Release Notes
Product

Scalar® i6000, Firmware Version i12.2.2

Firmware Version

710Q.GS11200

Operating Systems
(Standalone LMC Client)

Microsoft Windows
Ubuntu x86/ia64
Red Hat Linux x86/ia64

Supported Web Browsers
(Java GUI)

Firefox
Internet Explorer versions 7 and higher

Supported Web Browsers
(WebGUI)

Firefox
Chrome

Required Java Runtime
Environment (JRE)

JRE version 6 and higher

Date

June 2015

Contents
Purpose of This Release . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
New Features and Enhancements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
General Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Security Scanners . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Compatibility and Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Resolved Issues . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Known Issues . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Documentation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Contacting Quantum . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

© 2015 Quantum Corporation. All rights reserved.

6-66883-41 Rev A, June 2015

Quantum, the Quantum logo, DLT, DLTtape, the DLTtape logo, SuperLoader, Scalar, StorNext, and DXi are registered
trademarks of Quantum Corporation, registered in the U.S. and other countries. All other trademarks are the property of their
respective companies. Specifications are subject to change without notice.

Quantum Scalar i6000 Release Notes
6-66883-41 Rev A
June 2015

Purpose of This Release
The Scalar i6K i12.2.2 release details bug fixes described in the Resolved Issues
section.
Visit http://www.quantum.com for additional information about the Scalar
i6000 and prior releases.

New Features and Enhancements
This release contains no new features or enhancements.

General Information
• The standalone LMC client is not provided by default. Contact Quantum
Service for details.
• JRE is not required with the standalone LMC client.
• If media is encrypted on an IBM drive using Library Managed Encryption
(LME), the library will initially report the media as being unencrypted when
it is actually encrypted. The encryption status of the media will be properly
reported once the media is re-mounted in the drive.
• To help maintain system integrity and for marketing purposes, Quantum
regularly collects system information through automatic emails. These
emails contain configuration and status information only, and do not
contain any customer data stored on the system. To disable this function:
1 Log on to your library.
2 Go to Setup > System Setting > Physical Library.
3 In the Send Usage Statistics area, select the Disable radio button.
4 Click OK.
• The Web client places a cookie on the user’s computer to provide the last
user’s credentials upon login. The cookie only collects the user’s credentials
to facilitate login, and does not collect any other user data.

2

Purpose of This Release

Quantum Scalar i6000 Release Notes
6-66883-41 Rev A
June 2015

Security Scanners
Quantum runs the following Security scanners against the library:
• BeyondTrust Retina Network Security Scanner version 5.18.3.2656.
• No critical issues were reported

Compatibility and Support
Encryption Key
Management Drive
Support
HP
LTO-4

IBM
LTO-4

HP
LTO-5

IBM
LTO-5

HP
LTO-6

IBM
LTO-6

Application Managed
Encryption

Supported

Supported

Supported

Supported

Supported

Supported

Q-EKM

Not
Supported

Requires
EKM
License

Not
Supported

Requires
EKM
License

Not
Supported

Requires
EKM
License

SKM

Requires
EKM
License

Not
Supported

Requires
EKM
License

Requires
EKM
License

Requires
EKM
License

Requires
EKM
License

KMIP Key Manager1

Requires
EKM
License

Not
Supported

Requires
EKM
License

Requires
EKM
License

Requires
EKM
License

Requires
EKM
License

Encryption Option

1

- Only SafeNet and Thales encryption key servers are supported KMIP configurations

Security Scanners

3

Quantum Scalar i6000 Release Notes
6-66883-41 Rev A
June 2015

Firmware Compatibility
Matrix

The following table shows information on drive and auxiliary firmware
compatibility with this release of Scalar i6000. This information is current as of
this product release. For the most up-to-date information on the latest qualified
firmware, please visit: http://www.quantum.com.

Release: i12.2.2
Library Firmware: 710Q.GS11200
Library Management Console (LMC) Remote Client: 710G.GH10600

Drive Types

Firmware Version2

IBM LTO-1 (SCSI)

5AU1

IBM LTO-1 (FC)

5AU1

IBM LTO-2 (SCSI)

A4N0

IBM LTO-2 (FC)

A4N0

IBM LTO-3 (FC) 2 Gb

93GM

IBM LTO-3 (FC) 4 Gb

93GM

IBM LTO-4 (FC) 4 Gb

C7QH

IBM LTO-5 (FC) 8 Gb

E6Q6

IBM LTO-6 (FC) 8 Gb

E6R6

HP LTO-3 (FC) 2 Gb

L67Z

HP LTO-3 (FC) 4 Gb

M69Z

HP LTO-4 (FC) 4 Gb

H64Z

HP LTO-5 (FC) 8 Gb

I6GZ

HP LTO-6 (FC) 8 Gb

J55Z

1. For information about installing the LMC remote client, contact Quantum Support.
2. Check with Quantum Support for the latest firmware.
3. Logical serial number addressing (drive spoofing) is not supported.

