REMdevice s r l GEGM6 Radio remote control transmitter User Manual Serie move utente v32 en

REMdevice s.r.l. Radio remote control transmitter Serie move utente v32 en

User Manual

Download: REMdevice s r l GEGM6 Radio remote control transmitter User Manual Serie move utente v32 en
Mirror Download [FCC.gov]REMdevice s r l GEGM6 Radio remote control transmitter User Manual Serie move utente v32 en
Document ID3058534
Application IDCbwG3sP+qwNRSJ++c5PsSg==
Document DescriptionUser Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize135.28kB (1691006 bits)
Date Submitted2016-07-12 00:00:00
Date Available2016-07-12 00:00:00
Creation Date2017-12-09 21:30:32
Producing SoftwareGPL Ghostscript 9.18
Document Lastmod2017-12-09 21:30:32
Document TitleSerie-move-utente_v32-en
Document CreatorPDFCreator 2.3.0.103
Document Author: Enrico

USER MANUAL
User Manual
Move series radiocontrols mod. GENESIS, PAIL, BRICK and T
version 3.2
April 2016
contents
Description ................................................................................... 3
move
use
How to use the device correctly and safely ................................. 4
Switching on, Activation, Use, Automatic shutdown ................... 7
Layout and description of controls .............................................. 7
SERIES
RADIOCONTROLS
service functions
Electronic key (LOCK/UNLOCK) .................................................... 8
TWIN auxiliary transmitter unit (FREE) ........................................ 9
CHANGING transmitter FREQUENCY ......................................... 10
Signalling the signal level received ............................................ 13
Wired control option ................................................................. 14
maintenance
Transmitter supply ..................................................................... 16
Recharging the induction accumulators .................................... 17
GENESIS transmitter with removable battery ........................... 18
T transmitter: replacing the lithium battery .............................. 19
Keeping the RC system in proper working order ....................... 21
Transmitter units:
• T 3,5,7 move
• BRICK move
• PAIL move
• GENESIS move
technical specifications
Conformity ................................................................................. 22
Serial Number ............................................................................ 24
Technical specifications ............................................................. 25
Notes and Annexes .................................................................... 27
Warranty terms .......................................................................... 28
WARNING!
Receiver units:
The remote control is to be installed, and subsequently used, by
suitably authorized and qualified personnel only; incorrect installation
or use can result in serious injury or damage to property. Before using
the REMdevice move series radiocontrols, read carefully this instruction
manual and comply with the instructions herein.
• RUBYBOX move
• ECOBOX move
• DIN move
EN
REMdevice® - ITALY
User Manual
Move series radiocontrols mod. GENESIS, PAIL, BRICK and T
version 3.2
April 2016
User Manual
Move series radiocontrols mod. GENESIS, PAIL, BRICK and T
version 3.2
April 2016
How TO USE the DEVICE CORRECTLY and SAFELY
DESCRIPTION
The remote control has been designed strictly for use by qualified
operators only, who are required to first read the instructions on how to
use the device and comply with the safety standards prescribed by the law
in the area where work is carried out.
REMdevice shall not be liable for any bodily injury or damage to property
resulting from:
• misuse or inexpert use of the device
• incorrect wiring or electrical connections
• tampering
• changes to the radiocontrol's design features
• replacement of parts with non-original spare parts
• failure to perform maintenance
• failure to replace worn, faulty or defective parts
• the device being used with its intrinsic safety features disabled or
its original features altered in any way.
The move radio control system consists of one or more transmitter units:
GENESIS move
BRICK move
Warning: This device works using radio signals; it can operate the
machinery it is connected to even if barriers are blocking its line of sight,
such as brick walls, metal or wooden panels, other machinery, equipment,
buildings, vehicles; it is important operators exercise the utmost care when
activating the controls in order to avoid uncontrolled movements.
T 3,5,7 move
PAIL move
Activating the radiocontrol
• Stand with the transmitter unit so that there is a perfectly clear
full line of sight between it and the machinery
• do not linger under overhead loads
• do not operate from an unstable position
• take proper note of the control's identification plates located next
to each button or actuator
• do not press any button or actuator if you do not know exactly
what it does
and of one or more receiver units:
Transmitter units
Transmitter units are made so as to comply with the control functions of
the machine they control. The figures shown are generic.
For your model, please refer to the datasheet attached to this manual.
