R tron RSP-DPP-1900 HB1900 User Manual Revision 2

R-tron Inc. HB1900 Users Manual Revision 2

Users Manual Revision 2

Download: R tron RSP-DPP-1900 HB1900 User Manual Revision 2
Mirror Download [FCC.gov]R tron RSP-DPP-1900 HB1900 User Manual Revision 2
Document ID597790
Application IDXmGpbl7/UWk9QZiUlkzkVA==
Document DescriptionUsers Manual Revision 2
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize33.83kB (422887 bits)
Date Submitted2005-11-01 00:00:00
Date Available2005-12-16 00:00:00
Creation Date2005-10-17 02:38:12
Producing SoftwareAcrobat Distiller 5.0 (Windows)
Document Lastmod2005-10-31 22:13:23
Document TitleUsers Manual Revision 2

HB 1900
(Heartbeat 1900)
User’s Manual
R-TRON Proprietary & Confidential
Page 1
Copyright
Copyright of this manual belongs to R-tron America, Inc.
Reproduction, distribution or revision of part or all of contents in this manual in any form without
written permission of R-tron America, Inc. is not permitted
Registered Trademark
R-tron
is registered trademarks of R-tron America, Inc
Other products and company names mentioned herein this manual might be trade marks
or trade names of their respective owners.
HB 1900
The results of using information not mentioned in this manual or the risk of
misunderstanding this document remain with the user.
The information in this manual is subject to change due to function enhancement,
change of design, etc. If you want the modified manual or have any question on this
manual, please contact us at:
R-tron America, Inc Address : 10977 Granada Lane, Suite #225
Copyright © 2004Overland
R-TRON, Inc.
All KS
Rights
Reserved
Park,
66212
Tel : +1-913-593-5205
Copyright © 2005 R-tron America, Inc. All Rights Reserved
R-TRON Proprietary & Confidential
Page 2
Revision History
Version
Date of revision
Reason for revision
V1.0
Sep.21.2005
The First Edition
V1.1
Oct.05.2005
Second Edition
Revision Description
RF EXPOSURE INFORMATION
The antenna used for this transmitter must not exceed 2.5dBi and must be installed to
provide a minimum separation distance of 20cm from all persons.
R-TRON Proprietary & Confidential
Page 3
1. Overview
HB(Heart Beat)1900 is designed for the purpose of checking the repeater systems which were
installed in Sprint network.
Using CDMA 1x modem protocol, heartbeat is happened only when the repeater system
operates correctly. It traces the repeater status and give heartbeat signal periodically to WNMC
server through SNMP Trap.

