R H Peterson l VR-2 Remote Control Transmitter User Manual a2 170 pmd

R. H. Peterson Co.l Remote Control Transmitter a2 170 pmd

User Manual

Download: R H Peterson l VR-2 Remote Control Transmitter User Manual a2 170 pmd
Mirror Download [FCC.gov]R H Peterson l VR-2 Remote Control Transmitter User Manual a2 170 pmd
Document ID415005
Application IDR8xSHg4Z5rUiHFfDnBntXQ==
Document DescriptionUser Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize7.72kB (96539 bits)
Date Submitted2004-04-16 00:00:00
Date Available2004-04-15 00:00:00
Creation Date2004-03-29 08:09:13
Producing SoftwareAcrobat Distiller 5.0.5 (Windows)
Document Lastmod2004-03-29 08:09:13
Document Titlea2-170.pmd
Document CreatorPageMaker 7.0
Document Author: cpeace

ROBERT H. PETERSON CO.
MODEL# VR-2
DELUXE VARIABLE REMOTE SYSTEM
RECEIVER & TRANSMITTER KIT.
VR-2 SET
COMPRISES OF THE FOLLOWING PARTS:
Item No.
1.
2.
3.
4.
5.
6.
7.
Part No.
10281
10277
Description
Transmitter
Receiver
Valve Connection wiring
4x AA Batteries
Remote holder
Wall Switch
Mounting screws
INSTALLATION AND OPERATING INSTRUCTIONS
NOTICE TO INSTALLER:
Please leave these instructions with the consumer
NOTICE TO CONSUMER:
Please retain for future reference
RECEIVER INSTALLATION STEPS
ATTACH FEMALE
CONNECTORS
TO
CORRECT MALE
SPADES ON
VALVE
Step 1. Attach the supplied wires with female connectors to the proper
mating terminals on the valve (See Figure 1).
Step 2. Attach the open wire ends to terminal block marked "M"
on the receiver by connecting the marked wire to the
positive (+) terminal and the unmarked wire to the negative (-)
terminal. Tighten down the retaining screws (See Figure 2).
Step 3. To install batteries into the receiver, squeeze together the
tabs on the battery compartment and lift out (See Figure 3).
Insert the four (4) AA batteries (supplied with your kit) into the
compartment, ensuring they are correctly aligned by referring to the
markings in the compartment.Replace compartment.
NOTE: It is recommended that you replace the batteries annually
with fresh batteries. Always replace the four batteries at same time.
Figure 1
INSERT WIRING INTO RECEIVER &
TIGHTEN DOWN SCREWS AT BACK
Step 4. IMPORTANT: ACTIVATE YOUR RECEIVER BY PRESSING
THE RESET (LOCATED ABOVE THE SWITCH, SEE FIGURE 3)
WITH A FINE OBJECT SUCH AS A PAPERCLIP.
Place the receiver not closer than 18" to the log set.
An optional receiver cover (PCDC-1 or WCDC-1) is available from
your Peterson dealer.
Figure 2
OFF
PRESS
RESET
TO
ACTIVATE
RECEIVER
PRESS
TABS IN
TOWARDS
CENTER
& LIFT OUT
Figure 3
TO OPERATE REMOTE SEE PAGE 2
Rev 1 031004
REMOTE
To set up handset functions, follow instructions
on page 2, or the label on inside of handset cover.
Remote Functions available are:
Gas Log Set ON/OFF, Thermostatic control,
Timer control, Room Thermometer, Flame Height
control, and Sound control (when optional sound
device is connected)
An optional wall switch is supplied. See page 2
for installation instructions
OFF
Step 5. To activate the handset, open the battery
compartment at rear, and remove the white tag.
No. L-A2-17004
VR-2 TRANSMITTER/RECEIVER OPERATION
TIMER
Button
Data Change
Buttons
FLAME control
Button
SOUND button
MODE
CODE set button
(use paper clip)
OPTION
RESULT
PRESS ONCE
TURNS
HANDSET ON
TURNS LOG SET ON
PRESS
TWICE
TURNS ON
THERMOSTAT
CONTROL
TURNS LOG SET ON
IF ROOM TEMP IS LESS
THAN THERMOSTAT TEMP.
LOG SET TURNS OFF
IF ROOM TEMP IS
GREATER THAN
THERMOSTAT TEMP.
PRESS
ONCE (WHEN
"THERMO" ON)
TURNS
HANDSET OFF
USE UP & DOWN
BUTTONS TO SET
THERMOSTAT
TEMPERATURE
USE UP & DOWN
BUTTONS TO
INCREASES TIME
IN 15 MINUTE
INTERVALS UP TO
9 HOURS
PRESS
SOUND
PRESS
SWITCHES
OPTIONAL SOUND
ACCESSORY
ON/OFF
FLAME
PRESS
ALLOWS
CONTROL OF
FLAME HEIGHT
USE UP/DOWN TO
INCREASE OR
DECREASE
FLAME
PRESS
