RAE Systems RM900-01 RAE Mesh module User Manual uesr manual

RAE Systems, Inc RAE Mesh module uesr manual

uesr manual

Download: RAE Systems RM900-01 RAE Mesh module User Manual uesr manual
Mirror Download [FCC.gov]RAE Systems RM900-01 RAE Mesh module User Manual uesr manual
Document ID3184545
Application IDJFRaMe7vzVIlcmTTNJBb8A==
Document Descriptionuesr manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize18.7kB (233753 bits)
Date Submitted2016-11-02 00:00:00
Date Available2016-11-14 00:00:00
Creation Date2016-09-13 09:38:12
Producing SoftwareGPL Ghostscript 9.04
Document Lastmod2016-09-13 09:38:12
Document Titleuesr manual
Document CreatorFreePDF 4.08 - http://shbox.de
Document Author: Jesse.Xu

RAE Systems by Honeywell
RAEMesh Sub 1G wireless
modem RM900
Document Information
Info
Content
Author(s)
Su Feng
Revision
1.0
Document Status
First release
Date
Apr 5, 2016
Distribution
Internal Use Only
Approvals
Name
Date
Signature
James Liu
Zhao Pengjun
Copyright © 2016 Honeywell Analytics, All rights reserved.
Honeywell Confidential and Proprietary
Revision –1.0
Page 1 of 16
RAE Systems by Honeywell
Release Histroy
Rev.
Date
Author
Descripition
1.0
Apr. 5 2016
Su Feng
Initial draft
Copyright © 2016 Honeywell Analytics, All rights reserved.
Honeywell Confidential and Proprietary
Revision –1.0
Page 2 of 16
RAE Systems by Honeywell
Contents
1.
2.
Section1: ......................................................................................................................................... 4
1.1
Summary: .......................................................................................................................... 4
1.2
Key Features: .................................................................................................................... 4
Section2: ......................................................................................................................................... 5
2.1
3.
4.
5.
Technical Description: ..................................................................................................... 5
Section3: ......................................................................................................................................... 6
3.1
Modem Characteristics: ................................................................................................... 6
3.2
PIN Description: ................................................................................................................ 7
3.3
Physical Characteristics:.................................................................................................. 8
Section4: ......................................................................................................................................... 9
4.1
Typical Application diagram: .......................................................................................... 9
4.2
Mounting Information: .................................................................................................... 9
4.3
Antenna Reference: ........................................................................................................ 10
Section5: ....................................................................................................................................... 11
5.1
Certification Information: ............................................................................................. 11
5.2
Modem Information: ...................................................................................................... 11
Copyright © 2016 Honeywell Analytics, All rights reserved.
Honeywell Confidential and Proprietary
Revision –1.0
Page 3 of 16
RAE Systems by Honeywell
1. Section1:
1.1
Summary:
RM900 is a high-sensitivity Sub 1GHz IEEE 802.15.4 module, which offers a
complete microcontroller/transceiver solution containing all hardware features
necessary for development of wireless application. It will replace old Atmel
RM900, which is obsolete now.
1.2
Key Features:
• Frequency Band
779 to 787MHz, 863 to 870MHz, 902 to
928MHz
• Power
1.8 ~ 3.6V, typical 3.3V
• Interfaces
48-pin
• RF
20kbps BPSK/OQPSK in 868MHz, 40kbps
BPSK/OQPSK in 915MHz
• Dimensions
18.8 x 13.5 x 3.0 mm
• Antenna Interface
100-Ohm for balanced output
• Operating Temperature Range -40ºC to +60ºC
• Indicators
Two LEDs, one red, one yellow (DS1, DS2)
• Current Consumption
Sleep current < 40uA
50mA TX @ 10dBm 8MHz Crystal @ 25℃
15mA RX @ 8MHz Crystal
• RF receive sensitivity
-102dBm at 1% packet error rate for a payload
of 20 bytes.
• FCC and CE compliant
• RoHS compliant
Copyright © 2016 Honeywell Analytics, All rights reserved.
Honeywell Confidential and Proprietary
Revision –1.0
Page 4 of 16
RAE Systems by Honeywell
2. Section2:
2.1
Technical Description:
RM900 can work at 868MHz, 1 channel, channel spacing 2MHz. It can also work
at 902 ~ 924MHz, 10 channels, channel spacing 2MHz. Users can change its TX
