R tron SN-WIMAX-24C WiMAX In-door Repeater User Manual Manaul RSN WiMAX 24C 090907

R-tron Inc. WiMAX In-door Repeater Manaul RSN WiMAX 24C 090907

User Manual

Download: R tron SN-WIMAX-24C WiMAX In-door Repeater User Manual Manaul RSN WiMAX 24C 090907
Mirror Download [FCC.gov]R tron SN-WIMAX-24C WiMAX In-door Repeater User Manual Manaul RSN WiMAX 24C 090907
Document ID1184343
Application IDhVSHaa0pAqDO71qxBMXneA==
Document DescriptionUser Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize68.14kB (851797 bits)
Date Submitted2009-10-16 00:00:00
Date Available2009-10-16 00:00:00
Creation Date2009-10-16 13:55:08
Producing SoftwareAcrobat Distiller 7.0.5 (Windows)
Document Lastmod2009-10-16 13:56:14
Document TitleMicrosoft Word - Manaul_RSN-WiMAX-24C-090907.doc
Document CreatorPScript5.dll Version 5.2.2
Document Author: james_kwon

User’s Manual
RSN-WiMAX-24C
RSN-WiMAX-24C
User’s Manual
R-tron Inc.
Proprietary & Confidential
Page 1
Issue: 1.0
User’s Manual
RSN-WiMAX-24C
Warning !
Any changes or modifications to the equipment not expressly approved by the party
responsible for compliance could void user’s authority to operate the equipment.
Note !
This unit was tested with shielded cables on the peripheral devices.
Shielded cables must be used with the unit to insure compliance.
Important !
To comply with RF exposure requirement, the antenna must be installed to provide a
separation distance of at least 20 cm from all persons and must not be co-located or
operating in conjunction with any other antenna or transmitter.
CAUTION
This equipment is indoor use and all the communication
Proprietary & Confidential
Page 2
Issue: 1.0
User’s Manual
RSN-WiMAX-24C
Abbreviations
Abbreviations used in this manual, in RSN-WiMAX-24C.
AC
Alternating Current
ANT
Antenna
WiMAX
Worldwide Interoperability for Microwave Access
SISO
Single Input Single Output
DC
Direct Current
GND
Grounding
GUI
Graphic User Interface
LED
Light Emitting Diode
PSU
Power Supply Unit
MCU
Main Control Unit
NCU
Network Control Unit
UDC
Up Down Converter
DFM
Digital Filter Module
HPA
High Power Amplifier
RF
Radio Frequency
TEMP
Temperature
VSWR
Voltage Standing Wave Ratio
Proprietary & Confidential
Page 3
Issue: 1.0
User’s Manual
RSN-WiMAX-24C
1. Introduction
PSU
BRACKET
LED
AC IN.
DONOR
BATTARY
PORT
SERVER
GUI
MODEM
BOX
SYNC
POWER
OUT
RSN-WiMAX-24C repeater is used to fill out areas in Mobile WiMAX systems, such as base
station fringe areas, business and industrial buildings, etc.
RSN-WiMAX-24C receives signals from a base station, amplifies and retransmits the signals to
mobile stations. Also it receives, amplifies and retransmits signals in the opposite direction. Both
directions are served simultaneously with the following features:
„
188MHz bandwidth service
Band Selection (Continuous 30MHz) service
„
Roll Offs: 40 dBc at 1 MHz /80 dBc at 3.5 MHz outside pass-band
The RSN-WiMAX-24C Repeaters are controlled by powerful microprocessors. Operational
status LEDs are visible on the front of the repeater.
The repeater works with convection cooling without fan because it has a radiator behind the
body of RSN-WiMAX-24C.
Proprietary & Confidential
Page 4
Issue: 1.0
User’s Manual
RSN-WiMAX-24C
Operational parameters, such as gain, power levels, alarm condition, Automatic Gain Control
condition, etc. are set using a desktop or notebook and the Local GUI or WEB GUI, which
communicate, either locally or remotely via the UTP (Unshielded Twisted Pair Wire) cable, with
the repeater.
Proprietary & Confidential
Page 5
Issue: 1.0
User’s Manual
RSN-WiMAX-24C
2. Description
2.1 System Specifications
2.1.1 Electrical Specifications
Parameter
Down Link
Up Link
Operating Frequency
2502MHz~2690MHz
2502MHz~2690MHz
Freq. plan
AB/BC/CD/EF/FH/HG (*Gloss)
Gain
50dB to 90dB
Max output power
24dBm
Roll off
≤40dBc @Fedge+/-1MHz
≤80dBc @Fedge+/-3.5MHz
Gain ripple
±1.5dB
Delay
5.0uS Max
VSWR
1.5Max
Input Range
-26dBm ~ -66dBm
Power supply
110V~240V
, 50/60Hz typ.
Operating temperature
-10℃~-50℃
Consumption power
≤130W
Band Selection
Continuous 33MHz
-13dBm @ ± 16.5MHz from 3FA Center
ACP
-13dBm @ ± 18.5MHz from 3FA Center
-37dBm @ ± 20MHz from 3FA Center
-37dBm @ ± 23MHz from 3FA Center
*Gloss : Freq. Plan
AB : 2502~2535MHz
BC : 2518.5~2551.5MHz
CD : 2535~2568MHz
EF : 2624~2657MHz
FH : 2640.5~2673.5MHz
HG : 2673.5~2690MHz
Proprietary & Confidential
Page 6
Issue: 1.0
User’s Manual
RSN-WiMAX-24C
2.1.2 Mechanical Specifications
Parameter
Specification
RF connectors
N-female x 2, SMA-female x 3
Size
Weight
Proprietary & Confidential
14 X15.55 X 7.87(Inch),
355 X 395 X 200(mm)
Page 7
Issue: 1.0
User’s Manual
RSN-WiMAX-24C
2.2 Sub Unit Overview
RSN-WiMAX-24C is composed of the following sub units:
„
UDC(Up Down Converter)
„
HPA(High Power Amplifier)
„
BPF(Band Pass Filter)
„
MCU (Main Control Unit)
„
NCU (Network Control Unit)
„
PSU (Power Supply Unit)
„
DFM (Digital Filter Module)
„
SWU (Switch Unit)
„
EMI Filter
PSU
NCU
DFM
MCU
UDC
SWU
HPA
BPF
Proprietary & Confidential
Page 8
Issue: 1.0
User’s Manual
RSN-WiMAX-24C
2.2.1 Block diagram
The following, Figure explains how the RSN-WiMAX-24C serves signals.
Proprietary & Confidential
Page 9
Issue: 1.0
User’s Manual
RSN-WiMAX-24C
2.2.2 UDC Module
The UDC Module is basically a bi-directional amplifier that sharply filters out
unwanted noise.