ONCE
ALLOWS CLOCK
(HOUR) TO BE
CHANGED
USE UP/DOWN TO
CHANGE SETTING
PRESS
TWICE
ALLOWS CLOCK
(MINUTES) TO BE
CHANGED
USE UP/DOWN TO
CHANGE SETTING
PRESS
KEEPS DATA
SETTING FOR
TIMER,
THERMOSTAT &
CLOCK
NOTE: For quick
ON/OFF and/or
15 minuteTIMER,
press the MODE
and/or TIMER
buttons on handset
outer cover.
GAS LOG SET ACTION
TURNS LOG SET OFF
TIMER
SET
WALL SWITCH MOUNT
ACTION
STARTS /STOPS
TIMER OPTION
TIME
To turn off the Remote option
and control the log set
manually, set the receiver
switch to "OFF"
( top or bottom position)
To set the switch for Remote
use, set the receiver switch to
"REMOTE"(center position)
TIME button
SET Data
Button
BUTTON
TOP
OFF
ON/OFF indicator
Thermostat
indicator
Thermostat set
temperature
Flame on/height
indicator
MODE button
USING THE RECEIVER TO
CONTROL LOG SET
REMOTE
Timer
indicator
Sound on
indicator
Room
temperature
Time
OFF
USING THE REMOTE TO CONTROL LOG SET
TURNS LOG SET OFF
WHEN TIMER FINISHES
NOTE: MANUALLY TURN
SOUND OFF WHEN
TURNING OFF LOG SET
IF TURNED ALL THE WAY
DOWN , WILL TURN
LOG SET OFF
1. Select a location for the Wall Switch near the
fireplace, up to 10 feet maximum from the
fireplace for the length of wiring supplied.
2. Cut out a clearance hole for direct wall or switch
box mounting. NOTE: Allow 3” deep (or greater)
space for the battery holder.
3. Tie 6" of chain (or a small weight) to a cord creating
a plumb line. Hang line from the location to the
top of wall baseboard. At this point (indicated by
the plumb line) drill a 1/2" to 3/4" hole.
4. Lower the line through the upper hole, within the
stud space, down to baseboard level. Pull weight
out of the lower hole using a stiff hooked wire (a
bent wire coat hanger works well) and remove
weight from the plumb line. Tie one end of the
Wire Cable to the plumb line and pull the line back
up through the Wall Switch location to expose
several inches of wire.
5. Connect the lower portion of wiring to the
connectors on the toggle switch on the valve, or
pine cone switch (see figure 1a and 1b).
6. Connect the other end of the wiring to receiver
terminals as shown in Figure 2. Insert 4 AA
batteries in the battery holder.
7. Attach the Wall Switch cover to the switch box
using the 1/4 inch machine screws supplied.
USING THE WALL SWITCH
To turn off remote option, set
wall switch to "OFF"
(top or bottom position)
To set for remote use, set wall
switch to "REMOTE"
(center position)
When operating remote, point
handset towards wall switch
Move switch to
desired setting:
top = REMOTE OFF
(for manual control
of log set)
center = REMOTE ON
(allows remote use)
bottom = REMOTE OFF
(for manual control
of log set)
FCC ID: RWPRR-2
This device complies with part 15 of the FCC rules. Operation of this device is subject to the following conditions:
(1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired operation.
Caution: Changes or modifications not expressly approved by the party responsible for compliance could void the users
authority to operate this equipment.
Robert H. Peterson Co. 14724 East Proctor Avenue, City of Industry, California 91746

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.3
Linearized                      : No
Create Date                     : 2004:03:29 08:09:13-08:00
Modify Date                     : 2004:03:29 08:09:13-08:00
Page Count                      : 2
Creation Date                   : 2004:03:29 16:09:13Z
Mod Date                        : 2004:03:29 16:09:13Z
Producer                        : Acrobat Distiller 5.0.5 (Windows)
Author                          : cpeace
Metadata Date                   : 2004:03:29 16:09:13Z
Creator                         : cpeace
Title                           : a2-170.pmd
EXIF Metadata provided by EXIF.tools
FCC ID Filing: RWPVR-2

Navigation menu