Download: Mirror Download [FCC.gov] Document ID 597790 Application ID XmGpbl7/UWk9QZiUlkzkVA== Document Description Users Manual Revision 2 Short Term Confidential No Permanent Confidential No Supercede No Document Type User Manual Display Format Adobe Acrobat PDF - pdf Filesize 33.83kB (422887 bits) Date Submitted 2005-11-01 00:00:00 Date Available 2005-12-16 00:00:00 Creation Date 2005-10-17 02:38:12 Producing Software Acrobat Distiller 5.0 (Windows) Document Lastmod 2005-10-31 22:13:23 Document Title Users Manual Revision 2
HB 1900
(Heartbeat 1900)
User’s Manual
R-TRON Proprietary & Confidential
Page 1
Copyright
Copyright of this manual belongs to R-tron America, Inc.
Reproduction, distribution or revision of part or all of contents in this manual in any form without
written permission of R-tron America, Inc. is not permitted
Registered Trademark
R-tron
is registered trademarks of R-tron America, Inc
Other products and company names mentioned herein this manual might be trade marks
or trade names of their respective owners.
HB 1900
The results of using information not mentioned in this manual or the risk of
misunderstanding this document remain with the user.
The information in this manual is subject to change due to function enhancement,
change of design, etc. If you want the modified manual or have any question on this
manual, please contact us at:
R-tron America, Inc Address : 10977 Granada Lane, Suite #225
Copyright © 2004Overland
R-TRON, Inc.
All KS
Rights
Reserved
Park,
66212
Tel : +1-913-593-5205
Copyright © 2005 R-tron America, Inc. All Rights Reserved
R-TRON Proprietary & Confidential
Page 2
Revision History
Version
Date of revision
Reason for revision
V1.0
Sep.21.2005
The First Edition
V1.1
Oct.05.2005
Second Edition
Revision Description
RF EXPOSURE INFORMATION
The antenna used for this transmitter must not exceed 2.5dBi and must be installed to
provide a minimum separation distance of 20cm from all persons.
R-TRON Proprietary & Confidential
Page 3
1. Overview
HB(Heart Beat)1900 is designed for the purpose of checking the repeater systems which were
installed in Sprint network.
Using CDMA 1x modem protocol, heartbeat is happened only when the repeater system
operates correctly. It traces the repeater status and give heartbeat signal periodically to WNMC
server through SNMP Trap.
2. HB 1900 Description
R-TRON Proprietary & Confidential
Page 4
2.1 HB 1900 Specification
2.1.1 Environmental conditions
Item
Standard
Power supply
85V~264V, 50/60Hz typ.
Operating temperature
Storage temperature
Humidity
Consumption power
- 20 ~ +50℃
- 30 ~ +60℃
95 %
15W
Remark
Table 1. Environmental Specification of HB 1900
2.1.2 System Specification
Item
Specifications
Frequency
Down Link
range
Up Link
Heartbeat interval
Interface Connector
VSWR
Atten Range
Atten Control Accuracy
Dimension(W*D*H)
Weight
1930 ~ 1990MHz
1850 ~ 1910 MHz
3~59 min
RS-232C
≤1.5
1~30dB
±1.5dB
170*300*74
2.4kg
Remark
1dB Step
Unit : mm
Table 2. features Specification of HB 1900
2.2 HB 1900 Block Diagram
R-TRON Proprietary & Confidential
Page 5
3. SUB Unit description & Specification
3.1 Attenuation Module
Attenuation Module function is sending signal to modem which is properly leveled and it sends
Signal to repeater wirelessly, controlling modem output level.
* Specification *
Item
Down Link
Up Link
Frequency
range
Specifications
1930~1990 MHz
1850~1910 MHz
Remark
Frequency range
Ant <-> In/Out
Insertion Loss
-15dB ± 1dB
(1850 MHz ~1990 MHz)
@ ATT 0dB
Max
Ant Port
-10dBm
Input Power
In/Out Port
20dBm(100mW)
ATT Range
VSWR - S11,S22
RF
Ant Port
30dB / 1dB Step
1 : 1.3 Min
SMA Female Type
Connector
In/Out Port
SMA Female Type
Interface Connector
Molex 5264-7p
Operating Temp.
