Queclink Wireless Solutions GV50LTA LTE/GPS Locator User Manual

Queclink Wireless Solutions Co.,Ltd LTE/GPS Locator

User Manual

GV50LTA Manage Tool User Guide      - 0 -     GV50LTA Manage Tool User Guide   FDD-LTE/GPS Tracker   QSZTRACGV50LTAMT0001 Version: 1.00 GV50LTA
GV50LTA Manage Tool User Guide      - 1 -  Document Title GV50LTA User Manual Version 1.00 Date 2016-12-06 Status Release Document Control ID QSZTRACGV50LTAUM0001  General Notes Queclink  offers  this  information  as  a  service  to  its  customers,  to  support  application  and engineering efforts that use the products designed by Queclink. The information provided is based upon requirements specifically provided to Queclink by the customers. Queclink has not  undertaken  any independent  search for  additional  relevant information,  including any information  that  may  be  in  the  customer’s  possession.  Furthermore,  system  validation  of this  product  designed  by  Queclink  within  a  larger  electronic  system  remains  the responsibility  of  the  customer  or  the  customer’s  system  integrator.  All  specifications supplied herein are subject to change.  Copyright This document contains proprietary technical information which is the property of Queclink. The  copying of  this  document,  distribution  to  others,  and  communication  of  the  contents thereof,  are  forbidden  without  express  authority.  Offenders  are  liable  to  the  payment  of damages.  All  rights  are  reserved  in  the  event  of  a  patent  grant  or  registration  of  a  utility model or design. All specifications supplied herein are subject to change without notice at any time.  Copyright ©  Queclink Wireless Solutions Co., Ltd. 2016  WARNING: The device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) The device may not cause harmful interference, and (2) The device must accept any interference received, including interference that may cause undesired operation. Change or modification not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. FCC RF Exposure Statement: The normal use condition for the product is at least 20cm away from the body of the user, so the user must keep a distance of at least 20cm from the product. Queclink
GV50LTA Manage Tool User Guide      - 2 -  Contents Contents ........................................................................................................................................- 2 - Table Index ....................................................................................................................................- 3 - Figure Index ...................................................................................................................................- 4 - 0. Revision History .........................................................................................................................- 5 - 1. Introduction ..............................................................................................................................- 6 - 1.1. Reference .......................................................................................................................- 6 - 1.2. Terms and Abbreviations ................................................................................................- 6 - 2. Product Overview ......................................................................................................................- 7 - 2.1. Appearance ....................................................................................................................- 7 - 2.2. Interface Definition ........................................................................................................- 7 - 2.3. LED Description ..............................................................................................................- 8 - 2.4. Power Connection ..........................................................................................................- 8 - 2.5. Ignition Detection...........................................................................................................- 9 - 2.6. Digital Output/ Input Connection ..................................................................................- 9 - 2.7. Digital Output .............................................................................................................. - 11 - 3. Getting Started ....................................................................................................................... - 13 - 3.1. Parts List ...................................................................................................................... - 13 - 3.2. GV50LTA External Cable Interface ............................................................................... - 13 - 3.3. Open the SIM Card cover ............................................................................................ - 14 - 3.4. Clos the SIM Card cover .............................................................................................. - 14 - 3.5. Install a SIM Card ......................................................................................................... - 15 - 3.6. Switch on the Backup Battery ..................................................................................... - 15 - 4. Troubleshooting and Safety Info ............................................................................................ - 16 - 4.1. Troubleshooting .......................................................................................................... - 16 - 4.2. Safety Info ................................................................................................................... - 16 -    Queclink
