RF WINDOW ICS-F0837 ICS-Digital Relay User Manual ICS F0837 v1 1

RF WINDOW Co.,Ltd. ICS-Digital Relay User Manual ICS F0837 v1 1

user manual

Download: RF WINDOW ICS-F0837 ICS-Digital Relay User Manual ICS F0837 v1 1
Mirror Download [FCC.gov]RF WINDOW ICS-F0837 ICS-Digital Relay User Manual ICS F0837 v1 1
Document ID1243958
Application IDxDxtpUBMR+TuqlELoS0fRw==
Document Descriptionuser manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize59.32kB (741535 bits)
Date Submitted2010-02-22 00:00:00
Date Available2010-04-08 00:00:00
Creation Date2010-02-04 17:53:26
Producing SoftwareAcrobat Distiller 7.0 (Windows)
Document Lastmod2010-02-04 17:59:19
Document TitleMicrosoft Word - User_Manual_ICS-F0837_v1.1.doc
Document CreatorPScript5.dll Version 5.2.2
Document Author: Owner

FCC ID : X4O-ICS-F0837
ATTACHMENT E.
- USER MANUAL -
HCT CO., LTD.
SAN 136-1, AMI-RI, BUBAL-EUP, ICHEON-SI, KYOUNGKI-DO, 467-701, KOREA
TEL:+82 31 639 8517 FAX:+82 31 639 8525 www.hct.co.kr
Report No. : HCTR1002FR09
1/1
ICS-F0837
User Manual

2010. 1
ICS Repeater ICS-W0837B User Manual
[ Table of Contents ]
1.
System Overview ................................................................................................. 10
2.
System Network Configuration ............................................................................ 11
2.1. Service for Network.............................................................................................. 11
2.2. NMS Network....................................................................................................... 12
3.
System Specification............................................................................................ 13
3.1. System ................................................................................................................. 13
3.1.1. System Specification ....................................................................................... 13
3.2. System Configuration........................................................................................... 17
3.3. Environment Specification.................................................................................... 18
3.4. Mechanical Specification...................................................................................... 18
4.
Housing................................................................................................................ 19
4.1. Housing Configuration ......................................................................................... 19
4.1.1. System ............................................................................................................ 19
4.1.2. System Block Plan .......................................................................................... 21
4.1.3. System External Connector Plan .................................................................... 22
5.
Main Module Configuration .................................................................................. 24
5.1. ICM (Interference Cancellation Module) .............................................................. 24
5.1.1. ICM 24
5.2. Filter ..................................................................................................................... 25
5.2.1. Donor & Service Duplexer............................................................................... 25
5.3. Dual HPA ............................................................................................................. 26
5.3.1. Dual HPA......................................................................................................... 26
ICS-F0837 User manual/Confidential & Proprietary
RF Window Co., Ltd. |
ICS Repeater ICS-W0837B User Manual
5.4. Power Supply....................................................................................................... 27
5.4.1. Power Supply .................................................................................................. 27
5.5. INTERFACE......................................................................................................... 28
5.5.1. INTERFACE .................................................................................................... 28
5.5.2. VFD30
5.5.3. KEY-PAD ......................................................................................................... 33
6.
Main features of
system operation and monitoring program ............................. 34
6.1. Download Feature................................................................................................ 34
6.1.1. Objective ......................................................................................................... 34
6.1.2. Procedure........................................................................................................ 34
6.2. ICS Gain Setup Feature....................................................................................... 34
6.2.1. Objective ......................................................................................................... 34
6.2.2. Procedure........................................................................................................ 34
6.2.3. Others ............................................................................................................. 35
6.3. Total Power Limit.................................................................................................. 35
6.3.1. Objective ......................................................................................................... 35
6.3.2. Procedure........................................................................................................ 35
6.4. Auto Recovery ..................................................................................................... 36
6.4.1. Objective ......................................................................................................... 36
6.4.2. Procedure........................................................................................................ 36
6.5. Up Link Auto Shutdown Mode.............................................................................. 36
6.5.1. Objective ......................................................................................................... 36
6.5.2. Procedure........................................................................................................ 36
6.6. NMS Operation .................................................................................................... 37
ICS-F0837 User manual/Confidential & Proprietary
RF Window Co., Ltd. |
ICS Repeater ICS-W0837B User Manual
6.6.1. Alarm Monitoring feature................................................................................. 37
6.6.2. LED Feature.................................................................................................... 37
7.