RUBYBOX move
REMdevice® - ITALY
ECOBOX move
DIN move
REMdevice® - ITALY
User Manual
Move series radiocontrols mod. GENESIS, PAIL, BRICK and T
version 3.2
April 2016
GENESIS move transmitter unit
LED
F1
version 3.2
April 2016
BRICK move transmitter unit
GREEN LED
(ON)
RED LED
(BATT)
User Manual
Move series radiocontrols mod. GENESIS, PAIL, BRICK and T
LED
F2
RED LED
(BATT)
GREEN LED
(ON)
EMERGENCY STOP
BUTTON
START
BUTTON
START
LEVER
EMERGENCY STOP
BUTTON
Figure 1 – GENESIS
Figure 1 – BRICK
T move transmitter unit
EMERGENCY STOP
BUTTON
PAIL move transmitter unit
LED
F1
RED LED
(BATT)
GREEN LED
(ON)
LED F1
LED
F2
RED LED
(BATT)
GREEN LED
(ON)
––
START
LEVER
REMdevice® - ITALY
START
BUTTON
EMERGENCY STOP
BUTTON
Figure 1 – PAIL
Figure 1 – T
REMdevice® - ITALY
User Manual
Move series radiocontrols mod. GENESIS, PAIL, BRICK and T
version 3.2
April 2016
Switching on, Activation, Use, Automatic shutdown
Switching on
If not otherwise stated in the datasheet, the mushroom EMERGENCY STOP
BUTTON
is used to switch the transmitter on and off. To switch on,
rotate and disconnect the mushroom EMERGENCY STOP BUTTON
Check that the GREEN LED (ON) flashes (just once), indicating that the unit
is switched on (see Figure 1, corresponding model).
Activation
Press the START BUTTON or activate the START LEVER or turn the key to
START, depending on the model. The GREEN LED (ON) flashes quickly to
indicate that the unit has been activated.
If, on the other hand, the transmitter bleeps and the RED LED (BATT) comes
on, check no controls are on via the other buttons or actuators that
prevent activation. At the same time, the audible warning of the operating
machine can be heard (if any).
Use
Press the relevant buttons or operate the relevant control actuators for the
operation you want to perform, paying attention to how the machine
behaves.
If you experience any kind of trouble controlling the machine
(for mechanical or electrical reasons or if it is not performing
as you intended in any way), press the EMERGENCY STOP
BUTTON straight away.
Never leave the transmitter unit unattended when it is switched on, even
for just a few seconds. Always switch off the transmitter unit at the end.
Put the transmitter unit away in a safe place where it cannot be reached by
unauthorized personnel; never allow inexperienced personnel to use the
transmitter unit.
User Manual
version 3.2
Move series radiocontrols mod. GENESIS, PAIL, BRICK and T
April 2016
Note: on the GENESIS, PAIL, BRICK and T transmitters, the symbols of the
respective controls are featured on the plates on the product and/or
provided with the unit. If labels or plates other than the ones provided are
used, the symbols must match the machine's functions and movements
exactly and must comply with current regulations.
SERVICE FUNCTIONS
Electronic key
It is possible to prevent unauthorized staff to use the transmitter via the
function:
LOCKING and UNLOCKING the transmitter unit
In page I of the appendix (see page 27 of this manual) the actuators
assigned to this function are shown.
To lock the use of the transmitter, identify actuator Sp3 (or U1)
as specified in the appendix and follow the following
instructions:
a) power up the transmitter using the mushroom EMERGENCY STOP
BUTTON (or using the key selector, where applicable);
b) operate Sp3 (or U1) and operate the START at the same time;
keep on and count 5 beeps and flashes of the F1 LED (if applicable);
after exactly 5 beeps and flashes, release the START and Sp3 (or U1);
c) the GREEN LED (ON) will produce a long flash accompanied by a beep to
confirm that the procedure has been performed correctly.
If the procedure is not performed in this exact sequence or the controls are
held any longer, the operation will be aborted and you will need to repeat
the sequence from the beginning.
If you attempt to activate the transmitter following this operation, the
indicator lights (LEDs) will flash in turn and the transmitter unit's audible
alarm will sound (ring).
To unlock the transmitter, repeat the sequence.
If the transmitter is locked out, you will hear a long ring; if the
transmitter is unlocked, it will play a short melody.
On models with a display, the count will come up on the
display.
Automatic shutdown
If this function is enabled (default factory setting), the transmitter unit will
switch off automatically after approx. 4 minutes of inactivity.
To restart the unit, press the START actuator.
LAYOUT and DESCRIPTION of CONTROLS
The various models differ in terms of the number of controls available and
how they are arranged. A different appendix is associated with each
configuration (see page 27) and is an integral part of this manual.
REMdevice® - ITALY
REMdevice® - ITALY
User Manual
Move series radiocontrols mod. GENESIS, PAIL, BRICK and T
version 3.2
April 2016
User Manual
Move series radiocontrols mod. GENESIS, PAIL, BRICK and T
version 3.2
April 2016
TWIN auxiliary transmitter unit
FREE function
TWIN systems are constituted by two transmitting units: a main and an
auxiliary. To use the system correctly:
o switch on the operating or lifting machine powering the receiver unit;
o switch on one of the two transmitters provided (primary or auxiliary)
and send the START command for approx. 10 seconds.
