R tron SN-WIMAX-24C WiMAX In-door Repeater User Manual Manaul RSN WiMAX 24C 090907

R-tron Inc. WiMAX In-door Repeater Manaul RSN WiMAX 24C 090907

User Manual

  User’s Manual                                                RSN-WiMAX-24C   Proprietary & Confidential                                                     Page 1                                                                               Issue: 1.0     RSN-WiMAX-24C User’s Manual    R-tron Inc.
  User’s Manual                                                RSN-WiMAX-24C   Proprietary & Confidential                                                     Page 2                                                                               Issue: 1.0         Warning ! Any changes or modifications to the equipment not expressly approved by the party   responsible for compliance could void user’s authority to operate the equipment.   Note !This unit was tested with shielded cables on the peripheral devices.     Shielded cables must be used with the unit to insure compliance.     Important ! To comply with RF exposure requirement, the antenna must be installed to provide a   separation distance of at least 20 cm from all persons and must not be co-located or   operating in conjunction with any other antenna or transmitter.   CAUTION This equipment is indoor use and all the communication
  User’s Manual                                                RSN-WiMAX-24C   Proprietary & Confidential                                                     Page 3                                                                               Issue: 1.0     Abbreviations Abbreviations used in this manual, in RSN-WiMAX-24C.  AC           Alternating Current ANT          Antenna WiMAX   Worldwide Interoperability for Microwave Access   SISO    Single Input Single Output DC           Direct Current  GND          Grounding GUI          Graphic User Interface LED          Light Emitting Diode PSU          Power Supply Unit MCU         Main Control Unit NCU    Network Control Unit UDC         Up Down Converter DFM    Digital Filter Module HPA   High Power Amplifier RF           Radio Frequency TEMP   Temperature VSWR    Voltage Standing Wave Ratio
  User’s Manual                                                RSN-WiMAX-24C   Proprietary & Confidential                                                     Page 4                                                                               Issue: 1.0     1. Introduction  RSN-WiMAX-24C repeater is used to fill out areas in Mobile WiMAX systems, such as base station fringe areas, business and industrial buildings, etc. RSN-WiMAX-24C receives signals from a base station, amplifies and retransmits the signals to mobile stations. Also it receives, amplifies and retransmits signals in the opposite direction. Both directions are served simultaneously with the following features:  188MHz bandwidth service   Band Selection (Continuous 30MHz) service  Roll Offs: 40 dBc at 1 MHz /80 dBc at 3.5 MHz outside pass-band  The RSN-WiMAX-24C Repeaters are controlled by powerful microprocessors. Operational status LEDs are visible on the front of the repeater.  The repeater works with convection cooling without fan because it has a radiator behind the body of RSN-WiMAX-24C. PSU BATTARY PORT AC IN. GUI DONORSERVERMODEM BOX POWERBRACKET LED SYNC OUT
  User’s Manual                                                RSN-WiMAX-24C   Proprietary & Confidential                                                     Page 5                                                                               Issue: 1.0    Operational parameters, such as gain, power levels, alarm condition, Automatic Gain Control condition, etc. are set using a desktop or notebook and the Local GUI or WEB GUI, which communicate, either locally or remotely via the UTP (Unshielded Twisted Pair Wire) cable, with the repeater.
  User’s Manual                                                RSN-WiMAX-24C   Proprietary & Confidential                                                     Page 6                                                                               Issue: 1.0     2. Description 2.1 System Specifications 2.1.1 Electrical Specifications Parameter  Down Link  Up Link Operating Frequency  2502MHz~2690MHz 2502MHz~2690MHz Freq. plan  AB/BC/CD/EF/FH/HG (*Gloss) Gain  50dB to 90dB Max output power  24dBm Roll off ≤40dBc @Fedge+/-1MHz ≤80dBc @Fedge+/-3.5MHz Gain ripple  ±1.5dB   Delay 5.0uS Max VSWR 1.5Max Input Range  -26dBm ~ -66dBm Power supply  110V~240V           , 50/60Hz typ. Operating temperature  -10℃~-50℃ Consumption power  ≤130W   Band Selection  Continuous 33MHz ACP -13dBm @ ± 16.5MHz from 3FA Center -13dBm @ ± 18.5MHz from 3FA Center -37dBm @ ± 20MHz from 3FA Center -37dBm @ ± 23MHz from 3FA Center *Gloss : Freq. Plan     AB : 2502~2535MHz     BC : 2518.5~2551.5MHz     CD : 2535~2568MHz     EF : 2624~2657MHz     FH : 2640.5~2673.5MHz       HG : 2673.5~2690MHz