GUI ....................................................... 오류! 책갈피가 정의되어 있지 않습니다.
7.1. Program Overview ................................ 오류! 책갈피가 정의되어 있지 않습니다.
7.2. PC Requirement ................................... 오류! 책갈피가 정의되어 있지 않습니다.
7.3. How to Use ........................................... 오류! 책갈피가 정의되어 있지 않습니다.
7.3.1. Program Installation ......................... 오류! 책갈피가 정의되어 있지 않습니다.
7.3.2. Program Start ................................... 오류! 책갈피가 정의되어 있지 않습니다.
7.3.3. Window description .......................... 오류! 책갈피가 정의되어 있지 않습니다.
7.3.4. Communication Setup...................... 오류! 책갈피가 정의되어 있지 않습니다.
7.3.5. Repeater Status ............................... 오류! 책갈피가 정의되어 있지 않습니다.
7.3.6. Repeater Monitoring......................... 오류! 책갈피가 정의되어 있지 않습니다.
7.3.7. Repeater Control.............................. 오류! 책갈피가 정의되어 있지 않습니다.
7.3.8. Control Item...................................... 오류! 책갈피가 정의되어 있지 않습니다.
7.3.9. Firmware Download ......................... 오류! 책갈피가 정의되어 있지 않습니다.
8.
7.3.10.
Data Debugging ........................ 오류! 책갈피가 정의되어 있지 않습니다.
7.3.11.
Feedback Signal Status Check . 오류! 책갈피가 정의되어 있지 않습니다.
System Installation and Setup ............................................................................. 38
8.1. Installation............................................................................................................ 38
8.1.1. Configuration................................................................................................... 38
8.1.2. Installation ....................................................................................................... 38
8.1.3. Check List before operation ............................................................................ 39
8.1.4. RF Monitor Port............................................................................................... 39
8.2. Process of ICS Repeater setup and installation .................................................. 40
ICS-F0837 User manual/Confidential & Proprietary
RF Window Co., Ltd. |
ICS Repeater ICS-W0837B User Manual
8.3. Fault / Alarm Handling.......................................................................................... 41
8.3.1. Down Link / Up Link ALARM Handling............................................................ 41
8.3.2. Environment Alarm.......................................................................................... 42
9.
Manufacturer Information..................................................................................... 43
ICS-F0837 User manual/Confidential & Proprietary
RF Window Co., Ltd. |
ICS Repeater ICS-W0837B User Manual
[List of Figures]
[FIGURE - 1] SYSTEM NETWORK CONFIGURATION 1 ................................................... 11
[FIGURE - 2] SYSTEM NETWORK CONFIGURATION 2 ................................................... 11
[FIGURE - 3] NMS NETWORK CONFIGURATION.............................................................12
[FIGURE - 4] FRONT AND SIDE VIEW...............................................................................19
[FIGURE - 5] REAR VIEW...................................................................................................20
[FIGURE - 6] SYSTEM BLOCK PLAN.................................................................................21
[FIGURE - 7] SYSTEM EXTERNAL CONNECTORS..........................................................22
[FIGURE - 8] DOWN LINK/UP LINK ICM ............................................................................24
[FIGURE - 9] DONOR & SERVICE DUPLEXER .................................................................25
[FIGURE - 10] DOWN LINK PAU ........................................................................................26
[FIGURE - 11] POWER SUPPLY.........................................................................................27
[FIGURE - 12] INTERFACE.................................................................................................28
[FIGURE - 13] RCU VFD MENU TREE...............................................................................30
[FIGURE - 14] KEY-PAD......................................................................................................33
[FIGURE - 15] GUI MAIN WINDOW...................... 오류! 책갈피가 정의되어 있지 않습니다.
