Quantum Instruments COP A Wireless Radio Commander Unit for Digital Cameras to Control Remote Flashes User Manual User s Manual
Quantum Instruments Inc A Wireless Radio Commander Unit for Digital Cameras to Control Remote Flashes User s Manual
User's Manual
MAN – TTL Mode switch for Remote R1, R2, R3 Ratio / Manual Power setting control for Remote R1, R2, R3 ACCY connector for Qflash T5d-R ON / OFF switch AF – Auto Focus light is ON ON AF TTL R1 OFF TTL R2 TTL R3 / LOCAL CHAN Qflash® Co-Pilot QF91 Channel select switch 0 - 7 USB connector Shoe Mount Wireless Radio Commander for Qflash 5d-R and TRIO Operating Instructions To separately set exposures of remote flashes, set them, to different Remote Groups. Any number of remotes may be combined in a Remote Group, for the same mode / exposure. Quantum Trio and / or Qflash T5d-R with an FW8R or FW7Q receiver and / or Any non Quantum flash that can be triggered by a sync signal, with an FW8R or FW7Q. A Remote Group can consist of : The Co-Pilot can control the exposure of three Remote Groups (R1, R2, and R3) or two Remote Groups (R1, R2) and a local Qflash T5d-R. 1 Introduction ISO TTL TTL R2 TTL R3 / LOCAL Note : When using a non Quantum flash as a Remote Group set the MODE switch to M. MODE switch – this control sets the mode of the Remote Group to M (manual) or TTL. If the Remote Group is a Quantum Trio or Qflash T5d-R R1 RATIO / MANUAL POWER SETTINGS – this control adjusts the exposure of the Remote Group. Ratio settings can be set from -27 to +2. Manual power settings can be set from 1/16- to 1/1. This control also has an OFF position. When set in the OFF position the flash in the Remote Group will not fire. R1, R2, and R3 (when no Qflash T5d-R is connected to the ACCY connector) Each Remote Group has two controls. TTL TTL R2 TTL R3 / LOCAL MODE switch – this control is disabled when a Qflash T5d-R is connected to the Co-Pilot. The MODE button on the local Qflash T5d-R overrides the mode setting. R1 RATIO / MANUAL POWER SETTINGS – this control adjusts the ratio of the local Qflash T5d-R, when the Qflash is in QTTL mode. Ratio settings can be set from -27 to +2. 3 .1 No Local Qflash T5d-R connected 3 .2 Local Qflash T5d-R connected Remotes will operate in Groups R1, R2 only. SET NOTE: When using a non Quantum flash the Co-Pilot will provide a sync signal to fire the flash, but will not control the exposure. The MAN-TTL mode switch for this Group must be set to M. Use the ZONE switches to select the remote group. Zone 1 ON = Remote Group R1, Zone 2 ON = Remote Group R2, Zone 3 ON = Remote Group R3. A Remote Group can consist of a Quantum Trio, Qflash T5d-R with an FW8R or FW7Q receiver, or any non Quantum flash that can be triggered by a sync signal. The Co-Pilot will fire a non Quantum flash but not control it’s exposure. MODE RADIO 200 When a Qflash T5d-R is connected to the Co-Pilot ACCY connector, Group R3 becomes the Local ratio control Co-Pilot setup SAVE FIRE OPT F 5.6 7 3.6 –32 FT AUTO Connect a flash unit to a FW8 or FW10w receiver. Set the channel on the receiver, to the same channel set on Co-Pilot. The Co-Pilot can control the exposure of three Remote Groups (R1, R2, and R3) or two Remote Groups (R1, R2) and a local Qflash T5d-R. REMOTE GROUP R1 NOTE: Set all zones to ON. NOTE: There is no need to set the ZONES when using Wireless Remote Groups with the Trio. 2.3 Using a Non Quantum flash as a remote Set the channel on the FW8R or FW7Q. There are eight channels available, 0 through 7. The Qflash T5d-R may display a message that it needs a signal from the Local flash to activate this mode. The message will disappear when you set up the Co-Pilot WIRELESS GROUP R1 TO ACTIVATE CONTROL FROM LOCAL QFLASH TURN LOCAL QFLASH OFF THEN ON Press the mode button, on the Qflash t5d-R, then use the up or down buttons to select Wireless Remote Group 1 or Wireless Remote Group 2. 2.2 Using a Qflash T5d-R with an FW8R or FW7Q receiver as a remote Press the RADIO softkey to set the channel. There are eight channels available, 0 through 7. Press the mode button, on the Trio, use the left or right arrow buttons to select Wireless Remote Group. Press one of the soft keys to choose R1, R2, or R3. 