update hardware to new settings LUTA LUT save As Class Description Command syntax Lookup Table memory management Saves the current contents of the lookup table edit buffer using the given name. LUTA name name a valid MS-DOS filename (8 characters minus any extension) Example LUTA MY_LUT Video Test Generator User Guide // Save with the name "MY_LUT" 417 LUTB LUT editing Begin Class Description Command syntax Other required commands Example Lookup Table memory management Marks the beginning of a lookup table editing session. LUTB Use either an LUTL command to load an existing lookup table or an LUTN command to create a new lookup table. Use LUTE when ending the editing session. LUTN LUTB LUTE 418 // // // // // Initialize lookup table edit buffer Start lookup table editing session One or more lookup table editing commands ... End lookup table editing session Appendix A Command Reference LUTE LUT editing End Class Description Command syntax Other required commands Example Lookup table editor control Marks the end of a lookup table editing session. LUTE Use LUTB when starting the editing session. Use LUTA or LUTS to save changes. LUTB // Start lookup table editing session // One or more lookup table editing commands // ... LUTA My_LUT1 // Save edited lookup table as My_LUT1 LUTE // End lookup table editing session Video Test Generator User Guide 419 LUTK LUT Kill Class Description Command syntax Lookup table memory management Erases the named lookup table from memory. The LUTK? query checks to see if the named lookup table can be erased. The RAM location number is returned if it can be erased. Otherwise, a zero is returned. LUTK name name a valid MS-DOS filename (8 characters minus any extension) Query syntax LUTK? name name a valid MS-DOS filename (8 characters minus any extension) Query response Example 420 0 or location LUTK my_LUT1 Appendix A Command Reference // Erase lookup table called my_LUT1 LUTL LUTL LUT Load Class Description Command syntax Lookup table memory management Reads the lookup table having a name equal to name name from lookup table memory (or EPROM) into the lookup table. LUTL does not re-configure the signal generating hardware. This feature allows you to work on the contents of any lookup table memory location, while continuing to output a signal based on a previously-used lookup table (see LUTU command). The LUTL? query returns the location location in which a lookup table having a name equal to name is found. If multiple lookup tables exist having name name, then the lowest numbered location containing a lookup table with a matching name name is returned. The lookup table memory (RAM) is always searched first. If a lookup table with name name cannot be found anywhere in the lookup table memory, then the industry-standard lookup tables located in EPROM (negative locations) are searched next. LUTL? returns 0 if a lookup table with a name equal to name name cannot be found in either lookup table space. LUTL name name a valid MS-DOS filename (8 characters minus any extension) Query syntax Query response Other required commands Example LUTL? name location (returns 0 if not found) The LUTU command updates the hardware to the new settings. LUTL my_lut Video Test Generator User Guide // Load lookup table called my_lut 421 LUTN LUT New Class Description Command syntax Lookup table editor control Initializes the lookup table editing buffer and optionally sets the filename. LUTN name name (optional) valid MS-DOS filename (8 characters minus any extension) Other required commands Example 422 The LUTB command must be used to enable editing of the initialized buffer. LUTN my_lut2 LUTB Appendix A Command Reference // Create new edit buffer for my_lut2 // Begin editing LUTQ? LUT Query pointer Class Description Query syntax Lookup table memory management Returns number lookup table names from the list of all the lookup tables stored in lookup table memory beginning at index. The lookup tables are kept in alphanumeric order. LUTQ? index number index positive integer number number positive integer number Query response Examples: List of specified lookup table names. LUTQ? 1 5 // List the first five lookup tables in memory or LUTQ? 1 9999 Video Test Generator User Guide // List all lookup tables in memory 423 LUTS LUT Save Class Description Command syntax 424 Lookup table memory management Saves the current lookup table edit buffer contents into lookup table memory using the current name of the lookup table in the edit buffer. LUTS Appendix A Command Reference LUTU LUT Use Class Description Lookup table memory management Loads the lookup table hardware in accordance with the buffer contents. The LUTU? query returns either a lookup table memory location location or 0. If the lookup table currently in the hardware matches that originally loaded (using the LUTL command) from a lookup table memory location, then the matching lookup table memory location location is returned. Otherwise, if the hardware contents have changed since either an LUTR or LUTL command has been issued, then LUTU? query returns 0. Command syntax Query syntax Query response Example LUTU LUTU? location or 0 LUTU Video Test Generator User Guide // Update hardware to current buffer contents 425 MAPA bitMAP save As Class Description Command syntax Bitmap memory management Saves the current contents of the bitmap edit buffer using the given name. MAPA name name a valid MS-DOS filename (8 characters minus any extension) Example 426 MAPA MY_MAP // Save with the name "MY_MAP" Appendix A Command Reference MAPB bitMAP editing Begin Class Description Command syntax Other required commands Example Bitmap editor control Marks the beginning of a bitmap editing session. MAPB Use either an MAPL command to load an existing image or an MAPN command to create a new bitmap. Use MAPE when ending the editing session. MAPN MAPB // Initialize bitmap edit buffer // Start bitmap editing session // One or more bitmap editing commands ... MAPE Video Test Generator User Guide // End bitmap editing session 427 MAPE bitMAP editing End Class Description Command syntax Other required commands Example Bitmap editor control Marks the end of a bitmap editing session. MAPE Use MAPB when starting the editing session. Use MAPA or MAPS to save changes. MAPB // Start bitmap editing session // One or more bitmap editing commands ... MAPA My_map1 MAPE 428 Appendix A Command Reference // Save edited bitmap as My_map1 // End bitmap editing session MAPK bitMAP Kill from memory by name Class Description Command syntax Bitmap memory management Erases the named bitmap from memory. The MAPK? query checks to see if the named bitmap can be erased. The RAM location number is returned if it can be erased; otherwise, a 0 is returned. MAPK name name a valid MS-DOS filename (8 characters minus any extension) Query syntax MAPK? name name a valid MS-DOS filename (8 characters minus any extension) Query response Example 0 or location MAPK my_map1 Video Test Generator User Guide // Erase bitmap called my_map1 429 MAPL bitMAP Load from memory by name Class Description Command syntax Bitmap memory management Reads the bitmap having a name equal to name from bitmap memory into the bitmap buffer. MAPL does not change what is being displayed from the video memory. The MAPL? query returns the location location in which a bitmap having a name equal to name is found. If multiple bitmaps exist having name name, then the lowest numbered location containing a bitmap with a matching name name is returned. MAPL? returns 0 if a bitmap with a name equal to name cannot be found. MAPL name name a valid MS-DOS filename (8 characters minus any extension) Query syntax Query response Example 430 MAPL? name location (returns 0 if not found) MAPL SHAPE01 Appendix A Command Reference // Load bitmap called SHAPE01 into the buffer MAPN bitMAP New Class Description Command syntax Bitmap editor control Initializes the bitmap editing buffer. MAPN name name a valid MS-DOS filename (8 characters minus any extension) Example MAPN // Intialize bit-map buffer or MAPN Cool Video Test Generator User Guide // Initialize format buffer and name the format "Cool". 431 MAPQ? bitMAP Query pointer Class Description Query syntax Bitmap memory management Returns bitmap names from the list of all the bitmaps stored in bitmap memory beginning at index. The bitmaps are kept in alphanumeric order. The generator maintains internal variables for the current index and number values. The value of index is automatically incremented by number after the query is executed. Sending the query with just an index parameter returns the same number of names as the last time, starting at the given index. Sending the query with no parameters returns the next set of names. MAPQ? index number index positive integer number number positive integer number Query response Example List of specified bitmap names. MAPQ? 1 9999 // List all bitmaps in memory or MAPQ? 1 10 MAPQ? 21 MAPQ? 432 Appendix A Command Reference // List the first ten bitmaps in memory // List the 21st through the 30th MAPes in memory // List the 31st through the 40th MAPes in memory MAPS bitMAP Save Class Description Command syntax Bitmap memory management Saves the current bitmap edit buffer contents into bitmap memory using the current name of the bitmap in the edit buffer. MAPS Video Test Generator User Guide 433 MEMC MEMory Compact Class Description Command syntax Example Related commands 434 MEM Consolidates free memory into contiguous blocks. MEMC?Is this a command or query. If query, what is the response? MEMC // Compact the system memory MEMF?, MEML? Appendix A Command Reference MEMF? MEMory Free Class Description MEM Returns the number of free blocks in managed memory. Query syntax MEMF? Example MEML? 818088 Related commands // to determine the amount of free memory block // lists the number of contiguous free memory blocks MEMC, MEML? Video Test Generator User Guide 435 MEML? MEMory Largest free Class Description Returns the largest free contiguous block in managed memory. Query syntax MEML? Example MEML? 816568 Related commands 436 MEM // to determine the largest contiguous block of free memory // lists the amount of contiguous free memory MEMC, MEMF? Appendix A Command Reference MEMT MEMory Test Class Description Command syntax Query syntax Query response MEM Runs a memory manager test to detect corruption or inconsistencies. The MEMT? query returns the results of the most recent run of the memory manager test command. MEMT MEMT? 0 or 1 0 = no memory corruptions or inconsistencies were discovered 1 = a memory corruption or inconsistency was found Example Related commands MEMT MEML? // to run the memory manager test // to view the results of the memory manager test MEMC, MEMF? Video Test Generator User Guide 437 MMAP Move a rectangular bitMAP area Class Description Command syntax Video Frame Buffer manipulation Copies a rectangular area of pixels from one location of the video frame buffer to another. The size of the area, in pixels, is defined by the width and height parameters. The top left corner of the source location is specified by xs, ys pixel coordinates. The top left corner of the destination location is specified by the xd, yd pixel coordinates. MMAP width height xs ys xd yd width, height size of the area, in pixels xs, ys top left corner of the source location xd, yd top left corner of the destination location Query syntax Example 438 MMAP? MMAP 40 30 0 0 50 50 Appendix A Command Reference // // // // Copies a 40 pixel wide by 30 pixel high area in the top left corner of active video to an area 50 pixel below and to the right of the top left corner. MODE communications MODE Class Description Command syntax System parameter settings Sets the serial port communications parameters of a stand-alone model generator. The changes take effect as soon as the command is entered. The factory default settings are 2400 baud, no parity, 8 data bits, no stop bits, no handshake, and no protocol. MODE baud parity data stop handshake protocol baud rate 300, 600, 1200, 2400, 4800, 9600, 19200, 38400, 57600, or 115200 bits/sec parity N = None, E = Even or O = Odd data number of data bits: 7 or 8 stop number of stop bits: 1 or 2 handshake N = None H = Hardware (CTS/RTS) protocol N = None Y=Y-Modem Example MODE 9600 N 8 1 H N // Set a stand alone generator to // communicate at 9600 Baud, No parity, 8 data bits, // 1 stop bit, RTS//CTS handshaking and No protocol or MODE 2400 Video Test Generator User Guide // Change only the baud rate 439 MSIZ light Meter SIZe Class Description Command syntax System parameter settings Establishes the physical size of the light meter boxes displayed in the BriteBox test image. The unit of measure used is based on the current setting of the system level USIZ command. It also affects the size of the cursor boxes in the Persist image. Changing the size will not change the currently displayed image. The MSIZ? query returns the current settings of MSIZ based on the current setting of the system level USIZ command. MSIZ width height or MSIZ common_size size positive floating point number common_size square box Query syntax Query response Other required commands Example 440 MSIZ? width, height The correct unit of measure should be selected with the USIZ command prior to setting the size. USIZ 1 MSIZ 2.0 IMGL BriteBox IMGU Appendix A Command Reference // // // // Select inches for units Set size to 2.0 inches Select BriteBox image Draw selected image using new size MUTE Audio/Video Mute Class Description Command syntax Sonic data generator Enables and disables the HDMI Audio/Video Mute (AVMUTE) feature. When enabled, audio and video are muted by the generator. MUTE flag flag 0 = disable (AVMUTE_clear_flag sent repeatedly) 1 = enable (AVMUTE_set_flag sent repeatedly) Query syntax Query response MUTE? 0 or 1 Related commands Example To enable AVMUTE: MUTE 1 MUTE? Use the MUTE? to continuously check until the AVMUTE state is changed (may not take place right away). Video Test Generator User Guide 441 NAMF? NAMe Find Class Description Query syntax Directory editor control Returns the index number of the entry with name name in the directory edit buffer. The first name in the buffer has an index value of 1. If name is not found, a value of 0 is returned. NAMF? name name a valid MS-DOS filename (8 characters minus any extension) Query response Example 442 index NAMF? VGA_m4 Appendix A Command Reference // Return position of VGA_m4 in directory NAMI NAMe Insert Class Description Command syntax Directory editor control Moves all the names with index values equal to or greater than index to the next higher index value in the directory edit buffer, and then inserts the name name in the directory edit buffer at position index. A negative number or a 0 used for index will put name at index position 1. Using a number for index beyond the last name in the buffer will add name to the index position just beyond the last name. The command does not check if a file called name is stored in the generator. NAMI index name name a valid MS-DOS filename (8 characters minus any extension) Example 1 This example inserts the DMT0660A format on the knob list at location 1: DIRL FMT DIRB NAMI 1 DMT0660A DIRE DIRS Example 2 NAMI 5 FOCUS1 Example 3 NAMI -6 BARS Example 4 NAMI 999999 HATCH Video Test Generator User Guide // Put FOCUS1 in fifth position // Put BARS at beginning of dir // Put HATCH at end of dir 443 NAMK NAMe Kill Class Description Command syntax Directory editor control Deletes the given name from the directory edit buffer. All names with index values greater than the index of the deleted name are moved to the next lower index value in the buffer. Nothing happens if name is not found in the buffer. NAMK name name a valid MS-DOS filename (8 characters minus any extension) Example 444 NAMK VGA_m4 // Remove VGA_m4 from dir Appendix A Command Reference NAMQ? NAMe Query Class Description Query syntax Directory editor control Returns number names from the list of names in the directory edit buffer beginning at index. The generator maintains internal variables for the current index and number values. The value of index is automatically incremented by number after the query is executed. Sending the query with just an index parameter, will return the same number of names as the last time, starting at the given index. Sending the query with no parameters will return the next set of names in the directory buffer. NAMQ? index number index positive integer number number positive integer number Query response List of specified entry names from directory edit buffer. Example 1 NAMQ? 1 9999 Example 2 NAMQ? 1 10 NAMQ? 21 NAMQ? Video Test Generator User Guide // List the entire buffer // List the first ten names in the buffer // List the 21st through the 30th names in the buffer // List the 31st through the 40th names in the buffer 445 NAMY NAMe Yank Class Description Command syntax Example 446 Directory editor control Deletes the name at the given index number from the directory edit buffer. All names with index values greater than the index of the deleted name are moved to the next lower index value in the buffer. Nothing happens if index is beyond the index number of last name in the buffer. NAMY index NAMY 2 // Remove second item from dir Appendix A Command Reference NBPA Number Bits Per Audio sample Class Description Command syntax Format parameter setting - Audio signal Sets the number of bits per audio sample for an audio signal. This sets the SS parameter of the Audio InfoFrame (as specified in EIA/CEA-861-B, table 20). NBPA bits bits 0 (let incoming external audio stream determine the number of bits per sample) 16 Example Related commands NBPA 16 IFGU XAUD (SS parameter), SAMP Video Test Generator User Guide 447 NBPC Number Bits Per Component Class Description Command syntax Format parameter setting - Digital video signal Sets the number of bits per color component (color depth). NBPC bits bits 6, 8, 10, or 12 depending on output. Example Related commands 448 Output NBPC DVI 8 TV 12 LVDS 6 (18-bit encoding) or 8 (24-bit encoding) HDMI Digital RGB or YCbCr 4:4:4 output 8 HDMI YCbCr 4:2:2 output 8, 10, or 12. NBPC 10 FMTU DVSM, DVQM Appendix A Command Reference NCPP Number Clocks Per Pixel Class Description Format parameter setting - Digital video signal Specifies the number of clocks per pixel (double-clocking factor for whole line). Some industry standard formats (e.g. 480i) have pixel rates that are below the minimum pixel rate restriction (of 25 MHz) required by the TMDS interface. In these cases, a feature known as “double-clocking” is used to raise the TMDS clock rate to an acceptable frequency. Double-clocking is controlled by the NCPP format parameter. When NCPP is set to 1 (normal single-clocked), each pixel, output by the generator, is paired with one clock pulse. In this case, the pixel rate is equal to the TMDS clock rate. By setting NCPP to 2 (double-clocked), two clocks are send during each pixel period and the TMDS clock rate is raised to 2 times the pixel rate. Note that double clocking with NCPP and pixel repetition (NPPP) cannot be applied at the same time. Command syntax NCPP factor factor 1 or 2 Related commands Example NBPA, NPPP NCPP 2 FMTU Video Test Generator User Guide 449 NDAC Number Digital Audio Channels Class Description Format parameter setting - Audio signal Sets the number of digital audio channels for an audio signal. This sets the CC parameter of the Audio InfoFrame (as specified in EIA/CEA-861-B, table 20). Note: Currently, only two audio channels are supported. Command syntax NDAC channels channels 2 Example Related Commands 450 NDAC 2 IFGU XAUD (CC parameter) Appendix A Command Reference NDAS Number Digital Audio Streams Class Description Format parameter setting - Audio signal Sets the number of digital audio streams. Note: Currently, only one audio stream is supported. Command syntax NDAS streams streams 1 (default) Example NDAS 1 IFGU Video Test Generator User Guide 451 NERR? Number of ERRors in queue Class Description Query syntax Query response 452 System memory management Returns the number of errors waiting to be reported in the error queue. NERR? number of errors Appendix A Command Reference NLNK Number of digital LiNKs Class Description Command syntax Format parameter setting - Digital video signal Determines the number of links used by the LVDI digital outputs on generators that support LVDI outputs. The NLNK? query returns the current setting of NLNK. NLNK links links integer 0 = Default, let the generator decide 1 = Single link 2 = Dual link Query syntax Query response Other required commands Example NLNK? links The FMTU command instructs the generator to use the new setting. The ALLU command updates hardware to the new setting and redraws the test image. NLNK 2; FMTU Video Test Generator User Guide 453 NOGA use NO GAmma correction Class Description Command syntax 454 Custom image primitive Temporarily disables any gamma correction that may be selected in a format. All color intensity levels in all parts of the custom image are output without gamma correction. Gamma correction is disabled only for as long as the image is displayed. NOGA Appendix A Command Reference NOTU NOT Until communication is complete Class Description Command syntax Query syntax Query response System Level Temporarily holds-off any ongoing command execution until communication is complete and ALLU is invoked. NOTU NOTU? 0 if not enabled non-zero when enabled Other required commands Disabled by ALLU. Video Test Generator User Guide 455 NPPP Number Pixels Per Pixel Class Description Command syntax Format parameter setting - Digital video signal Specifies repetition factor for active portion of line. NPPP factor factor 0 to disable repetition mode (removes extra left and right repetition bars) 1 to 10 enables pixel repetition mode (inserts extra left and right repetition bars) Related commands Example 456 NCPP NPPP 4; FMTU Appendix A Command Reference NSTP? Number of STePs in sequence Class Description Query syntax Query response Sequence editor control Returns the number of steps in a sequence in the buffer. NSTP? steps Video Test Generator User Guide 457 OERR? ERRor queue Overflow Class Description Query syntax Query response System memory management Checks for overflow in the error queue. Overflow occurs when an attempt is made to add more errors to the queue than it can hold. OERR? overflow status 0 = No Overflow 1 = Overflow 458 Appendix A Command Reference OFFX image OFFset X Class Description Command syntax Image editor control Sets the horizontal offset used for the large patch in the Regulate test image. It may also control other images. The OFFX? query returns the current OFFX setting. OFFX x_offset x_offset integer number of pixels Query syntax OFFX? Query response X offset Example OFFX 20 Video Test Generator User Guide 459 OFFY image OFFsetY Class Description Command syntax Image editor control Sets the vertical offset used for the large patch in the Regulate test image. It may also control other images. The OFFY? query returns the current OFFY setting. OFFY y_offset y_offset integer number of pixels Query syntax OFFY? Query response Y offset Example 460 OFFY 20 Appendix A Command Reference OUTG OUTputs Gate Class Description Command syntax System parameter settings Gates all video and sync outputs of the generator ON and OFF. Gating the outputs OFF forces all outputs to be turned off. Gating the outputs ON turns on all outputs whose individual gating settings are turned ON. The OUTG? query returns the current status of the outputs of the generator. OUTG mode mode 0 = OFF 1 = ON Query syntax Query response Example OUTG? mode OUTG 0 ALLU Video Test Generator User Guide 461 OVAL draw an OVAL Class Description Custom image primitive Draws an oval whose axes are parallel to the vertical and horizontal axes of displayed video. The size and position of the oval are defined by its framing rectangle. The framing rectangle is a rectangle whose sides are both tangent to the oval at four points and are parallel to the vertical and horizontal axis of video. It is not drawn as part of the primitive. The figure below shows the relationship of an oval to its framing rectangle. height left, top width OVAL uses six parameters. The first is color. The next two are the pixel width and height of the framing rectangle in pixels. The fourth and fifth parameters are the x, y coordinates for the top left corner of the framing rectangle. The last parameter is the fill. Command syntax OVAL color width height x y fill color available colors width total number of horizontal pixels height total number of lines x, y positive integer numbers fill available fill patterns Other required commands Example 462 The FMTU command instructs the generator to use the new setting. The ALLU command updates hardware to the new setting and redraws the test image. OVAL red 240 150 20 10 GrayPat0 Appendix A Command Reference // // // // Draw a red oval 240 pixels wide by 150 pixels high. Start framing rectangle at X=20, Y=10. Fill = none PAGE draw PAGE of repeating characters Class Description Command syntax Custom image primitive Fills a rectangular area (page or block) with a character that repeats horizontally and vertically. The color parameter sets the color used to draw the character. The width and height parameters determine the size of the block to be filled. The x and y parameters determine the top left corner of the block. The font parameter selects which font is used to draw the character. The character parameter selects a specific character (by number). For full alphanumeric fonts, the character number is the same as the character's ASCII code number. The spacing between the characters is fixed by the character block size in the font and cannot be changed. Partial characters are not drawn to completely fill the rectangular area; rather, the largest possible block of full characters is centered in the rectangular area. PAGE color width height x y font character color available colors width width of page in pixels height height of page in lines x position of left edge of page in pixels y position of top edge of page in pixels font available fonts character min = 0 max = 255 Example PAGE blue 40 30 10 10 opix9 69 // Draw a small block of blue E characters in the upper left corner Video Test Generator User Guide 463 PCPG Pixel Clock Pulse Gate Class Description Command syntax Format parameter settings Enables and disables the pixel clock pulse output on generators that have a pixel clock output available. The PCPG? query returns the current setting of PCPG. PCPG mode mode 0 = OFF 1 = ON Query syntax Query response Other required commands Example 464 PCPG? mode FMTU or ALLU PCPG 1 FMTU // Enable pixel clk output in buffer // Update hardware with format data Appendix A Command Reference PDAU Pixel Data Analyzer Use Class Description Command syntax Example Related commands Signal analyzer - Pixel data Loads the hardware required and copies the patch (static image) from the DVI source to memory. This command is used for the Delta Error Patch test. PDAU PDAU //copies patch from external source to generator memory GPEL? Video Test Generator User Guide 465 PDSH Pixel Data Signal Height Class Description Signal analyzer - Pixel data Sets the height of the patch of pixel data to be analyzed. Note: The maximum area (width multiplied by height) of the patch is 1024 pixels. Command syntax PDSH height height pixel height of patch Query syntax Query response Example Related commands 466 PDSH? pixel height of patch PDSX 128 PDSY 256 PDSH 64 PDSW 96 PDAU GPEL? 128 256 0,255,0 //sets patch starting at x-pixel 128 //sets patch starting at y-pixel 256 //sets patch height at 64 pixels //sets patch width at 90 pixels //captures patch of image //read RGB color components at pixel address 128,256 PDSW, PDSX, PDSY, PDAU Appendix A Command Reference PDSW Pixel Data Signal Width Class Description Signal analyzer - Pixel data Sets the width of the patch of pixel data to be analyzed. Note: The maximum area (width multiplied by height) of the patch is 1024 pixels. Command syntax PDSW width width pixel width of patch Query syntax Query response Example Related commands PDSW? pixel width of patch PDSX 128 PDSY 256 PDSH 64 PDSW 96 PDAU GPEL? 128 256 0,255,0 //sets patch starting at x-pixel 128 //sets patch starting at y-pixel 256 //sets patch height at 64 pixels //sets patch width at 90 pixels //captures patch of image //read RGB color components at pixel address 128,256 PDSH, PDSX, PDSY, PDAU Video Test Generator User Guide 467 PDSX Pixel Data Signal X Location Class Description Command syntax Signal analyzer - Pixel data Controls the x location of the patch data to be analyzed. PDSX x x x-coordinate number for patch Query syntax Query response Example Related commands 468 PDSX? x-coordinate number PDSX 128 PDSY 256 PDSH 64 PDSW 96 PDAU GPEL? 128 256 0,255,0 //sets patch starting at x-pixel 128 //sets patch starting at y-pixel 256 //sets patch height at 64 pixels //sets patch width at 90 pixels //captures patch of image //read RGB color components at pixel address 128,256 PDSY, PDSW, PDSH, PDAU Appendix A Command Reference PDSY Pixel Data Signal Y Location Class Description Command syntax Signal analyzer - Pixel data Controls the y location of the patch data to be analyzed. PDSY y y y-coordinate number for patch Query syntax Query response Example Related commands PDSY? y-coordinate number PDSX 128 PDSY 256 PDSH 64 PDSW 96 PDAU GPEL? 128 256 0,255,0 //sets patch starting at x-pixel 128 //sets patch starting at y-pixel 256 //sets patch height at 64 pixels //sets patch width at 90 pixels //captures patch of image //read RGB color components at pixel address 128,256 PDSX, PDSW, PDSH, PDAU Video Test Generator User Guide 469 PELD PixEL Depth Class Description Command syntax Format parameter settings Establishes the number of data bits that represent each active pixel in video memory (frame buffer). The PELD? query returns the current setting of PELD. PELD depth depth integer 0 = use generator default 4 = 4 bits-per-pixel (16 colors) 8 = 8 bits-per-pixel (256 colors) 32 = 24 bits-per-pixel (16,777,216 colors) Query syntax Query response Other required commands Example 470 PELD? depth The FMTU command instructs the generator to use the new setting. The ALLU command updates hardware to the new setting