Quantum Scalar 50 Users Guide User’s

Tape Library PX502 81-81768-02_A01

2015-07-28

: Quantum Quantum-Scalar-50-Users-Guide-780315 quantum-scalar-50-users-guide-780315 quantum pdf

Open the PDF directly: View PDF PDF.
Page Count: 290

DownloadQuantum Quantum-Scalar-50-Users-Guide- Scalar 50 User’s Guide  Quantum-scalar-50-users-guide
Open PDF In BrowserView PDF
User’s Guide User’s Guide User’s Guide User’s Guide User’s Guide

Quantum Scalar 50

Scalar Series
81-81768-02 A01

Quantum Scalar 50 User’s Guide, 81-81768-02 A01, July 2008, Made in USA.
Quantum Corporation provides this publication “as is” without warranty of any kind, either express or
implied, including but not limited to the implied warranties of merchantability or fitness for a particular
purpose. Quantum Corporation may revise this publication from time to time without notice.
COPYRIGHT STATEMENT
Copyright 2008 by Quantum Corporation. All rights reserved.
Your right to copy this manual is limited by copyright law. Making copies or adaptations without prior
written authorization of Quantum Corporation is prohibited by law and constitutes a punishable violation of
the law.
TRADEMARK STATEMENT
DLT, SDLT, DLTtape III, DLTtape IV and Super DLTtape I are all trademarks of Quantum Corporation.
Other trademarks may be mentioned herein which belong to other companies.

Contents

Preface

xvii
StorageCare Guardian................................................................................... xxii

Chapter 1

Library Description

1

Overview............................................................................................................. 2
Tape Drives......................................................................................................... 5
Tape Drive Types........................................................................................ 5
Library Features ................................................................................................. 8
Front Panel................................................................................................... 8
Internal Layout.......................................................................................... 10
Back Panel.................................................................................................. 11
DLTSage™ Tape Security............................................................................... 13
Mixed Media Support ..................................................................................... 13
Capacity on Demand....................................................................................... 13
Enabling Capacity on Demand............................................................... 14
Library Scalability (Stacked Configurations)............................................... 15
Multiple Library Stack Requirements ................................................... 15
Getting Started ................................................................................................. 18
Installing the Quantum Scalar 50 ........................................................... 18
Cabling the Quantum Scalar 50 Series .................................................. 19
Loading Tape Cartridges......................................................................... 20
Initial Configuration................................................................................. 20
Quantum Scalar 50 User’s Guide

iii

Contents

Chapter 2

Basic Library Operations

21

Installing Tape Cartridges .............................................................................. 21
Taking ESD Precautions .......................................................................... 23
SDLT Cartridges ....................................................................................... 24
LTO Cartridges ......................................................................................... 26
Cleaning Cartridges.................................................................................. 28
Preparing the Library for Operation ............................................................. 30
Close the Cabinet Doors and Access Panels ......................................... 30
Connecting to Host Workstations .......................................................... 31
Turning the Library On and Off .................................................................... 36
Turning On the Library............................................................................ 36
Turning Off the Library ........................................................................... 37
Placing the Library On-line or Off-line.................................................. 37
Using the OCP .................................................................................................. 37
Home Screen.............................................................................................. 37
OCP Buttons .............................................................................................. 38
OCP Components ............................................................................................ 38
Info Screen ................................................................................................. 40
Operations Screen ..................................................................................... 45
Setup Screen............................................................................................... 50
Diags Screen .............................................................................................. 57
Load Port Configuration................................................................................. 60

Chapter 3

Quantum Scalar 50 Remote Management

63

Quantum Scalar 50 Web Pages ...................................................................... 64
Quantum Scalar Web Page Menu Items................................................ 64
Accessing Scalar 50 Web Pages............................................................... 67
Using the Quantum Scalar 50 Web Pages ............................................. 67
Quick Status............................................................................................... 68
Status.................................................................................................................. 70
Overview Page .......................................................................................... 70
Hardware Status Page.............................................................................. 71
Event Log Page.......................................................................................... 72
Statistics Page ............................................................................................ 73
Operations......................................................................................................... 77
Accessing the Operations Page............................................................... 77
Find Page.................................................................................................... 78
Move Page.................................................................................................. 80
Inventory Page .......................................................................................... 82
Drives Page ................................................................................................ 83
Quantum Scalar 50 User’s Guide

iv

Contents

Setup .................................................................................................................. 84
Accessing the Setup Page ........................................................................ 85
Identification.............................................................................................. 86
Users ........................................................................................................... 87
Key Users ................................................................................................... 88
SCSI/Fibre ................................................................................................. 91
iSCSI Bridge ............................................................................................... 92
Network ..................................................................................................... 93
Events ......................................................................................................... 95
Date & Time............................................................................................... 99
Library ...................................................................................................... 101
Partitions .................................................................................................. 102
Field Service............................................................................................. 108
Setup Wizard ........................................................................................... 108
Secure Key....................................................................................................... 113
Protection Mode for Cartridges ............................................................ 115
Enable/Disable Secure Key for Drives ................................................ 116
Select Secure Key for Library ................................................................ 117
Assign Secure Key to Cartridge............................................................ 117
Create Secure Key Name/Secure Key Pair......................................... 118
Delete Secure Key Name ....................................................................... 119
Backup Secure Key File.......................................................................... 120
Upload Secure Key File.......................................................................... 121
Secure Key Best Practices and Tape Migration ......................................... 122
Best Practices ........................................................................................... 122
Key Migration Scenarios........................................................................ 122
Utilities ............................................................................................................ 124
Library ...................................................................................................... 125
System Tests ............................................................................................ 127
Maintenance ............................................................................................ 129
Logs........................................................................................................... 131
Tasks ......................................................................................................... 133
Reference ......................................................................................................... 134
Logout.............................................................................................................. 136

Chapter 4

SNMP Trap List

137

Chapter 5

Troubleshooting

164

Common Problems and Solutions............................................................... 164
Quantum Scalar 50 User’s Guide

v

Contents

Start-up Problems ................................................................................... 165
OCP Problems ......................................................................................... 166
Robotics (Hand) Problems..................................................................... 166
Operating Problems ............................................................................... 168
Interpreting System LED Status .................................................................. 170
Operator Control Panel (OCP) LED Status......................................... 171
System Controller Board (SCB) LED Status........................................ 171
Power Supply LED Status ..................................................................... 175
Tape Drive LED Status........................................................................... 176

Appendix A

Specifications

177

Physical Specifications .................................................................................. 178
Performance Specifications........................................................................... 179
Reliability Specifications ............................................................................... 180
Tape Drive Specifications ............................................................................. 180
Environmental Specifications....................................................................... 181
Noise Levels............................................................................................. 181
SCSI Specifications......................................................................................... 181

Appendix B

SDLTtape Cartridge Maintenance

182

Handling DLTtape Cartridges ..................................................................... 182
Visual Inspection of DLTtape Cartridges................................................... 183
When To Visually Inspect a DLTtape Cartridge ................................ 183
Visual Inspection Procedure ................................................................. 183

Appendix C

Installing the Scalar 50 Library

187

Selecting an Installation Location................................................................ 187
Rack Space Requirements...................................................................... 188
Environmental Conditions .................................................................... 189
Preparing for the Installation ....................................................................... 189
Providing Necessary Tools and Equipment ....................................... 189
Taking ESD Precautions ........................................................................ 189
Installing the Library ..................................................................................... 190
Locating the Mounting Position ........................................................... 190
Installing the Library.............................................................................. 192
Loading the Tape Cartridges ................................................................ 207
Quantum Scalar 50 User’s Guide

vi

Contents

Initial Configuration............................................................................... 207
Emergency Library Access ........................................................................... 213

Appendix D

Repacking the Scalar 50 Library

216

Removing the Library from the Rack.......................................................... 217
Installing the Internal Shipping Restraints ................................................ 220
Packing the Library for Shipment ............................................................... 224

Appendix E

Firmware Upgrade Instructions for Stacked Libraries

226

Changing the Library Stack Role ................................................................. 227
Uploading Library Firmware ....................................................................... 228
Returning the Library Stack Role ................................................................ 233

Appendix F

Regulatory Statements

235

Laser Statement ....................................................................................... 238

Glossary

259

Index

261

Quantum Scalar 50 User’s Guide

vii

Figures

Quantum Scalar 50 User’s Guide

Figure 1

Scalar 50 ......................................................................................... 2

Figure 2

Slot Numbering, Scalar 50 SDLT ............................................... 3

Figure 3

Slot Numbering, Scalar 50 LTO.................................................. 4

Figure 4

Scalar 50 Front Panel.................................................................... 8

Figure 5

Scalar 50 Internal Layout .......................................................... 10

Figure 6

Scalar 50 Back Panel................................................................... 12

Figure 7

Multiple Library Stack (Cross Section..................................... 16

Figure 8

Rack Space Requirements ......................................................... 19

Figure 9

Connecting the Library to the Local Area Network ............. 20

Figure 10

Inserting a Barcode Label (SDLT) ............................................ 25

Figure 11

SDLT Cartridges......................................................................... 26

Figure 12

LTO Cartridges........................................................................... 28

Figure 13

SDLT Cleaning Cartridges........................................................ 29

Figure 14

LTO Cleaning Cartridges .......................................................... 29

Figure 15

Closing the Scalar 50 Front Doors............................................ 30

Figure 16

Scalar 50 Cable Configuration (SCSI Full Height Drives).... 32

Figure 17

Scalar 50 Cable Configuration (Native Fibre Channel Full
Height Drives) ............................................................................ 32
viii

Figures

Quantum Scalar 50 User’s Guide

Figure 18

Scalar 50 Cable Configuration (SCSI Half-Height Drives)... 33

Figure 19

Scalar 50 Cable Configuration (SAS Half-Height Drives) .... 33

Figure 20

Scalar 50 Cable Configuration (Native Fibre Channel HalfHeight Drives)............................................................................. 34

Figure 21

Scalar 50 Cable Configuration (Stacked)................................. 35

Figure 22

Turning On the Library ............................................................. 36

Figure 23

OCP Home Screen...................................................................... 38

Figure 24

OCP Component Tree................................................................ 39

Figure 25

Info Screen ................................................................................... 40

Figure 26

Overview Screen......................................................................... 41

Figure 27

Hardware Screen ........................................................................ 42

Figure 28

Event Log Screen ........................................................................ 43

Figure 29

Statistics Screen........................................................................... 44

Figure 30

Operations Screen....................................................................... 45

Figure 31

Library Operations Screen ........................................................ 46

Figure 32

Match Label Screen .................................................................... 47

Figure 33

Move From Screen...................................................................... 48

Figure 34

Drive Operations Screen ........................................................... 49

Figure 35

Setup Screen ................................................................................ 51

Figure 36

Cabinet Setup Screen ................................................................. 51

Figure 37

Partitions Setup Screen .............................................................. 53

Figure 38

Security Screen............................................................................ 54

Figure 39

Network Screen .......................................................................... 55

Figure 40

Date and Time Screen ................................................................ 57

Figure 41

Diagnostic Screen ....................................................................... 57

Figure 42

System-level Test Screen ........................................................... 58

Figure 43

Subsystem Tests Screen ............................................................. 59

Figure 44

Component Tests Screen ........................................................... 60

Figure 45

Load Port Settings ...................................................................... 62

ix

Figures

Quantum Scalar 50 User’s Guide

Figure 46

Quantum Scalar 50 Web Page Menu Items ............................ 65

Figure 47

Quantum Tape Security and Tape Encryption Menus ......... 66

Figure 48

Overview Page............................................................................ 67

Figure 49

Status Page .................................................................................. 70

Figure 50

Hardware Status Page ............................................................... 71

Figure 51

Event Log Page ........................................................................... 72

Figure 52

Statistics Page.............................................................................. 76

Figure 53

Operations Page.......................................................................... 77

Figure 54

Find Page ..................................................................................... 78

Figure 55

Move Page ................................................................................... 81

Figure 56

Inventory Page............................................................................ 82

Figure 57

Drives Page.................................................................................. 83

Figure 58

Setup Page ................................................................................... 85

Figure 59

Users Page ................................................................................... 87

Figure 60

Create Key User .......................................................................... 89

Figure 61

Remove Secure User .................................................................. 89

Figure 62

Change Key User Password...................................................... 90

Figure 63

SCSI Page ..................................................................................... 91

Figure 64

iSCSI Page.................................................................................... 93

Figure 65

Network Page ............................................................................. 94

Figure 66

Events Page ................................................................................. 96

Figure 67

SNMP Section of Event Page .................................................... 99

Figure 68

Date & Time Page..................................................................... 100

Figure 69

Library Page .............................................................................. 101

Figure 70

Native Fibre Channel Partition Example .............................. 103

Figure 71

Partitions Page .......................................................................... 105

Figure 72

Setup Wizard............................................................................. 109

Figure 73

Setup Wizard (Library Offline) .............................................. 109

Figure 74

Setup Wizard (Date and Time)............................................... 110

x

Figures

Figure 75

Setup Wizard (Configure Devices) ........................................ 111

Figure 76

Setup Wizard (Configuring Load Ports)............................... 111

Figure 77

Setup Wizard (Configuring Partition)................................... 112

Figure 78

Setup Wizard (Wizard Completed) ....................................... 113

Figure 79

Secure Key Page........................................................................ 114

Figure 80

Protection Mode for Cartridges.............................................. 115

Figure 81

Enable/Disable Secure Key for Drives.................................. 116

Figure 82

Select Secure Key for Library.................................................. 117

Figure 83

Assign Secure Key to Cartridge ............................................. 117

Figure 84

Create Secure Key Name/Secure Key Pair .......................... 118

Figure 85

Delete Secure Key Name ......................................................... 119

Figure 86

Backup Secure Key File ........................................................... 120

Figure 87

Upload Secure Key File ........................................................... 121

Figure 88

Utilities Page ............................................................................. 124

Figure 89

Library Page .............................................................................. 125

Figure 90

Selftest Page............................................................................... 127

Figure 91

System Tests Page .................................................................... 128

Figure 92

Maintenance Page .................................................................... 129

Figure 93

Logs Page................................................................................... 132

Figure 94

View Log Page ......................................................................... 132

Figure 95

Tasks Page ................................................................................. 133

Figure 96

Task List Example .................................................................... 134

Figure 97

Reference Page .......................................................................... 135

Figure 98

About Page ................................................................................ 135

Figure 99

Location of the Reel Locks and the Hub ............................... 184

Figure 100 Opening the Tape Cartridge Door ......................................... 185
Figure 101 Write Protect Switch ................................................................ 186
Figure 102 Rack Space Requirements ....................................................... 188
Figure 103 Rail Adapter Orientation......................................................... 194

Quantum Scalar 50 User’s Guide

xi

Figures

Figure 104 Assembling the Left-Hand Rack Mount Shelves................. 195
Figure 105 Assembling the Right-Hand Rack Mount Shelves .............. 196
Figure 106 Installing the Rack Mount Shelves......................................... 197
Figure 107 Back Mounting Brackets.......................................................... 199
Figure 108 Installing the Scalar 50 in the Rack ........................................ 200
Figure 109 Securing the Back of the Library ............................................ 201
Figure 110 Scalar 50 Tape Drive Numbering........................................... 202
Figure 111 Scalar 50 Cable Configuration (SCSI Full Height Drives) .. 203
Figure 112 Scalar 50 Cable Configuration (Native Fibre Channel Full
Height Drives)........................................................................... 204
Figure 113 Scalar 50 Cable Configuration (SCSI Half-Height Drives). 204
Figure 114 Scalar 50 Cable Configuration (SAS Half-Height Drives) .. 205
Figure 115 Scalar 50 Cable Configuration (Native Fibre Channel HalfHeight Drives)........................................................................... 205
Figure 116 Scalar 50 Cable Configuration (Stacked)............................... 206
Figure 117 Turning On the Library ........................................................... 208
Figure 118 Setup Screen .............................................................................. 210
Figure 119 Library Options Screen............................................................ 210
Figure 120 Date and Time Screen .............................................................. 211
Figure 121 Network Screen ........................................................................ 212
Figure 122 Opening the Right and Left Magazine Access Doors ......... 214
Figure 123 Removing the Magazines ........................................................ 215
Figure 124 Removing the Scalar 50 Library ............................................. 219
Figure 125 Opening the Right and Left Magazine Access Doors ......... 221
Figure 126 Installing the Hand Restraint.................................................. 222
Figure 127 Installing the Restraining Bolt ................................................ 223
Figure 128 Preparing the Library for Shipping ....................................... 225
Figure 129 Setup Screen .............................................................................. 227
Figure 130 Cabinet Screen .......................................................................... 227
Figure 131 Connecting to the Library SCB............................................... 229

Quantum Scalar 50 User’s Guide

xii

Figures

Figure 132 Overview Page.......................................................................... 230
Figure 133 Utilities Page ............................................................................. 231
Figure 134 Maintenance Page .................................................................... 232
Figure 135 Setup Screen .............................................................................. 233
Figure 136 Cabinet Screen .......................................................................... 233

Quantum Scalar 50 User’s Guide

xiii

Tables

Quantum Scalar 50 User’s Guide

Table 1

DLT-S4 Performance Characteristics......................................... 5

Table 2

Quantum LTO-3 (Half- Height) Performance Characteristics
6

Table 3

HP LTO-3 (Full Height) Performance Characteristics ............ 6

Table 4

HP LTO-4 (Half- Height) Performance Characteristics.......... 7

Table 5

HP LTO-4 Performance Characteristics.................................... 7

Table 6

Front Panel Features .................................................................... 9

Table 7

Scalar 50 Capacity Levels .......................................................... 14

Table 8

Capacity, Scalar 50 Multiple Library Stack - LTO (42U High
Rack)17

Table 9

Capacity, Scalar 50 Multiple Library Stack - SDLT (42U High
Rack)............................................................................................. 17

Table 10

Hardware Information .............................................................. 42

Table 11

Library Operations Options...................................................... 46

Table 12

Drive Options ............................................................................. 50

Table 13

Cabinet Setup.............................................................................. 52

Table 14

Partitions Setup .......................................................................... 53

Table 15

Security Setup ............................................................................. 54

xiv

Tables

Quantum Scalar 50 User’s Guide

Table 16

Import/Export Option Settings................................................ 61

Table 17

Quick Status Library Health Conditions ................................ 68

Table 18

Quick Status Health Messages ................................................. 68

Table 19

Statistics Information ................................................................. 74

Table 20

Identification Information......................................................... 86

Table 21

User Information ........................................................................ 88

Table 22

Native Fibre Channel Configuration Options........................ 92

Table 23

Network Configuration Fields ................................................. 95

Table 24

Email Notification ...................................................................... 97

Table 25

Send Email Test .......................................................................... 97

Table 26

SNMP Trap Selections ............................................................... 99

Table 27

Library Configuration.............................................................. 101

Table 28

Capacity on Demand Configuration ..................................... 102

Table 29

Creating a Partition .................................................................. 106

Table 30

Configuration File Types......................................................... 130

Table 31

Start-up Problems..................................................................... 165

Table 32

OCP Problems........................................................................... 166

Table 33

Robotics (Hand) Problems ...................................................... 167

Table 34

Problems During Library Operation ..................................... 168

Table 35

OCP LED States ........................................................................ 171

Table 36

SCSI SCB LED ........................................................................... 172

Table 37

Surrogate SCB LED .................................................................. 173

Table 38

Fibre Channel SCB LED .......................................................... 174

Table 39

Power Supply LEDs ................................................................. 175

Table 40

Tape Drive LEDs ...................................................................... 176

Table 41

Unit Dimensions/Weight ....................................................... 178

Table 42

Capacities................................................................................... 178

Table 43

Performance Specifications ..................................................... 179

Table 44

Library Performance ................................................................ 179

xv

Tables

Quantum Scalar 50 User’s Guide

Table 45

Reliability Specifications ......................................................... 180

Table 46

Tape Drive Specifications........................................................ 180

Table 47

Power ......................................................................................... 181

Table 48

Climate ....................................................................................... 181

Table 49

Rack Hole Types ....................................................................... 190

Table 50

Scalar 50 Rail Hole Patterns and Mounting Positions ........ 191

Table 51

Library Mounting Hardware.................................................. 192

Table 52

Back Mounting Bracket Orientation ...................................... 198

Table 53

Setting Up the Cabinet............................................................. 211

xvi

Preface

Audience

This document is written for operators of the Scalar 50 tape library.

Purpose

This document explains how to use the Scalar 50 tape library.

Document Organization

This document is organized as follows:
• Chapter 1, Library Description, provides an overview of the Scalar 50
library.
• Chapter 2, Basic Library Operations, introduces the library OCP
screens and explains how to use them to perform basic library
operations such as moving tape cartridges within the library,
removing the tape cartridge magazines, and viewing library
information.
• Chapter 3, Quantum Scalar 50 Remote Management, explains how to
change the library configuration and manage the library using the
remote GUI.
• Chapter 4, SNMP Trap List, lists the SNMP traps supported by the
Scalar 50 library.
• Chapter 5, Troubleshooting, discusses problems you may encounter
during the setup and operation of the Scalar 50 library.

Quantum Scalar 50 User’s Guide

xvii

Preface

• Appendix A, Specifications, lists the specifications for the Scalar
50 library.
• Appendix B, SDLTtape Cartridge Maintenance, provides
guidelines for handling SDLT cartridges and visually
inspecting them if necessary.
• Appendix C, Installing the Scalar 50 Library, provides installation
information for the Scalar 50 library.
• Appendix D, Repacking the Scalar 50 Library, provides repacking
information for the Scalar 50 library.
• Appendix E, Firmware Upgrade Instructions for Stacked Libraries,
provides procedures for upgrading library firmware to stacked
libraries.
• Appendix F, Regulatory Statements, provides regulatory
information for the Scalar 50 library.
This document concludes with a glossary and a detailed index.

Notational Conventions

This manual uses the following conventions:
Note:

Notes emphasize important information related to the main
topic.

Caution:

Cautions indicate potential hazards to equipment and are
included to prevent damage to equipment.

Warning:

Warnings indicate potential hazards to personal safety and
are included to prevent injury.

This manual uses the following:
• Right side of the library — Refers to the right side as you face
the component being described.
• Left side of the library — Refers to the left side as you face the
component being described.

Quantum Scalar 50 User’s Guide

xviii

Preface

Related Documents

Documents related to the Scalar 50 tape library are shown below:

0

Quantum Scalar 50 Documentation

Document No.

Title

Description

81-81767

Scalar 50 Quick Start

Provides information on
installing the Scalar 50
library in a rack.

81-81769

Scalar 50 Tape Drive
Installation Instructions

Provides information on
installing tape drives in
the Scalar 50 library.

81-81770

Scalar 50 Tape Drive
Replacement Instructions

Provides information on
replacing tape drives in
the Scalar 50 library.

81-81539

TC2201 iSCSI Bridge
User’s Guide

Provides web and serial
interface information for
the TC2201 iSCSI bridge.

81-81771

Scalar 50 Magazine
Upgrade Instructions

Provides installation
information for both the
SDLT and LTO tape
magazines.

6311658

SNMP Integration Guide

Provides integration
information for SNMP.

81-81627

Scalar 50 Series
DLTSage™ Secure Tape
Quick Start Guide

Provides information on
creating secure keys on
your library.

Refer to the appropriate product manuals for information about your
tape drives and cartridges.

Quantum Scalar 50 User’s Guide

xix

Preface

SCSI-2 Specification

0

The SCSI-2 communications specification is the proposed American
National Standard for information systems, dated March 9, 1990. Copies
may be obtained from:
Global Engineering Documents
15 Inverness Way, East
Englewood, CO 80112
(800) 854-7179 or (303) 397-2740

Contacts

Quantum company contacts are listed below.
Quantum Corporate Headquarters

0

To order documentation on the DXi7500 or other products contact:
Quantum Corporation (Corporate Headquarters)
1650 Technology Drive, Suite 700
San Jose, CA 95110-1382
Technical Publications

0

To comment on existing documentation send e-mail to:
doc-comments@quantum.com

Quantum Home Page

0

Visit the Quantum home page at:
http://www.quantum.com

Getting More Information or
Help

StorageCare™, Quantum’s comprehensive service approach, leverages
advanced data access and diagnostics technologies with crossenvironment, multi-vendor expertise to resolve backup issues faster and
at lower cost.
Accelerate service issue resolution with these exclusive Quantum
StorageCare services:

Quantum Scalar 50 User’s Guide

xx

Preface

• Service and Support Website - Register products, license software,
browse Quantum Learning courses, check backup software and
operating system support, and locate manuals, FAQs, firmware
downloads, product updates and more in one convenient location.
Benefit today at: http://www.quantum.com/ServiceandSupport/
index.aspx
• eSupport - Submit online service requests, update contact
information, add attachments, and receive status updates via email.
Online Service accounts are free from Quantum. That account can
also be used to access Quantum’s Knowledge Base, a comprehensive
repository of product support information. Sign up today at: http://
www.quantum.com/ServiceandSupport/eSupport/Index.aspx.
• StorageCare Guardian - Securely links Quantum hardware and the
diagnostic data from the surrounding storage ecosystem to
Quantum's Global Services Team for faster, more precise root cause
diagnosis. StorageCare Guardian is simple to set up through the
internet and provides secure, two-way communications with
Quantum’s Secure Service Center. More StorageCare Guardian
information can be found at: http://www.quantum.com/
ServiceandSupport/Services/GuardianInformation/Index.aspx.
For further assistance, or if training is desired, contact Quantum
Technical Assistance Center:
North America:

+1-800-284-5101

UK, France and Germany

00800 4 QUANTUM

EMEA

+44 1256 848 766

For worldwide support:

Quantum Scalar 50 User’s Guide

http://www.quantum.com/ServiceandSupport/
eSupport/Index.aspx

xxi

Preface
StorageCare Guardian

StorageCare Guardian

0

StorageCare Guardian is a remote monitoring and diagnostic solution that

enables Quantum to proactively monitor the health of Quantum
products, use diagnostic data to predict possible failures, and determine
whether or not the problem involves a Quantum product or other critical
component in the environment.

Benefits

StorageCare Guardian gives the customer added assurance that Quantum

will make sure its products are running optimally to ensure maximum
operational efficiency. Deploying this solution is easy and enables
customers to minimize the costs associated with system downtime and
service issues should a problem arise.

More Reliable Backups

Faster Resolution Time

Through continuous 24x7x365 monitoring, StorageCare Guardian
proactively checks Quantum systems for common errors and alerts the
customer when a Quantum product is underperforming. By proactively
identifying red flags, the risk of failed backups and machine downtime
can be mitigated.
When the system is down, StorageCare Guardian provides the necessary
diagnostics data that enables Quantum to identify the root cause and
expedite the problem resolution process. Problems that used to take days
to fix can now be fixed in minutes. When problems require onsite
support, field engineers will have better information along with the right
parts necessary to fix the problem.

0

StorageCare Guardian allows Quantum to
• Monitor diagnostic data related to Quantum products
• Receive alarms that notify Quantum of issues at the customer site
• Run diagnostic utilities to more quickly determine the root cause of
issues

Quantum Scalar 50 User’s Guide

xxii

Preface
StorageCare Guardian

• Initiate remote connection to remote management interface to get
more in-depth information about the health of your Quantum
product.
• Distribute software/firmware upgrades - this will be available as a
future enhancement

0

Product Features

• Continuous Monitoring - Proactive 7x24x365 monitoring of Quantum
products enabling Quantum Support to be alerted on events such as
errors or marginal conditions that are defined by the user.
• Root Cause Diagnosis - Allows Quantum to quickly isolate and
identify the root cause of a problem.
• Rapid Problem Resolution- Quantum can rapidly recommend and/
or implement the corrective actions needed to resolve a problem
ensuring minimal impact to the IT environment.
• Quantum Remote Software Update - Distributed software update
capability allows fast updates to agent software and Quantum
hardware installed at customer sites
• Real-time Data Collection - Instant on-demand or scheduled
diagnostic data collection from Quantum products as well as the
ability to run user-defined data collection scripts from agent.
• Access Management - Customer has full control over Quantum's
access rights and privileges.
• Audit Logging - Audit logs are kept for all communications to and
from the agent.

0

How it works:
1 Customers can download the StorageCare Guardian agent software
from http://www.quantum.com/guardiandownload.
2 Customer installs the StorageCare Guardian agent on any Windows
2000/2003/XP or Solaris 8/9 server located at the customer’s site.

3 The StorageCare Guardian agent monitors Quantum products, and
provides information and updates to the Quantum Enterprise Server
that resides at Quantum Support.

Quantum Scalar 50 User’s Guide

xxiii

Preface
StorageCare Guardian

4 If an error or problem is detected, Quantum queues a request to the
StorageCare Guardian agent for data collection or real-time access to
the system.
5 The StorageCare Guardian agent checks access policy settings to
determine if access is allowed.
6 If approved, the information is transferred to Quantum, or a remote
connection is initiated.
7 Quantum Support will diagnose the problem and, if necessary, send
the needed parts and/or field personnel to resolve the issue.
8 Quantum can identify if the backup problem is not associated with
the Quantum device and then direct the customer to resolve the issue
with appropriate third-party vendor.

Quantum Scalar 50 User’s Guide

xxiv

Chapter 1

1

Library Description

This chapter provides an overview of the Scalar 50 and is divided into
the following sections:
• Overview
• Tape Drives
• Library Features
• DLTSage™ Tape Security
• Mixed Media Support
• Capacity on Demand
• Library Scalability (Stacked Configurations)
• Getting Started

Quantum Scalar 50 User’s Guide

1

Chapter 1 Library Description
Overview

Overview
The Quantum Scalar 50 tape library (see figure 1) is an automated tape
storage and retrieval device that may consist of up to 4 tape drives and up
to 32 SDLT or 38 LTO tape cartridges. Cartridges are stored in two
removable cartridge magazines and two fixed slots. Both SDLT and LTO
tape cartridges can be installed in a single library as long as the
appropriate magazines and drives are installed.

Figure 1 Scalar 50

# Tape
Drives

Quantum Scalar 50 User’s Guide

# Magazines

# Fixed
Slots

#
Cartridges

SDLT

0-2

2 (15 slots per
magazine)

2

32

LTO

0-4

2 (18 slots per
magazine)

2

38

2

Chapter 1 Library Description
Overview

Figure 2 Slot Numbering,
Scalar 50 SDLT

Mag 1

0000

0005

0010

0001
0002

0006
0007
0008
0009

0011
0012
0013
0014

0003
0004

Tape
drive 1

Tape
drive 2

Hand

SDLT magazines have 15 cartridges

Quantum Scalar 50 User’s Guide

Fixed cartridge slots

0020
0021

0025

0022
0023
0024

0027
0028

0026

Mag 2

0030
0031

Top
0015
0016
0017
0018
0019

0029

3

Chapter 1 Library Description
Overview

Figure 3 Slot Numbering,
Scalar 50 LTO

Mag 1

0000
0001
0002
0003
0004
0005

0006
0007
0008
0009
0010
0011

0012
0013
0014
0015
0016
0017

Tape
drive 1

Tape
drive 2

Hand

LTO magazines have 18 cartridges

Quantum Scalar 50 User’s Guide

Fixed cartridge slots

0018
0019
0020
0021
0022
0023

0024
0025
0026
0027
0028
0029

0030
0031
0032
0033
0034
0035

Mag 2

0036
0037

Top

4

Chapter 1 Library Description
Tape Drives

Tape Drives
Scalar 50 tape libraries are equipped with either SCSI or native Fibre
Channel tape drives. SCSI buses are SCSI-2 fast/wide (8/16 bit), Ultra 3
SCSI, Ultra 160, or Ultra 320 SCSI, depending on the drives installed.
LVD SCSI configurations have a maximum allowable bus length of 12
meters. To determine the cable length of the bus, measure the lengths of
the SCSI cables connecting each device to that bus and add those lengths
together. To that total length, add 12.25 inches (31.10 cm) for the internal
SCSI cable length of each SCSI tape drive.
Tape Drive Types

1

The Scalar 50 tape library support the following tape drives:
• Quantum DLT-S4 (SCSI and Native Fibre Channel)
• Quantum Half-Height LTO-3 (SCSI and Native Fibre Channel)
• HP LTO-3 (SCSI and Native Fibre Channel)
• HP LTO-4 (SCSI and Native Fibre Channel)
• HP Half-Height LTO-4 (SAS)
Scalar 50 library can support mixed media types, mixed interface types
(Fibre Channel and SCSI) as well as mixed form factors within the same
library. Example: The Scalar 50 can contain both LTO full height drives
with LTO half-height drives in the same library.
Refer to the following tables for tape drive performance characteristics.
Both SDLT and LTO tape drive can exist in the same library as long as the
appropriate magazines are installed in the library.