Once the receiver (RUBYBOX move or ECOBOX move) recognizes the
transmitter, it starts the machine, which sounds:
• ONCE (primary transmitter);
• THREE TIMES (auxiliary transmitter).
From now on, the machine can be controlled only by this transmitter until
power to the receiver unit (RUBYBOX move, ECOBOX move or DIN move) is
cut off or until the FREE command (described in the next paragraph) is
activated.
Only the unit controlling the machine can perform the FREE function that
is freeing the receiver to accept control of the other unit.
In page I of the appendix (see page 23 of this manual) the actuators
assigned to this function are shown.
The other transmitter unit will never be able to take
control of the machine.
The Twin system complies with the EN 60204-32
standard (Safety of machinery) and does not allow
using the two transmitters simultaneously.
There are available two different ways to transfer the machine control
from one transmitter unit to another:
1) Activate the FREE function (as described in the following paragraph)
2) Turn the receiver unit off and on again after a few seconds (normally
the receiver unit is powered by the operating machine: in that case you
may power off and on again after a few seconds directly the machine).
ATTENTION: The machinery may lose power for reasons outside the
operator's control.
In this case, it is possible for a second operator with one of
the two transmitters to take control of the machine if he
happens to press the START button when power is resumed.
The different audible alarm sounds to warn the operators.
REMdevice® - ITALY
To carry out the FREE command, identify the Sp4 (or D1) actuator
as specified in the appendix and follow the following procedure:
a) power up the transmitter using the mushroom EMERGENCY STOP
BUTTON (or using the key selector, where applicable);
b) operate Sp4 (or D1) and operate the START at the same time;
keep that position, paying attention that the beep and the F1 LED (if
any) are activated only once;
after just one flash (or beep), release the START and Sp4 (or D1);
c) the GREEN LED (ON) will produce a long flash accompanied by a short
melody to confirm that the procedure has been performed correctly.
If the procedure is not performed in this exact sequence or the controls are
held any longer, the operation will be aborted and you will need to repeat
the sequence from the beginning.
In case of error, the LEDs will flash alternately and the transmitter will
sound.
On models with a display, all stages are shown on the display and the
message "FREE" comes up to confirm the operation.
CHANGING transmitter FREQUENCY
There is no need to open either the transmitter unit or receiver unit to
change frequency. Locate actuator Sp4 (or lever D1, as specified in greater
detail on page I of the appendix on page 19 of this manual) and proceed as
follows:
a) power up the transmitter using the mushroom EMERGENCY STOP
BUTTON (or using the key selector, where applicable);
b) operate Sp4 (or D1) and operate the START at the same time;
keep on and count 5 beeps and flashes of the F1 LED (if applicable, on
the left);
after exactly 5 beeps and flashes, release START and Sp4 or D1;
c) the Green LED flashes accompanied by a short melody to confirm that
you have entered the band/frequency change menu;
d) activate Sp4 or D1 again together with START; keep on and count 3
beeps and flashes of the F1 LED (if any, on the left); after exactly 3
beeps and flashes, release START and Sp4 or D1;
10
REMdevice® - ITALY
User Manual
version 3.2
Move series radiocontrols mod. GENESIS, PAIL, BRICK and T
April 2016
e) the Green LED flashes accompanied by a short melody to confirm that
you have entered the menu via which you can change the channel.
User Manual
Move series radiocontrols mod. GENESIS, PAIL, BRICK and T
Models: EC
CH1
433,0625
CH6
433,1875
CH11
433,3125
CH16
433,4375
CH21
433,5625
CH26
433,6875
From the channel change menu, you can:
• Activate Sp4 or D1 to get to the CHANNEL - function (unit);
• Activate Sp3 or U1 to get to the CHANNEL + function (unit);
• Activate START + Sp4 or D1 to get to the
CHANNEL -10 function (tens);
• Activate START + Sp3 or U1 to get to the
CHANNEL +10 function (tens);
• Once you have set the value you want for the frequency, press the
EMERGENCY STOP BUTTON and reset it;
• Hold the START button down for a few seconds and keep holding it
down until the machine starts.
CH2
433,0875
CH7
433,2125
CH12
433,3375
CH17
433,4625
CH22
433,5875
CH27
433,7125
CH3
433,1125
CH8
433,2375
CH13
433,3625
CH18
433,4875
CH23
433,6125
CH28
433,7375
CH4
433,1375
CH9
433,2625
CH14
433,3875
CH19
433,5125
CH24
433,6375
CH29
433,7625
CH5
433,1625
CH10
433,2875
CH15
433,4125
CH20
433,5375
CH25
433,6625
CH30
433,7875
Models: EC (…continues)
Band 434.050 – 434.790 MHz
CH31
434,0625
CH36
434,1875
CH41
434,3125
CH46
434,4375
CH51
434,5625
CH56
434,6875
The set channel is shown with the tens first (number of times the red LED
flashes) and then the units (number of times the green LED flashes).