and redraws the test image. PELD 8 ALLU // Select 8 bits-per pixel // Configure hardware and redraw image Appendix A Command Reference PENH PEN Height Class Description Command syntax Image editor control Sets a variable used establish line thicknesses to draw EeRise, NAWC, and Slider test images. PENH height height integer Query syntax Query response Example PENH? height PENH 4 Video Test Generator User Guide 471 PENW PEN Width Class Description Command syntax Image editor control Sets a variable used to establish line thicknesses to draw EeRise, NAWC and Slider test images. PENW width width integer Query syntax Query response Example 472 PENW? width PENW 4 Appendix A Command Reference PKUP PacKUP operation related to DMA Class Description Command syntax System Level Prepares files for transmission when using the YMDO archiving command PKUP Video Test Generator User Guide 473 PNAU Measure Pseudo Noise Class Description Command syntax Example Signal Analyzer - Pseudo-random noise Loads the hardware required to generate the pseudo noise and measures all the related required parameters. PNAU PNSF PNST PNSA PNSM PNSP PNAU 0 1 1 0 0 //Pseudo-random //Pseudo-random //Pseudo-random //Pseudo-random //Pseudo-random //Pseudo-random noise noise noise noise noise noise signal format set to CURRENT (internal) signal type set to QDI-BCM signal advance set to ACTIVE PIXELS signal mode set to AUTO signal procedure set to CONTINUOUS generated CR //Stop pseudo-random noise GPER? 0.88 //Returns the pixel error rate (in errors per billion) GNPT? 4.255 //Returns the number of pixels measured (in billions) GCET? //Returns the total number of errors detected on the red, green, and blue components along with the total number of bad pixels 0,21,0,21 GFED? //Returns data related to any error (first error only) 40018C,FFFFFF Related commands 474 GPER?, GNPT?, GCET?, GFED? Appendix A Command Reference PNGU Pseudo Noise Generator Use Class Description Command syntax Signal Analyzer - Pseudo-random noise Loads the hardware required to generate pseudo-random noise (per the latest pseudo-random noise signal settings). PNGU Example 1 PNSF PNST PNSA PNSM PNSP PNSG PNGU 1 1 1 0 0 1 //Pseudo-random noise signal //Pseudo-random noise signal //Pseudo-random noise signal //Pseudo-random noise signal //Pseudo-random noise signal //Pseudo-random noise signal //Output Pseudo-random noise Example 2 To stop pseudo-random noise output: format set to CURRENT (internal) type set to QDI-BCM advance set to ACTIVE PIXELS mode set to AUTO procedure set to CONTINUOUS gate set to ON using latest parameters PNSG 0 //Pseudo-random noise signal gate set to OFF PNGU Related commands PNSG Video Test Generator User Guide 475 PNSA Pseudo Noise Signal Advance Class Description Command syntax Signal Analyzer - Pseudo-random noise Controls how often pseudo-random noise pixels are calculated. PSNA value value 0 = every pixel clock 1 = every active pixel clock Query syntax Query response Example Related commands 476 PNSA? 0 or 1 PNSA 1 //Set calculation to pixel every clock PNGU PNGU Appendix A Command Reference PNSF Pseudo Noise Signal Format Class Description Command syntax Signal Analyzer - Pseudo-random noise Selects the source of timing information used by the various pseudo-random noise parameters. PNSF source source 0 = CURRENT (timing parameters are based on the internally-generated DVI signal) 1 = MEASURED (timing parameters are based on a measurement of the DVI signal received at the DVI Input connector from an external signal source) Query syntax Query response Example Related commands PNSF? 0 or 1 PNSF 0 // timing parameters are based on internal DVI signal PNGU PNGU Video Test Generator User Guide 477 PNSG Pseudo Noise Signal Gate Class Description Command syntax Signal Analyzer - Pseudo-random noise Gates on or off the output of pseudo-random noise. PNSG gate gate 0 = Pseudo-random noise is not output (the selected image is output) 1 = Pseudo-random noise is output (replacing the selected image output) Query syntax Query response Example Related commands 478 PNSG? 0 or 1 PNSG 1 //Output pseudo-random noise from the generator PNGU PNGU Appendix A Command Reference PNSL Pseudo Noise Signal Length Class Description Command syntax Signal Analyzer - Pseudo-random noise Sets the run-length value of the pseudo-random noise sequence. PNSL length length hexidecimal number Query syntax Query response Example Related commands PNSL? run-length value PNSL 4AFFF //set the pseudo-random noise sequence run-length PNGU PNSS, PNGU Video Test Generator User Guide 479 PNSM Pseudo Noise Signal Mode Class Description Command syntax Signal Analyzer - Pseudo-random noise Determines how the pseudo-random noise sequence seed and run-length are determined. PNSM mode mode 0 = Auto mode. The sequence seed and run-length parameters are set automatically. The seed is automatically set to 0x08000001. Noise values are advanced according to the current setting of the PNSA parameter. If PNSA is set to 0 (every pixel), the sequence length is automatically set to the total number of pixels (per frame) minus one. Alternately, if PNSA is set to 1, noise is advanced every active pixel, and the length is set to the size of the HRES*VRES active area (per frame) minus one. 1 = Manual mode. The sequence seed and run-length must be manually set using the PNSL and the PNSS commands. Query syntax Query response Example Related commands 480 PNSM? 0 or 1 PNSM 0 //set pseudo-random noise seed and run-length values automatically PNGU PNGU Appendix A Command Reference PNSP Pseudo Noise Signal Procedure Class Description Signal Analyzer - Pseudo-random noise Selects the procedure used when making pseudo-random noise measurements. PNSP procedure procedure 0 = CONTINUOUS (stop after key press, knob turn, or any I/O). In this mode, noise testing continues until either a key-press, a knob-turn, or serial/GPIB/host I/O port activity is detected. To stop the CONTINUOUS mode remotely via the I/O ports, a “\r” is recommended. 1 = SINGLE SHOT (stop after one run-length). In this mode, a single run-length is executed before the pseudo-random noise measurement is stopped. n = MULTI SHOT (stop after n run-length shots). In this mode, a number of run-lengths (n) are executed before pseudo-random noise measurement is stopped and results become available. Query syntax Query response Example Related commands PNSP? 0-2 PNSP 23 // run 23 sequences of the pseudo-random noise measurement PNGU PNGU Video Test Generator User Guide 481 PNSS Pseudo-Noise Signal Seed Class Description Command syntax Signal Analyzer - Pseudo-random noise Sets the seed value of the pseudo-random noise sequence. A seed value represents a specific pseudo-random noise sequence. PNSS seed seed hexidecimal number Query syntax Query response Example Related commands 482 PNSS? seed value PNSS 8000001 //set pseudo-random noise seed value PNGU PNSL, PNGU Appendix A Command Reference PNST Pseudo Noise Signal Type Class Description Command syntax Signal Analyzer - Pseudo-random noise Selects the pseudo-random noise algorithm to be used. PNST algorithm algorithm 0 = T & M algorithm (not supported) 1 = QDI-BCM algorithm Query syntax Query response Example Related commands PNST? 0 or 1 PNST 1 //set QDI-BCM algorithm for pseudo-random noise PNGU PNGU Video Test Generator User Guide 483 PRAT? Pixel RATe query Class Description Query syntax Query response Example Format parameter setting - Video resolution Returns the current pixel rate setting. PRAT? pixel rate PRAT? +25.1752E+06 Related commands 484 TMAU Appendix A Command Reference PREG PRE-emphasis Gate Class Description Command syntax Format parameter settings Enables and disables adding pre-emphasis to the Open LVDI digital outputs on generators that support LVDI outputs. The PREG? query returns the current setting of PREG. Pre-emphasis is used to add compensation for signal loss in long cables. PREG mode mode 0 = Pre-emphasis OFF 1 = Pre-emphasis ON Query syntax Query response Other required commands PREG? mode FMTU or ALLU Video Test Generator User Guide 485 PSHD Probe Sync Pulse Horizontal Delay Class Description Command syntax Special Sync Probe Pulse Sets the delay (in pixels) of the line(s) on which the probe pulse occurs on the special sync output. The PSHD? query returns the current PSHD value. PSHD width width integer 0=PSVD(HTOT - PSPW-1) Query syntax Query response Other required commands Related commands Example 486 PSHD? width The FMTU command instructs the generator to use the new settings. The ALLU command updates the hardware to the new settings and redraws the test image. PSPG, PSPW, PSPP, PSVD, PSPM PSPG PSPP PSPW PSHD PSVD ALLU 1 1 10 200 300 // // // // // // Appendix A Command Reference Enables probe pulse on special sync Sets probe pulse polarity to positive Sets probe pulse width to 10 pixels Sets probe pulse horizontal delay to 200 pixels Sets probe pulse vertical delay to 300 pixels Applies the settings PSPG Probe Sync Pulse Gate Class Description Command syntax Special Sync Probe Pulse Enables and disables the probe pulse on the special sync output. The PSPG? query returns the current PSPG mode. PSPD mode mode integer 0 = OFF 1 = ON Query syntax Query response Other required commands Related commands Example PSPG? 0 or 1 The FMTU command instructs the generator to use the new settings. The ALLU command updates the hardware to the new settings and redraws the test image. PSPP, PSPW, PSHD, PSVD, PSPM FSPG 0 PSPG 1 ALLU Video Test Generator User Guide // Disables frame sync // Enables probe pulse on special sync // Applies the settings 487 PSPM Probe Sync Pulse Mode Class Description Command syntax Special Sync Probe Pulse Determines what lines in the frame or field the probe pulse occurs on the special sync output. The PSPM? query returns the current PSPM value. PSPM mode mode integer 0 = once per frame 1 = every active line in frame 3 = every line in frame Query syntax Query response Other required commands Related commands Example 488 PSPM? 0, 1, or 3 The FMTU command instructs the generator to use the new settings. The ALLU command updates the hardware to the new settings and redraws the test image. PSPG, PSPP, PSPW, PSHD, PSVD PSPG PSPP PSPW PSHD PSVD PSPM ALLU 1 1 10 200 300 1 // // // // // // // Appendix A Command Reference Enables probe pulse on special sync Sets probe pulse polarity to positive Sets probe pulse width to 10 pixels Sets probe pulse horizontal delay to 200 pixels Sets probe pulse vertical delay to 300 pixels Sets probe pulse to occur on each active line in a frame Applies the settings PSPP Probe Sync Pulse Polarity Class Description Command syntax Special Sync Probe Pulse Sets the polarity of the probe pulse on the special sync output. The PSPG? query returns the current PSPP value. PSPP polarity polarity integer 0 = negative 1 = positive Query syntax Query response Other required commands Related commands Example PSPP? 0 or 1 The FMTU command instructs the generator to use the new settings. The ALLU command updates the hardware to the new settings and redraws the test image. PSPG, PSPW, PSHD, PSVD, PSPM PSPG 1 PSPP 1 ALLU Video Test Generator User Guide // Enables probe pulse on special sync // Sets probe pulse polarity to positive // Applies the settings 489 PSPW Probe Sync Pulse Width Class Description Command syntax Special Sync Probe Pulse Sets the width in pixels of the probe pulse on the special sync output. The PSPW? query returns the current PSPW value. PSPW width width integer 1 pixel to (HTOT - 1)) Query syntax Query response Other required commands Related commands Example 490 PSPW? width The FMTU command instructs the generator to use the new settings. The ALLU command updates the hardware to the new settings and redraws the test image. PSPG, PSPP, PSHD, PSVD, PSPM PSPG 1 PSPP 1 PSPW 100 ALLU // // // // Appendix A Command Reference Enables probe pulse on special sync Sets probe pulse polarity to positive Sets probe pulse width to 100 pixels Applies the settings PSVD Probe Sync Pulse Vertical Delay Class Description Command syntax Special Sync Probe Pulse Sets the line in the frame or field that the probe pulse occurs on the special sync output. The PSVD? query returns the current PSVD value. PSVD line line integer 0 = PSVD(VTOT-1) Query syntax Query response Other required commands Related commands Example PSVD? line The FMTU command instructs the generator to use the new settings. The ALLU command updates the hardware to the new settings and redraws the test image. PSPG, PSPW, PSPP, PSHD, PSPM PSPG PSPP PSPW PSVD ALLU 1 1 10 300 Video Test Generator User Guide // // // // // Enables probe pulse on special sync Sets probe pulse polarity to positive Sets probe pulse width to 10 pixels Sets probe pulse vertical delay to 300 pixels Applies the settings 491 PUTA PUT Absolute Class Description Direct processor control Writes the specified value value into memory at the specified address address. The two parameters address and value are interpreted according to the current setting of BASE (see the BASE command). The number and format of the bits written depend on the current setting of SIZE (see the SIZE command). Note: This command is used only with custom applications and command files created by Quantum Data. Indiscriminate use of this command can cause the generator to stop operating and the loss of stored data in non-volatile RAM. Command syntax PUTA address value address 0 to 4,294,967,295 unsigned decimal (BASE = 10) -2,147,483,648 to 2,147,483,647 (BASE = -10) 0 to FFFFFFFF (BASE = 16) -80000000 to 7FFFFFFF (BASE = -16) value 0 to 2^(SIZE)-1 Other required commands 492 PUTA expects parameters formatted according to the current radix set by the BASE command. Appendix A Command Reference PUTR PUT Relative Class Description Direct processor control Writes the specified value value into the location pointed to by the address register (see the ADDR command). The parameter value is interpreted according to the current setting of BASE (see the BASE command). The number and format of the bits written depend on the current setting of SIZE (see the SIZE command). The address register is automatically incremented by SIZE bits after the current location has been written to. Note: This command is used only with custom applications and command files created by Quantum Data. Indiscriminate use of this command can cause the generator to stop operating and the loss of stored data in non-volatile RAM. Command syntax PUTR value value 0 to (2^(SIZE))-1 Other required commands PUTR expects parameters formatted according to the current radix set by the BASE command. Video Test Generator User Guide 493 PXAR? Pixel Aspect Ratio Query Class Description Query syntax Query response Related commands Example 494 Format parameter setting - HDMI active video Reads the aspect ratio of pixels in active regions of the raster image. PXAR? aspect ratio NCPP PXAR? +1.00000E+00 Appendix A Command Reference RATC pixel RATe Calibration factor Class Description System parameter settings Sets an internal multiplication factor used in setting the pixel clock frequency. The multiplication factor can be set to compensate for the frequency error of the internal reference crystal. Having to use a factor outside of the typical range may indicate a failure of generator's hardware. Reinitializing the generator's memory sets the calibration factor to a factory-default setting of 1.00000. Note: The RATC parameter is a system level parameter that will affect the pixel clock frequency of all formats that are recalled. The RATC value will be retained when the generator is powered down and back up again. Query the current setting of RATC if you are experiencing problems with the pixel clock or scan rate being off in frequency. Command syntax RATC factor factor floating point number equal to calibration factor typical min = 0.99990 typical max = 1.00010 Query syntax Query response Example RATC? factor RATC 1.00007 Video Test Generator User Guide // Increases pix clk by factor of 1.00007 495 RCTL Reset masked ConTroL bits Class Description Format parameter setting - Digital video signal Resets the masked control bits for the Broadcom or Silicon Image chip to low. The bits to be reset are (one byte mapped as follows): CTL13 CTL12 CTL11 CTL10 CTL03 CTL02 CTL01 CTL00 To reset a specific control bit, the mask must account for the current setting of the remaining bits. See example below. Note: CTL03 is not part of this resetting. It controls the HDCP. Command syntax RCTL mask mask hexidecimal Example Related commands 496 SCTL 23 RCTL 22 // sets CTL00, CTL01, CTL11 to high // resets CTL00 bit to low (0) SCTL Appendix A Command Reference RECT draw a RECTangle Class Description Command syntax Custom image primitive Draws a rectangle whose sides are parallel to the vertical and horizontal axes of displayed video. It uses six parameters. The first is the color of the line. The next two parameters are the pixel width and height of the rectangle. The fourth and fifth parameters are the x and y coordinates for the top left corner of the rectangle. The last parameter is the fill. RECT color width height x y fill color available colors width total number of horizontal pixels height total number of lines x, y positive integer numbers fill available fill patterns Other required commands Example The FMTU command instructs the generator to use the new setting. The ALLU command updates hardware to the new setting and redraws the test image. RECT gray50 15 20 50 40 GrayPat50 // Draw a 50% gray rectangle 15 pixels wide and 20 pixels high // with top left corner at X=50, Y=40 Fill with 50% active pixels ALLU Video Test Generator User Guide // Update hardware to current buffer contents 497 REDG RED Gate Class Description Command syntax Video Gate Toggles the red video signal gate. REDG mode mode 0 = disable 1 = enable Query syntax Query response Other required commands REDG? 0 or 1 ALLU to invoke the command. Related commands BLUG, GRNG Example REDG 0; ALLU 498 Appendix A Command Reference // disable red video component RFLD Repeat FieLD Class Description Command syntax Format parameter setting - Video resolution Determines if identical video information is output for each field of an interlaced (SCAN = 2) format. The RFLD? query returns the current setting of RFLD. RFLD mode mode 0 = disabled 1 = enabled Query syntax Query response Other required commands Example RFLD? 0 or 1 FMTU or ALLU SCAN 2 RFLD 1 FMTU Video Test Generator User Guide // Set Interlaced scanning // Enable repeat field buffer // Update hardware with format data 499 RGBQ? RGB lut Query Class Description Query syntax LUT Management Returns the current lookup table buffer contents when a lookup table editing session is active (between LUTB and LUTE) and returns the actual lookup table values in the hardware LUT when a lookup table editing session is not active (between LUTE and LUTB). RGBQ? first_slot slots_returned first_slot first slot number slots_returned number of slots to be returned Query response Example 500 slot_number red_level green_level blue_level crlf LUTB;RGBQ? 0 16 Appendix A Command Reference RGBW RGB Write Class Description Command syntax LUT Management Writes RGB levels to the slot location specified within the current lookup table buffer when a lookup table editing session is active, and writes the levels directly to the LUT hardware when a lookup table editing session is not active. RGBW slot red_level green_level blue_level slot integer 0 to 15 when PELD = 4 0 to 255 when PELD = 8 red_level, green_level, blue_level integer min = 0 max = LMAX setting (255 nominal) Related commands Example RGBQ? LUTE;RGBW 1 255 128 0 Video Test Generator User Guide // Set slot 1 to an orange color 501 RMAP Render MAP Class Description Command syntax Bitmap image control Renders a map (icon) at the user-specified coordinates. RMAP x y map x, y starting coordinates, positive integer number Other required commands Example 502 The FMTU command instructs the generator to use the new setting. The ALLU command updates hardware to the new setting and redraws the test image. RMAP 20 5 MyMap ALLU Appendix A Command Reference // Renders MyMap at X=20, Y=5 // Update hardware to current buffer contents ROWI ROW Insert Class Description Command syntax Bitmap editor function Inserts a row of pixel data into the bitmap that is being edited. The existing pixel data in the selected row and higher number rows are bumped up one row to make room for the new pixel data. ROWI row hexstring row integer min = max = hexstring hexadecimal number Other required commands Example A bitmap editing session must have been opened with a MAPB command. ROWI 1 FFDE54F Video Test Generator User Guide // insert new row 1 503 ROWQ? bitmap row Query pointer Class Description Query syntax Bitmap editor function Returns the pixel data for the given row for the current contents of the bitmap editor buffer. ROWQ? row max row positive integer number max positive integer number Query response Other required commands Example 504 Hexstring of one or more characters consisting of 0-9 and A-F. A bitmap editing session must have been opened with a MAPB command. ROWQ? 1 // Returns pixel data for row 1 Appendix A Command Reference ROWY ROW Yank Class Description Command syntax Bitmap editor function Deletes a row of pixel data in the bitmap that is being edited. The pixel data in the higher number rows are bumped down one row to fill in the gap. ROWY row row positive integer Other required commands Example A bitmap editing session must have been opened with a MAPB command ROWY 2 Video Test Generator User Guide // Delete the pixel data for row 2 505 SAMP Digital Audio Sinewave Amplitude Class Description Command syntax Sonic data generator Sets the amplitude in decibels of the audio stream sinewave output by the generator. SAMP amplitude (sets all channels) amplitude -96.3 to 0 (if NBPA is 16-bits) -120.4 to 0.0 (if NBPA is 20-bits) -144.5 to 0.0 (if NBPA is 24-bits) Query syntax Query response Example Related commands 506 SAMP? amplitude SAMP -60.0 FMTU SRAT, SMIN?, SMAX? Appendix A Command Reference // Sets all channels to -60 amplitude SCAL Self CALibrate Class Description Command syntax System calibration setting Causes a generator equipped with self-calibration circuitry to go through its self-calibration cycle. SCAL Video Test Generator User Guide 507 SCAN SCAN fields per frame Class Description Command syntax Format parameter setting - Video resolution Establishes the number of fields scanned per frame. Set to 1 for progressive (non-interlaced) scan and 2 for interlaced scan. The SCAN? query returns the current setting of SCAN. SCAN fields fields 1 = progressive (non-interlaced) 2 = interlaced Query syntax Query response Other required commands Example 508 SCAN? fields The FMTU command instructs the generator to use the new setting. The ALLU command updates hardware to the new setting and redraws the test image. SCAN FMTU // Select interlace in buffer // Update hardware to current buffer contents Appendix A Command Reference SCTL Set masked ConTroL bits Class Description DVI TMDS Sets the masked control bits for the Broadcom or Silicon Image DVI transmitter chip. The bits to be set are (one byte mapped as follows): CTL13 CTL12 CTL11 CTL10 CTL03 CTL02 CTL01 CTL00 Note: CTL03 is not part of this setting. It controls the HDCP. Command syntax RCTL mask mask hexidecimal Example Related commands SCTL 23 // the 23 in hex sets the CTL00, CTL01 and CTL11 to 1's RCTL Video Test Generator User Guide 509 SDIR Sort DIRectory Class Description Command syntax Other required commands 510 Directory editor control Sorts the names in a directory by alphabetical order. SDIR Directory editing session must have been opened with a DIRB command. Appendix A Command Reference SDLY Sequence step DeLaY Class Description Command syntax Sequence editor control Sets how long a sequence step will pause before advancing to the next step in the auto run mode. A sequence step will use the last value set by the SDLY command. The SDLY? query returns the current setting of SDLY. SDLY delay | -frames delay Delay time in seconds as a floating point number. frames Delay in frames. Type minus (-) character before integer. min = 0.0 seconds; -1 frame max = 1.70E38 seconds (infinite) Query syntax Query response Other required commands Example SDLY? delay SMOD setting must be equal to 3 in order for the SDLY setting to have any affect on sequence operation. SDLY 5.0 SDLY -3 Video Test Generator User Guide // Set delay to five seconds per step // Set delay to three frames per step 511 SDMG Sonic Data Mixer Gate Class Description Sonic data generator Configures the generator to use either an internal or external audio source. Note: Setting the mask “external” bit to 1 causes the SPDIF audio signal to be passed through the generator. In this case, the Audio InfoFrame CT, CC, SF, and SS parameters are set to 0, indicating that the stream header should be used to determine audio coding type, channel type, sampling frequency, and sample size, respectively. If both “external” and “sdg” bits are set to 1 simultaneously, then an error is generated as the generator’s sonic data mixer does not currently support proportional mixing of internal and external sources. Important: Restarting the generator does not change this setting. Command syntax SDMG mask mask 1 = sdg (internal) 2 = external Example 512 SDMG 1 FMTU Appendix A Command Reference SEOS Set End Of String Class Description Command syntax GPIB port control Controls how a generator reads strings, when reading multi-line responses. In GPIB communication both the sender and receiver first have to agree on end-of-string parsing. The SEOS command enables users to determine if the generator should use line feed for end-of-string parsing. SEOS integer integer 0 = Configures the generator to not test end-of-strings, and to send EOI only on the last character of the entire response. Use this option to receive an entire multi-line response in a single read operation. Leave the VISA “Enable Termination Character” option set to FALSE. 