[FIGURE - 16] GUI COMMUNICATION SETUP.... 오류! 책갈피가 정의되어 있지 않습니다.
[FIGURE - 17] GUI COMMUNICATION STATUS WINDOW .. 오류! 책갈피가 정의되어 있지
않습니다.
[FIGURE - 18] GUI SYSTEM STATUS .................. 오류! 책갈피가 정의되어 있지 않습니다.
[FIGURE - 19] GUI PSU STATUS.......................... 오류! 책갈피가 정의되어 있지 않습니다.
[FIGURE - 20] GUI DOWN LINK SETUP STATUS 오류! 책갈피가 정의되어 있지 않습니다.
[FIGURE - 21] GUI UP LINK SETTING STATUS .. 오류! 책갈피가 정의되어 있지 않습니다.
[FIGURE - 22] GUI WCDMA(3G) CONTROL WINDOW 오류! 책갈피가 정의되어 있지 않습
ICS-F0837 User manual/Confidential & Proprietary
RF Window Co., Ltd. |
ICS Repeater ICS-W0837B User Manual
니다.
[FIGURE - 23] FIRMWARE DOWNLOAD WINDOW..오류! 책갈피가 정의되어 있지 않습니
다.
[FIGURE - 24] GUI DEBUG WINDOW .................. 오류! 책갈피가 정의되어 있지 않습니다.
[FIGURE - 25] SIGNAL STATUS WINDOW .......... 오류! 책갈피가 정의되어 있지 않습니다.
[FIGURE - 26] PROCESS OF ICS REPEATER SETUP AND INSTALLATION ...................40
ICS-F0837 User manual/Confidential & Proprietary
RF Window Co., Ltd. |
ICS Repeater ICS-W0837B User Manual
[ List of Tables ]
[TABLE - 1] RF SYSTEM SPECIFICATION.........................................................................16
[TABLE - 2] SYSTEM CONFIGURATION............................................................................18
[TABLE - 3] ENVIRONMENT SPECIFICATION...................................................................18
[TABLE - 4] MECHANICAL SPECIFICATION......................................................................18
[TABLE - 5] MODULES........................................................................................................21
[TABLE - 6] SYSTEM EXTERNAL CONNECTORS ............................................................22
[TABLE - 7] MECHANICAL SPECIFICATION......................................................................23
[TABLE - 8] INTERFACE FEATURES .................................................................................29
[TABLE - 9] RCU STATUS CONTROL DETAILS.................................................................33
[TABLE - 10] KEY FEATURE...............................................................................................33
[TABLE - 11] GUI PC REQUIREMENT.................. 오류! 책갈피가 정의되어 있지 않습니다.
[TABLE - 12] REPEATER STATUS DETAILS ........ 오류! 책갈피가 정의되어 있지 않습니다.
[TABLE - 13] SYSTEM MONITORING .................. 오류! 책갈피가 정의되어 있지 않습니다.
[TABLE - 14] PSU MONITORING.......................... 오류! 책갈피가 정의되어 있지 않습니다.
[TABLE - 15] DOWN LINK MONITORING............. 오류! 책갈피가 정의되어 있지 않습니다.
[TABLE - 16] UP LINK MONITORING ................... 오류! 책갈피가 정의되어 있지 않습니다.
[TABLE - 17] SYSTEM CONTROL ITEM............... 오류! 책갈피가 정의되어 있지 않습니다.
[TABLE - 18] DOWN LINK CONTROL ITEM ......... 오류! 책갈피가 정의되어 있지 않습니다.
[TABLE - 19] UP LINK CONTROL ITEM ............... 오류! 책갈피가 정의되어 있지 않습니다.
