Quantum Scalar i6000
Release Notes
Product Scalar® i6000, Firmware Version i12.2.2
Firmware Version 710Q.GS11200
Operating Systems
(Standalone LMC Client)
Microsoft Windows
Ubuntu x86/ia64
Red Hat Linux x86/ia64
Supported Web Browsers
(Java GUI)
Firefox
Internet Explorer versions 7 and higher
Supported Web Browsers
(WebGUI)
Firefox
Chrome
Required Java Runtime
Environment (JRE)
JRE version 6 and higher
Date June 2015
Contents
Purpose of This Release . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
New Features and Enhancements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
General Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Security Scanners . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Compatibility and Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Resolved Issues . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Known Issues . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Documentation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Contacting Quantum . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Quantum Scalar i6000 Release Notes
6-66883-41 Rev A
June 2015
2 Purpose of This Release
Purpose of This Release
The Scalar i6K i12.2.2 release details bug fixes described in the Resolved Issues
section.
Visit http://www.quantum.com for additional information about the Scalar
i6000 and prior releases.
New Features and Enhancements
This release contains no new features or enhancements.
General Information
The standalone LMC client is not provided by default. Contact Quantum
Service for details.
JRE is not required with the standalone LMC client.
If media is encrypted on an IBM drive using Library Managed Encryption
(LME), the library will initially report the media as being unencrypted when
it is actually encrypted. The encryption status of the media will be properly
reported once the media is re-mounted in the drive.
To help maintain system integrity and for marketing purposes, Quantum
regularly collects system information through automatic emails. These
emails contain configuration and status information only, and do not
contain any customer data stored on the system. To disable this function:
1Log on to your library.
2Go to Setup > System Setting > Physical Library.
3In the Send Usage Statistics area, select the Disable radio button.
4Click OK.
The Web client places a cookie on the user’s computer to provide the last
user’s credentials upon login. The cookie only collects the user’s credentials
to facilitate login, and does not collect any other user data.
Quantum Scalar i6000 Release Notes
6-66883-41 Rev A
June 2015
Security Scanners 3
Security Scanners
Quantum runs the following Security scanners against the library:
BeyondTrust Retina Network Security Scanner version 5.18.3.2656.
No critical issues were reported
Compatibility and Support
Encryption Key
Management Drive
Support
Encryption Option
HP
LTO-4
IBM
LTO-4
HP
LTO-5
IBM
LTO-5
HP
LTO-6
IBM
LTO-6
Application Managed
Encryption
Supported Supported Supported Supported Supported Supported
Q-EKM Not
Supported
Requires
EKM
License
Not
Supported
Requires
EKM
License
Not
Supported
Requires
EKM
License
SKM Requires
EKM
License
Not
Supported
Requires
EKM
License
Requires
EKM
License
Requires
EKM
License
Requires
EKM
License
KMIP Key Manager1Requires
EKM
License
Not
Supported
Requires
EKM
License
Requires
EKM
License
Requires
EKM
License
Requires
EKM
License
1 - Only SafeNet and Thales encryption key servers are supported KMIP configurations
Quantum Scalar i6000 Release Notes
6-66883-41 Rev A
June 2015
4 Compatibility and Support
Firmware Compatibility
Matrix
The following table shows information on drive and auxiliary firmware
compatibility with this release of Scalar i6000. This information is current as of
this product release. For the most up-to-date information on the latest qualified
firmware, please visit: http://www.quantum.com.