1 = Use end-of-string testing (default). Query syntax SEOS? Video Test Generator User Guide 513 SEQA SEQuence save As Class Description Command syntax Sequence memory management Saves the current contents of the sequence edit buffer using the given name. SEQA name name A valid MS-DOS filename (8 characters minus any extension) Example 514 SEQA MY_SEQ // Save with the name "MY_SEQ" Appendix A Command Reference SEQB SEQuence editing Begin Class Description Command syntax Other required commands Example Sequence editor control Marks the beginning of a sequence editing session. SEQB Use either a SEQL command to load an existing sequence or a SEQN command to create a new sequence. Use SEQE when ending the editing session. SEQN SEQB // Initialize sequence edit buffer // Start sequence editing session // One or more sequence editing commands ... SEQE Video Test Generator User Guide // End sequence editing session 515 SEQE SEQuence editing End Class Description Command syntax Other required commands Example Sequence editor control Marks the end of a sequence editing session. SEQE Use SEQB when starting the editing session. Use SEQA or SEQS to save changes. EQB // Start sequence editing session // One or more sequence editing commands ... SEQE SEQA MYSEQ_02 516 Appendix A Command Reference // End sequence editing session // Save edited sequence as "MYSEQ_02" SEQK SEQuence Kill Class Description Command syntax Sequence memory management Deletes a sequence by name. The query returns a 1 if the named sequence can be deleted. If sequence is read-only or non-existent, the query returns a 0. SEQK name name a valid MS-DOS filename (8 characters minus any extension) Query syntax SEQK? name name a valid MS-DOS filename (8 characters minus any extension) Query response Example 0 or 1 SEQK MY_SEQ Video Test Generator User Guide // Delete seq called "MY_SEQ" 517 SEQL SEQuence Load Class Description Command syntax Sequence memory management Copies the sequence having a name equal to name from sequence memory into the sequence edit buffer. The query returns a 1 if the named sequence can be loaded; otherwise, a 0 is returned. SEQL name name a valid MS-DOS filename (8 characters minus any extension) Query syntax SEQL? name name a valid MS-DOS filename (8 characters minus any extension) Query response Other required commands Example 518 0 or 1 An SEQU command must be executed after the SEQL command to start running the sequence. SEQL MY_SEQ SEQU // Load "MY_SEQ" dir in edit buffer // Start running the sequence in the buffer Appendix A Command Reference SEQN SEQuence New Class Description Command syntax Sequence editor control Initializes the sequence edit buffer. The name name is assigned as the sequence's name. The query will return the name that has been assigned as the sequence's name. SEQN name name optional valid MS-DOS filename (8 characters minus any extension) Query syntax Query response Example SEQN? name SEQN // Init edit buffer without assigning a new name or SEQN MY_SEQ Video Test Generator User Guide // Init edit buffer with name of "MY_SEQ" 519 SEQP SEQuence Path Class Description Command syntax Sequence memory management Sets the current sequence path name to a given directory. The query will return the current path name. SEQP name name a valid MS-DOS filename (8 characters minus any extension) Query syntax Query response Example 520 SEQP? Current sequence path name. SEQP BURN // Sequences in BURN directory will be listed Appendix A Command Reference SEQQ? SEQuence Query pointer Class Description Query syntax Sequence memory management Returns number sequence names from the list of all the sequence names stored in sequence memory beginning at index. The directories are kept in alphanumeric order. The generator maintains internal variables for the current index and number values. The value of index is automatically incremented by number after the query is executed. Sending the query with just an index parameter, will return the same number of names as the last time, starting at the given index. Sending the query with no parameters will return the next set of names in the directory buffer. SEQQ? index number index positive integer number number positive integer number Query response List of specified sequence names. Example 1 SEQQ? 1 9999 Example 2 SEQQ? 1 10 SEQQ? 21 SEQQ? Video Test Generator User Guide // List the names of all sequences stored in memory // List names of the first ten sequences stored in memory // List names of the 21st through the 30th sequences // List names of the 31st through the 40th sequences 521 SEQR SEQuence Read Class Description Command syntax Sequence memory management Reads a sequence from the sequence memory location into the sequence buffer. The SEQR command does not run the sequence. The SEQR? query returns the name of the sequence stored in location location or returns the string EMPTY if the sequence memory location location is empty. SEQR location location integer Query syntax Query response Other required commands Example 522 SEQR? location name The SEQU command runs the sequence in the buffer. SEQR 5 ALLU // Load sequence from RAM location 5 // Start using the sequence Appendix A Command Reference SEQS SEQuence Save Class Description Command syntax Sequence memory management Saves the current contents of the generator's sequence edit buffer back to the memory location from which they were originally read. SEQS Video Test Generator User Guide 523 SEQU SEQuence Use Class Description Command syntax Query syntax Query response Other required commands Example 524 Sequence memory management Runs the sequence currently stored in the sequence edit buffer. The SEQU? query returns the sequence name currently set in the sequence edit buffer. SEQU SEQU? name The sequence in the edit buffer must have a non-zero SMOD setting to run. SEQL MY_SEQ SEQU // Load "MY_SEQ" dir in edit buffer // Start running the sequence in the buffer Appendix A Command Reference SIZE SIZE of bit field Class Description Direct processor control Sets the field size (in base 10) used in connection with the GETA, GETR, PUTA, and PUTR commands. If a negative size is specified, then values given (or returned) are sign extended to 32 bits. For example, if SIZE = -16 and a 16 bit field containing FFFF hex is fetched, then the value FFFFFFFF hex is returned. The SIZE? query returns the current setting of SIZE in base 10. SIZE is preset to 16 each time the generator is powered on. Note: This command is used only with custom applications and command files created by Quantum Data. Command syntax SIZE size size -32 to -1 or 1 to 32 bits Query syntax Query response SIZE? size Video Test Generator User Guide 525 SLUT Set Look-Up Table Class Description Command syntax LUT Management Sets up the color look-up-table (LUT) for rendering and displaying selected colors from defined sets. This command is made available for testing low-level drawing firmware and is not intended for use by end users. SLUT colorset colorset integer Bit mask indicating desired color sets Example 526 SLUT 65536 // Setup for HUERGB colorset. Appendix A Command Reference SMAX? Digital Audio Sinewave Maximum Class Description Query syntax Query response Related commands Sonic data generator Returns the maximum amplitude of the digital audio sinewave output from the generator. SMAX? maximum amplitude (0 - 65,535) SRAT, SAMP, SMIN? Video Test Generator User Guide 527 SMIN? Digital Audio Sinewave Minimum Class Description Query syntax Query response Related commands 528 Sonic data generator Returns the minimum amplitude of the digital audio sinewave output from the generator. SMIN? minimum amplitude (0 - 65,535) SRAT, SAMP, SMAX? Appendix A Command Reference SMOD Sequence operating MODe Class Description Command syntax Sequence editor control Sets the sequence mode. The SMOD? query returns the current setting of SMOD. SMOD mode mode 0 = disable 1 = enable manual step mode that stops at last step 2 = enable manual step mode that wraps to first step after last step 3 = enable continuous auto stepping Query syntax Query response Other required commands Example SMOD? mode The SEQL command loads the sequence and SEQU starts to run it. SEQL MY_SEQ SEQU SMOD 3 Video Test Generator User Guide // Load "MY_SEQ" in edit buffer // Start running the sequence in the buffer // Set the sequence mode 529 SNUM draw sequence Step NUMber Class Description Command syntax Custom image primitive Displays the sequence step number to an image when drawn as part of a test sequence. The number, along with the word “Step,” appears in a small box. The SNUM command uses three parameters. The first is the color used for the text and box border. The next two parameters are the x and y coordinates for the position of the box. SNUM color x y color available colors x, y positive integer numbers Other required commands Example 530 The displaying of sequence step numbers must be enabled with the DNUM command, and the custom image must have been loaded as part of a sequence in order for this primitive to be drawn. SNUM white 50 50 Appendix A Command Reference // Display seq. num. in box with top left corner at // X=50, Y=50 SPAX slider image SPAcing X Class Description Command syntax Image editor control Sets the horizontal spacing of certain elements in some built-in test images. The SPAX? query returns the current SPAX setting. SPAX x_spacing x_spacing integer number of pixels Query syntax Query response Example SPAX? x_spacing SPAX 20 Video Test Generator User Guide 531 SPAY slider image SPAcing Y Class Description Command syntax Image editor control Sets the vertical spacing of certain elements in some built-in test images. The SPAY? query returns the current SPAY setting. SPAY y_spacing y_spacing integer number of pixels Query syntax Query response Example 532 SPAY? y_spacing SPAY 20 Appendix A Command Reference SRAT Digital Audio Sinewave Rate Class Description Command syntax Sonic data generator Sets the frequency of the audio sinewave from the generator. SRAT rate rate 20.0 to 20.0E3 (Hz) Query syntax Query response Example Related commands SRAT? rate SRAT 10.0E3 FMTU SAMP, SMAX?, SMIN? Video Test Generator User Guide 533 SROP Set/Reset OPeration Class Description Command syntax Sets or resets one or multiple power-on special modes (see GenOps image). SROP set_mask reset_mask set_mask Value to set. reset_mask Value to reset. Use this parameter to establish all bits with one command, or to individually set, or reset bits without changing others. The mask value is constructed as follows: 534 Mask value Description 1 Old format names. Enabling or disabling this mode with re-initialize the generator. 2 Digital friendly 4 Analog friendly 8 Display status on LCD 16 Reset HDCP Rx (Silicon Image friendly mode) 32 Calibrate 64 Clone 128 Key pad 256 Sony baud rate 9600 512 Programmable key pad 1024 Program mode 2048 Digital YCbCr mode 4096 DCS Priority mode 8192 HDCP Test mode 16384 Use hot-plug special format mode 32768 DVI mode (disables HDMI mode) 65536 Bypass “hot-plug” format special mode (for DVI and HDMI outputs). Appendix A Command Reference Query syntax Query response Example 1 SROP? Returns current SROP mode. If multiple special modes are enabled, the SROP? value is the sum of the mask values for the enabled modes. R:\SROP 8 R:\SROP 2 R:\SROP? 10 Example 2 SROP 2 // set digital friendly mode SROP 4 // set analog mode Example 3 For generators with HDMI option: SROP 32768 // Enable DVI mode (disable HDMI mode) SROP 0 32768 // Enable HDMI mode Video Test Generator User Guide 535 SSST Select Sync Signal Type Class Description Command syntax Format parameter setting - Synchronization Selects the type of sync signal used to synchronize the display. In general, any one of three different types of sync can be selected to synchronize the display. The availability of different sync types is specified using the ASCT, DSCT, and DSST commands. Some displays may not accept one (or more) types of sync. For example, a digital video monitor cannot accept analog composite sync because analog signal transmission is not used. Also, a PGA display cannot accept digital separate HS and VS because only one sync wire is provided in the cabling. In these cases, one (or more) of the sync types (ASCT, DSCT, or DSST) is set to 0, indicating that they are not supported. If a non-supported sync type is selected using the SSST command, then the corresponding sync outputs of the generator will remain disabled. The SSST? query returns the type of sync (if any) that is currently selected. SSST type type 0 = no sync 1 = digital separate horizontal and vertical sync ( DHS & DVS ) 2 = digital separate composite sync ( DCS ) 3 = analog composite sync ( ACS ) 4 = analog composite sync ( ACS ) 5 = DSS and ACS 6 = DCS and ACS 7 = DSS, DCS, and ACS 8 = DPMS-OFF (DSS) 9 = DPMS-SUSPEND (DSS) 10 = DPMS-STANDBY (DSS) 11 = DCS & DSS Query syntax Query response 536 SSST? type Appendix A Command Reference Other required commands Example The desired sync type selected must not be set to void with the ASCT, DSCT, or DSST commands. To actually output the selected sync signal, it must be gated on with the appropriate ASSG, ASBG, ASGG, ASRG, CSPG, HSPG, and VSPG settings. DSST HSPG VSPG SSST FMTU 1 1 1 1 Video Test Generator User Guide // // // // // Set Amer. H&V in buffer Enable H sync in buffer Enable V sync in buffer Select sep H&V sync in buffer Update hardware to current buffer contents 537 STRG STRetchinG SCL Low Signal Class Description EDID and DDC control Enables a stretching capability for the receiver of the HDMI analyzer. Each time a host accesses the I2C receiver bus (for example, to read the EDID), the receiver stretches the SCL low signal for 5 ms. Enable stretching for testing purposes only. Command syntax STRG value value 0 = deactivate stretching 1 = activate stretching of SCL low signal for 5 ms Query syntax Query response Example Related commands 538 STRG? 0 or 1 STRG 1 DIDU DIDU Appendix A Command Reference STEP sequence STEP number Class Description Sequence editor control Selects a step in the sequence edit buffer. It is context sensitive. While editing a sequence (between SEQB and SEQE commands), the STEP command selects a step to be edited. Outside of the sequence editor and while running a sequence, the command selects a step to be executed. The STEP? query returns the current setting of STEP. Command syntax STEP step step min = 1 max = See description Query syntax Query response Other required commands Example STEP? step When running a sequence, the SEQU command must be executed after the STEP command to load the format and display the image selected in the step. STEP 5 SEQU Video Test Generator User Guide // Select fifth step in current sequence // Load format and draw image in current step 539 SVSG Single Video Signal Gating Class Description Command syntax Video Gate Determines which output colors are enabled. The SVSG? query returns the current SVSG setting. SVSG gate_mask gate_mask Gate Mask Query syntax Query response Example 540 Red Green Blue 0 Off Off Off 1 Off Off On 2 Off On Off 3 Off On On 4 On Off Off 5 On Off On 6 On On Off 7 On On On SVSG? gate_mask SVSG 7 Appendix A Command Reference SXAR Signal Aspect Ratio Class Description Command syntax Format parameter setting - HDMI active video Sets the natural aspect ratio of the video signal format (or “coded frame”) that transports images to the display. SXAR aspect_ratio aspect_ratio 0.75 to ˜2.39 Note: For a listing of established aspect ratios, see the table on page 262 (CXAR command). Related commands Example CXAR, EXAR SXAR 1.33 // Sets 4:3 video signal aspect ratio for source content FMTU Video Test Generator User Guide 541 SXCX Signal-From-Content Aperture Map Class Description Format parameter setting - HDMI active video Sets the proper parameters to values necessary to fit CXAR-shaped image content to the SXAR-shaped aperture of the signal interface timing format. Upon executing this command, the following actions are performed: 1. The EXAR value is set to the CXAR value (EXAR=CXAR). 2. The EXCX value is set to 0 (EXCX=0). 3. The SXEX value is set to value entered for this command (SXEX=SXCX). Command syntax SXCX code code 0 to 131071 (in decimal) Note: For help in determining the proper mapping code, follow the procedure on page 318 (EXCX command). Related commands Example 542 SXEX, EXAR, EXCX, CXAR, SXCX, SXAR SXCX 264 //Use centered shrink w/black bars top & bottom FMTU Appendix A Command Reference SXEX Signal-From-Extended Aperture Map Class Description Command syntax Format parameter setting - HDMI active video Maps EXAR-shaped image content into the SXAR-shaped signal interface. SXEX code code 0 to 131071 (in decimal) The mapping code is made up of three binary field codes as follows: • Bits 0-2 are the Squeeze/Stretch (“S”) field code • Bits 3-9 are the Letterbox/Pillar (“L”) field code • Bits 10-16 are the Safe Area (“K”) field code Note: For help in determining the proper mapping code, follow the procedure on page 318 (EXCX command). Related commands Example EXAR, SXAR, EXCX, SXCX SXEX 264 //Use centered shrink w/black bars top & bottom FMTU Video Test Generator User Guide 543 TBOX draw information Text BOX Class Description Command syntax Custom Image Primitive Renders an information text box that can be added to custom images. This command allows color, position, information, and box type to be customized. TBOX color %x %y info type color valid color name %x 0.0 to 1.0 normalized positioning of box center in the x direction %y 0.0 to 1.0 normalized positioning of box center in the y direction info 0 = format, image, line-rate, and frame-rate (default = 1 = format 2 = image 3 = sequence 4 = step number 5 = format and image 6 = sequence and step 7 = line-rate and HRES X VRES 8 = pixel-rate and HRES X VRES 9 = format, image, sequence, and step 10 = format, image, HRES X VRES, and pixel rate 11 = line-rate, frame-rate, sequence, and step 12 = pixel-rate, HRES X VRES, sequence, and step 13 = line-rate, frame-rate, pixel-rate, and HRES X VRES 14 = format, image, line-rate, frame-rate, sequence, and step 15 = format, image, HRES X VRES, pixel-rate, sequence and step 544 Appendix A Command Reference type 0 = text only 1 = text w/ border 2 = text w/ black background 3 = text w/ border and black background Query syntax Query response Other required commands Example TBOX? color %x %y info type TBXG TBOX white 0.5 0.5 8 3 Video Test Generator User Guide 545 TBXG Text BoX Gating Class Description Command syntax Enables and disables the displaying of the text box defined by the TBOX command. The TBXG? query returns the current TBXG mode. TBXG mode mode integer 0 = OFF 1 = ON Query syntax Query response mode Other required commands TBOX Example 546 TBXG? TBXG 1 Appendix A Command Reference TEXT draw TEXT string Class Description Custom image primitive Draws a user-defined text string. It uses five parameters. The first is color. The next two are the x and y coordinates for the upper left corner of the starting position of the string. The fourth parameter selects the font. The last parameter is the text string. If the string is longer than one word, it must be contained inside quotation marks. All of the characters in the text string must have matching characters in the font selected by font name. Command syntax Text color x y font "text " color available colors x, y coordinates of top left corner of page in pixels font available fonts text approximately 30 characters (must be enclosed by quotes) Other required commands Example The FMTU command instructs the generator to use the new setting. The ALLU command updates hardware to the new setting and redraws the test image. TEXT red 50 40 opix9 "HELLO WORLD" // Draw red "HELLO WORLD" at x=50 y=40 in opix9 font Video Test Generator User Guide 547 TMAU Timing Measurement Analyzer Use Class Description DVI signal analyzer Initiates a measurement of the timing received from an external DVI source (via the DVI Input connector). To do this, the PNSF command must be set to MEASURED. Measured parameters are written into the format buffer. Note: If PNSF is set to CURRENT, then the TMAU command leaves the parameters of the currently selected format in the format buffer. The timing parameters can be read back via queries using the following commands Command syntax 548 SCAN? Returns the scan type PRAT? Returns the pixel rate (in Hz) FRAT? Returns the frame rate (in Hz) VRAT? Returns the vertical (field) rate (VRAT = FRAT * SCAN) HTOT? Returns the horizontal total (in pixels) HRES? Returns the horizontal active (in pixels) HSPD? Returns the horizontal sync pulse delay (in pixels) HSPW? Returns the horizontal sync pulse width (in pixels) HSPP? Returns the horizontal sync pulse polarity VTOT? Returns the vertical total (in lines) VRES? Returns the vertical active (in lines) VSPD? Returns the vertical sync pulse delay (in lines) VSPW? Returns the vertical sync pulse width (in lines) VSPP? Returns the vertical sync pulse polarity HVPD? Returns the pixel delay between the H and V sync pulses. TMAU Appendix A Command Reference Example PNSF 1 //Pseudo-random noise signal format set to MEASURED PNST 1 //Pseudo-random noise signal type set to QDI-BCM TMAU //Measure external signal’s timing format parameters HTOT? //Read external signal’s total number of horizontal pixels 800 HRES? //Read external signal’s total number of active horizotan pixels 640 Video Test Generator User Guide 549 TOBL set levels relative TO BLanking Class Description Command syntax 550 Custom image primitive Temporarily changes how the signal levels are determined for a given color intensity level. The default method uses black as the 0% reference level and peak video as the 100% level. Inserting TOBL moves the 0% reference point to the blanking (blacker than black) pedestal level. The reference point remains shifted only for as long as the image is displayed. TOBL Appendix A Command Reference TRIA draw a TRIAngle Class Description Command syntax Custom image primitive Draws a triangle defined by its three end points. The primitive uses eight parameters. The first is line color. The next three pairs of parameters are the x and y coordinates for the three points. The last parameter is the fill. More complex filled polygons can be built up using a series of joined filled triangles. TRIA color x1 y1 x2 y2 x3 y3 fill color available colors x1, y1, x2, y2, x3, y3 positive integer number fill available fill pattern Other required commands Example The FMTU command instructs the generator to use the new setting. The ALLU command updates hardware to the new setting and redraws the test image. TRIA red50 10 5 10 25 40 15 GrayPat50 // Draw a red50 triangle at x=10, // y=5; x=10, y=25; x=40, y=15 with // 50% active pixel fill ALLU // Update hardware to current // buffer contents Video Test Generator User Guide 551 TTLL Class: Description Command syntax Sets the output voltage of the TTL interface on the 802R-PCI generator. The query reads the current value. TTLL voltage voltage 3.3 5.0 Query syntax Example 552 TTLL? TTLL 5.0 // sets the output voltage to 5V on the TTL interface Appendix A Command Reference UIDN User IDeNtification Class Description Command syntax System parameter settings Sets up the text string that is placed in the upper portions of the SMPTE133 and Cubes images. The command can be used to add a company name or other identification to the images. The command will not change the text in a currently displayed image; it must be redrawn to use the new text. The factory default string is “Quantum Data.” The UIDN? query returns the current text string. UIDN string string text string 80 characters in length Query syntax Query response Other required commands Example UIDN? string The IMGU command redraws the last selected test image. The ALLU command updates hardware to the new setting and redraws the test image. UIDN "XYZ Monitor Mfg." IMGL SMPTE133 IMGU Video Test Generator User Guide // Change text string // Select image that uses the text string // Draw the image using new string 553 UNPK UnPacK operation related to DMA Class Description Command syntax 554 Unpacks archived data received by the YMDI command and puts it in the proper memory locations UNPK Appendix A Command Reference USIZ Unit of measure used for physical SIZes Class Description System control Sets the units of measure assumed by HSIZ and VSIZ commands to establish the physical size of the image that appears on the CRT (context sensitive; see FMTB and FMTE). The USIZ? query returns the current setting of USIZ. Note: Changing the USIZ parameter between inches and millimeters will convert the current HSIZ and VSIZ values to match the new unit of measure. For example, if USIZ is in inches and the current HSIZ is 10 (inches), changing USIZ from inches to mm will change HSIZ to 25.4 (mm). The USIZ command should be sent before specifying physical sizes in format command files. Command syntax USIZ units units 0 = sizes not given (use default) 1 = inches 2 = mm Query syntax Query response Other required commands Example USIZ? units The ALLU command updates hardware to the new setting and redraws the test image, taking the new units into account. FMTB // Begin editing session // One or more format editing commands ... USIZ 1 HSIZ 10.4 VSIZ 7.8 ALLU // // // // Select inches as unit of measure in buffer Set width to 10.4 in buffer Set height to 7.8 in buffer Test the new settings // One or more format editing commands ... FMTE Video Test Generator User Guide // End editing session 555 UNPK UnPacK operation related to DMA Class Description Command syntax 556 Unpacks archived data received by the YMDI command and puts it in the proper memory locations UNPK Appendix A Command Reference UNPK UnPacK operation related to DMA Class Description Command syntax Unpacks archived data received by the YMDI command and puts it in the proper memory locations UNPK Video Test Generator User Guide 557 VERF? VERsion Firmware Class Description Query syntax Query response Example 558 Miscellaneous system parameters Returns the firmware version number for the runtime code and the boot code. The digits to the left of the decimal point represent the major release level. The digits to the right of the decimal point represent the revision number of the release. A second decimal point followed by more digits indicates the revision is at a given beta test level. VERF? version runtime code: version boot code VERF? 20.0882002,01.03.03 Appendix A Command Reference VERG? VERsion Gateware Class Description Query syntax Query response Example Miscellaneous system parameters Returns the gateware version number for the programmable devices. The digits to the left of the decimal point represent the major release level. The digits to the right of the decimal point represent the revision number of the release. A second decimal point followed by more digits indicates the revision is at a given beta test level. VERG? product code, revision, date code: product code, revsion, date code: product code, revsion, date code VERG? 250C,16,8022004:250F,60,10052004:0,0,0 Video Test Generator User Guide 559 VERH? VERsion Hardware Class Description 560 Miscellaneous system parameters Returns a five-digit hardware version number. The number indicates when a major modification to the hardware was last implemented. The significance of each digit is interpreted as follows: Appendix A Command Reference VRAT? Vertical RATe Query Class Description Query syntax Query response Example Format parameter setting - Video resolution Returns the current vertical (field) rate. This is equal to the product of the FRAT (frame rate) and SCAN (scan type) settings (FRAT * SCAN). VRAT? vertical field rate VRAT? //read the product of FRAT and SCAN settings 50.0000 Related commands TMAU Video Test Generator User Guide 561 VRES Vertical RESolution Class Description Command syntax Format parameter setting - Video resolution Establishes the number of active lines per frame. The VRES? query returns the current setting of VRES. VRES lines lines min = • 1 (when SCAN = 1) or • 2 (when SCAN = 2) max = the lesser of • VTOT-1 (when SCAN = 1) or • VTOT-3 (when SCAN = 2) Must be an even number when SCAN = 2. Query syntax Query response Other required commands Example 562 VRES? lines The ALLU command updates hardware to the new setting and redraws the test image. VRES 480 ALLU // Set 480 active lines in buffer // Configure hardware and redraw image Appendix A Command Reference VSIZ Vertical SIZe Class Description Format parameter setting - Video resolution Establishes the vertical physical size of the image on the display. Units expected (or returned) vary according to the last mode set with USIZ command. The VSIZ command is context sensitive and must appear between begin and end commands FMTB and FMTE. The VSIZ? query returns the current setting of VSIZ. Note: Make sure that the USIZ parameter is properly set before using the VSIZ command. Changing the USIZ setting after entering VSIZ will convert the size to match the new unit of measure. Command syntax VSIZ size size physical size; positive value (floating point accepted) Query syntax Query response Other required commands Example VSIZ? size The units of measure must be properly set by USIZ before entering VSIZ. The ALLU command updates hardware to the new setting and redraws the test image, taking the new size into account. FMTB // Begin editing session // One or more format editing commands ... USIZ 1 HSIZ 10.4 VSIZ 7.8 ALLU // // // // Select inches as unit of measure in buffer Set width to 10.4 in buffer Set height to 7.8 in buffer Test the new settings // One or more format editing commands ... FMTE Video Test Generator User Guide // End editing session 563 VSPD Vertical Sync Pulse Delay Class Description Command syntax Format parameter setting - Synchronization Establishes the delay between leading edge of blanking in the first (or even) field and the leading edge of the vertical sync pulse. When interlacing, delay between end of video and leading edge of vertical sync before second (or odd) field is 0.5 line shorter than the whole-line delay specified. The VSPD? query returns the current setting of the vertical sync pulse delay. VSPD lines lines min =0 (when SCAN = 1) or 1 (when SCAN = 2) max = VTOT-VRES-VSPW (when SCAN = 1) or [(VTOT-VRES-1) /2]-VSPW (when SCAN = 2) Query syntax Query response Other required commands Example 564 VSPD? lines The FMTU command instructs the generator to use the new setting. The ALLU command updates hardware to the new setting and redraws the test image. VSPD 11 FMTU // Set V sync delay to 11 lines in buffer // Update hardware to current buffer contents Appendix A Command Reference VSPG Vertical Sync Pulse Gate Class Description Command syntax Format parameter setting - Synchronization Enables and disables the digital vertical sync output. The VSPG? query returns the current mode of VSPG. VSPG mode mode 0 = OFF 1 = ON Query syntax Query response Other required commands Example VSPG? 0 or 1 To use digital vertical sync, digital separate H and V sync must be selected with the SSST command. The FMTU command instructs the generator to use the new setting. The ALLU command updates hardware to the new setting and redraws the test image. VSPG 1 FMTU Video Test Generator User Guide // Enable V sync output in buffer // Update hardware to current buffer contents 565 VSPP Vertical Sync Pulse Polarity Class Description Command syntax Format parameter setting - Synchronization Establishes the logic sense of the digital vertical sync outputs. Setting polarity to 1 causes the leading edge of vertical sync to be a low-to-high transition. Setting polarity to 0 causes the leading edge of vertical sync to be a high-to-low transition. The VSPP? query returns the current polarity of VSPP. VSPP polarity polarity 0 = high-to-low transition 1 = low-to-high transition Query syntax Query response Other required commands Example 566 VSPP? 0 or 1 In order to use digital vertical sync, it must be gated on with the VSPG command and digital separate H and V sync must be selected with the SSST command. The FMTU command instructs the generator to use the new setting. The ALLU command updates hardware to the new setting and redraws the test image. VSPP 1 VSPG 1 SSST 1 FMTU // // // // Set active hi V sync in buffer Enable V sync output in buffer Select H&V sync type in buffer Update hardware to current buffer contents Appendix A Command Reference VSPW Vertical Sync Pulse Width Class Description Command syntax Query syntax Query response Other required commands Example Format parameter setting - Synchronization Establishes the width of the vertical sync pulse in lines. If the type specified for the selected sync signal (see SSST, ASCT, DSCT, or DSST commands) is one of the CCIR types, then the actual sync pulse width output by the generator will be 1/2 line shorter than the whole number specified. The VSPW? query returns the current setting of VSPW. VSPW lines VSPW? lines The FMTU command instructs the generator to use the new setting. The ALLU command updates hardware to the new setting and redraws the test image. VSPW 3 FMTU Video Test Generator User Guide // Set V sync width to 3 lines in buffer // Update hardware to current buffer contents 567 VTOF Vdram transfer To Flash Class Description Transfers the current contents (no matter what they are) of the video frame buffer to the Flash EEPROM (if equipped) used to store the operating system firmware. EPROM data sent to the generator is normally stored temporarily in video VDRAM. If the file transfer is successful, a loader code segment will be placed in CMOS SRAM and jumped to. This code segment will, in turn, transfer the image of the firmware in VDRAM to flash memory, thereby replacing the entire flash memory contents. Following this, the generator will reboot and re-initialize using the new firmware. Important: Improper use of the VTOF command will cause permanent malfunctioning of the video generator. The VTOF command should be executed only by the Quantum Data ARCHIVE.EXE utility as part of a firmware update operation. On stand-alone generators, the ARCHIVE.EXE utility first copies the new firmware file to the video frame buffer via the serial port. Once the file has been successfully copied to the buffer, the buffer contents are then used to update the Flash EEPROM. Executing the VTOF command when the video frame buffer does not contain a valid firmware file will cause a permanent malfunctioning of the generator. There is no way to restore the firmware on stand-alone models via the serial or GPIB ports once this has occurred. The stand-alone generator must be returned