GV50LTA Manage Tool User Guide      - 3 -  Table Index TABLE 1: GV50LTA PROTOCOL REFERENCE .......................................................................................... - 6 - TABLE 2: TERMS AND ABBREVIATIONS ................................................................................................ - 6 - TABLE 3: DESCRIPTION OF 7 PIN CONNECTIONS .................................................................................. - 8 - TABLE 4: LED DESCRIPTION .................................................................................................................. - 8 - TABLE 5: ELECTRICAL CHARACTERISTICS OF IGNITION DETECTION ..................................................... - 9 - TABLE 6: ELECTRICAL CHARACTERISTICS OF DIGITAL OUTPUTS ......................................................... - 10 - TABLE 7: ELECTRICAL CHARACTERISTICS OF DIGITAL INPUTS ............................................................ - 10 - TABLE 8: ELECTRICAL CHARACTERISTICS AS DIGITAL OUTPUTS ......................................................... - 12 - TABLE 9: PARTS LIST ........................................................................................................................... - 13 - TABLE 10: GV50LTA USER CABLE COLOUR DEFINITION ..................................................................... - 13 -    Queclink
GV50LTA Manage Tool User Guide      - 4 -  Figure Index FIGURE 1: GV50LTA APPEARANCE ........................................................................................................ - 7 - FIGURE 2: 7PIN CONNECTOR ON THE GV50LTA ................................................................................... - 7 - FIGURE 3: TYPICAL POWER CONNECTION ............................................................................................ - 8 - FIGURE 4: TYPICAL IGNITION DETECTION............................................................................................. - 9 - FIGURE 5: AS DIGITAL OUTPUT INTERNAL DRIVE CIRCUIT ................................................................. - 10 - FIGURE 6: TYPICAL CONNECTION WITH BUZZER AS DIGITAL OUTPUT............................................... - 10 - FIGURE 7: TYPICAL DIGITAL INPUT CONNECTION .............................................................................. - 11 - FIGURE 8: DIGITAL OUTPUT INTERNAL DRIVE CIRCUIT ...................................................................... - 11 - FIGURE 9: TYPICAL CONNECTION WITH RELAY .................................................................................. - 12 -    Queclink
GV50LTA Manage Tool User Guide      - 5 -  0. Revision History Revision Date Author Description of change 1.00 2017-1-16 Rayne_Wu Initial Version                Queclink
GV50LTA Manage Tool User Guide      - 6 -  1. Introduction The GV50LTA is a powerful GPS locator designed for vehicle or asset tracking. It has superior receiver  sensitivity,  fast  TTFF  (Time  to  First  Fix)  and  supports  Dual-Band  4G-LTE  B4&B13 Band,  and  its  location can  be  monitored in  real  time  or  periodically  tracked  by  a  backend server or other specified terminals. The GV50LTA has multiple input/output interfaces that can be used for monitoring or controlling external devices. Based on the integrated @Track protocol, the GV50LTA can communicate with a backend server through the 4G-LTE network over  which  it  transfer  reports  of  emergency,  geo-fence  boundary  crossings,  low  backup battery or scheduled GPS position as well as many other useful functions. Users can also use GV50LTA  to  monitor  the  status  of  a  vehicle  and  control  the  vehicle  by  its  external  relay output.  System  Integrators  can  easily  set  up  their  tracking  systems  based  on  the full-featured @Track protocol.  1.1. Reference Table 1: GV50LTA Protocol Reference SN Document name Remark [1] GV50LTA @Track Air Interface Protocol The air protocol interface between GV50LTA and backend server.  1.2. Terms and Abbreviations Table 2: Terms and Abbreviations Abbreviation   Description AGND Analog Ground AIN Analog Input DIN Digital Input DOUT Digital Output GND Ground RXD Receive Data TXD Transmit Data   Queclink
GV50LTA Manage Tool User Guide      - 7 -  2. Product Overview  2.1. Appearance           Figure 1: GV50LTA Appearance  2.2. Interface Definition The GV50LTA has a 7 PIN interface connector. It contains the connections for power, and I/O. The sequence and description of the 7PIN connector are shown in the following figure:             Figure 2: 7PIN Connector on the GV50LTA   Queclink
GV50LTA Manage Tool User Guide      - 8 -  Table 3: Description of 7 PIN Connections Index Description Comment   1 RXD UART RXD; TTL 2 TXD UART TXD; TTL 3 VIN External DC power input, 8-32V 4 IGN Ignition input, positive trigger 5 OUT1/IN1 Digital output/ input; Open drain,150mA max 6 OUT2 Open drain, 150mA max   7 GND GND  2.3. LED Description GV50LTA has two status LEDs which are CELL LED (Blue color) and GPS LED (Green color).  CELL Device is searching CELL network.   Fast flashing Device has registered to CELL network. ON Device is in low power mode. Slow flashing GPS GPS is unfixed. OFF GPS is fixed. ON Device is in low power mode. Slow flashing Table 4: LED Description Note:   1. Fast flashing is about 500ms ON / 1sec OFF. 2. Slow flashing is about 500ms ON / 15sec OFF.  2.4. Power Connection VIN(PIN3)/GND (PIN7) are the  power  input  pins.  The input voltage range  for this device  is from 8V to 32V. The device is designed to be installed in vehicles that operate on 12V/24V vehicle without the need for external transformers.       Figure 3: Typical Power Connection DC Power GND Queclink