The frequency band to be set varies depending on the laws and
standards in the country where the product is due to be used.
In order to operate, the radio control system with the remote-controlled
machine, must respect the laws and the regulations in the country where
it is used.
CH32
434,0875
CH37
434,2125
CH42
434,3375
CH47
434,4625
CH52
434,5875
CH57
434,7125
CH33
434,1125
CH38
434,2375
CH43
434,3625
CH48
434,4875
CH53
434,6125
CH58
434,7375
CH34
434,1375
CH39
434,2625
CH44
434,3875
CH49
434,5125
CH54
434,6375
CH59
434,7625
CH35
434,1625
CH40
434,2875
CH45
434,4125
CH50
434,5375
CH55
434,6625
CH60
434,7875
Models: EC (…continues)
Band 869.700 – 870.000 MHz
CH61
869,7125
CH66
869,8375
CH71
869,9625
REMdevice S.r.L can not be held responsible if the radio controls are set to
prohibit frequencies in the country of use.
11
April 2016
Band 433.050 – 433.790 MHz
If you stay in state b or d for anything other than the stated time, the
operation is aborted and you will need to repeat the sequence from the
beginning.
On models with a display, the display will show the count, the number of
the set channel and advise you that you have entered the various menus.
REMdevice® - ITALY
version 3.2
12
CH62
869,7375
CH67
869,8625
CH72
869,9875
CH63
869,7625
CH68
869,8875
CH64
869,7875
CH69
869,9125
CH65
869,8125
CH70
869,9375
REMdevice® - ITALY
User Manual
Move series radiocontrols mod. GENESIS, PAIL, BRICK and T
version 3.2
April 2016
Models: FCC-IC
Band 902.5 – 915 MHz
CH1
902,5
CH6
905,0
CH31
907,5
CH16
910,0
CH21
912,5
CH2
903,0
CH7
905,5
CH12
908,0
CH17
910,5
CH22
913,0
CH3
903,5
CH8
906,0
CH13
908,5
CH18
911,0
CH23
913,5
CH4
904,0
CH9
906,5
CH14
909,0
CH19
911,5
CH24
914,0
CH5
904,5
CH10
907,0
CH15
909,5
CH20
912,0
CH25
914,5
Wired control option
The wired control connection is an option available only for transmitters
GENESIS and PAIL with receivers ECOBOX and RUBYBOX.
Activating the wired control
• Switch off both the transmitter (GENESIS or PAIL) and receiver (ECOBOX
or RUBYBOX).
• Remove the protection caps from the connectors.
• Connect the cable supplied paying attention to the white mark on the
connectors.
Models: FCC-IC (…continues)
Band 915.0 – 927.5 MHz
CH26
915,0
CH31
917,5
CH36
920,0
CH41
922,5
CH46
925,0
CH51
927,5
CH27
915,5
CH32
918,0
CH37
920,5
CH42
923,0
CH47
925,5
CH28
916,0
CH33
918,5
CH38
921,0
CH43
923,5
CH48
926,0
CH29
916,5
CH34
919,0
CH39
921,5
CH44
924,0
CH49
926,5
User Manual
version 3.2
Move series radiocontrols mod. GENESIS, PAIL, BRICK and T
April 2016
To activate this function:
a) power up the transmitter using the mushroom EMERGENCY STOP
BUTTON (or using the key selector, where applicable);
b) activate Sp3 or U1 together with START; keep on and count 2 beeps
and flashes of the F1 LED (if any);
If no signalling takes place, "FAIL" is displayed.
CH30
917,0
CH35
919,5
CH40
922,0
CH45
924,5
CH50
927,0
GENESIS transmitter unit
PAIL transmitter unit
ECOBOX receiver unit
RUBYBOX receiver unit
Signalling the signal level received
Available only for models with the display option (GENESIS, PAIL and
BRICK), reporting shows the signal intensity that the base unit receives the
transmitter with and takes place through 15 bars that light up in sequence.
REMdevice® - ITALY
13
14
REMdevice® - ITALY
User Manual
Move series radiocontrols mod. GENESIS, PAIL, BRICK and T
• Fix the cable using the Velcro strap supplied:
o on the transmitter handle
o on the receiver output cable
version 3.2
April 2016
User Manual
Move series radiocontrols mod. GENESIS, PAIL, BRICK and T
E xample of the fixed cable on:
PAIL transmitter unit
ECOBOX receiver unit
version 3.2
April 2016
90°
MAINTENANCE
Transmitter supply
The transmitter supply varies according to the models and version
purchased.