to Quantum Data or a Quantum Data authorized repair center for reprogramming. Note: The firmware may be replaced at least 10,000 times. After that, the generator may require service to replace the flash ROMs. Important: In the unlikely event the power fails while the loader is transferring data from VDRAM to flash memory (this process taking approximately 20 seconds to complete), the generator will appear to be inoperable at the next power-on. To restore operation, the generator must be removed from the system, opened, connected to a computer having a special adapter, and reprogrammed from a binary image file using a special executable program.Is this something the customer can do himself? Or should we advise him to return the generator to the repair center? Command syntax Other required commands 568 VTOF YMDI, FLSH Appendix A Command Reference VTOT Vertical TOTal lines per frame Class Description Format parameter setting - Video resolution Establishes the total number of lines per frame. When interlacing (SCAN=2), VTOT must be odd. The VTOT? query returns the current setting of VTOT. The frame or picture refresh rate is equal to HRAT divided by VTOT. The field or vertical rate is equal to the frame rate when SCAN = 1 (non-interlaced operation). The field or vertical rate is equal to twice the frame rate when SCAN = 2 (non-interlaced operation). Note: The current version of the firmware does not allow you to directly enter a specific field or frame rate when setting up a format. If your test specifications call for a specific field, frame or vertical refresh rate, enter suitable values for HRAT, SCAN and VTOT to give you the desired rate. Command syntax VTOT lines lines must be an odd number when SCAN = 2 min = • 2 @ SCAN=1 • 5 @ SCAN=2 max = Query syntax Query response Other required commands • 801GC-ISA = 4096 @ SCAN=1; 4097 @ SCAN=2 • 801GF-ISA = 4096 @ SCAN=1; 8191 @ SCAN=2 • 801GP = 2048 • 801GC, GX = 4096 @ SCAN=1; 4097 @ SCAN=2 • 801GF = 4096 @ SCAN=1; 8191 @ SCAN=2 VTOT? lines The FMTU command instructs the generator to use the new setting. The ALLU command updates hardware to the new setting and redraws the test image. Video Test Generator User Guide 569 Example 570 VTOT 525 FMTU // Set total lines//frame to 525 in buffer // Update hardware to current buffer contents Appendix A Command Reference XACR Audio Clock Recovery Data Class Description Sonic data generator Sets the N value, and optionally sets the CTS value. The XACR command takes effect (the new N and CTS values are encoded and transmitted to the receiver) after the packet is gated on (DPTG command) and the hardware has been updated (DPGU command). Command syntax XACR n cts n value of audio clock regeneration cts Cycle Time Stamp. If not specified, the hardware will calculate the CTS value. Related Commands DPTG, DPGU Video Test Generator User Guide 571 XAFD AFD Mode Setting Class Description Command syntax Format parameter setting - HDMI active video Sets the SXCX, SXEX, EXAR, EXCX, and CXAR parameters to values necessary to support a given AFD code. XAFD afd_code afd_code 0 to 15 The following table provides a listing of AFD codes and corresponding parameter settings. Note: This command will not change the value of SXAR (which remains fixed by the current format). Therefore, the range of allowed AFD values are determined by the value of SXAR in the current format. AFD Code SXAR CXAR1 EXCX1 EXAR SXEX1 2 1.33 1.77 0 CXAR 280 1.77 1.77 0 CXAR 16 3 1.33 or 1.77 1.55 0 CXAR 280 4 1.33 or 1.77 > 1.77 0 CXAR 264 8 1.33 1.33 0 CXAR 0 1.77 1.33 0 CXAR 0 1.33 1.33 0 CXAR 16 1.77 1.33 0 CXAR 264 1.33 1.77 0 CXAR 264 1.77 1.77 0 CXAR 32 1.33 1.55 0 CXAR 264 1.77 1.55 0 CXAR 264 1.33 1.55 0 CXAR 8 1.77 1.55 8 1.33 264 1.33 1.55 8 1.77 264 1.77 1.55 0 CXAR 8 1.33 1.33 8 1.77 264 1.77 1.33 0 1.33 8 9 10 11 13 14 15 572 Appendix A Command Reference 1. Compound maps involving the EXAR extended aperture and both mapping methods SXEX & EXCX are shown in bold. In these cases, an EXCX–Lcsp operation is first used to place CXAR-shaped content into the EXAR-shaped extended aperture. This operation is then followed by a SXEX-Lcbb operation which finally places the EXAR-shaped extended aperture into the SXAR-shaped output signal aperture. Related Commands Example SXCX, SXEX, EXAR, EXCX, CXAR XAFD 11 //set parameters for AFD code 11 FMTU Video Test Generator User Guide 573 XAUD Audio InfoFrame Data Class Description InfoFrame Generator (IFG) parameter Writes Audio InfoFrame packet data. Command syntax (individual parameter) XAUD:audparameter value Command syntax (complete packet) For uncompressed audio coding type: XAUD type version length [CC [1 [SS [SF [CA [LSV [DMI ]]]]]]] For compressed audio coding types: XAUD type version length [CC [CT [SS [SF [MBR [CA [LSV [DMI ]]]]]]]] type 4 version 1 length (bytes) 10 The remaining are Audio Infoframe data parameters (audparameter) as specified in EIA/CEA-861-B standard, Section 6.3: VERS (same as Version) Infoframe version CC Channel count (see EIA/CEA-861-B standard, Table 19 for settings) CC2 CC1 CC0 Audio channel count 0 0 0 Refer to Stream Header 574 0 0 1 2ch 0 1 0 3ch 0 1 1 4ch 1 0 0 5ch 1 0 1 6ch 1 1 0 7ch 1 1 1 8ch Appendix A Command Reference CT Audio coding type (see EIA/CEA-861-B standard, Table 19 for settings) CT3 CT2 CT1 CT0 Audio Coding Type 0 0 0 0 Refer to Stream Header 0 0 0 1 IEC60958 PCM [26, 27] 0 0 1 0 AC-3 0 0 1 1 MPEG1 (Layers 1 & 2) 0 1 0 0 MP3 (MPEG 1 Layer 3) 0 1 0 1 MPEG2 (multichannel) 0 1 1 0 AAC 0 1 1 1 DTS 1 0 0 0 ATRAC SS Sample size (see EIA/CEA-861-B standard, Table 20 for settings) SS1 SS0 Sample Size 0 0 Refer to Stream Header 0 1 16 bit 1 0 20 bit 1 1 24 bit SF Sampling frequency (see EIA/CEA-861-B standard, Table 20 for settings) SF2 SF1 SF0 Sampling Frequency 0 0 0 Refer to Stream Header 0 0 1 32 kHz 0 1 0 44.1 kHz (CD) 0 1 1 48 kHz 1 0 0 88.2 kHz 1 0 1 96 kHz 1 1 0 176.4 kHz 1 1 1 192 kHz MBR Maximum bit rate (this setting multiplied by 8KHz represents the maximum bit rate of the audio stream) CA Channel assignment code (see EIA/CEA-861-B standard, Table 22 for settings) Note: Setting the XAUD:CA value will automatically set both DACA and DAXA to corresponding values. See the table on page 271 to view these settings. 7 6 5 Video Test Generator User Guide 4 CA 3 2 1 0 8 7 6 Channel Number 5 4 3 2 1 575 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 CA 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 0 0 0 0 1 1 1 1 0 0 0 0 1 1 1 1 0 0 0 0 1 1 1 1 0 0 0 0 1 1 1 1 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 RRC RRC RRC RRC FRC FRC FRC FRC FRC FRC FRC FRC FRC FRC FRC FRC RC RC RC RC RLC RLC RLC RLC FLC FLC FLC FLC FLC FLC FLC FLC FLC FLC FLC FLC Channel Number FC FC RC RC RC FC RC FC RR RL RR RL RR RL FC RR RL FC RR RL RR RL RR RL FC RR RL FC RR RL RR RL RR RL FC RR RL FC FC FC RC RC RC FC RC FC RR RL RR RL RR RL FC RR RL FC LFE LFE LFE LFE LFE LFE LFE LFE LFE LFE LFE LFE LFE LFE LFE LFE LSV Level shift value (see EIA/CEA-861-B standard, Table 23 for settings) LSV3 LSV2 LSV1 LSV0 Level Shift Value 0 0 0 0 0dB 576 0 0 0 1 1dB 0 0 1 0 2dB 0 0 1 1 3dB 0 1 0 0 4dB 0 1 0 1 5dB 0 1 1 0 6dB 0 1 1 1 7dB 1 0 0 0 8dB 1 0 0 1 9dB 1 0 1 0 10dB 1 0 1 1 11dB 1 1 0 0 12dB 1 1 0 1 13dB Appendix A Command Reference FR FR FR FR FR FR FR FR FR FR FR FR FR FR FR FR FR FR FR FR FR FR FR FR FR FR FR FR FR FR FR FR FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL FL LSV3 LSV2 LSV1 LSV0 Level Shift Value 1 1 1 0 14dB 1 1 1 1 15dB DMI Down-mix inhibit (see EIA/CEA-861-B standard, Table 24 for settings) DM_INH Describes whether the down mixed stereo output is permitted 0 Permitted or no information about any assertion of this 1 Query syntax Query response Example 1 Prohibited XAUD:audparameter? value The following example sets the number of audio channels (CC parameter) to 2 in the Audio Infoframe. XAUD:CC 2 IFGU Example 2 The following example sets an Audio InfoFrame with these properties: • Seven channels (CC parameter) • MPEG1 coding type (CT parameter) • 16-bit sample size (SS parameter) • 88.2KHz frequency (SF parameter) • 72KHz maximum bit rate (MBR parameter) • All but channel 3 (LFE) are allocated (CA parameter) • 10dB attenuation during source device down-mixing (LSV parameter) • Down-mixing permitted (DMI parameter) XAUD 4 1 10 6 3 1 4 9 18 10 0;IFGU Example 3 The following example reports the current setting for the Member Bit Rate parameter in the Audio Infoframe. XAUD:MBR? Related commands IFTR, IFTG, IFGU, DAXA, DACA Video Test Generator User Guide 577 XAVI Auxiliary Video Information InfoFrame Data Class Description InfoFrame Generator (IFG) parameter Writes Auxiliary Video Information (AVI) InfoFrame packet data. Command syntax (individual parameter) XAVI:aviparameter value Command syntax (complete packet–version 1) XAVI type version length [S [B [A [Y [R [M [C [SC [ETB [SBB [ELB [SRB ]]]]]]]]]]]] Command syntax (complete packet–version 2) XAVI type version length [S [B [A [Y [R [M [C [SC [ETB [SBB [ELB [SRB [VIC [PR]]]]]]]]]]]] type 2 version 1 = version 1 2 = version 2 length (bytes) 13 The remaining are AVI Infoframe data parameters (aviparameter) as specified in EIA/CEA-861-B standard, Section 6.1: VERS (same as Version) Infoframe version: 1 = version 1 2 = version 2 S Scan information (see EIA/CEA-861-B standard, Table 8 for settings) S S 1 0 Scan Information 0 0 No Data 0 1 Overscanned (television) 578 1 0 Underscanned (computer) 1 1 Future Appendix A Command Reference B Bar information (see EIA/CEA-861-B standard, Table 8 for settings) B B 1 0 Bar Information 0 0 Bar data not valid 0 1 Vertical Bar info valid 1 0 Horizontal Bar info valid 1 1 Vertical & Horizontal Bar info valid A Active Format Information (AFD) present (see EIA/CEA-861-B standard, Table 8 for settings) A Active Format Information 0 Present 0 No data 1 Active format information valid Y Video type (see EIA/CEA-861-B standard, Table 8 for settings) Y Y 1 0 RGB or YCbCr 0 0 RGB (default) 0 1 YCbCr 4:2:2 1 0 YCbCr 4:4:4 1 1 Future R Active Format Aspect Ratio (ADF value) (see EIA/CEA-861-B standard, Table 9 for settings) R R R R 3 2 1 0 Active Format Aspect Ratio 1 0 0 0 Same as picture aspect ratio 1 0 0 1 4:3 (Center) 1 0 1 0 16:9 (Center) 1 0 1 1 other values 14:9 (Center) Per DVB AFD active_format field M Picture Aspect Ratio (see EIA/CEA-861-B standard, Table 9 for settings) M M Picture Aspect 1 0 Ratio 0 0 No data 0 1 4:3 1 0 16:9 Video Test Generator User Guide 579 M M Picture Aspect 1 0 Ratio 1 1 Future C Colorimetry (see EIA/CEA-861-B standard, Table 9 for settings) C C 1 0 Colorimetry 0 0 No data 0 1 SMPTE 170M ITU601 1 0 ITU709 1 1 Future SC Non-uniform Picture Scaling (see EIA/CEA-861-B standard, Table 11 for settings) SC SC 1 0 Non-Uniform Picture Scaling 0 0 No known non-uniform scaling 0 1 Picture has been scaled horizontally 1 0 Picture has been scaled vertically 1 1 Picture has been scaled horizontally and vertically ETB Line number of end of top bar representing the last line of a horizontal letterbox bar area at the top of the picture (0 = no horizontal bar present at top of picture). SBB Line number of start of bottom bar representing the first line of a horizontal letterbox bar area at the bottom of the picture. ELB Pixel number of end of left bar representing the last horizontal pixel of a vertical pillar-bar area at the left side of the picture (0 = no vertical bar present at left of picture). SRB Pixel number of start of right bar representing the first horizontal pixel of a vertical pillar-bar area at the left side of the picture. VIC Video Format Identification Codes (see DVIC for settings). PR Pixel repetition for “2x” and “4x” formats (see EIA/CEA-861-B standard, Table 14 for settings) This field is set automatically based on settings for NCPP and NPPP. PR PR PR PR 3 2 1 0 Pixel Repetition for Optional (2880) 0 0 0 0 No Repetition (i.e. pixel sent once) 0 580 0 0 Appendix A Command Reference 1 Pixel sent 2 times (i.e. repeated once) PR PR PR PR 3 2 1 0 Pixel Repetition for Optional (2880) 0 0 1 0 Pixel sent 3 times Query syntax Query response Example 1 0 0 1 1 Pixel sent 4 times 0 1 0 0 Pixel sent 5 times 0 1 0 1 Pixel sent 6 times 0 1 1 0 Pixel sent 7 times 0 1 1 1 Pixel sent 8 times 1 0 0 0 Pixel sent 9 times 1 0 0 1 Pixel sent 10 times XAVI:aviparameter? value The following example sets the scan information (S parameter) to overscanned in the AVI Infoframe. XAVI:S 1 IFGU Example 2 The following example sets the AFD flag (A parameter) to not present and the picture aspect ratio (M parameter) to 4:3 in the AVI Infoframe. XAVI: A 0; M 1;IFGU Example 3 The following example sets an Audio InfoFrame (version 2) with these properties: • Overscanned (S parameter) • Bar information not valid (B parameter) • Active format information valid (A parameter) • YCbCr video type (Y parameter) • Active format aspect ratio same as picture format ratio (R parameter) • 4:3 picture aspect ratio (M parameter) • SMPTE 170M colorimetry (C parameter) • No known non-uniform scaling (SC parameter) • No specified line number for horizontal bar (ETB and SBB parameters) • No specified pixel number for vertical bar (ELB and SRB parameters) • 480p59 video format (VIC format) • No pixel repetition (PR format) XAVI 2 1 13 1 0 1 2 8 1 1 0 0 0 0 0 2 0;IFGU Video Test Generator User Guide 581 Example 4 The following example reports the current settings for the following AVI Infoframe parameters: • Video Type • Active Format Information present • Bar information present • Scan information • Colorimetry XAVI:Y? XAVI:A? XAVI:B? XAVI:S? XAVI:C? Related commands 582 DVIC, NPPP, IFTR, IFTG, IFGU Appendix A Command Reference XBBH Arbitrary Bottom Border Height Class Description Command syntax Format parameter setting - HDMI active video Establishes the first line of a horizontal letterbox bar area at the bottom of the image. XBBH line_number line_number 0 to 65535 (in decimal) Related commands Example XLBW, XRBW, XTBH XBBH 769 FMTU Video Test Generator User Guide 583 XDID EDID Data Write Class Description Command syntax EDID and DDC control Writes new EDID structure for DVI Analyzer receiver. XDID offset bytes data offset (hex) address offset (in bytes) bytes number of bytes (hex) data data (hex) Example 1 To change the first 3 bytes of the EDID structure (after the header): XDID 8 3 DE33FF DIDU Example 2 To write at offset 256 (start of block 2): XDID 100 8 1122334455667788 XDID 108 8 8899AABBCCDDEEFF DIDU Related commands 584 DIDU Appendix A Command Reference Video Test Generator User Guide 585 XGCP General Control Parameter Data Class Description Data island packet generator Enables and disables the HDMI Audio/Video Mute (AVMUTE) feature. When enabled, audio and video are muted by the generator. Important: You can set either the AVMUTE set flag (to turn mute on) or the AVMUTE clear flag (to turn mute off) to 1 (but not both). Note: The status of the mute is changed only after the packet is gated ON (DPTG), the repeat mode has been set (DPTR), and the hardware has been updated (DPGU) (see example below). Command syntax XGCP AVMUTE_set_flag AVMUTE_clear_flag AVMUTE_set_flag 0 = off 1 = on AVMUTE_clear_flag 0 = off 1 = on Related commands Example 1 MUTE, DPTG, DPGU To enable AVMUTE: DPTG 7 DPTR 1 XGCP 1 0 DPGU Once executed, use the MUTE? to continuously check until the AVMUTE state is changed (may not take place right away). Example 2 To disable AVMUTE: DPTG 7 DPTR 1 XGCP 0 1 DPGU Again, use the MUTE? command to continuously check until the AVMUTE state is changed. 586 Appendix A Command Reference XGDP Generic Data Packet Data Class Description Data island packet generator Writes a generic data packet for sourcing highly-customized arbitrary data. Command syntax (individual parameter) XGDP:gdpparameter value Command syntax (complete packet) XGDP data data (ASCII) hexidecimal payload data in the form of ASCII characters (“0” through “F”)—each representing one 4-bit nibble of data (if less than 60 ASCII characters, which is less than 30 bytes of data, are specified, then the remaining bytes are set to zero) The following are data island packet parameters (gdpparameter) as specified in HDMI specification, Section 5.3. hb0 Packet type (see HDMI specification, Section 5.3.1 through 5.3.6 for settings) hb1 Packet-specific data (see HDMI specification, Section 5.3.1 through 5.3.6 for settings) hb2 Packet-specific data (see HDMI specification, Section 5.3.1 through 5.3.6 for settings) pb0 – pb27 InfoFrame packet data (see HDMI specification, Section 5.3.5 for settings) Example Video Test Generator User Guide 587 XGIF Generic InfoFrame Data Class Description InfoFrame Generator (IFG) parameter Writes generic InfoFrame packet data. This allows you to emulate any InfoFrame type (including vendor-specific). Note: The HDMI specification (section 5.2.3.2) requires that an HDMI packet must be transmitted at least every two VSYNC periods, or the receiver will drop out of HDMI mode. A Generic InfoFrame packet can be used for this purpose by enabling its repeat bit (see the IFTR command). Command syntax XGIF type version length data type 0 to 255 version 0 to 255 length (bytes) 0 to 25 (bytes) data (ASCII) hexidecimal payload data in the form of ASCII characters—each representing one 4-bit nibble of data (if less than 50 ASCII characters, which is less than 30 bytes of data, are specified, then the remaining bytes are set to zero) Example The following example writes 10 bytes of generic InfoFrame data. The remaining bytes 11-25 will be set to zero. XGIF 6 1 20 1122EE4455BB77FF99AA Related commands 588 IFTR, IFTG, IFGU Appendix A Command Reference XLBW Arbitrary Left Border Width Class Description Command syntax Format parameter setting - HDMI active video Establishes the last horizontal pixel of a vertical pillar-box bar area at the left side of the image. XLBW pixel_number pixel_number 0 to 65535 (in decimal) Related commands Example XBBH, XRBW, XTBH XLBW 64 FMTU Video Test Generator User Guide 589 XMPG MPEG InfoFrame Data Class InfoFrame Generator (IFG) parameter Description Writes MPEG InfoFrame packet data. Command syntax (individual parameter) XMPG: mpgparameter value Command syntax (complete packet) XMPG type version length [MB [MF [FR]]] type 5 version 1 length (bytes) 10 The remaining are MPEG Infoframe data parameters (mpgparameter) as specified in EIA/CEA-861-B standard, Section 6.4: VERS (same as Version) Infoframe version MB MPEG bit rate (Enter rate in Hertz [Hz]) [In decimal or hex??] MF MPEG frame (see EIA/CEA-861-B standard, Table 26 for settings) FR Field repeat (see EIA/CEA-861-B standard, Table 26 for settings) Query syntax Query response 590 XMPG:mpgparameter? value Appendix A Command Reference XRBW Arbitrary Right Border Width Class Description Command syntax Format parameter setting - HDMI active video Establishes the first horizontal pixel of a vertical pillar-bar area at the right side of the image. XRBW pixel_number pixel_number 0 to 65535 (in decimal) Related commands Example XLBW, XTBH, XBBH XRBW 961 FMTU Video Test Generator User Guide 591 XRES X axis RESolution for custom images Class Description Command syntax Image editor control Sets the width factor used to scale horizontal size and position parameters in the primitives of a custom image in the image editor buffer. The XRES? query returns the current XRES setting. XRES width width integer 16 to 65,536 Query syntax Query response Example 592 XRES? width XRES 1600 YRES 900 // Set horizontal scaling factor to 1600 // Set vertical scaling factor to 900 Appendix A Command Reference XSPD Source Product Description InfoFrame Data Class Description InfoFrame Generator (IFG) parameter Writes Source Product Description InfoFrame packet data. Command syntax (individual parameter) XSPD: spdparameter value Command syntax (complete packet) XSPD type version length [VNS [PDS [SDI]]] type 3 version 1 length (bytes) 25 The remaining are Source Product Description Infoframe data parameters (spdparameter) as specified in EIA/CEA-861-B standard, Section 6.2: VERS (same as Version) Infoframe version VNS Vendor name string PDS Product description string SDI Source device information (see EIA/CEA-861-B standard, Table 17 for settings) Query syntax Query response Example XSPD:spdparameter? value The following example sets the vendor name string (VNS parameter) to “QDI” in the Source Product Description Infoframe. IFGU XSPD:VNS QDI Video Test Generator User Guide 593 Example 2 The following example specifies a Source Product Description InfoFrame with these properties: • Vendor name is QDI • Product description is HDMI-Analyzer • Source device is Digital STB (1) XSPD 3 1 25 QDI HDMI-Analyzer 1 Example 3 The following example reports the current setting for the Product Description parameter in the Source Product Description Infoframe. XSPD:PDS? 594 Appendix A Command Reference XTBH Arbitrary Top Border Height Class Description Command syntax AFD control parameter Establishes the last line of a horizontal letterbox bar area at the top of the image. XTBW line_number line_number 0 to 65535 Related commands Example XLBW, XRBW, XBBH XTBH 15 FMTU Video Test Generator User Guide 595 XVSG Video Signal Gating Class Description Command syntax Format parameter settings Determines which video outputs are active when the format is selected. The same command controls both the analog and digital video outputs. XVSG red_mode, green_mode, blue_mode red_mode, green_mode, blue_mode 0 = OFF 1 = ON Other required commands Example 596 The FMTU command instructs the generator to use the new setting. The ALLU command updates hardware to the new setting and redraws the test image. XVSG 1 1 1 FMTU // Enable all color channels // Update hardware to current buffer contents Appendix A Command Reference YMDI Y MoDem Input Class Description System Level Initiates the YMODEM-BATCH file-upload protocol. Customization data stored in a battery-powered NVRAM should be backed-up on a PC so, if a battery failure or other problem occurs, recovery will be possible without having to re-enter data by hand. Restoration can be accomplished in three ways: • By sending parameters one-at-a-time • By host port binary data transfer • By standard YMODEM-BATCH file-upload protocol. The YMDI command is used to initiate the YMODEM-BATCH file-upload protocol. The protocol allows one (or more) data structures to be reinstated in the generator from a binary file. A file contains all instances of a particular type of data. For example, sending the FORMAT.MEM file to the generator will restore all user-defined formats. Note that you should not attempt to restore the system parameters by sending SYSTEM.SYS. The YMDI command internally executes UNPK after all files have been received, so UNPK does not need to be sent after YMDI. The YMDI command can also be used to change the firmware in the generator’s flash EPROM via the serial port. This is accomplished by sending the FIRMWARE.BIN file to the generator using a YMODEM-BATCH. The generator temporarily places the FIRMWARE.BIN data in picture memory and, if received intact, eventually transfers this binary image to flash memory by internally executing the VTOF function. Note that you do not have to send VTOF after a YMDI firmware upload. Command syntax YMDI filenamesIs this the correct representation of the syntax? It doesn’t match the example. filenames valid YMODEM-BATCH filenames: DIR.MEM PATH.MEM IMAGE.MEM SEQUENCE.MEM FONT.MEM FORMAT.MEM FIRMWARE.BIN Video Test Generator User Guide 597 Related commands Example 598 YMDO, UNPK, PKUP, VTOF, FLSH YMDI YMODEM-BATCH upload Appendix A Command Reference YMDO Y MoDem Output Class Description System Level Initiates the YMODEM-BATCH file extraction protocol. Customization data stored in a battery-powered NVRAM should be backed-up on a PC so that, if a battery failure or other problem occurs, recovery will be possible without having to re-enter data by hand. Backup can be accomplished in three ways: • By loading and querying parameters one-at-a-time • Extracting binary data using the host port • By standard YMODEM-BATCH file-extraction protocol The YMDO command is used to initiate the YMODEM-BATCH file extraction protocol. The protocol allows one (or more) data structures to be extracted from the generator as binary files. Each file contains all instances of a particular type of data. For example, the FORMAT.MEM file contains all of the user-defined formats stored in the generator. Note that ALL will cause all files except SYSTEM.SYS and FIRMWARE.BIN to be extracted. YMDO internally executes PKUP before sending files, so PKUP does not need to be sent before YMDO. Command syntax YMDO filename [filename [ … ] ] | ALL YMODEM-BATCH download filename Valid filename (listed below) or ALL DIR.MEM PATH.MEM IMAGE.MEM SEQUENCE.MEM FONT.MEM FORMAT.MEM SYSTEM.SYS FIRMWARE.BIN Related commands Example YMDI, PKUP, UNPK YMDO ALL YMODEM-BATCH download Video Test Generator User Guide 599 YRES Y axis RESolution for custom images Class Description Command syntax Image editor control Sets the height factor used to scale vertical size and position parameters in the primitives of a custom image in the image editor buffer. The YRES? query returns the current YRES setting. YRES height height integer 16 to 65,536 Query syntax Query response 600 YRES? height Example XRES 1600 YRES 900 // Set horizontal scaling factor to 1600 // Set vertical scaling factor to 900 Example dirn mydir dirb nami 1 smpte133 nami 2 flat nami 3 raster dire dirs dirl mydir dirb namq? 1 10 namy 2 nami 1 colorbar dire dira newdir dirq? 1 10 Appendix A Command Reference // // // // // // // // // // // // // // // // create a directory named mymap begin directory context insert the name smpte133 at index 1 insert the name flat at index 2 insert the name raster at index 3 end directory context save map named mymap load directory mydir into edit buffer begin directory context list mydir names yank name at index 2 insert new name at index 1 end directory context save modified mydir as newdir list available directories (up to 10 maps starting with the 1st) Video Test Generator User Guide 601 602 Appendix A Command Reference B Image Reference Topics in this appendix: • Standard image descriptions 802BT/802R Video Test Generator User Guide 603 Standard image descriptions Acer1 Description Special test image developed per customer specifications. Consists of two sets of color bars and five blocks of “#” characters on a white crosshatch with a black background. Description Special test image developed per customer specifications. Consists of colorbars, lines of “#” characters, and a green border. Acer2 604 Appendix B Image Reference Acer3, Acer4, Acer5 and Acer6 Description Special test images developed per customer specifications. Consists of large and small white circles centered on either a yellow (Acer3), magenta (Acer4), cyan (Acer5), or white (Acer6) crosshatch on a black background. The Acer3 image is shown below. Acer7 and Acer8 Description Special test image developed per customer specifications. In the primary version, five blocks of either white “#” (Acer7) or “H” (Acer8) characters on a black background are displayed. A secondary version displays black characters on a white background. The Acer7 image is shown below. 802BT/802R Video Test Generator User Guide 605 Acer9 Description Special test image developed per customer specifications. In the primary version, a mostly white field is displayed with two rows of color bars at the bottom. A secondary version displays a black field with the two rows of color bars at the bottom. AFDtest Description Used to test HDMI content mapping using different EIA/CEA-861-B formats. There are 10 different versions of this image. For more information, see “Testing with Active Format Description (AFD)” on page 162. Analyzer Description 606 Used to configure the DVI and HDMI analyzer. For more information, see Chapter 8, “Analyzing Digital Sources and Cables.” Appendix B Image Reference AnsiLght Description The primary version displays a white background with a small black pixel in the center fills the active video area. A secondary version displays a black background with a small white pixel in the center. Apple1 Description Special test image developed per customer specifications. A secondary version shows reverse (black characters on white background). 802BT/802R Video Test Generator User Guide 607 Audio LR, AudioLRf, AudioRAT, Audio_L, Audio_Lf, Audio_R, Audio_Rf Description Used to configure HDMI audio output signal. The AudioLR is shown below. For more information, see “Testing HDMI audio” on page 155. BarBlack Description Special test image developed per customer specifications. A secondary version shows reverse (black lines on white background). BLU_EM, GRN_EM, RED_EM, WHT_EM, MEME1111, MEMESony, MESony_B, MESony_G, and MESony_R Description 608 In the primary version, the screen is filled with blue (BLU and B), green (GRN and G), red (R), or white (WHT, MEME1111, MEMEPlus, and MEMESony) EM character blocks on a black background. Only the white character has a secondary version. It is drawn with black characters on a white background. Appendix B Image Reference A bitmap of a single character block is shown here. The BLU_EM image is shown below. Test Purpose Focus This pattern is specified by some display manufacturers for checking and adjusting focus one color at a time. BLU_EM+, GRN_EM+, RED_EM+, WHT_EM+, MEMEPlus, MEPlus_B, MEPlus_G, and MEPlus_R Description In the primary version, the screen is filled with blue (BLU and B), green (GRN and G), red (R), or white (WHT and Sony) EM character blocks on a black background. Only the white character has a secondary version. It is drawn with black characters on a white background. 