R tron SPAPE030M PCS Band In-Building CDMA Booster User Manual
R-tron Inc. PCS Band In-Building CDMA Booster
R tron >
Manual
User’s Manual of Advanced MINI 30 RSP-APE-030M User’s Manual Contents 1. Overview ------------------------------------------------------------------------ 3 2. Specifications ---------------------------------------------------------------- 4 2.1 System specifications ------------------------------------------------------- 4 2.2 Antenna specifications ------------------------------------------------------ 5 2.3 Donor Antenna Diagrams -------------------------------------------------- 6 2.4 Distributor Antenna Diagrams -------------------------------------------- 6 3. System Configuration ---------------------------------------------------- 7 3.1 Block Diagram -----------------------------------------------------------------7 4. Installation ----------------------------------------------------------------------8 4.1 Installation Overview --------------------------------------------------------8 4.2 Safety ------------------------------------------------------------------------8 4.3 Installation information-1 ---------------------------------------------------9 4.4 Installation information-2 ---------------------------------------------------9 5. Graphic User Interface (for maintenance) ------------------- 10 5.1 GUI Overview --------------------------------------------------------------- 10 5.2 Preliminary steps for GUI Execution & Maintenance ------------- 11 5.3 How to operate GUI & Functions -------------------------------------- 12 R-tron., Inc. 2/15 page RSP-APE-030M User’s Manual 1. Overview Figure 1.1 RSP-APE-030M Repeater R-tron RSP-APE-030M Repeater can be used in CDMA service hole spots like in-buildings, underground and tunnels to cover its service area. This repeater system designed for dual and simultaneous service, namely, it receives signals from the base station through donor antenna, amplifies the signals and re-transmits it to one or other mobile terminals. Also, it amplifies the signals which comes from mobile terminals through distributor antenna and re-amplifies it to base station. Using local OMT(Operation and Maintenance Terminal) which is connected between repeater control board and personal or laptop computer, it is possible to check or to control repeater status. R-tron., Inc. 3/15 page RSP-APE-030M User’s Manual 2. Specifications 2.1 System specifications Parameter Frequency Band Specifications Down Link 1930 ~ 1995 MHz Up Link 1850 ~ 1915 MHz Maximum Down Link Transmit Power Up Link 5 or 10 or 15 MHz Gain 70dB Gain Adjustment Range 30dB in steps of 1dB Emissions ±885 kHz < -45 dBc ±1.98 MHz < -50 dBc ± 2.25 MHz < -13 dBm Ripple Freq. Selectivity 65MHz Bandwidth +15 dBm Operating Bandwidth Spurious Remark Max. 7 channels 1 dB Step RBW = 30 kHz RBW = 1 MHz < 3.5dB -40dB ≤ 16.0MHz Delay <5㎲ VSWR ≤ 1.5 Waveform Quality Factor > 0.912 Noise Figure ≤ 5.0dB Within operating bandwidth Table 2.1 Repeater Specification Figure 2.1 A body of the RSP-APE-030M R-tron., Inc. 4/15 page RSP-APE-030M User’s Manual 2.3 Donor Antenna Diagrams Figure 2.2 Donor Antenna 2.4 Distributor Antenna Diagrams Figure 2.3 Patch Antenna Figure 2.4 Omni Antenna R-tron., Inc. 6/15 page RSP-APE-030M User’s Manual 3. System Configuration 3.1 Block Diagram Figure 3.1 shows the block diagram of a band Selective repeater. This diagram is applicable to repeaters for CDMA systems. 3.1.1 Downlink signal path DL signal path gives a wireless mobile terminal path after receiving signal from base station, amplifying and noise filtering. Please refer to the following picture 3.1, RSP-APE-030M repeater block diagram. 3.1.2 Uplink signal path UL signal path gives a path after receiving signal from mobile terminal, amplifying and noise filtering. Please refer to the following picture 3.1, RSP-APE-030M repeater block diagram. R-tron., Inc. 7/15 page RSP-APE-030M User’s Manual 4. Installation 4.1 Installation Overview The following gives you guide how you can install R-tron repeater properly, considering field situation and installation specific conditions. 4.2 Safety 4.2.1 Purpose The following information gives you how you can proceed your job correctly and eliminate dangerous condition. 4.2.2 Application Range Installation supervisor should check and do the proper thing to check preliminary dangerous condition. 4.3 Installation information-1 4.3.1 Right-of-way - The repeater shall be installed in the location owned or leased by the carrier. - If the repeater is installed in the building, an appropriate space for the installation must be considered. 4.3.2 Conditions for the Installation space Repeater should be installed as followings : In the building - Avoid certain part which is located something heavy or water tank on the roof, considering weight balance. - Select certain place which is good for air ventilation. - There will be enough space to check the repeater. R-tron., Inc. 8/15 page RSP-APE-030M User’s Manual 4.4 Installation Information-2 The installation of the repeater depends on the types of support, location, and the demand of the carrier. Figure 4.1 Antenna & Repeater Installation 4.4.1 General Condition - Check whether the repeater status is correctly horizontal angle. - Check whether there is enough space for maintenance and repair. 