[TABLE - 20] SYSTEM CONFIGURATION..........................................................................38
[TABLE - 21] AC CONNECTOR PIN ASSIGN .....................................................................38
[TABLE - 22] SYSTEM CONNECTION PORT.....................................................................39
[TABLE - 23] RF MONITOR PORT......................................................................................39
ICS-F0837 User manual/Confidential & Proprietary
RF Window Co., Ltd. |
ICS Repeater ICS-W0837B User Manual
[TABLE - 24] DOWN LINK / UP LINK ALARM HANDLING .................................................42
[TABLE - 25] ENVIRONMENT ALARM................................................................................42
ICS-F0837 User manual/Confidential & Proprietary
RF Window Co., Ltd. |
ICS Repeater ICS-W0837B User Manual
1. System Overview
ICS-F0837 is a digital repeater that provides optimized service with ICS (Interference
Cancellation System) to make the most efficient way to enhance WCDMA network.
ICS-F0837 consists of the same construction as normal RF repeater except DSP (Digital
Signal Processing) part and it can overcome oscillation problem caused by lack of the
isolation level between donor and coverage antennas.
ICS-F0837 can automatically compensate rapidly-changing input signals including echo
feedback signals caused by multi-path environment and it has various advantages for
operation and maintenance.
ICS-F0837 consists of ICM (Interference Cancellation Module) that cancels feedback
signals, RF signal amplifier, MCU (Main Control Unit), and modem (optional) to operate with
NMS(Network Management System).
ICS-F0837 User manual/Confidential & Proprietary
RF Window Co., Ltd. |
10
ICS Repeater ICS-W0837B User Manual
2. System Network Configuration
2.1. Service for Network
ICS-F0837 can provides Cell Coverage to a Node-B with using PAU and it is for
expansion of WCDMA Cell Coverage.
The System Network Configuration of ICS-F0837 is shown as below
Wireless
γ
α
Repeater
α
β
Repeater Cell
T1/E1
[Figure - 1] System Network Configuration 1
Wireless
Repeater
Repeater
γ
α
Optic Fiber
β
α
Repeater Cell
T1/E1
[Figure - 2] System Network Configuration 2
ICS-F0837 User manual/Confidential & Proprietary
RF Window Co., Ltd. |
11
ICS Repeater ICS-W0837B User Manual
Input level of ICS-F0837 is air interfaced with RF signal of WCDMA transferred from
Node-B and mobile through Donor and Service Antenna. The system consists of ICM that
cancels feedback signals, RF signal amplifier, monitoring and control processor, and
modem to operate with NMS (Optional).
The system has features that the Node-B RF signal through the donor antenna, ICM and
amplified by PAU of down link to pass the signals to service antenna. Also, it takes the
mobile input signal through service antenna, ICM and amplifier to pass the signals to donor
antenna. ICM consists of two parts, RF part and Digital part and ICM cancels feedback
signals for DL and UL. DL HPA consists of AMP block that amplifies RF signals and
Controller block that monitor and controls Amp block.
2.2. NMS Network
ICS-F0837 can be connected with WRCS which has been already operating.
The Connection of between WRCS and ICS-F0837 meets the standard of service
provider.