802BT/802R Video Test Generator User Guide 609 A bitmap of a single character block is shown here. The BLU_EM+ image is shown below. Test Purpose Focus This pattern is specified by one or more display manufacturers for checking and adjusting focus one color at a time. BLU_PIC, GRAY_PIC, GRN_PIC, RED_PIC, WHT_PIC Description Test 610 A solid blue (BLU), gray, green (GRN), red, or white (WHT) box fills the active video area. Only the white fill has a secondary version. It can be changed to a black fill by pressing the Step key. The BLU_PIC image is shown below. Purity adjustment Appendix B Image Reference Purpose Method To produce correct colors in a displayed image, the electron beams from each of the three (3) guns in the CRT should strike only their matching phosphors. A white image shows patches of various colors on a monitor with bad purity. The purity adjustment(s) should be performed before doing any brightness or color tests. In some cases, purity adjustments involve loosening and repositioning the yoke, in which case purity should be adjusted prior to doing any geometry tests. The methods used for adjusting purity on a color monitor depend on the type of monitor and CRT (for example; Delta, In-Line or Single Gun). In most cases, the first step is to degauss the CRT. Note: For a Delta Gun CRT, turn on only the red output. A solid uniform field of red should appear. If the color is not uniform, adjust the yoke and the Purity Tabs assembly. If purity cannot be corrected to acceptable limits, the monitor may not have been properly degaussed or there may be a defect in the CRT or purity assembly. Test Purpose Method Shadow mask warping The purity characteristics of your CRT can change over time if you leave it on with a lot of video being displayed. This may be due to the CRT’s electron beams striking its shadow mask with enough energy to cause the mask to heat. This internal heating may be enough to cause the shadow mask to warp and give bad purity. Set the purity image to white and allow the monitor to run for a few minutes. Any mask warping shows up as a change in purity. You can use a color meter to measure the change. The BriteBox pattern may also be useful for measuring shadow mask warping. 802BT/802R Video Test Generator User Guide 611 Bosch Description Special test image developed per customer specifications. This image has 6 versions. Box_50mm, Box_64mm, Box100mm, Box150mm, Box200mm, Box250mm Description 612 The primary version has a solid white box in the center of the active video. Depending on the image selected, the box is sized by square millimeters. If there is room, information on the current format appears below and to the left of the box. This shows the number of active pixels and lines as well as the horizontal and vertical scan rates. A forward slash (I) after the number of active lines indicates the format is interlaced. Appendix B Image Reference Note: The box will be the correct size only if the correct physical active video size is set in the format. The Box_50mm image is shown below. The secondary version draws a black box and black text on a white background. Test Brightness control adjustment Purpose The wrong brightness setting may cause other tests such as Contrast, Focus, and Beam Size to be invalid. An accurate brightness setting helps give repeatable measurements throughout other tests. Method Center your light meter probe within the center square and adjust the monitor’s brightness control to obtain the required light meter reading. 802BT/802R Video Test Generator User Guide 613 BriteBox Description Test Brightness control adjustment Purpose The wrong brightness setting may cause other tests such as Contrast, Focus, and Beam Size to be invalid. An accurate brightness setting helps give repeatable measurements throughout other tests. Method Center your light meter probe within the center square and adjust the monitor’s brightness control to obtain the required light meter reading. Test 614 The primary version has a single white box in the center of active video. The box size is controlled by the MSIZ system parameter. The secondary version adds four boxes in the corners of active video. Brightness uniformity Purpose The light output of most picture tubes varies slightly when measured across the CRT face. This test can be used to verify that the light output variation is within your specification limits. Method Select the inverted version and perform the Brightness Control Adjustment test on the center box. Then, center the light meter probe in each of the corner squares and note the reading you get for each square. The deviation between each of the corner readings and the center reading should be within your specification limits. Appendix B Image Reference Burst (TV formats only) Description Test Method The left side starts with reference white (+100 IRE) and black (+7.5 IRE) levels. This is followed by six bursts of sine waves. Each burst is at a different frequency, forming vertical lines of various widths. The frequencies, going from left to right, are 0.5, 1, 2, 3, 3.58, and 4.43 MHz. Frequency response When viewed on a TV screen, the peak intensities of all of the bursts should match the white reference level. The darkest portions between the peaks should match the black reference level. The image can also be used with a TV waveform analyzer to check the frequency response of a video system. One scan line of the image, as it would appear on a waveform analyzer, is shown at the top of the next page . High frequency roll-off (loss) would show up as a decrease in the peak-to-peak swings on the right side of the waveform. Low frequency roll-off would show up as a decrease in the peak-to-peak swings on the left side of the waveform. Some waveform analyzers can be set to detect and display the amplitude of the peaks. A typical amplitude waveform for a good system is shown at the bottom of the next page. 802BT/802R Video Test Generator User Guide 615 BurstTCE Description Fills screen with a 0.5 MHz frequency. This can be increased in 0.5 MHz increments by pressing the Step key, and then turning the Image knob. CardBMP Description 616 Selecting this image loads the BMP image stored on the PCMCIA card inserted into the generator. For more information, see “Downloading bitmap images from a PCMCIA card” on page 78. Appendix B Image Reference Check511 Description Test Purpose Method Consists of five small boxes in the corners and at the center of the active video. The boxes are on a black background. Each box consists of alternating black and white pixels that form a very fine checkerboard. The secondary version inverts the image, creating a white background. The colors of the individual pixels in the boxes also are inverted. Verify monitor resolution The resolution of your monitor should meet or exceed the design specifications. First adjust the brightness, contrast, and focus to their correct settings. You should be able to see individual and distinct pixels in each of the boxes. Failure to see distinct pixels may indicate you have a defective video amplifier, focus correction circuit, or picture tube. Note: If multi-colored areas appear on a mask-type color picture tube, you may have a problem with convergence or you may be exceeding the resolution of the picture tube. 802BT/802R Video Test Generator User Guide 617 CheckBy3 Description Test 618 The active video area is equally divided into a 3x3 checkerboard of black and white boxes. The primary version has four white boxes as shown in the image below. The secondary version has five white boxes (reverse). Contrast ratio Purpose The pattern is based on a proposed ANSI method of measuring the contrast ratio of video projection systems. Method Using a light meter probe, measure and record the light-level reading (in foot lamberts) in the center of each of the black and white boxes. The contrast ratio is expressed as the average of all of the white readings divided by the average of all of the black readings. Appendix B Image Reference Check_02 Description Primary version is shown below. The secondary version has reverse (black lines on white background). Check_11 Description Test In the primary version, the active video area is filled with alternating black and white pixels that form a very fine checkerboard, as shown below. The secondary version inverts the colors in the image. The inverted image looks almost the same as the non-inverted version. Verify monitor resolution 802BT/802R Video Test Generator User Guide 619 Purpose Method The resolution of your monitor should meet or exceed the design specifications. Adjust the brightness, contrast, and focus to their correct settings first. You should be able to see individual and distinct pixels in each of the boxes. Failure to see distinct pixels may indicate you have a defective video amplifier, focus correction circuit, or picture tube. Note: If multi-colored areas appear on a mask-type color picture tube, you may have a problem with convergence, or you may be exceeding the resolution of the picture tube. CirclesL 620 Description Special test image developed per customer specifications. In the primary version (shown below), the image consists of five large white circles on a black background. The circles are positioned in the center and in the corners of the active video area. The secondary version inverts the image to black circles on a white background. Purpose This pattern is specified by some monitor manufacturers for checking and adjusting video scan size, linearity, and over scanning. Appendix B Image Reference CirclesS Description Special test image developed per customer specifications. In the primary version (shown below), the image consists of eight small white circles on a black background. The circles are positioned in the corners of the active video area and centered on each edge of the active video area. The secondary version inverts the image to black circles on a white background. Purpose This pattern is specified by some monitor manufacturers for checking and adjusting video scan size, linearity, and over scanning. ColorBar Description The primary version (shown below) has 16 full-height vertical color bars. The secondary version splits the field into a top and bottom half. The bars in the bottom half of the screen are in reverse order. 802BT/802R Video Test Generator User Guide 621 Note: When outputting digital video, 33% Gray changes to 50% Gray, and 67% Gray becomes either Black or some gray level depending on how the display interprets the video information. Test Purpose Method 622 Verify that all video channels are functional To verify that none of the video channels are bad or connected incorrectly. Compare the sequence of color bars with the table. Missing bars may indicate a dead or unconnected channel. The transition between the bars should be sharp and distinct. Each bar should also be uniform in color and intensity across its entire width. Non-uniformity may indicate problems with the response of the video amplifiers. If all the bars are present but in the wrong order, one or more inputs may be swapped. Appendix B Image Reference ComFocus Description Special test image developed per customer specifications. Description This is an animated image consisting of one small multicolored cube orbiting around a larger multicolored cube. Each cube also is spinning on its own axis. The default text string is Quantum Data, which can be changed using commands. The primary version (shown below) has a black background and a thick green border. The secondary version uses a white background. Cubes Purpose Can be used for show demonstrations with your own text. 802BT/802R Video Test Generator User Guide 623 Custom Description This image has a white border around the active video, a centered smaller yellow box, and green diagonals. Purpose This image is an example of some of the available drawing primitives. It is not intended to be an image suitable for testing or adjusting a display. Rather, it can be used as a starting point for developing a custom image of your own. DeltaErr Description 624 Use with analyzer to test for flickering pixels in a static image. For more information, see “Measuring pixel errors” on page 123. Appendix B Image Reference Diamond1 Description Special test image developed per customer specifications. Dot1606, Dot1610, Dot1612, Dot1615, Dot1812, Dot1815, Dot2016 Description The primary version has white pixel dots on a black background. The secondary version has black pixel dots on a white background. The primary version of the Dot2016 image is shown below. 802BT/802R Video Test Generator User Guide 625 Dot_10, Dot_12, Dot_24 Description The active video area is filled with multiple rows of white, single pixel dots. The dots define the corners of what would appear to be square boxes if all connecting pixels were lit. The number of rows of boxes and the number of boxes per row depends on which version of the image is selected and the screen aspect ratio of the currently-loaded format. The number in the image’s name refers to the number of boxes that will be formed along the minor axis for most aspect ratios. The generator calculates the ratio and then finds the closest match from the following table. Aspect Ratio Dot_10 Dot_12 Dot_24 W:H Decimal Number of Rows Boxes per Row Number of Rows Boxes per Row Number of Rows Boxes per Row 16 : 9 1.777 É 10 16 10 16 18 32 5:3 1.666 É 10 16 10 16 18 30 4:3 1.333 É 10 14 12 16 24 32 1:1 1.000 10 10 12 12 24 24 3:4 0.750 14 10 16 12 32 24 The primary version has white pixel dots on a black background. A secondary version has black pixel dots on a white background. The primary version of the Dot_24 image is shown below. Purpose 626 To accurately produce an image on a color monitor, the three electron beams in the CRT must meet (converge) at the same location at the same time. Small dots displayed on a misconverged monitor appear as a group of multi-colored dots. Appendix B Image Reference Method The convergence adjustments of most color monitors fall into two main categories. The first set of adjustments, usually called Static Convergence, aligns the three beams in the center of the display. This method involves turning on all three guns and adjusting the various magnets on the convergence assembly to produce all white dots in the center of the display. The convergence assembly is located on the neck of the CRT. Different monitors and CRT types may each require their own magnet-adjustment sequence. After the center of the display is properly converged, the outer areas are adjusted by using the monitor’s Dynamic Convergence controls. The number of controls, the area of the screen they affect, and their adjustment procedure depends on the monitor under test. Test Purpose Method Focus adjustments An out-of-focus monitor displays fuzzy pixels which, in turn, result in poorly formed and hard-to-read characters. On monitors with a single (static) focus adjustment, adjust the control for the best average focus over the entire screen. The focus at certain locations should be within specified limits. Some monitors have a static and one or more dynamic focus controls. The sequence for adjusting them and the areas of the screen they affect depend on the monitor under test. DV_Swing Description This image is only available with DVI and HDMI. The DV_Swing image is used to temporally change the digital video swing (DVSS format parameter) between 90 and 1620 mVp-p of the HDMI and DVI digital output for the active format. This image displays the current video swing value over a graduated (ramp) background. This image is supported by HDMI boards (revision F or later), and DVI boards with FPGA F1 or later. 802BT/802R Video Test Generator User Guide 627 Note: The DVSC command can be used to set the swing value between 150 and 1500 mVp-p. Method To adjust the swing in 4 mV increments, press the Step key, then turn the Image knob. Press the Step key again to reset the digital swing value to the default value, which is 1000 mVp-p for all formats. Description This image has multiple versions that display different sizes of the same pattern. Version 0 is shown below. Dyna 628 Appendix B Image Reference EdidData Description Displays EDID from the display connected with the generator. For more information, see page 171. Description Special test image developed per customer specifications. This image has 19 versions. Elbit 802BT/802R Video Test Generator User Guide 629 EMITest1, EMITest2, EMITest3, EMITest4, EMITest5 Description Special test images used for electro-magnetic interference (EMI) testing of displays. The entire active video area is filled with an “H” character. The primary versions of these images draw white characters on a black background. The secondary versions draw black characters on a white background. The EMITest1 image is shown below. The EMITest2 image is the same as EMITest1, but with the bottom row of characters constantly drawn left-to-right and then cleared. The EMITest3 image is the same as EMITest1, but with a larger version of the “H” character. The EMITest4 image is the same as EMITest3, but with the bottom row of characters constantly drawn left-to-right and then cleared. 630 Appendix B Image Reference The EMITest5 image is shown below. FlashGry Description This image flashes a flat gray image at a high-frequency rate. The image flashed on the display is shown below. FlashRGB Description This image flashes RGB colors at a high frequency rate. 802BT/802R Video Test Generator User Guide 631 The image used as a background on the display is shown below. Flat, Flat07, Flat13, Flat20, Flat27, Flat33, Flat40, Flat47, Flat53, Flat60, Flat67, Flat73, Flat80, Flat87, Flat93, FlatGray, Flat_01, Flat_02, Flat_03, Flat_04, Flat_05, Flat_06, Flat_07, Flat_08, Flat_09, Flat_10, Flat_11, Flat_12, Flat_13, Flat_14, Flat_15, Flat_16 Description 632 The entire active video area is filled with a shade of gray. Each image displays a different shade of gray. The FlatGray image is shown below. Appendix B Image Reference Flat_B, Flat_G, Flat_R Description The screen is filled with blue (B), green (G) or red (R). The Flat_B image is shown below. Focus20 Description Primary version shown below. The secondary version has black characters on a white background. 802BT/802R Video Test Generator User Guide 633 FocusC14 Description Primary version shown below.The secondary version has black characters on a white background. FocusCCx Description 634 Primary version shown below. The secondary version has black characters on a white background. Appendix B Image Reference FocusEM Description Primary version shown below. The secondary version has black characters on a white background. FocusEMP Description Primary version shown below. The secondary version has black characters on a white background. 802BT/802R Video Test Generator User Guide 635 FocusM00 - FocusM15 Description The FocusM00 image is shown below. Focus_@6, Focus_@7, Focus_@8, Focus_@9 Description Test Purpose 636 In the primary versions, the screen is filled with white “@” characters on a black background. The secondary versions are drawn with black characters on a white background. The primary version of the Focus_@6 image is shown below. Focus adjustments An out-of-focus monitor displays fuzzy graphic images and poorly formed, hard-to-read text characters. Appendix B Image Reference Method On monitors with a single (static) focus adjustment, adjust the control for the best average focus over the entire screen. The focus at certain locations of the screen should be within specified limits. Some monitors have a static and one or more dynamic focus controls. The sequence for adjusting them and the areas of the screen that they affect depend on the monitor under test. Focus_Cx Description Test Purpose Method In the primary version (shown below), the screen is filled with white Cx characters on a black background. The secondary version is drawn with black characters on a white background. Focus adjustments An out-of-focus monitor displays fuzzy graphic images and poorly formed, hard-to-read text characters. On monitors with a single (static) focus adjustment, adjust the control for the best average focus over the entire screen. The focus at certain locations of the screen should be within specified limits. Some monitors have a static and one or more dynamic focus controls. The sequence for adjusting them and the areas of the screen that they affect depend on the monitor under test. 802BT/802R Video Test Generator User Guide 637 Focus_H Description Test Purpose Method In the primary version (shown below), the screen is filled with white H characters on a black background. The secondary version is drawn with black characters on a white background. Focus adjustments) An out-of-focus monitor displays fuzzy graphic images and poorly formed, hard-to-read text characters. On monitors with a single (static) focus adjustment, adjust the control for the best average focus over the entire screen. The focus at certain locations of the screen should be within specified limits. Some monitors have a static and one or more dynamic focus controls. The sequence for adjusting them and the areas of the screen that they affect depend on the monitor under test. 638 Appendix B Image Reference Focus_MM Description In the primary version (shown below), the screen is filled with white M characters on a black background. The secondary version is drawn with black characters on a white background. Focus_Oo Description Test In the primary version (shown below), the screen is filled with white Oo characters on a black background. The secondary version is drawn with black characters on a white background. Focus adjustments 802BT/802R Video Test Generator User Guide 639 Purpose Method An out-of-focus monitor displays fuzzy graphic images and poorly formed, hard-to-read text characters. On monitors with a single (static) focus adjustment, adjust the control for the best average focus over the entire screen. The focus at certain locations of the screen should be within specified limits. Some monitors have a static and one or more dynamic focus controls. The sequence for adjusting them and the areas of the screen that they affect depend on the monitor under test. Format Description A listing of the data contained in any format. The primary image lists the settings of the format driving the display. The secondary image can be used to list the contents of any stored format (via the Location field). This pattern works best at display resolutions of at least 640 pixel by 480 lines. FormatRx Description 640 Used by analzyer to view timing parameters measured from external signal. For more information, see “Measuring timing of video signal” on page 114. Appendix B Image Reference GenOps Description Provides key sequences and status of special operating modes. For more information, see “Special operating modes” on page 18. GenStats Description Provides detailed information about the generator. For more information, see “Displaying system information” on page 44. Geom_1 - Geom_5 Description The primary version of the Geom_1 image is shown below. Secondary version is drawn with black lines on a white background. 802BT/802R Video Test Generator User Guide 641 Gray25, Gray40 Description The Gray25 image is shown below. GrayBar Description Test Purpose 642 The primary version (shown below) has 16 full-height vertical graybars. The intensity of the bars is shown below. The secondary version splits the field into a top and bottom half. The bars in the bottom half of the screen are in reverse order. Video color tracking (color monitors) To verify that a color monitor accurately reproduces colors at all intensities. Appendix B Image Reference Method Perform the Brightness Control Adjustment and Brightness Uniformity tests first. Changes in brightness from bar to bar should be uniform. All of the bars should appear as an untinted gray at all levels. Test Purpose Method Video gain linearity (monochrome monitors) To check the video linearity (grayscale modulation) Perform the Brightness Control Adjustment and Brightness Uniformity tests first. Changes in brightness from bar to bar should be visible and uniform. GrayL1, GrayL3 Description The GrayL1 image is shown below. Grays5, Grays9, Grays11, Grays16, Grays32, Grays64 Description These images have the designated number of full-height vertical graybars. 802BT/802R Video Test Generator User Guide 643 The Grays11 image is shown below. GraysAll Description Contains 256 grayscale versions, from 0 (full black) to 255 (full white). Grill_11, Grill_15, Grill_22, Grill_33, Grill_44 Description 644 The entire active video area is filled with alternating black and white stripes. The stripes are drawn at different resolutions. Each of the stripes is four (4) pixels wide in the Grill_44 image and three (3) pixels wide in the Grill_33 image. Each of the stripes is two (2) pixels wide in the Grill_22 image and one (1) pixel wide in the Grill_11 image. Appendix B Image Reference The primary versions draw vertical stripes. The secondary versions draw horizontal stripes. The primary version of the Grill_44 image is shown below. Test Purpose Method Verify monitor resolution The resolution of your monitor should meet or exceed the design specifications. First adjust the brightness, contrast, and focus to their correct settings. You should be able to see individual and distinct stripes in all areas of the display at all four resolutions. Failure to see distinct lines at the highest resolution (Grill_11) may indicate you have a defective video amplifier or picture tube. Note: If multi-colored lines appear on a mask-type color picture tube, you may have a problem with convergence or you may be exceeding the resolution of the picture tube. 802BT/802R Video Test Generator User Guide 645 HalfArea Description Primary version shown below. Secondary version is drawn with black boxes and white background. HalfClk Description 646 Appendix B Image Reference Hat1606, Hat1610, Hat1612, Hat1615 Description Primary version of Hat1606 is shown below. Secondary version is inversed. Hat1606A, Hat1610A, Hat1612A, Hat1615A Description Primary version of Hat1606A is shown below. Secondary version is inversed. 802BT/802R Video Test Generator User Guide 647 Hat1812, Hat1815 Description Primary version of Hat1812 is shown below. Secondary version is inversed. Hat1812A, Hat1815A Description 648 Primary version of Hat1812A is shown below. Secondary version is inversed. Appendix B Image Reference Hat2016 Description Primary version is shown below. Secondary version is inversed. Hat2016A Description Primary version is shown below. Secondary version is inversed. 802BT/802R Video Test Generator User Guide 649 Hatch_6, Hatch_10i, Hatch_10o, Hatch_12i, Hatch_12o, Hatch_24i, Hatch_24o, Hatch_24s, Hatch_G, Hatch_M, GRN_HTCH, and MAGENTA Description The primary versions consist of a white, green (G and GRN), or magenta (M) crosshatch drawn on a black background. The lines form square boxes. A single pixel dot is located in the center of each crosshatch box. The number of boxes formed depends on the version of the image selected and the screen aspect ratio of the currently loaded format. The number in the image’s name refers to the number of boxes that are formed along the minor axis for most aspect ratios. The generator calculates the ratio and then finds the closest match from the table on the next page. Version names indicate the drawing method, as follows: • Versions ending in “i” draw from the inside (center) out. Any partial boxes are placed around the perimeter of the image. • Versions ending in “o” draw from the outside in. Any partial boxes are placed along the centerlines of the image. • Versions ending in “s” are the “i” version plus a 1-pixel thick border. The secondary versions invert the images to black lines and dots on a white background. Hatch_G, Hatch_M, GRN_HTCH and Magenta do not have secondary versions. The primary version of the Hatch_10i image is shown below. 650 Aspect Ratio Dot_10 W:H Decimal Boxes Vertically Boxes Horizontally Boxes Vertically Boxes Horizontally Boxes Vertically Boxes Horizontally 16 : 9 1.777 É 10 16 10 16 18 32 5:3 1.666 É 10 16 10 16 18 30 4:3 1.333 É 10 14 12 16 24 32 Appendix B Image Reference Dot_12 Dot_24 Test Aspect Ratio Dot_10 Dot_12 Dot_24 1:1 1.000 10 10 12 12 24 24 3:4 0.750 14 10 16 12 32 24 Convergence adjustment (color monitors only) Purpose To accurately produce an image on a color monitor, the three electron beams in the CRT must meet (converge) at the same location at the same time. Lines displayed on a misconverged monitor appear as several multi-colored lines, and the transitions between different colored areas contain fringes of other colors. Method The convergence adjustments of most color monitors fall into two main categories. The first set of adjustments, usually called Static Convergence, aligns the three beams in the center of the display. This method involves turning on all three guns and adjusting the various magnets on the convergence assembly to produce all white dots in the center of the display. The convergence assembly is located on the neck of the CRT. Different monitors and CRT types may each require their own magnet adjustment sequence. After the center of the display is properly converged, the outer areas are adjusted by using the monitor’s Dynamic Convergence controls. The number of controls, the area of the screen they affect, and their adjustment procedure depend on the monitor under test. Hatch_16, Hatch_20 Description The primary version of the Hatch_16 image is shown below. The secondary versions draw black lines on a white background. 802BT/802R Video Test Generator User Guide 651 Hatch20 Description Primary version...The secondary version draws black lines on a white background. Hatch4x3, Hatch5x4 and Hatch8x8 Description These are different versions of a crosshatch pattern that may be called for by some display manufacturers’ test procedures. The primary version consists of white crosshatch and circles on a black background. The secondary version inverts the image to black lines on a white background. The primary version of the Hatch4x3 image is shown below. Purpose 652 This is a general purpose test image that can be used to check and adjust video scan linearity and geometry and color convergence. Appendix B Image Reference Hatch64W Description This is a crosshatch pattern that may be called for by some manufacturers’ test procedures. The primary version (shown below) consists of an 8x8 white crosshatch on a black background. A white rectangular patch is added in the center. The secondary version inverts the image to black lines and box on a white background. Purpose Method This is a general purpose test image that can be used to check and adjust video scan linearity and geometry, and color convergence. The large white rectangle also allows for checking a display’s high voltage regulation. This is done by observing the vertical lines at the left and right edges of the image. They should be fairly straight and not pull in the area of the white rectangle. HdcpA1B1, HdcpA1B2, HdcpA2B1, HdcpA2B2, HdcpProd Description Used with HDCP feature. For more information, see Chapter 11, “Testing HDCP.” 802BT/802R Video Test Generator User Guide 653 Hitachi1 Description Special test image developed per customer specifications. The image consists of a 2x2 cluster of Microsoft Windows® screen simulations using Japanese characters. HSVnRGB Description 654 Appendix B Image Reference Imex1 Description InFocus1 Description Special test image developed per customer specifications. 