2. HB 1900 Description
R-TRON Proprietary & Confidential
Page 4
2.1 HB 1900 Specification
2.1.1 Environmental conditions
Item
Standard
Power supply
85V~264V, 50/60Hz typ.
Operating temperature
Storage temperature
Humidity
Consumption power
- 20 ~ +50℃
- 30 ~ +60℃
95 %
15W
Remark
Table 1. Environmental Specification of HB 1900
2.1.2 System Specification
Item
Specifications
Frequency
Down Link
range
Up Link
Heartbeat interval
Interface Connector
VSWR
Atten Range
Atten Control Accuracy
Dimension(W*D*H)
Weight
1930 ~ 1990MHz
1850 ~ 1910 MHz
3~59 min
RS-232C
≤1.5
1~30dB
±1.5dB
170*300*74
2.4kg
Remark
1dB Step
Unit : mm
Table 2. features Specification of HB 1900
2.2 HB 1900 Block Diagram
R-TRON Proprietary & Confidential
Page 5
3. SUB Unit description & Specification
3.1 Attenuation Module
Attenuation Module function is sending signal to modem which is properly leveled and it sends Signal to repeater wirelessly, controlling modem output level. * Specification * Item Down Link Up Link Frequency range Specifications 1930~1990 MHz 1850~1910 MHz Remark Frequency range Ant <-> In/Out Insertion Loss -15dB ± 1dB (1850 MHz ~1990 MHz) @ ATT 0dB Max Ant Port -10dBm Input Power In/Out Port 20dBm(100mW) ATT Range VSWR - S11,S22 RF Ant Port 30dB / 1dB Step 1 : 1.3 Min SMA Female Type Connector In/Out Port SMA Female Type Interface Connector Molex 5264-7p Operating Temp. -30℃ ~ +60℃ Operating Voltage DC 5V ± 0.5V Dimension(W*D*H) 60*90*30 Table 3. Specification of Atten Module R-TRON Proprietary & Confidential Active Low Unit : mm Page 6 3.2 Wireless Modem (Expedite C201)
Wireless Modem (Expedite C201) is designed for WNMC interconnection function * Specification * Item Frequency Down Link range Up Link Storage Temperature Operating Temperature RF Channel Bandwidth Frequency Accuracy Operating Voltage Maximum Output Power Dinamic Range Specifications 1930 ~ 1990MHz 1850 ~ 1910 MHz -30℃ to + 85℃ -20℃ to +60℃ 1.25MHz ±150Hz 3.45V to 4.20V 100mW (20.0dBm) -104dBm ~ -64dBm Remark 3.3 SNMP Board
R-TRON Proprietary & Confidential Page 7 The SNMP Board located in the HB 1900 cabinet which is the essential of the HB 1900. The SNMP board contains powerful microprocessors. Operational parameters, such as Heartbeat interval, Modem Attenuation, SNMP version, Site ID, etc. are set using a desktop or notebook and OMT, which communicate, locally via RS-232C cable, with the RRMS. Remote operation is performed via CDMA net * Connection * Port Connected to J1 SNMP Board Vcc J4 Debugging port J5 ATTEN Module Vcc & Control D-SUB 9PIN Local OMT * LED * LED TxD Display communication status between Modem &SNMP Board RxD Display communication status between Modem &SNMP Board OPR Turn on a light in Heartbeat Range RDY Turn on a light when modem power is on 3.4 AC/DC Power Supply Unit
PSU receives and converts input power (AC 110V) into DC +5V. R-TRON Proprietary & Confidential Page 8 * Specification * Item Operating Temp Storage Temp Environmental Humidity Cooling method Voltage Current Frequency Leakage Current Specifications Remark -10℃~60℃ -20℃~70℃ 20%~90%RH Natural air AC85~264V 3A Max / 5Vdc 47~440Hz max(50~60Hz typ) 0.5mA max.@110V AC * Specification * Item Operating Temp Storage Temp Environmental Humidity Cooling method Voltage Current Frequency Leakage Current R-TRON Proprietary & Confidential Specifications Remark -10℃~60℃ -20℃~75℃ 20%~90%RH Natural air AC85~264V 3A Max / 5Vdc 47~440Hz 0.75mA max. 60Hz Page 9 3.5 Antenna
* ELECTRICAL Specification * Item Frequency Down Link range Up Link Max input power VSWR Gain Radiation pattern Polarization Antenna Type Impedance Specifications 1930 ~ 1990MHz 1850 ~ 1910 MHz 5W Less than 1.5:1 2.0dBi±0.5 Omni-directional Remark VERTICAL Sleeve dipole 50 Ω * MECHANICAL SPECIFICATIONS * Item Overall Length of Ant Weight Temperature Cover material Connector Type Specifications 166.5 ±2.0 mm 30 g -30℃~+70℃ Remark Urethane (HI 153-9082) White COLOR SMA-Male 4. Installation 4.1 How to install Program File GUI program consists of one exe file. Therefore, you can copy one exe file to your PC and use it. R-TRON Proprietary & Confidential Page 10 4.2 Connect communication cable Connect communication cable as followings, 4.3 Power on After connecting the communication cable, you can supply AC power to the HB 1900. As you can see the following picture, when you supply AC power to the HB 1900, the DC 5V LED light up one time. After 3 or 4 seconds later, the modem power(3.3Voltage) LED light up two times. Then 10 seconds later, the LED light three times. This signals that the heartbeat unit is ready for communication. Finally, you can execute GUI program and get the heartbeat communication started. 