Table 1 DLT-S4 Performance
Characteristics

Quantum Scalar 50 User’s Guide

Quantum Scalar 50 DLT-S4 Model (drives/slots)

2/32

Capacity in Terabytes (TB) (800 GB per cartridge)

25.6

*Compressed Capacity in TB (1600 GB per cartridge)

51.2

Throughput (GB/hr) based on 60 MB/sec transfer rate
(2 tape drives installed)

432

*Compressed Throughput (GB/hr) based on 120 MB/
sec transfer rate (2 tape drives installed)

864

5

Chapter 1 Library Description
Tape Drives

* Compressed capacity assumes a 2:1 compression ratio.

Table 2 Quantum LTO-3 (HalfHeight) Performance
Characteristics

Quantum Scalar 50 Quantum LTO-3 Half-Height Model
(drives/slots)

4/38

Capacity in Terabytes (TB) (400 GB per cartridge)

15.2

*Compressed Capacity in TB (800 GB per cartridge)

30.4

Throughput (TB/hr) based on 80 MB/sec transfer rate (4
tape drives installed)

1.1

*Compressed Throughput (TB/hr) based on 160 MB/sec
transfer rate (4 tape drives installed)

2.3

* Compressed capacity assumes a 2:1 compression ratio.

Table 3 HP LTO-3 (Full Height)
Performance Characteristics

Quantum Scalar 50 HP LTO-3 Model (drives/slots)

2/38

Capacity in Terabytes (TB) (400 GB per cartridge)

15.2

*Compressed Capacity in TB (800 GB per cartridge)

30.4

Throughput (TB/hr) based on 80 MB/sec transfer rate (2
tape drives installed)

.576

*Compressed Throughput (TB/hr) based on 160 MB/sec
transfer rate (2 tape drives installed)

1.1

* Compressed capacity assumes a 2:1 compression ratio.

Quantum Scalar 50 User’s Guide

6

Chapter 1 Library Description
Tape Drives

Table 4 HP LTO-4 (HalfHeight) Performance
Characteristics

Quantum Scalar 50 HP LTO-4 Half-Height Model
(drives/slots)

1/38

Capacity in Terabytes (TB) (800 GB per cartridge)

30.4

*Compressed Capacity in TB (1600 GB per cartridge)

60.8

Throughput (TB/hr) based on 80 MB/sec transfer rate (4
tape drives installed)

1.1

*Compressed Throughput (TB/hr) based on 160 MB/sec
transfer rate (4 tape drives installed)

2.3

* Compressed capacity assumes a 2:1 compression ratio.

Table 5 HP LTO-4
Performance Characteristics

Quantum Scalar 50 HP LTO-4 Model (drives/slots)

2/38

Capacity in Terabytes (TB) (800 GB per cartridge)

30.4

*Compressed Capacity in TB (1600 GB per cartridge)

60.8

Throughput (TB/hr) based on 120 MB/sec transfer rate (2
tape drives installed)

.864

*Compressed Throughput (TB/hr) based on 240 MB/sec
transfer rate (2 tape drives installed)

1.7

If a drive experiences read/write errors when the AutoClean function is
enabled, the library issues an error message stating that drive cleaning is
required. Without user intervention, the library hand replaces the data
cartridge with a cleaning cartridge. When the cleaning procedure
finishes, the library hand returns the data cartridge to the drive.
Note:

Quantum Scalar 50 User’s Guide

When a cleaning cartridge has completed its 20-use limit, it is
automatically exported from the library, requiring a new one
to be loaded through the load port.

7

Chapter 1 Library Description
Library Features

Library Features
Front Panel

1

Figure 4 illustrates the features of the Scalar 50 library front panel.
These features are described in table 6.

Figure 4 Scalar 50 Front Panel

Scalar 50

Operator control panel (OCP)

Quantum Scalar 50 User’s Guide

8

Chapter 1 Library Description
Library Features

Table 6 Front Panel Features

Feature

Description

Operator
control panel
(OCP)

The operator control panel consists of the following elements:
• OCP display

The OCP displays library status information and allows you to
access the library menus. These menus allow you to view or
change the library settings and run diagnostic tests.
The OCP is discussed in detail in chapter 2.

• Five OCP
buttons

These buttons in combination with the OCP are used to scroll
through screens and select options or commands. The
functionality of these buttons changes depending on the
currently displayed OCP screen. The power button is used to
turn the library on and off.

• Light emitting
diode (LED)
indicator

The operator control panel has one LED indicators:
• Steady green - indicates a idle state
• Flashing green - indicates a busy state
• Flashing amber - indicates an attention state
• Steady amber - indicates an error

Magazine
access doors

These doors protect the data cartridge magazines.

Quantum Scalar 50 User’s Guide

9

Chapter 1 Library Description
Library Features

Internal Layout

1

Figure 5 illustrates the internal layout of a Scalar 50 library.

Figure 5 Scalar 50 Internal
Layout

Elevator
2 fixed bins

Right cartridge
magazine

Tape drives

Left cartridge
magazine

Hand

Quantum Scalar 50 User’s Guide

10

Chapter 1 Library Description
Library Features

Each cartridge magazine holds 15 SDLT cartridges or 18 LTO cartridges.
The bins in the left magazines are numbered from 1 through 15 (18 in
LTO libraries) from front to back. The bins in the right magazines are
numbered from 1 through 15 (18 in LTO libraries) from back to front. The
Scalar 50 has two fixed slots behind the right magazine.
A bar code reader is attached to the library’s robotic hand. This bar code
reader automatically identifies the cartridges in the library, if the
cartridges are fitted with acceptable bar code labels.

Back Panel

1

The library back panel provides access to the following items:
• System Controller Board (SCB)
• Power Supplies
• CPCI Card Cage
• Tape Drives

1

System Controller Board (SCB)

The system controller board (SCB) contains the library firmware and
processor. Two Ethernet ports. One port for remote management and the
other for internal communications with add-on CPCI cards such as the
TC2201 iSCSI bridge.

1

Power Supplies
The power supplies provide redundant power to the library. The Scalar
50 can contain up to two power supplies (one power supply in the base
unit).

1

CPCI Card Cage
The CPCI (compact PCI) card cage provides space for option cards such
as the TC2201 iSCSI bridge. The Scalar 50 can contain one option card.

Quantum Scalar 50 User’s Guide

11

Chapter 1 Library Description
Library Features

1

Tape Drives
The Scalar 50 can contain up to four tape drives.
Warning: Hazardous Moving Parts.
Keep Fingers and Other Body
Parts Away When Removing
and Installing Tape
Drives.



Warnung: Gefährliche bewegliche
Teile. Halten Sie die
Finger und andere
Körperteile weg, wenn
Sie Bandlaufwerke
entfernen und
anbringen.

Figure 6 illustrates the back panel of the Scalar 50 library.

Figure 6 Scalar 50 Back Panel
System controller board

Power supply

Quantum Scalar 50 User’s Guide

Power connectors

CPCI card cage

Tape
drives

12

Chapter 1 Library Description
DLTSage™ Tape Security

DLTSage™ Tape Security
The Scalar tape library with DLT-S4 tape drives are capable of utilizing
DLTSage Tape security. DLTSage Tape Security is a unique solution
designed to prevent unauthorized access to tape cartridges which is
particularly valuable when protecting tapes that are transported offsite.
DLTSage Tape Security is a firmware feature designed into the DLT-S4
tape drive which uses an electronic key to prevent or allow reading and
writing of data on to a tape cartridge. This key is managed through the
remote management pages of the Scalar 50 tape library (see chapter 3,
“Quantum Scalar 50 Remote Management,”). DLTSage Tape Security is
available at no additional cost as an integrated feature in of the DLT-S4
tape drive and Scalar 50 tape library.

Mixed Media Support
The Scalar 50 tape library is capable of supporting mixed media (SDLT
and LTO media) and a mixture of tape drives in the same library frame.
You must have at least one magazine type (SDLT or LTO) for each tape
drive type (SDLT or LTO).

Capacity on Demand
Capacity on demand provides the ability to upgrade the storage capacity
of a library by using a software capacity key that grants access to
additional magazine slots. The Scalar 50 library has two capacity levels
(see table 7):
• Level 1 - default capacity (four magazine columns starting with the
three columns of the left-hand magazine and including the back
column of the right-hand magazine)
• Level 2 - full capacity (all six columns of the left and right magazines
and all physical slots in the system including stacked libraries)
Quantum Scalar 50 User’s Guide

13

Chapter 1 Library Description
Capacity on Demand

The two fixed slots located in every library are always available for use.

Table 7 Scalar 50 Capacity
Levels

Licensed Capacity (Slot Count)
Capacity Level

LTO

SDLT

Level 1

26

22

Level 2

38

32

Note:

Partitioning cannot be used unless all libraries are at FULL
capacity.

Note:

If your libraries are in a stacked configuration, all libraries
must be at FULL capacity. PX502 libraries are automatically at
full capacity.

Contact your Quantum Sales representative to acquire additional license
keys.

Enabling Capacity on
Demand

1

If your Quantum Scalar 50 has not already been enabled with the full slot
capacity, you must complete the following procedure:
1 Retrieve and record the Scalar 50 library serial number.
2 Access the COD website and follow the instructions by providing the
Library serial number to obtain your new License Key for your
additional capacity purchase.
The COD website URL is: www.quantum.com/capacity/scalar50.
3 Record your new License Key and then install it into the Library to
increase your slot capacity (see Library on page 101 for more
information on enabling capacity on demand).

Quantum Scalar 50 User’s Guide

14

Chapter 1 Library Description
Library Scalability (Stacked Configurations)

Library Scalability (Stacked Configurations)
The Scalar 50 library modules can be used as stand-alone libraries, or
combined with other Scalar 50 library modules in a standard 19-inch rack
to form a larger library system (called a multiple library stack). The
multiple library or stacked configuration appears as a single large
capacity library (or multiple libraries if partitioned) to the host (see
figure 7).

Multiple Library Stack
Requirements

Quantum Scalar 50 User’s Guide

To ensure the proper operation of your multiple library stack, review the

1 following list of multiple library stack requirements:
•

Multiple library stacks that contain a Scalar 50 can NOT exceed two
library cabinets.

•

The Scalar 50 must be the Master library in a multiple library stack
containing PX502 libraries.

•

The Master library must always be in the bottom most position in the
library stack.

•

If a Scalar 50 is stacked with PX502 libraries, the PX502 can NOT
contain an HP LTO-2 tape drive or a FC1202 Fibre Channel bridge.
These devices are not supported by Scalar 50.

•

All Scalar 50 libraries must have full capacity enabled.

•

A library that contains SAS drives cannot be shared with SCSI or
Fibre Channel libraries.

•

If your Scalar 50 is not already enabled with full slot capacity, you
must initially configure the Scalar 50 libraries and enable Full
capacity with a Capacity Key before configuring the cabinets as
Master and Slave libraries (see Library on page 125 for more Capacity
Key information).

15

Chapter 1 Library Description
Library Scalability (Stacked Configurations)

Figure 7 Multiple Library
Stack (Cross Section

Bottom hand lifting pass
through into top library
Pass through in top
library

Top hand

Table 8 lists the capacities of all the sizes of multiple library
stacks created using LTO Scalar 50 library modules. Table 9 lists
the capacities of all the sizes of multiple library stacks created
using SDLT Scalar 50 library modules.

Quantum Scalar 50 User’s Guide

16

Chapter 1 Library Description
Library Scalability (Stacked Configurations)

Table 8 Capacity, Scalar 50
Multiple Library Stack - LTO
(42U High Rack)

# of
Cartridges*
# of Scalar
50 Library
Modules

Capacity (in TB)
Quantum/HP LTO Gen 3

Max. # of
Tape Drives

HP LTO Gen 4

LTO

Native

Compressed†

Native

Compressed†

1

2 full height/
4 half height

38

15.2

30.4

32

64

2

4 full height/
8 half height

76

28.8

57.6

64

128

*.The values in the # of Cartridges and Capacity columns assume that all the magazines and fixed cartridge slots are fully
populated with data cartridges.
†Compressed values assume 2:1 compression ratios.

Table 9 Capacity, Scalar 50
Multiple Library Stack - SDLT
(42U High Rack)

# of
Cartridges*
# of Scalar
50 Library
Modules

Capacity (in TB)*
DLT-S4

Max. # of
Tape Drives

SDLT

Native

Compressed†

1

2 full height/
4 half height

32

26.4

52.8

2

4 full height/
8 half height

64

52.8

105.6

*.The values in the # of Cartridges and Capacity columns assume that all the magazines and fixed cartridge slots are fully populated
with data cartridges.
†Compressed values assume 2:1 compression ratios.

Quantum Scalar 50 User’s Guide

17

Chapter 1 Library Description
Getting Started

Getting Started
This chapter describes the procedures necessary to get your Quantum
Scalar 50 library up and running. Have the following equipment and
accessories available before installing the library:
• SCSI cables to support 1 host bus adapter (HBA) per two tape drives
• SCSI, SAS, or Fibre Channel HBAs in the host
•

2 tape drives per SCSI bus

Note:

Quantum ships sufficient SCSI cables and terminators
with the libraries to set up two-drives per SCSI bus. One
tape drive per SCSI bus may be necessary for optimum
performance. Refer to your tape drive documentation.

• Power source (see appendix A on page 177 for power requirements)
• Tape cartridges (LTO and/or SDLT)
After the Quantum Scalar 50 is in it’s final location, the following steps
are required to complete the installation:
• Installing the Quantum Scalar 50
• Cabling the Quantum Scalar 50 Series
• Loading Tape Cartridges
• Initial Configuration

Installing the Quantum
Scalar 50

The Scalar 50 library modules fit into a standard 19-inch wide rack. Refer

1 to figure 8 for rack space requirements. Complete mounting information
is provided in the Quantum Scalar 50 Series Quick Start (PN 81-81767).

Quantum Scalar 50 User’s Guide

18

Chapter 1 Library Description
Getting Started

Figure 8 Rack Space
Requirements

1 Scalar 50 library
module (4U)

Hole pattern
Top of rack
.312 in (7.92 m m)
.625 in (15.9 mm)
.625 in (15.9 mm)
.5 in (12.7 mm)
.625 in (15.9 mm)
.625 in (15.9 mm)
.5 in (12.7 mm)
*1U = 1.75 in (44.45 mm)

Warning:

Cabling the Quantum
Scalar 50 Series

1

If the rack is empty at the time of installation, do NOT
install the Scalar 50 modules too high in the rack. The
combined weight of the components may cause the rack
to become “top heavy” and unstable if installed in the top
of an empty rack. If installing a multiple library stack,
begin installing the bottom library module first.

After the Quantum Scalar 50 is in its final location, the tape drives and
system controller board must be connected to the backup host system(s).
To cable the Quantum Scalar 50:

Quantum Scalar 50 User’s Guide

19

Chapter 1 Library Description
Getting Started

1 The Scalar 50 tape drives and system controller board are accessed
from the back of the library (refer to Connecting to Host
Workstations on page 31).
2 Connect Ethernet port located on the back of the library on the
system controller board to the local area network (see figure 9).

Ethernet port

Figure 9 Connecting the
Library to the Local Area
Network

Loading Tape Cartridges 1

Initial Configuration

1

Quantum Scalar 50 User’s Guide

Internal communication
with TC2201 CPCI card

System controller board

Before operating the library, load the appropriate tape cartridges (LTO or
SDLT) into the library starting with the left-hand magazine (see figure 2
and figure 3 for slot locations).

The Quantum Scalar 50 must be initially configured with an IP address
before the remote management software is available. Refer to Using the
OCP on page 37 for information on configuring your Scalar 50 network
information and preparing for operation.

20

Chapter 2

2

Basic Library Operations

This chapter describes the following basic library operating procedures:
• Installing Tape Cartridges
• Preparing the Library for Operation
• Turning the Library On and Off
• Using the OCP
• Load Port Configuration

Installing Tape Cartridges
To install tape cartridges:
1 Label each cartridge (see “SDLT Cartridges” on page 24 and “LTO
Cartridges” on page 26 for information on cartridge labels).
2 Set the write-protect switch to either write protect or write enable
(see “SDLT Cartridges” on page 24 and “LTO Cartridges” on
page 26 for information on write-protect switches).

Quantum Scalar 50 User’s Guide

21

Chapter 2 Basic Library Operations
Installing Tape Cartridges

3 Place cartridges (right side up) in the fixed slots and magazines:
a Open the library doors (see “Library Operations” on page 45 to
open the library doors).
b

Remove the magazines (see “Library Operations” on page 45 to
release the magazines).

Note:

You have approximately 10 seconds to open the doors and
remove the magazines. If you did not complete the
operation, repeat the steps.

Load the tape cartridges in the magazines and fixed bins. It is
recommended to start loading tape cartridges in magazine 1, bin
0000 (see figure 2 on page 3 and figure 3 on page 4 for magazine
and bin locations).

c

Warning:

Quantum Scalar 50 User’s Guide

Do NOT reach into the library to load tape cartridges
into the fixed bins. Use the Move page located on the
Operations tab from the remote management pages
(see chapter 3 on page 63) to move tape cartridges
from the magazines into the fixed bins.

d

Replace the magazines in the library.

e

Close the library doors.
Caution:

Placing the cartridges in the bins upside down can
cause damage to the library (see figure 11 for SDLT
cartridges and figure 12 for LTO cartridges).

Caution:

Handle tape cartridges with care. Do not drop or bang
them, or place them near sources of electromagnetic
interference. Rough handling can displace the tape
leader, making the cartridge unusable and potentially
hazardous to the tape drives. If a tape is dropped,
discard and replace with a new tape. Loss of data
could result from damaged tape cartridges inserted in
tape drives.

22

Chapter 2 Basic Library Operations
Installing Tape Cartridges

Taking ESD Precautions 2

Components within the Scalar 50 contain static-sensitive parts. To
prevent damage to these parts while performing installation,
maintenance, or replacement procedures, observe the following
precautions:
• Keep the cabinet turned off during all installation, maintenance, and
replacement procedures.
• Keep the cabinet power cord connected to a grounded power outlet
except when working with AC electrical components.
Warning:

Avoid contact with the power supplies, EMI filter, and all
other AC electrical components while the cabinet is
connected to a power outlet.


Unplug all AC cords to remove power from equipment.

• Use an antistatic wrist strap when touching internal cabinet
components. To use the wrist strap properly, place the band around
your wrist and attach the clip to the cabinet frame. Keep the strap on
until you are ready to close the cabinet doors.
• Keep static-sensitive parts in their shipping containers until ready for
installation.
• Do not place static-sensitive parts on any metal surface. If you need to
put down a static-sensitive part, place it inside its protective shipping
bag or on a grounded antistatic mat.
• Avoid direct contact with static-sensitive parts. Avoid touching
connectors and discrete components.
• Close cabinet door and access panel when not working on the
cabinet.

Quantum Scalar 50 User’s Guide

23

Chapter 2 Basic Library Operations
Installing Tape Cartridges

• Be very careful when installing the cabinet or handling components
in dry climates or environments where cold weather heating is used.
Environments such as these with lower relative humidity have
greater potential to produce static electricity.
Note:

SDLT Cartridges

2

In environments with high potential for static electricity,
take additional precautions such as the use of an antistatic
smock or a grounded antistatic mat.

The following section shows you how to label SDLT tape cartridges, as
well as setting the write-protect switch and proper orientation.
Note:

Quantum highly recommends using barcode labels provided
by Quantum. Also, use the appropriate barcode labels for your
drive type. Do not use older barcode labels on tape cartridges
for newer drive types.

2

Labeling

The Scalar 50 is a multi-media library, meaning multiple drive and tape
cartridge types can be present in a single library. Barcode labels are
attached to each tape cartridge to differentiate the different tape cartridge
types (SDLT, LTO, and cleaning cartridges).
The SDLT cartridge label has eight characters (e.g. AAANNNS#). The
first six characters are called the volume identifier which is made up of
three alpha characters and three numeric characters. These characters
allow each cartridge to have a unique identifier. The last two characters
are called the media identifier and indicate the following media types:
• V4 = DLT-V4
• S1 = SDLT 220
• S2 = SDLT 320
• S3 = SDLT 600
• S4 = DLT-S4

Quantum Scalar 50 User’s Guide

24

Chapter 2 Basic Library Operations
Installing Tape Cartridges

Note:

You cannot choose the sequence of labels inside the bar code
label packs. No two packs are ever the same to avoid issues
with duplicate bar code IDs.

Place the label in the slide-in slot on the front of the cartridge (see
figure 10).

Figure 10 Inserting a Barcode
Label (SDLT)

Slide-in slot

Note:

Only use barcode labels that have been designed for
cartridges. Do not adhere labels to a cartridge anywhere
except the slide-in slot.

Setting the Write-Protect Switch

2

Each tape cartridge has a write-protect switch similar to that shown in
figure 11. This switch determines whether new data can be written to the
cartridge (write-enabled) or whether data on the cartridge is protected
from being erased or overwritten (write-protected). Set the write-protect
switch to enabled when inserting new cartridges into the library. Set the
write-protect switch to protected archiving tape cartridges.

Quantum Scalar 50 User’s Guide

25

Chapter 2 Basic Library Operations
Installing Tape Cartridges

2

Proper Insertion Orientation
Refer to figure 11 for proper label placement, write protection settings
and insertion orientation.

Figure 11 SDLT Cartridges

Ins

Insertion arrow

ert

thi
s

en
di

nto

the

s lo
t

Barcode label

Orange
window

Write
protect

Slide left

LTO Cartridges

2

Slide right (default)

(SDLT cartridge shown)

LTO tape cartridges are different in size to the SDLT cartridges as well as
in the barcode labeling and write-protect switch setting (see figure 12).
Note:

Quantum Scalar 50 User’s Guide

Write
enable

Quantum highly recommends using barcode labels provided
by Quantum. Also, use the appropriate barcode labels for your
drive type. Do not use older barcode labels on tape cartridges
for newer drive types.

26

Chapter 2 Basic Library Operations
Installing Tape Cartridges

2

Labeling

The Scalar 50 is a multi-media library, meaning multiple drive and tape
cartridge types can be present in a single library. Barcode labels are
attached to each tape cartridge to differentiate the different tape cartridge
types (SDLT, LTO, and cleaning cartridges).
The LTO cartridge label has eight characters (e.g. AAANNNL#). The first
six characters are called the volume identifier which is made up of three
alpha characters and three numeric characters. These characters allow
each cartridge to have a unique identifier. The last two characters are
called the media identifier and indicate the following media types:
• L1 = LTO generation 1 (LTO)
• L2 = LTO generation 2 (LTO-2)
• L3 = LTO generation 3 (LTO-3)
• L4 = LTO generation 4 (LTO-4)
Note:

You cannot choose the sequence of labels inside the bar code
label packs. No two packs are ever the same to avoid issues
with duplicate bar code IDs.

Adhesive-backed barcode labels are used on LTO tape cartridges. Refer
to figure 12 for proper label placement, write protection settings and
insertion orientation.

Quantum Scalar 50 User’s Guide

27

Chapter 2 Basic Library Operations
Installing Tape Cartridges

Figure 12 LTO Cartridges

I ns

Slide left (default)

ert

Insertion arrow

thi
s

en

di

nto

the

slo
t

Write
enable

Write
protect
Slide right

Barcode label

A B C 1 2 3 L 1
Caution:

Cleaning Cartridges

2

Cleaning cartridges are used when a tape drive within the library
requires cleaning. When Autoclean is enabled (either through the OCP or
remote management screens), the library will automatically clean the
tape drive when needed. A fixed bin (see figure 2 on page 3 and figure 3
on page 4 for bin locations) is generally used to store a cleaning cartridge,
however, the cartridge can be placed anywhere in the library. When the
library completes the inventory, the system stores the cleaning cartridge
location so it will be available when a tape drive requires cleaning.
Note:

Quantum Scalar 50 User’s Guide

LTO tape drive media cannot be degaussed due to the fact
that it uses "magnetic servos." Do not attempt to degauss
LTO tape drive media. If this media is degaussed, it will
no longer work.

You must attach the appropriate cleaning cartridge barcode
label (SDLT or LTO) to the cleaning cartridge or the library
will mark it as unrecognizable media.

28

Chapter 2 Basic Library Operations
Installing Tape Cartridges

SDLT and LTO cleaning cartridge labels begin with CLN (see figure 13
for SDLT and figure 14 for LTO):
• SDLT cleaning cartridge labels are in the following format:
CLN###S#
• LTO cleaning cartridge tables are in the following format:
CLN###L#

Figure 13 SDLT Cleaning
Cartridges

Figure 14 LTO Cleaning
Cartridges

Quantum Scalar 50 User’s Guide

29

Chapter 2 Basic Library Operations
Preparing the Library for Operation

Preparing the Library for Operation
To prepare the cabinet for operation:
• Close the Cabinet Doors and Access Panels
• Connecting to Host Workstations

Close the Cabinet Doors
and Access Panels
2

The Scalar 50 library has doors covering the tape cartridge magazines.
1 Close the front doors until they latch (see figure 15)

Figure 15 Closing the Scalar
50 Front Doors

Left door

Right door

Quantum Scalar 50 User’s Guide

30

Chapter 2 Basic Library Operations
Preparing the Library for Operation

Connecting to Host
Workstations

2

Connect the SCSI, SAS or Fibre Channel cables as shown in the following
figures:
• Scalar 50 Cable Configuration (SCSI Full Height Drives)
• Scalar 50 Cable Configuration (Native Fibre Channel Full Height
Drives)
• Scalar 50 Cable Configuration (SCSI Half-Height Drives)
• Scalar 50 Cable Configuration (SAS Half-Height Drives)
• Scalar 50 Cable Configuration (Native Fibre Channel Half-Height
Drives)
Note:

Quantum ships sufficient SCSI cables and terminators with the
libraries to set up two-drives per SCSI bus.

Caution:

The SCSI cables used to connect to the library system
controller board MUST have an offset connector. Using a
straight-in SCSI connector may damage the system
controller board.

Stacked Configuration

2

• Scalar 50 Cable Configuration (Stacked)

Quantum Scalar 50 User’s Guide

31

Chapter 2 Basic Library Operations
Preparing the Library for Operation

Figure 16 Scalar 50 Cable
Configuration (SCSI Full Height
Drives)
Ethernet

SCSI host

System Controller Board

Tape drive 2

Tape drive 1

Back of Library

Power

Figure 17 Scalar 50 Cable
Configuration (Native Fibre
Channel Full Height Drives)
Ethernet

Fibre Channel host/SAN

Tape drive 2

LTO Tape drives
shown. SDLT drives
have a single FC port

Quantum Scalar 50 User’s Guide

Power

Fibre Channel
host/SAN

Back of Library

Tape drive 1

Fibre Channel
host/SAN

32

Chapter 2 Basic Library Operations
Preparing the Library for Operation

Figure 18 Scalar 50 Cable
Configuration (SCSI HalfHeight Drives)
Ethernet

SCSI host

SCSI System Controller Board

Back of Library

Terminator

Tape drives
3 and 4

Power

SCSI host

SCSI host

Terminator

Tape drives
1 and 2

SCSI host

Figure 19 Scalar 50 Cable
Configuration (SAS Half-Height
Drives)
Surrogate Mode System
Controller Board ONLY

Ethernet

Tape drives
1 and 2

Tape drives
3 and 4

Power

Quantum Scalar 50 User’s Guide

Back of Library

SAS hosts

SAS hosts

33

Chapter 2 Basic Library Operations
Preparing the Library for Operation

Figure 20 Scalar 50 Cable
Configuration (Native Fibre
Channel Half-Height Drives)
Ethernet

Back of Library

Fibre Channel host/SAN

Tape drives
3 and 4

Power

Quantum Scalar 50 User’s Guide

Fibre Channel
host/SAN

Tape drives
1 and 2

Fibre Channel
host/SAN

34

Chapter 2 Basic Library Operations
Preparing the Library for Operation

Figure 21 Scalar 50 Cable
Configuration (Stacked)

Scalar 50 (slave library)

Tape
drive 2

Tape
drive 1

Host computer

Host computer
Scalar 50 (master library)

Ethernet

Tape
drive 2

Tape
drive 1

The library
host and
Ethernet
network are
connected only
to the Master
library.

Quantum Scalar 50 User’s Guide

35

Chapter 2 Basic Library Operations
Turning the Library On and Off

Turning the Library On and Off
This section explains:
• Turning On the Library
• Turning Off the Library
• Placing the Library On-line or Off-line

Turning On the Library 2

To turn on the library:
1 Verify that:
•

Power cables are firmly in place

•

All doors are closed

2 Push the power button located in the lower left-hand corner of the
OCP (see figure 22).
During the power up sequence, the library performs an inventory.
The power up sequence can take several minutes.

Figure 22 Turning On the
Library

OCP

Power button

Quantum Scalar 50 User’s Guide

36

Chapter 2 Basic Library Operations
Using the OCP

Turning Off the Library 2

To turn off the library:
1 Push the power button located on the front of the library and hold for
approximately 1 second (see figure 22).
The library begins the shutdown sequence. The shutdown sequence
can take up to two minutes to complete.

Placing the Library Online or Off-line
2

With the library turned on, press the button corresponding to Ops on the
OCP to access the Operations screen. Select Library Operations and then
Library on/offline to turn the library off-line. Select Yes or No to confirm
the library state change. For more information on the Operations screen,
see “Library Operations” on page 45.

Using the OCP
The operator control panel (OCP) is located on the front of the library.
The menus on the OCP allow you to obtain information about the library,
execute library commands, and test library functions. Before using the
OCP to perform library functions, familiarize yourself with the:
• Home Screen
• OCP Buttons

Home Screen

2

Quantum Scalar 50 User’s Guide

The first screen the OCP displays after library initialization is the main
screen. This screen displays library status and provides information on
the number of tape drives, slots, and serial number (see figure 23).

37

Chapter 2 Basic Library Operations
OCP Components

Figure 23 OCP Home Screen

Quantum Scalar 50

To select this
function

Press this
button
Power
button

OCP Buttons

Library
status

Button
labels

Push
buttons

2 At the bottom of each OCP screen are four button labels. These labels

indicate the functions of the four push buttons below the OCP. To select a
function, press the push button directly below the button label on the
OCP screen. The OCP also contains a power button for turning the library
on and off.

OCP Components
The OCP allows the user to perform various functions on the Quantum
Scalar 50 library. Figure 24 provides a list of the OCP functionality
available from the Home screen.

Quantum Scalar 50 User’s Guide

38

Chapter 2 Basic Library Operations
OCP Components

Figure 24 OCP Component
Tree

Info menu
Overview
Firmware Information
Firmware revision
Date and time of rev.
Network Information
IP address
Network Mask
Gateway
Hardware Information
System
Doors
Power Supply
Robotics
OCP
Drives
Event Logs
Hard Events
Soft Events
Code Update Events
Boot Events
Statistics
ElapsTm
Pcycles
SlotGet
SlotPut
SltRetG
SltRetP
DrvGet
DrvPut
DrvRetG
DrvRetP

Quantum Scalar 50 User’s Guide

Ops menu
Library Operations
Library on/offline
Release Magazines
Park for Shipping
Find Tape
Search for label
Search for media ID
MoveTape
Left mag(s)
Right mag(s)
Drives
Hand/Top Passthru
Drive Operations
Drive(s)
Pwr on
Pwr off
reset
Drive Type
Serial Number
Firmware Revision
Scan Inventory
DrvLdR
DrvUnlR
XYmove
Zmove
Pmove
Rmove
XYretry
Zretry
Pretry
Rretry

Setup menu
Cabinet
Host bus
Stack role
Left load port
Right load port
Drive FUP from tape
Full Inventory
Partitions
Barcode swap
Emulation
Auto clean
Configure Slots
Security
Set admin PIN
Set operator PIN
Network
DHCP
IP address
Subnet mask
Default gateway
Ethernet 0

Diags menu
System-level tests
Health test
Self test
Calibration stats
Random load/unload
Random (slots only)
Random (drive focus)
Sequential bins
Sequential drives
Subsystem tests
XYZ test
Hand assembly test
Component tests
XY test
Z test
Rotation stats
Translation test
Camera test
Temperature test
Home position

Date and Time
Time zone
Standard time
Daylight savings time

39

Chapter 2 Basic Library Operations
OCP Components

The following sections provide information on each function available
from the Quantum Scalar 50 OCP:
• Info Screen
• Operations Screen
• Setup Screen
• Diags Screen

Info Screen

2

The Info screen provides access to library information such as hardware
status, event logs, and statistics.
To access the Info screen, press Info from the Home screen. The OCP
displays the Info screen (see figure 25):

Figure 25 Info Screen

Enter

The Info screen provides the following choices:
• Overview Information
• Hardware Information
• Event Logs
• Statistics Information

Quantum Scalar 50 User’s Guide

40

Chapter 2 Basic Library Operations
OCP Components

2

Overview Information
To view overview information:
1 From the Info screen, use the up and down arrows to highlight
Overview and press Enter.
The Overview screen displays (see figure 26):

Figure 26 Overview Screen

The Overview screen displays the following information about the
library:
•

Firmware revision

•

Time and date the firmware was built

2 Press Back or Next to review the network information such as the
current IP address, network mask, and gateway information.
3 When you are finished viewing overview information, press Exit to
return to the Info screen.