802BT/802R Video Test Generator User Guide 655 InFocus2 Description Special test image developed per customer specifications. KanjiKAN Description Test 656 In the primary version (shown below), the screen is filled with white Japanese Kan characters on a black background. The secondary version is drawn with black characters on a white background. Focus adjustments Appendix B Image Reference LGLCDTVB, LGLCDTVG, LGLCDTVR, LGLCDTVW Description Special test image developed per customer specifications. Each image has three versions. The primary version of the LGLCDTVB image is shown below. LGRamp Description Special test image developed per customer specifications. The image provides a grayscale of two objects. The secondary version of the LGRamp image is shown below. 802BT/802R Video Test Generator User Guide 657 Linearty (Linearity) Description This image has three parts. The first part consists of six (6) white circles. A large circle is drawn in the center of the screen. Its diameter equals the lesser of the video height or width of the display. A smaller circle is drawn at half the diameter and concentric with the larger circle. A circle also is drawn in each of the corners of the screen. The diameter of the corner circles equals one-fifth of the display width. The second part of the image consists of a white crosshatch. The number of boxes in the crosshatch depends on the physical size of the display. The last part of the image consists of white tic marks on the horizontal and vertical center lines of the image. The marks are one pixel thick at every other pixel location. Every fifth mark is slightly longer. The color of the pattern can be changed with the individual video output controls. Test 658 Linearity adjustment Purpose To present an undistorted display, the horizontal and vertical sweeps of the electron beam across the face of the CRT should be at uniform speeds. Any non-uniformity in the sweep causes portions of an image to stretch while other portions are compressed. Non-linearity in a monitor shows up in several ways. It may be present across the entire screen, in a large portion of the screen, or localized in a very small area. Method The circles in the image can be used to do a general adjustment of a monitor’s linearity controls. Adjust the controls to form perfectly round circles. The crosshatch image can be used to measure linearity and to make finer control adjustments. All the full boxes in the crosshatch should be identical in size. Measure them with a ruler or a gauge made for the monitor under test. Any deviation should be within your specification limits. Use the tic Appendix B Image Reference marks and a ruler or gauge to measure linearity over a small portion of the display. Compare the number of tic marks per unit of measure with an adjacent or overlapping area. LinFocus Description This image has several parts. The first part consists of a large circle in the center of the screen. Its diameter equals the lesser of the video height or width of the display. The second part is a 10x10 box crosshatch. The crosshatch is drawn in from the outside edges, with any extra pixels in the boxes placed along the vertical and horizontal axis. The vertical centerline is two pixels thick if the format has an even number of active pixels per line. The horizontal centerline is two pixels thick if the format has an even number of active lines per frame. A smaller box is added at the center of the image. The box is one-half the height and two-fifths the width of one of the crosshatch boxes. Current format data is shown in the lower left quadrant of the image. It shows the number of active pixels (H) and lines (V) as well as the vertical and horizontal scan rates. The primary version (shown below) consists of a white pattern on a black background. The secondary version has a black pattern on a white background. The image also includes blocks of focus-checking characters at various locations. The blocks are positioned inside the crosshatch boxes and are up to 3x3 characters in size. The size of the blocks is limited by the number of characters that can fit in one box. Test Method Test Linearity adjustment Please see the Linearity test image on “Linearty (Linearity)” on page 658 for information on measuring linearity. Focus adjustment 802BT/802R Video Test Generator User Guide 659 Purpose Method An out-of-focus monitor displays fuzzy graphic images and poorly formed, hard-to-read characters when text is displayed on the screen. On monitors with a single (static) focus adjustment, adjust the control for the best average focus over the entire screen. The focus at certain locations of the screen should be within specified limits. Some monitors have a static and one or more dynamic focus controls. The sequence for adjusting them and the areas of the screen they affect depend on the monitor under test. Master Description 660 Appendix B Image Reference MoireX, MoireX33, MoireY, MoireY33 Description The MoireX and MoireY images consist of black lines on a white background across the active video area. MoireX provides vertical lines; MoireY provides horizontal lines. The MoireX image is shown below. The primary version of the MoireX33 and MoireY33 images provide a black frame around the black lines. The secondary version draws a white frame around black lines. The primary version of the MoireX33 image is shown below. 802BT/802R Video Test Generator User Guide 661 Monoscop Description MSony7, MSony8 Description 662 Special test image developed per customer specifications. Primary version of the MSony7 image is shown below. The secondary version draws white boxes and characters with a black background. Appendix B Image Reference MulBurst Description Orion Description This image provides a color bar that rotates (shifts) the bars to the right on an incremental basis. The color bars are shifted to the right at 3 second intervals. After pressing the Step key, turn the Image knob to adjust the interval between 3, 10, 30 and 60 seconds. Outline0, Outline1, Outline2, Outline3 802BT/802R Video Test Generator User Guide 663 Description The primary version of the Outline0 image consists of a rectangular white border on a black background. The border is one (1) pixel wide and defines the active video area. Two (2) diagonal lines join the opposite corners. A-full size cross is centered in the image. The horizontal line of the cross is one (1) pixel thick for formats with an odd number of active lines and two (2) pixels thick for formats with an even number of active lines. The vertical line of the cross is one (1) pixel thick for formats with an odd number of active pixels per line and two (2) pixels thick for formats with an even number of active pixels. The secondary version of these images draw black lines on a white background. In the Outline1 version, the two diagonal lines are removed and short marker lines are added to the border lines near to where the cross lines meet the border lines. The markers appear at both sides of the cross lines. The distance between the marker lines and the cross lines is the greater of either two (2) pixels or one (1) millimeter. 664 Appendix B Image Reference In the Outline2 version, the two diagonal lines are removed and short marker lines are added to the corners, and where cross lines meet and end. In the Outline3 version, the two diagonal lines are removed, cross lines are shortened, and short marker lines are added. Test Purpose Method Yoke tilt correction The horizontal axis of a displayed image should line up with the horizontal axis of your monitor. Any tilt is likely due to the yoke being rotated on the neck of the CRT. A rotated yoke makes any displayed image appear rotated. Place your monitor on a flat surface so the face of the CRT is perpendicular to the surface. Use a ruler or gauge to measure the height of each end of the image’s horizontal center line from the surface. The difference between the two readings should be within 802BT/802R Video Test Generator User Guide 665 specification for the monitor. If it is out of specification, the yoke must be adjusted. Loosen the hardware that clamps the yoke to the neck of the CRT and rotate the yoke until the line is horizontal. Tighten the yoke-clamp hardware. Test Purpose Method Test Yoke winding orthogonality check The horizontal and vertical deflection coils on the yoke should have their axes cross at exactly 90 degrees. Improper orientation of the windings causes displayed rectangles to look more like nonorthogonal parallelograms. This type of defect is almost impossible to correct with adjustments. It is usually easier to replace the defective yoke. First, perform the yoke tilt correction described above. The vertical center line of the image should be perpendicular to the work surface. If the deviation is beyond specification, the monitor should be rejected and sent back for repair, rather than trying to magnet a defective yoke. Display size correction Purpose A too-large active video size adjustment on a monitor may cause information to be lost around the edges of the screen. A too-small active video size adjustment may make some displayed information hard to read. The correct size is needed to obtain the correct aspect ratio. You need the correct aspect ratio to get round circles and square squares. Method First, determine the correct physical size of the active video area for the display. This information usually is given in a display’s specification sheet or service manual. The size should match the sizes in the format you are using. The size setting of the current format can be checked using the Format test image. Place a ruler or gauge along the horizontal line of the image and adjust the monitor's horizontal size control until the distance between the end points matches the specified value. Move the ruler or gauge to the vertical line and adjust your monitor's vertical size control until the distance between the end points matches the specified value. Test Purpose 666 Parallelogram distortion check Parallelogram distortion is very difficult to correct with magnets because the correction often causes barrel distortion. Therefore, you should decide early whether your monitor meets this specification. The problem usually can be traced to the improper winding of the yoke coils. If the problem is not too severe, it may be corrected by adding or adjusting magnets on the yoke. However, if the distortion is excessive, it may be an indication of a defective yoke which cannot be corrected with magnets. Appendix B Image Reference Method Measure the lengths of the two (2) diagonal lines. Any difference is an indication of parallelogram distortion. The difference in readings should be within the specifications of the monitor. If the difference in the readings is too far beyond specification, the monitor should be rejected and sent back for repair, rather than trying to magnet a defective yoke. Test Trapezoid distortion correction Purpose This image gives you a way to measure trapezoid distortion in your monitor. If the distortion is not too severe, you may be able to correct it by adding or adjusting magnets on the yoke. Method Perform the yoke winding orthogonality check and parallelogram distortion check first to avoid wasting time on a monitor with a defective yoke. Measure the width of the image at the top and bottom of the display. Any difference in readings should be within the specification limits. Measure the height of the image at both sides of the display. Again, any difference in readings should be within specification limits. If either of the differences is out of specification, the trapezoid distortion of the monitor is out of specification. Add or adjust magnets on the yoke to correct the problem. The pin and barrel distortion correction should be repeated to make sure that it is still in specification. Test Pin and barrel distortion correction Purpose If perfectly linear sweep signals are sent to a perfectly wound deflection yoke mounted on a perfect CRT, you would not necessarily get a perfectly formed raster. Instead you would likely get a raster that had its corners stretched away from the center, resembling a pin cushion. This distortion occurs because the geometry of the deflected electron beam does not match the geometry of the tube face plate. Also, imperfections in the yoke or CRT may affect this problem. In some cases one or more corners may be pulled towards the center of the raster causing it to look like a barrel. Uncorrected raster distortion carries over as distortion of the displayed image. Method A slot gauge may be used to determine if the amount of pincushion or barrel distortion is within limits. A basic slot gauge may consist of a piece of opaque film with at least two (2) transparent slots in it. One slot is used for top and bottom distortion and the other is used for the sides. By positioning the correct slot over each portion of the border line, the entire line should be visible. If this cannot be done at all four sides, the monitor requires correcting. 802BT/802R Video Test Generator User Guide 667 There are two main ways of correcting pincushion distortion. The first involves placing or adjusting magnets on the yoke. This is a trial-and-error method. However, skilled operators develop a feel for how strong a magnet to use and how to place it in order to get the desired correction. If any correction is performed, the trapezoid distortion correction should be repeated. The other correction method involves adding correction signals to the deflection signal driving the yoke. This method is usually found in color monitors, where adding magnets to the yoke would cause problems with convergence and purity. The type and number of adjustments depends on the monitor being tested. P1 Description 668 This image is a 6x6 white crosshatch without a border on a black background. Appendix B Image Reference P2 Description This image is a 4x4 white crosshatch with a border on a black background. Description This image is a 4x4 white crosshatch with a border and a small, centered white patch on a black background. P3 802BT/802R Video Test Generator User Guide 669 P4 Description This image is an 8x8 white crosshatch with a border on a black background. Description This image is an 8x8 white crosshatch with a border and a small, centered white patch on a black background. P5 670 Appendix B Image Reference P6 Description 16x12 pixel white crosshatch with a border on a black background. P6_Sony Description 6x12 pixel white crosshatch with a border on a black background. 802BT/802R Video Test Generator User Guide 671 P7 Description 16x12 white crosshatch with a border and a small, centered white patch on a black background. Description This image is an all black active video area. The secondary version draws an all white video area. P8 672 Appendix B Image Reference P9 Description This image is an all white active video area. The secondary version draws an all black video area. Description Special test image developed per customer specifications. There are four versions of this image. P10 After pressing the Step key, turn the Image knob to select up to 4 different versions of this image. 802BT/802R Video Test Generator User Guide 673 PacketRx Description Displays the InfoFrame data received by HDMI receiver. For more information, see “Testing HDMI transmit device InfoFrame capability” on page 127. PacketTx Description Displays the InfoFrame data transmitted from the HDMI transmitter. For more information, see “Viewing InfoFrame contents” on page 161. PdsCrt1 Description 674 Special test image developed per customer specifications. Appendix B Image Reference PdsCrt2 Description Special test image developed per customer specifications. Persist Description In the primary version, 15 small white boxes move back and forth between diagonal guide lines. The lines form 15 side-by-side tracks. The size of each box is scaled to the light meter box size set by the MSIZ system parameter. The image does the following: • The box in the center track (marked “1X”) moves one scan line vertically and one pixel horizontally for each vertical frame of refresh. • The seven boxes to the right of the center track (marked “2X” through “8X”) move 2, 3, 4, 5, 6, 7, and 8 pixels and lines per frame, respectively. • The seven boxes to the left of the center track (marked “/2” through “/8”) move one scan line vertically and one pixel horizontally for every 2, 3, 4, 5, 6, 7, and 8 vertical frames of refresh, respectively. These boxes are at the bottom of the tracks. In cases where the next move would cause the box to move beyond the end of its track, it immediately reverses and moves the correct distance in the opposite direction for the next frame. A continuously-running counter appears in the upper left corner of the image. The number shown is the number of vertical frame refreshes that have occurred since the generator was first powered up. The secondary version draws a black image on a white background. 802BT/802R Video Test Generator User Guide 675 An example of the primary version of the Persist image is shown below: Test Phosphor persistence Purpose The phosphors on the face of most CRTs continue to glow for a short period of time after the electron beam has stopped energizing them. This phenomenon is called persistence. A certain amount of persistence is desirable in most applications. It prevents a flickering of a displayed image that most users would find objectionable. On the other hand, a CRT with an overly long persistence time causes moving objects to leave a blurred trail. Method A flickering in the slower moving boxes indicates that the combination of refresh rate and phosphor persistence is not suitable for long-term viewing. A fading tail left behind by the faster moving boxes indicates that the display may not be suitable for viewing animated images. 676 Appendix B Image Reference PgBar64H, PgBar64V Description Special test image developed per customer specifications. The PgBar64H image is shown below. PgCB, PgCG, PgCR, PgCW, PgCWrgb Description Special test image developed per customer specifications. Primary version of PgCB is shown below. The secondary versions draw all white over the last bar. 802BT/802R Video Test Generator User Guide 677 The PGCWrgb is shown below. Philips1 Description Special test image developed per customer specifications. PixelRep Description 678 Used to test HDMI pixel repetition. There are 10 different versions of this image to support the different pixel repetition settings. For more information, see “Testing HDMI video pixel repetition” on page 152. Appendix B Image Reference PRN24bit Description This image displays pseudo-random noise using 24-bits-per-pixel color depth. PRN_5, PRN_9 Description Used with analyer to verify the analyzer’s pseudo-random noise analysis capability. The PRN_5 image introduces 5 pixel errors per color component, while the PRN_9 image introduces 9 pixel errors per color component. For more information, see “Testing accuracy of analyzer” on page 120. The PRN_5 image is shown below. ‘ PulseBar Description This image is intended for TV formats, but can be displayed with any format up to 100 MHz. The image looks like two vertical lines followed by a wide vertical bar on a display’s screen. The first line is a sine-squared modulated pulse that fades from black to red and 802BT/802R Video Test Generator User Guide 679 back to black. The pulse is 20 T for PAL and 12.5 T for NTSC formats. The second narrower line is a 2 T white sine-squared pulse. T = 100 nSec for PAL and 125 nSec for NTSC formats. The wide bar is white with sine-squared edges. Test Video system testing This multi-purpose pattern can be used with other instruments to check television K factors. The modulated pulse can be used to check chrominance-to-luminance delay and gain. The narrow white line can be used to measure short term linear distortion (K2T). 680 Appendix B Image Reference QuartBox Description Test Purpose Method Notes The primary version (shown below) has a single white box in the center of active video. The size of the box is one-half the width and height of the active video area (a quarter of the entire active video area). The secondary version draws a black box on a white background. Brightness control adjustment The wrong brightness setting on your monitor may cause other tests such as Contrast, Focus, and Beam Size to be invalid. An accurate brightness setting helps give repeatable measurements throughout other tests. This version of the brightness box should be used if the display’s specifications call for the brightness to be set with one-fourth of the screen lit. Place your light meter probe within the center box and adjust the monitor’s brightness control to obtain the required light meter reading. The color of the center box is a special color, named foreground. The FRGB command can be used to change the default color of foreground to any RGB value. IMGL quartbox: ALLU FRGB 122 122 122 // loads QuartBox image // sets RGB color of box After loading a different format, send the FRGB command again to set the box fill color. If you want to draw your own box, use foreground as the fill color, and then use the FRGB command to define the color of “foreground.” For example: IMGL RECT FRGB FRGB raster; ALLU // clears display foreground 100 100 100 100 dither100 128 128 0 192 192 64 802BT/802R Video Test Generator User Guide 681 FMTL DMT0660; ALLU FRGB 192 192 64 Ramp Description This image provides an active video area starting from full black (+7.5 IRE) at one edge of the screen to full white (+100 IRE) at opposite end of the screen. There are 4 versions of this image—one for each edge of the display. When selected, this image is displayed. After pressing the Step key, turn the Image knob to change the image starting point to left, right, top, or bottom. RampX Description 682 This image provides a ramp image that continuously sweeps (moves) to the right on an adjustable time basis. Appendix B Image Reference When selected, this image is displayed. After pressing the Step key, the image moves to the right. Adjust the speed using the Image knob (turn clockwise to slow down the image). Ramp_B, Ramp_G, and Ramp_R Description Test Method The active video area goes from full black (+7.5 IRE) at the left edge of the screen to full blue (_B), green (_G), or red (_R) at the right edge. The Ramp_B image is shown below. Video gain linearity When viewed on a TV screen, the full range of grays should be visible. There should be no color shifts visible. 802BT/802R Video Test Generator User Guide 683 Raster Description Test The primary version shows a totally black display (nothing being displayed). The secondary version shows a totally white display. Raster centering Purpose Many monitor applications require that the displayed image or text fit completely within a bezel that surrounds the CRT. This usually requires that you first center the blank raster on the face of the CRT, and then center the image within the raster. Use this image for centering the raster on the CRT. Method Turn up your monitor’s brightness control until the raster is just visible. Adjust the raster’s position and size using the size and raster centering controls. The raster centering adjustment for many monochrome monitors consists of moving magnetic rings on the deflection yoke. Regulate Description 684 The image cycles between two (2) patterns. In the primary version, the first pattern is a white outline that defines the edges of displayed video. The other pattern has the same outline plus a solid white rectangle in the center. The size of the solid rectangle equals 95% of the height and width of displayed video. The speed of the cycle cannot be changed. The secondary version has a thick white frame with a black center for the first pattern and a solid white active video area for the other pattern. Appendix B Image Reference The first pattern of the primary version is shown below. Test Method High voltage regulation The size of the border should not change for each half of the image. The change in border size between the two images should be within the specification limits of the monitor. Samsung1, Samsung2 Description Special test images developed per customer specifications. The image consists of three small simulations of Microsoft Windows® screens on a blue background (Samsung1) or black background (Samsung2). A border and centered cross are formed with repeating 802BT/802R Video Test Generator User Guide 685 groups of the characters “e” and “m”. The repeating characters are also used to form a rectangular patch in the upper left hand corner and a circular area in the center of the image. The secondary version of Samsung2 draws a white background. Samsung3 Description 686 Special test image developed per customer specifications. Appendix B Image Reference Samsung4 Description Special test image developed per customer specifications. Samsung5 Description Special test image developed per customer specifications. Samsung6 Description Special test image developed per customer specifications. 802BT/802R Video Test Generator User Guide 687 SamsungB Description Special test image developed per customer specifications. SamsungT Description 688 Special test image developed per customer specifications. There are four versions of this image. When selected, the following image is displayed. Appendix B Image Reference SlideBox Description This image displays a 16x9 white crosshatch with a large white patch moving across the screen. To change the animation speed: 1. Load the SlideBox image. 2. Establish a terminal session with the generator (see page 14). 3. Enter the following commands: ISUB IVER IMGU DELX IMGU DELX IMGU 1 1 10; 20; 802BT/802R Video Test Generator User Guide 689 SlideX Description This image displays a black background with a large white vertical bar moving across the screen. After pressing the Step key, the speed of vertical bar movement can be increased by turning the Image knob (turn clockwise to speed up image). To change the animation speed using the command-line interface: 1. Establish a terminal session with the generator (see page 14). 2. Load the SlideX image. 