R tron SPAPP030M PCS Repeater User Manual

R-tron Inc. PCS Repeater Users Manual

Users Manual

       Mini 30mW User’s Manual
Mini 30mW   User’s Manual  R-Tron., Inc.                                                          2/15 page  Copyright Copyright of this manual belongs to R-TRON, Inc. Reproduction, distribution or revision of part or all of contents in this manual in any form without written permission of R-TRON, Inc. is prohibited.  Registered Trademark R-TRON     are registered trademarks of R-TRON, Inc. Other products and company names mentioned herein this manual might be trade marks or trade names of their respective owners.   RF Repeater Band Selective Type Sprint PCS             Copyright © 2005 R-TRON, Inc. All Rights Reserved The results of using the information not mentioned in this manual or the risk of misunderstanding this document remain with the user. The information in this manual is subject to change due to function enhancement, change of design, etc. If you want the modified manual or have any question on this manual, please contact us with information below:  Address :  Customer Support Center, Jisan IT Venture Bldg., 2/3F, 1004-9/10, Doksan-Dong, Gumcheon-Gu, Seoul 153-829 , South Korea Tel :  +82-2-896-4101
Mini 30mW   User’s Manual  R-Tron., Inc.                                                          3/15 page Revision History Version  Date of revision  Reason for revision   Revision Description V0.1 Agust.11, 2005             RF EXPOSURE INFORMATION  The antenna used for this transmitter must not exceed 12dBi and must be installed to provide a minimum separation distance of 20cm from all persons.
Mini 30mW   User’s Manual  R-Tron., Inc.                                                          4/15 page Contents 1. Overview -----------------------------------------------------------------------6 2. Repeater Design ----------------------------------------------------------7    2.1 System specifications --------------------------------------------------7 1. Mechanical and Environmental conditions --------------------------7 2. System Electrical Specifications ---------------------------------------7         A. Mini 30 (30mW) Repeater ------------------------------------------------7 B. Mini 30 (30mW) Antenna -------------------------------------------------9 3. Repeater Configurations -----------------------------------------10  3.1 Body -------------------------------------------------------------------------10   3.2 Antenna Unit -------------------------------------------------------------11  1. Donor Antenna (Yagi Antenna) -----------------------------------11   2. Distribution Antenna -------------------------------------------------11     A. Internal Patch Antenna ------------------------------------------------11       B. External Omni Antenna (Optional) -----------------------------------12   3.3 AC to DC SMPS Adapter -------------------------------------------12 4. Block Diagram -----------------------------------------------------------13   4.1 Downlink signal path ------------------------------------------------13 4.2 Uplink signal path -----------------------------------------------------13
Mini 30mW   User’s Manual  R-Tron., Inc.                                                          5/15 page 1. Overview  Mini 30 will bring in those weak cellular phone signals reducing dropped calls and allowing you to use cell phones ...even deep inside a building.  At the heart of all of our systems is a Mini 30 designed to improve coverage for wireless products within a facility. Combined with interior ceiling mounted low profile antennas, and an exterior mounted Yagi or Patch Antenna, the Mini 30 boosts the signal level for distribution within the interior areas, reducing the problem of dropped calls and signal fades. The Mini 30 can also be used in mobile applications, improving voice quality and range in areas of poor coverage.     Figure 2.1 Fundamental configuration of Mini 30  All of our packages are engineered using only FCC approved amplified components. They are designed not to disrupt local wireless communication but to add service to areas that otherwise would not have the coverage that the customer requires. All of Mini 30 is easily installed.
Mini 30mW   User’s Manual  R-Tron., Inc.                                                          6/15 page 2 Repeater Design  The Mini 30 is housed in an aluminum chassis that is waterproof for indoor use. The chassis has a design suited for indoor use.   The Mini 30 has several RF amplifiers and components on a board with an aluminum body. Furthermore, the RF components are implemented within RF CMOS IC or MMIC technologies. A board that contains several RF amplifiers and components is shielded under a metal cover. This amplifier board is different types depending on the supported system. The followings are the Technical Specification of Mini 30.  2.1 System specification  2.1.1 Mechanical and Environmental conditions  Parameter  Specification Power supply  AC 100~240V ; 50/60Hz ±5% Operating temperature  0 ~ +50℃ Humidity  10% ~ 85% Consumption power  < 24W RF connector  N-female Size(W X L X H)  160 X 252 X 80(mm) / 6.29 X 9.92 X 3.15(Inch) Weight  3.7(kg) / 8.16 (lbs)  Table 2-1. Mechanical & Environmental Conditions