Quantum Scalar 50 User’s Guide

41

Chapter 2 Basic Library Operations
OCP Components

Hardware Information

2

To view hardware information:
1 From the Info screen, use the up and down arrows to highlight
Hardware and press Enter.
The Hardware screen displays (see figure 27):

Figure 27 Hardware Screen

Exit

The Hardware screen displays the following information (see
table 10):

Table 10 Hardware
Information

Quantum Scalar 50 User’s Guide

Hardware
Information

Description

System

System information displays the overall sensor
details for the library.

Doors

Door information displays the door sensor details.

Power Supply

Power supply information displays the power
supply sensor details.

Robotics

Robotics information displays the robotic sensor
details.

OCP

OCP information displays the OCP sensor details.

Drives

Drives information displays the tape drive sensor
details.

42

Chapter 2 Basic Library Operations
OCP Components

2 Use the up and down arrows to highlight the information you wish
to display and press Enter.
3 When you are finished viewing the hardware information, press Exit
to return to the Info screen.
Event Logs

2

To view the event logs:
1 From the Info screen, use the up and down arrows to highlight Event
Logs and press Enter.
The Event Log screen displays (see figure 28).

Figure 28 Event Log Screen

Exit

2 Use the up and down arrows to highlight the event type you wish to
view (Hardware, Software, Code updates, or Boot events).
The OCP displays the event severity list.
3 Use the up and down arrows to highlight the severity type you wish
to view (All, Critical, Warning, and Informational).
The OCP displays the event or list of events in the specific severity
category. Use the Back and Next buttons to move between events.
4 When you are finished viewing the event logs, press Exit to return to
the Info screen. Refer to chapter 4 on page 137 for detailed event
information.
Statistics Information

2

To view statistics information:
Quantum Scalar 50 User’s Guide

43

Chapter 2 Basic Library Operations
OCP Components

1 From the Info screen, use the up and down arrows to highlight
Statistics and press Enter.
The Statistics screen displays (see figure 29):

Figure 29 Statistics Screen

Exit

The Statistics screen displays the following information about the
library:

Quantum Scalar 50 User’s Guide

•

ElapsTm – seconds since boot.

•

PCycles – total number of power cycles or reboots.

•

SlotGet – count of cartridge retrievals from slots.

•

SlotPut – count of cartridge deliveries to slots.

•

SltRetG – count of retries in retrievals from slots.

•

SltRetP – count of retries in deliveries to slots.

•

DrvGet – count of cartridge retrievals from drives.

•

DrvPut – count of cartridge deliveries to drives.

•

DrvRetG – count of retries in retrievals from drives.

•

DrvRetP – count of retries in deliveries to drives.

•

DrvLdR – count of retries for cartridge loads in drives.

•

DrvUnlR – count of retries for cartridge unloads in drives.

•

XYmove – count of horizontal moves.

•

Zmove – count of vertical moves.

•

Pmove – count of extension moves.

•

Rmove – count of rotation moves.

44

Chapter 2 Basic Library Operations
OCP Components

•

XYretry – count of horizontal move retries.

•

Zretry – count of vertical move retries.

•

Pretry – count of extension move retries.

•

Rretry – count of rotation move retries.

When you are finished viewing the statistics information, press Exit
to return to the Info screen.

Operations Screen

2

The Operations (Ops) screen allows the user to view the status and issue
commands to the cabinet and tape drives.
To access the Operations screen, press Ops from the Home screen. The
OCP displays the Operations screen (see figure 30):

Figure 30 Operations Screen

Exit

The Ops screen provides the following choices:
• Library Operations
• Find Tape
• Move Tape
• Drive Operations
• Scan Inventory
Library Operations

2

To view library operations information:

Quantum Scalar 50 User’s Guide

45

Chapter 2 Basic Library Operations
OCP Components

1 From the Ops screen, use the up and down arrows to highlight
Library Operations and press Enter.
The Library Operations screen displays (see figure 31):

Figure 31 Library Operations
Screen

The following library operations options are available (see table 11):

Table 11 Library Operations
Options

Library Operations
Options
Library on/offline

Description
When the cabinet is online, the library is ready
for host communication and for backup jobs
to proceed. When the cabinet is offline, the
host is no longer able to communicate with
the library. Self tests, diagnostics, and
inventory can only be performed when the
library is offline.
Use the up and down arrows to highlight
Library on/offline and press Enter to toggle the
library online or offline. Press Yes to confirm
the command or No to cancel.

Release magazines

Use the up and down arrows to highlight

Release magazines and press Enter to view the

release magazines screen. Select the magazine
you wish to release and press Enter. Press Exit
to cancel.
Note: If there are no magazines installed or if

the magazines are configured as load ports,
this line will not display.
Quantum Scalar 50 User’s Guide

46

Chapter 2 Basic Library Operations
OCP Components

Library Operations
Options

Description

Park for shipping

Note: You must remove all tape cartridges

from the library prior to parking the library
robotics for shipment.
Use the up and down arrows to highlight Park
for shipping and press Enter to move the robot
to a safe position for transport. After the robot
is in it’s final position, the library shuts down.
After the library is shut down, you must
complete the repacking procedure before
transporting the library (see appendix D on
page 216).
2 When you are finished viewing the library operations information,
press Exit to return to the Ops screen.

2

Find Tape
To view media or tape cartridge information:
1 From the Ops screen, use the up and down arrows to highlight Find
Tape and press Enter.
The Match Label screen displays (see figure 32):

Figure 32 Match Label Screen

2 Use the up and down arrows to cycle through the alpha, numeric, or
wildcard (?) characters to enter the tape cartridge label. After each
character, press Enter.

Quantum Scalar 50 User’s Guide

47

Chapter 2 Basic Library Operations
OCP Components

If a match is found, the cartridge type and location displays.
3 If more than one match is found, a list of matching cartridges
displays. Select the tape cartridge from the list and press Enter.
The tape cartridge type and location displays.

2

Move Tape
To view the move tape screen:

1 From the Ops screen, use the up and down arrows to highlight Move
Tape and press Enter.
The Move From screen displays (see figure 33):

Figure 33 Move From Screen

To move a tape cartridge within the library:
Note:

If this is a master library in a multiple library stack, you
cannot move cartridges from one library into another. You
can only move cartridges manually from one library into
another via the remote management pages (see chapter 3
on page 63).

2 Use the up and down arrows to select a magazine, tape drive, or fixed
slot group and press Enter.
The Move from screen displays a list of storage bins within the
selected magazine, tape drive, fixed slot group, and hand/top
passthru.
3 Use the up and down arrows to select a tape cartridge from an
occupied bin and press Enter.

Quantum Scalar 50 User’s Guide

48

Chapter 2 Basic Library Operations
OCP Components

The Move to screen displays a list of magazine, tape drive, or fixed
slot groups.
4 Use the up and down arrows to select a magazine, tape drive, or fixed
slot group to receive the cartridge and press Enter.
The Move to screen displays a list of storage elements within the
selected magazine, tape drive, or fixed slot group.
5 Use the up and down arrows to select an empty bin to receive the
tape cartridge and press Enter.
The Move in progress screen displays. When the tape cartridge has
completed the move, a Success screen displays.
6 When you are finished moving tape cartridges, press Exit to return to
the Ops screen.
Drive Operations

2

To perform a drive operation:
1 From the Ops screen, use the up and down arrows to highlight Drive
Operations and press Enter.
The Drive Operations screen displays (see figure 34):

Figure 34 Drive Operations
Screen

1 Use the up and down arrows to select a tape drive and press Enter.
The following drive options are available (see table 12):
Caution:

Quantum Scalar 50 User’s Guide

Ensure that the tape drive does not contain a tape
cartridge prior to powering down the tape drive.

49

Chapter 2 Basic Library Operations
OCP Components

Table 12 Drive Options

Device Options

Description

Drive

Pwr on

This option powers on a specific tape drive
within the cabinet.

Pwr off

This option shuts down a specific tape
drive within the cabinet in preparation for
tape drive removal.

Reset

This option re initializes a specific tape
drive within the cabinet.

Drive Type

Displays the tape drive type (DLT or LTO)

Serial
Number

Displays the tape drive serial number.

Firmware
Revision

Displays the tape drive firmware revision.

2 When you are finished viewing tape drive information, press Exit to
return to the Ops screen.

2

Scan Inventory
To perform an inventory of the library:

1 From the Ops screen, use the up and down arrows to highlight Scan
Inventory and press Enter.
The Success screen displays. Press Done to complete.

Setup Screen

2

The Setup screen allows the user to view or edit various library settings
such as date and time, network and host bus information.
To access the Setup screen, press Setup from the Home screen. The OCP
displays the Setup screen (see figure 30):

Quantum Scalar 50 User’s Guide

50

Chapter 2 Basic Library Operations
OCP Components

Figure 35 Setup Screen

Enter

The Setup screen provides the following choices:
• Cabinet Setup
• Partitions Setup
• Security
• Network
• Date and Time
Cabinet Setup

2

To view the cabinet setup screen:
1 From the Setup screen, use the up and down arrows to highlight
Cabinet Setup and press Enter.
The Cabinet Setup screen displays (see figure 36):

Figure 36 Cabinet Setup
Screen

The Cabinet Setup screen displays the following options (see
table 13):

Quantum Scalar 50 User’s Guide

51

Chapter 2 Basic Library Operations
OCP Components

Table 13 Cabinet Setup

Cabinet Setup

Description

Host bus

Select the host bus option to view or edit the SCSI
IDs for the changer (library) and tape drives. The
Host bus option also allows you to set the Fibre
Channel settings for any Fibre Channel tape drives
installed. Loop ID, topology, and speed for each tape
drive can be set.
NOTE: SAS tape drives do not require a SCSI ID and
cannot be configured. Use the default tape drive
configuration information.

Stack role

Select the stack role option to view or set the library
stack role (stand alone, master, or slave).

Left load port

Select the left load port options to enable/disable the
left load port and also to designate one column or the
entire magazine as a load port.

Right load port

Select the right load port options to enable/disable
the right load port and also to designate one column
or the entire magazine as a load port.

Drive FUP
from tape

Select the magazine or fixed that contains the
firmware update cartridge (FUP) and then the
specific tape drive to update. The library must be
offline to update the tape drive firmware.

Full Inventory

When full inventory is on, the library will complete a
full inventory of the tape cartridges whenever a door
is opened. When full inventory is off and a load port
is accessed, the library will only inventory the load
port and not the entire library.

2 When you are finished viewing the cabinet setup information, press
Exit to return to the Setup screen.
Partitions Setup

2

To view or edit the partition information:

Quantum Scalar 50 User’s Guide

52

Chapter 2 Basic Library Operations
OCP Components

1 From the Setup screen, use the up and down arrows to highlight
Partitions and press Enter.
The Partitions Setup screen displays (see figure 37):

Figure 37 Partitions Setup
Screen

The Partitions Setup screen displays the following options (see
table 14):

Table 14 Partitions Setup

Quantum Scalar 50 User’s Guide

Partitions Setup

Description

Barcode swap

Select the barcode swap to change the barcode
swap option (enable/disable). When enabled, the
media type prefix is swapped from the back of
barcode to the beginning.

Emulation

Select the emulation option to change the library
emulation mode. Emulation options are: Scalar 50,
PX500, or P2000.

Auto clean

Select the auto clean option to change the library
autoclean mode (enable/disable). When enabled,
the library will automatically load a cleaning
cartridge when a tape drive requests a cleaning.

Configure Slots

The configured slots option allows you to
designate the number of slots available and
reported to the host. Use the up and down arrows
to highlight Configure Slots and press Enter. Enter
the number of configured slots and press Enter.
The library will reconfigure with the new slot
count.

53

Chapter 2 Basic Library Operations
OCP Components

2 When you are finished viewing/editing the library setup
information, press Exit to return to the Setup screen.

2

Security
To view or edit the security information:
1 From the Setup screen, use the up and down arrows to highlight
Security and press Enter.
The Security screen displays (see figure 38):

Figure 38 Security Screen

The Security screen displays the following options (see table 15):

Table 15 Security Setup

Quantum Scalar 50 User’s Guide

Security Setup

Description

Set admin PIN

The admin PIN allows access to all areas of the
OCP. Select Set admin PIN and use the up and down
arrows to cycle through the PIN numbers. Press
Enter to accept each digit and press Enter twice after
the last digit of the PIN. You must verify the PIN
number. The admin PIN can be 0 to 8 characters
long, numbers only.

54

Chapter 2 Basic Library Operations
OCP Components

Security Setup

Description

Set operator
PIN

The operator PIN only allows access to the Info or
Ops menus of the OCP. The operator cannot change
any library settings. Select Set operator PIN to set

the operator PIN. use the up and down arrows to
cycle through the PIN numbers. Press Enter to
accept each digit and press Enter twice after the last
digit of the PIN. You must verify the PIN number.
The operator PIN can be 0 to 8 characters long,
numbers only.
Note:

OCP passwords are independent of the remote
management passwords.

2 When you are finished viewing/editing the security setup
information, press Exit to return to the Setup screen.
Network

2

To view or edit the network information:
1 From the Setup screen, use the up and down arrows to highlight
Network and press Enter.
The Network screen displays (see figure 39):

Figure 39 Network Screen

Quantum Scalar 50 User’s Guide

55

Chapter 2 Basic Library Operations
OCP Components

The Network screen allows you to view or edit the following network
settings:
Note:

The network settings (IP address, subnet mask, and
default gateway) are only active when DHCP is disabled.

•

DHCP (default setting)

•

IP address

•

Subnet mask

•

Default gateway

•

Ethernet 0

2 Use the up and down arrows to select the network setting you wish
to view or edit and press Enter.
a To enable/disable DHCP, press Yes to enable DHCP or No to
disable DHCP. If your library is not connected to a network
which uses a DHCP server to assign IP information, disable this
function.
b

To set the IP address, subnet mask, and gateway, use the up and
down arrows to select the appropriate number and press Enter to
accept.

Note:

For the network information such as the IP address to be
active, the library must reboot. To reboot the library, see
“Reboot Library” on page 126.

3 When you are finished viewing/editing the network information,
press Exit to return to the Setup screen.
Date and Time

2

To view or edit the date and time information:
1 From the Setup screen, use the up and down arrows to highlight Date
and Time and press Enter.
The Date and Time screen displays (see figure 40):

Quantum Scalar 50 User’s Guide

56

Chapter 2 Basic Library Operations
OCP Components

Figure 40 Date and Time
Screen

2 Use the up and down arrows to view or edit the date and time
information. Press Enter to advance to the next choice. After you have
edited the final setting (seconds), press Save to accept the new
settings.
3 When you are finished viewing/editing the date and time
information, press Exit to return to the Setup screen.

Diags Screen

2

The Diagnostics screen allows the user to perform diagnostic tests on the
library.
To access the Diagnostics screen, press Diags from the Home screen. The
OCP displays the Diagnostics screen (see figure 41):

Figure 41 Diagnostic Screen

Enter

The Diagnostics screen provides the following choices:
• System-level Tests
• Component Tests
• Subsystem Tests

Quantum Scalar 50 User’s Guide

57

Chapter 2 Basic Library Operations
OCP Components

System-level Tests

2

To execute a system-level test:
1 From the Diags screen, use the up and down arrows to highlight
System-level Test and press Enter.
The System-level Test screen displays (see figure 42):

Figure 42 System-level Test
Screen

The System-level Test screen provides the following diagnostic tests:
•

Health test

•

Self tests

•

Calibration stats

•

Random Load/Unload

•

Random (Slots Only)

•

Random (Drive Focus)

•

Sequential bins

•

Sequential drives

2 Use the up and down arrows to select the system test and press Enter
to execute.
3 When you are finished executing system-level tests, press Exit to
return to the Diags screen.
Subsystem Tests

2

To execute a subsystem test:

Quantum Scalar 50 User’s Guide

58

Chapter 2 Basic Library Operations
OCP Components

1 From the Diags screen, use the up and down arrows to highlight
Subsystem Tests and press Enter.
The Subsystem Tests screen displays (see figure 43):

Figure 43 Subsystem Tests
Screen

The Subsystem Tests screen provides the following diagnostic tests:
•

XYZ assembly test

•

Hand assembly test

2 Use the up and down arrows to select the subsystem test and press
Enter to execute.
3 When you are finished executing subsystem tests, press Exit to return
to the Diags screen.
Component Tests

2

To execute a component test:
1 From the Diags screen, use the up and down arrows to highlight
Component Tests and press Enter.
The Component Tests screen displays (see figure 44):

Quantum Scalar 50 User’s Guide

59

Chapter 2 Basic Library Operations
Load Port Configuration

Figure 44 Component Tests
Screen

The Component test screen provides the following diagnostic tests:
•

XY test

•

Y tests

•

Rotation stats

•

Translation test

•

Camera test

•

Temperature test

•

Home position

2 Use the up and down arrows to select the component test and press
Enter to execute.
3 When you are finished executing component tests, press Exit to
return to the Diags screen.

Load Port Configuration
Load ports are used to import or export tape cartridges from the library.
When configured as a load port, your backup application will
automatically use these bins when exporting or importing tape
cartridges. The bottom left and right magazines in each library can be
configured to provide the following load port elements:
Caution:

Quantum Scalar 50 User’s Guide

When placing tape cartridges in the load port slots, ensure
that the tape cartridges are completely in the slot before
sliding the magazine back into the library.

60

Chapter 2 Basic Library Operations
Load Port Configuration

• Single column load port (5 slots SDLT/6 slots LTO)
• Magazine load port (15 slots SDLT/18 Slots LTO)
Tech Tip:

Deciding between a single column and an entire
magazines as a load port depends on the amount of tape
cartridges you typically import/export from the library. If
you generally import or export small numbers of tape
cartridges to and from the library, a single column should
be sufficient. If you import or export large numbers of
tape cartridges, an entire magazine as a load port would
be beneficial.

Each of the load ports are configured independently so that one load port
can be configured as a column and the other load port can be configured
as a column or as a magazine.
When set for a single column load port, the magazine is physically
restricted to allow access to the first column in the magazine only.
When set for a 15-slot load port, the entire magazine can be removed (the
same for a 18-slot LTO magazine).
The load port option is set using the operator control panel Setup menu.
The settings are listed in table 16 and illustrated in figure 45.

Table 16 Import/Export Option
Settings

Quantum Scalar 50 User’s Guide

Setting

Manual Access

SCSI Element

None

None

Storage element

Single column

Single column

Import/Export element

Magazine

Entire magazine

Import/Export element

61

Chapter 2 Basic Library Operations
Load Port Configuration

Figure 45 Load Port Settings

Mag 1
Single column load port

Mag 1
Full magazine load port

Enabling load ports will reduce the number of storage elements in the
library. For example, if the library is set to the default capacity (left
magazine only) and a single column is set aside as a load port, the storage
capacity is reduced by the number of slots in that first column. The
number of storage slots would be reduced by five for an SDLT magazine
and six slots in a LTO magazine.

Quantum Scalar 50 User’s Guide

62

Chapter 3

Quantum Scalar 50 Remote
Management

3

The Quantum Scalar 50 library utilizes a web-based interface which
allows you to configure and manage the library from a remote
workstation on the same network. The Quantum Scalar 50 library is
managed through the following web pages (accessible using Internet
browser software installed on the host computer):
• Status allows you to view the following: hardware status, event logs,
and statistics
• Operations allows you to perform cabinet operations remotely such
as cartridge movement and inventory requests and drive operations
• Setup allows you to setup cabinet identification, user information,
SCSI IDs, network information, events, date and time information,
partitioning, secure tape, and tape encryption information.
• Utilities allows the user to run cabinet utilities remotely.
• Reference links to related sites.
• Logout allows the user to log out of the library remote management
pages.

Quantum Scalar 50 User’s Guide

63

Chapter 3 Quantum Scalar 50 Remote Management
Quantum Scalar 50 Web Pages

Quantum Scalar 50 Web Pages
The internet browser software is not supplied with the Quantum Scalar
50 library; you must obtain and install it independently. The Quantum
Scalar 50 library supports the following internet browsers:
• Microsoft Internet Explorer 6.1 or later
You can download this software from
http://www.microsoft.com.
Note:

To optimize performance, all browsers should have both
cookies and pop-ups enabled. This allows the refresh activities
of the remote management web pages to work appropriately.
Java 1.4.2 or above available from http://www.java.com
should also be installed to support applets that automatically
refresh pages and display pop-ups for warnings and critical
events.

• Mozilla Suite 1.7 on Solaris 10
You can download this software from
http://www.mozilla.org
• Firefox 1.0.6 on Windows
You can download this software from
http://www.mozilla.org
• Java Plug-in 1.4.2 or later
You can download this software from
http://www.java.com

Quantum Scalar Web
Page Menu Items

3

The following figures depict the menu items available from the Quantum
Scalar 50 Web Pages:
• Figure 46 provides the default menus for the Scalar 50 web pages
• Figure 47 provides an additional menu for the tape security feature
available with the DLT-S4 tape drives. When this feature is enabled,
the menu will display as part of the Setup page.

Quantum Scalar 50 User’s Guide

64

Chapter 3 Quantum Scalar 50 Remote Management
Quantum Scalar 50 Web Pages

Figure 46 Quantum Scalar 50
Web Page Menu Items

Status

Operations

Overview

Identification

Find

Date and Time

Setup

Find Barcode

Library Information

Setup Cont.
Events
Email

Model number

Find Media

Model

Software Version

Logical Map

Serial Number

Physical Map

Library Name

Warning

Contract Number

Informational

Hardware Status

Move

Cabinet

Source

Serial number

Partition

SCB temp.

Element

BackPlane status

Position

BackPlane temp.

Destination

System power...

Partition

SCB volt. (1.2v)
SCB volt. (1.8v)
SCB volt. (2.5v)
SCB volt. (3.3v)
SCB volt. (5.0v)
cPCI card (12v)

Fan sp. (RPM)
OCP
OCP status

Drive #

Address

Remove Users

Drives

Partition
Action

Full Name

Fax

Reset

Pager
Email
Add to Event List

Physical Map
SCSI/Fibre
Cabinet
Device

# slot/port gets

SCSI ID

# slot/port puts

LUN

# slot/port get retries

Vendor

# slot/port put retries

Model

# drive gets

Serial Number

From: date/time

# drive puts

Revision

To: date/time

# drive get retries

Connectivity

Hard errors
Soft errors
Update errors
Boot errors

Network Infor.
# XY motor moves
# Z motor moves
# picker moves
# rot. motor moves

Cabinet
Cabinet #

Network

# drive load retries
# drive unload retries

# XY motor retries
# Z motor retries
# picker retries
# rot. motor retries

Quantum Scalar 50 User’s Guide

Email server Infor.

Load ports (L/R)
Partitions
Partition List
Remove All
Partition Config.

# of power cycles

All errors

IEEE ID

Runs

MAC Address

Continuous

Slots

Start Test

Load Ports

Health Tests

State

Category

Cabinet

Sub-Sys. Tests

Library

Hostname

From:

Domain

Email server

IP Address

Primary DNS

Default Mask

Secondary DNS

Obtain DHCP

Name
Cabinets

Comp. Tests
Maintenance
Conf. Files
Action
Cabinet
Browse
Upload Firmware
Browse
Upload Drive Image

Drive Type

Drives

Drive Number

Load Ports

Cabinet

Partion Options
En. Auto Cln.
Em. P-Series
Em.Scalar 50
En. Bar. Swap
Configured Slots

Drives

Sys. Level Tests

Magazines

Surrogate Drive

Default Gateway
Cabinet Information
Cabinet

Auto adjust.

Library Config.

IEEE ID
MAC Address

Serial Number

Time zone

Address

Serial Number

Action

Current time

Administrator

Model
Software Version

Partition

Assign Role

Drive fan RPM

# drive put retries

Test Type

Lib. Level Tests

Operator

Library Information

IP Address

Previous Results

Drive serial #

View Events

Informational

Links

Subnet Mask

System Tests

Logout

About

Start Test

Time

Power on time

Event Log

Warning

Reference

Select Cabinet

Date

Drive present

Drive Activity

Critical

Health Test

User Name

Phone

Cabinet #

Event Types

System Tests

Password

Pwr Off

Logical Map

Trap Dest.

Partition
Fib. Bridge Rescan

Verify password

Pwr On

Library Statistics

SNMP
Comm. Names

Reboot Library
Park for Shipping

Date and Time

Drive Power

Drive #

Send test

Library
Online/Offline

User Name

Drive Reg. tmp

OCP temp.
Drives

Company

User Information

Drive Operations

Drive Status

Business Inform.

Physical Map

Logical Map

Pwr sply (24v)

E-mail

Users List

Physical Map

Pwr sply pres.

Position

Position

Left mag. door

Power Supply

Recipients
Non-recipients

Logical Map

Right mag. door

Power Supply #

Location

Users

Partition

Critical

Description

Element

Inventory

Doors

Message Type

Utilities

Browse
Logs
Drive Log
View Log
FA Log
Cabinet
Retrieve

Field Service
Setup Wizard

Tasks

Library Offline
Date and Time
Configuring Devices
Configuring Load Ports
Configuring Partition
Setup Wizard Complete

65

Chapter 3 Quantum Scalar 50 Remote Management
Quantum Scalar 50 Web Pages

Figure 47 Quantum Tape
Security and Tape Encryption
Menus

Setup
Secure Key
Protection Mode
Never write...
Only write...
Write to all...
Enable/Disable...
Enable all drives
Disable all drives
Select drives
Select Secure Key
Sec. Key Name
Date Created
Assign Secure Key
Find Sec. Cart.
Barcode
Sec. Name, Date
Create Secure Key
Sec. Key Name
Secure Key
Verify Sec. Key
Delete Secure Key
Unused Keys
Inactive Keys
Active Keys
Backup Secure Key
Encryption Key
Verify Encr. Key
Upload Secure Key
Encryption Key
File Name

Quantum Scalar 50 User’s Guide

66

Chapter 3 Quantum Scalar 50 Remote Management
Quantum Scalar 50 Web Pages

Accessing Scalar 50 Web
Pages

3

To access the Quantum Scalar 50 web pages:
1 On the host computer, open the internet browser software.
2 In the Address field, type http://IPaddress/ where IP address is the IP
address for the Quantum Scalar 50. (see “Setup” on page 84).
3 Enter the username and password and click OK.
Note:

The default username and password is admin.

The Overview page displays (see figure 48):

Figure 48 Overview Page

Banner area
Quick status
Navigation area
Content area

Using the Quantum Scalar
50 Web Pages
3

Quantum Scalar 50 User’s Guide

The first page that displays when you access the Quantum Scalar 50 web
pages is the Quantum Scalar 50 Overview page (see figure 48). This page
includes information on the Quantum Scalar 50 such as library name,
date and time, and includes a dynamic graphic which changes colors
depending on the library health.

67

Chapter 3 Quantum Scalar 50 Remote Management
Quantum Scalar 50 Web Pages

The Overview page is divided into five distinct sections:
• Banner
• Quick status
• Navigation area
• Content area
The banner frame displays the corporate logo and product name. The
contents frame displays a list of the Quantum Scalar 50 web pages. To
view a page, click its corresponding link. The management frame
displays the page you selected.
To return to a previous web page, click the browser’s Back button.

Quick Status

3

Table 17 Quick Status Library
Health Conditions

The Quick Status icon provides the current health status for the library.
Refer to the following tables (table 17 and table 18) for quick status library
health conditions.
Quick Status Icon

Library Health

Description

Library health:
OK.

The library health is
OK.

Library health:

The library health is
in a Critical state
(needs attention)

Critical

Table 18 Quick Status Health
Messages

Quantum Scalar 50 User’s Guide

Quick Status Messages

Description

Online and Offline

These messages indicate the
current availability status of the
library.

Init Error

The library has failed to initialize.
Review the hardware status page
and contact Quantum Customer
Support if necessary.

68

Chapter 3 Quantum Scalar 50 Remote Management
Quantum Scalar 50 Web Pages

Quantum Scalar 50 User’s Guide

Quick Status Messages

Description

Stopped

The hand has stopped. Check the
error log and contact Quantum
Customer Support if necessary.

Door Open

A library door is open.

Tape Cleaning

A tape drive is being cleaned.

Moving

A tape cartridge is being moved.

Code Update

The library is in the process of
upgrading the system code. Wait
until the process is complete

Initializing

The library is in the process of
coming online. Wait until the
library becomes online.

Power Down

The library is powering down.
Wait for the unit to shutdown.

Communication Down

The library is in the process of
shutting down. Library
communication will resume
when the library powers on.

Over Temp

The library has exceeded the
maximum temperature threshold.
Review the hardware status page
and contact Quantum Customer
Support if necessary.

Diagnostic

The library is executing a
diagnostic test. Wait for the test to
complete.

69

Chapter 3 Quantum Scalar 50 Remote Management
Status

Status
The Status page displays the general status or health of the library as well
as specific hardware status. The page also provides access to event logs as
well as library statistics.
The Status page is divided into the following sections:
• Overview Page
• Hardware Status Page
• Event Log Page
• Statistics Page

Overview Page

3

To access the Overview page, from any page, click Status from the
navigation bar.
The management frame displays the Status page (see figure 49).

Figure 49 Status Page

Quantum Scalar 50 User’s Guide

70

Chapter 3 Quantum Scalar 50 Remote Management
Status

Hardware Status Page

3

The Hardware status page displays the library component status within
the library.
To access the Hardware page, from the Status page, click on the Hardware
tab at the top of the page.
The Hardware Status page displays (see figure 50):

Figure 50 Hardware Status
Page

Hardware
components

Library components within the library are displayed in a tree-like
fashion. A red background indicates critical or failed condition. Related
values or error messages are listed under details.
To view the status of a library component
1 Click on a plus sign to expand a branch and display the status of
related subcomponents. Click on a minus sign to collapse a branch.
Click Expand All/Collapse All to expand or collapse all branches.
Some components, such as drives, are displayed as a link. Clicking on
the link will open a detail window displaying all data related to the
component.

Quantum Scalar 50 User’s Guide

71

Chapter 3 Quantum Scalar 50 Remote Management
Status

Event Log Page

3

The Event Log page allows the user to view events that occur on the
library. These events are divided into the following categories:
• All - views all events in all categories
• Hard - views only hardware related events
• Soft - views only software related events
• Update - views only events related to library update functions
• Boot - views only events related to library boot sequence
To access the Event Log page, from the Status page, click on the Event Log
tab at the top of the page.
The Event Log page displays (see figure 51):

Figure 51 Event Log Page

Quantum Scalar 50 User’s Guide

72

Chapter 3 Quantum Scalar 50 Remote Management
Status

To view an Event Log:
1 In the Event Log page, change the From and To areas to reflect the
time range of the event log you wish to view. Click the up and down
arrows to change the hour and/or minute values by increments of
one. Double-clicking will increment or decrement the value by 5. You
may also type in a valid hour (0 - 24) or minute (0 - 59).
Note:

The default date/time range is one hour prior to the
current time and day.

2 Select desired categories and priority levels (critical, warning, or
informational) for the event list.
3 Click View to display the list.
Note:

Search time will vary depending on the time range
entered.

A smaller window displays the information matching the range,
category, and priority specified.

Statistics Page

3

The Statistics page allows the user to view library statistics for the entire
library or certain components within the library.
The following table shows the statistics available from the Statistics page:

Quantum Scalar 50 User’s Guide

73

Chapter 3 Quantum Scalar 50 Remote Management
Status

Table 19 Statistics Information

Cabinet or Component

Statistical Information

Cabinet (library)

Time since last power-on (seconds)
Time processing robot commands
(seconds)
Estimated number of power cycles
Attempted slot/port picks
Attempted slot/port places
Attempted drive picks
Attempted drive places
Number of individual horizontal moves
Number of individual vertical moves
Number of individual extension moves
Number of individual hand moves
Number of individual depth moves
Number of individual rotary moves
Number of horizontal retries
Number of vertical retries

Quantum Scalar 50 User’s Guide

74

Chapter 3 Quantum Scalar 50 Remote Management
Status

Cabinet or Component

Statistical Information
Number of extension retries
Number of hand retries
Number of depth retries
Number of rotary retries
Number of drive place retries
Number of drive pick retries
Number of partially gripped cartridge
retries
Number of drive load retries
Number of barcode scan retries
Number of slot/port pick retries
Number of slot/port place retries

To access the Statistics page, from the Status page, click on the Statistics
tab at the top of the page.
The Statistics page displays (see figure 52):

Quantum Scalar 50 User’s Guide

75

Chapter 3 Quantum Scalar 50 Remote Management
Status

Figure 52 Statistics Page

Note:

Quantum Scalar 50 User’s Guide

Statistics for individual elements (a specific drive, slot, or port) are
included in the element detail window and can be viewed by
clicking on a drive, slot, or port link from zoom windows accessed
via the Operations pages. The zoom windows are opened by
clicking on the panel or cluster name from physical or logical
maps.