• Power the receiver and start the transmitter.
Wired control operation
When the wired control is working, radio transmission is disabled and data
is transmitted via the wire in both directions (control and data feedback
functions) as per normal operation.
Supply of the transmitter takes place via the power cable that recharges
the internal accumulators too.
Deactivating the wired control
Model
GENESIS
PAIL
BRICK
T3,5,7
Power supply types
Internal accumulators with induction recharge or
rechargeable removable battery
Internal accumulators with induction recharge
Internal accumulators with induction recharge
Long-life non-rechargeable internal lithium battery
• Switch off both the transmitter (GENESIS or PAIL) and receiver (ECOBOX
or RUBYBOX).
• Disconnect the cable supplied removing the Velcro straps.
• Reposition the protection caps on the connectors.
• Power the receiver and start the transmitter.
WARNING:
Pull the plugs with the cable perpendicular to the socket. If the cable is
bent in any direction, the plug does not separate from the socket!
(See the figure on the next page)
REMdevice® - ITALY
15
16
REMdevice® - ITALY
User Manual
Move series radiocontrols mod. GENESIS, PAIL, BRICK and T
version 3.2
April 2016
User Manual
Move series radiocontrols mod. GENESIS, PAIL, BRICK and T
April 2016
the RED LED (BATT) on the transmitter unit flashes to
indicate that the accumulators are being charged properly
recharging is controlled electronically:
the recharge time is controlled automatically
Recharging the induction accumulators
In the GENESIS, PAIL and BRICK models, the accumulators are housed
inside the transmitter device and are recharged using an exclusive
patented electromagnetic induction system involving no metal electrical
contacts or connecting cables.
version 3.2
• when the RED LED (BATT) on the transmitter unit is steadily lit, it means
the batteries have finished charging.
With new and fully charged batteries, the transmitter unit has a runtime
(for continuous duty) of around 30 hours at 20°C.
Under normal operating conditions, you will only need to charge the
batteries once a week (during the weekend, for example).
The electronic charge status control means you can leave the device on the
charger base for long periods of time without doing any damage to the
batteries.
It is normal for the peg sticking out of the charger and the
hollow on the underside of the transmitter unit to heat up
while the batteries are charging.
If the accumulators are completely discharged but
efficient, 30 minutes' recharge time will be enough to
guarantee the radio control operation for 8 hours.
LED
(ON)
CONTACTLESS
RECHARGE
UNIT
Figure 2
ATTENTION: the contactless charger the system comes with
must be located in a safe, dry place out of direct sunlight and
sheltered from rain; it must be plugged into the mains so that
the outlet is easy to reach at all times.
The transmitter shows the accumulator discharge limit value has been
reached when the GREEN LED (ON), the RED LED (BATT) and a long sound
are activated all at the same time. Recharge the batteries as soon as
possible:
• check that the (ON) LED is lit on the charger (see Figure 2 on page 9), (it
means it is being powered correctly);
• switch the transmitter off as described above;
• place the transmitter in the appropriate housing on the contactless
recharge unit, paying attention the peg in the centre of the recharge
base enters the hole in the bottom of the transmitter;
• if ON, the transmitter automatically deactivates when resting on the
recharge base;
Do NOT open the charger to attempt repairs: if there is a fault,
use the services of authorized personnel or contact REMdevice
directly.
REMdevice® - ITALY
18
17
Unplug the charger when it is not in use.
GENESIS transmitter with removable battery
The innovative 24/7 non-stop system guarantees continuous operation also
during the replacement of the removable external battery.
The radio control is fitted with two external and a group of internal
batteries. The external removable battery gives about 20 hours' operation
autonomy, while the internal group gives autonomy for 1.5 hours.
Therefore, the internal group allows the unit to work without the
removable battery while this recharges. The removable battery can then be
replaced when the RED LED (BATT) lights up, without interrupting the radio
control operation.
REMdevice® - ITALY
User Manual
Move series radiocontrols mod. GENESIS, PAIL, BRICK and T
version 3.2
April 2016
Indications
User Manual
Move series radiocontrols mod. GENESIS, PAIL, BRICK and T
version 3.2
April 2016
T transmitter: replacing the lithium battery
The RED LED (BATT) on the transmitter flashes when:
• the external battery is low
• the external battery has been removed or reinserted incorrectly
• the contacts of the external battery are dirty, oxidized or damaged
NOTE
This happens also when the radio control is OFF and for
about 20 days, that is until the internal group is fully
discharged.