power, working channel through com tool. RM900 is a high sensitivity IEEE
802.15.4/ZigBee module. A combination of Atmel’s MCU SMD21 and RF
transceiver AT86RF212B, the RM900 offers superior radio performance.
The module contains Atmel’s SAMD21 Cotex-M0 Microcontroller, AT86RF212B
RF transceiver. The module can be easily mounted on a simple 2-layer PCB with
a minimum of required external connection. Neither via-holes nor wires are
allowed on the PCB upper layer in area occupied by the module. As a critical
requirement, RF_GND pins should be grounded via several holes to be located
right next to the pins thus minimizing inductance and preventing both mismatch
and losses.
Copyright © 2016 Honeywell Analytics, All rights reserved.
Honeywell Confidential and Proprietary
Revision –1.0
Page 5 of 16
RAE Systems by Honeywell
3. Section3:
3.1
Modem Characteristics:
3.1.1 Electric Characteristics
Test conditions (unless otherwise stated), Vcc=3.3V, Tamb=25°C
Parameters
Range
Unit
1.8 ~ 3.6
Current Consumption: RX mode
15
mA
@8MHz
Current Consumption: TX mode
50
mA
@10dBm 8MHz
Current Consumption: Sleep mode
30
uA
VCC
Condition
3.1.2 RF Characteristics:
Parameters
Frequency Band
Range
Unit
868/902~924
MHz
Number of Channel
Channel Spacing
1/10
MHz
+10
Transmitter Output Power
Condition
+6
High
dBm
+0
Medium
Low
Receiver Sensitivity
-102
dBm
PER=1%, PSDU=20 byte
On-Air Data Rate
20/40
kbps
O-QPSK
100
Ω
PCB antenna
dBi
Gain
Omni antenna
dBi
Gain
TX output/RX input
Nominal Impedance
Balanced output
Copyright © 2016 Honeywell Analytics, All rights reserved.
Honeywell Confidential and Proprietary
Revision –1.0
Page 6 of 16
RAE Systems by Honeywell
Copyright © 2016 Honeywell Analytics, All rights reserved.
Honeywell Confidential and Proprietary
Revision –1.0
Page 7 of 16
RAE Systems by Honeywell
3.1.3 Module Interfaces characteristics
Parameters
UART Maximum Baud Rate
GPIO Output Voltage
(VOH/VOL)
GPIO Input Voltage
(VIH/VIL)
Real Time Oscillator
Frequency
3.2
Range
Unit
38.4
kbps
0.7VCC/ 0.2VCC
0.7VCC/0.2VCC
32.768
kHz
Condition
-10/ 5mA
VCC = 3.3V
PIN Description:
Copyright © 2016 Honeywell Analytics, All rights reserved.
Honeywell Confidential and Proprietary
Revision –1.0
Page 8 of 16
RAE Systems by Honeywell
PIN description:
PIN
Pin Name
Description
I/O
GPIO_LED_R
General Purpose Digital Output
GPIO_LED_G
General Purpose Digital Output
RESET
Reset Input (active low)
9,22,23
DGND
Digital Ground
13
UART_RXD
UART receive input
14
UART_TXD
UART transmit output
24,25
D_VCC
26
SWDIO
29
SWCLK
34
A_VREF
35
A_GND
40
CTX
41
CRX
43
WakeUp
Wake Up Input(active low)
44,46,48
RF_GND
RF Analog Ground
45
RFP_IO
Differential RF Input/Output
I/O
47
RFN_IO
Differential RF Input/Output
I/O
Others
pins
Digital Supply Voltage (Vcc)
JTAG Serial Wire Debug
Interface
JTAG Serial Wire Debug
Interface
Input/Output reference voltage
for ADC
I/O
I/O
I/O
Analog ground
RF RX/TX Indication to control
an external RF front-end
RF RX/TX Indication to control
an external RF front-end
Reserved
Copyright © 2016 Honeywell Analytics, All rights reserved.
Honeywell Confidential and Proprietary
Revision –1.0
Page 9 of 16
RAE Systems by Honeywell
3.3
Physical Characteristics
Parameter
Size
Operation Temperature Range
Operation Relative Humidity
Range
Range
Unit
18.8 x 13.5 x 3
mm
Condition
-40 to +60
No more than 80%
Mechanical drawing, unit: mm
Top View
Side View
Copyright © 2016 Honeywell Analytics, All rights reserved.
Honeywell Confidential and Proprietary
Revision –1.0
Page 10 of 16
RAE Systems by Honeywell
4. Section4
4.1
Typical Application diagram
PIN
PIN Name
Definition
I/O
RESET
Reset pin, low active
Input
13
UART_RXD
UART TXD pin
Output
14
UART_TXD
UART RXD pin
Input
43
WakeUp
24/25
VCC
9/22/23
GND
Low level wake-up
High level to sleep
Input
Copyright © 2016 Honeywell Analytics, All rights reserved.
Honeywell Confidential and Proprietary
Revision –1.0
Page 11 of 16
RAE Systems by Honeywell
4.2 Mounting Information
The below diagram shows the recommended PCB layout for RM900 module.
Copyright © 2016 Honeywell Analytics, All rights reserved.
Honeywell Confidential and Proprietary
Revision –1.0
Page 12 of 16
RAE Systems by Honeywell
5. Section5
5.1
Certification information:
FCC
FCC Part15C
FCCID: SU3RM900-01
R&TTE
R&TTE , CE-EMC
Refer INTERTEK report
IC
IC ID:20969-RM900
Intrinsic
No on-board voltage enhancement circuits
Safety
Value of the total capacitance Ci≤10uF
Design
Value of the total inductance Li≤5uH
Caution:
This device complies with Part 15 of the FCC Rules / Industry Canada licence-exempt RSS
standard(s). Operation is subject to the following two conditions: (1) this device may not cause
harmful interference, and (2) this device must accept any interference received, including
interference that may cause undesired operation.
Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux
appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions
suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de
l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est