4.4 How to start GUI Program Click HB 1900 v1_2.exe. R-TRON Proprietary & Confidential Page 11 When you click HB 1900 v1_2.exe, you will see the following pop-up window. 4.5 How to use and configure the Graphic User Interface (GUI) 4.5.1 Login / Logout To proceed using the GUI Program, a user should log-in. There are two kinds of users. One is the‘root’ and the other is the‘operator’. The ‘root’ user, the can control all GUI buttons but the ‘operator’, can not use debugging pop-up window. Input classified user IDs(‘root’ or ‘operator’) and assess password. After that,all default buttons will be activated. 4.6 How to set up a communication port After setting up the GUI Login, you should set up the communication port between the system R-TRON Proprietary & Confidential Page 12 and GUI. The Communication protocol is a RS-232C protocol between the SNMP board and the PC serial port which is set up by the GUI. The Current RCU transmit speed is fixed at 11,5200bps. As you can see in the above picture, you can select the proper COM port and then click the ‘START’ button. Now the RCU communication is started. If there is no problem with the communication, the Rx LED will light up green with the Tx and Rx lighting up green, alternately. 4.7 Check setting figures As shown in the above picture, you can check the Site ID(Cascade Code) , WNMC Phone Number , WNMC IP Address , SNMP Version and Modem Phone Number. When you change the current GUI settings, you can input the needed numbers in the white boxes and click toggle switch to store the values. 4.7.1 How to set Parameter value 4.7.1.1 Cascade code Input ex) Cascade Code which is given by a wireless operator : test01 Type Cascade code in white activated box. R-TRON Proprietary & Confidential Click “SiteID Set” button. Page 13 4.7.1.2 Input WNMC Phone Number Sprint WNMC Phone Number is #777 and procedures is as followings, Type “#777” in white activated box Click “Phone Number Set” button 4.7.1.3 WNMC IP Address입력 Sprint WNMC Server IP Address는 10.22.25.15 and procedures is as followings, Type “10.22.25.15” in white activated box. R-TRON Proprietary & Confidential Click “IP Address Set” button. Page 14 4.7.1.4 Input Modem Phone Number Type modem phone number which you are going to put it into HB 1900. Each modem phone number is different. For example, when it comes to modem phone Click “Modem NUM Set” number is 5022759735, type this number in white activated box. 2.4 How to check Modem You can set the network connection status in ‘modem mode’ using the modem status pop-up window and entering information in the ‘modem statistics’ pop-up window as followings, R-TRON Proprietary & Confidential Page 15 ① When the Modem is properly connected, you will see ‘READY’ im green, like in the above picture[number 1]. ② Then you can click the NMST button [number 2] and test the AT Command. When you see the ‘OK’ response, this means that the modem and SNMP board status is Okay. 2.5 Check RSSI Value and Set Attenuation 2.5.1 Set Attenuation After check the RSSI value which is displayed on the GUI, set the RSSI value as -70dBm, using the modem attenuation. For example, when the GUI RSSI value is -67dBm, you can set it as 70dBm, using the modem attenuation 3dB. To set the attenuation, you can input the attenuation value in white box and then click the ‘modem atten’ button which is located on the left side to store it. (Ex-factory setting value of HB 1900 : user attenuation is 12dB , Heartbeat interval is 5 minutes.) Ex) How to set User Attenuation Antenna input Level Fixed Loss User Attenuation Reference RSSI Value -30dBm -15dB -25 dB -70dBm -40dBm -15dB -15 dB -70dBm -50dBm -15dB -5 dB -70dBm R-TRON Proprietary & Confidential Page 16 2.5.2 Set Heartbeat Interval Type heartbeat interval in white Click “Heartbeat Interval” button. activated box. (Heartbeat Interval Range : 3 ~59 min) 2.6 How to check PPP connection and heartbeat Set heartbeat interval as 20 minutes and then change network connection status to ‘PPP Mode’. Heartbeat Transmit Connected Status Check R-TRON Proprietary & Confidential Page 17

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
Modify Date                     : 2005:10:31 22:13:23-05:00
Create Date                     : 2005:10:17 02:38:12Z
Page Count                      : 17
About                           : uuid:3a3aa7c8-f6ef-4614-8d05-46bc005007c5
Producer                        : Acrobat Distiller 5.0 (Windows)
Creation Date                   : 2005:10:17 02:38:12Z
Mod Date                        : 2005:10:31 22:13:23-05:00
Metadata Date                   : 2005:10:31 22:13:23-05:00
Document ID                     : uuid:ed2de178-40da-422e-b3e0-1ef9529e71c6
Format                          : application/pdf
EXIF Metadata provided by EXIF.tools
FCC ID Filing: STERSP-DPP-1900

Navigation menu