76

Chapter 3 Quantum Scalar 50 Remote Management
Operations

Operations
The Operations page is divided into the following sections:
• Find Page
• Move Page
• Inventory Page
• Drives Page

Accessing the
Operations Page

3

To access the Operations page, click Operations from the contents frame.
The management frame displays the Operations page (see figure 53).

Figure 53 Operations Page

Quantum Scalar 50 User’s Guide

77

Chapter 3 Quantum Scalar 50 Remote Management
Operations

Find Page

3

The Find page allows the user to find and locate specific barcodes within
the library as well as view the library contents (slots, ports, drives, hand,
or address).
To access the Find page, from the Operations page, click on the Find tab at
the top of the page.
The Find page displays (see figure 54):

Figure 54 Find Page

Find barcode

Find Media ID

Select physical/logical
map

The Find page is divided into the following sections:
• Find Barcode
• Find Media ID
• Select Map

Quantum Scalar 50 User’s Guide

78

Chapter 3 Quantum Scalar 50 Remote Management
Operations

3

Find Barcode
The find barcode section allows the user to find a specific barcode (or
partial barcode) within the library and view its location.
To find a barcode or partial barcode:

1 Enter a barcode, or partial barcode with wildcards (*,?) in the barcode
field.
Note:

Leaving the barcode field empty will result in listing all
barcode labels within the library.

2 Click Find.
A separate window displays the barcode(s) sharing the barcode
string entered in the barcode field. Click the individual barcode label
to display the corresponding cartridge detail page.

3

Find Media ID
The show contents section allows the user to locate a specific media ID
within the library (slots, ports, drives, hand, or address)
To find a media ID:
1 Enter a media ID, or partial ID with wildcards (*, ?) in the Media ID
field.
Note:

Leaving the media ID field empty will result in listing all
barcode labels within the library.

2 Click Find.
A separate window displays the media ID(s) sharing the string
entered in the media ID field. Click the individual barcode label to
display the corresponding cartridge detail page.

Quantum Scalar 50 User’s Guide

79

Chapter 3 Quantum Scalar 50 Remote Management
Operations

3

Select Map
The select map section allows the user to view the library in either a
physical or logical view. To toggle between physical and logical map,
click the Physical/Logical Map button in the map section.
Note:

The Physical/Logical Map information is displayed at the
bottom of each Operations page.

Physical Map: A physical view displays a high level physical
representation of the library. Slots, magazines, drives, and fixed slots are
displayed as a panel located on either the left, rear, or right wall of the
library. Clicking on the panel name opens a zoom view of the panel (i.e.
similar to pulling out a loadport or drawer) displaying all elements (slots,
ports, or drives) in a spreadsheet format.

Note:

The physical map may show gaps in the element numbering
depending on the load port configuration.

Logical Map: A logical map displays slots, magazines, drives, and fixed
slots. Clicking on the panel name opens a zoom view of the panel (i.e.
similar to pulling out a loadport or drawer) displaying all elements (slots,
ports, or drives) in a spreadsheet format. From the zoom view, clicking
on an element opens a detail window.

Note:

Move Page

3

Under the Logical Map view, an option to print the view to a
local printer is available by clicking on the Print View link
located in the upper left-hand corner of the Logical Map
section.

The Move page allows the user to move a single cartridge from a source
(slot, port, drive, or address) to a destination (slot, port, drive, or
address).
Note:

The library must be off-line to move a cartridge.

To access the Move page, from the Operations page, click on the Move tab
at the top of the page.
The Move page displays (see figure 55):

Quantum Scalar 50 User’s Guide

80

Chapter 3 Quantum Scalar 50 Remote Management
Operations

Figure 55 Move Page

Move cartridge
Source

Destination

To move a cartridge:
1 Select a cabinet, source element (slot, drive, address, or hand), and
enter a starting position and count. If the count field is left empty,
only the starting cartridge is moved.
Note:

The hand is the robotic gripper used to move
cartridges in the library. If the library is in a
stacked environment with other Scalar 50
libraries, the pass-thru slot is available as a source
element.

2 Select a destination cabinet, element, and position. If more than one
cartridge is moved, the position entered in as a destination is the first
one filled, consecutive elements must be empty.

Quantum Scalar 50 User’s Guide

81

Chapter 3 Quantum Scalar 50 Remote Management
Operations

Inventory Page 3

The Inventory page allows the user to perform an inventory on all
elements within the library or specific element ranges.
Note:

The library must be off-line to perform an inventory.

To access the Inventory page, from the Operations page, click on
the Inventory tab at the top of the page.
The Inventory page displays (see figure 56):

Figure 56 Inventory
Page

Inventory

To perform an inventory:
1 Select the cabinet or library to inventory.
2 Click Apply to perform the inventory.
The progress of the inventory displays in a separate window.

Quantum Scalar 50 User’s Guide

82

Chapter 3 Quantum Scalar 50 Remote Management
Operations

3

Drives Page

The Drives page allows the user to perform the following actions on the
tape drives within the library:
• Reset - re initializes the tape drive
• Power off - shuts down the tape drive
• Power on - powers on the tape drive
To access the Drives page, from the Operations page, click on the Drives
tab at the top of the page.
The Drives page displays (see figure 57):

Figure 57 Drives Page

Drive operations

Quantum Scalar 50 User’s Guide

83

Chapter 3 Quantum Scalar 50 Remote Management
Setup

To perform an action on a tape drive(s)
1 Select a cabinet and enter a tape drive number
2 Select the action to perform (power off, power on, or reset).
Caution:

Note:

Ensure that the tape drive does not contain a tape
cartridge prior to powering down the tape drive.

If you power a tape drive off from the Drives page and
then power the tape drive back on, the tape drive must
then be reset to be operational. The complete process from
the Drives page is, power the tape drive off, power the tape
drive on, reset the tape drive.

3 Click Apply to perform the action.
The drive actions are performed.

Setup
The Setup page is divided into the following sections:
• Identification
• Users
• Key Users
• SCSI/Fibre
• iSCSI Bridge - Only if a Fibre Channel or iSCSI bridge is present
• Network
• Events
• Date & Time
• Library
• Partitions
• Field Service

Quantum Scalar 50 User’s Guide

84

Chapter 3 Quantum Scalar 50 Remote Management
Setup

• Setup Wizard
• Secure Key
Note:

The Secure Key tab is only available under the Setup page
when the secure key administrator (skadmin) is logged onto
the system AND a secure key capable tape drive (DLT-S4) is
installed in the library.

• Secure Key Best Practices and Tape Migration

Accessing the Setup
Page

3

To access the Setup page, click Setup from the contents frame.
The management frame displays the Setup page (see figure 58).

Figure 58 Setup Page

Quantum Scalar 50 User’s Guide

85

Chapter 3 Quantum Scalar 50 Remote Management
Setup

Identification

3

The identification information is used to identify the library to assist
customer support when servicing the library.
1 To access the Identification page, from the Setup page, click on the
Identification tab at the top of the page.
The Identification page displays (see figure 58).
2 Edit the identification information as desired (see table 20 for a
description of the fields).
3 Click Save when complete.

Table 20 Identification
Information

Quantum Scalar 50 User’s Guide

Field

Description

Model

Display only. Not entered by user

Serial Number

Display only. Not entered by user

Library Name*

Enter a name to identify this specific library

Contract
Number*

Enter the contract number for the library. This is
used to identify the library to customer support.

Asset Number

Customer internal tracking number.

Location

Enter the location of the library. This helps to
identify the library when remotely controlling
multiple machines.

Description

Enter a short description of the library.

Company*

Enter the company name where the library is
located

Address*

Enter the company address where the library is
located

*

Indicates a required field.

86

Chapter 3 Quantum Scalar 50 Remote Management
Setup

Users

3

This section allows users to be added to the library configuration. The
user access is also controlled from this section as well as email
notification.
1 To access the Users page, from the Setup page, click on the Users tab
at the top of the page.
The Users page displays (see figure 59).

Figure 59 Users Page

2 Edit the user information as desired (see table 21 for a description of
the fields).
Note:

The username and password are limited to 7 characters.

3 Click Apply when complete.
4 To remove a user, select the user check box and click Remove User.

Quantum Scalar 50 User’s Guide

87

Chapter 3 Quantum Scalar 50 Remote Management
Setup

Table 21 User Information

Field

Description

Full Name*

Enter the full name of the user

User Name*

Enter a user name. The user name can be no
more than seven characters.

Key Users

3

Password/Verify
Password*

Enter a password. The password can be no more

Assign Role

Select either Administrator or Operator for user
privileges. An operator only has access to
library status information. An administrator has
access to all areas of the remote management
pages.

Address*

Enter an address for the user’s location

Phone

Enter the users phone number

Fax

Enter the users fax number

Pager

Enter the users pager number

E-mail*

Enter the users email address

Add to Events Email List

Adds this user to the email events list.

*

Indicates a required field.

than seven characters.

The Key User is the only user that has the ability to create, modify, and
delete a Secure Key for the library. The Key User also has the ability to
enable and disable Secure Capable Drives for reading and writing data to
and from tapes using the Secure Keys.
Creating a Key User

3

When a user is created with administrator privileges (other than the
default admin user), the Create Key User section appears at the bottom of
the Users page (see figure 60).

Quantum Scalar 50 User’s Guide

88

Chapter 3 Quantum Scalar 50 Remote Management
Setup

Figure 60 Create Key User

To create a Key User:
Note:

Only users with administrator privileges (other than the
default administrator) can create a secure user.

There is only one Key User and the username is always skadmin.
1 Enter a secure password.
Note:

Key User Passwords must be at least four characters long
and include at least one non-alphanumeric character.
Spaces, double quotes (“), and blank passwords are
rejected. Key User Password and Verify Password must
match.

2 Verify the secure password by entering the password a second time
in the Verify Password box.
3 Click Create to create the Key User.
The Key User is created.

3

Remove Key User
Once the Key User is added, the Remove Secure User section displays at
the bottom of the Users page (see figure 61).

Figure 61 Remove Secure
User

To remove the Key User, click Remove.
Quantum Scalar 50 User’s Guide

89

Chapter 3 Quantum Scalar 50 Remote Management
Setup

The Key User is removed.
Updating the Key User Password

3

To update the secure key password:
Note:

Only the Key User (logged in as skadmin) can change the key
user password.

1 Log on to the library as the Key User (username: skadmin).
2 Enter the current Key User Password.
3 Click the Users tab.
The Change Key User Password section displays at the bottom of the
Users page (see figure 62).

Figure 62 Change Key User
Password

4 Enter a new Key User Password.
Note:

Key User Passwords must be alphanumeric strings of at
least one character. A blank secure password will be
rejected. Key User Password and Verify Password must
match.

5 Verify the Key User Password by entering the password a second
time in the Verify Password box.
6 Click Update to update the Key User Password.
The Key User Password is updated.

Quantum Scalar 50 User’s Guide

90

Chapter 3 Quantum Scalar 50 Remote Management
Setup

SCSI/Fibre

3

This section allows the user to set the SCSI IDs for the changer (library)
and every tape drive within the library and also configure any Fibre
Channel tape drives.
Note:

You can also determine the tape drive firmware revision from
the SCSI/Fibre page.

Note:

SAS tape drives do not require a SCSI ID and cannot be
configured. Use the default tape drive configuration
information.

1 To access the SCSI/Fibre page, from the Setup page, click on the SCSI/
Fibre tab at the top of the page.
The SCSI/Fibre page displays (see figure 63).

Figure 63 SCSI Page

2 To change a SCSI ID, enter the ID number in the field next to the
device and click Apply.

Quantum Scalar 50 User’s Guide

91

Chapter 3 Quantum Scalar 50 Remote Management
Setup

To change a drive SCSI ID, the cabinet must be off-line.
Note:

Changing SCSI IDs or Fibre Channel topology may affect
the operation of your library with other systems. Library
must be rebooted before a new changer SCSI ID or Fibre
Channel configuration will take effect.

3 Click the device (tape drives) to view the drive details.

3

Native Fibre Channel Tape Drives
To configure the Native Fibre channel topology, speed, and loop ID:
1 Click on the Fibre link under the Connectivity type.

The media changer or tape drive configuration screen displays. Refer
to table 22 for configuration options.

Table 22 Native Fibre Channel
Configuration Options

iSCSI Bridge

3

Configuration Option

Description

Configured Speed

Select 1 G, 2 G, 4G, or Auto
Negotiate to set the configured
speed

Configured Topology

Select point-to-point, arbitrated
loop, or Auto negotiate to set the
configured topology.

Loop ID

Select the loop ID. The loop ID
can only be set when the
configured topology is set to
arbitrated loop.

This section allows users manage the TC2201 iSCSI bridges installed in
the cabinet.
Note:

Quantum Scalar 50 User’s Guide

The iSCSI bridge information only displays when a iSCSI
bridge is installed in the library.

92

Chapter 3 Quantum Scalar 50 Remote Management
Setup

1 To access the iSCSI Bridge page, from the Setup page, click on the
iSCSI Bridge tab at the top of the page.
The iSCSI Bridge page displays (see figure 64).

Figure 64 iSCSI Page

Bridge links

The iSCSI bridge page displays:
•

Cabinet number(s)

•

Device number(s)

•

IP address for the iSCSI bridge

•

Model of the iSCSI bridge

•

World wide name for the iSCSI bridge

•

Serial number for the iSCSI bridge

•

Current firmware revision on the iSCSI bridge

2 Click Rescan to discover new iSCSI bridges or updated firmware.
3 Click on the iSCSI bridge you want to manage.
The TC2201 web interface displays. For more information on the
TC2201 iSCSI bridge and the web interface, see the Quantum TC2201
User’s Guide (PN 81-81539) included on the Quantum Scalar 50
documentation CD.

Network

3

Quantum Scalar 50 User’s Guide

The network information section allows the user to enter network
information so the library can be controlled remotely via an Ethernet
network.
93

Chapter 3 Quantum Scalar 50 Remote Management
Setup

1 To access the Network page, from the Setup page, click on the Network
tab at the top of the page.
The Network page displays (see figure 65).

Figure 65 Network Page

2 Edit the network information as desired (see table 23 for a description
of the fields).
3 Click Save.
The Quantum Scalar 50 will not use the new network information
until it has been rebooted (see “Setup” on page 84).

Quantum Scalar 50 User’s Guide

94

Chapter 3 Quantum Scalar 50 Remote Management
Setup

Table 23 Network
Configuration Fields

Events

3

Field

Description

Hostname*

View or set the hostname for the library (for
example, the DNS name)

Domain*

View or set the domain name for the library

IP Address*

View or set the IP address for the library

Subnet Mask*

View or set the subnet mask for the library

Default Gateway*

View or set the default gateway for the library

Obtain IP from
DHCP Server

If your network uses a DHCP server to assign
device IP addresses dynamically, select this box

Email Server

View or set the email server information

Primary DNS
Address

View or set the primary DNS address

Secondary DNS
Address

View or set the secondary DNS address

*

Indicates a required field.

The Events page allows the user to designate what library events are
emailed to users as well as setup SNMP traps.
Note:

For a complete list of available library events, see chapter 4 on
page 137.

1 To access the Events page, from the Setup page, click on the Events
tab at the top of the page.
The Events page displays (see figure 66).

Quantum Scalar 50 User’s Guide

95

Chapter 3 Quantum Scalar 50 Remote Management
Setup

Figure 66 Events Page

2 Edit the Email information as desired (see table 24 for a description of
the fields) and click Update.
3 After editing the Email information, click the Send button to test the
notification system. If the test is not successful, verify the email server
information and the administrative recipients list and try again.
The Email area details are shown in table 24, table 25, and table 25.

Quantum Scalar 50 User’s Guide

96

Chapter 3 Quantum Scalar 50 Remote Management
Setup

Table 24 Email Notification

Table 25 Send Email Test

Quantum Scalar 50 User’s Guide

Field

Description

Message Type:
Critical

When a hardware failure occurs on the Quantum
Scalar 50 system such as a transition to a
degraded, limited access, or failed system state,
an email is sent to everyone on the critical failure
recipient list.

Message Type:
Warning

When a warning state exists on the Quantum
Scalar 50 system such as an overtemp condition,
an email is sent to everyone on the warning
recipient list.

Message Type:
Informational

When an informational event has occurred on the
Quantum Scalar 50 system such as starting up or
shutting down the system, an email is sent to
everyone on the operator access recipient list.

New

To add a new recipient to a specific list, type the
email address of the new recipient in the field
and click Save.

Edit

To edit a recipient, select the individual email
address from the list and click Edit.

Remove

To remove an email notification type from the Email list, select the E-mail type and click Remove.

Field

Description

Send Test

To test the email notification system, click Send
Test. An email is sent to the critical
e-mail
recipients list. If the test email is not successful,
verify the email server information and the
critical recipients list and try again.

97

Chapter 3 Quantum Scalar 50 Remote Management
Setup

3

SNMP

If the customer wishes to use the Quantum Scalar 50 system with a
network framework application such as HP OpenView, or CA Unicenter,
the SNMP configuration must be defined. SNMP stands for Simple
Network Management Protocol, a set of protocols for managing complex
networks. SNMP works by sending messages, called protocol data units
(PDUs), to different parts of a network. SNMP-compliant devices, called
agents, store data about themselves in Management Information Bases
(MIBs) and return this data to the SNMP requesters.
1 Under Community Names (see figure 67), click New to enter the new
community information:
a A unique name in the Name field, the field holds up to 60
characters. No blank spaces are allowed.
b

IP address in the IP Address field, if the value in the Network
Mask edit box ends in a zero, the value in the IP address edit box
must also end in a zero

c

Subnet mask in the Network Mask field.

d

Access rights for the new community:
•

Read Only allows SNMP read operations:

•

Read/Write allows both SNMP read and write operations.

2 Click Save.
A Results page displays indicating the community has been added.
3 Click New in the Trap Destination area (see figure 67), to set the IP
addresses that are to receive the traps generated by the Quantum
Scalar 50, for example, 12.34.56.78.

Quantum Scalar 50 User’s Guide

98

Chapter 3 Quantum Scalar 50 Remote Management
Setup

Figure 67 SNMP Section of
Event Page

4 Enable the trap selections to be reported (see table 26):

Table 26 SNMP Trap
Selections

Field

Description

Informational

If selected, Informational Traps are enabled.

Warning

If selected, Warning Traps are enabled.

Critical

If selected, Critical Traps are enabled.

5 Click Save.
A Results page displays indicating the configuration has been
changed.

Date & Time

3

The date and time page allows the user to view and set the date and time
on the library. This allows the library to time stamp any events that occur.
Note:

Quantum Scalar 50 User’s Guide

The Quantum Scalar 50 must be offline to adjust the time and
date.
99

Chapter 3 Quantum Scalar 50 Remote Management
Setup

1 To access the Date & Time page, from the Setup page, click on the Date
& Time tab at the top of the page.
The Date & Time page displays (see figure 68).

Figure 68 Date & Time Page

2 Select Manual to manually set the system date and time using the
Change button for the system date and drop down boxes for the
system time.
3 Click Save when complete.
The Quantum Scalar 50 will not use the new date and time zone
information until it has been rebooted.

Quantum Scalar 50 User’s Guide

100

Chapter 3 Quantum Scalar 50 Remote Management
Setup

Library

3

The library configuration section allows the user to configure automatic
library settings.
Note:

The library must be offline to change the library settings.

1 To access the Library page, from the Setup page, click on the Library
tab at the top of the page.
The Library page displays (see figure 69).

Figure 69 Library Page

2 Edit the Library Configuration settings as desired (see table 27 for a
description of the fields) and click Apply.

Table 27 Library Configuration

Field

Description

Enable Left Load
Port/Right Load
Port

When enabled, the Left Load Port/Right Load
Port will act as load ports. When disabled, they
will be use as regular slots.

3 Click Reset to return the library to its original settings.

Quantum Scalar 50 User’s Guide

101

Chapter 3 Quantum Scalar 50 Remote Management
Setup

4 Enter the Capacity Key (see table 28 for a description of the fields) and
click Apply.
Note:

Table 28 Capacity on Demand
Configuration

Capacity on demand cannot be used in a partitioned
library.

Field

Description

Maximum
Licensable Slots

Displays the maximum number of slots that can
be licensed in the library.

Current Licensed
Slots

Displays the current number of slots licensed in
the library.
• 22 SDLT/26 LTO slots = Level 1 or default
library capacity
• 32 SDLT/38 LTO slots = Level 2 or full library
capacity

Current Capacity
Key

Displays the current capacity key for the library.

Capacity Key

To enable all of the available slots in the library
(Level 1 to Level 2 capacity), enter the new
capacity key for the library.

Caution:

Changes to the number of licensed slots takes effect
immediatly.

5 Click Reset to return the library to its original settings.

Partitions

3

Quantum Scalar 50 User’s Guide

Library partitioning provides the capability to divide the library’s storage
elements into separate partitions, usable by separate host computers on
the same network. The maximum number of partitions per library is four
partitions; however, the number of partitions is limited by the number of

102

Chapter 3 Quantum Scalar 50 Remote Management
Setup

installed tape drives. For example: in a Scalar 50 with two tape drives
installed, only two partitions would be possible in this library.
Note:

Partitioning cannot be used unless all libraries are at FULL
capacity. See “Library” on page 125 for more capacity key
information.

Partitioning Requirements

3

Only a Scalar 50 library with a Native Fibre Channel interface can support
partitioning. You must also have a Fibre Channel switch available to
connect to the library Fibre Channel SCB, Fibre Channel hosts, and native
Fibre Channel tape drives. If you do not have a Fibre Channel switch
available, the library is limited to one partition (see figure 70).

Figure 70 Native Fibre
Channel Partition Example

In the example shown in figure 70, you must zone the Fibre Channel
switch as follows:
• Partition #1: Zone 1 must have the media changer (port 1), tape drive
1 (port 2) and host 1 (port 4).
Quantum Scalar 50 User’s Guide

103

Chapter 3 Quantum Scalar 50 Remote Management
Setup

• Partition #2: Zone 2 must have the media changer (port 1), tape drive
2 (port 2) and host 2 (port 5).
Zoning the Fibre Channel switch as described above will allow the host to
view only the tape drive for it’s specific partition. The media changer is
visible to both partitions and hosts.

3

Scalar 50 Configurations that do NOT Support Partitioning
The following Scalar 50 configurations do NOT support partitioning:

• Scalar 50 Libraries Containing SAS Tape Drives - a library containing a
HP LTO-4 Half Height tape drive cannot be partitioned.
• Native Parallel SCSI interface - a parallel SCSI library cannot support
partitioning.
• iSCSI bridged Parallel SCSI - a parallel library with a TC2201 iSCSI
bridge cannot support partitioning.
• Native Fibre Channel without a switch - a Native Fibre Channel library
that does not have a Fibre Channel switch cannot support
partitioning.
• Scalar 50 with Level 1 Capacity - A default capacity library with only
four magazine columns available cannot be partitioned. You must
have FULL capacity to partition the library.
Accessing the Partitions Page

3

To access the Partitions page, click Partitions from the Setup page.
The management frame displays the Partitions page (see figure 71).

Quantum Scalar 50 User’s Guide

104

Chapter 3 Quantum Scalar 50 Remote Management
Setup

Figure 71 Partitions Page

The Partitions page contains a list of all user defined partitions and a
section for either creating a partition or changing a partition's
configuration and options.
Clicking on a partition name in the Partition list displays a detail
window listing all details for the selected partition.

3

Creating a Library Partition
To create a library partition:
Note:

The library must be offline to create or edit a library partition.

1 Enter the partition information listed in table 29 and click New to
create the partition.

Quantum Scalar 50 User’s Guide

105

Chapter 3 Quantum Scalar 50 Remote Management
Setup

Table 29 Creating a Partition

Quantum Scalar 50 User’s Guide

Field

Description

Partition Name

Enter a unique name for the partition. Partition
names must start with a letter (a-z or A-Z), cannot
be longer than 10 characters, and cannot contain
spaces or special characters. Library, Global, and
Unassigned are reserved and cannot be used.

Cabinets

Select an available cabinet.

Magazines

Select one or more magazines from the
unassigned magazine list and move it to the
assigned magazine list. A partition MUST contain
at least one magazine.

Drives

Select a drive or drives from the unassigned
drives list and move it to the assigned drive list. A
partition MUST contain at least one drive.

SCSI Logical
Unit (LUN)

Enter the SCSI logical unit number for this
partition. Each partition must have a unique LUN
designation. The default number is 0.

Load Port

Select a load port from the load port list if
required for this partition. Load port elements can
be shared across multiple partitions.

Enable
Autoclean

Select this box to automatically clean the drives in
the partition when needed.

Emulate
P-Series

Select this box to return an P-Series inquiry string
to the host connected to this partition. The
partition will appear to the host as an P-Series
tape library.

Emulate Scalar
50

Select this box to return an Scalar 50 inquiry string
to the host connected to this partition. The
partition will appear to the host as an P-Series
tape library.

Enable Barcode
Swap

Enables/disables swapping media type prefix
from the back of barcode to the beginning.

106

Chapter 3 Quantum Scalar 50 Remote Management
Setup

Field

Description

Configured
Slots

The configured slots option allows you to
designate the number of slots available and
reported to the host. If you are reducing the slot
count, the slots are reduced from the highest
element address first. The element addressing
begins with the left magazine, then the right
magazine, and finally the fixed slots. This means
that the first slots reduced are the fixed slots.

3

Editing a Library Partition
To edit a library partition:
Note:

The library must be offline to create or edit a library partition.

1 Select the partition link under the Partitions section.
The area below the Partitions section displays the selected partition
settings.
2 Edit the partition information as desired (refer to table 29) and click
Apply to save the changes.
3 Click Clear to clear the partition settings and return to Creating a
Library Partition.

Quantum Scalar 50 User’s Guide

107

Chapter 3 Quantum Scalar 50 Remote Management
Setup

3

Deleting a Library Partition
There are two ways to delete partitions:
1 To delete a single library partition:
a Select the partition link under the Partitions section.
Note:

b

When a partition is added, edited, or deleted the library
must be rebooted for the changes to take effect.

Click Remove to delete the partition.
The library partition is deleted.

2 To delete all of the library partitions:
a Click Remove All.
All library partitions are deleted.

Field Service

3

The Field Service page is limited to Quantum Field Service only.

Setup Wizard

3

The Setup Wizard leads you through the process of setting up the most
common options for this library to be operational. Detailed customization
options, including settings modified by this wizard, can be changed via
the menus under the Setup tab.
Note:

The library will need to reboot for changes to take effect. Host
application software may need to be restarted/rebooted as
well.

1 To access the Setup Wizard, from the Setup page, click on the Setup
Wizard tab at the top of the page.
The Setup Wizard displays (see figure 72).

Quantum Scalar 50 User’s Guide

108

Chapter 3 Quantum Scalar 50 Remote Management
Setup

Figure 72 Setup Wizard

2 Click Next to continue.
The Setup Wizard (Library Offline) page displays (see figure 73).

Figure 73 Setup Wizard
(Library Offline)

3 Click Next to turn the library offline and continue.

Quantum Scalar 50 User’s Guide

109

Chapter 3 Quantum Scalar 50 Remote Management
Setup

The Setup Wizard (Date and Time) page displays (see figure 74).

Figure 74 Setup Wizard (Date
and Time)

4 Set the system date and time using the Change button for the system
date and drop down boxes for the system time.
5 Click Next to continue.
The Setup Wizard (Configure Devices) page displays (see figure 75).

Quantum Scalar 50 User’s Guide

110

Chapter 3 Quantum Scalar 50 Remote Management
Setup

Figure 75 Setup Wizard
(Configure Devices)

6 Set the SCSI ID for the SCSI devices in the library.
7 Click Next to continue.
The Setup Wizard (Configuring Load Ports) page displays (see
figure 76).

Figure 76 Setup Wizard
(Configuring Load Ports)

8 Enable or disable the load ports for this library.
9 Click Next to continue.

Quantum Scalar 50 User’s Guide

111

Chapter 3 Quantum Scalar 50 Remote Management
Setup

The Setup Wizard (Configuring Partitions) page displays (see
figure 77).

Figure 77 Setup Wizard
(Configuring Partition)

10 Create a partition for this library.
a

Enter a name for the partition.

b

Select a LUN for the partition.

c

Enable/disable Auto Clean for this partition.

11 Click Next to continue.
The Setup Wizard (Wizard Completed) page displays (see figure 78).

Quantum Scalar 50 User’s Guide

112

Chapter 3 Quantum Scalar 50 Remote Management
Secure Key

Figure 78 Setup Wizard
(Wizard Completed)

12 Click Exit to return to the Status page.
Note:

You must reboot the library for the changes to take effect.

The Setup Wizard is complete.

Secure Key
The Secure Key tab displays when a secure user has been added to the
library and the secure user is logged in.
Caution:

If the secure key information is lost, any tape cartridges
that were secured with the lost key will be unavailable for
reading or writing.

To access the Secure Key page, from the Setup page, click on the Secure
Key tab at the top of the page.
The Secure Key page displays (see figure 79).

Quantum Scalar 50 User’s Guide

113

Chapter 3 Quantum Scalar 50 Remote Management
Secure Key

Figure 79 Secure Key Page

Quantum Scalar 50 User’s Guide

114

Chapter 3 Quantum Scalar 50 Remote Management
Secure Key

The Secure Key page is divided into the following sections:
• Protection Mode for Cartridges
• Enable/Disable Secure Key for Drives
• Select Secure Key for Library
• Assign Secure Key to Cartridge
• Create Secure Key Name/Secure Key Pair
• Delete Secure Key Name
• Backup Secure Key File
• Upload Secure Key File

Protection Mode for
Cartridges

3

Refer to figure 80 for information on Protection Mode for Cartridges.

Figure 80 Protection Mode for
Cartridges

The Protection Mode for Cartridges area defines when the secure key is
used for a cartridge in a tape drive with a secure key enabled. In all
modes, the secure key is used to read data from cartridges that have a
pre-existing secure key. If the secure key on the cartridge does not match
the current secure key on the library, the data on the cartridge can not be
read.

Quantum Scalar 50 User’s Guide

115

Chapter 3 Quantum Scalar 50 Remote Management
Secure Key

Three write protection modes are available:
•

Never Write Secure Key to a Cartridge - The secure key will never

be written to a cartridge placed in a secured tape drive.
•

Only Write Secure Key to Blank Cartridges - The secure key will
only be written to blank, unformatted cartridges.

•

Write Secure Key to All Cartridges - The secure key will be written

to all cartridges, including blank and formatted cartridges
containing data. This mode may be used to apply a secure key to
cartridges with pre-existing data.

Enable/Disable Secure
Key for Drives
3

Refer to figure 81 for information on Enable/Disable Secure Key for Drives.

Figure 81 Enable/Disable
Secure Key for Drives

The secure key can only be used with tape drives that are secure key
capable. This section lists the tape drives in the library that are secure key
capable. A checkmark in the Secure Key column indicates a secure key is
enabled for the tape drive.
1 The secure key can be enabled or disabled for all tape drives by
clicking the corresponding radio button.
2 Click the Secure Key check box for individual tape drives to enable/
disable secure key for a tape drive.
3 Click Update to activate the changes.
Note:

Quantum Scalar 50 User’s Guide

The system must be offline to Enable/Disable Secure Key
setting for drives.

116

Chapter 3 Quantum Scalar 50 Remote Management
Secure Key

Select Secure Key for
Library

3

Refer to figure 82 for information on Select Secure Key for Library.

Figure 82 Select Secure Key
for Library

To select the secure key used by the library:
1 Select the secure key name from the list of available names.
Note:

Selecting None to will cause the library to NOT use a
secure key.

2 Click Update.
Note:

Assign Secure Key to
Cartridge

3

The system must be offline to modify a secure key.

Refer to figure 83 for information on Assign Secure Key to Cartridge.

Figure 83 Assign Secure Key
to Cartridge

Quantum Scalar 50 User’s Guide

117

Chapter 3 Quantum Scalar 50 Remote Management
Secure Key

Click Find to list all secured cartridges and their assigned secure key
names.
To assign a secure key to a cartridge:
1 Enter the barcode of the cartridge. Separate multiple barcodes with
either spaces or commas.
2 Select a secure key name from the list of available names.
3 Selecting Remove will remove the association between the cartridge
and a secure key name in the cartridge database.
4 Click Update to accept the changes.

Create Secure Key Name/
Secure Key Pair
3

Refer to figure 84 for information on Create Secure Key Name/Secure Key
Pair.

Figure 84 Create Secure Key
Name/Secure Key Pair

To create a secure key name/secure key pair:
1 Enter the Secure Key Name.
Note:

The secure key name must be less than 12 characters, may
include spaces, but cannot contain the following
characters: ( ) = ;

2 Enter a securekey in the protected Secure Key field.

Quantum Scalar 50 User’s Guide

118

Chapter 3 Quantum Scalar 50 Remote Management
Secure Key

3 Enter the same secure key in the Verify Secure Key field.
Note:

The Secure Key must be at least 8 characters and no more
than 32 characters. The Secure Key must also contain at
least one non-alphanumeric character and cannot include
spaces or double quotes (““).