4.4.2 Installing Band set - Repeater main box should be installed 8.2 inches at least, above from the ground. - When you install the repeater main box, do not impact on its installation to other repeaters maintenance. - Safety plate should be installed 8.2 inches at least, above from the ground. 4.4.3 Precautions - Never mount the donor or coverage antenna near a window, where Signal can easily pass through the glass - Mount the donor antenna as high as physically possible to the exterior of the building, maximizing the vertical separation between antennas and pointing away from the building, toward the base station site. - Install the antennas taking advantage of any existing building structure Such as brick walls, metal roofs, or multiple wall structures to additionally attenuate the path between them. - When using directional antennas inside the building to cover Corridors and hallways, point the interior antenna away from The donor antenna location . - In extreme cases, the building configuration may not allow for Such separation and isolation. If additional isolation is required, Coaxial attenuation may be inserted between the donor antenna and the repeater , with the potential compromise to the coverage within the building R-tron., Inc. 9/15 page RSP-APE-030M User’s Manual 5. Graphic User Interface (for maintenance) 5.1. GUI Overview The following picture is RSP-APE-030M GUI Configuration. Figure 5.1 Main window When you first execute main window, you can see the above picture and it show you repeater status. R-tron., Inc. 10/15 page RSP-APE-030M User’s Manual 5.2 Preliminary Steps for GUI Execution & Maintenance 5.2.1 Preliminary Steps before using GUI a. Check all connection status during the installation. b. Set the baud rate which you are going to use. c. Connect the repeater main power cable. d. Connect RSP-APE-030M “LOCAL OMT” with PC, using RS232 cable. Figure 5.2 Connection RSP-APE-030M with PC 5.2.2 Executing USB Driver & GUI program a. Excuting “PreInstaller” and check the USB driver is normal and the port number. Figure 5.3 USB Driver files b. Excuting “MINI30_USPCS” Figure 5.4 GUI files 5.2.3 GUI Communication When the communication between Personal Computer and Repeater MCU board is OK, Tx/Rx yellow LED which is up-left corner in the GUI screen will be flashed. Figure 5.5 Communication Verification LED R-tron., Inc. 11/15 page RSP-APE-030M User’s Manual 5.3 How to operate GUI & Functions Repeater can be controlled in Set-up mode. In Set-up pop-up window, you can input the value and control DL/UL HPA, AGC, Shutdown and attenuation. When you are going to check repeater status, click “Synchronize” button which is in the bottom side in the screen. After setting output value, you can set AGC/ASD level value, using AGC/ASD button. Figure 5.6 Setup mode R-tron., Inc. 12/15 page RSP-APE-030M User’s Manual 5.3.1 Description for icon indication Figure 5.7 Main icons ▶ Polling : Communication possible ▶ Stop : Stop Communication ▶ File : Load the file of downloading ▶ Exit : Exit 5.3.2 How to set repeater gain System gain value can be changed using Down/Up link attenuation value control which is in “ATTN” pop-up window. Available set attenuation value is from 0 to 30 dB, Down/Up Link both. You can check current system gain in status mode. Figure 5.8 Gain Setting R-tron., Inc. 13/15 page RSP-APE-030M User’s Manual 5.3.3 Circumstance Condition Control This function enables you to set the internal temperature of the system and the upper values of the input/output level. To change the values, you can enter the desired settings and click the “APPLY” button at the upper part of the control window. In the left side, you can see current settings for the internal temperature of the system. Figure 5.9 Control Window of Environmental Conditions 5.3.4 Controlling power amplifier On the “ON/OFF” window, you can control power amplifiers for each path. In the left side window, you can see the current path status (ON/OFF) of the system. Figure 5.10 Control Window of Power Amplifier and Battery 5.3.5 Controlling input/output You can set the upper/lower values of the current input/output RF power of the up-/down-links. To change the values, you can enter the desired settings and click the “SET” button at the upper part of the control window. In the status mode, you can see the current input/output settings of the up-/down-links. Figure 5.11 Controlling Input/output 5.3.6 AGC(Auto Gain Control) & ASD(Auto Shutdown) Setting This function lets you control AGC settings and the ON/OFF status. To change a setting, you need to enter a value and click the SET button at the lower part of the Control Window. R-tron., Inc. 14/15 page RSP-APE-030M User’s Manual Figure 5.12 AGC/ASD Setting window R-tron., Inc. 15/15 page
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : No Page Count : 15 XMP Toolkit : XMP toolkit 2.9.1-13, framework 1.6 About : uuid:a06d180a-cb05-4829-bca9-3b112674147b Producer : Acrobat Distiller 6.0 (Windows) Modify Date : 2006:05:23 20:26:18+09:00 Create Date : 2006:05:11 15:17:08+09:00 Metadata Date : 2006:05:23 20:26:18+09:00 Document ID : uuid:c4e70b70-b6fb-4a9d-9334-2cd3a93df975 Format : application/pdf Title : untitledEXIF Metadata provided by EXIF.tools