The battery is inside the transmitter: to replace it, it is necessary to open
the unit. This operation must be carried out in a clean place, with no
humidity and only by specialized personnel, authorized by REMdevice.
• Remove the 8 screws and open the transmitter lid
• Remove the connector and replace the battery with a new one
LID
No. 8
LOCKING
SCREWS
If the internal group is completely discharged, the removable external
battery must be inserted for the whole time required for the recharge;
during this time the radio control can anyway be used.
EXTERNAL
BATTERY
(REMOVABLE)
NON-RECHARGEABLE
BATTERY
UNIVERSAL
CHARGER for the
EXTERNAL BATTERY
(REMOVABLE)
For further information on the Universal Charger, check the Instruction
Manual supplied with this product.
Attention: this charger is NOT waterproof; keep it in a cool and dry place
and recharge at ambient temperature.
The external (removable) battery lasts ≈ 22 hours at 20°C
The internal battery lasts: ≈ 1 hour at 20°C
• Use the sticker applied to the battery body peeling off the protective
film and removing the residues of the old adhesive.
• Before closing the keypad, be careful in folding the red and black
wires back against the battery and prevent them from being crushed
while closing.
Strong shocks to the transmitter and its battery can permanently
damage the battery.
Risk of fire, explosion and serious burns.
The lithium battery is not rechargeable: do not dismantle, recharge,
apply voltage, short-circuit, expose to high temperatures or flames,
do not burn or immerse in water.
If the unit is not used for over 3 months, proceed to "awake"
the battery by repeating the transmitter's START procedure
until stabilized, that is until the transmitter is stabilized and
remains ON without showing any error of low battery. The operation
normally lasts a few minutes.
The charge of the internal battery is sufficient to completely
recharge and replace the external battery.
REMdevice® - ITALY
BATTERY
CONNECTOR
19
20
REMdevice® - ITALY
User Manual
version 3.2
Move series radiocontrols mod. GENESIS, PAIL, BRICK and T
April 2016
The life expectancy of the battery can be reduced if subjected to extreme
temperatures. Batteries must be stored in cool, clean and ventilated rooms
with a temperature of between 10°C and 30°C.
If batteries are stored for over 8 years they might experience a loss of
performance.
Spent batteries must not be disposed of in the environment or together with the
normal domestic waste. Batteries must be disposed of in compliance with local
regulations, using the waste disposal service available in the area.
Keeping the radio control system in proper working order
Preventive maintenance and routine checks
Clean the transmitter unit at regular intervals to stop sediment building up
and becoming extremely hard to remove later on and/or obscuring graphic
symbols showing what functions are assigned to the control buttons.
Should symbols become illegible or come off, you must replace them with
new labels.
In induction recharge models, clean the cavity at the
bottom of the units periodically to prevent debris build-up.
Do not use solvents to clean the devices. Do not immerse
the transmitter unit in water.
Check that the transmitter unit's seal is perfectly
watertight, check for cracks in the housing and make sure the rubber on
buttons or control actuators is not damaged in any way. The ingress of
liquid can seriously damage or compromise the proper operation of the
electrical circuits inside the radio control.
Non-routine maintenance and any repairs needed must be carried out only
by specialist personnel authorized by REMdevice.
Above all, replacing accumulators with unsuitable parts can result in a risk
of explosion.
User Manual
version 3.2
Move series radiocontrols mod. GENESIS, PAIL, BRICK and T
April 2016
Reset the EMERGENCY STOP BUTTON to continue.
Once you have reactivated the transmitter unit, press one button or
actuator at a time and check that the machine performs the operation
indicated by the relevant symbol.
NEVER use the device if the EMERGENCY STOP BUTTON is not in working
order. This pushbutton has to be working properly to ensure that all
machine operations are stopped immediately and the remote control
system is disabled. If this pushbutton is not in perfect working order, or
even if it is only partially broken, system safety is compromised, meaning
the unit is no longer complying with the regulations and operators are
exposed to serious danger.
TECHNICAL SPECIFICATIONS
Conformity
All move series radio controls operating in the frequency band 433.050 434.790 MHz and/or 869.700 - 870 MHz comply with the essential
requirements and the other pertinent regulations set in directive R&TTE
99/5/EC. The EC declaration of conformity attached contains the list of the
harmonised regulations the radio controls comply with (as far as it is
applicable).
All the move series radio controls operating in the frequency band 902 928 MHz comply with the essential requirements of the following
standards:
• FCC (Federal Communication Commission) Part 15
• IC (Industry Canada) RSS-102
Press the EMERGENCY STOP BUTTON (see Figure 1) and check the radio
control has switched off and deactivated.
To carry on with the testing procedure, reset the EMERGENCY STOP
BUTTON by turning it roughly a ¼ turn until it clicks, then activate the
START control on the transmitter unit again.