3. Enter the following commands: ISUB IVER IMGU DELX IMGU DELX 1 1 10; 20;IMGU SMPTE133 Description 690 This image is based on a recommended practice (RP-133) test pattern designed by the Society of Motion Picture and Television Engineers (SMPTE). The original application was used in testing and evaluating medical imaging monochrome displays. The image now is Appendix B Image Reference used in many different display applications. The image is self-scaling as to the number of active pixels and active lines used. Some of the image’s elements have minor differences from the original SMPTE specification. These differences are noted in descriptions of the individual elements. • The image is drawn on a reference background having a 50% intensity level. The background covers the entire active video area. • Crosshatch – There are 10 boxes vertically. The number of horizontal boxes is based on the physical aspect ratio determined by the HSIZ and VSIZparameters in the currently loaded format. The boxes are perfectly square with any fractional spaces placed around the outside edges of the image. The vertical lines are two (2) pixels thick while the horizontal lines are two (2) scan lines thick. Small crosses indicate the intersection of the horizontal and vertical lines when they are covered by other parts of the image. All parts of the crosshatch are normally drawn using a 70% intensity level. A 75% level is used in the secondary version. • Resolution patch – The patch is made up of six (6) smaller boxes that are each about 6.25% of the height of the display. The boxes are made of alternating intensity (0 and 100%) stripes. The stripes run vertically and horizontally. The stripes may be one (1), two (2) or three (3) pixels wide each. Details of the patch are shown in the lower half of the following illustration. The patches are located in each corner of the main image and in the center. They are oriented with the highest resolution and contrast boxes closest to the outside corners. The 48%-53%, 48%-51% and 50%-51% level patches are omitted in the secondary version. • Grayscale boxes – Twelve (12) boxes at eleven (11) intensity levels are clustered around the center of the main image. They start at 0% and increase in 10% steps to 802BT/802R Video Test Generator User Guide 691 100% with two (2) boxes at a 50% level. All of the grayscale boxes are omitted in the secondary version. • Gamma check dither box – A small box is drawn inside the right-hand 50% grayscale box. The box is half the width and height of the larger box. The box consists of a checkerboard of alternate one-on and one-off pixels. The alternate pixels have levels of 0 and 100%. This smaller box is not part of the original SMPTE specification and is omitted in the secondary version. • Contrast boxes – Two (2) boxes are drawn adjacent to the grayscale boxes. They are at 0 and 100% levels. There are smaller boxes drawn inside each box at 5 and 95% levels. The contrast boxes are omitted in the secondary version. • Black and white windows – Two (2) horizontal bars are located above and below the grayscale boxes. Their height equals 8% of the display height. There are half-size bars centered in the larger bars. In the primary version, the dark portion of the windows is at a 5% level and the bright portion is at a 95% level. Zero and 100% levels are used in the secondary version. • Border – A border line is drawn around the image. It is set in from the edges of displayed video a distance equal to 1% of the displayed height and has a thickness equal to 0.5% of the displayed height. The intensity level is the same as that of the crosshatch lines. • Circle – A large circle is centered in the image. It touches the top and bottom of the active video area when the aspect ratio is wider than it is high (landscape-type display). The circle touches the left and right sides of active video when the aspect ratio is taller than it is wide (portrait-type display). The intensity level is the same as that of the crosshatch lines. The circle is not part of the original SMPTE specification. • Resolution data - The number of active pixels per line and the number of active lines is shown as text below the lower black and white window. The pixel depth also is shown. The intensity level of the text is the same as that of the crosshatch lines. The displaying of the data is not part of the original SMPTE specification. The secondary version adds a row of six (6) color bars above and below the black-and-white windows. The order of the colors, from left to right, is red, green, blue, cyan (g+b), magenta (r+b) and yellow (r+g). The top row is drawn at 100% intensity levels and the bottom row is drawn at 50% intensity levels. Color bars are not part of the original SMPTE specification. Test Method 692 Deflection linearity If the overall height and width of the display’s active video area match the sizes in the format, the large circle should be perfectly round. Each box in the crosshatch pattern should be the same size and shape. For more information on testing linearity, refer to the Linearty test image on page 658. Appendix B Image Reference Test Method Test Method Test Method Test Method Test Method Test Method Test Method Test High contrast resolution All the 0 and 100% level stripes in all the resolution patches should be separate and distinct. Low contrast resolution and noise All the mid-level 2 on - 2 off stripes in all the resolution patches should be visible and distinct. This is a sensitive test for noise in the display’s video amplifiers. Quick gamma check The average brightness level of the small gamma dither box should match the brightness of the larger surrounding box. This is a visual check to see if the display’s gamma correction is producing the correct mid-level response. Video gain linearity and gamma The individual grayscale boxes all should be at their indicated levels. A small aperture photometer is usually required to get accurate and repeatable readings. Contrast and brightness check On a display with properly adjusted brightness and contrast controls, both the 5% and 95% contrast boxes should be clearly visible inside their larger surrounding 0% and 100% boxes. Video amplifier stability The two black-and-white windows should show sharp transitions between the smaller box and the surrounding window. Streaking may be an indication of undershoot or overshoot while ghost images may indicate a ringing problem. Excessive overscan and off-center alignment The entire border should be clearly visible on the face of the tube and not be hidden by the edge of the glass or by any bezel. Interlace flicker 802BT/802R Video Test Generator User Guide 693 Method The horizontal 1 on - 1 off stripes in the resolution boxes should not have objectionable flicker when shown with an interlaced format. Excessive flicker indicates that the combination of the display’s CRT persistence and frame scan rate is below the persistence time of the human eye. SMPTEbar Description This image is based on an engineering guideline (EG1-1990) test signal specified by the Society of Motion Picture and Television Engineers (SMPTE). The SMPTE pattern, in turn, is derived from an EIA standard test pattern (RS-189-A). The image, is set up to be generated by an 801GX generator as an encoded TV output. It is designed for adjusting the color settings of a television monitor by eye. It can also be used with a TV waveform analyzer and vectorscope for testing video signal processors and color decoders. The image is available on all models as a component RGB signal. Some of the image’s elements have some differences from the original SMPTE specification. These differences are given in descriptions of the individual elements. 694 • The upper 67% of the image consists of a series of color bars. These bars match the order of the bars in the SMPTE and EIA patterns. They are similar to the 801GX’s TVBar_75 image without the last black bar. • The left side of the lower 25% of the image contains isolated -I and Q color difference signals that match the original EIA and SMPTE patterns. The -I signal appears as a bluish-gray bar and the Q signal appears as a purple bar on a TV monitor. The bars are separated by a white (+100 IRE) bar. • The right side of the lower 25% of the image contains a narrow 12.5 IRE gray bar. Due to a hardware limitation on the 801GX, this portion of the pattern does not match the original EIA and SMPTE patterns. The original patterns had +3.5 (blacker than black) and +11.5 IRE bars separated by a +7.5 IRE (black) bar. Appendix B Image Reference • Test The remaining central 8% of the image contains a row of chroma set bars. These bars are part of the SMPTE pattern but are not in the EIA pattern. The order of the alternating color and black bars matches those in the SMPTE pattern. Color video performance Purpose This general purpose pattern can be used to check the video handling capabilities of most parts of a television system. Method When viewed on a TV screen, all of the upper color bars should be correct and in the order shown. The hue and intensity of each bar should be uniform over the entire bar. The image can be used with a TV waveform analyzer to check the performance of a video system. The upper color bars, as they would appear on a waveform analyzer, are shown on a previous page. Test Color decoder performance Purpose The image can used with a TV vectorscope to check for proper operation of a video color decoder. Vectorscope signatures of the upper and lower portions of the image using NTSC encoding can be found on the previous page. Method The vectorscope signature for the color bars should hit the target test point for each color on the vectorscope’s graticule. If you are using PAL encoded video, the signature will be similar to the one shown for the TVBar_75 test image on page page 702. The three “legs” of the vectorscope signature for the -I and Q color difference signals should match the Burst, -I and Q reference lines on the vectorscope’s graticule. The following tests are based on the original SMPTE guideline: 802BT/802R Video Test Generator User Guide 695 Test Method Visual chroma gain adjustment To perform this test, you must have a way of turning off the red and green guns in the monitor under test. Turning off the red and green video components of the 801GX generator’s video output will not work for this test. This test uses the upper and central color bars. Switch off the red and green guns on the monitor. This will produce four blue bars, separated by black bars. Adjust the chroma gain so that the brightness of each outer blue bar is uniform over the entire bar. The gain is correct when the bottom 10% of each bar is the same brightness as the rest of the bar. Test Method Visual chroma phase adjustment In order to perform this test, you must have a way of turning off the red and green guns in the monitor under test. Turning off the red and green video components of the 801GX generator’s video output will not work for this test. This test uses the upper and central color bars. Switch off the red and green guns on the monitor. This will produce four blue bars, separated by black bars. Adjust the chroma phase so that the brightness of each of the two central blue bars is uniform over the entire bar. The phase is correct when the bottom 10% of each bar is the same brightness as the rest of the bar. Test Method 696 Visual black level adjustment This test uses the lower right hand portion of the image. Reduce the black level until the gray bar disappears. Slowly increase the black level until the bar just becomes clearly visible. Appendix B Image Reference Sony6 Description Special test image developed per customer specifications. Sony6WLC Description Special test image developed per customer specifications. 802BT/802R Video Test Generator User Guide 697 sRGBflat Description For testing color response per Microsoft’s WinColorKit standard. This standard was developed by Microsoft to standardize methods relating to the matching of colors appearing on various displays (go to http://www.microsoft.com/whdc/hwdev/tech/color/ColorTest.mspx for more details). There are 38 different versions of this image to support this feature. When selected, a flat image appears with a color that is remembered from the last time the image was set up. The example below shows version 8 (Red1) of the sRGBflat image: A small label in the upper left corner of the image indicates the Microsoft name for the color that is currently being displayed (for example, “sRGB-Gray5”). Note that some of the names that appear conflict with generator color names (for example, “sRGB-Gray5” is not the same as the generator color “Gray5”). After pressing the Step key, turn the Image knob to select up to 38 different versions of this image. Each image displays another WinColorKit color. Note: For more information of generator support for Microsoft WinColorKit, go to http://www.quantumdata.com/support/kb/article.asp?kbid=100152. Staircas, Stairs20 Description 698 The active video area goes from full black at the left edge of the screen to full white at the right edge. There are six (6) steps (Stairs20) or sixteen (16) steps (Staircas). Appendix B Image Reference The Stairs20 image is shown below. Test Method Video gain linearity When viewed on a monitor’s screen, a black bar plus five (5) gray bars should be visible. There should be no color shifts, and each of the bars should be uniform in color. The image also can be used with an oscilloscope or TV waveform analyzer to check the gain linearity and gamma correction of a video system. Strokes0, Strokes1 Description This image may cited by some display manufacturers’ test procedures. The Strokes0 version consists of multiple groups of separated red, green and blue horizontal lines drawn on a black background. The Strokes1 version consists of multiple groups of separated red, green and blue diagonal lines drawn on a black background. 802BT/802R Video Test Generator User Guide 699 The Strokes0 image is shown below. Purpose These images are special-purpose test patterns used in test and alignment procedures specified by some display manufacturers. Text_9, Text_9T, Text_11, Text_12T, Text_16 Description In the primary versions, the screen is filled with random paragraphs of white text on a black background. The amount of text is determined by the size of the font used and the horizontal and vertical resolution of the format. The Text_16 image uses a larger font than the Text_9 image. The secondary versions use black text on a white background. The primary version of the Text_9 image is shown below. Test 700 Word processor simulation Appendix B Image Reference Purpose Method If your monitor is used in word processor workstations or other applications that call for large amounts of text to be displayed, you can use this image to simulate actual user conditions. Select a suitable font size and text color. Adjust your monitor’s brightness and contrast controls to obtain the best image. The characters in all areas of the display should be well formed and in focus. TintAlign Description Toshiba Description Special test image developed per customer specifications. There are two sub images, the secondary image is depicted below. The top half of the image has three small boxes (red, green, blue) with the upper left half at 92.7% luminence and the upper right half at 50% 802BT/802R Video Test Generator User Guide 701 luminence. There is a series of 11 small boxes of increasing luminence left to right with the luminence identified in text. The lower left quarter of the image is 28.5% luminence and the lower right is magenta at 44.3 IRE. TVBar100 & TVBar_75 (TV formats only) Description The image consists of seven vertical bars that fill the entire active video area. The color and order of the bars is shown in the figure below. The TVBar100 image has a peak video level of 100 IRE and the TVBar_75 image has a peak video level of 75 IRE. The TVBar100 image is shown below. Test 702 Color video performance Appendix B Image Reference Purpose This general purpose pattern can be used to check the video handling capabilities of most parts of a television system. Method When viewed on a TV screen, all of the colors should be correct and in the order shown. The hue and intensity of each bar should be uniform over the entire bar. The image can be used with a TV waveform analyzer to check the performance of a video system. Individual scan lines of each image, as they would appear on a waveform analyzer, are shown on the following page. The image is quite effective when used with a TV vectorscope to see how a video system handles an encoded color signal.The image consists of a white crosshatch on a black background. The lines form square boxes when the display’s active video area has a 4:3 aspect ratio. The vertical lines are made using sine-squared (2 T) pulses (T = 125 nSec for NTSC and T = 100 nSec for PAL). Test Convergence adjustment Purpose To accurately produce an image on a color monitor, the three electron beams in the CRT must meet (converge) at the same location at the same time. Lines displayed on a mis-converged monitor will appear as several multi-colored lines, and the transitions between different colored areas will contain “fringes” of other colors. Method The convergence adjustments of most color monitors can be divided into two main categories. The first set of adjustments, usually called “Static Convergence,” calls for aligning the three beams in the center of the display. This method involves turning on all three guns and adjusting the various magnets on the convergence assembly to produce all white lines and dots in the center of the display. The convergence assembly is located on the neck of the CRT. Different monitors and CRT types may each require their own magnet adjustment sequence. 802BT/802R Video Test Generator User Guide 703 After the center of the display is properly converged, the outer areas can be adjusted by using the monitor’s “Dynamic Convergence” controls. The number of controls, the area of the screen that they affect and their adjustment procedure is dependent upon the monitor under test. Test Sweep linearity adjustment Purpose To present an undistorted display, the horizontal and vertical sweeps of the electron beam across the face of the CRT should be at uniform speeds. Any non-uniformity in the sweep will cause portions of an image to be stretched while other portions will be compressed. Non-linearity in a monitor can show up in several ways. It may be present across the entire screen, a large portion of the screen, or it may be localized in a very small area. Method Adjust the display’s linearity controls so that all of the boxes in the crosshatch are identical in size. You can measure the boxes with a ruler or with a gauge made for the monitor under test. Any deviation should be within your specification limits. Taffeta Description TVoutLin Description 704 Equivalent to Outline1 image but it uses anti-aliasing for vertical bars and double horizontal lines, which reduces flickering. Appendix B Image Reference TVSplBar Description Special test image developed per customer specifications. 802BT/802R Video Test Generator User Guide 705 706 Appendix B Image Reference C Error Messages Topics in this appendix: • System errors • Format errors • Error code descriptions 802BT/802R Video Test Generator User Guide 707 System errors This section discusses system error messages that may be displayed by the generator from time to time. Power-on self test messages The integrity of the data stored in non-volatile memory is checked every time the generator is turned on. The following tests are performed: 1. The system configuration memory is checked. The memory remembers what the generator was doing when it was last powered down. The memory also stores all system wide parameters such as calibration factors and the light meter size. It is also checked to see if it is compatible with the current version of operating firmware. If everything is in order, then the generator goes on to step 2. Otherwise, a “System corrupt!” message is displayed for 2 seconds. This message is immediately followed by a “Memory blank” message, which is displayed for 2 seconds while the format memory is re-initialized. Memory initialization involves clearing the entire non-volatile memory and loading it with factory default data. Any and all data created or edited by the user will be wiped out. The calibration factors are restored to the original values used at the factory to test and calibrate the unit. The generator then continues with step 3. Note: System corruption is rare, and may be an indication of a bad memory backup battery or a damaged generator. Note: If you update the firmware EPROM in your unit, your system will appear to be corrupt at the next power-on. 2. The remainder of non-volatile memory is checked to see if any data has been corrupted since the last time the generator was used. This check includes each of the 300 format storage locations. All user created custom images and test sequences are also checked. If no problems are found, the generator goes on to step 3. If one (or more) items have been corrupted, a message containing a tally of the defective items is displayed for 2 seconds. A message for two corrupted items is shown here. Please note that the checking routine does not identify the types of items (format, 708 Appendix C Error Messages custom image or test sequence) that are corrupted. It is up to the user to check the contents of the individual items. Attempting to load a corrupted item will report and error for that item. A corrupted format can be repaired be either editing it or by downloading a new set of data from a computer. In most cases, a corrupted custom image or test sequence can not be repaired. This is due to the variable data structure used. You will need to recreate and save the data back into memory. Repeated corruption of the data in non-volatile memory usually indicates a weak battery. Battery replacement information can be found in the chapter on Maintenance. 3. A power-on message, indicating the current firmware and hardware revision levels, will appear for 2 seconds at the end of the self test procedure. If an animated image is displayed at power on, this message will not disappear until a button is pushed or a knob is turned. Power fail message Whenever the AC power line voltage dips below the minimum specified, this message is displayed and the generator’s microprocessor is halted. If you see this message during normal operation, it probably indicates that a power sag or short duration drop-out has occurred. To clear this condition, cycle the power going to the generator. If the power is good, the generator should resume normal operation. If you still have a problem, you may also want to check to see that the line voltage selector (next to the power inlet) is set correctly for the power being fed into the generator. 802BT/802R Video Test Generator User Guide 709 Format errors Under normal operating conditions, a properly programmed model 801GX generator should never report any Format error messages. If you do get an error message while loading a format it is for one of two reasons. The generator distinguishes between invalid data, entered in one of the programming modes, and corrupted data caused by a memory failure. In either case, the generator will shut all of its outputs off. The outputs remain off until a valid format is loaded. Invalid data error messages The example on the left shows a typical invalid data error message. The top line of the display shows the format’s storage location number and name. The bottom line shows the error number. Error numbers will be in the range of 2000 through 2999. Different numbers indicate what type invalid data or combination of data is causing the error. The following pages explain the cause of each of the error numbers and offers suggestions on how to correct the problem. Corrupt data error messages The example on the left shows a corrupted data error message. The top line of the display shows the format’s storage location number and name. The bottom line shows the error number. Error number 9450 identifies the cause of the error as corrupted data. This type of error either indicates the signs of a failing memory backup battery or a more serious hardware failure in the generator. Corrupted formats can corrected by either editing them or by downloading a clean copy of the format from a computer. The “Programming” chapter explains both methods in detail. 710 Appendix C Error Messages Error code descriptions 2000-2999 Format errors 2030 Number of fields per frame less than 1 A valid video format must have at least one (1) vertical filed of video per frame. 2040 Number of fields per frame greater than 2 The generator hardware configuration does not support interlaced video formats having more than two (2) vertical fields per frame. 2041 Can not repeat field if progressive Repeat field operation is only supported in interlaced video formats. 2050 Horizontal total too small The video format’s total (active + blanked) number of pixel clock cycles per horizontal scan line is below the minimum number supported by the generator hardware configuration. 2060 Horizontal total too large The video format’s total (active + blanked) number of pixel clock cycles per horizontal scan line is greater than the maximum number supported by the generator hardware configuration. 2071 Pixel rate too high The video format’s total (active + blanked) number of pixel clock cycles per horizontal scan line multiplied by the horizontal scan rate exceeds the maximum pixel clock frequency supported by the generator hardware configuration for the format’s video type. 2072 Pixel clock rate too high for pixel depth The video format’s pixel depth combined with the total (active + blanked) number of pixel clock cycles per horizontal scan line and horizontal scan rate exceeds the maximum internal video data bit rate supported by the generator hardware configuration. The pixel depth and/or total number of pixels per line need to be reduced in order to keep the current horizontal scan rate. 2073 Pixel rate justification too high The target pixel clock rate selected for justification of the video format exceeds the generator hardware configuration. 2074 Pixel depth not supported The video format’s pixel depth is not supported by the generator hardware configuration. 802BT/802R Video Test Generator User Guide 711 2075 Analog composite sync type not supported The video format’s analog video composite sync type selection is not supported by the generator hardware configuration. 2076 Digital sync composite type not supported The video format’s digital composite sync type selection is not supported by the generator hardware configuration. 2077 Number of digital links not allowed The number of serial digital video data links in the video format exceeds the number of links supported by the current firmware. 2078 Digital sync separate type not allowed for HDTV formats The generator hardware configuration does not support digital separate sync for the specific video type selection in the video format 2079 Number of links not supported The number of serial digital video data links in the video format exceeds the number of links supported by the generator hardware configuration. 2080 Pixel rate too low The video format’s total (active + blanked) number of pixel clock cycles per horizontal scan line multiplied by the horizontal scan rate is less than the minimum pixel clock frequency supported by the generator hardware configuration for the format video type. 2082 Number of bits not allowed The generator hardware configuration does not support the number of data bits per color for the serial digital video type selected in the video format. 2083 Invalid quantizing mode An invalid value has been specified for the DVQM parameter. 2084 Invalid Pixel Repetition In digital mode, double clocking is not supported for this specific hardware. This error may be the result of an older FPGA or hardware. 2085 Invalid Sampling Mode The value specified for DVSM is not valid and is inconsistent with the setting of DVST. 2090 Horizontal total not even The generator hardware configuration does not support interlaced video formats with a total (active + blanked) number of pixel clock cycles per horizontal scan line that is not evenly divisible by 2. 712 Appendix C Error Messages -ORThe generator hardware configuration does not support a video format with a total (active + blanked) number of pixel clock cycles per horizontal scan line that is not evenly divisible by 2 for the selected analog or digital composite sync type. 2091 Horizontal total not a multiple of 4 The generator hardware configuration does not support a video format with a total (active + blanked) number of pixel clock cycles per horizontal scan line that is not evenly divisible by 4. Mostly applies to video formats using serial digital video. 2092 Horizontal resolution not even Number of active pixels per line must be evenly divisible by 2 for the given video format type and generator hardware configuration. 2093 Horizontal sync pulse width not even Number of pixel clock cycles in the horizontal sync pulse width must be evenly divisible by 2 for the given video format type and generator hardware configuration. 2094 Horizontal sync pulse delay not even The number of pixel clock cycles in the horizontal sync pulse delay must be evenly divisible by 2 for the given video format type and generator hardware configuration. 2096 Horizontal resolution not a multiple of 4 The generator hardware configuration does not support a video format with a number of active pixels per horizontal scan line that is not evenly divisible by 4. Mostly applies to video formats using serial digital video. 2097 Horizontal sync pulse width not a multiple of 4 The generator hardware configuration does not support a video format with the number of pixel clock cycles in the horizontal sync pulse width not evenly divisible by 4. Mostly applies to video formats using serial digital video. 2098 Horizontal sync pulse delay not a multiple of 4 The generator hardware configuration does not support a video format with the number of pixel clock cycles in the horizontal sync pulse delay not evenly divisible by 4. Mostly applies to video formats using serial digital video. 2099 JRAT greater than 200MHz not allowed The 802BT generator does not support a setting of JRAT greater than 200MHz. 802BT/802R Video Test Generator User Guide 713 2130 Horizontal active too small The number of active pixels per horizontal scan line is less than the minimum supported by the generator hardware configuration. 2140 Horizontal blanking too small The video format’s horizontal blanking period expressed in microseconds and/or number of pixel clock cycles is not supported by the generator hardware configuration. 2141 Horizontal blanking too small Same as Error number 2140. Found in some firmware releases for different generator hardware configurations. 2150 Horizontal blanking too small Same as Error number 2140. Found in some firmware releases for different generator hardware configurations. 2151 Horizontal total less than horizontal resolution The video format’s total (active + blanked) number of pixel clock cycles per horizontal scan line can not be less than the number of active pixels per scan line. 2152 Horizontal resolution too large or Horizontal blanking too small Same as Error number 2140. Found in some firmware releases for different generator hardware configurations. 2155 Horizontal blanking too small Same as Error number 2140. Found in some firmware releases for different generator hardware configurations. 2180 Horizontal pulse width too small The generator hardware configuration does not support video formats having horizontal sync pulse widths less than one pixel clock cycle long. 2181 Horizontal sync pulse width not even Number of pixel clock cycles in the horizontal sync pulse width must be evenly divisible by 2 at the current pixel clock rate for the video format and generator hardware configuration. 2190 HSPW too small for HDTV sync The generator hardware configuration does not support video formats having horizontal sync pulse widths less than two pixel clock cycles long for the current video and HDTV sync type selections. 714 Appendix C Error Messages 2191 HSPW must be even for HDTV sync The number of pixel clock cycles in the horizontal sync pulse width must be evenly divisible by 2 for the current video and HDTV sync type selections. 2200 Horizontal pulse width too large The generator hardware configuration does not support a horizontal sync pulse width that is greater than the horizontal blanking period. 2201 Horizontal pulse delay not even. The number of pixel clock cycles in the horizontal sync pulse delay must be evenly divisible by 2 at the current pixel clock rate for the video format and generator hardware configuration. 2205 Frame sync pulse width too small The generator hardware configuration does not support a Frame Sync pulse width less than horizontal scan period. 2206 Frame sync pulse width too large The Frame Sync pulse width can not be greater than the total (active + blanked) number of horizontal scan lines in one frame of video. 2207 Probe sync pulse width too small The probe sync pulse width is less than minimum supported by the generator hardware configuration. 2208 Probe sync pulse width too large The probe sync pulse width is greater than maximum supported by the generator hardware configuration. 2230 Horizontal pulse delay extends sync beyond blanking The generator hardware configuration does not support the video format’s combination of horizontal sync pulse delay and pulse width that places any portion of the horizontal sync pulse outside of the horizontal blanking period. 