susceptible d'en compromettre le fonctionnement.
Copyright © 2016 Honeywell Analytics, All rights reserved.
Honeywell Confidential and Proprietary
Revision –1.0
Page 13 of 16
RAE Systems by Honeywell
Changes or modifications not expressly approved by the party responsible for compliance could
void the user's authority to operate the equipment.
This equipment has been tested and found to comply with the limits for a Class B digital device,
pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference in a residential installation. This equipment generates
uses and can radiate radio frequency energy and, if not installed and used in accordance with
the instructions, may cause harmful interference to radio communications. However, there is
no guarantee that interference will not occur in a particular installation. If this equipment does
cause harmful interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct the interference by
one or more of the following measures:
—Reorient or relocate the receiving antenna.
—Increase the separation between the equipment and receiver.
—Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected.
—Consult the dealer or an experienced radio/TV technician for help.
Under Industry Canada regulations, this radio transmitter may only operate using an antenna of
a type and maximum (or lesser) gain approved for the transmitter by Industry Canada. To
reduce potential radio interference to other users, the antenna type and its gain should be so
chosen that the equivalent isotropically radiated power
(e.i.r.p.) is not more than that necessary for successful communication.
Conformément à la réglementation d'Industrie Canada, le présent émetteur radio peut
fonctionner avec une antenne d'un type et d'un gain maximal (ou inférieur) approuvé
pour l'émetteur par Industrie Canada. Dans le but de réduire les risques de
brouillage radioélectrique à l'intention des autres utilisateurs, il faut choisir le type
Copyright © 2016 Honeywell Analytics, All rights reserved.
Honeywell Confidential and Proprietary
Revision –1.0
Page 14 of 16
RAE Systems by Honeywell
d'antenne et son gain de sorte que la puissance isotrope rayonnée équivalente
(p.i.r.e.) ne dépasse pas l'intensité nécessaire à l'établissement d'une communication
satisfaisante.
MPE Reminding
To satisfy FCC / IC RF exposure requirements, a separation distance of 20 cm or more should be
maintained between the antenna of this device and persons during device operation.
To ensure compliance, operations at closer than this distance is not recommended.
Les antennes installées doivent être situées de facon à ce que la population ne puisse
y être exposée à une distance de moin de 20 cm. Installer les antennes de facon à ce
que le personnel ne puisse approcher à 20 cm ou moins de la position centrale de l’
antenne.
La FCC des éltats-unis stipule que cet appareil doit être en tout temps éloigné d’au
moins 20 cm des personnes pendant son functionnement.
Information for the OEM Integrators
This device is intended for OEM integrators only. Please see the full grant of equipment
document for restrictions.
Ce dispositif est destiné aux équipementiers et intégrateurs. S'il vous plaît voir la pleine
subvention du document de l'équipement pour les restrictions.
Copyright © 2016 Honeywell Analytics, All rights reserved.
Honeywell Confidential and Proprietary
Revision –1.0
Page 15 of 16
RAE Systems by Honeywell
Label Information to the End User by the OEM or Integrators
If the FCC ID of this module is not visible when it is installed inside another device, then the
outside of the device into which the module is installed must be label with
“Contains FCC ID: SU3RM900-01 and Contains IC: 20969-RM900”.
Si l'ID FCC de ce module est pas visible quand il est installé dans un autre appareil, puis
l'extérieur du dispositif dans lequel le module est installé doit être étiquette avec
"Contient FCC ID: SU3RM900-01 et Contient IC: 20969-RM900".
Copyright © 2016 Honeywell Analytics, All rights reserved.
Honeywell Confidential and Proprietary
Revision –1.0
Page 16 of 16

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.7
Linearized                      : No
Page Count                      : 16
XMP Toolkit                     : XMP toolkit 2.9.1-13, framework 1.6
Producer                        : GPL Ghostscript 9.04
Modify Date                     : 2016:09:13 09:38:12+08:00
Create Date                     : 2016:09:13 09:38:12+08:00
Creator Tool                    : FreePDF 4.08 - http://shbox.de
About                           : 3b58d41a-7bae-11e6-0000-ace5afbc97a.Hm.2016-09-13T09:38:12+08:00
Document ID                     : uuid:3b58d41a-7bae-11e6-0000-ace5afbc97a..c..
Format                          : application/pdf
Title                           : uesr manual
Creator                         : Jesse.Xu
Author                          : Jesse.Xu
EXIF Metadata provided by EXIF.tools
FCC ID Filing: SU3RM900-01

Navigation menu