RF Controls IN610 RF ID Interrogator User Manual User Guide
RF Controls, LLC RF ID Interrogator User Guide
Contents
- 1. Users_Guide 610
- 2. Users_Guide A-200 and A-202
Users_Guide A-200 and A-202
User Guide SASL™ (Signal Acquisition & Source Location unit) RF Controls Intelligent Tracking and Control System (ITCS™) ITCS-A-2xx Family Models ITCS-A-200 ITCS-A-202 SASL Installation Guide V2.13 - Part # ITCS-A-100-001v1.13 Sept 2012 Introduction This SASL™ User Guide provides the basic information needed to install an individual SASL antenna unit. This guide is not intended to provide instructions for installing, configuring and calibrating the RF Controls Intelligent Tracking and Control System (ITCS™). Detailed instructions are provided in the Technical Manual (ITCS-A-100-002) and Programmer’s Reference Guide (ITCS-A-100-003). INTENDED AUDIENCE This guide is intended for those who will install and set up the RF Controls SASL (Signal Acquisition and Source Location) unit. Before attempting to install, configure and operate this product, you should be familiar with the following: Windows based software installation and operation Device communication parameters including Ethernet and serial communications RFID reader configuration including antenna placement and RF Parameters Electrical and RF safety procedures. CONTENTS 1. 2. 3. 4. 5. SASL overview Installation Software Specifications Safety instructions FCC NOTICE This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. CONTACT INFORMATION RF Controls, LLC th 1141 S. 7 Street St. Louis MO 63104-3623 USA Phone: +1 314 571-6200 Fax: +1 314 832-0029 Web site: http://www.rf-controls.com SASL Installation Guide V2.13 - Part # ITCS-A-100-001v1.13 Sept 2012 SASL OVERVIEW SASL is a multi-protocol, multi-regional Radio Frequency Signal Acquisition & Source Location unit, which is used to Identify and locate RFID tags operating in the UHF 860 – 960 MHz frequency band. A number of SASL units may be used together with an ITCS Location Processor to form an Intelligent Tracking and Control System (ITCS). SASL comprises an embedded multi-protocol, multi-regional RFID reader/writer transceiver connected to the patented steerable phased array antenna system. SASL is designed to operate from AC mains power and communicates with a host computer using standard Ethernet TCP/IP and UDP protocol. Figure 1 illustrates the two versions of SASL currently available. Both versions are equipped with identical RFID reader and Array Controller. ITCS-A-200 is constructed using eight Bi-directional Electronically Steerable Phased Arrays (BESPA™) arranged to provide a single array with a circularly polarized gain of 11.6dBi. ITCS-A-202 is constructed using four BESPAs arranged to provide a single array with a circularly polarized gain of 7.6dBi. The particular units used in an installation will depend on the system design and determined by a qualified applications engineer. The two models may be intermixed as required in a single ITCS system. ITCS-A-200 ITCS-A-202 Figure 1 SASL (Signal Acquisition and Source Location) units SASL Installation Guide V2.13 - Part # ITCS-A-100-001v1.13 Sept 2012 INDICATOR LIGHTS Reader Indicator Lights The SIRIT INfinity 610 is equipped with four status indicators located on the top of the enclosure. From left to right, these LEDs provide indication according to the following table: Position Number Indication Color/State Off Power Activity User Status Amber AmberFlashing Indication Power Off Boot loader executing Linux Initializing Green Off Green Green-Flash Unit operational RF Off TX Active Tag detect Amber Antenna Check Failed Amber Off Amber Green-Flash User defined OK Firmware update GPIO activity Red Fault Note that when the SIRIT reader is performing power on auto-test, the indicator lights will flash momentarily. Figure 2 SIRIT RFID Reader Indicator Lights. SASL Installation Guide V2.13 - Part # ITCS-A-100-001v1.13 Sept 2012 Installation MECHANICAL INSTALLATION Each model of the ITCS-A-2xx family of SASL units is mounted slightly differently. SASL units weigh up to 100 lbs (46.3 kg), so it is important to ensure that the structure, to which the SASL is to be attached, is of sufficient strength. The SASL may be ceiling mounted, wall mounted or attached to a suitable stand. A safety cable rated at three (3) times the hanging weight of the SASL and associated hardware must be secured to a separate fixture and attached to the SASL mounting bracket. When mounting the SASL as a stand-alone unit, make sure that it is mounted the correct way up as indicated by information in the Technical Manual, for the specific SASL. If the SASL is one of several and is part of an ITCS network, then orient each SASL according to the ITCS system installation drawings. If in doubt contact a member of our technical support team. ITCS-A-200 The ITCS-A-200 SASL is provided in its standard configuration