-30℃ ~ +60℃
Operating Voltage
DC 5V ± 0.5V
Dimension(W*D*H)
60*90*30
Table 3. Specification of Atten Module
R-TRON Proprietary & Confidential
Active Low
Unit : mm
Page 6
3.2 Wireless Modem (Expedite C201)
Wireless Modem (Expedite C201) is designed for WNMC interconnection function
* Specification *
Item
Frequency
Down Link
range
Up Link
Storage Temperature
Operating Temperature
RF Channel Bandwidth
Frequency Accuracy
Operating Voltage
Maximum Output Power
Dinamic Range
Specifications
1930 ~ 1990MHz
1850 ~ 1910 MHz
-30℃ to + 85℃
-20℃ to +60℃
1.25MHz
±150Hz
3.45V to 4.20V
100mW (20.0dBm)
-104dBm ~ -64dBm
Remark
3.3 SNMP Board
R-TRON Proprietary & Confidential
Page 7
The SNMP Board located in the HB 1900 cabinet which is the essential of the HB 1900.
The SNMP board contains powerful microprocessors.
Operational parameters, such as Heartbeat interval, Modem Attenuation, SNMP version, Site ID,
etc. are set using a desktop or notebook and OMT, which communicate, locally via RS-232C
cable, with the RRMS. Remote operation is performed via CDMA net
* Connection *
Port
Connected to
J1
SNMP Board Vcc
J4
Debugging port
J5
ATTEN Module Vcc & Control
D-SUB 9PIN
Local OMT
* LED *
LED
TxD
Display communication status between Modem &SNMP Board
RxD
Display communication status between Modem &SNMP Board
OPR
Turn on a light in Heartbeat Range
RDY
Turn on a light when modem power is on
3.4 AC/DC Power Supply Unit
PSU receives and converts input power (AC 110V) into DC +5V.
R-TRON Proprietary & Confidential
Page 8
* Specification *
Item
Operating Temp
Storage Temp
Environmental
Humidity
Cooling method
Voltage
Current
Frequency
Leakage Current
Specifications
Remark
-10℃~60℃
-20℃~70℃
20%~90%RH
Natural air
AC85~264V
3A Max / 5Vdc
47~440Hz max(50~60Hz typ)
0.5mA max.@110V AC
* Specification *
Item
Operating Temp
Storage Temp
Environmental
Humidity
Cooling method
Voltage
Current
Frequency
Leakage Current
R-TRON Proprietary & Confidential
Specifications
Remark
-10℃~60℃
-20℃~75℃
20%~90%RH
Natural air
AC85~264V
3A Max / 5Vdc
47~440Hz
0.75mA max. 60Hz
Page 9
3.5 Antenna
* ELECTRICAL Specification *
Item
Frequency
Down Link
range
Up Link
Max input power
VSWR
Gain
Radiation pattern
Polarization
Antenna Type
Impedance
Specifications
1930 ~ 1990MHz
1850 ~ 1910 MHz
5W
Less than 1.5:1
2.0dBi±0.5
Omni-directional
Remark
VERTICAL
Sleeve dipole
50 Ω
* MECHANICAL SPECIFICATIONS *
Item
Overall Length of Ant
Weight
Temperature
Cover material
Connector Type
Specifications
166.5 ±2.0 mm
30 g
-30℃~+70℃
Remark
Urethane (HI 153-9082)
White COLOR
SMA-Male
4. Installation
4.1 How to install Program File
GUI program consists of one exe file. Therefore, you can copy one exe file to your PC and use it.
R-TRON Proprietary & Confidential
Page 10
4.2 Connect communication cable
Connect communication cable as followings,
4.3 Power on
After connecting the communication cable, you can supply AC power to the HB 1900. As you
can see the following picture, when you supply AC power to the HB 1900, the DC 5V LED light
up one time. After 3 or 4 seconds later, the modem power(3.3Voltage) LED light up two times.
Then 10 seconds later, the LED light three times. This signals that the heartbeat unit is ready for
communication. Finally, you can execute GUI program and get the heartbeat communication
started.
4.4 How to start GUI Program
Click HB 1900 v1_2.exe.
R-TRON Proprietary & Confidential
Page 11
When you click HB 1900 v1_2.exe, you will see the following pop-up window.
4.5 How to use and configure the Graphic User Interface (GUI)
4.5.1 Login / Logout
To proceed using the GUI Program, a user should log-in.
There are two kinds of users. One is the‘root’ and the other is the‘operator’. The ‘root’ user, the
can control all GUI buttons but the ‘operator’, can not use debugging pop-up window. Input
classified user IDs(‘root’ or ‘operator’) and assess password. After that,all default buttons will be
activated.