4 Click New to create the secure key name/key pair.

Delete Secure Key Name3

Refer to figure 85 for information on Delete Secure Key Name.

Figure 85 Delete Secure Key
Name

The Secure Key Names maintained on the library are displayed in one of
three lists:
• Unused Secure Keys - keys not associated with any cartridges or tape
drives currently in the system.
• Inactive Secure Keys - keys associated with cartridges in the library,
or currently assigned to the library, but not assigned to any tape
drives.
• Active Secure Keys - keys currently assigned to a tape drive.
To delete a Secure Key Name/Secure Key pair from the library:

Quantum Scalar 50 User’s Guide

119

Chapter 3 Quantum Scalar 50 Remote Management
Secure Key

1 Select the desired Secure Key Names from the available lists.
2 Click Delete.
A confirmation message will be displayed, click Yes to continue.
Any tape drives that have been secure key enabled will remain
enabled, but the secure key will not be used to read or write
cartridges.

Backup Secure Key File 3

Refer to figure 86 for information on Backup Secure Key File.

Figure 86 Backup Secure Key
File

The list of Secure Key Name/Secure Key Pairs maintained on the library
should be backed up to a local device whenever a change is made to the
security keys.
Note:

Note the library's Encryption Key. The Encryption Key is
required when restoring the file to any library.

1 Click Save As...
The browser displays a download link.
2 Right-click on the download link and select Save As... to select a path
and name the file.
3 Click OK.

Quantum Scalar 50 User’s Guide

120

Chapter 3 Quantum Scalar 50 Remote Management
Secure Key

Upload Secure Key File 3

Refer to figure 87 for information on Upload Secure Key File.

Figure 87 Upload Secure Key
File

A file containing a list of Secure Key Name/Secure Key Pairs can be
restored to the library.
Note:

The user defined encryption key of the library originally
maintaining the list is required to restore the file.

To upload (restore) a Secure Key File:
1 Enter the encryption key of the original library.
2 Enter the path and file name of the file to be uploaded (click
Browse...)
3 Click Upload button.
A progress window is displayed indicating when the upload is
complete or if any errors occurred during the upload or restoration of
the file.
The Secure Key page is refreshed listing restored secure keys.
Note:

Quantum Scalar 50 User’s Guide

An error is displayed if the encryption key provided does not
match the encryption key used to encode the secure keys.

121

Chapter 3 Quantum Scalar 50 Remote Management
Secure Key Best Practices and Tape Migration

Secure Key Best Practices and Tape Migration
This section provides information on “Best Practices” when
implementing DLTSage Tape Security and also instructions for migrating
your security keys from one library to another.
For more information on implementing DLTSage Tape Security with
your specific library, refer to the following Quick Start Guides provided
on the documentation CD included in the library accessory kit:
• Scalar 50 DLTSage Tape Security Quick Start Guide PN 81-81627
• PX720 DLTSage Tape Security Quick Start Guide PN 81-81588

Best Practices

3

When implementing DLTSage Tape Security in your tape library, there
are several “Best Practices” or guidelines to consider:
• The encryption key file should be saved off of the library at least once
a month or whenever a large amount of tapes is removed/added to
the library. It is a good idea to use the date in the file name of the
backup file.
• In the library remote management pages, the secure key and tape
cartridge barcode associations are displayed when you click Find in
the Assign Secure Key to Cartridge section without a specific barcode
entered in the barcode edit box. You should save this file off of the
library so the secure key and barcode associations are available in
case of disaster recovery or when moving the tapes from one library
to another. This also makes it easy to copy and paste the barcode
numbers into the PX720 and Scalar 50 remote management pages
when associating barcodes with secure keys.
• Secure key and encryption password information should NOT be
stored in unsecured areas.

Key Migration Scenarios3

The following examples describe two key migration scenarios:
• Disaster Recovery Scenario
• Tape Cartridge Migration Scenario

Quantum Scalar 50 User’s Guide

122

Chapter 3 Quantum Scalar 50 Remote Management
Secure Key Best Practices and Tape Migration

3

Disaster Recovery Scenario
In the disaster recovery scenario, the original library is inoperable, but
secure keys and barcode associations have been saved off of the system
and are available on the network.
1 Remove the tape cartridges and place them in another tape security
enabled library.
2 Follow the steps listed below (beginning with step 2) to import
cartridges and associate barcodes with secure keys.

3

Tape Cartridge Migration Scenario
In this tape cartridge migration example, tape cartridges have been
secured in one tape library (PX720 or Scalar 50) and you want to move
them into another PX720 or Scalar 50 library and access them:
1 On the original library containing the cartridges:
a Access the library remote management screens.
b

In the Backup Secure Key file section, backup the secure key file.
This encrypted file contains all of the secure keys and bar code
associations in the original library. Once you click Save as... you
must right-click on the download link to save the file local
directory. This file must be located on a network resource that is
available to the new library.

c

Export the tape cartridges from the library.

2 On the new library:
a Import the tape cartridges into the new library.
b

c

Upload the secure key file from the original library:
•

If you are uploading a backup file from a PX720 to a Scalar 50
library, you must enter the serial number of the original
PX720 in the Encryption Key field, browse to the backup file,
and click Upload.

•

If you are uploading a file from a Scalar 50 library to a PX720,
you must enter the user defined key name in the Serial
number field, browse to the backup file, and click Upload.

When the file is uploaded, the secure keys from the original
library display in the secure key name list.

The tape cartridges are now available for reading and writing.

Quantum Scalar 50 User’s Guide

123

Chapter 3 Quantum Scalar 50 Remote Management
Utilities

Utilities
The Utilities page is divided into the following sections:
• Library
• System Tests
• Maintenance
• Logs
• Tasks
1 To access the Utilities page, from the Overview page, click on the
Utilities tab at the top of the page.
The Utilities page displays (see figure 88):

Figure 88 Utilities Page

Quantum Scalar 50 User’s Guide

124

Chapter 3 Quantum Scalar 50 Remote Management
Utilities

Library

3

The library page is divided into the following sections:
• Online/Offline
• Reboot Library
• Park for Shipping
• Bridge Rescan
To access the Library page, from the Utilities page, click on the Library tab
at the top of the page.
The Library page displays (see figure 89):

Figure 89 Library Page

Quantum Scalar 50 User’s Guide

125

Chapter 3 Quantum Scalar 50 Remote Management
Utilities

3

Online/Offline
The online/offline button allows the user to turn the cabinet online or
offline remotely. The action displayed on the button will depend on the
current state of the library or cabinet. If the library (cabinet) is online,
Offline button will be displayed. If the library (cabinet) is in the offline
state, an Online button will be displayed.
To change the library online/offline:
1 Click the button to change the library state to online or offline.
The library changes state to online or offline.

3

Reboot Library
The Reboot Library button allows you to remotely reboot the library.
To reboot the library:
1 Click Reboot.
The library reboots.

3

Park for Shipping
Note:

You must remove all tape cartridges from the library prior to
parking the library robotics for shipment.

The Park for Shipping button allows you to remotely park the robot for
library shipment. This places the library hand in the correct position for
shipment and powers down the library, HOWEVER, you must place the
library hand restraint on the library hand prior to shipping the library.
Refer to appendix D on page 216 for more information on shipping the
library.
Caution:

Shipping the library without installing the library hand
restraint may result in damaging the hand.

To park the library hand:
1 Select the cabinet and click the Park button.
The library hand moves to the shipment position.

Quantum Scalar 50 User’s Guide

126

Chapter 3 Quantum Scalar 50 Remote Management
Utilities

3

Bridge Rescan
Note:

The Bridge Rescan button only displays if a TC2201 iSCSI
bridge is installed in the library.

The bridge rescan button re-discovers any iSCSI bridges installed in the
cabinet. Details of the scan will be presented under Bridges tab.
To rescan iSCSI bridges installed in the cabinet:
1 Click Rescan.
The iSCSI bridges are scanned.

System Tests

3

The system tests section allows the user to run a series of tests on an
individual cabinet axis.
1 To access the System Test page, from the Utilities page, click on the
System Test tab at the top of the page.
The System Test page displays (see figure 90).

Figure 90 Selftest Page

Quantum Scalar 50 User’s Guide

127

Chapter 3 Quantum Scalar 50 Remote Management
Utilities

To run a Health Test on a cabinet:
Note:

The library must be off-line before executing any health tests.

1 Click the Start Test button.
The system performs a health test on all robotic axis. Previous test
results can be viewed below.

3

System Tests
The system test section allows the user to run a series of tests on an
individual cabinet axis.
1 To access the System Tests page, from the Utilities page, click on the
System Tests tab at the top of the page.
The System Tests page displays (see figure 91).

Figure 91 System Tests Page

Quantum Scalar 50 User’s Guide

128

Chapter 3 Quantum Scalar 50 Remote Management
Utilities

To run a System Test on a cabinet:
Note:

The library must be off-line before executing any system tests.

1 Select an action and a number of runs and click Apply.
The cabinet performs the system test. If you leave the runs field
empty, the system test will run continuously until you abort the
system test. Previous test results can be viewed below.

Maintenance

3

The maintenance section allows the user to backup or restore system
configuration files as well as upload new cabinet and tape drive
firmware.
1 To access the Maintenance page, from the Utilities page, click on the
Maintenance tab at the top of the page.
The Maintenance page displays (see figure 92).

Figure 92 Maintenance Page

Quantum Scalar 50 User’s Guide

129

Chapter 3 Quantum Scalar 50 Remote Management
Utilities

3

Configuration Files

Configuration files contain all of the configurable information on the
library (see table 30 for file types). This configuration file should be saved
on a local host on the same network. If the library configuration file is
corrupted, this backup configuration file can be uploaded back to the
library without reconfiguring the entire library.

Table 30 Configuration File
Types

Configuration File Type

Description

Backup

Select Backup to save all user, network,
and library configuration information.
Use this file to replace all configurable
options on the library.

Restore

Select Restore to restore a configuration
file from your computer to the library.

Factory

Select Factory to restore the library to its
default factory configuration settings.

1 Select file type and click on Apply.
Note:

After restoring configuration files or factory default settings,
the library will automatically reboot.

3

Upload Firmware
The upload firmware section allows the user to remotely upload new
firmware to the library.
Note:

If you are uploading library firmware to stacked libraries, refer
to Appendix E on page 226 for special instructions.

To upload firmware:
1 Enter a path and filename where the file exists, or click Browse.
2 Click Apply to upload the file.
Quantum Scalar 50 User’s Guide

130

Chapter 3 Quantum Scalar 50 Remote Management
Utilities

The firmware image uploads to the library and reboots the library.

3

Upload Drive Image
The upload drive image section allows the user to remotely upload new
tape drive firmware to a specific tape drive within the library.
To upload drive firmware:
Note:

The library must be offline to update the drive firmware.

1 Select an individual tape drive and number or select an entire cabinet
to update the drive firmware for all tape drives within the library
cabinet.
2 Enter a path and filename where the tape drive firmware exists, or
click Browse.
3 Click Apply to upload the file.
The firmware image uploads to the tape drive(s) and reboots the
library.

Logs

3

The Logs page displays the drive logs for the individual tape drives
within the library and also a failure analysis file.
To access the Logs page, from the Utilities page, click on the Logs tab at
the top of the page.
The Logs page displays (see figure 93):

Quantum Scalar 50 User’s Guide

131

Chapter 3 Quantum Scalar 50 Remote Management
Utilities

Figure 93 Logs Page

Click the View Log link to view the log file for a specific tape drive
(see figure 94). The log sense information for the tape drive displays.
Click Next to see additional log sense information.

Figure 94 View Log Page

Quantum Scalar 50 User’s Guide

132

Chapter 3 Quantum Scalar 50 Remote Management
Utilities

3

FA Log File

The failure analysis log file (FA log) contains diagnostic information used
to troubleshoot problems with the library. This file can only used by
Quantum Customer Support. Have this file available prior to calling
Quantum Customer Support.
Note:

It is recommended to turn the library offline prior to collecting
an FA log.

To retrieve a FA log file:
1 Click Retrieve.
A window displays with the status of the FA log download process.
This will take several minutes. Once the command to retrieve the
library FA log has completed, click the Download FA Log link to save
the file to your local computer.

Tasks

3

The Tasks page displays the last fifteen tasks that have been performed
on the library that required a status window. Clicking the task link
displays the task window whether it is still in progress or finished.
To access the Tasks page, from the Utilities page, click on the Tasks tab at
the top of the page.
The Tasks page displays (see figure 93):

Figure 95 Tasks Page

Quantum Scalar 50 User’s Guide

133

Chapter 3 Quantum Scalar 50 Remote Management
Reference

In the example above, a Move Operation task is displayed in the Task
Name list. Clicking the Move Operation link displays the following page
(see figure 96).

Figure 96 Task List Example

The page indicates that a move command has completed moving a tape
from cabinet 1 slot 17 to cabinet 1 address 0x1000, the start time and
elapsed time for the command to complete.

Reference
The links on this page provide access to various points of interest which
may be helpful in the operation and support of your library. Your
browser must have access to the internet for these links to work.
1 To access the Reference page, click on the Links tab at the top of the
page.
The Links page displays (see figure 97).

Quantum Scalar 50 User’s Guide

134

Chapter 3 Quantum Scalar 50 Remote Management
Reference

Figure 97 Reference Page

2 To access the About page, click the About tab at the top of the page.
The About page displays the model number, software version, serial
number, and slot/drive configuration (see figure 98).
Figure 98 About Page

Quantum Scalar 50 User’s Guide

135

Chapter 3 Quantum Scalar 50 Remote Management
Logout

Logout
The Logout page allows you to logout of the Scalar 50 remote
management pages.
To logout of the library remote management pages, click Logout.
The session is closed. Start a new session by re-authenticating when
prompted or close your browser.

Quantum Scalar 50 User’s Guide

136

Chapter 4

4

SNMP Trap List

This chapter provides the supported SNMP trap list for the Scalar 50 tape
libraries. The following table is sorted by the Reported By column:
1 Code Update
2 Diagnostic
3 Drive Manager
4 Event Manager
5 Image Process
6 OCP
7 SCSI
8 Servo
9 System Manager
10 System Monitor
Event Details - indicates the text that appears on the OCP and also in the
Remote Management web pages.
Event Description - provides a more detailed description of the event that

occurred.

Category - indicates the type of SNMP trap (Informational, Warning, or
Critical)
Reported By - indicates the area of firmware that reported the event.

Quantum Scalar 50 User’s Guide

137

Chapter 4 SNMP Trap List

Event Detail

Event Description

Category

Reported By

Start Backup System
Codeupdate (type/dest)

A backup flash update was
attempted.

Informational

Code update

Start Sled Codeupdate
(type/dest)

A drive sled update was
attempted.

Informational

Code update

Start Drive Codeupdate
(type/dest)

A drive update was attempted.

Informational

Code update

Loader Image size larger
than hdr entry (image
size)

The library failed the version
verification test.

Critical

Code update

Loader Image size
smaller than hdr entry
(image size)

The library failed the version
verification test.

Critical

Code update

Loader Image too large
for allocated memory
(image size)

The library failed the version
verification test.

Critical

Code update

Invalid boot image

The boot code used to initialize
the system is invalid. Update the
library firmware with the latest
version of code.

Critical

Code update

Invalid drive image
(type/dest)

The tape drive software
downloaded into the library
memory is invalid.

Critical

Code update

Invalid system image
(location)

The library software used for
system operation is invalid.
Update the library firmware with
the latest version of code.

Warning

Code update

Start System
Codeupdate (type/dest)

A loader update was attempted.

Informational

Code update

Codeupdate successful
(type/dest)

A code update has completed.

Informational

Code update

Quantum Scalar 50 User’s Guide

138

Chapter 4 SNMP Trap List

Event Detail

Event Description

Category

Reported By

Codeupdate failed
(status)

A code update has failed.

Informational

Code update

Backplane nv erase err
(region id/status)

Non Volatile memory on the back
plane could not be erased.
Replace the backplane to restore
normal library operations.

Critical

Diagnostics

Backplane nv read err
(region id/status)

Non Volatile memory on the back
plane could not be read. Replace
the backplane to restore normal
library operations.

Critical

Diagnostics

Backplane nv write err
(region id/status)

Non Volatile memory on the back
plane could not be written.
Replace the backplane to restore
normal library operations.

Critical

Diagnostics

Hand-camera image fail

The camera in the robotics hand
has failed to read an image.

Critical

Diagnostics

Hand-camera init fail

The camera in the robotics hand
has failed its initialization routine.

Critical

Diagnostics

Selftest Camera FIFO
failure

The camera in the robotics hand
has failed to read its memory used
to transfer data.

Critical

Diagnostics

Selftest display bram
failure

The diagnostic buffer used to
report test results is not large
enough to hold the data.

Critical

Diagnostics

Scb-fpga camera fifo fail

The memory on the system
controller board has failed to read
the memory used to transfer data.

Critical

Diagnostics

Test details buffer
overflow (len/testId)

The diagnostic buffer used to
report test results is not large
enough to hold the data.

Critical

Diagnostics

Test record semaphore
locked (index/tx-status)

An internal firmware error has
occurred.

Critical

Diagnostics

Quantum Scalar 50 User’s Guide

139

Chapter 4 SNMP Trap List

Event Detail

Event Description

Category

Reported By

Test structure corrupt
(testId)

An internal firmware error has
occurred.

Critical

Diagnostics

Insufficient num cart for
test (num)

Not enough tape cartridges in the
library to complete the system
test.

Warning

Diagnostics

Insufficient num drives
for test (num)

Not enough tape drives in the
library to complete the system
test.

Warning

Diagnostics

Insufficient num empty
slots for test (num)

Not enough empty bins in the
library to complete the system
test.

Warning

Diagnostics

Hand-cal offset fail

The calibration test used to
compute offsets for the robotic
hand has failed.

Critical

Diagnostics

Hand-theta cal offset fail

The calibration test used to
compute offsets for the robotic
hand in rotation has failed.

Critical

Diagnostics

Hand-trans cal offset fail

The calibration test used to
compute offsets for the robotic
hand in translation has failed.

Critical

Diagnostics

XY & hand cal offset fail

The calibration test used to
compute offsets for the robotics
tray has failed.

Critical

Diagnostics

XY & hand_theta cal
offset fail

The calibration used to compute
offsets for the robotics tray and
robotics hand has failed.

Critical

Diagnostics

XY & hand_trans cal
offset fail

The calibration test used to
compute offsets for the robotics
tray and robotics rotation has
failed.

Critical

Diagnostics

XY & Z cal offset fail

The calibration test used to
compute offsets for the robotics
tray and the robotics up/down
motion has failed.

Critical

Diagnostics

Quantum Scalar 50 User’s Guide

140

Chapter 4 SNMP Trap List

Event Detail

Event Description

Category

Reported By

XY-cal offset fail

The calibration test used to
compute offsets for the robotics
tray has failed.

Critical

Diagnostics

Z & hand cal offset fail

The calibration test used to
compute offsets for the robotics
tray up/down and robotics hand
has failed.

Critical

Diagnostics

Z & hand_theta cal offset
fail

The calibration test used to
compute offsets for the robotics
tray up/down and robotics hand
rotation has failed.

Critical

Diagnostics

Z & hand_trans cal offset
fail

The calibration test used to
compute offsets for the robotics
tray up/down and robotics hand
translation has failed.

Critical

Diagnostics

Z-cal offset fail

The calibration test used to
compute offsets for the robotics
tray up/down has failed

Critical

Diagnostics

Hand-trans axis init fail

The robotic hand could not
initialize the translation axis.

Critical

Diagnostics

Hand-trans home fail

The robotic hand could not home
the translation axis.

Critical

Diagnostics

Hand-trans motor fail
(zone #)

The robotic hand has failed to
position translation to a
predetermined physical location.

Critical

Diagnostics

Hand-theta axis fail
(zone #)

The robotic hand has failed to
position rotation to a
predetermined physical location.

Critical

Diagnostics

Hand-theta axis init fail

The robotic hand could not
initialize the rotation axis.

Critical

Diagnostics

Hand-theta home fail

The robotic hand could not home
the rotation axis.

Critical

Diagnostics

Quantum Scalar 50 User’s Guide

141

Chapter 4 SNMP Trap List

Event Detail

Event Description

Category

Reported By

Hand-theta motor fail
(zone #)

The robotic hand has failed to
position rotation to a
predetermined physical location.

Critical

Diagnostics

Hand-theta neg position
fail (zone #)

The robotic hand has failed to
position rotation to a
predetermined physical location.

Critical

Diagnostics

Hand-theta pos position
fail (zone #)

The robotic hand has failed to
position rotation to a
predetermined physical location.

Critical

Diagnostics

Hand-theta position fail

The robotic hand has failed to
position rotation to a
predetermined physical location.

Critical

Diagnostics

API msg que send
shutdown err (tx-status)

An internal API could not send a
shutdown message.

Critical

Diagnostics

API send response que
err (tx-status/fromId)

An internal API received a
command message error.

Critical

Diagnostics

API send test msg que
err (tx-status/fromId)

An internal API received a
command message error.

Critical

Diagnostics

Bad sender for get resp
que (taskId/sender)

An internal API received a
command message error.

Critical

Diagnostics

Create main msg que err
(tx-status)

An internal API received a
command message error.

Critical

Diagnostics

Create response msg que
err (tx-status)

An internal API received a
command message error.

Critical

Diagnostics

Main msg que receive
err (tx-status)

An internal API received a
command message error.

Critical

Diagnostics

Response msg que
receive err (tx-status)

An internal API received a
command message error.

Critical

Diagnostics

Create test record
semaphore err (tx-status)

An internal API received a
command message error.

Critical

Diagnostics

Quantum Scalar 50 User’s Guide

142

Chapter 4 SNMP Trap List

Event Detail

Event Description

Category

Reported By

Ralu rnd number
generator reset

The random number generator
used to calculate the slot locations
for the internal Random Access
Load Unload (RALU) function
has been reset.

Informational

Diagnostics

Elem move failed limits
check

A move to an element failed a
calibration limit.

Warning

Diagnostics

Hand-communication
fail

The communications to the
robotic hand has failed.

Warning

Diagnostics

XYZ-communication fail

The communication to the robotic
hardware for moving the X,Y and
Z axis has failed.

Warning

Diagnostics

Timeout waiting for
response (status/taskId)

A command sent by the
diagnostics module has timed out
waiting for a return from another
module in the system.

Critical

Diagnostics

Z-axis init fail

The Z (vertical) axis initialization
routine has failed.

Critical

Diagnostics

Z-motor fail (zone #)

The robotic hand has failed to
position the vertical axis to a
predetermined physical location.

Critical

Diagnostics

Z-position fail (zone #)

The robotic hand has failed to
position the vertical axis to a
predetermined physical location.

Critical

Diagnostics

X-position fail (zone #)

The robotic hand has failed to
position the XY axis to a
predetermined physical location.

Critical

Diagnostics

XY-home fail

The XY axis initialization routine
has failed to find its home
position.

Critical

Diagnostics

XY-motor fail (zone #)

The robotic hand has failed to
position the XY axis to a
predetermined physical location.

Critical

Diagnostics

Quantum Scalar 50 User’s Guide

143

Chapter 4 SNMP Trap List

Event Detail

Event Description

Category

Reported By

XY-position fail

The robotic hand has failed to
position the XY axis to a
predetermined physical location.

Critical

Diagnostics

XY-safe to rotate fail

The safe to rotate sensor used to
home the XY axis could not be
seen by the calibration routine.

Warning

Diagnostics

Y-position fail (zone #)

The robotic hand has failed to
position the XY axis to a
predetermined physical location.

Critical

Diagnostics

Bad SCSI Sense Data

A command sent to the drive
received bad sense data.

Warning

Drive
Manager

Aborted any open
exchanges

Drive communications has failed.

Informational

Drive
Manager

ADT login failed

The library failed to login and set
up communication to a drive.

Critical

Drive
Manager

Bad reply received

The drive did not return a valid
response.

Warning

Drive
Manager

Login failed, too many
retries

The library could not initiate
communications with the drive.

Warning

Drive
Manager

Login failed, no response

Drive did not respond correctly to
the login command sequence.

Warning

Drive
Manager

Unexpected login, not
handled or requested

The drive unexpectedly sent a
login request.

Informational

Drive
Manager

ACI invalid Response

The HP Gen 2 Drive returned an
invalid command response.

Warning
Critical

Drive
Manager

Command Id not
supported

This command is not supported
by the drive.

Critical

Drive
Manager

Could not send adt
logout

Drive communications (possibly
due to hardware) is lost.

Critical

Drive
Manager

Message Id not
supported

Command is not supported by the
drive.

Critical

Drive
Manager

Quantum Scalar 50 User’s Guide

144

Chapter 4 SNMP Trap List

Event Detail

Event Description

Category

Reported By

Response ServiceType
not supported

The drive does not support the
requested operation.

Warning
Critical

Drive
Manager

SCSI Response ptr is
NULL ptr

Drive did not return proper data
to the requested command.

Critical

Drive
Manager

SCSI unsupported
response code

Drive does not support the
requested command.

Critical

Drive
Manager

Too many busy retries

The drive has responded with too
may busy responses.

Warning

Drive
Manager

Unknown protocol type

Drive communication protocol is
not recognized.

Critical

Drive
Manager

Malloc block failed

The system has run out of internal
memory.

Critical

Drive
Manager

Drive wait que error

The system has run out of internal
memory.

Critical

Drive
Manager

Sema error

The operating system has failed to
create a resource.

Critical

Drive
Manager

Sema put failed

The operating system has failed to
create a resource.

Critical

Drive
Manager

Could not activate event
timer

The operating system has failed to
create a timer resource.

Warning

Drive
Manager

Could not activate util
timer

The operating system has failed to
create timer resource.

Warning

Drive
Manager

Could not change event
timer

The operating system has failed to
modify a timer resource.

Warning

Drive
Manager

Could not change util
timer

The operating system has failed to
modify a timer resource.

Warning

Drive
Manager

Quantum Scalar 50 User’s Guide

145

Chapter 4 SNMP Trap List

Event Detail

Event Description

Category

Reported By

System reset by
hardware (code/srr0)

Codes are:

Critical

Event
Manager

• CRITICAL 0x1111
• MACHINE_CHECK 0x2222
• ID_DATA_STORAGE 0x3333
• ISI_EXCEPTION 0x4444
• ALIGNMENT_EXCEPTION
x5555
• PROGRAM_EXCEPTION
x6666
• SYSTEM_CALL 0x7777FIT
0x8888
• WATCHDOG 0x9999
• INT_ID_DATA_TLB 0xAAAA
• INT_ID_INST_TLB 0xBBBB
• INT_ID_DEBUG 0xCCCC
• INT_ID_RESET
• srr0 is always 0

System reset by software
(0/0)

System has been reset by the
system software.

Critical

Event
Manager

System reset by
watchdog timer (0/0)

System has been reset by the
internal watchdog timer.

Critical

Event
Manager

System power failed
(0/0)

System power has failed internal
monitoring limits.

Critical

Event
Manager

(re)Booted for unknown
reason (post fail/
sled:qsb)

An unexpected reboot has
occurred.

Critical

Event
Manager

Quantum Scalar 50 User’s Guide

146

Chapter 4 SNMP Trap List

Event Detail

Event Description

Category

Reported By

Rebooted by hardware
trap (post fail/sled:qsb)

Serial Bus channel:

Informational

Event
Manager

• Drive Channel 89 - 0x00000200
• Drive Channel 67 - 0x00000100
• Drive Channel 45 - 0x00000080
• Drive Channel 23 - 0x00000040
• Drive Channel 01 - 0x00000020
• Front Panel - 0x00000010XYZ 0x00000008
• Hand - 0x00000004
• Regulator Module - 0x00000002
• Backplane - 0x00000001

Rebooted by software
trap (post fail/sled:qsb)

An unexpected reboot has
occurred.

Informational

Event
Manager

Rebooted by CPU
watchdog (post fail/
sled:qsb)

An unexpected reboot has
occurred.

Informational

Event
Manager

Rebooted by code load
(post fail/sled:qsb)

An unexpected reboot has
occurred.

Informational

Event
Manager

Powered on (post fail/
sled:qsb)

An unexpected reboot has
occurred.

Informational

Event
Manager

Booted after power
failed (post fail/
sled:qsb)

An unexpected reboot has
occurred.

Informational

Event
Manager

User requested reboot
(post fail/sled:qsb)

An unexpected reboot has
occurred.

Informational

Event
Manager

Quantum Scalar 50 User’s Guide

147

Chapter 4 SNMP Trap List

Event Detail

Event Description

Category

Reported By

Camera failed POST
(event class/failure
detail)

Event Classes:

Critical

Image proc

Critical

Image proc

• Internal Firmware Failure 0x24
• Operating System Failure - 0x43
and 0x44
• Camera Init Failure 0x7C
• Failure details are listed below.

Camera initialization
failed (camera code)

Failure Codes:
• Camera was reset, try
again0x0D
• Write data doesn't match read
data0x0C
• Counter doesn't match data
mount0x0B
• Interrupt not received at 3/
40x0A
• Interrupt received too
early0x09
• Problem reading control
regs0x08
• Problem writing control
regs0x07
• I2C channel problem0x06
• image data is truncated or
missing0x05
• Invalid image format0x04
• Can't set camera's data window
0x03
• Firmware bug detected 0x02
• Camera is not operating or
unrecognized 0x01
• No problems detected 0x00

Quantum Scalar 50 User’s Guide

148

Chapter 4 SNMP Trap List

Event Detail

Event Description

Category

Reported By

Camera was
unexpectedly reset

The internal camera has been reset
since the last time the system was
powered on.

Warning

Image proc

Couldn’t get mutex for
camera I2C (thrdx
status)

The operating system has failed to
create a resource.

Warning

Image proc

Unknown status for
OCP status LED (lib
status)

The Front Panel hardware is in an
unknown state.

Warning

OCP

Internal request to send
null SCSI CDB

The operating system failed to
create a proper SCSI command
data block.

Critical

SCSI

Queue insert failed when
receiving data out

The operating system has failed to
create a resource for the SCSI
module.

Critical

SCSI

SCB null in Release SCB

The information in the SCSI
command is not present.

Critical

SCSI

SCB null when receiving
data out

The information in the SCSI
command is not present.

Critical

SCSI

SCB null

The information in the SCSI
command is not present.

Critical

SCSI

Semaphore put failed
when receiving data out

The operating system has failed to
create a resource.

Critical

SCSI

Unexpected data out
received

Data out was received from the
host, but the SCSI server (the
current SCB) was not in a state to
receive the data.

Critical

SCSI

Unexpected data
received

Data in was unexpectedly sent to
the host

Critical

SCSI

Quantum Scalar 50 User’s Guide

149

Chapter 4 SNMP Trap List

Event Detail

Event Description

Category

Reported By

Unexpected response no non-immed

A response to an outstanding
non-immediate command was
received and SCSI server did not
know about the non-immediate
command.

Critical

SCSI

Unexpected response wrong state

A response to an outstanding
non-immediate command was
received and SCSI server did not
know about the non-immediate
command.

Critical

SCSI

No SCBs available

The operating system has failed to
create a resource.

Critical

SCSI

Release failed in Release
SCB

The operating system has failed to
create a resource.

Critical

SCSI

Queue insert failed when
receiving a SCSI
command

The operating system has failed to
create a resource.

Critical

SCSI

Queue insert failed

The operating system has failed to
create a resource.

Critical

SCSI

Semaphore put failed
when receiving a SCSI
command

The operating system has failed to
create a resource.

Critical

SCSI

Semaphore put failed

The operating system has failed to
create a resource.

Critical

SCSI

Servo Initialization
Failure

The system has failed to initialize
the robotics.

Critical

Servo

Cartridge not in hand
after get from magazine

The robotics did not detect a
cartridge present when a tape was
pulled from the magazine.

Warning

Servo

Servo Initialization Is
Complete

The system has succeeded in
initializing the robotics.

Informational

Servo

Quantum Scalar 50 User’s Guide

150

Chapter 4 SNMP Trap List

Event Detail

Event Description

Category

Reported By

Picker Axis Jammed

The portion of the robotics that
picks the tape can not move is
respective motor.

Warning

Servo

Picker Axis Position Lost

The portion of the robotics that
picks the tape can not move its
respective motor to the expected
internal limits.

Warning

Servo

Picker Axis Retry

The portion of the robotics that
picks the tape has exceeded
internal retries.

Warning

Servo

Picker Axis Stalled

The portion of the robotics that
picks the tape can not move its
respective motor to the expected
internal limits.

Warning

Servo

Picker Axis Timeout

The portion of the robotics that
picks the tape could not position
within its allotted time.

Warning

Servo

Theta Axis Jammed

The portion of the robotics that
rotates can not move its respective
motor.

Warning

Servo

Theta Axis Position Lost

The portion of the robotics that
rotates can not move its respective
motor to the expected internal
limits.

Warning

Servo

Theta Axis Retry

The portion of the robotics that
rotates theta has exceeded
internal retries.