Backup Software
Compatibility

4

To view a list of backup software packages that have been tested for
interoperability with the Scalar i6000, refer to the Quantum Software
Compatibility Guide at http://www.quantum.com/swcompguide.aspx.

Compatibility and Support

Quantum Scalar i6000 Release Notes
6-66883-41 Rev A
June 2015

Resolved Issues
This release of Scalar i6000 firmware resolved the following issues:
Change
Request
Number

Service
Request
Number

56096

3534826

Description

Resolution

An external application passing a value of
0 will cause internal library
communications between the RCU and
MCB to fail.

Fixed.

56104

After enabling IPv6 and DHCPIPv6 on the
library, a reboot would fail to get a DHCP IP
address.

Fixed.

56007

Using the stateless auto-configuration IPv6
may not allow a connection to the library’s
LMC, even with IPv6 enabled.

Fixed.

Known Issues
This release of i6000 i12.2.2 firmware has the following known issues.
Change
Request
Number

Service
Request
Number

Description

Workaround

42325

If a SafeNet key server(s) in a cluster is not
reachable during normal key requests,
encryption keys issued by other key servers
in the cluster will not automatically
replicate to the unreachable server(s)
afterwards.

Users need to sync the key server
cluster manually.

43012

When the library has an issue importing
encryption keys, an error message
erroneously informs users that there was a
communication issue with the key server.

Verify that communication to the key
server is operational (perform Path
Diagnostics).
If communication with the key server
is not impacted, the issue is that the
keys cannot be imported due to
being wrapped with a certificate
(public key) that does not match the
server’s private key.

Resolved Issues

5

Quantum Scalar i6000 Release Notes
6-66883-41 Rev A
June 2015

Change
Request
Number

Service
Request
Number

Description

Workaround

In some instances, during a drive firmware
update and associated drive reboot, a
diagnostic ticket reporting the drive has
been removed may be generated.

The drive should come back online
after the firmware update is
complete and the diagnostic ticket
will auto close. If not, follow the
directions on the diagnostic ticket to
troubleshoot.

MICA should only inform of multi-initiator
conflicts, not just multi-initiator operation
without reservations.

If multi-initiator operation without
reservations is being reported, you
can filter the diagnostic tickets.
From the GUI, configure the library to
enable diagnostic ticket filtering
(Setup > Notifications > Tickets
Filter).

53329

EEB attached IBM LTO-5 and LTO-6 drives
upgraded to latest drive firmware may
come up in the library in passive mode.

Reboot each drive individually. If that
doesn’t fix the issue, reboot the
library.

51994

When a drive sled is added to a partition it
may not appear in RES data.

Make sure that the robot(s) is
enabled and initialized before
physically adding the drive to the
library.

54091

During a backup, if the drive loses both FC
connections, failover will occur but the
media will not be moved to home slot.

To get the media to return to home
slot from Net back Up (NBU):
1 Select Devices > Robot.
2 Right click.
3 Select Change.
4 Browse to select robot device.
5 Click OK.
6 Click OK.
7 Click OK. Media is then put in it’s
home slot.

51702

During IVT, data pertaining to the driveside magazines in the right parking
module is not included in the report.

Make sure that the calibration targets
are located in the correct column and
row.
If calibration targets cannot be in
their proper position because of drive
location, you can move the drives to
different positions in the drive sled.

43149

50514,
50591

6

1647282,
1647440

Known Issues

Quantum Scalar i6000 Release Notes
6-66883-41 Rev A
June 2015

Change
Request
Number

Service
Request
Number

Description

Workaround

54202

If you disconnect the cable from a control
path drive that is connect to a host HBA,
the library will lose connectivity to the
robot.

1 Update path to robot.
2 run library audit
checklabel = barcode.
3 Media will now return to its home
slot.
4 Users are now able to run
simultaneous backups to both
drives without repairing FC
connection on Host HBA.

54220

If the control path drive fails over during
an import, any media in the picker will not
be discovered.

1 Run checkin libvolume search=yes
to pickup missing media
2 Then rerun the checkin libvolume
search=bulk to import remaining
media in I/E.