Press a button or operate a machine control actuator associated with a
movement and, keeping it held down, press the EMERGENCY STOP
BUTTON at the same time: the machine must stop immediately!
REMdevice® - ITALY
21
Transmitter Unit
Checking that the EMERGENCY STOP BUTTON and all
functions are working properly
22
BRICK move
FCC ID = RTF-BRBPM6
IC number = 11555A-BRBPM6
PAIL move
FCC ID = RTF-PABPM6
IC number = 11555A-PABPM6
GENESIS move
FCC ID = RTF-GEGM6
IC number = 11555A-GEGM6
T move
FCC ID = RTF-TTM6
IC number = 11555A- TTM6
REMdevice® - ITALY
User Manual
Move series radiocontrols mod. GENESIS, PAIL, BRICK and T
version 3.2
April 2016
User Manual
Move series radiocontrols mod. GENESIS, PAIL, BRICK and T
version 3.2
April 2016
Receiver Unit
Serial Number
ECOBOX move
FCC ID = RTF-EBEBM6
IC number = 11555A-EBEBM6
RUBYBOX move
FCC ID = RTF-RBRBM6
IC number = 11555A-RBRBM6
FCC ID = RTF-DDM6
IC number = 11555A-DDM6
DIN move
It appears on the ID plates of the receiver units:
Federal Communications Commission (FCC)
This device complies with part 15 of the FCC Rules.
Operation is subject to the following two conditions:
(1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including
interference that may cause undesired operation.
Any changes or modifications not expressly approved by the party
responsible for compliance could void the user’s authority to operate the
equipment.
BRICK move
GENESIS move
Industry Canada (IC)
T 3,5,7 move
PAIL move
This device complies with RSS-210 of the Industry Canada Rules.
Operation is subject to the following two conditions:
(1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including
interference that may cause undesired operation.
and on the receiver units:
ECOBOX move
DIN move
RUBYBOX move
REMdevice® - ITALY
23
24
REMdevice® - ITALY
User Manual
Move series radiocontrols mod. GENESIS, PAIL, BRICK and T
version 3.2
April 2016
TECHNICAL SPECIFICATIONS
Full-Duplex multi-band operating frequency:
433.050 – 434.790 MHz/ Channel spacing 25kHz/ No. of channels 60
869.700 – 870.000 MHz/ Channel spacing 25kHz/ No. of channels 12
902 – 928 MHz/ Channel spacing 500kHz/ No. of channels 51
GENESIS
Hamming code distance: > 4
Response time to commands: 20 ms min, 80 ms max (according to the model)
Active emergency stop command response time: 20 ms
Command passive emergency response time: 1 s
PL
Category
SIL
(EN ISO 13849-1)
≈ 22 hrs
≈ 1 hour
non-stop
24/7
≈ 20 mins
Type: NB-7L – Li-Ion
7.4V 1000 mAh
Type: 3 × Size AAA
1.2V Ni-MH
GENESIS
≈ 30 mins
NOT available
Type: 3 × Size AA
1.2V Ni-MH
PAIL
≈ 30 mins
NOT available
Type: 3 × Size AA
1.2V Ni-MH
BRICK
≈ 30 mins
NOT available
Type: 3 × Size AA
1.2V Ni-MH
NOT available
T 3,5,7
≈ 30 hrs
NOT available
NOT available
Type: Size D
Lithium 3.6V 19 Ah
NOT available
≈ 30 hrs
NOT available
≈ 30 hrs
NOT available
Receiver unit
Weight [g] [lb]
(depending on the configurations)
1580
930
470
350
Internal battery
(not rechargeable)
≈ 1000 hrs
Housing protection rating: IP 65 - Material: PA6 GF
GENESIS
PAIL
BRICK
T 3,5,7
Internal battery
(rechargeable)
SIL
(EN IEC 62061)
Transmitter unit
Dimensions [mm]
[in]
(L×H×P)
(L×W×H)
310 × 193 × 163 (12.2 × 7.6 × 6.42)
200 × 135 × 130 (7.87 × 5.31 × 5.12)
97 × 210 × 44
(3.82 × 8.27 × 1.73)
83 × 174 × 42
(3.27 × 6.85 × 1.65)
External battery
(removable)
≈ 30 hrs
PL
Range: 100 m (≈330 ft)
Operating and storage temperature: -20°C to +70°C (-4°F to +158°F)
Model
Advance
warning time
Model
The frequency band varies depending on the standards in the
country where the product is due to be used.