Release: i12.2.2
Library Firmware: 710Q.GS11200
Library Management Console (LMC) Remote Client: 710G.GH10600
Drive Types Firmware Version2
IBM LTO-1 (SCSI) 5AU1
IBM LTO-1 (FC) 5AU1
IBM LTO-2 (SCSI) A4N0
IBM LTO-2 (FC) A4N0
IBM LTO-3 (FC) 2 Gb 93GM
IBM LTO-3 (FC) 4 Gb 93GM
IBM LTO-4 (FC) 4 Gb C7QH
IBM LTO-5 (FC) 8 Gb E6Q6
IBM LTO-6 (FC) 8 Gb E6R6
HP LTO-3 (FC) 2 Gb L67Z
HP LTO-3 (FC) 4 Gb M69Z
HP LTO-4 (FC) 4 Gb H64Z
HP LTO-5 (FC) 8 Gb I6GZ
HP LTO-6 (FC) 8 Gb J55Z
1. For information about installing the LMC remote client, contact Quantum Support.
2. Check with Quantum Support for the latest firmware.
3. Logical serial number addressing (drive spoofing) is not supported.
Backup Software
Compatibility
To view a list of backup software packages that have been tested for
interoperability with the Scalar i6000, refer to the Quantum Software
Compatibility Guide at http://www.quantum.com/swcompguide.aspx.
Quantum Scalar i6000 Release Notes
6-66883-41 Rev A
June 2015
Resolved Issues 5
Resolved Issues
This release of Scalar i6000 firmware resolved the following issues:
Change
Request
Number
Service
Request
Number Description Resolution
56096 3534826 An external application passing a value of
0 will cause internal library
communications between the RCU and
MCB to fail.
Fixed.
56104 After enabling IPv6 and DHCPIPv6 on the
library, a reboot would fail to get a DHCP IP
address.
Fixed.
56007 Using the stateless auto-configuration IPv6
may not allow a connection to the library’s
LMC, even with IPv6 enabled.
Fixed.
Known Issues
This release of i6000 i12.2.2 firmware has the following known issues.
Change
Request
Number
Service
Request
Number
Description Workaround
42325 If a SafeNet key server(s) in a cluster is not
reachable during normal key requests,
encryption keys issued by other key servers
in the cluster will not automatically
replicate to the unreachable server(s)
afterwards.
Users need to sync the key server
cluster manually.
43012 When the library has an issue importing
encryption keys, an error message
erroneously informs users that there was a
communication issue with the key server.
Verify that communication to the key
server is operational (perform Path
Diagnostics).
If communication with the key server
is not impacted, the issue is that the
keys cannot be imported due to
being wrapped with a certificate
(public key) that does not match the
server’s private key.
Quantum Scalar i6000 Release Notes
6-66883-41 Rev A
June 2015
6 Known Issues
43149 In some instances, during a drive firmware
update and associated drive reboot, a
diagnostic ticket reporting the drive has
been removed may be generated.
The drive should come back online
after the firmware update is
complete and the diagnostic ticket
will auto close. If not, follow the
directions on the diagnostic ticket to
troubleshoot.
50514,
50591
1647282,
1647440
MICA should only inform of multi-initiator
conflicts, not just multi-initiator operation
without reservations.
If multi-initiator operation without
reservations is being reported, you
can filter the diagnostic tickets.
From the GUI, configure the library to
enable diagnostic ticket filtering
(Setup > Notifications > Tickets
Filter).
53329 EEB attached IBM LTO-5 and LTO-6 drives
upgraded to latest drive firmware may
come up in the library in passive mode.
Reboot each drive individually. If that
doesn’t fix the issue, reboot the
library.
51994 When a drive sled is added to a partition it
may not appear in RES data.
Make sure that the robot(s) is
enabled and initialized before
physically adding the drive to the
library.
54091 During a backup, if the drive loses both FC
connections, failover will occur but the
media will not be moved to home slot.
To get the media to return to home
slot from Net back Up (NBU):
1Select Devices > Robot.
2Right click.
3Select Change.
4Browse to select robot device.
5Click OK.
6Click OK.
7Click OK. Media is then put in it’s
home slot.
51702 During IVT, data pertaining to the drive-
side magazines in the right parking
module is not included in the report.
Make sure that the calibration targets
are located in the correct column and
row.
If calibration targets cannot be in
their proper position because of drive
location, you can move the drives to
different positions in the drive sled.
Change
Request
Number
Service
Request
Number
Description Workaround
Quantum Scalar i6000 Release Notes
6-66883-41 Rev A
June 2015
Known Issues 7
54202 If you disconnect the cable from a control
path drive that is connect to a host HBA,
the library will lose connectivity to the
robot.