Warning

Servo

Theta Axis Stalled

The portion of the robotics that
rotates can not move its respective
motor to the expected internal
limits.

Warning

Servo

Theta Axis Timeout

The portion of the robotics that
rotates theta could not position
within its allotted time.

Warning

Servo

Quantum Scalar 50 User’s Guide

151

Chapter 4 SNMP Trap List

Event Detail

Event Description

Category

Reported By

XY Axis Jammed

The portion of the robotics that
moves the XY axis can not move
its respective motor.

Warning

Servo

XY Axis Position Lost

The portion of the robotics that
moves the XY axis can not move
its respective motor to the
expected internal limits.

Warning

Servo

XY Axis Retry

The portion of the robotics that
moves XY has exceeded internal
retries.

Warning

Servo

XY Axis Stalled

The portion of the robotics that
moves the XY axis can not move
its respective motor to the
expected internal limits.

Warning

Servo

XY Axis Timeout

The portion of the robotics that
moves XY could not position
within its allotted time.

Warning

Servo

Z Axis Jammed

The portion of the robotics that
positions Up and Down can not
move its respective motor.

Warning

Servo

Z Axis Position Lost

The portion of the robotics that
moves the Up/Down axis can not
move its respective motor to the
expected internal limits.

Warning

Servo

Z Axis Retry

The portion of the robotics that
moves Up and Down has
exceeded internal retries.

Warning

Servo

Z Axis Stalled

The portion of the robotics that
moves the Up/Down axis can not
move its respective motor to the
expected internal limits.

Warning

Servo

Z Axis Timeout

The portion of the robotics that
moves Up and Down could not
position within its allotted time.

Warning

Servo

Quantum Scalar 50 User’s Guide

152

Chapter 4 SNMP Trap List

Event Detail

Event Description

Category

Reported By

Position to XYZ Failed

Robotics could not move to any
axis position.

Warning

Servo

Failed to read NVM
(status, region)

The robotics backplane has failed.

Critical

Sys manager

Failed to write NVM
(status, region)

The robotics backplane has failed.

Critical

Sys manager

Init element structure
failed

A firmware error has occurred.

Critical

Sys manager

Read from NV
(backplane SPI) failed
(status)

The robotics backplane has failed.

Warning

Sys manager

Could not convert GUI
addr to physical (elem
type/instance)

Bad element address.

Warning

Sys manager

Could not convert
logical addr to physical
(elem type/instance)

Bad element address.

Warning

Sys manager

Could not find drive
element in partition
(instance/part id)

Bad element address.

Warning

Sys manager

Could not find load port
in cabinet (instance/cab
index

Bad element address.

Warning

Sys manager

Could not find load port
in partition (instance/
part id)

Bad element address.

Warning

Sys manager

Could not find storage
element in cabinet
(instance/cab index)

Bad element address.

Warning

Sys manager

Could not find storage
element in partition
(instance/part id)

Bad element address.

Warning

Sys manager

Quantum Scalar 50 User’s Guide

153

Chapter 4 SNMP Trap List

Event Detail

Event Description

Category

Reported By

Drv type from dmgr is
not known (type)

A firmware error has occurred.

Critical

Sys manager

Failed to send response
(status)

A firmware error has occurred.

Critical

Sys manager

Invalid element type in
get SCSI Start Addr
(type/sys Id)

Bad element address.

Warning

Sys manager

Invalid element type in
get element count (type/
sys Id)

Bad element address.

Warning

Sys manager

Receive async element
status - invalid data type
(type)

A firmware error has occurred.

Critical

Sys manager

Receive async element
status - null element
(type, index)

A firmware error has occurred.

Critical

Sys manager

SCSI Address does not
convert to valid element
type (addr/sys id)

Bad element address.

Informational

Sys manager

Sensor grp unknown
(grp)

A firmware error has occurred.

Warning

Sys manager

Stack data received and
no buffer to store it (cab
index, offset)

A firmware error has occurred.

Warning

Sys manager

Stack message received
unexpectedly (cab index,
state)

A firmware error has occurred.

Warning

Sys manager

Unexpected response
received (txid/sender)

A firmware error has occurred.

Informational

Sys manager

Unknown cleaning
cartridge requested (drv
elemType)

A firmware error has occurred.

Critical

Sys manager

Quantum Scalar 50 User’s Guide

154

Chapter 4 SNMP Trap List

Event Detail

Event Description

Category

Reported By

Cleaning tape not found
(tape type)

An operation failed.

Warning

Sys manager

Cleaning tape not loaded
for clean op (drvNum)

An operation failed.

Critical

Sys manager

Drive cleaning operation
failed (drvNum, status)

An operation failed.

Critical

Sys manager

Stack message received
while one in progress
(cab index, offset)

A stack communication error has
occurred.

Informational

Sys manager

Allocate failed (threadX
status/pool)

A TX blk pool op error has
occurred.

Critical

Sys manager

Create data pool failed
(threadX status)

A TX blk pool op error has
occurred.

Critical

Sys manager

Create elem pool failed
(threadX status)

A TX blk pool op error has
occurred.

Critical

Sys manager

Create label pool failed
(threadX status)

A TX blk pool op error has
occurred.

Critical

Sys manager

Release failed (threadX
status)

A TX blk pool op error has
occurred.

Critical

Sys manager

Create failed (threadX
status/que)

A TX blk queue op error has
occurred.

Critical

Sys manager

Receive failed (threadX
status)

A TX blk queue op error has
occurred.

Critical

Sys manager

Send failed (msgid/
threadX status)

A TX blk queue op error has
occurred.

Critical

Sys manager

Create failed (threadX
status)

A TX blk semaphore op error has
occurred.

Critical

Sys manager

Create failed (threadX
status)

A TX blk timer op error has
occurred.

Critical

Sys manager

Shutdown timer expired
(task mask)

Time limit has expired.

Informational

Sys manager

Quantum Scalar 50 User’s Guide

155

Chapter 4 SNMP Trap List

Event Detail

Event Description

Category

Reported By

Fan speed critical(0,id)

Fan monitoring

Critical

Sys monitor

Fan speed warning(0,id)

• id Blake 0 B1|B2|B3 " PSU0"
• 1 B1|B2|B3 " PSU1"
• 2 B2|B3 " PSU2"
• 3 B2|B3 " PSU3"
• 4 B3 " PSU4"
• 5 B3 " PSU5"
• 6 B1|B2|B3 "Sled0"
• 7 B1|B2|B3 "Sled1"
• 8 B2|B3 "Sled2"
• 9 B2|B3 "Sled3"
• 10 B2|B3 "Sled4"
• 11 B2|B3 "Sled5"
• 12 B3 "Sled6"
• 13 B3 "Sled7"
• 14 B3 "Sled8"
• 15 B3 "Sled9"
• 16 B2|B3 "CPCI0"
• 17 B2|B3 "CPCI1"

FPGA program failed

The FPGA has failed.

Critical

Sys monitor

Unexpected error
returned from
smgrEventDriveInserted
(index,status)

A firmware error has occurred.

Critical

Sys monitor

Unexpected error
returned from
smgrEventDriveRemove
d(index,status)

A firmware error has occurred.

Critical

Sys monitor

Quantum Scalar 50 User’s Guide

156

Chapter 4 SNMP Trap List

Event Detail

Event Description

Category

Reported By

Unexpected error
returned from
smgrEventDriveSensorC
hange-QSB(index,status)

A firmware error has occurred.

Critical

Sys monitor

Unexpected error
returned from
smgrEventDriveSensorC
hangepower(index,status)

A firmware error has occurred.

Critical

Sys monitor

Unexpected error
returned from
smgrEventDriveSensorC
hangepower(index,status)

A firmware error has occurred.

Critical

Sys monitor

Unexpected error
returned from
smgrEventDriveSensorC
hange-temp(0,status)

A firmware error has occurred.

Critical

Sys monitor

Unexpected error
returned from
smgrEventPowerSupply
SensorChange(index,stat
us)

A firmware error has occurred.

Critical

Sys monitor

Unexpected error
returned from
smgrEventSensorChang
e-QSB(0,status)

A firmware error has occurred.

Critical

Sys monitor

Unexpected error
returned from
smgrEventSensorChang
e-adc(0,status)

A firmware error has occurred.

Critical

Sys monitor

Unexpected error
returned from
smgrEventSensorChang
e-doors(0,status)

A firmware error has occurred.

Critical

Sys monitor

Quantum Scalar 50 User’s Guide

157

Chapter 4 SNMP Trap List

Event Detail

Event Description

Category

Reported By

Unexpected error
returned from
smgrEventSensorChang
e-temp(0,status)

A firmware error has occurred.

Critical

Sys monitor

Unexpected error
returned from
smgrEventVarriesfans(0,status)

A firmware error has occurred.

Critical

Sys monitor

MAC Address is
Zero(index/index)

MAC address is not set.

Critical

Sys monitor

Drive Sled
Inserted(sled/0)

Normal operation

Informational

Sys monitor

Drive Sled
Removed(sled/0)

Normal operation

Informational

Sys monitor

Power Supply Inserted
(supply/0)

Normal operation

Informational

Sys monitor

Power Supply Removed
(supply/0)

Normal operation

Informational

Sys monitor

System Time Base
Set(msecs/seconds)

Normal operation

Informational

Sys monitor

System booted(build
type/version)

Normal operation

Informational

Sys monitor

Quantum Scalar 50 User’s Guide

158

Chapter 4 SNMP Trap List

Event Detail

Event Description

Category

Reported By

Monitored power level
critical(0,id)

Power monitoring

Warning
Critical

Sys monitor

Monitored power level
warning(0,id)

channel 0-1id

Blake Units

0

B2|B3 VOLTS "3.3v cpci_A"

1

B2|B3 VOLTS "5.0v cpci_A"

2

B2|B3 VOLTS "24v cpci_A"

3

B2|B3 VOLTS "24v cpci_B"

4

B3 VOLTS "24v cpci_C"

5

B2|B3 VOLTS "3.3v cpci_B"

6

B2|B3 VOLTS "5.0v cpci_B"

7

B3 VOLTS "3.3v cpci_C"

8
9

B3 VOLTS "5.0v cpci_C"
B2|B3 VOLTS "12v cpci"

10 B1|B2|B3 AMPS "24v buss_A current"
11 B1|B2|B3 VOLTS "3.3v scb"
12 B1|B2|B3 VOLTS "2.5v scb"
13 B1|B2|B3 VOLTS "1.8v scb"
14 B1|B2|B3 VOLTS "1.2v scb"
15 B1|B2|B3 PSID "psu0 ID"
16 B1|B2|B3 PSID "psu1 ID"
17 B1|B2|B3 VOLTS "psu0 24v"
18 B1|B2|B3 VOLTS "psu1 24v"
19 B1

VOLTS "12v cpci"

20 B2|B3 VOLTS "24v scb"
21 B1

VOLTS "5.0v scb/cpci"

22 B2|B3 AMPS "24v buss_B current"
23 B2|B3 PSID "psu2 ID"
24 B2|B3 PSID "psu3 ID"
25 B2|B3 VOLTS "psu2 24v"
26 B2|B3 VOLTS "psu3 24v"
27 B2|B3 VOLTS "5.0v scb"
28 B3 AMPS "24v buss_C current"
29 B3 PSID "psu4 ID"
30 B3 PSID "psu5 ID"
31 B3 VOLTS "psu4 24v"
32 B3 VOLTS "psu5 24v"

Power monitoring

Sys monitor

QSB Channel Errors
(channel/errors)

A QSB error has occurred.

Warning

Sys monitor

QSB Channel Failure
(channel/count)

A QSB failure has occurred.

Critical

Sys monitor

Quantum Scalar 50 User’s Guide

159

Chapter 4 SNMP Trap List

Event Detail

Event Description

Category

Reported By

QSB Channel Resyncs
(channel/resyncs)

A QSB resync has occurred.

Warning

Sys monitor

RTC Failure

The real time clock has failed.

Critical

Sys monitor

RTC Time not set

The real time clock has not been
set.

Informational

Sys monitor

Unknown board
revision(board/Board
Revision)

An unknown board revision has
been detected.

Critical

Sys monitor

Wrong CPLD
revision(board/CPLD
Revision)

Wrong CPLD revision detected.

Critical

Sys monitor

ADC Sensor
Communication
Failed(channel/id)

The SPI flash has failed.

Critical

Sys monitor

• channel 0-1id
• 2

SPI_ID_BP_ADC_1

• 3

SPI_ID_BP_ADC_2

• 14

SPI_ID_BRM_ADC

BP is over
temperature(old temp/
new temp)

The backplane has experienced an
over-temp condition.

Critical

Sys monitor

BRM is over
temperature(old temp/
new temp

The BRM has experienced an
over-temp condition.

Critical

Sys monitor

BRM1 is over
temperature(old temp/
new temp)

The BRM1 has experienced an
over-temp condition.

Critical

Sys monitor

BRM2 is over
temperature(old temp/
new temp)

The BRM2 has experienced an
over-temp condition.

Critical

Sys monitor

BRM3 is over
temperature(old temp/
new temp)

The BRM3 has experienced an
over-temp condition.

Critical

Sys monitor

Quantum Scalar 50 User’s Guide

160

Chapter 4 SNMP Trap List

Event Detail

Event Description

Category

Reported By

OCP is over
temperature(old temp/
new temp)

The OCP has experienced an
over-temp condition.

Critical

Sys monitor

HAND is over
temperature(old temp/
new temp)

The hand has experienced an
over-temp condition.

Critical

Sys monitor

SCB is over
temperature(old temp/
new temp)

The system controller board has
experienced an over-temp
condition.

Critical

Sys monitor

SLED0 is over
temperature(old temp/
new temp)

Sled 0 has experienced an overtemp condition.

Critical

Sys monitor

SLED1 is over
temperature(old temp/
new temp)

Sled 1 has experienced an overtemp condition.

Critical

Sys monitor

SLED2 is over
temperature(old temp/
new temp)

Sled 2 has experienced an overtemp condition.

Critical

Sys monitor

SLED3 is over
temperature(old temp/
new temp)

Sled 3 has experienced an overtemp condition.

Critical

Sys monitor

SLED4 is over
temperature(old temp/
new temp)

Sled 4 has experienced an overtemp condition.

Critical

Sys monitor

SLED5 is over
temperature(old temp/
new temp)

Sled 5 has experienced an overtemp condition.

Critical

Sys monitor

SLED6 is over
temperature(old temp/
new temp)

Sled 6 has experienced an overtemp condition.

Critical

Sys monitor

SLED7 is over
temperature(old temp/
new temp)

Sled 7 has experienced an overtemp condition.

Critical

Sys monitor

Quantum Scalar 50 User’s Guide

161

Chapter 4 SNMP Trap List

Event Detail

Event Description

Category

Reported By

SLED8 is over
temperature(old temp/
new temp)

Sled 8 has experienced an overtemp condition.

Critical

Sys monitor

SLED9 is over
temperature(old temp/
new temp)

Sled 9 has experienced an overtemp condition.

Critical

Sys monitor

Temp Sensor
Communication
Failed(channel/iic_id)

A temperature sensor has failed.

Critical

Sys monitor

• channel 0-9id
• 17

IIC_ID_TEMP_SCB

• 18

IIC_ID_TEMP_BP

• 19

IIC_ID_TEMP_BRM

• 20

IIC_ID_TEMP_BRM1

• 21

IIC_ID_TEMP_BRM2

• 22

IIC_ID_TEMP_BRM3

• 23

IIC_ID_TEMP_HAND

• 24

IIC_ID_TEMP_XY

• 25

IIC_ID_TEMP_Z

• 26

IIC_ID_TEMP_GUI

• 27

IIC_ID_TEMP_SLED0

• 28

IIC_ID_TEMP_SLED1

• 29

IIC_ID_TEMP_SLED2

• 30

IIC_ID_TEMP_SLED3

• 31

IIC_ID_TEMP_SLED4

• 32

IIC_ID_TEMP_SLED5

• 33

IIC_ID_TEMP_SLED6

• 34

IIC_ID_TEMP_SLED7

• 35

IIC_ID_TEMP_SLED8

• 36

IIC_ID_TEMP_SLED9

Quantum Scalar 50 User’s Guide

162

Chapter 4 SNMP Trap List

Event Detail

Event Description

Category

Reported By

XY is over
temperature(old temp/
new temp)

The XY axis motor has
experienced an over-temp
condition.

Critical

Sys monitor

Z is over
temperature(old temp/
new temp)

The Z axis motor has experienced
an over-temp condition

Critical

Sys monitor

Quantum Scalar 50 User’s Guide

163

Chapter 5

5

Troubleshooting

This chapter describes problems you may encounter during the setup
and operation of the Quantum Scalar 50 library. Corrective information
is provided to help you resolve the problems.
Several of these problems produce error messages on the OCP called
events (refer to chapter 4).
This chapter is divided into the following sections:
• Common Problems and Solutions
• Interpreting System LED Status

Common Problems and Solutions
The troubleshooting information in this section covers the following
topics:
• Start-up Problems
• OCP Problems
• Robotics (Hand) Problems
• Operating Problems

Quantum Scalar 50 User’s Guide

164

Chapter 5 Troubleshooting
Common Problems and Solutions

Start-up Problems

5 Table 31 describes corrective actions for problems which occur during

Table 31 Start-up Problems

start-up.

Problem

Corrective Action

The library does not
power on.

• Make sure all power cords are connected to
grounded electrical outlet.
• Press the power button located on the front
of the library.

The library or tape
drives do not
respond on the SCSI
bus.

Make sure each SCSI device on the same SCSI
bus has a unique address and the last device is
properly terminated.

During initialization,
the OCP displays
“ERR.” in the upper
right hand corner
and the LED located
under the buttons is
amber.

• Power the system down completely and
power it back on.

One or more tape
drives fails to power
up,

• Power on tape drives from the OCP.

The tape drives are
not visible from the
host system.

• Check all SCSI cabling and termination at
the back of the library. If necessary, contact
your field service representative about
replacing the drives.

• Determine the failure type by checking any
previous error codes returned to the host
computer.
• Check the event logs from the remote
management pages (see chapter 3 on
page 63).

• Remove and reinstall the tape drive.

• Power on tape drives from the OCP.
• Remove and reinstall the tape drive.

Quantum Scalar 50 User’s Guide

165

Chapter 5 Troubleshooting
Common Problems and Solutions

OCP Problems

5

Table 32 OCP Problems

Table 32 describes corrective actions for OCP problems.

Problem

Corrective Action

The OCP is blank.

• Physically remove the AC power by removing
all power cords from the power supply(s) and
reconnect them.
• Confirm that power is on and if the OCP is still
blank, contact an authorized Quantum field
service engineer (see “Contacts” on page xx).

Robotics (Hand)
Problems

5

Quantum Scalar 50 User’s Guide

The OCP does not
respond to
buttons.

• Verify that the buttons are not stuck
underneath the front bezel.

An error number
or event is
displayed.

Write down the error number and contact an
authorized Quantum field service engineer (see
“Contacts” on page xx).

• Physically remove the AC power by removing
all power cords from the power supply(s) and
reconnect them. Power the library on and if the
OCP still does not respond to buttons, contact
an authorized Quantum field service engineer
(see “Contacts” on page xx).

Table 33 describes corrective actions for robotics or hand problems.

166

Chapter 5 Troubleshooting
Common Problems and Solutions

Table 33 Robotics (Hand)
Problems

Problem

Corrective Action

The robot does not
move at power up.

• Make sure that all internal packing materials
(foam pads and metal straps) have been
removed.
• Check the library state on the OCP or remote
management pages. If Door Open is
displayed, make sure the front doors are
closed.
• Physically remove the AC power by removing
all power cords from the power supply(s) and
reconnect them. Power the library on and if
the robot still does not move, contact an
authorized Quantum field service engineer
(see “Contacts” on page xx).

The barcode reader
cannot read the
barcode and
displays “no
label”.

• Verify that nothing obstructs the reader.

The robot times
out or fails during
an operation.

• Check that the tape cartridge involved in the
operation is properly positioned in the slot or
drive and ready to be picked.

• It is recommended to avoid barcode reader
problems, to only use tape cartridge labels
provided by manufacturer.
• Reboot the library (see “Reboot Library” on
page 126). If the problem continues, contact an
authorized Quantum field service engineer
see “Contacts” on page xx).

• Check that the robot is not obstructed in any
way.
• Retry the operation. If it still fails, contact a
field service engineer.

Quantum Scalar 50 User’s Guide

167

Chapter 5 Troubleshooting
Common Problems and Solutions

Problem

Corrective Action

The robot drops a
cartridge.

• Open the doors.
• Retrieve the cartridge, orient it properly, and
place the cartridge in an empty storage slot.
(Do not try to place the cartridge in the hand.)
• Perform an inventory (see “Inventory Page”
on page 82).
• If the operator manually places a cartridge in
an empty slot, he must then run an inventory
so the library records the position of the
manually placed cartridge.

Operating Problems

5

Table 34 Problems During
Library Operation

Table 34 describes the corrective action for problems which occur during
library operation.
Problem

Corrective Action

The host computer
cannot
communicate with
the library.

This may be a SCSI bus time-out or a premature
disconnect problem.
Check cable connections, cable length, SCSI
addresses, and termination.
Restart the host and the library ensuring that
the library is “on-line” before the host is
restarted.
If the host and library still are not
communicating, contact an authorized
Quantum field service engineer see (“Contacts”
on page xx).

Quantum Scalar 50 User’s Guide

168

Chapter 5 Troubleshooting
Common Problems and Solutions

Problem

Corrective Action

A tape cartridge
(medium) is
reported not
present.

This indicates that the hand could not sense a
tape cartridge in a particular storage slot even
though the inventory reports that it is present.
The system performs optimally when tape
cartridge labels are present.
Check to see if the designated cartridge is
present. If it is, make sure it is properly seated.
(For a tape drive, make sure the cartridge is
completely unloaded.) Then retry the
command.
If the error persists, contact an authorized
Quantum field service engineer see (“Contacts”
on page xx).

A move command
failed.

Check the source and destination slots. The
source slot should hold the cartridge to be
moved; the destination slot should be empty.
Make sure the hand is empty and all actuators
are free of obstruction.
Retry the command.
Reboot the library (see “Reboot Library” on
page 126). If the problem continues, contact an
authorized Quantum field service engineer see
“Contacts” on page xx).

Quantum Scalar 50 User’s Guide

A flash memory
error is reported.

Contact an authorized Quantum field service
engineer.

A maximum
temperature
exceeded warning
is displayed.

Turn off the library and allow it to cool down.
Lower the room temperature, if possible, and
increase ventilation around the library.
(If the operating temperature is too high, the
library will automatically shut down until the
temperature drops.)

169

Chapter 5 Troubleshooting
Interpreting System LED Status

Problem

Corrective Action

Cleaning cartridge
marked as
unrecognized
media

Ensure that the cleaning cartridge has the
correct barcode label. You must use the correct
label for the cartridge type.

The remote
management pages
report the
following event:

From the OCP, power the tape drive off and
then back on.
If the drive is still logged out, contact Quantum
Technical Support “Contacts” on page xx.

surrogate drive
logged out

The remote
management pages
report the
following event:
surrogate drive
communication lost

The remote
management pages
report the
following event:
surrogate drive
unavailable - power
lost or canister
removed

From the OCP, power the tape drive off and
then back on.
If drive communication is still lost, contact
Quantum Technical Support “Contacts” on
page xx.
Check to see if the tape drive is installed.
If the drive is installed, reseat the tape drive by
removing and reinstalling the drive.
If the library still indicates that the power is lost
or canister removed, contact Quantum
Technical Support “Contacts” on page xx.

Interpreting System LED Status
The following system LED status indicators are available on the Scalar 50
libraries:
• Operator Control Panel (OCP) LED Status
• System Controller Board (SCB) LED Status

Quantum Scalar 50 User’s Guide

170

Chapter 5 Troubleshooting
Interpreting System LED Status

• Power Supply LED Status
• Tape Drive LED Status

Operator Control Panel
(OCP) LED Status
5

The OCP has an LED indicator reporting the library state (see table 35).

Table 35 OCP LED States

OCP

LED

Power button

System Controller Board
(SCB) LED Status
5

Quantum Scalar 50 User’s Guide

LED Status

Problem/Status

Green solid

The library is in an idle state.

Green flashing

The library is busy.

Amber flashing

The library is in an attention state.

Amber solid

An error has occurred on the library.

The SCB contains LED indicators that reports the state of the SCB and
Fibre Channel port (see table 36, table 37, and table 38).

171

Chapter 5 Troubleshooting
Interpreting System LED Status

Table 36 SCSI SCB LED
Customer network Internal network

SCB LED indicator

LED Status

Problem/Status

SCB LED Flashing

SCB good. Communicating.

SCB LED solid

• System busy.
• If the LED is solid for more than two minutes
and the library has been initialized, contact an
authorized Quantum field service engineer
see (“Contacts” on page xx).

SCB LED Off

• System idle.
• If the LED is off for more than two minutes
and the library has been initialized, contact an
authorized Quantum field service engineer
see (“Contacts” on page xx).

Quantum Scalar 50 User’s Guide

172

Chapter 5 Troubleshooting
Interpreting System LED Status

Table 37 Surrogate SCB LED
Customer network Internal network

SCB LED indicator

LED Status

Problem/Status

SCB LED Flashing

SCB good. Communicating.

SCB LED solid

• System busy.
• If the LED is solid for more than two minutes
and the library has been initialized, contact an
authorized Quantum field service engineer
see (“Contacts” on page xx).

SCB LED Off

• System idle.
• If the LED is off for more than two minutes
and the library has been initialized, contact an
authorized Quantum field service engineer
see (“Contacts” on page xx).

Quantum Scalar 50 User’s Guide

173

Chapter 5 Troubleshooting
Interpreting System LED Status

Table 38 Fibre Channel SCB
LED

Internal network

SCB LED indicator

Fibre Channel LED indicator

Customer network

LED Status

Problem/Status

SCB LED Flashing

SCB good. Communicating.

SCB LED solid

• System busy.
• If the LED is solid for more than two minutes
and the library has been initialized, contact an
authorized Quantum field service engineer
see (“Contacts” on page xx).

SCB LED Off

• System idle.
• If the LED is off for more than two minutes
and the library has been initialized, contact an
authorized Quantum field service engineer
see (“Contacts” on page xx).

Quantum Scalar 50 User’s Guide

Fibre Channel LED
solid

• Fibre Channel port has a good link.

Fibre Channel LED
Off

• Fibre Channel port is unplugged or does not
have a good link.

174

Chapter 5 Troubleshooting
Interpreting System LED Status

Power Supply LED Status 5 The power supplies have an LED indicator reporting the power supply
state (see table 39).

Table 39 Power Supply LEDs

LEDs

Quantum Scalar 50 User’s Guide

LED Status

Problem/Status

AC OK solid green

Power has been applied to the power supply and
is within specifications.

AC OK off

The power supply is not attached to a power
source or the power source has failed.

DC OK solid green

The power supply is providing DC power to the
library normally.

DC OK off

The power supply has failed.

175

Chapter 5 Troubleshooting
Interpreting System LED Status

Tape Drive LED Status

5

The tape drive canisters have LED indicators reporting the tape drive
state (see table 40).

Table 40 Tape Drive LEDs
Left yellow LED
(Fibre Channel 1)

Right yellow LED
(Fibre Channel 2)

Green activity LED

Quantum Scalar 50 User’s Guide

LED Status

Problem/Status

Green flashing

Drive good. Communicating.

Green solid

Drive failed

Off

No power to drive.

Left yellow on

Fibre Channel port active.

Right yellow on

Fibre Channel port active.

176

Appendix A

Specifications

A

This appendix lists the following specifications for the Scalar 50 libraries:
• Physical Specifications
• Performance Specifications
• Reliability Specifications
• Tape Drive Specifications
• Environmental Specifications
• SCSI Specifications

Quantum Scalar 50 User’s Guide

177

Appendix A Specifications
Physical Specifications

Physical Specifications
Table 41 Unit Dimensions/
Weight

Scalar 50
Width

19 in. (482 mm)

Depth

31 in. (762 mm.)

Height

6.75 in. (171 mm)

Weight

87 lbs. (39 kg) with 2 drives, 2 magazines, and 0 cartridges
installed

Table 42 Capacities

Scalar 50
Number of Tape Drives

Up to 2

Type of Tape Drives

DLT-S4 (SCSI and nFC), HP and
Quantum LTO Gen 3, HP LTO
Gen 4 (SCSI and nFC)

Number of Tape Cartridges

Up to 32 SDLT tape cartridges
Up to 38 LTO cartridges

Type of Tape Cartridges

For use with:
• DLT-S4 drives: DLT-S4 media
• HP LTO Gen drives: HP and
Quantum LTO-3 and HP LTO-4
Ultrium cartridges

Quantum Scalar 50 User’s Guide

Number of Magazines

Up to 2

Magazine Capacity

Each magazine holds up to 15
SDLT tape cartridges or up to 18
LTO tape cartridges

Manual Access Facility

Yes

178

Appendix A Specifications
Performance Specifications

Scalar 50
Robot Mounted Bar Code
Reader

Yes

Scalability

Yes

Performance Specifications
Table 43 Performance
Specifications

Scalar 50
Less than 14 seconds

Average Swap Time

Table 44 Library Performance

Tape
Drive

Maximum Data
Capacity
(Including
Fixed Slots)*

Maximum
Data
Throughput*

Host Interfaces

48 TB

51.2 TB

864 GB/hr

Ultra 320 SCSI and
Native Fibre Channel

Quantum
LTO Gen 3

28.8 TB

30.4 TB

490 GB/hr

LVD Ultra 3 SCSI and
Native Fibre Channel

HP LTO
Gen 3

28.8 TB

30.4 TB

1.1 TB/hr

LVD Ultra 3 SCSI and
Native Fibre Channel

HP LTO
Gen 4

57.6

60.8

1.7

DLT-S4
Scalar 50 (2 drives)

Data Capacity
(Excluding
Fixed Slots)*

LVD Ultra 3 SCSI, SAS,
and Native Fibre
Channel

* Assuming 2:1 compression ratios

Quantum Scalar 50 User’s Guide

179

Appendix A Specifications
Reliability Specifications

Reliability Specifications
Table 45 Reliability
Specifications

MSBF

Scalar 50 = 1,000,000 swaps

MTTR

Less than 30 minutes

Tape Drive Specifications
Table 46 Tape Drive
Specifications

Quantum Scalar 50 User’s Guide

Native Mode

With 2:1 Compression

Drive
Type

Transfer Rate

Capacity

Transfer Rate

Capacity

DLT-S4

3600 MB/min

800 GB

7200 MB/min

1600 GB

HP LTO
Gen 3

4800 MB/min.

400 GB.

9600 MB/min.

800 GB

HP LTO
Gen 4

4800 MB/min.

800 GB.

12000 MB/
min.

1.6 TB

180

Appendix A Specifications
Environmental Specifications

Environmental Specifications
Table 47 Power

Scalar 50
Electrical
Input
Tolerances

Table 48 Climate

Noise Levels

1

Voltage

90-264 VAC, 47-63 Hz

Power

300W (average)

Temperature
(Operating)

Temperature
(Non-Operating)

Temperature

+50°F to 95°F
(+10°C to +35°C)

-40°F to +149°F
(-40°C to +65°C)

Humidity

20% to 80%
non-condensing

10% to 90%
non-condensing

Altitude

-500 to +10,000 feet
(-152 to +3,048 meters)

-500 to +40,000 feet
(-152 to +12,192 meters)

The work area noise generated by the library amounts to 57.4 dB(A).
Deutch: Die arbeitsplatzbezogene Geräuschemission des Gerätes beträgt
57.dB(A).

SCSI Specifications
LVD SCSI configurations have a maximum allowable bus length of 12
meters (39 feet). To determine the cable length of the bus, measure the
lengths of the SCSI cables connecting each device to that bus and add
those lengths together. To that total length, add 12.25 inches (31.10 cm)
for the internal SCSI cable length of each SCSI tape drive.
Quantum Scalar 50 User’s Guide

181

Appendix B

SDLTtape Cartridge
Maintenance

B

This appendix provides guidelines for handling SDLT cartridges and
visually inspecting cartridges if necessary.

Handling DLTtape Cartridges
• Always keep each tape cartridge in its protective plastic case when it
is not in the library.
• When carrying tape cartridges in their cases, always orient the cases
so that the grooves in the cases interlock. This prevents the cases from
slipping apart and falling.
• Never stack more than five cartridges on top of each other.
• Always observe the proper environmental conditions for the storage
of tape cartridges. Refer to the cartridge reference card supplied with
each cartridge.
• When placing tape cartridges in archival storage, make sure you
stand each tape cartridge vertically.
• Avoid placing tape cartridges near any sources of high intensity
magnetic fields, such as computer monitors or electric motors.
Quantum Scalar 50 User’s Guide

182

Appendix B SDLTtape Cartridge Maintenance
Visual Inspection of DLTtape Cartridges

• Never apply adhesive labels or POST-IT notes to the top, side, or
bottom of your DLTtape cartridge. Only use the user slide- in type
label provided with each cartridge and slide it over the label slot on
the cartridge.
• Do not carry cartridges loosely in a box or any other container.
Allowing cartridges to bang together exposes them to unnecessary
physical shock.
• Do not touch or allow direct contact with tape or tape leader. Dust or
natural skin oils can contaminate the tape and impact tape
performance.
• Do not expose the tape cartridge to moisture or direct sunlight.
• Do not insert a dropped or damaged cartridge into a DLTtape drive
without, at the very least, a thorough visual inspection (see Visual
Inspection of DLTtape Cartridges). A dropped cartridge may have
dislodged, loosened, or damaged internal components.