2.1 Using a Quantum Trio as a remote Note: All channels must be set to the same channel number. A remote Group can consist of Quantum Trio set to Remote Group R1, R2, R3 Qflash T5d-R set to Wireless Group R1, R2. When used with an FW8R or FW7Q receiver. Any non Quantum flash that can be triggered by an external sync signal from an FW8R or FW10w. 2 Setting up the Remote Groups IMPORTANT – CAUTION Changes or modifications to this equipment could void your authority to use this product under the equipment authorization granted by the regulating agencies Pxxxx -Reorient or relocate the receiving antenna. -Increase the separation between the equipment and receiver. -Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -Consult the dealer or an experienced radio/TV technician for help. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of thefollowing measures: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. Les changements ou modififications a cet appareil sans expressement approuvee par la partie responsable de conformite pourraient annuler I'autorite de I'utilisateur de faire fonctionner cet equipement. • Reorienter ou deplacer I'antenne de reception. • Augmenter la distance entre I'equipement et Ie recepteur. • Branchez I'appareil dans une prise sur un circuit different de celui auquel Ie recepteur est connecte. • Consultez votre revendeur ou un technicien radio / TV pour assistance.Avertissement Rien ne garantit cependant que I'interference ne se produira pas dans une installation particuliere. Si cet equipement provoque des interferences nuisibles a la reception radio ou de television, qui peut etre determine en comparant et en I'eteignant, I'utilisateur est encourage a essayer de corriger les interference par une ou plusieurs des mesures suivantes: Cet equipement genere, utilise et peut emettre des frequences radio et, s'il n'est pas installe et utilize conformement ment aux instructions du fabricant, peut causer des interferences nuisibles aux communications radio. Conformite aux normes FCC Cet equipement a ete teste et trouve conforme aux limites pour un dispositif numerique de classe B, conformement a la Partie 15 des reglements de la FCC. Ces limites sont con cues pour fournir une protection raisonnable contre les interferences nuisibles dans une installation residentielle. Industry Canada Statement This Class B digital apparatus complies with Canadian ICES-003. Cet appareil numerique de la classe B est conforme a la norme NMB-003 du Canada. This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. Cet appareil est conforme avec Industrie Canada exempt de licence Rss standard(s). Son fonctionnement est soumis aux deux conditions suivantes : (1) cet appareil ne peut causer d'interferences, et (2) cet appareil doit accepter toute interference, y compris des interferences qui peuvent provoquer un fonctionnement indesirable du peripherique. The installer of this radio equipment must ensure that the antenna is located or pointed such that it does not emit RF field in excess of Health Canada limits for the general population: consult Safety Code 6, obtainable from Health Canada’s website www.hc-sc.gc.ca/rpb. Quantum Instruments Inc. 10 Commerce Drive, Hauppauge NY 11788-3968 USA Tel: 1-631-656-7400 Fax: 1-631-656-7410 www.qtm.com
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : Yes Language : en-US Tagged PDF : Yes XMP Toolkit : Adobe XMP Core 4.2.1-c041 52.342996, 2008/05/07-20:48:00 Producer : Microsoft® Office Word 2007 Format : application/pdf Creator : orcus Creator Tool : Microsoft® Office Word 2007 Create Date : 2012:04:02 13:29:27Z Modify Date : 2012:04:05 14:41:11-07:00 Metadata Date : 2012:04:05 14:41:11-07:00 Document ID : 7BA4DAA5-CCAF-48BF-BC43-9A729935F786 Instance ID : uuid:b48f8e5f-3cd0-4f4e-b3c5-df9681785208 Part : 1 Conformance : B Page Count : 3 Author : orcusEXIF Metadata provided by EXIF.tools