with a mounting bracket for installation in a landscape orientation. When mounting the SASL refer to figure 3. Consult the Technical Manual, for further information. Contact a member of our technical support team for more information. ITCS-A-202 The ITCS-A-202 SASL is only mounted in a landscape orientation because the array is symmetrical there is no benefit to mounting the array in a portrait fashion. When mounting the SASL refer to figure 3. Consult the Technical Manual, for further information. Contact a member of our technical support team for more information. When mounting the SASL as a stand-alone unit, make sure that it is mounted the correct way up as indicated by information in the Technical Manual, for the specific SASL. If the SASL is one of several and is part of an ITCS network, then orientate each SASL according to the ITCS system installation drawings. If in doubt contact a member of our technical support team. SAFETY WARNING The ITCS-A-200 SASL weighs approximately 100 lbs. (49 kg), and ITCS-A-202 weighs approximately 50 lbs (23kg). These units should only be installed using suitable safety and lifting equipment. Ensure that the wall fixings or mounting hardware is suitably rated. SASL Installation Guide V2.13 - Part # ITCS-A-100-001v1.13 Sept 2012 ELECTRICAL INSTALLATION Electrical installation requires the connection of two plugs: AC Mains Input AC mains input is an IEC connector as shown in figure 3. Connect the provided IEC mains cord to the power supply and plug it in to a suitable mains outlet. Note that the mains outlet must be located in close proximity to the SASL and must be accessible to enable easy disconnection of the mains supply to the SASL in case of emergency or when servicing. The form and location of the AC mains input is the same on the ITCS-A-200 and ITCS-A-202. Ethernet The Ethernet LAN connection uses the industry standard RJ-45 connector. A suitable Ethernet cable fitted with an RJ-45 plug is connected to the SASL Array Controller box as shown in figure 3. The SASL is factory programmed with a fixed IP address which is shown on the label adjacent to the Ethernet connector. The form and location of the Ethernet connection Input is the same on the ITCS-A-200 and ITCS-A-202. Figure 3 ITCS-A-200 and ITCS-A-202 Power and Ethernet Connections are similar in form and location. SASL Installation Guide V2.13 - Part # ITCS-A-100-001v1.13 Sept 2012 WARNING The SASL is not user serviceable. Dis-assembly or opening the SASL will cause damage to its operation, will void any warranty and may invalidate the FCC type approval NON IONIZING RADIATION This unit incorporates a Radio Frequency Transmitter and should therefore be installed and operated so as to avoid exposure of any persons to unsafe emissions. The FCC requires that any antenna, which includes the SASL, be mounted so that a separation distance of at least 23cm is provided from all persons. See FCC Radiation Exposure Statement in the Safety Instructions section of this guide. NOTICE FOR EUROPEAN INSTALLERS The Installer shall ensure that he is familiar with any restrictions of the local EU Member State on the use of this device and ensure compliance! Examples may include: restrictions on geographic location or only for indoor use etc. Due to differences between ETSI and FCC frequency bands, “Phase Ranging” Techniques are not available with the ETSI version of the SASL. USABLE FREQUENCY RANGE IN USA AND CANADA In USA and Canada this device is factory programmed to operate in ISM 902MHz – 928MHz band SASL Installation Guide V2.13 - Part # ITCS-A-100-001v1.13 Sept 2012 MULTIPLE SASL UNITS CONFIGURED AS AN ITCS Figure 4 shows how two or more ITCS-A-2xx SASL units may be connected via an Ethernet network to an ITCS Location Processor. One Location Processor and multiple distributed SASLs operate collaboratively to form RF Controls’ Intelligent Tracking and Control System (ITCS™). In this example two SASL units have been attached to the network. Combinations of the various model SASL units may be mixed and matched as required to suit a particular installation. The RF Controls Technical Manual provides details on how to install, configure and calibrate an ITCS. The Programmers Reference Guide provides details of the Application Program Interface (API) used by the ITCS. Figure 4 Intelligent Tracking and Control System comprising a number of SASL units connected via an Ethernet Network to an ITCS Location Processor SASL Installation Guide V2.13 - Part # ITCS-A-100-001v1.13 Sept 2012 Software The SASL is provided with a basic test program on a CD, to run on a Microsoft™ Windows® equipped Personal Computer. The program enables you to carry out a number of basic tests. See the Technical Manual, ITCS-A-100-002 for further instruction on Software usage. APPLICATION INTERFACE The SASL uses an International Standard, Application Program Interface (API) as