Mini 30mW   User’s Manual  R-Tron., Inc.                                                          7/15 page 2.1.2 Electrical Specifications  A. Mini 30 Repeater  Parameter  Specification  Remark Down Link  1930 – 1990 MHz  Total 60 MHz Frequency Band Up Link  1850 – 1910 MHz  Total 60 MHz Down Link Transmit  Maximum Power  Up Link  +14.8 dBm (30mW)  Total Power on CDMA Output Power on Coupled Service Port  MAX. 5 dBm  Total Power on CDMA Gain  70dB  ± 1 dB   Gain Range  60 ~ 70dB   Gain Step  10 dB (1 dB Step)   Noise Figure  < 5 dB   Bandwidth(Type 1)  5 MHz    BW(Max. 3FA)  Any 5MHz of Total 60MHz (A1,A2,A3,D,B1,B2,B3,E,F,C1,C2,C3)Bandwidth(Type 2)  10 MHz    BW(Max. 7FA) Any 10MHz of Total 60MHz (A1A2,A2A3,A3D,DB1,B1B2,B2B3,B3E,EF,FC1,C1C2,C2C3) Bandwidth(Type 3)  15 MHz    BW(Max. 7FA) Any 15MHz of Total 60MHz (A,A2A3D,A3DB1,DB1B2,B,B2B3E,B3EF,EFC1,FC1C2,C) Bandwidth(Type 4)  20 MHz    BW(Max. 7FA) Any 20MHz of Total 60MHz (AD,A2A3DB1,A3DB1B2,DB,BE,B2B3EF,B3EFC1,EFC1C2,FC1C2C3)Passband Ripple  < 2.5 dB P-P  Operating Bandwidth Delay  < 12 microseconds   VSWR  ≤1.5  Fc±885kHz ≥ -45 dBc  RBW = 30 kHz In-band Nosie  Fc±1.98MHz ≥ -50 dBc RBW = 30 kHz Spurious Emissions  < -13 dBm (Fc ± 2.25 MHz)  RBW = 1 MHz  Table 2-2. Repeater Features
Mini 30mW   User’s Manual  R-Tron., Inc.                                                          8/15 page B. Mini 30 (30mW) Antenna  Specification Donor  Internal Distribution External Distribution (Optional) Parameter Yagi  Patch  Patch  Omni Frequency range  1850 - 1990MHz Frequency bandwidth  140MHz Antenna gain  Min. 12dBi  2dBi  8dBi  2dBi  Horizontal Min. 28°  70°  70°  360°  Beam width Vertical Min. 28° 70° 70° 70°  Polarization Vertical  VSWR  Max. 1: 1.5  Max. 1 : 1.3  Max. 1 : 1.3  Max. 1 : 1.5 Power Capability  50Watts  10Watts 10Watts 10Watts  Antenna Connector Port Type  N-Female  -  N-Female (-10dB Coupling) N-Female (-10dB Coupling)670 / 1.48  670 / 1.48  50 / 0.11  225 / 0.5  270 / 0.6 Dimension (W x H x D)(inch)  19.7x4.21x3.23 4.25x3.34x0.35 5.04x4.06x1.54 Φ 4.49 x 1.85 Impedance  50Ω  Table 2-3 Antenna Features
Mini 30mW   User’s Manual  R-Tron., Inc.                                                          9/15 page 3. Repeater Configurations  The Mini 30 consists largely of a body and an AC to DC SMPS Adapter. The body of the Mini 30 has an RF unit, and a main control unit.    3.1 Body  The following is the picture of the body of Mini 30.    Figure 3.1 A body of the Mini 30
Mini 30mW   User’s Manual  R-Tron., Inc.                                                          10/15 page 3.2 Antenna Unit    The Mini 30 has two antennas, a donor antenna and a distribution antenna, to provide a good communication service.  3.2.1 Donor Antenna (Yagi Antenna)  A donor antenna is used for receiving the transmitted signal from a base station.    Figure 3.2 A Yagi antenna (Donor antenna)
Mini 30mW   User’s Manual  R-Tron., Inc.                                                          11/15 page 3.2.2 Distribution Antenna    A distribution antenna serves to transmit the amplified signal to individual mobile station in the shaded area.  A. Internal Patch Antenna  a. Rear view                          b. Front view Figure 3.3 Internal Patch Antenna  B. External Patch Antenna (Optional)   Figure 3.4 External Patch Antenna
Mini 30mW   User’s Manual  R-Tron., Inc.                                                          12/15 page C. External Omni Antenna (Optional)    Figure 3.5 External Omni Antenna
Mini 30mW   User’s Manual  R-Tron., Inc.                                                          13/15 page 3.3 AC to DC SMPS Adapter  A SMPS Adapter supply DC power to an Mini 30.   Figure 3.6 AC to DC SMPS Adapter  A. Specification overview  Item  Input  Output DC 12V Voltage  AC 90 to 264V   50/60Hz  ±5%  Output Voltage Variation Ratio: less than  ±5% AC to DC Current   3.0A Efficiency  75% Min. at full load Power   36Watts  Table 3.1 The specification of AC to DC SMPS Adapter
Mini 30mW   User’s Manual  R-Tron., Inc.                                                          14/15 page 4. Block Diagram  DuplexerPLL:VariableRF Input  RF Output15dBm/TotalDuplexerPLL:Variable-55dBm/TotalSAWAttenuatorSAW SAWPLL:VariablePLL:VariableSAWAttenuatorSAWSAW  Figure 4.1 Block Diagram of Band Selective Repeater  Figure 4.1 shows a block diagram of a band selective repeater. This diagram is applicable to repeaters for CDMA systems.  4.1 Downlink signal path  The downlink signal path, i.e. from the base station through the repeater to the mobile station, is described for Mini 30 in the above block diagrams.  4.2 Uplink signal path    The uplink signal path, i.e. from the mobile station through the repeater to the base station, is identical to the downlink path but the other way round. Only some levels and component values differ.
Mini 30mW   User’s Manual  R-Tron., Inc.                                                          15/15 page                          Mini 30 Repeater System User’s Manual  Copyright © 2005 R-TRON, Inc.   All Rights Reserved   Copyright of this manual belongs to R-TRON, Inc. Reproduction, distribution or revision of part or all of contents in this manual in any form without written permission of R-TRON, Inc. is prohibited. The information in this manual is subject to change for the reason of function improvement, design alteration, etc. without any prior notification.

Navigation menu