2.2.3 BPF
BPF is the module which passes the frequency in BRS BAND. One BPF performs
simultaneously DL INPUT, UP OUPUT functions.
2.2.4 Main Control Unit (MCU)
MCU is the control unit of RSN-WiMAX-24C. It controls and monitors operational
Proprietary & Confidential
Page 10
Issue: 1.0
User’s Manual
RSN-WiMAX-24C
parameters. It also generates alarms, an event log and many other functions of the
RSN-WiMAX-24C.
*Pin Map*
Port
Connected to
J3
RFU1 Control pin 1
J4
RFU1 Control pin 2
J5
HPA Control pin
J6
PSU Control pin
J7
Sync Unit Control pin
J8
Local GUI
J9
LED
J11
NCU
J12
SWU
J13
Main Power(5.5V)
2.2.5 Network Control Unit (NCU)
NCU is the unit that controls the device using Ethernet based WEB GUI Connection
Proprietary & Confidential
Page 11
Issue: 1.0
User’s Manual
RSN-WiMAX-24C
2.2.6 Power Supply
The Power Supply Unit (PSU) supplies a steady DC power to RSN-WiMAX-24C by
drawing power from the general in-wall AC outlets
Proprietary & Confidential
Page 12
Issue: 1.0
User’s Manual
RSN-WiMAX-24C
*Specification*
Item
Specifications
Operating Temp
-10℃~50℃
Humidity
20%~90%RH
Cooling method
Natural air
Environmental
Voltage
Current
AC110~240V
3A Max / 7V, 5.5,-28V,12V, -12V ,
28VDC
Frequency
50~60Hz typ
Leakage Current
0.5mA max.@110V AC
2.2.7 High Power Amplifier (HPA)
The High Power Amplifiers the transmitted signal from a base station at the final
stage of the repeater and vice versa.

Proprietary & Confidential
Page 13
Issue: 1.0
User’s Manual
RSN-WiMAX-24C
2.2.8 Digital Filter Module (DFM)

Proprietary & Confidential
Page 14
Issue: 1.0
User’s Manual
RSN-WiMAX-24C
2.2.9 Switch Unit
Proprietary & Confidential
Page 15
Issue: 1.0

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
XMP Toolkit                     : 3.1-702
Producer                        : Acrobat Distiller 7.0.5 (Windows)
Creator Tool                    : PScript5.dll Version 5.2.2
Modify Date                     : 2009:10:16 13:56:14+09:00
Create Date                     : 2009:10:16 13:55:08+09:00
Metadata Date                   : 2009:10:16 13:56:14+09:00
Format                          : application/pdf
Title                           : Microsoft Word - Manaul_RSN-WiMAX-24C-090907.doc
Creator                         : james_kwon
Document ID                     : uuid:6d39cb00-80d7-48f1-a85d-eefcef4c3fee
Instance ID                     : uuid:5feb1778-d611-46c1-93a4-546f061d93ba
Page Count                      : 15
Author                          : james_kwon
EXIF Metadata provided by EXIF.tools
FCC ID Filing: STESN-WIMAX-24C

Navigation menu