defined in ISO/IEC 24730-1. Further details of the API and commands are contained in the Programmer’s Reference Guide. SASL Installation Guide V2.13 - Part # ITCS-A-100-001v1.13 Sept 2012 Specifications General ITCS-A-200 ITCS-A-202 UHF band: 860 – 960 MHz1 Adjustable from 0.1 to 4 Watts EiRP Frequency RF Radiated Output Power Regulatory Compliance FCC, CFR47 Part 15.247 EN 302 208, EN 301 489-3, EN 301 489-1, EN55022, EN55024, EN 60950-1:2005 Reading/writing Protocols FCC ID Application Interface ISO18000-6C / EPC UHF Gen 2 EM 4122 (TTO) WFQITCSA200 WFQITCSA202 ISO/IEC 24730-1 Environmental Operating Temperature Storage Temperature Relative Humidity Dimensions Weight +14 to +130 °F (-10 to +55°C) -40 to +85ºC 5 to 95% non-condensing 68 x 36 x 5” (170 x 90 x 13 cm)) 100 lbs (46 kg) 36in x 36in x 5in (90 x 90 x 13 cm) 54 lbs (25 kg) Ethernet LAN Connector Ethernet Indicators RJ-45 10/100 BaseT Yellow – link operational Green – network traffic detected Pin 1 TXD+ Pin 2 TXD Pin 3 RXD+ Pin 4 NC Signals Pin 5 Pin 6 Pin 7 Pin 8 NC RXD NC NC Power Supply Input Connector Voltage Frequency Current IEC/EN 60320 C14 90 – 265 Volts AC 47 – 63 Hz 3A Antenna Gain2 (circularly polarized) 11.6 dBi2 7.4 dBi2 The SASL uses the SIRIT INfinity 610 RFID reader which will be factory set at time of shipping, to suit the country of installation and use. Nominal maximum value. Precise gain depends on transmit frequency SASL Installation Guide V2.13 - Part # ITCS-A-100-001v1.13 Sept 2012 10 Safety Instructions This unit emits Radio Frequency non-ionizing radiation. The installer must ensure that the antenna is located or pointed such that it does not create an RF field in excess of that permitted by the Health and Safety Regulations applicable to the country of installation. Setting RF Output Power Enter the desired RF output power as a percentage of the maximum power into the Set Power box. Click the set Power button. Note: the actual maximum Radiated RF Power is factory set to comply with the radio regulations in the country of use. In the USA and Canada this is 4 Watts EiRP and under EN 302 208 this is 2 Watts ERP (3.2 W EiRP). FCC Radiation Exposure Statement The antenna used on this equipment must be installed to provide a separation distance of at least 23cm from all persons and must not be co-located or operated in conjunction with another antenna or transmitter. FCC Part 15 Notice This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. FCC and Industry Canada Modification Warning Statement Modification of this device is strictly prohibited. Any modifications to the factory hardware or software settings of this device will void all warranties and be deemed non-compliant with FCC and Industry Canada Regulations. La modification de ce dispositif est strictement interdite. Toutes les modifications apportées au matériel d'usine ou les paramètres du logiciel de cet appareil annulera toutes les garanties et sera considérée comme non conforme aux normes FCC et d'Industry Canada. Industry Canada Statement This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. Cet appareil est conforme aux normes d'Industrie Canada exempts de licence RSS (s). Son fonctionnement est soumis aux deux conditions suivantes: (1) cet appareil ne doit pas provoquer d'interférences, et (2) cet appareil doit accepter toute interférence, y compris les interférences qui peuvent provoquer un fonctionnement non désiré de l'appareil. Power Disconnect Device The plug on the power supply cord is intended to be the power disconnect device. The power source (socket or outlet) shall be located near the equipment and shall be easily accessible. SASL Installation Guide V2.13 - Part # ITCS-A-100-001v1.13 Sept 2012 11 Statement of Compliance with R&TTE directive RF Controls, LLC hereby declares that it’s ITCS-A-200, and ITCS-A-202 products are in compliance with the essential requirements and other relevant provisions of European Directive 1999/5/EC. The original Certificate of Conformity is available at www.rf-controls.com The SASL products and individual BESPA components are protected by one or more US and International Patents pending. The “RF Controls” logo, and the words “RF Controls, Identify, Locate, Track”, “ITCS”, “SASL” and “BESPA” are registered Trademarks of RF Controls, LLC. RF Controls, LLC th 1141 S. 7 Street St. Louis MO 63104-3623 USA Phone: Fax: e-mail: Web site: +1 314 571 6200 +1 314 832 0029 e-mail: techsupport@rf-controls.com http://www.rf-controls.com SASL Installation Guide V2.13 - Part # ITCS-A-100-001v1.13 Sept 2012 12
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : No Page Count : 12 Language : en-US Tagged PDF : Yes Title : User Guide Author : Chris Turner Subject : SASL User Guide Creator : Microsoft® Word 2010 Create Date : 2012:12:19 10:42:14-06:00 Modify Date : 2012:12:19 10:42:14-06:00 Producer : Microsoft® Word 2010EXIF Metadata provided by EXIF.tools