Visual Inspection of DLTtape Cartridges
When To Visually Inspect
a DLTtape Cartridge
2

It is important to visually inspect a DLTtape cartridge under the
following circumstances:
• Whenever you change or load a new tape cartridge
• If the tape cartridge has been dropped or subjected to a physical
shock
• If a DLTtape drive becomes inoperable after loading the tape
cartridge
• If you receive a shipment of tape cartridges that shows any sign of
being damaged

Visual Inspection
Procedure

2

Quantum Scalar 50 User’s Guide

To visually inspect a DLTtape cartridge:
1 Check the cartridge for any obvious cracks or other physical damage.

183

Appendix B SDLTtape Cartridge Maintenance
Visual Inspection of DLTtape Cartridges

2 Gently shake the tape cartridge. Listen for any rattling of loose pieces
inside the cartridge.
Caution:

If you hear anything loose inside the cartridge, do not
use the cartridge.

3 Locate the reel lock openings (see figure 99) and verify that you can
see the reel locks.
The reel locks are small plastic tabs near the center of the reel lock
openings. They can be broken if the cartridge is dropped.
Caution:

If the reel locks are not visible, do not use the
cartridge.

Reel lock
opening

Figure 99 Location of the Reel
Locks and the Hub

Springloaded hub

Reel lock
opening

4 Verify that the spring-loaded hub (see figure 99) is centered within
the circular opening in the tape cartridge.
5 Gently press the hub, then release it. Make sure the hub springs back
into place and is still centered within its circular opening.
6 Open the tape cartridge door (see figure 100):
a Gently press up on the tab at the right side of the tape cartridge
door.
b

Quantum Scalar 50 User’s Guide

Swing the door open.

184

Appendix B SDLTtape Cartridge Maintenance
Visual Inspection of DLTtape Cartridges

Figure 100 Opening the Tape
Cartridge Door

Tape
cartridge
door

Tab

7 Verify that:
•

The tape is wound tightly on the reel

•

The tape leader loop is sticking up about an eighth of an inch

•

The tape leader loop is not bent or torn

Caution:

If any of the above conditions are not met, do not use
the cartridge.

8 Check for proper operation of the tape cartridge’s write-protect
switch (see figure 101).
The switch should snap back and forth, and the orange tab should be
visible when the switch is in the write-protected position.

Quantum Scalar 50 User’s Guide

185

Appendix B SDLTtape Cartridge Maintenance
Visual Inspection of DLTtape Cartridges

Figure 101 Write Protect
Switch

Write-protect
switch

Quantum Scalar 50 User’s Guide

186

Appendix C

Installing the Scalar 50
Library

C

This appendix explains how to install the Quantum Scalar 50 library.

Selecting an Installation Location
When choosing an installation site for the Scalar 50 library, consider the
following requirements:
• Rack Space Requirements
• Environmental Conditions

Quantum Scalar 50 User’s Guide

187

Appendix C Installing the Scalar 50 Library
Selecting an Installation Location

Rack Space Requirements

Figure
3 102 shows the minimum rack space required by the Scalar 50
library.
• Depth - 31 in (76.2 cm)
• Width - 19 in (48.3 cm)
• Height - 6.75 (17 cm)
• Weight - 52 lbs (23.6 kg)
• Clearance behind library - 4 in (10 cm) behind unit for proper air flow

Figure 102 Rack Space
Requirements

i
31

19

Quantum Scalar 50 User’s Guide

in (
48.

3c

o3
nt

n(
6i

.
78

o
8t

cm
91

m)

188

Appendix C Installing the Scalar 50 Library
Preparing for the Installation

Environmental
Conditions

3

Refer to appendix A on page 177 for environmental condition
information.

Preparing for the Installation
Before you begin the installation procedure in this section, make the
following preparations as described in this section:
• Providing Necessary Tools and Equipment
• Taking ESD Precautions

Providing Necessary
Tools and Equipment

3

Provide the following tools for installing the Scalar 50 library:
• 3 mm Allen wrench
• 2.5 mm Allen wrench
• #1 flat blade screwdriver
• Antistatic wrist strap included in accessory kit

Taking ESD Precautions 3

Some components within the Scalar 50 library contains static-sensitive
parts. To avoid damaging these parts while performing installation
procedures, always observe the following precautions:
• Keep the library turned off during all installation procedures.
• Use an antistatic wrist strap (included in the accessory kit).
• Keep static-sensitive parts in their original shipping containers until
ready for installation.
• Do not place static-sensitive parts on a metal surface. Place them
inside their protective shipping bag or on an antistatic mat.

Quantum Scalar 50 User’s Guide

189

Appendix C Installing the Scalar 50 Library
Installing the Library

• Avoid touching connectors and other components.
Note:

Dry climates and cold-weather heating environments
have lower relative humidity and are more likely to
produce static electricity.

Installing the Library
Installing a Scalar 50 library in a rack consists of the following steps:
• Locating the Mounting Position
• Installing the Library
• Loading the Tape Cartridges
• Initial Configuration

Locating the Mounting
Position

3

Table 49 Rack Hole Types

The Scalar 50 library is designed to fit in a standard 19 inch wide rack.
It is important to the library installation to locate the hole pattern in the
rack rails (see figure 50). The library must be installed at the beginning of
the hole pattern. Refer to table 49 for information on common rack hole
types.

Figure

Description

Cage nut

Square rack holes are the most common type of
rack holes. They can accept either cage nuts which
mount from the back of the rail or clip nuts which
clip on from the side of the rack rail.

Clip nut

Quantum Scalar 50 User’s Guide

190

Appendix C Installing the Scalar 50 Library
Installing the Library

Figure

Description
Clip nut

Through holes require clip nuts to accept
mounting hardware.

Threaded holes require neither cage or clip nuts to
accept mounting hardware.

Note:

Front panel
screws
1 Scalar 50 System (4U)

Table 50 Scalar 50 Rail Hole
Patterns and Mounting
Positions

The rails within the rack have a hole pattern that repeats
throughout the rail. X marks the screw positions. Install nut
clips (included in the accessory kit) on the rails if necessary.

4U

Back panel
screws
Front panel
screws
1U = 1.75

The marks above (X)
indicate the location of
mounting hardware on the
rack rails. Ensure that any
necessary mounting
hardware is installed on the
rack rails prior to installing
the chassis.

Quantum Scalar 50 User’s Guide

Hole pattern
Top of rack
.312 in (7.92 mm)
.625 in (15.9 mm)
.625 in (15.9 mm)
.5 in (12.7 mm)
.625 in (15.9 mm)
.625 in (15.9 mm)
.5 in (12.7 mm)

191

Appendix C Installing the Scalar 50 Library
Installing the Library

Warning:

Installing the Library

3

If the rack is empty at the time of installation, do NOT
install the Scalar 50 library too high in the rack. The
weight of the library may cause the rack to become “top
heavy” and unstable if installed in the top of an empty
rack. Begin installing the Scalar 50 library from the bottom
of the rack if more than one library is installed in the rack.

Installing the Scalar 50 library consists of the following steps:
• Installing the Rack Mount Shelves
• Installing the Library Chassis
• Cabling the Library

Table 51 Library Mounting
Hardware

Qty

Figure

Description

16

Allen head screws (M5 x 10) for shelf assembly

8

T- nuts (M5)

4 metric
and 4
standard

Rail adapters (both metric and standard holes are
included, 8 total adapters)

Quantum Scalar 50 User’s Guide

192

Appendix C Installing the Scalar 50 Library
Installing the Library

Qty

Figure

Description

2

Right and left support shelves (left shown)

4 sets

Front and back rail mounting hardware(M5 x 12 allen
screws and mounting plates)

2 sets

Back bracket hardware (M5 x 8 allen screws and
mounting plate)

2 sets

Back clamp hardware (M5 x 10 and back clamp)

Installing the Rack Mount Shelves

3

1 Assemble the rack mount shelves by (see figure 104):

Quantum Scalar 50 User’s Guide

193

Appendix C Installing the Scalar 50 Library
Installing the Library

a Loosely attach the adjustable shelves (right and left) with 4 M5 x
10 Allen screws and T-nuts.
Note:

b

T-Nuts must be oriented so they fit in the grooves of
the shelves.

Attach the appropriate rail adapter to the front and back of the
rack mount shelves (right and left) with 4 M5 x 10 Allen screws
(each rail adapter is marked with the specific hole type
supported, either metric or standard). The rail adapters have
arrows indicating the proper orientation (see figure 103).

Figure 103 Rail Adapter
Orientation

Keep the arrow up for
correct orientation

Quantum Scalar 50 User’s Guide

194

Appendix C Installing the Scalar 50 Library
Installing the Library

Figure 104 Assembling the
Left-Hand Rack Mount Shelves

Rail adapter

Allen screws

T-nuts

ft s
Le

lf
he

Allen screws

Rail adapter

Quantum Scalar 50 User’s Guide

Allen screws

FlexLink™ opening
located towards the
front for the left-hand
shelf

195

Appendix C Installing the Scalar 50 Library
Installing the Library

Figure 105 Assembling the
Right-Hand Rack Mount
Shelves

Allen screws

Rail adapter
T-nuts

Ri
gh

Allen screws

FlexLink opening
located towards the
back for the right-hand
shelf

ts

he
lf

Allen screws

Rail adapter

2 Install the left and right rack mount shelves into the rack (the rack
mount shelves adjust 27 in. to 36 in.) and secure with a mounting
plate and 2 M4 x 12 Allen screws at the front and back of the rack (see
figure 106).
Note:

Quantum Scalar 50 User’s Guide

The rack mount shelves must be installed on the inside
rack rails.

196

Appendix C Installing the Scalar 50 Library
Installing the Library

Figure 106 Installing the Rack
Mount Shelves

Mounting
plate

M4 x 12 Allen
screws

Left rack mount shelf

Fr o

nt

of

rac

k

Right rack mount shelf

3 Once the rack mount shelves are secured to the rack, tighten the
Allen screws securing the adjustable shelves together.

Quantum Scalar 50 User’s Guide

197

Appendix C Installing the Scalar 50 Library
Installing the Library

3

Installing the Library Chassis
Warning:

The Scalar 50 weighs approximately 65 lbs (29 kg) without
power supplies or tape drives. At least two people are
required to lift and install either library.

1 The back mounting brackets are lettered (A through I so the correct
mounting position is easily determined. The mounting positions
differ depending on the depth of the rack (see table 52).

Table 52 Back Mounting
Bracket Orientation

Rack Depth

Mounting Position

>27 to 28 in.

Use holes A and C

>28 to 29 in.

Use holes B and D

>29 to 30 in.

Use holes A and C

>30 to 31 in.

Use holes B and D

>31 to 32 in.

Use holes C and E

>32 to 33 in.

Use holes D and F

>33 to 34 in.

Use holes E and G

>34 to 35 in.

Use holes F and H

>35 to 36 in.

Use holes G and I

Once the location is determined, attach the back brackets to each side of
the library with four M5 x 8 Allen screws (see figure 107)
Note:

Quantum Scalar 50 User’s Guide

Use the shortest depth number. For example, if the
measurement is 34 in., use holes E and G.

198

Appendix C Installing the Scalar 50 Library
Installing the Library

Figure 107 Back Mounting
Brackets

Back mounting
bracket

Allen
screws

Right-hand back
bracket shown.

2 Install the library into the rack as shown (see figure 107).
Warning:

Quantum Scalar 50 User’s Guide

The Scalar 50 weighs approximately 65 lbs (29 kg)
without power supplies or tape drives. At least two
people are required to lift and install either library.

199

Appendix C Installing the Scalar 50 Library
Installing the Library

Figure 108 Installing the
Scalar 50 in the Rack

PHILLIPS screws

3 Secure the back of the library to the rack with two mounting clamps
and two Allen screws on each clamp. The mounting clamps are
oriented differently depending on the depth of the rack (see
figure 109).
Note:

If the rack depth is 27 to 30 in., the long portion of the
clamp is mounted to the back. If the rack depth is 30 to 36
in., the long portion is mounted to the front.

4 Secure the mounting clamps to the rack rails with two PHILLIPS
screws on each side (see figure 109).

Quantum Scalar 50 User’s Guide

200

Appendix C Installing the Scalar 50 Library
Installing the Library

Figure 109 Securing the Back
of the Library

Allen
screws

Long
portion

Right-hand back
bracket shown.

Warning: Hazardous Moving Parts.
Keep Fingers and Other Body
Parts Away When Removing
and Installing Tape
Drives.



Warnung: Gefährliche bewegliche
Teile. Halten Sie die
Finger und andere
Körperteile weg, wenn
Sie Bandlaufwerke
entfernen und
anbringen.

5 To install the tape drives into the library:

Quantum Scalar 50 User’s Guide

201

Appendix C Installing the Scalar 50 Library
Installing the Library

a Insert the tape drive into the drive bay slowly until the
connectors are seated (see figure 110).

Figure 110 Scalar 50 Tape
Drive Numbering

Tape
drive 2

Tape
drive 1

b

Tighten the tape drive captive screws using a flat blade
screwdriver.

c

Repeat these steps to install another tape drive in a different
location, if desired.

The library chassis is installed in the rack.

3

Cabling the Library
Connect the SCSI cables and jumpers as shown in the following figure:
• Scalar 50 Cable Configuration (SCSI Full Height Drives)
• Scalar 50 Cable Configuration (Native Fibre Channel Full Height
Drives)
• Scalar 50 Cable Configuration (SCSI Half-Height Drives)
• Scalar 50 Cable Configuration (SAS Half-Height Drives)

Quantum Scalar 50 User’s Guide

202

Appendix C Installing the Scalar 50 Library
Installing the Library

• Scalar 50 Cable Configuration (Native Fibre Channel Half-Height
Drives)
Note:

Quantum ships sufficient SCSI cables and terminators with the
libraries to set up two-drives per SCSI bus.

3

Stacked Configuration
• Scalar 50 Cable Configuration (Stacked)

Figure 111 Scalar 50 Cable
Configuration (SCSI Full Height
Drives)
Ethernet

SCSI host

System Controller Board

Tape drive 2

Power

Quantum Scalar 50 User’s Guide

Tape drive 1

Back of Library

203

Appendix C Installing the Scalar 50 Library
Installing the Library

Figure 112 Scalar 50 Cable
Configuration (Native Fibre
Channel Full Height Drives)
Ethernet

Fibre Channel host/SAN

Back of Library

Tape drive 2

LTO Tape drives
shown. SDLT drives
have a single FC port

Power

Fibre Channel
host/SAN

Tape drive 1

Fibre Channel
host/SAN

Figure 113 Scalar 50 Cable
Configuration (SCSI HalfHeight Drives)
Ethernet

SCSI host

Back of Library

Terminator

Tape drives
3 and 4

Power

Quantum Scalar 50 User’s Guide

SCSI host

Tape drives
1 and 2

Terminator

204

Appendix C Installing the Scalar 50 Library
Installing the Library

Figure 114 Scalar 50 Cable
Configuration (SAS Half-Height
Drives)
Surrogate Mode System
Controller Board ONLY

Ethernet

Tape drives 2

Power

Back of Library

Tape drives 1

SAS hosts

SAS hosts

Figure 115 Scalar 50 Cable
Configuration (Native Fibre
Channel Half-Height Drives)
Ethernet

Back of Library

Fibre Channel host/SAN

Tape drives
3 and 4

Power

Quantum Scalar 50 User’s Guide

Fibre Channel
host/SAN

Tape drives
1 and 2

Fibre Channel
host/SAN

205

Appendix C Installing the Scalar 50 Library
Installing the Library

Figure 116 Scalar 50 Cable
Configuration (Stacked)

Scalar 50 (slave library)

Tape
drive 2

Tape
drive 1

Host computer

Host computer
Scalar 50 (master library)

Ethernet

Tape
drive 2

Tape
drive 1

The library
host and
Ethernet
network are
connected only
to the Master
library.

Quantum Scalar 50 User’s Guide

206

Appendix C Installing the Scalar 50 Library
Installing the Library

Loading the Tape
Cartridges

3

Initial Configuration

3

Before operating the library, load the appropriate tape cartridges (LTO
and/or SDLT) into the library starting with the left-hand magazines
(refer to Preparing the Library for Operation on page 30 for more
information on tape cartridges).

Initially configuring the library consists of the following steps:
• Turning on the Library
• Setting the Date and Time
• Setting Network Information
Turning on the Library

3

To turn on the library:
1 Verify that:
•

Power cables are firmly in place

•

All doors are closed

2 Turn on the power switch located in the lower left-hand corner of the
OCP (see figure 117).

Quantum Scalar 50 User’s Guide

207

Appendix C Installing the Scalar 50 Library
Installing the Library

Figure 117 Turning On the
Library

OCP

Power button

3 When the library powers on for the first time after the hand has been
parked for shipping, the OCP asks you:
“Hand Restraint Found. Please Remove! Starting Shutdown...”

4 The OCP then displays:
“Doors opened, magazines released, pull magazines out before power
shutoff.”

The library waits approximately 30 seconds for you to open the
doors, remove both magazines from the library, and remove the hand
restraint.
Note:

If you are unable to remove the magazines before the
library shuts down. Turn on the library power and repeat
the steps above.

5 After the library has powered down, remove the hand restraint by
completing the following steps (see the Scalar 50 Quick Start Guide for
more information):
a

Quantum Scalar 50 User’s Guide

Remove the two thumb screws securing the hand restraint to the
base of the library.

208

Appendix C Installing the Scalar 50 Library
Installing the Library

b

Remove the hand restraint from the library.

Caution:

Avoid touching the printed circuit board.

Caution:

When removing the hand restraint, ensure that the
robotics umbilical cable is lying down in the correct
position inside the platform and not across the
robotics track.

c

Store the thumb screws and the restraining bolt in the hand
restraint.

d

Install the tape cartridge magazines.

e

Close the front doors.

6 Turn on the library by pushing power button located on the bottom
left-hand corner of the OCP (see figure 117).
7 The OCP asks you:
“Are the Shipping Restraints Removed?” (YES or NO).

8 Press YES to continue.
9 The OCP asks again:
“Are you sure the Hand & Thumb Screw Restraints have been
Removed?” (YES or NO).

10 Press YES to continue. The library continues the boot process. When
complete, the Home screen displays.
Note:

If the library encounters difficulties during the boot
process, there may be obstructions inside the library. The
the OCP will display: "Please Remove Restraining Bolt, or
Hand Restraint. See User's Guide.” Shut down the library,
open the doors with the emergency access tool and check
for obstructions. Be sure to check for the restraining bolt
on the left side of the cabinet.

11 Press Setup from the Home screen. The OCP displays the Setup
screen (see figure 118):

Quantum Scalar 50 User’s Guide

209

Appendix C Installing the Scalar 50 Library
Installing the Library

Figure 118 Setup Screen

Enter

12 From the Setup screen, use the up and down arrows to highlight
Cabinet and press Enter.
The Cabinet screen displays (see figure 119):

Figure 119 Library Options
Screen

13 The Stack role screen allows you to configure the library as a
“Master” or “Slave” in a multiple library stack. The library is
configured “Stand alone” by default. If this is a multiple library stack,
use the up and down arrows to highlight Stack role and press Enter
displays the following information about the library:
Note:

Quantum Scalar 50 User’s Guide

All Scalar 50 libraries must have FULL capacity before
configuration as a stack is possible. PX502 libraries in a
stack are considered fully licensed. Configure each unit
that will be stacked as a stand alone unit and enable Full
capacity through the remote management pages (see
Library on page 125). After full capacity is enabled, change
the stack role(s) accordingly to create the multiple library
stack.

210

Appendix C Installing the Scalar 50 Library
Installing the Library

Table 53 Setting Up the
Cabinet

Cabinet Options

Description

Host bus

Sets the SCSI ID for both the library
and tape drives.

Stack role

Assigns the library stack role as
Master, Slave, or Stand alone. There
can be only one Master library in a
multiple stack. Once configured as a
slave, all library OCP functions can be
controlled via the Master library OCP.

Left load port

Enables or disables the left load port

Right load port

Enables or disables the right load port

Drive FUP from tape

Allows you to perform a tape drive
firmware update from a firmware
update tape cartridge.

Setting the Date and Time

3

To set the date and time:
1 From the Setup screen, use the up and down arrows to highlight
Date and Time and press Enter.
The Date and Time screen displays (see figure 120):

Figure 120 Date and Time
Screen

The Date and Time screen displays the following information about
the library:

Quantum Scalar 50 User’s Guide

211

Appendix C Installing the Scalar 50 Library
Installing the Library

2 Use the up and down arrows to view or edit the date and time
information. Press Enter to accept the new settings.
3 When you are finished viewing/editing the date and time
information, press Exit to return to the Setup screen.

3

Setting Network Information
To view or edit the network information:
1 From the Setup screen, use the up and down arrows to highlight
Network and press Enter.
2 The Network screen displays (see figure 120):

Figure 121 Network Screen

The Network screen allows you to view or edit the following network
settings:
Note:

The network settings (IP address, subnet mask, and
default gateway) are only active when DHCP is disabled.

•

DHCP (default setting)

•

IP address

•

Subnet mask

•

Default gateway

3 Use the up and down arrows to select the network setting you wish
to view or edit and press Enter.
When you are finished viewing/editing the network information,
press Exit to return to the Setup screen.

Quantum Scalar 50 User’s Guide

212

Appendix C Installing the Scalar 50 Library
Emergency Library Access

4 For the network information such as the IP address to be active, you
must reboot the library by holding down the power button located on
the front of the library (see figure 117).
The library shuts down.
5 Push the power button to start the library.
The Scalar 50 tape library is initially configured and ready for use.

Emergency Library Access
Use the following procedure to gain access to the tape cartridge
magazines in case of an emergency and the library power is not available.
1 Put on an antistatic wrist strap and clip it to the library chassis
(example: a captive screw on the tape drive cover plates).
Caution:

Take standard ESD precautions when performing this
procedure.

2 Insert the door release tool included with the accessory kit into the
release holes and trip the magazine door release for both the right
and left magazine doors (see figure 122).
The magazine access doors open.

Quantum Scalar 50 User’s Guide

213

Appendix C Installing the Scalar 50 Library
Emergency Library Access

Figure 122 Opening the Right
and Left Magazine Access
Doors

Left magazine door

Door releases

Right magazine door

3 Insert the door release tool that is included in the library accessory kit
into the magazine release hole and trip the magazine release to
remove the each magazine from the library (see figure 123). Remove
both magazines from the library.
The tape cartridge magazines are now accessible.

Quantum Scalar 50 User’s Guide

214

Appendix C Installing the Scalar 50 Library
Emergency Library Access

Figure 123 Removing the
Magazines

Magazine release

Quantum Scalar 50 User’s Guide

215

Appendix D

Repacking the Scalar 50
Library

D

This document explains how to repack the Quantum Scalar 50 library.
Follow these instructions carefully to ensure the library is shipped
properly.
Note:

All Scalar 50 documentation is located on the Scalar 50
Documentation CD included in the library accessory kit.

Caution:

This procedure requires the packing materials originally
sent with the library for proper shipment. If you do not
have the library packing materials, contact Quantum
customer support for replacement packaging (800) 2845101.

This procedure consists of the following steps:

Quantum Scalar 50 User’s Guide

•

Removing the Library from the Rack

•

Installing the Internal Shipping Restraints

•

Packing the Library for Shipment

216

Appendix D Repacking the Scalar 50 Library
Removing the Library from the Rack

Removing the Library from the Rack

4

To remove the Scalar 50 library from the rack:
Note:

You must remove all tape cartridges from the library prior
to parking the library robotics for shipment.

1 Using the OCP, open the front doors, remove both tape cartridge
magazines, and remove any tape cartridges from the fixed bins or
FlexLink™ (refer to the Quantum Scalar 50 User’s Guide PN 81-81768
for information on OCP operation and bin locations).
After removing the tape cartridge magazines and closing the doors,
the library inventories all possible tape cartridge locations
(magazines, fixed slots, Flexlink, and tape drives). This process takes
several minutes.
2 From the Library Operations screen on the OCP, select Park for
Shipping. The library shuts down automatically.
Note:

If there are tape cartridges in the library, the system will
NOT park the library robotics. You must remove all tape
cartridges from the system prior to parking the library
robotics.

3 From the back of the library, disconnect all power, Ethernet, and SCSI
cables from the library and note their locations for later reinstallation.
Warning:

This unit has more than one power supply cord.
Disconnect all power supply cords before servicing to
avoid electric shock.

4 To remove the library chassis from the rack (see figure 124):
Note:

f

Quantum Scalar 50 User’s Guide

Refer to the Scalar 50 Quick Start Guide (PN 81-81767) for
additional Scalar 50 rack mount information.

Loosen the captive screws securing the tape drives to the chassis
and remove the tape drive(s) from the back of the library.

217

Appendix D Repacking the Scalar 50 Library
Removing the Library from the Rack

g

Loosen the captive screw securing the power supplies to the
chassis and remove the power supplies from the back of the
library.

h

Remove Phillips screws securing each side of the chassis to the
rack mounting rails and remove two Allen screws securing both
clamps on the back of the library.

i

Remove the library from the rack.
Warning:

Quantum Scalar 50 User’s Guide

At least two people are required to move the library
chassis.

218

Appendix D Repacking the Scalar 50 Library
Removing the Library from the Rack

Figure 124 Removing the
Scalar 50 Library

Tape drives

Power supplies

Right magazine

Quantum Scalar 50 User’s Guide

219

Appendix D Repacking the Scalar 50 Library
Installing the Internal Shipping Restraints

Installing the Internal Shipping Restraints
To ensure that the internal robotics within the library is not damaged,
you must install the internal shipping restraints on the robotics.
Caution:

Failure to install the shipping restraints on the robotics
may void your warranty.

To install the internal shipping restraints:
1 Place the library on a flat surface approximately waist high:
Note:

If the bottom FlexLink cover has been removed, replace it
before shipping the library back to Quantum.

2 Insert the emergency access tool included with the accessory kit into
the release holes and trip the magazine door release for both the right
and left magazine doors (see figure 125).
The magazine access doors open.

Quantum Scalar 50 User’s Guide

220

Appendix D Repacking the Scalar 50 Library
Installing the Internal Shipping Restraints

Figure 125 Opening the Right
and Left Magazine Access
Doors

Left magazine door

Door releases
Right magazine door

3 If the library is not operational and the Park for Shipping command
was not executed, grasp the robotics and gently move it to the front of
the library.
Caution:

Note:

Take standard ESD precautions when working within
the library chassis.

If there are any cartridges in the fixed bins, you can
remove them now.

4 Install the robotic restraint over the robotics and secure with two
thumb screws figure 126.
Quantum Scalar 50 User’s Guide

221

Appendix D Repacking the Scalar 50 Library
Installing the Internal Shipping Restraints

Figure 126 Installing
the Hand Restraint

Thumb
screws

Hand restraint

Hand restraint
installed

Quantum Scalar 50 User’s Guide

222

Appendix D Repacking the Scalar 50 Library
Installing the Internal Shipping Restraints

5 Replace the tape magazines and close the front doors.
6 Install the thumb screw restraint on the left-hand side of the library
chassis (see figure 127).

Figure 127 Installing the
Restraining Bolt

7 Install the tape drives, and power supplies previously removed in
Removing the Library from the Rack.
8 Install the tape cartridge magazines.

Quantum Scalar 50 User’s Guide

223

Appendix D Repacking the Scalar 50 Library
Packing the Library for Shipment

Packing the Library for Shipment
1 Carefully place the library into the antistatic bag.
2 Package the library into the shipping carton as shown in figure 128.
Ensure that the library chassis is placed in an antistatic bag before
placing the library in the shipping carton

Quantum Scalar 50 User’s Guide

Warning:

At least two people are required to move the library
chassis.

Caution:

Lift the library chassis at the sides. Avoid putting the
weight of the library chassis on the front bezel.

224

Appendix D Repacking the Scalar 50 Library
Packing the Library for Shipment

Figure 128 Preparing the
Library for Shipping

Accessories kit

Library chassis

Front bezel
Lift point

Shipping carton

Quantum Scalar 50 User’s Guide

225

Appendix E

Firmware Upgrade Instructions
for Stacked Libraries

E

If Scalar 50 libraries are in a multiple library stack, the library firmware
must be uploaded individually to each cabinet. If you attempt to upload
library firmware to only the Master library in the stack, the slave libraries
may not receive the firmware update properly.
Uploading library firmware to a multiple library stack consists of the
following steps:
Note:

Quantum Scalar 50 User’s Guide

If your libraries are partitioned, the partitioning information
will be lost after the firmware upgrade. You must recreate the
partitions after the firmware upgrade is complete.

•

Changing the Library Stack Role

•

Uploading Library Firmware

•

Returning the Library Stack Role

226

Appendix E Firmware Upgrade Instructions for Stacked Libraries
Changing the Library Stack Role

Changing the Library Stack Role
The library must be in Stand alone mode prior to receiving the library
firmware update.
To change the library stack role:
1 From the Operator Control Panel (OCP), press Setup from the Home
screen.
The OCP displays the Setup screen (see figure 129):

Figure 129 Setup Screen

Enter

2 From the Setup screen, use the up and down arrows to select Cabinet
and press Enter.
The Cabinet screen displays (see figure 130):

Figure 130 Cabinet Screen

3 Use the up and down arrows to select Stack role and press Enter.

Quantum Scalar 50 User’s Guide

227

Appendix E Firmware Upgrade Instructions for Stacked Libraries
Uploading Library Firmware

The Stack role screen displays.
Note:

Make note of the original stack role. You must return the
library to its original stack role after the library firmware
has been updated.

4 Use the up and down arrows to select Stand alone and press Enter.
The system prompts you with a confirmation screen asking Change to
Standalone and reboot this system?

5 Press Yes.
The library shuts down. Continue with Uploading Library Firmware.

Uploading Library Firmware
After the library stack role is set to Stand alone, you can upload library
firmware to the cabinet.
To upload library firmware:
1 Connect an Ethernet cable to the left-hand Ethernet port on the
library SCB and to a network host on the same subnet as the library
(see figure 131).
Note:

Quantum Scalar 50 User’s Guide

If this was the Master library, there will already be an
Ethernet cable connected to the library SCB.

228

Appendix E Firmware Upgrade Instructions for Stacked Libraries
Uploading Library Firmware

Figure 131 Connecting to the
Library SCB

Ethernet port

2 Use the OCP to determine the IP address for the library. The Network
information is available from the Info menu.
3 On the host computer, open the internet browser software.
4 In the Address field, type http://IPaddress/ where IP address is the IP
address for the library.
5 Enter the username and password and click OK.
Note:

The default username and password is admin.

The Overview page displays (see figure 132).

Quantum Scalar 50 User’s Guide

229

Appendix E Firmware Upgrade Instructions for Stacked Libraries
Uploading Library Firmware

Figure 132 Overview Page

6 Click the Utilities tab at the top of the page.
The Utilities page displays (see figure 133):

Quantum Scalar 50 User’s Guide

230

Appendix E Firmware Upgrade Instructions for Stacked Libraries
Uploading Library Firmware

Figure 133 Utilities
Page

7 Click the Maintenance tab at the top of the page.
The Maintenance page displays (see figure 134).

Quantum Scalar 50 User’s Guide

231

Appendix E Firmware Upgrade Instructions for Stacked Libraries
Uploading Library Firmware

Figure 134 Maintenance Page

8 To upload the library firmware, enter a path and filename where the
file exists, or click Browse.
Note:

Be sure to use the same library firmware for all libraries in
the stack.

9 Click Apply to upload the file.
The firmware image uploads to the library.
10 Reboot the library from the Utilities page (see figure 133).
The library reboots. Repeat the firmware upgrade procedure for
every library in the stack. When all libraries have been updated,
continue with Returning the Library Stack Role.

Quantum Scalar 50 User’s Guide

232

Appendix E Firmware Upgrade Instructions for Stacked Libraries
Returning the Library Stack Role

Returning the Library Stack Role
After the library firmware has been updated on all of the libraries and the
libraries have rebooted, you must return each library to its original
library stack role.
To return the library stack role:
1 From the OCP, press Setup from the Home screen.
The OCP displays the Setup screen (see figure 135):

Figure 135 Setup Screen

Enter

2 From the Setup screen, use the up and down arrows to select Cabinet
and press Enter.
The Cabinet screen displays (see figure 136):

Figure 136 Cabinet Screen

3 Use the up and down arrows to select Stack role and press Enter.
The Stack role screen displays.
Quantum Scalar 50 User’s Guide

233

Appendix E Firmware Upgrade Instructions for Stacked Libraries
Returning the Library Stack Role

4 Use the up and down arrows to select the appropriate stack role
(Master/Slave) for this library and press Enter.
The system prompts you with one of the following confirmation
screens asking:
•

Change to Master and reboot this system?

