R tron SNIDEN15DC Wireless Booster User Manual

R-tron Inc. Wireless Booster

DC Manual 2

System Manual                                                        RSN-iDEN-15-DC R-tron Proprietary & Confidential                                                  Page 12                                                                                  Issue: 1.0 2.2.6 High Power Amplifiers (HPAs) The High Power Amplifiers the transmitted signal from a base station at the final stage of the  Booster and vice versa.  <iDEN UL HPA>  <iDEN DL HPA>
System Manual                                                        RSN-iDEN-15-DC R-tron Proprietary & Confidential                                                  Page 13                                                                                  Issue: 1.0 2.2.6 EMI Noise Filter  2.2.7 Communication & LED Board
System Manual                                                        RSN-iDEN-15-DC R-tron Proprietary & Confidential                                                  Page 14                                                                                  Issue: 1.0  * Hardware Installation  1. Setting for Command and Control   *  iDEN MINI operates on a customer provided PC based platform with the following system requirements. Windows® XP  Strong recommended 128 MB RAM or more   Pentium Ⅲ processor or more  keyboard RJ-45 jack    Step 1 Open My Network Places.  Step 2 Click the “View network connections”.
System Manual                                                        RSN-iDEN-15-DC R-tron Proprietary & Confidential                                                  Page 15                                                                                  Issue: 1.0 Step 3 Push the right button of mouse and select the properties.   Step 4 Click the properties of TCP/IP.
System Manual                                                        RSN-iDEN-15-DC R-tron Proprietary & Confidential                                                  Page 16                                                                                  Issue: 1.0 Step 5 Set the values and OK as the following. Close all windows.   Step 6 Open a new explorer window.
System Manual                                                        RSN-iDEN-15-DC R-tron Proprietary & Confidential                                                  Page 17                                                                                  Issue: 1.0 Step 7 Type http://192.168.0.1:83 in the address box and press “Enter” key.   Step 8 Login with “administrator” of ID and “1234” of password and “OK”.
System Manual                                                        RSN-iDEN-15-DC R-tron Proprietary & Confidential                                                  Page 18                                                                                  Issue: 1.0 2. Command and Control on the Web GUI.   A. iDEN 800. a. To control the iDEN 800, check the box of iDEN 800.  b. The operating bandwidth, 18MHz-bandwidth and 7MHz-bandwidth, is possibly selected.       Select the operating bandwidth and push the “APPLY” and check the bandwidth.
System Manual                                                        RSN-iDEN-15-DC R-tron Proprietary & Confidential                                                  Page 19                                                                                  Issue: 1.0 c. The operating frequency is able to be selected. Select the operating frequency and push the “APPLY” and check the bandwidth and frequency.
System Manual                                                        RSN-iDEN-15-DC R-tron Proprietary & Confidential                                                  Page 20                                                                                  Issue: 1.0 B. iDEN 900. a. To control the iDEN 900, check the box of iDEN 900.  b. On the iDEN 900, 5MHz-bandwith is only available.       Select the operating frequency and push the “APPLY” and check the bandwidth and frequency.
System Manual                                                        RSN-iDEN-15-DC R-tron Proprietary & Confidential                                                  Page 21                                                                                  Issue: 1.0 C. DL and UL gain setting. a. Set the DL gain and UL gain, 50dB to 80dB, and push the “APPLY” button.  * Set the gain of iDEN 900 as same as the iDEN 800 gain setting.
System Manual                                                        RSN-iDEN-15-DC R-tron Proprietary & Confidential                                                  Page 22                                                                                  Issue: 1.0 D. HPA on and off. a. Press the “ON” and “OFF” and check the status.  The maximum output power for operating is +25dBm on both DL and UL.
System Manual                                                        RSN-iDEN-15-DC R-tron Proprietary & Confidential                                                  Page 23                                                                                  Issue: 1.0 * Reference    The Operating Bandwidth & Frequencies   Bandwidth Operating Frequency iDEN 800 18MHz-bandwidth Downlink 851~869MHz 851~868.8MHz 851~868.6MHz Uplink 806~824MHz 806~823.8MHz 806~823.6MHz 7MHz-bandwidth Downlink 862~869MHz 862~868.8MHz 862~868.6MHz Uplink 817~824MHz 817~823.8MHz 817~823.6MHz iDEN 900 5MHz-bandwidth Downlink 935~940MHz 935~939.8MHz 935~939.6MHz Uplink 896~901MHz 896~900.8MHz 896~900.6MHz  Operating bandwidth and Frequencies of iDEN

Navigation menu