Command
STOP
Button/Lever (UMFS)
Joystick (UMFS)
User Manual
version 3.2
Move series radiocontrols mod. GENESIS, PAIL, BRICK and T
April 2016
Battery low advance warning and operating autonomy at 20°C (68°F)
3.48
Radiofrequency receiver: Single Chip
Antenna (according to model):
integrated or external (with automatic selection)
Rp1, Rp2 relay contact capacity: 8A (DC1/AC1)* / 115V (RUBYBOX and ECOBOX)
Command relay contact capacity: 4A (DC1/AC1)* / 115V (RUBYBOX and DIN)
Stop relay contact capacity: 4A (DC1/AC1)* / 115V
same current can be supported also in category DC13 (inductive load)
 * the
connecting a diode in parallel to the load. For use in category AC15, we
2.05
recommend connecting a suitable RC circuit in parallel to the load for extra
voltage damping. (Ref. IEC/EN60947).
1.04
0.77
Power supply (depending on model):
DC 12-24V ±25% or AC 24-115V ±10%
RUBYBOX move: waterproof enclosure for external installation
Material: PA6 GF V0 - Degree of protection: IP65
Dimensions: 166 × 279 × 91 mm (L×W×H) 6.53 × 10.98 × 3.58 in
ECOBOX move: waterproof enclosure for external installation
Material: PA6 GF V0 - Degree of protection: IP65
Dimensions: 129 × 178 × 51 mm (L×W×H) 2.08 × 7.01 × 2.01 in
DIN move: ModulBox housing to be fitted on DIN EN 50022 rail
Material: ABS - Degree of protection: IP20
Dimensions: 158 × 90 × 75 mm (L×W×H) 6.22 × 3.54 × 2.95 in
REMdevice® - ITALY
25
26
REMdevice® - ITALY
User Manual
Move series radiocontrols mod. GENESIS, PAIL, BRICK and T
version 3.2
April 2016
User Manual
Move series radiocontrols mod. GENESIS, PAIL, BRICK and T
version 3.2
April 2016
WARRANTY TERMS
REMdevice covers the device with a 12-month warranty.
The date of the transport document is used as the start date of the warranty
period.
The warranty is valid only for devices affected by defects in manufacturing. The
radio control must NOT have undergone attempted repairs, been tampered
with or had parts replaced by personnel who have not been authorized by
REMdevice.
The warranty shall be voided in the event of misuse or incorrect installation.
Devices under warranty must be repaired at an authorized support centre or at
REMdevice's own facility.
Parts affected by defects in manufacturing will be replaced free of charge; this
does not include transport costs for sending and returning the device.
The warranty does not cover wear parts and batteries.
REMdevice shall not accept claims for compensation for downtime since
machinery is required to have its own manual controls.
REMdevice shall not be liable for damage, loss or theft to/of new or repaired
devices, or devices due to be repaired, while in transit.
REMdevice shall not perform work (under warranty or outside warranty) on
devices with missing serial numbers or without previous arrangements having
been made with the person requesting the work.
NOTES:
INSERT HERE
Manufacturer: REMdevice® S.r.L
Email: info@remdevice.com
http://www.remdevice.com
THE ANNEXES
REMdevice® S.r.L
via Alfredo Munari n. 72
36055 Nove (VI)
ITALY
WITH THE
TEL +39 0424 500 262
FAX +39 0424 508 631
REMOTE CONTROL
Copyright © 2016 – REMdevice® S.r.L – All rights reserved.
While the information herein has been checked thoroughly for accuracy and
completeness, REMdevice disclaims liability for any errors or omissions.
REMdevice reserves the right to edit the specifications described herein at any
time without prior notice.
No part of the information herein may be reproduced, transmitted, transcribed,
stored in a retrieval system, or translated into any language in any form,
without the prior written permission of REMdevice ® S.r.L
SPECIFICATIONS
REMdevice® - ITALY
27
28
REMdevice® - ITALY

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : No
Encryption                      : Standard V4.4 (128-bit)
User Access                     : Print, Print high-res
Page Count                      : 14
Page Layout                     : SinglePage
Page Mode                       : UseNone
XMP Toolkit                     : XMP toolkit 2.9.1-13, framework 1.6
About                           : uuid:12cd4dcb-1459-11e6-0000-01749d8fd936
Producer                        : PDFCreator 2.3.0.103; modified using iTextSharp 5.2.1 (c) 1T3XT BVBA
Keywords                        : 
Modify Date                     : 2016:05:04 15:39:09+02:00
Create Date                     : 2016:05:04 15:39:07+02:00
Creator Tool                    : PDFCreator 2.3.0.103
Document ID                     : uuid:12cd4dcb-1459-11e6-0000-01749d8fd936
Format                          : application/pdf
Title                           : Serie-move-utente_v32-en
Creator                         : Enrico
Description                     : 
Author                          : Enrico
Subject                         : 
EXIF Metadata provided by EXIF.tools
FCC ID Filing: RTF-GEGM6

Navigation menu