54580

A Series 3 control module may show the
presence of two CMBs even though there
is only one.

There is no negative effect to library
functionality. The second CMB listed
is actually the MCB.

If the email addresses in the Contact tab
of the Notifications dialog and the Email
Notifications dialog are the same, an
email will ‘bounce’ (ie, undeliverable) and
fail to be delivered.

Check:
Setup > Notifications > System
Setup (Email Address field), and
Setup > Email Configuration
(Sender Address field)

54852

During a change to the internal IP of the
library the GUI can hang if you wait too
long to respond to dialog prompts.

Respond to the dialog prompts in a
timely manner. If you do wait too
long, reboot the library.

55202

When upgrading from i11.x to i12.x, all
ticket suppression filters will not be
restored. Restoring a configuration back to
i11.3 will also not restore the filters.

Before the upgrade, note which
filters you have set and then reset
them after the upgrade is complete.

55216

In libraries larger than 8 frames,
a geo-addressing issue may cause
diagnostic tickets related to CMBs and
HDCs to be generated in error.

Reboot the library.

55492

When upgrading from i11.3 to i12.2.1, the
partition is not mapped or listed in the
Access Group Configuration.

1
2
3
4
5
6
7
8

54630

Known Issues

3948014

Go to Setup > SNW Wizard.
Click Next.
Select Host Access radio button.
Click Next.
Select Host Access Configuration.
Click Next.
Select Group.
Expand Tree.

7

Quantum Scalar i6000 Release Notes
6-66883-41 Rev A
June 2015

Change
Request
Number
52434

Service
Request
Number

Description

3382082,
3399088

If a open door is detected, the library may
report the wrong door as open.

Workaround
• Check to ensure that all doors are
closed properly.
• Check the lance (small metal piece
in door lock) to see if it is
damaged. Repair if possible and
close door.

54884
52884

3522766

During a library snapshot, the HDC may go
offline.

Reboot the library.

The following Nessus scan result may be
generated:

An i6000 library does not use
Apache. This is a false positive.

Nessus was unable to crash the web
server, so this might be a false positive.

Documentation
The following documents are currently available for the Scalar i6000.

8

Document Number

Document Title

6-66879-xx

Scalar i6000 User’s Guide

6-66882-xx

Scalar i6000 Planning Guide

6-01847-xx

Quantum Encryption Key Manager User’s Guide

6-01884-xx

Quantum Encryption Key Manager Release Notes

6-66532-xx

Scalar Key Manager Quick Start Guide

6-66531-xx

Scalar Key Manager User’s Guide

6-66572-xx

Scalar Key Manager Safety Information by IBM

6-66535-xx

Scalar Key Manager Open Source License
Agreement

Documentation

Quantum Scalar i6000 Release Notes
6-66883-41 Rev A
June 2015

Contacting Quantum
More information about this product is available on the Service and Support
website at www.quantum.com/support. The Service and Support Website
contains a collection of information, including answers to frequently asked
questions (FAQs). You can also access software, firmware, and drivers through
this site.
For further assistance, or if training is desired, contact Quantum:
Quantum Technical Assistance
Center in the USA:

+1 800-284-5101

For additional contact information:

www.quantum.com/support

To open a Service Request:

www.quantum.com/osr

For the most updated information on Quantum Global Services, please visit:
www.quantum.com/support

Contacting Quantum

9

Quantum Scalar i6000 Release Notes
6-66883-41 Rev A
June 2015

10

Contacting Quantum



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : Yes
Author                          : Quantum Corp. Technical Publications (si)
Create Date                     : 2000:11:30 11:51:23Z
Modify Date                     : 2015:06:24 09:09:41-06:00
Subject                         : Quantum Online Documentation Series
Language                        : en
Tagged PDF                      : Yes
XMP Toolkit                     : Adobe XMP Core 5.4-c005 78.150055, 2012/11/19-18:45:32
Format                          : application/pdf
Description                     : Quantum Online Documentation Series
Title                           : Scalar i6000 i10.0.3 Release Notes
Creator                         : Quantum Corp. Technical Publications (si)
Producer                        : Acrobat Distiller 11.0 (Windows)
Creator Tool                    : FrameMaker 12.0.4
Metadata Date                   : 2015:06:24 09:09:41-06:00
Document ID                     : uuid:bcf6b1f8-dfae-4450-9f55-68c8642dfd00
Instance ID                     : uuid:3ea971d5-dcfc-414e-b4fe-79abbf66294f
Page Mode                       : UseOutlines
Page Count                      : 10
EXIF Metadata provided by EXIF.tools

Navigation menu