1Update path to robot.
2run library audit
checklabel = barcode.
3Media will now return to its home
slot.
4Users are now able to run
simultaneous backups to both
drives without repairing FC
connection on Host HBA.
54220 If the control path drive fails over during
an import, any media in the picker will not
be discovered.
1Run checkin libvolume search=yes
to pickup missing media
2Then rerun the checkin libvolume
search=bulk to import remaining
media in I/E.
54580 A Series 3 control module may show the
presence of two CMBs even though there
is only one.
There is no negative effect to library
functionality. The second CMB listed
is actually the MCB.
54630 3948014 If the email addresses in the Contact tab
of the Notifications dialog and the Email
Notifications dialog are the same, an
email will ‘bounce’ (ie, undeliverable) and
fail to be delivered.
Check:
Setup > Notifications > System
Setup (Email Address field), and
Setup > Email Configuration
(Sender Address field)
54852 During a change to the internal IP of the
library the GUI can hang if you wait too
long to respond to dialog prompts.
Respond to the dialog prompts in a
timely manner. If you do wait too
long, reboot the library.
55202 When upgrading from i11.x to i12.x, all
ticket suppression filters will not be
restored. Restoring a configuration back to
i11.3 will also not restore the filters.
Before the upgrade, note which
filters you have set and then reset
them after the upgrade is complete.
55216 In libraries larger than 8 frames,
a geo-addressing issue may cause
diagnostic tickets related to CMBs and
HDCs to be generated in error.
Reboot the library.
55492 When upgrading from i11.3 to i12.2.1, the
partition is not mapped or listed in the
Access Group Configuration.
1Go to Setup > SNW Wizard.
2Click Next.
3Select Host Access radio button.
4Click Next.
5Select Host Access Configuration.
6Click Next.
7Select Group.
8Expand Tree.
Change
Request
Number
Service
Request
Number
Description Workaround
Quantum Scalar i6000 Release Notes
6-66883-41 Rev A
June 2015
8 Documentation
Documentation
The following documents are currently available for the Scalar i6000.
Document Number Document Title
6-66879-xx Scalar i6000 User’s Guide
6-66882-xx Scalar i6000 Planning Guide
6-01847-xx Quantum Encryption Key Manager User’s Guide
6-01884-xx Quantum Encryption Key Manager Release Notes
6-66532-xx Scalar Key Manager Quick Start Guide
6-66531-xx Scalar Key Manager User’s Guide
6-66572-xx Scalar Key Manager Safety Information by IBM
6-66535-xx Scalar Key Manager Open Source License
Agreement
52434 3382082,
3399088
If a open door is detected, the library may
report the wrong door as open.
Check to ensure that all doors are
closed properly.
Check the lance (small metal piece
in door lock) to see if it is
damaged. Repair if possible and
close door.
54884 3522766 During a library snapshot, the HDC may go
offline.
Reboot the library.
52884 The following Nessus scan result may be
generated:
Nessus was unable to crash the web
server, so this might be a false positive.
An i6000 library does not use
Apache. This is a false positive.
Change
Request
Number
Service
Request
Number
Description Workaround
Quantum Scalar i6000 Release Notes
6-66883-41 Rev A
June 2015
Contacting Quantum 9
Contacting Quantum
More information about this product is available on the Service and Support
website at www.quantum.com/support. The Service and Support Website
contains a collection of information, including answers to frequently asked
questions (FAQs). You can also access software, firmware, and drivers through
this site.
For further assistance, or if training is desired, contact Quantum:
Quantum Technical Assistance
Center in the USA:
+1 800-284-5101
For additional contact information: www.quantum.com/support
To open a Service Request: www.quantum.com/osr
For the most updated information on Quantum Global Services, please visit:
www.quantum.com/support
Quantum Scalar i6000 Release Notes
6-66883-41 Rev A
June 2015
10 Contacting Quantum

Navigation menu