2231 Vertical serration adjustment too big The video format’s HVSA setting beyond the maximum limit for the video type selected and generator hardware configuration. 2240 Vertical total too small The total (active + Blanked) number of horizontal scan lines per frame a progressive scan (non-interlaced) video format is lees than the minimum supported by the generator hardware configuration. 802BT/802R Video Test Generator User Guide 715 2250 Vertical total too small for interlaced format The total (active + blanked) number of horizontal scan lines per frame is less than the minimum number supported by the generator hardware configuration. 2270 Vertical total is even The generator hardware configuration does not support interlaced scan video formats having an even total (active + blanked) number of horizontal scan lines per frame. 2280 Vertical total too large The total (active + blanked) number of horizontal scan lines per frame exceeds the maximum limit for the generator hardware configuration. 2300 Vertical active too small The active number of horizontal scan lines per frame of a progressive scan (non-interlaced) video format is less than the minimum supported by the generator hardware configuration. 2310 Vertical blanking too small The number of blanked horizontal scan lines per frame for a progressive scan (non-interlaced) video format is less than the minimum supported by the generator hardware configuration. 2320 Vertical active too small for interlaced format The active number of horizontal scan lines per frame of an interlaced video format is less than the minimum supported by the generator hardware configuration. 2321 Vertical active not even The generator hardware configuration does not support interlaced scan video formats having an odd active number of horizontal scan lines per frame. 2330 Vertical blanking too small for interlaced format The number of blanked horizontal scan lines per frame for an -interlaced video format is less than the minimum supported by the generator hardware configuration. 2350 Vertical pulse too small The vertical sync pulse width is less than the minimum supported by the generator hardware configuration. 2370 Vertical pulse too large The vertical sync pulse width is greater than the maximum supported by the generator hardware configuration. 716 Appendix C Error Messages 2390 Vertical pulse too large for interlaced format The vertical sync pulse width combined with the number of pre and post-equalization pulses for an interlaced format is greater than the maximum supported by the generator hardware configuration. 2391 Incompatible analog composite sync & digital composite sync types The generator hardware configuration does not support the video format outputting both analog composite sync and digital composite sync type selections at the same time. 2392 Incompatible analog composite sync & digital separate sync types The generator hardware configuration does not support the video format outputting both analog composite sync and digital separate sync type selections at the same time. 2393 Analog composite sync type not compatible with analog video type The generator hardware configuration does not support the video format’s analog composite sync type being added to the current analog video type. 2394 ACS available on green only The generator hardware configuration supports adding analog composite sync to only the green analog video output 2395 Sync type selection incompatible with analog video type selection The video format’s analog video type selection requires the use of analog composite sync. 2396 Invalid analog composite sync type The current firmware does not support the format’s analog composite sync type parameter value (ASCT setting) or the generator hardware configuration does not support a video format’s analog composite sync type for non-interlaced operation. 2397 Invalid digital composite sync type The current firmware does not support the format’s digital composite sync type parameter value (DSCT setting) or the generator hardware configuration does not support a video format’s digital composite sync type for non-interlaced operation. 2398 Invalid digital separate sync type The current firmware or generator hardware configuration does not support the format’s digital separate sync type parameter value (DSST setting) 2399 Invalid sync type selection The current firmware does not support the format’s active sync type selection (SSST setting). 802BT/802R Video Test Generator User Guide 717 2400 Analog composite sync type and digital separate sync type incompatible The generator hardware configuration does not support analog composite sync and digital separate sync being active at he same time for the given analog composite sync type parameter value (ASCT setting) and digital separate sync type parameter value (DSST setting). 2401 Invalid horizontal sync pulse delay The generator hardware configuration does not support the format’s current horizontal sync pulse delay setting 2405 Frame sync pulse delay negative The video format’s frame sync pulse delay setting must be zero or a positive number. 2406 Frame sync pulse delay too large The video format’s frame sync pulse delay setting exceeds the maximum limit supported by the generator hardware configuration. 2407 Negative probe sync pulse vertical delay The video format’s probe pulse vertical delay setting must be zero or a positive number. 2408 Probe sync pulse vertical delay too large The video format’s probe pulse vertical delay setting exceeds the maximum limit supported by the generator hardware configuration. 2409 Negative probe sync pulse horizontal delay The video format’s probe pulse horizontal delay setting must be zero or a positive number. 2410 Probe sync pulse horizontal delay too large The video format’s probe pulse horizontal delay setting exceeds the maximum limit supported by the generator hardware configuration. 2425 Sync type selection not supported The current firmware does not support the video format’s active sync type selection (SSST setting) or the active sync type selection is not supported by the current analog video type selection (AVST setting). 2430 Vertical pulse delay extends sync beyond blanking The generator hardware configuration does not support non-interlaced video formats having a vertical sync pulse period greater that the vertical blanking period 2450 Vertical pulse delay extends sync beyond blanking The generator hardware configuration does not support interlaced video formats having a vertical sync pulse period greater that the individual blanking periods between the fields. 718 Appendix C Error Messages 2465 Pixel clock pulse gate = 1 and pixel depth = 8 The generator hardware configuration does not support outputting a pixel clock output when the video format’s pixel depth is eight bits-per-pixel. 2466 Pixel clock pulse gate = 1 not allowed The generator hardware configuration does not support a pixel clock output. 2490 EQ before too large The video format’s number of lines of pre-equalization for analog or digital composite sync must not exceed the number of lines of vertical sync pulse delay. 2495 EQ after too large for interlaced format The interlaced video format’s number of lines of post-equalization for analog or digital composite sync must not exceed the number of scan lines from the end of the vertical sync pulse to the start of video for either field. 2496 EQ after too large The non-interlaced video format’s number of lines of post-equalization for analog or digital composite sync must not exceed the number of scan lines from the end of the vertical sync pulse to the start of video. 2550 Not enough video memory The generator hardware configuration does not have enough video memory to support the video format’s combination of active pixels per line (HRES setting) and active lines per frame (VRES setting). 2551 Insufficient memory Not implemented at the time this document was created. 2553 No PCMCIA card found in drive When attempting to download a bitmap no PCMCIA card was detected in the generator’s PCM slot. 2554 PCMCIA card is write-protected When attempting to download a bitmap to a PCMCIA card, the PCM card was write-protected. 2555 PCMCIA card is bad When attempting to download a bitmap to a PCMCIA card, the PCM card was found to be bad. 802BT/802R Video Test Generator User Guide 719 2704 Invalid horizontal physical size The video format’s horizontal physical size value can not be negative. 2705 Invalid physical size units The current firmware does not support the type number used for the video format’s units of measure for physical size (USIZ setting). 2706 Invalid vertical physical size The video format’s vertical physical size value can not be negative. 2714 Pedestal swing out of range The video format’s blanking pedestal level (AVPS setting) can not be less that 0.0% of the peak video level or more than 100.0% of the peak video level. 2715 Gamma correction out of range The current firmware does not support a video format’s gamma correction factor (GAMA setting) of less than 0.1 or greater than 10. 2716 Analog video swing out of range The generator hardware configuration does not support the video format’s analog video swing value (AVSS setting) for the given analog video type selection. 2717 Sync swing out of range The generator hardware configuration does not support the video format’s analog video composite sync swing value (ASSS setting) for the given analog video type selection. 2719 Video swing calibration out of range The generator hardware configuration does not support the current user defined analog video swing calibration factors (AVSC settings) for one or more of the red, green or blue channels. The valid factory default setting is 1.00 for all three channels. 2720 Sync swing calibration out of range The generator hardware configuration does not support the current user defined analog video composite sync swing calibration factors (ASSC settings) for one or more of the red, green or blue channels. The valid factory default setting is 1.00 for all three channels. 2721 NTSC TV signals require blanking pedestal The generator hardware configuration does not support producing NTSC TV video outputs that do not use a blanking pedestal (AVPG setting of 0) as required by the NTSC specifications. 720 Appendix C Error Messages 2722 Blanking pedestal out of range for NTSC TV signal The generator hardware configuration does not support producing NTSC TV video outputs that do not use a nominal blanking pedestal level (AVPS setting) of 7.5 IRE as required by the NTSC specifications. 2741 Digital video signal type not supported The generator hardware configuration does not support any type of digital video outputs. 2742 Invalid digital video signal type The current firmware does not support the format’s digital video type selection (DVST setting). 2743 Digital video polarity not positive The generator hardware configuration and/or the firmware does not support digital video formats having a logic low level for the active (lit) pixels. 2745 Can not have analog AND digital video The generator hardware configuration does not support the simultaneous generation of analog and digital video signals. 2747 Invalid analog video signal type The current firmware for a given model generator does not support the video format’s analog video type selection. 2748 Analog video signal type not supported The generator hardware configuration does not support the video format’s analog video type selection. 2760 Digital video not supported The generator hardware configuration does not support the video format’s digital video type selection. 2761 Digital video signal swing out of range The value specified for the digital video signal swing is out of range. 2762 Digital video swing calibration out of range The value specified for the digital video swing calibration is out of range. 2800 Pseudo-random noise seed value exceeds limit The seed value for the pseudo-random noise analysis exceeds its maximum value. 802BT/802R Video Test Generator User Guide 721 2801 Pseudo-random noise sequence exceeds limit The length of the pseudo-random noise sequence exeeds maximum value. 2802 Pseudo-random noise type is not supported The pseudo-random noise type is not supported. 2803 No signal input to analyzer There is no signal input to the receive interface of the analyzer. 2804 X coordinate for delta patch out-of-range The value specified for the X coordinate of the delta patch test is out-of-range. 2805 Y coordinate for delta patch out-of-range The value specified for the Y coordinate of the delta patch test is out-of-range. 2806 Patch height must be greater than one The patch height specified for a delta error test must be greater than one. 3000-3999 Image errors 3000 Invalid color name The current firmware does not support a named color used by one or more primitives in the user defined custom image 3001 Invalid pattern name The current firmware does not support a named fill patterns used by one or more primitives in the user defined custom image 3002 No image memory There is not enough unused edit buffer memory space available to start a new custom image editing session. 3004 Invalid font name The current firmware does not support a named font used by one or more primitives in the user defined custom image 3005 Image editor running The current firmware does not allow a new custom image editing session to be started while the current custom image editing session is still running. 722 Appendix C Error Messages 3006 Nothing to save An attempt was made to save the contents of a custom image editing buffer when there was no open custom image editing session to save. 3007 Overwrite ROM Image A user defined test image can not be saved using the same name as that of a built-in test image (case insensitive). 3008 Image save failed Saving the contents of the custom image editing buffer failed for a reason other than those reported by error codes 3005 or 3006. 3010 R, G or B 8-Bit video DAC setting out of range A combination of system calibration factors, user calibration multiplier settings and video output level settings have resulted in one or more calculated input values to go below zero or above the analog video Digital-to-Analog Converter’s maximum limit of 255. 3011 R, G or B 6-Bit video DAC setting out of range A combination of system calibration factors, user calibration multiplier settings and video output level settings have resulted in one or more calculated input values to go below zero or above the analog video Digital-to-Analog Converter’s maximum limit of 63. 3015 R, G or B 10-Bit video DAC setting out of range A combination of system calibration factors, user calibration multiplier settings and video output level settings have resulted in one or more calculated input values to go below zero or above the analog video Digital-to-Analog Converter’s maximum limit of 1023. 3020 Kill EPROM image Built in test images can not be removed from the firmware. 3025 Image not found A test image of a given name could not be found as either a built-in test image in the firmware or as a user defined custom image. 3050 Grayscale video DAC setting out of range One or more internal calculations have resulted in an analog video DAC input grayscale setting below zero or greater than 100% video level. 802BT/802R Video Test Generator User Guide 723 4000-4999 Test sequence errors 4000 Invalid format name The test sequence contains one or more steps that have an invalid format name parameter. 4001 Invalid image name The test sequence contains one or more steps that have an invalid image name parameter. 4002 No sequence memory There is not enough unused edit buffer memory space available to start a new test sequence editing session. 4003 Sequence memory full There is not enough free battery backed user storage memory to save the sequence that is in the edit buffer. 4004 Sequence not found A test sequence of the given name could not be found in the user storage memory area. 4005 Sequence editor running The current firmware does not allow a new test sequence editing session to be started while the current test sequence editing session is still running. 4006 No sequence to save An attempt was made to save the contents of a test sequence editing buffer when there was no open test sequence editing session to save. 4007 Sequence buffer full No more steps can be added to the current sequence being edited because no more edit buffer space is available. 4008 Invalid delay setting in sequence The test sequence contains one or more steps that have a negative number for the step delay time. 4010 Font index out of range An attempt was made to use a font at an index location that is less than zero (0) or greater than the highest index number in use. 724 Appendix C Error Messages 4020 No font present at given index Attempt to access a font at a valid index but the specified index is empty because of a previous delete. 4030 Invalid font location Can not install a font that has not first been transferred to memory. 4040 Sequence is running A sequence editing session can not be started while a sequence is running. 4045 No sequence buffer An attempt was made to change a parameter in a sequence step when there were no sequence steps in the current sequence being edited. 4100 Pattern index out of range The selected index number for a drawing primitive’s fill pattern is less than zero or greater than the highest number used by the current firmware. 4576 Can not convert to inches, not valid units The format’s current physical units of measure (inches or millimeters) is unknown and the firmware is unable to convert a dimension to inches. 4579 Can not convert to mm, not valid units The format’s current physical units of measure (inches or millimeters) is unknown and the firmware is unable to convert a dimension to millimeters. 5000-5999 Directory errors 5002 No directory memory The DIRN or NAMI command failed because there is an insufficient amount of managed memory for the buffer request. 5003 Directory memory full The DIRA or DIRS command failed because there is insufficient room in the directory memory pool for the requested save. 5006 No directory to save An attempt was made to save the contents of a directory editing buffer when there was no open directory editing session to save. 802BT/802R Video Test Generator User Guide 725 5009 Directory list full This occurs during DIRA and DIRS commands when attempting to save more directories than supported by the current firmware. 5010 Invalid name index The value of the parameter used for a NAMQ? query is can not be zero(0). 6000-6999 Bitmap errors 6006 No map to save An attempt was made to save the contents of a bit map editing buffer when there was no open bit map editing session to save. 6020 Map not found An attempt was made to access a bit map whose name can not be found in the generator’s list of currently stored bitmaps 6030 Invalid map dimensions A bit map can not have a horizontal or vertical dimension of less than one (1) pixel. 6035 Invalid map depth The current firmware and/or generator hardware configuration does not support pixel depth setting of the selected bit map. 6036 Map data index An attempt was made to recall a bit map at an index location that is less than zero (0) or greater than the highest index number in use for bit maps. 7000-7999 LUT errors 7006 No LUT to save An attempt was made to save the contents of a color lookup table editing buffer when there was no open color lookup table editing session to save. 7010 No LUT buffer An attempt was made to modify the contents of a color lookup table editing buffer when there was no open color lookup table buffer available. 726 Appendix C Error Messages 7011 Invalid LUT Index An attempt was made to recall a color lookup table at an index location that is less than zero (0) or greater than the highest index number in use for color lookup tables. 7020 LUT not found 8000-8999 Font errors 8450 Cannot remove font. Font not found. Attempt to use FNTK command to delete a nonexistent font by name. 8455 Cannot remove built-in font Attempt to use FNTK command to delete a built-in font. 8460 Font already exists in memory Attempt made to transmit a font to the generator which already contained a font with the same name. 9000-9999 System errors 9450 Corrupted format Checksum error in data for a particular video format 9451 Bad location for format, failed verify This occurs during FMTV command and FMTV? query when you attempt to verify data integrity at an invalid location. 9452 Bad location for format verify This occurs during a FMTZ? query when you try to determine if an invalid location has been erased. 9453 Kill EPROM format Can not delete factory default formats stored in EPROM 9453 Can not change EPROM contents This occurs during FMTW or FMTZ commands when you try to overwrite or zero out an EPROM format. 802BT/802R Video Test Generator User Guide 727 9454 Bad location for format erase This occurs during FMTE command when you try to access an invalid format memory location. 9456 Bad location for format read/write This occurs during FMTR or FMTW commands when you try to read or write to an invalid format memory location. 9457 Bad location for format name read This occurs during FMTR? query when you try to read or write to an invalid format memory location. 9458 Bad location for format copy This occurs during FMTD command when you try during copying to access an invalid format memory location. 9459 Can not change EPROM contents This occurs during FMTD command when you try during copying to overwrite an EPROM format. 9460 Bad location for format duplicate This occurs during FMTD and FMTI commands when you try to use one or more invalid format memory locations as the command arguments. 9467 Bad location for format erase This occurs during FMTZ command when you try to make one or more invalid format memory locations as the command arguments. 9470 Can not change EPROM contents An attempt was made to insert a format using the FMTI command into an EPROM format memory location. 9471 Bad location for format yank This occurs when you try to remove (yank) one or more formats from invalid format memory locations using the FMTY command. 9472 Can not change EPROM contents This occurs when you try to remove (yank) one or more formats from EPROM format memory locations using the FMTY command. 9475 Can not change EPROM contents One or more EPROM format locations was given as the destination location for the FMTD command. 728 Appendix C Error Messages 9477 Error duplicating formats The memory location parameter used with the FMTD command is greater than the memory location parameter. 9480 Format not found / Format data missing The FMTR command tried to read a format from an empty format storage location. 9490 DDC mod not present The generator hardware configuration does not support DDC communications. 9491 DDC not available The generator hardware configuration does not support DDC communications. 9492 DDC2B no ACK from receiver Low level DDC communications failed with Unit Under Test (UUT). No DDC acknowledgment bit was received from the UUT. 9493 DDC2B arbitration lost Low level DDC communications failed with Unit Under Test (UUT). DDC bus arbitration lost with the UUT. 9494 DDC2B timeout on bus Low level DDC communications failed with Unit Under Test (UUT). DDC communications timed out with the UUT. 9496 EDID header not found A valid block of header data could not be found in the EDID data read back from Unit Under Test (UUT). 9497 DDC old monitor A DDC compliant Unit Under Test (UUT) could not be found connected to the generator. 9498 I2C address missing There was a communications error within the generator hardware architecture because the device address was missing. 9499 I2C count missing There was a communications error within the generator hardware architecture because the data count was missing. 802BT/802R Video Test Generator User Guide 729 9500 I2C stream too big There was a communications error within the generator hardware architecture because the data stream size exceeded the size supported by the device. 9500 Sequence data not found An attempt was made to use the SEQR command to read a sequence from an empty sequence storage location. 9501 I2C data missing There was a communications error within the generator hardware architecture because the device data stream was missing. 9502 I2C register missing There was a communications error within the generator hardware architecture. 9503 I2C data byte missing There was a communications error within the generator hardware architecture because the device data stream had missing data. 9504 Serial digital video PLL not locked There is an internal problem with the generator’s serial digital video hardware’s Phase Lock Loop circuit. 9505 TV output hardware not ready The generator’s serial digital video generating hardware is not yet ready to output video 9506 Serial digital video hardware not ready The generator’s TV signal generating hardware reports it is not yet ready to output valid video 9507 I2C offset missing There was a communications error within the generator hardware architecture 9508 Invalid HDCP receiver KSV The HDCP Key Selection Vector returned from the HDCP receiver in the Unit Under Test (UUT) is not valid. 9520 HDCP key combination not supported The HDCP key combination between the Tx and the Rx is invalid. The Tx may have production keys and the Rx public keys. 9521 HDCP failed after a while The HDCP authentication started but failed after a while. 730 Appendix C Error Messages 9522 HDCP key combination not supported The HDCP authentication did not start. 9523 HDCP production keys not supported HDCP test initiated and specified production keys where are not supported in generator option. 9524 Invalid transmitter KSV HDCP video transmitter KSV sent by the generator is invalid. 9525 HDCP Ri value not ready HDCP authentication cannot start because HDCP Ri value (link verification response) at the transmitter is not ready. 9527 HDCP Ri do not match HDCP authentication cannot start because HDCP Ri (link verification response) values at the transmitter and receiver do not match. 9528 HDCP was interrupted HDCP authentication was interrupted possibly by disconnecting the cable. 9529 HDCP receiver not detected HDCP authentication failed to start because the hot plug was not detected. 9530 HDCP invalid for animation HDCP test will not run when an animated image is loaded. 9531 I2C segment number missing The segment number of the enhanced DDC bus is missing. 9532 I2C address 1 missing The first address of the enhanced DDC bus is missing. 9533 I2C address 2 missing The second address of the enhanced DDC bus is missing. 9600 Can not save format to EPROM An attempt was made to save a format edit buffer’s contents to a location in the firmware EPROM. 802BT/802R Video Test Generator User Guide 731 10000-10999 System errors 10000 Out of memory There is not enough unused battery backed user memory space to store the contents of the given edit buffer 10010 Invalid file check sum The data object file that has been recalled from the generator’s memory contains an invalid checksum. Data may be corrupted. 10020 Invalid file version The data object file that has been recalled from memory contains a file version number that does not match the current firmware. Data may not be properly interpreted by the firmware 10025 File type The data object file that has been recalled from memory contains a file type identification that is not supported by the current firmware. 10026 File size The size of the data object file that has been recalled from memory does not match the size information stored in the file’s header data. 10030 Feature not implemented The generator hardware configuration does not support one or more settings in the video format 10035 Video board not detected An attempt was made to reprogram the firmware Flash EPROMs in a Model 822 series generator without a video board installed. The video board’s memory is used as a buffer for the initial uploading of the firmware data. 10100 Filename alias not found An attempt was made to delete a filename alias that does not exist. 10200 Font not overwriteable An attempt was made to save the contents of a font editing buffer to a location in the firmware EPROM. 10205 Font save failed There is not enough unused battery backed user memory space to store the contents of the font editing buffer. 732 Appendix C Error Messages 10210 Font table range The recalled font data object contains a reference to a nonexistent table in the data object. 10215 Font table Index range The recalled font data object contains a reference to a nonexistent location in one of the tables in the data object. 10220 Font not found An attempt was made to recall a font by name that is not stored in the generator. 10225 Can not delete font in EPROM Ann attempt was made to delete a font stored in the firmware EPROM. 10230 Invalid font check mode The current firmware does not support the selected test method on the contents of the font edit buffer. 10235 No font definition The recalled font does not contain valid font definition data need to determine the size needed by the edit buffer. 10240 Font character high range The character height setting of the font in the edit buffer is less than one or greater than the maximum supported by the current firmware. 10241 Font ascent descent sum The character height setting of the font in the edit buffer is does not match the sum of the character ascent and descent settings 10242 Invalid font character range The first or last character number setting of the font in the edit buffer is greater than the maximum supported by the current firmware or the number of the first character is greater than the number of the first character. 802BT/802R Video Test Generator User Guide 733 734 Appendix C Error Messages
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : Yes Page Count : 744 Page Mode : UseOutlines XMP Toolkit : XMP toolkit 2.9.1-13, framework 1.6 About : uuid:820079c9-6e98-41dc-864c-b370c9fc9b6d Producer : Acrobat Distiller 6.0 (Windows) Create Date : 2004:12:22 11:47:27Z Creator Tool : FrameMaker 7.1 Modify Date : 2004:12:22 13:35:22-06:00 Metadata Date : 2004:12:22 13:35:22-06:00 Document ID : uuid:07e937cd-6062-4684-a04e-b1739f0ddf30 Format : application/pdf Title : ug.book Creator : nkendall Author : nkendallEXIF Metadata provided by EXIF.tools