4.6 How to set up a communication port
After setting up the GUI Login, you should set up the communication port between the system
R-TRON Proprietary & Confidential
Page 12
and GUI. The Communication protocol is a RS-232C protocol between the SNMP board and the
PC serial port which is set up by the GUI. The Current RCU transmit speed is fixed at
11,5200bps. As you can see in the above picture, you can select the proper COM port and then
click the ‘START’ button. Now the RCU communication is started. If there is no problem with the
communication, the Rx LED will light up green with the Tx and Rx lighting up green, alternately.
4.7 Check setting figures
As shown in the above picture, you can check the Site ID(Cascade Code) , WNMC Phone
Number , WNMC IP Address , SNMP Version and Modem Phone Number. When you change
the current GUI settings, you can input the needed numbers in the white boxes and click toggle
switch to store the values.
4.7.1 How to set Parameter value
4.7.1.1 Cascade code Input
ex) Cascade Code which is given by a wireless operator : test01
Type Cascade code in white activated box.
R-TRON Proprietary & Confidential
Click “SiteID Set” button.
Page 13
4.7.1.2 Input WNMC Phone Number
Sprint WNMC Phone Number is #777 and procedures is as followings,
Type “#777” in white activated box
Click “Phone Number Set” button
4.7.1.3 WNMC IP Address입력
Sprint WNMC Server IP Address는 10.22.25.15 and procedures is as followings,
Type “10.22.25.15” in white activated box.
R-TRON Proprietary & Confidential
Click “IP Address Set” button.
Page 14
4.7.1.4 Input Modem Phone Number
Type modem phone number which you are going to put it into HB 1900.
Each modem phone number is different.
For example, when it comes to modem phone
Click “Modem NUM Set”
number is 5022759735, type this number
in white activated box.
2.4 How to check Modem
You can set the network connection status in ‘modem mode’ using the modem status pop-up
window and entering information in the ‘modem statistics’ pop-up window as followings,
R-TRON Proprietary & Confidential
Page 15
①
When the Modem is properly connected, you will see ‘READY’ im green, like in the
above picture[number 1].
②
Then you can click the NMST button [number 2] and test the AT Command. When
you see the ‘OK’ response, this means that the modem and SNMP board status is
Okay.
2.5 Check RSSI Value and Set Attenuation
2.5.1 Set Attenuation
After check the RSSI value which is displayed on the GUI, set the RSSI value as -70dBm, using
the modem attenuation. For example, when the GUI RSSI value is -67dBm, you can set it as 70dBm, using the modem attenuation 3dB. To set the attenuation, you can input the attenuation
value in white box and then click the ‘modem atten’ button which is located on the left side to
store it. (Ex-factory setting value of HB 1900 : user attenuation is 12dB , Heartbeat interval is
5 minutes.)
Ex) How to set User Attenuation
Antenna input Level
Fixed Loss
User Attenuation
Reference RSSI Value
-30dBm
-15dB
-25 dB
-70dBm
-40dBm
-15dB
-15 dB
-70dBm
-50dBm
-15dB
-5 dB
-70dBm
R-TRON Proprietary & Confidential
Page 16
2.5.2 Set Heartbeat Interval
Type heartbeat interval in white
Click “Heartbeat Interval” button.
activated box.
(Heartbeat Interval Range : 3 ~59 min)
2.6 How to check PPP connection and heartbeat
Set heartbeat interval as 20 minutes and then change network connection status to ‘PPP Mode’.
Heartbeat Transmit
Connected
Status Check
R-TRON Proprietary & Confidential
Page 17
Source Exif Data:
File Type : PDF
File Type Extension : pdf
MIME Type : application/pdf
PDF Version : 1.4
Linearized : No
Modify Date : 2005:10:31 22:13:23-05:00
Create Date : 2005:10:17 02:38:12Z
Page Count : 17
About : uuid:3a3aa7c8-f6ef-4614-8d05-46bc005007c5
Producer : Acrobat Distiller 5.0 (Windows)
Creation Date : 2005:10:17 02:38:12Z
Mod Date : 2005:10:31 22:13:23-05:00
Metadata Date : 2005:10:31 22:13:23-05:00
Document ID : uuid:ed2de178-40da-422e-b3e0-1ef9529e71c6
Format : application/pdf
EXIF Metadata provided by EXIF.tools