•

Change to Slave and reboot this system?

Note:

If stack role is changed to Master, there will be an
additional Attention screen that suggests the users to
remove the old master if the current stand alone cabinet is
added to an existing stack. Press Ok after confirmation.

5 Press Yes.
The library shuts down.
Note:

If the stack role is changed to Slave, the Ethernet cable can
be disconnected from cabinet's system controller board.

When all the libraries in the stack have been returned to their original
stack role, power on all of the libraries and return to normal operation.

Quantum Scalar 50 User’s Guide

234

Appendix F

F

Regulatory Statements

This appendix provides the regulatory statements for the Quantum
Scalar 50 libraries, in the following languages:
• English (page 208)
• Deutsch (seite page 238)
• Español (página page 240)
• Français (page page 243)
• Italiano (pagina page 245)
• Svenska (sidan page 247)
•

(Simplified Chinese) (page 249)

•

(Traditional Chinese) (page 251)

•

(Japanese) (page 253)

•

(Korean) (page 255)

English
FCC Statement

Quantum Scalar 50 User’s Guide

This equipment has been tested and found to comply with the limits for a
Class A digital device, pursuant to Part 15 of the FCC Rules. These limits
are designed to provide reasonable protection against harmful
235

Appendix F Regulatory Statements

interference when the equipment is operated in a commercial
environment. This equipment generates, uses, and can radiate radio
frequency energy and, if not installed and used in accordance with the
instruction manual, may cause harmful interference to radio
communications.
Any changes or modifications made to this equipment may void the
user's authority to operate this equipment.
Operation of this equipment in a residential area may cause interference
in which case the user at his own expense will be required to take
whatever measures may be required to correct the interference.
This device complies with Part 15 of the FCC Rules. Operation is subject
to the following conditions:
1 This device may not cause harmful interference, and
2 This device must accept any interference received, including
interference that may cause undesired operation.

Taiwan (BSMI) Statement


	

 
  
!" #$%&'()*+
,-.

Japan (VCCI) Statement

Quantum Scalar 50 User’s Guide

236

Appendix F Regulatory Statements

DEN-AN Notice (Japan
Industry Canada Digital
Apparatus)

Reference: Interference-Causing Equipment Standard, ICES-003, Issue 2
This Class A digital apparatus meets all requirements of the Canadian
Interference-Causing Equipment Regulations.

CISPR-22 Warning!

This is a Class A product. In a domestic environment this product may
cause radio interference in which case the user may be required to take
adequate measures.

Notice for USA and CANADA Only
If shipped to USA, use the UL LISTED power cord specified below for
100-120 V operation. If shipped to Canada, use the CSA CERTIFIED
power cord specified below for 100-120V operation.

Quantum Scalar 50 User’s Guide

Plug Cap

Parallel blade with ground pin (NEMA 5-15P
configuration)

Cord

Type: SJT, three 16 AWG (1.5 mm2) or
18 AWG (1.0 mm2) wires

Length

Maximum 15 feet (4.5m)

Rating

Minimum 10 A, 125 V

237

Appendix F Regulatory Statements

Laser Statement

6

CAUTION: With all panels and enclosures in place, this product is rated
as a Class I laser product.
CAUTION: Use of controls or adjustments or performance of procedures
other than those specified herein may result in hazardous exposure.

Library Battery Statement

CAUTION: This product contains a Lithium battery. Lithium may be
considered a hazardous material. Dispose of this battery in accordance
with local, state, and federal laws. The Lithium batteries included in this
product are:
• Panasonic BR1225
• IC Battery ST Micro M41T81

6

Battery Contained in Product:
“Perchlorate Material – special handling may apply, See
www.dtsc.ca.gov/hazardouswaste/perchlorate.”
•

The foregoing notice is provided in accordance with California
Code of Regulations Title 22, Division 4.5 Chapter 33, Best
Management Practices for Perchlorate Materials. This product/
part includes a lithium battery which contains a perchlorate
substance.

Deutsch
Regelungen der FCC

Quantum Scalar 50 User’s Guide

Nach Tests wurde festgelegt, dass dieses Gerät den digitalen Geräten der
Klasse A entspricht und den Vorschriften in Abschnitt 15 der Regelungen
der FCC unterliegt. Durch diese Vorschriften wird ein angemessener
Schutz vor schädlichen Strahlungen gewährleistet, wenn dieses Gerät in
einer kommerziellen Umgebung betrieben wird. Von den Geräten wird
Hochfrequenzenergie erzeugt, genutzt und abgestrahlt, die bei einer im
Widerspruch zu diesem Handbuch stehenden Installation oder Nutzung
Funkstörungen erzeugen kann.

238

Appendix F Regulatory Statements

Änderungen und Modifikationen an diesem Gerät können zum
Erlöschen der Betriebserlaubnis für dieses Gerät führen.
Der Betrieb dieses Geräts in Wohngegenden kann zu Empfangsstörungen
führen, die der Verursacher auf eigene Kosten beheben muss.
Dieses Gerät erfüllt die Vorschriften in Abschnitt 15 der Regelungen der
FCC. Der Betrieb unterliegt den folgenden Bedingungen:
1 Das Gerät darf keine schädlichen Störungen hervorrufen und
2 Das Gerät muss alle eingehenden Störungen aufnehmen,
einschließlich Störungen, die einen unerwünschten Betrieb
verursachen können.

Regelungen für Taiwan


	

 
  
!" #$%&'()*+
,-.

Industry Canada (DigitalApparate)

Referenz: Norm für störungsverursachende Geräte, ICES-003, Ausgabe 2
Dieses Digitalgerät der Klasse A erfüllt alle Anforderungen der
kanadischen Vorschriften bezüglich störungsverursachender Geräte
(Canadian Interference-Causing Equipment Regulations).

CISPR-22 Warnung!

Dies ist ein Produkt der Klasse A. Dieses Produkt kann in
Wohngegenden Funkstörungen verursachen, die vom Verursacher durch
angemessene Maßnahmen behoben werden müssen.

Hinweis nur für USA und
KANADA

Wenn dieses Produkt in die USA geliefert wird, muss das nachstehend
für einen 100-120-Volt-Betrieb spezifizierte und von UL zugelassene
Netzkabel verwendet werden. Wenn dieses Produkt nach Kanada
geliefert wird, muss das nachstehend für einen 100-120-Volt-Betrieb
spezifizierte und von CSA zugelassene Netzkabel verwendet werden.

Quantum Scalar 50 User’s Guide

239

Appendix F Regulatory Statements

SteckerausführungParallele Steckzungen mit Erdungsstift
(NEMA 5-15P-Konfiguration)

Laser-Erklärung

Kabel

Typ: SJT, drei 16 AWG (1,5 mm2)- oder
18 AWG (1,0 mm2)-Leiter

Länge

Max. 15 Fuß (4,5 m)

Nennleistung

Min. 10 A, 125 V

VORSICHT: Wenn alle Abdeckungen und Gehäuseteile korrekt
angebracht sind, handelt es um ein Produkt der Laserklasse 1. Der
Strichcodescanner in diesem Produkt ist jedoch ein Laser Klasse II.
Vermeiden Sie die Aussetzung an die von dem Strichcodescanner
ausgehenden Strahlen. Blicken Sie nicht direkt in den Strahl.
VORSICHT: Die unsachgemäße Verwendung von Bedienelementen
oder Einstellungen bzw. die Ausführung von Arbeitsschritten, die nicht
in der mit dem Gerät gelieferten Dokumentation beschrieben sind,
können dazu führen, dass gesundheitsschädigende Strahlungen
freigesetzt werden.

Hinweis zur
Bibliotheksbatterie

VORSICHT: Dieses Produkt enthält eine Lithium-Batterie. Das
nichtflüchtige RAM, Dallas Semiconductor DS1743-100, enthält eine
Lithium-Batterie. Lithium ist eventuell als gefährliches Material zu
betrachten. Die Entsorgung dieser Batterie muss unter Einhaltung aller
lokalen, regionalen und bundesweiten Gesetze und Vorschriften
erfolgen.

Español
Declaración FCC

Quantum Scalar 50 User’s Guide

Este equipo ha sido sometido a prueba y ha demostrado cumplir con los
límites de un dispositivo digital de Clase A, conforme a la Parte 15 de las
Normas FCC. Estos límites están diseñados para proporcionar una
protección razonable contra las interferencias perjudiciales cuando el

240

Appendix F Regulatory Statements

equipo funciona en un entorno comercial. Este equipo genera, usa y
puede emitir energía de radiofrecuencia y, si no se instala ni se usa de
acuerdo con el manual de instrucciones, puede provocar interferencias
perjudiciales para las comunicaciones de radio.
Cualesquiera cambios o modificaciones realizados a este equipo pueden
anular la autoridad del usuario para utilizar este equipo.
El uso de este equipo en un área residencial puede provocar
interferencias, en cuyo caso será el usuario quien tenga que correr con los
gastos de las medidas que puedan ser necesarias para corregir las
interferencias.
Este dispositivo cumple con la Parte 15 de las Normas FCC. El
funcionamiento está sujeto a las siguientes condiciones:
1 Este dispositivo no debe causar interferencias perjudiciales, y
2 Este dispositivo debe aceptar cualquier interferencia que reciba,
incluidas aquéllas que puedan provocar un funcionamiento no
deseado.

Declaración para Taiwán


	

 
  
!" #$%&'()*+
,-.

Industria de Canadá
(Aparato digital)

Referencia: Interference-Causing Equipment Standard (Estándar para equipos
que causan interferencia), ICES-003, Issue 2 (Tema 2)
Este aparato digital de Clase A cumple todos los requisitos de la
normativa canadiense sobre equipos que causan interferencia.

Advertencia CISPR-22

Quantum Scalar 50 User’s Guide

Éste es un producto de Clase A. En un entorno doméstico, este producto
puede causar interferencias de radio, en cuyo caso puede ser necesario
que el usuario tome medidas adecuadas.

241

Appendix F Regulatory Statements

Aviso sólo para EE.UU. y
CANADÁ

Declaración sobre láser

Si el producto se ha fabricado para EE.UU., utilice el cable de
alimentación UL LISTED que se especifica más adelante para el
funcionamiento a 100-120 V. Si el producto se ha fabricado para Canadá,
utilice el cable de alimentación CSA CERTIFIED que se especifica más
adelante para el funcionamiento a 100-120 V.
Enchufe

Cuchilla paralela con patilla de conexión a tierra
(configuración NEMA 5-15P)

Cable Tipo

SJT, tres cables 16 AWG (1,5 mm2) ó
18 AWG (1,0 mm2)

Longitud

Máxima de 15 pies (4,5m)

Clasificación

Máximo 10 A, 125 V

PRECAUCIÓN: Con todos los paneles y cubiertas en su sitio, este
producto se clasifica como un producto láser de Clase I. Sin embargo, el
lector de código de barras que hay en el interior de este producto es un
láser de Clase II. Evite la exposición a la luz del láser que emite el lector
de código de barras. No mire fijamente el rayo.
PRECAUCIÓN: El uso de controles o ajustes o la realización de
procedimientos distintos de los que se especifican en este manual pueden
provocar una exposición peligrosa.

Declaración sobre la
batería de la biblioteca

Quantum Scalar 50 User’s Guide

PRECAUCIÓN: Este producto contiene una batería de litio. La memoria
RAM no volátil, Dallas Semiconductor DS1743-100, contiene una batería
de litio. El litio puede ser considerado un material peligroso. Deseche la
batería conforme a la norma vigente de aplicación local, del estado y
federal.

242

Appendix F Regulatory Statements

Français
Déclaration de la FCC

Cet équipement a été testé et s'est révélé conforme aux limites d'un
appareil numérique de Classe A, conformément à l'alinéa 15 de la
réglementation de la FCC. Ces limites sont conçues pour fournir une
protection adéquate contre les perturbations nuisibles lorsque
l'équipement fonctionne dans un environnement commercial. Cet
équipement génère, utilise et peut émettre une énergie à fréquence radio
et risque, s'il n'est pas installé et utilisé conformément au manuel
d'instruction, de créer des perturbations nuisibles aux services de
radiocommunication.
Tout changement ou modification apporté à cet équipement risque
d'annuler le droit d'utiliser l'équipement.
L'utilisation de cet équipement dans une zone résidentielle risque de
créer des perturbations auxquelles l'utilisateur devra remédier à ses
propres frais.
Cet appareil est conforme à l'alinéa 15 de la réglementation de la FCC. Le
fonctionnement de cet équipement est soumis aux conditions suivantes :
1 Cet appareil ne peut générer de perturbations nuisibles et
2 Cet appareil doit accepter les perturbations reçues, notamment les
perturbations qui risquent de générer un fonctionnement non
souhaité.

Réglementation de Taïwan


	

 
  
!" #$%&'()*+
,-.

Quantum Scalar 50 User’s Guide

243

Appendix F Regulatory Statements

Industrie Canada
(Appareil numérique)

Référence : Norme sur le matériel brouilleur, NMB-003, numéro 2

Avertissement CISPR-22 !

Ceci est un produit de Classe A. Dans un environnement résidentiel, ce
produit risque de générer des perturbations radio auxquelles l'utilisateur
doit peut-être remédier.

Avis pour les États-Unis et
le Canada uniquement

En cas d'envoi aux États-Unis, utilisez le câble d'alimentation CLASSÉ UL
spécifié ci-dessous pour un fonctionnement à 100-120 V. En cas d'envoi
au Canada, utilisez le câble d'alimentation CERTIFIÉ CSA spécifié cidessous pour un fonctionnement à 100-120 V.

Cet appareil numérique de Classe A satisfait à toutes les exigences des
réglementations canadiennes sur le matériel brouilleur.

Fiche

Broche parallèle avec broche de mise à la terre
(configuration NEMA 5-15P)

Cordon

Type : SJT, trois fils 16 AWG (1,5 mm2) ou
18 AWG (1,0 mm2)

Longueur

15 pieds (4,5 m) au maximum

Courant nominal10 A au minimum, 125 V

Réglementation relative
au laser

ATTENTION : Avec tous les panneaux et enceintes en place, ce produit
est classé comme un produit laser de Classe I. Le lecteur de codes-barres à
l'intérieur de ce produit est, cependant, un laser de Classe II. Évitez toute
exposition à la lumière laser émise par le lecteur de codes-barres. Ne fixez
pas le faisceau des yeux.
ATTENTION : L'utilisation de commandes ou de réglages ou l'exécution
de procédures autres que celles spécifiées ici peuvent entraîner une
exposition dangereuse.

Réglementation relative à
la pile de la bibliothèque

Quantum Scalar 50 User’s Guide

ATTENTION : Ce produit comporte une batterie au lithium. La mémoire
RAM non-volatile, Dallas Semiconductor DS1743-100, comporte une pile
au lithium. Le lithium peut être considéré comme un matériau

244

Appendix F Regulatory Statements

dangereux. Mettez cette batterie au rebut conformément aux lois locales,
nationales et fédérales.

Italiano
Dichiarazione FCC

Questa apparecchiatura è stata provata e trovata conforme ai limiti per i
dispositivi digitali di Classe A, relativi alla Parte 15 delle norme FCC.
Questi limiti sono concepiti per garantire un livello ragionevole di
protezione da interferenze dannose quando l'apparecchiatura viene
azionata in un ambiente commerciale. Questa apparecchiatura genera,
utilizza e può irradiare energia a radiofrequenza e, se non installata e
utilizzata secondo il manuale di istruzioni, potrebbe causare interferenze
dannose alle comunicazioni radio.
Eventuali cambiamenti o modifiche apportati a questa apparecchiatura
potrebbero invalidare il diritto dell'utente ad utilizzare questa
apparecchiatura.
Il funzionamento dell'apparecchiatura in una zona residenziale potrebbe
causare interferenze, nel qual caso l'utente dovrà a proprie spese
prendere i dovuti provvedimenti per eliminare le interferenze.
Questo dispositivo è conforme alla Parte 15 delle norme FCC. Il
funzionamento è soggetto alle seguenti condizioni:
1 Questo dispositivo non può causare interferenze dannose e
2 Questo dispositivo deve accettare eventuali interferenze ricevute,
incluse le interferenze causate da funzionamento indesiderato.

Dichiarazione per Taiwan


	

 
  
!" #$%&'()*+
,-.

Quantum Scalar 50 User’s Guide

245

Appendix F Regulatory Statements

Industry Canada (apparati
digitali)

Riferimento: Interference-Causing Equipment Standard, ICES-003, 2.
edizione
Questo dispositivo digitale di Classe A è conforme a tutti i requisiti dei
regolamenti canadesi per apparecchiature che causano interferenze.

Avvertenza CISPR-22!

Questo è un prodotto di Classe A. In un ambiente domestico questo
prodotto potrebbe causare interferenze radio; in tal caso l'utente dovrà
adottare tutti i dovuti provvedimenti.

Avviso esclusivamente
per Stati Uniti e Canada

Se il prodotto viene spedito negli Stati Uniti, utilizzare il cavo di
alimentazione elencato UL, specificato di seguito per il funzionamento a
100-120 V. Se il prodotto viene spedito in Canada, utilizzare il cavo di
alimentazione certificato CSA, specificato di seguito per il funzionamento
a 100-120 V.
Cappuccio della spinaLama parallela con perno di terra (configurazione
NEMA 5-15P)

Dichiarazione sui
dispositivi laser

Cavo:

Tipo: SJT, tre fili da 16 AWG (1,5 mm2) o
18 AWG (1,0 mm2)

Lunghezza

Massima di 15 piedi (4,5 m)

Portata

Minima di 10 A, 125 V

ATTENZIONE: Con tutti i pannelli e le custodie in posizione, questo
prodotto è classificato come prodotto laser di Classe I. Lo scanner per
codici a barre all'interno del prodotto è invece un dispositivo laser di
Classe II. Evitare l'esposizione ai raggi laser emessi dallo scanner per
codici a barre. Non guardare fisso nel fascio di luce.
ATTENZIONE: L'utilizzo di comandi, regolazioni o procedure diversi da
quelli specificati in questa sede potrebbe causare livelli di esposizione
pericolosi.

Quantum Scalar 50 User’s Guide

246

Appendix F Regulatory Statements

Dichiarazione sulla
batteria della libreria

ATTENZIONE: Questo prodotto contiene una batteria al litio. La RAM
non volatile, di tipo Dallas Semiconductor DS1743-100, contiene una
batteria al litio. Il litio potrebbe essere considerato un materiale
pericoloso. Smaltire la batteria secondo quanto previsto dalle leggi locali,
regionali e nazionali.

Svenska
FCC-meddelande

Utrustningen har testats och befunnits uppfylla gränserna för en klass A
digital enhet i enlighet med del 15 i FCC-reglerna. Gränserna är
utformade att tillhandahålla rimligt skydd mot störningar när
utrustningen används i en kommersiell miljö. Utrustningen alstrar,
använder och kan utstråla radiofrekvent energi och kan, om den ej
installeras och används i enlighet med instruktionshandboken, orsaka
störningar i radiokommunikation.
Eventuella ändringar eller modifikationer av utrustningen kan
ogiltigförklara användarens rätt att använda utrustningen.
Användning av utrustningen i bostadsområden kan orsaka störningar
och i sådana fall måste användaren bekosta de åtgärder som krävs för att
åtgärda störningarna.
Enheten uppfyller del 15 i FCC-reglerna. Användningen underkastas
följande villkor:
1 Enheten får inte orsaka störningar och
2 enheten måste tåla mottagna störningar, inklusive störningar som
kan orsaka oönskad funktion.

Quantum Scalar 50 User’s Guide

247

Appendix F Regulatory Statements

Meddelande för Taiwan


	

 
  
!" #$%&'()*+
,-.

Kanada (digital
utrustning)

Hänvisning: Standard för störningsalstrande utrustning, ICES-003, utgåva 2

CISPR-22 Varning!

Detta är en klass A produkt. I en hemmiljö kan denna produkt orsaka
radiostörningar, i vilket fall det kan krävas att användaren vidtar
lämpliga åtgärder.

Meddelande för USA och
KANADA enbart

Om utrustningen levereras i USA, använd den UL-listade nätsladden
som specificeras nedan för användning med 100-120 V. Om utrustningen
levereras i Kanada, använd den CSA-certifierade nätsladden som
specificeras nedan för användning med 100-120 V.

Lasermeddelande

Quantum Scalar 50 User’s Guide

Denna klass A för digital utrustning uppfyller alla krav i de kanadensiska
föreskrifterna för störningsalstrande utrustning.

Kontaktkåpa

Parallellt blad med jordstift
(NEMA 5-15P-konfiguration)

Sladd

Typ: SJT, tre 1,5 mm2 (16 AWG) eller
1,0 mm2 (18 AWG) ledare

Längd

Maximalt 15 fot (4,5 m)

Märkvärde

Minimalt 10 A, 125 V

FÖRSIKTIGHET: Med alla paneler och luckor på plats klassificeras
denna produkt som en laserprodukt klass 1. Streckkodsläsaren inuti
produkten är klassificerad som en laserprodukt klass II. Undvik kontakt
med streckkodsläsarens laserstråle. Titta inte in i strålen.
248

Appendix F Regulatory Statements

FÖRSIKTIGHET: Användning av kontroller, justeringar eller utförande
av rutiner andra än de som anges i detta dokument kan leda till farlig
exponering för strålning.

Meddelande om
biblioteksbatteri

FÖRSIKTIGHET: Produkten innehåller ett litiumbatteri. Det ickeflyktiga RAM-minnet, Dallas halvledare DS1743-100, innehåller ett
litiumbatteri. Litium anses som riskavfall. Kasta batteriet i enlighet med
lokala och nationella lagar.

Simplified Chinese
FCC

1
2


	

 
  
!" #$%&'()*+
,-.

Quantum Scalar 50 User’s Guide

249

Appendix F Regulatory Statements

CISPR-22

mp

Quantum Scalar 50 User’s Guide

250

Appendix F Regulatory Statements

Traditional Chinese
FCC

1
2


	

 
  
!" #$%&'()*+
,-.

Quantum Scalar 50 User’s Guide

251

Appendix F Regulatory Statements

CISPR-22

Quantum Scalar 50 User’s Guide

252

Appendix F Regulatory Statements

Japanese
FCC

1
2

Quantum Scalar 50 User’s Guide

253

Appendix F Regulatory Statements


	

 
  
!" #$%&'()*+
,-.

Industry Canada

CISPR-22

Quantum Scalar 50 User’s Guide

254

Appendix F Regulatory Statements

Korean
FCC

Quantum Scalar 50 User’s Guide

255

Appendix F Regulatory Statements

1
2


	

 
  
!" #$%&'()*+
,-.

CISPR-22

Quantum Scalar 50 User’s Guide

256

Appendix F Regulatory Statements

Class 1

Disposal of Electrical and Electronic Equipment
This symbol on the product or on its packaging
indicates that this product should not be disposed
of with your other waste. Instead, it should be
handed over to a designated collection point for
the recycling of electrical and electronic
equipment. The separate collection and recycling
of your waste equipment at the time of disposal
will help to conserve natural resources and ensure
that it is recycled in a manner that protects human health and the
environment. For more information about where you can drop off
your waste equipment for recycling, please visit our website at:
http://qcare.quantum.com or contact your local government
authority, your household waste disposal service or the business
from which you purchased the product.

Quantum Scalar 50 User’s Guide

257

Appendix F Regulatory Statements

Declaration of Conformity

Quantum Scalar 50 User’s Guide

258

Glossary

B

back panel The panel at the back of the library that contains

theconnectors for attaching external cabling to the library.

bar code label The identification label on cartridges.
bar code scanner A laser device that is mounted on the robotic hand and

reads the cartridge bar code labels.

C

calibration The software measurements and configuration required for

successful operation of the library.

F

Fibre Channel Fibre Channel interface. This is a interface type used in

native Fibre Channel tape drives.

FCC Class A Standard established by the U.S. Federal Communications

Commission governing electromagnetic emissions.

FSE

Field service engineer

G

GUI

Graphical user interface. The browser based remote management
system use to configure and control the Scalar 50 libraries.

H

host computer The computer that issues SCSI commands to control the

library hand.

Quantum Scalar 50 User’s Guide

259

Glossary

I

ISCI

iSCSI is an IP-based standard for linking data storage devices
over a network and transferring data by carrying SCSI
commands over IP networks.

M

MTBF

Mean Time Between Failures

MTTR

Mean Time To Repair

N

NVRAM Nonvolatile random access memory

O

off-line Library is offline and not able to communicate with a host.
on-line Ready for communications with a host
OCP

Operator control panel.

pick

The act of removing a cartridge from one location in preparation
for placing it in another location.

place

The act of placing a cartridge in a location after it has been picked
from another location.

PROM

Programmable read-only memory

R

RAM

Random access memory

S

SCSI

Small Computer System Interface. A communications standard
for attaching peripheral equipment to small computers.

T

tape drive The mechanism that reads data from, and writes data to, a

P

tape.

U

Quantum Scalar 50 User’s Guide

UL

Underwriters Laboratories

260

Index

OCP 51

A

cable, SCSI, length 181

auto clean 53

cabling routing for the Scalar 50 19
capacity on demand 13, 102
cartridges
handling 182–183

B

inspecting for damage 183–185

back panel 12
CPCI card cage 11
power supplies 11
system controller board 11
tape drives 12
backup
configuration files 130
barcode label
labeling LTO cartridges 27
browser, internet 64
BSMI (see Taiwan)

cleaning cartridges 28
COD 102
component test
OCP 59
configuration files
backup 130
factory 130
factory defaults 130
restore 130
restoring 130
saving 130
configure slots 53
CPCI card cage 11

C
cabinet setup

Quantum Scalar 50 User’s Guide

creating a library partition 105

D
date and time
configuration 99
date and time setup
OCP 56
deleting a library partition 108
DHCP
enable from OCP 56
diagnostics
OCP 57
disaster recovery 123
displayed frames 68
DLT-S4
performance 5
DLTSage secure tape
best practices 122
tape migration 122
DLTSage tape security 113
drive firmware
uploading 131
drive operations
OCP 49

261

Index

pwr on/off 50
reset 50
drives page 83

class A regulatory statement 236

G

Java plug-in 64

getting started 18
guardian xxii

K

E
editing a partition 107
emergency
access 213
ESD precautions 23
event log 72
viewing 73
event logs
OCP 43

key users 88

H

create 88
creating 88

hardware information

removing 89

OCP 42

updating key user password 90

hardware status 71
health test 127
home screen 37
HP LTO-3
performance 6
HP LTO-4
performance 7

F

L
library
back panel 12
capacity on demand 102
features 8–??

fa log file 133
factory defulats
configuration files 130
failure analysis file 133
Fibre Channel
ocp setup 52
find page 78
barcode 79
find media ID 79
select map 80
find tapel
OCP 47
Firefox 64

front panel 8

I

relocating 187

identification 86
info screen
OCP 40
installing
tape cartridges 21
internet browsers, supported 64
inventory page 82
IP address
set from OCP 56
iSCSI bridge
TC2201 92

frames, displayed 68
front panel 8

emergency 213
library doors
open 22
library emulation 53
library firmware
uploading 130
library operations
OCP 45
online/offline 46
park for shipping 47
release magazines 46

J
Japan
262

setup 101
library access

library partitioning
cabinets 106
configured slots 107

Quantum Scalar 50 User’s Guide

Index

fields 95

creating 105
deleting 108

network information 93

drives 106

network setup

editing 107

OCP 55

security 54
offline 46
online 46
online/offline
from remote management pages
126

emulate P-Series 106
emulate Scalar 50 106
enable autoclean 106
enable barcode swap 106
load ports 106

from the OCP 37

O

open library doors 22

OCP

magazines 106

buttons 38

partition name 106

components 38

scsi logical unit (LUN) 106

home screen 37

Library setup
emulation 53
library setup
configure slots 53
load port configuration 60
logs 131
fa log 133

operating problems 168
operations
accessing 77, 104
drives 83
find 78

info screen 40

inventory 82

operations screen 45
overview 37–38
problems 166
OCP diagnostics screen 57
component tests 59

move page 80
operations screen
OCP 45
overview information
OCP 41

subsystem tests 58
system-level tests 58
OCP info screen
event logs 43

M

P

hardware information 42
magazines
release 46
removing 22
maintenance 129
mixed media 13

overview information 41

park for shipping 47

statistics information 43

partition setup

OCP LED status 171

auto clean 53

OCP operations screen

barcode swap 53

drive operations 49

move page 80

find tape 47

move tape

library operations 45

OCP 48
Mozilla Suite 64

move tape 48
scan inventory 50
OCP setup screen 50
cabinet setup 51

N
network configuration

Quantum Scalar 50 User’s Guide

date and time setup 56
network setup 55
partition setup 52

OCP 52
partitions
native Fibre Channel interface
103
requirements 103
setup 102
power supplies 11
power supply LEDs 175
powering off 37
problems
OCP 166
263

Index

operating 168

scb 11

setup wizard 108

robotics 166

SCSI

shipping

start-up 165

cable length 181

park robot 47

SCSI IDs 91

SNMP traps 95

SCSI II specification xx

start-up
problems 165

secure key 113

Q
Quantum LTO-3
performance 6
Quantum LTO-4 HH
performance 7

assign secure key to cartridge
117

statistics 73
statistics information

backup secure key file 120
create secure key name/secure
key pair 118

OCP 43
status 70
event log 72

delete secure key name 119

hardware 71

enable/disable secure key for
drives 116

overview 70
statistics 73

R

protection mode for cartridges
115

storage care guardian xxii

reference

select secure key for library 117

subsystem tests

web pages 134
release magazines 46

secure key migration 122

relocating

secure tape

library 187
removing magazines 22

best practices 122
remove 89

restore

update 90

configuration files 130
park for shipping 47
robotics problems 166

setup

scan inventory
OCP 50
SCB
LEDs 171

264

health tests 127

T

accessing 85

identification 86

cable routing 19

OCP 58
system tests 128

OCP 54

events 95

Scalar 50

LEDs 171
system -level tests

security

date and time 99

S

system controller board 11

secure users

reset tape drive 50

robot

OCP 58

upload secure key file 121

Taiwan
class A regulatory statement 236
tape cartridge

library 101

barcode labeling

network 93
partitions 102

LTO 27
loading 20

SCSI/Fibre 91

LTO

setup wizard 108

barcode labeling 27
SDLT

TC2201 bridge 92
user information 87

inserting 26

Quantum Scalar 50 User’s Guide

Index

write-protect switch 25
tape cartridge migration scenario
123
tape cartridge types
LTO 26
SDLT 24
tape cartridges
handling 182–183

U
uploading
drive firmware 131
uploading library firmware 130
user information 87
utilities
library 125

inspecting for damage 183–185

logs 131

installing 21

maintenance 129

key migration 122

tasks 133

tape drive
details 72
reset 50
SCSI IDs 91
tape drive LEDs 176
tape drives 12

V
VCCI (see Japan)

FC bridge 92
Fibre Channel OCP setup 52
iSCSI bridge 92
tape magazines
removing 22
tasks 133
TC2201 92
testing the email system 97
tests
system 128

W
Web pages
accessing 67
menu items 64
web pages
using 67
write-protect switch 25

traps
SNMP 95
troubleshooting 164–169
OCP 166
operating 168
robotics 166
start-up 165
turning the library off 37

Quantum Scalar 50 User’s Guide

265

Index

266

Quantum Scalar 50 User’s Guide



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : No
Tagged PDF                      : Yes
Page Mode                       : UseOutlines
XMP Toolkit                     : Adobe XMP Core 4.0-c316 44.253921, Sun Oct 01 2006 17:14:39
Format                          : application/pdf
Description                     : Quantum On-line Documentation Series
Title                           : Quantum Scalar 50 User’s Guide
Creator                         : Technical Publications (JMN)
Producer                        : Acrobat Distiller 8.1.0 (Windows)
Creator Tool                    : FrameMaker 8.0
Modify Date                     : 2008:07:09 08:58:04-07:00
Create Date                     : 2008:07:09 08:41:09Z
Metadata Date                   : 2008:07:09 08:58:04-07:00
Document ID                     : uuid:f9552520-17a3-4b33-8dbe-d0e34802f326
Instance ID                     : uuid:16efc4a6-4a3c-4407-abba-426a8c67a245
Page Count                      : 290
Page Layout                     : SinglePage
Subject                         : Quantum On-line Documentation Series
Author                          : Technical Publications (JMN)
Warning                         : [Minor] Ignored duplicate Info dictionary
EXIF Metadata provided by EXIF.tools

Navigation menu