GV50LTA Manage Tool User Guide      - 9 -  2.5. Ignition Detection IGN (Pin4) is used for ignition detection. It is strongly recommended to connect this pin to ignition key “RUN” position as shown below. An alternative to connecting to the ignition switch is to find a non-permanent power source that is only available when the vehicle is running. For example, the power source for the FM radio. IGN signal can be configured to start transmitting information to backend server when ignition is on, and enter power saving mode when ignition is off. Table 5: Electrical Characteristics of Ignition Detection Logical State Electrical State Active 5.0V to 32V Inactive 0V to 3V or Open                    Figure 4: Typical Ignition Detection  OUT1/IN1 (PIN5) is a digital Output/Input connection on GV50LTA. It  is of open drain type and  the  maximum  drain  current  is  150mA.  The  OUT1/IN1  (PIN5)  can  be  used  as  a  digital Output and a (negative trigger) digital Input.  2.6. Digital Output/ Input Connection Queclink
GV50LTA Manage Tool User Guide      - 10 -   Figure 5: As Digital Output Internal Drive Circuit Table 6: Electrical Characteristics of Digital Outputs Logical State Electrical Characteristics Enable <1.5V @150mA Disable Open drain      Figure 6: Typical Connection with Buzzer As Digital Output Table 7: Electrical Characteristics of Digital Inputs Logical State Electrical Characteristics Active 0V to 0.8V Inactive Open Queclink
GV50LTA Manage Tool User Guide      - 11 -   The following shows the recommended connection of a digital input.        Figure 7: Typical Digital Input Connection     There is a digital output (PIN6) on GV50LTA. It is of open drain type and the maximum drain current is 150mA.    Figure 8: Digital Output Internal Drive Circuit  2.7. Digital Output Queclink
GV50LTA Manage Tool User Guide      - 12 -  Table 8: Electrical Characteristics As Digital Outputs Logical State Electrical Characteristics Enable <1.5V @150mA Disable Open drain           Figure 9: Typical Connection with Relay Queclink
GV50LTA Manage Tool User Guide      - 13 -  3. Getting Started 3.1. Parts List Table 9: Parts List Name   Picture GV50LTA Locator           90mm*55mm*13mm         3.2. GV50LTA External Cable Interface Table 10: GV50LTA User Cable Colour Definition Definition Colour PIN No Cable RXD Orange 1   TXD Gray 2 VIN Red 3 IGN White 4 OUT1/IN1 Yellow 5 OUT2 Green 6 GND Black 7    Queclink
GV50LTA Manage Tool User Guide      - 14 -  3.3. Open the SIM Card cover  Figure 1. Open the SIM card cover  Follow the direction on the case and push to open the SIM card cover.  3.4. Clos the SIM Card cover   Figure 2. Close the SIM card cover Aligning and push to close the SIM card cover.  Queclink
GV50LTA Manage Tool User Guide      - 15 -  3.5. Install a SIM Card   Open  the  SIM  case  and  ensure  the  unit  is  not  powered  (unplug  the  7Pin  cable  to  the  OFF position). Slide the holder right to open the SIM card holder. Insert the SIM card into the holder as shown below with the orange colour. Take care to align the cut mark. Then close the case.  Figure 3. SIM Card Installation  3.6. Switch on the Backup Battery To use the GV50LTA backup battery, the switch must be in the ON position. The switch on the case and the ON/OFF position are shown below.    Figure 4. Switch and ON/OFF Position Note: 1. The switch must be in the “OFF” position when the GV50LTA is shipped on an aircraft. 2.  When the  switch is  in  the “OFF”  position, the battery cannot be  charged or  discharged and cannot be turned on.  ON OFF Queclink
GV50LTA Manage Tool User Guide      - 16 -  4. Troubleshooting and Safety Info 4.1. Troubleshooting 1 Trouble Possible reason Solution After GV50LTA is turned on, the CELL LED always flashes quickly. GV50LTA isn’t registered to the ISP. Please register the GV50LTA again and make sure the device gets the correct MDN. The signal is too weak; GV50LTA can’t be registered to the network. Please move GV50LTA into places with good LTE coverage. Messages can’t be reported to the backend server by LTE. The IP address or port of the backend server is wrong.   Make sure the IP address for the backend server is an identified address on the Internet. GV50LTA cannot power off no matter the device was in charge or not. Unable to power off GV50LTA if charger is connected. Disconnect charger, and try again. GV50LTA can’t get successful GPS fixing. The GPS signal is weak. Please move GV50LTA to a place with open sky. It is better to let the top surface face to sky. (The device has an LED indicator on the top surface.)   4.2. Safety Info  Please do not disassemble the device by yourself.    Please do not put the device in over heated too humid place, and avoid exposure to direct sunlight. Too high temperature will damage the device or even cause battery explosion.    Please do not use GV50LTA on the airplane or near medical equipment.