  User’s Manual                                                RSN-WiMAX-24C   Proprietary & Confidential                                                     Page 7                                                                               Issue: 1.0     2.1.2 Mechanical Specifications Parameter  Specification RF connectors  N-female x 2, SMA-female x 3 Size  14 X15.55 X 7.87(Inch),   355 X 395 X 200(mm) Weight -
  User’s Manual                                                RSN-WiMAX-24C   Proprietary & Confidential                                                     Page 8                                                                               Issue: 1.0     2.2 Sub Unit Overview RSN-WiMAX-24C is composed of the following sub units:  UDC(Up Down Converter)  HPA(High Power Amplifier)   BPF(Band Pass Filter)   MCU (Main Control Unit)   NCU (Network Control Unit)   PSU (Power Supply Unit)   DFM (Digital Filter Module)   SWU (Switch Unit)  EMI Filter PSU NCU MCU DFM UDC SWU HPA BPF
  User’s Manual                                                RSN-WiMAX-24C   Proprietary & Confidential                                                     Page 9                                                                               Issue: 1.0     2.2.1 Block diagram The following, Figure explains how the RSN-WiMAX-24C serves signals.
  User’s Manual                                                RSN-WiMAX-24C   Proprietary & Confidential                                                     Page 10                                                                               Issue: 1.0     2.2.2 UDC Module The UDC Module is basically a bi-directional amplifier that sharply filters out   unwanted noise.  <UDC Module>  2.2.3 BPF BPF is the module which passes the frequency in BRS BAND. One BPF performs simultaneously DL INPUT, UP OUPUT functions.     2.2.4 Main Control Unit (MCU) MCU is the control unit of RSN-WiMAX-24C. It controls and monitors operational
  User’s Manual                                                RSN-WiMAX-24C   Proprietary & Confidential                                                     Page 11                                                                               Issue: 1.0    parameters.  It also generates alarms, an event log and many other functions of the RSN-WiMAX-24C.  *Pin Map* Port   Connected to   J3  RFU1 Control pin 1 J4  RFU1 Control pin 2 J5  HPA Control pin J6  PSU Control pin J7  Sync Unit Control pin J8 Local GUI J9 LED J11 NCU J12 SWU J13 Main Power(5.5V)     2.2.5 Network Control Unit (NCU) NCU is the unit that controls the device using Ethernet based WEB GUI Connection
  User’s Manual                                                RSN-WiMAX-24C   Proprietary & Confidential                                                     Page 12                                                                               Issue: 1.0      2.2.6 Power Supply The Power Supply Unit (PSU) supplies a steady DC power to RSN-WiMAX-24C by drawing power from the general in-wall AC outlets
  User’s Manual                                                RSN-WiMAX-24C   Proprietary & Confidential                                                     Page 13                                                                               Issue: 1.0    *Specification* Item   Specifications   Operating Temp  -10℃~50℃  Humidity   20%~90%RH  Environmental  Cooling method  Natural air   Voltage   AC110~240V  Current   3A Max / 7V, 5.5,-28V,12V, -12V , 28VDC  Frequency    50~60Hz typ  Leakage Current    0.5mA max.@110V AC    2.2.7 High Power Amplifier (HPA) The High Power Amplifiers the transmitted signal from a base station at the final   stage of the repeater and vice versa.  <HPA>
  User’s Manual                                                RSN-WiMAX-24C   Proprietary & Confidential                                                     Page 14                                                                               Issue: 1.0    2.2.8 Digital Filter Module (DFM)               <DFM>
  User’s Manual                                                RSN-WiMAX-24C   Proprietary & Confidential                                                     Page 15                                                                               Issue: 1.0     2.2.9 Switch Unit

Navigation menu