[Figure - 3] NMS Network Configuration
ICS-F0837 User manual/Confidential & Proprietary
RF Window Co., Ltd. |
12
ICS Repeater ICS-W0837B User Manual
3. System Specification
3.1. System
3.1.1. System Specification
1) WCDMA
Parameter
Down Link
Up Link
Frequency Range
869MHz ~ 894MHz
824MHz ~ 849MHz
Channel Band Width
5MHz (3.84MHz/Carrier)
Flatness
3dB p-p
Input Power Range
-63dBm ~
Remark
-50dBm/Total(Under)
-33dBm/Carrier
Output Power
+37dBm/Total
+27dBm/Total
System Gain
70dB~100dB
70dB~100dB
Gain Control Range
30dB @1dB/Step
System Delay
< 8㎲
Waveform Quality
EVM ≤ 12.5%
PCDE
< -35dB
Frequency Stability
< 0.01ppm
VSWR
< 1.5 : 1
TX/RX Isolation
> 110dBc
Noise Figure
Out-Band ACLR
< 7dB
@ Max Power
@Max. Gain
≥ 45dBc @Fc±5MHz
≥ 50dBc @Fc±10MHz
2nd Harmonics
> 80dBc
Impedance
50ohm
ICS-F0837 User manual/Confidential & Proprietary
RF Window Co., Ltd. |
13
ICS Repeater ICS-W0837B User Manual
a) ICS General Performance Specification
Parameter
Condition
Specification
DL, UL
6 us
Target Gain ±1dB
< 10 Sec
Isolation Sensing
-20dB < Gain < 20dB
Accuracy ±3
Range
(-10dB < Gain < 10dB)
Accuracy ±1
Cancellation
Window Length
Gain Re-Tracking
Time after reset
Remark
b) ICS Fading Performance Specification
Gain
Feddback Condition
(Multi-path 10)
G = I + 20dB
Static
G = I + 10dB
5Hz
G=I
10Hz
Specification
EVM : < 12.5%
Gain Variation : < ±2dB
Remark
No Fading
EVM : < 12.5%
General
Gain Variation : < ±2dB
Operating
EVM : < 12.5%
Gain Variation : < ±2dB
ICS-F0837 User manual/Confidential & Proprietary
Fast Fading
RF Window Co., Ltd. |
14
ICS Repeater ICS-W0837B User Manual
2) CDMA
Parameter
Down Link
Up Link
Frequency Range
869MHz ~ 894MHz
824MHz ~ 849MHz
Channel Band Width
1.23MHz (Carrier)
Flatness
3dB p-p
Input Power Range
-63dBm ~
Remark
-50dBm/Total(Under)
-33dBm/Carrier
Output Power
+37dBm/Total
+27dBm/Total
System Gain
70dB~100dB
70dB~100dB
Gain Control Range
30dB @1dB/Step
System Delay
< 10㎲
Waveform Quality
Rho>0.97
Frequency Stability
0.05ppm 이하
VSWR
< 1.5 : 1
TX/RX Isolation
> 110dBc
Noise Figure
< 7dB
@ Max Power
@Max. Gain
Fo±750kHz: 45dBc
Spurious Emissions
Fo±1.98MHz: 60dBc
Fo±3.125MHz:
-13dBm/100KHz
2nd Harmonics
> 80dBc
Impedance
50ohm
a) ICS General Performance Specification
ICS-F0837 User manual/Confidential & Proprietary
RF Window Co., Ltd. |
15
ICS Repeater ICS-W0837B User Manual
Parameter
Cancellation
Window Length
Gain Re-Tracking
Time after reset
Isolation Sensing
Range
Condition
Specification
DL, UL
6 us
Target Gain ±1dB
< 10 Sec
10dB < Gain < 10dB
Accuracy ±1
Remark
b) ICS Fading Performance Specification
Gain
Feddback Condition
(Multi-path 10)
G = I + 10dB
Static
G=I
5Hz
Specification
Rho>0.97
Gain Variation : < ±2dB
Remark
No Fading
Rho>0.97
General
Gain Variation : < ±2dB
Operating
[Table - 1] RF System Specification
ICS-F0837 User manual/Confidential & Proprietary
RF Window Co., Ltd. |
16
ICS Repeater ICS-W0837B User Manual
3.2. System Configuration
Parameter
Filter Type
Donor Antenna
Specification
Remark
Duplexer
Service Antenna Duplexer
Power Supply
RF Connector Type
AC Input Voltage : 100VAC ~ 240VAC(50Hz/60Hz)
DC Input Voltage : +24VDC(+21VDC ~ 29.5VDC)
Antenna : 7/8 Inch Din Type Female
AC: MS3102A-20-18M(9Pin)
Power Connector Type
(Option:-AC: MS3102A22S-2P(3Hole male)
-DC: MS3102A20-8P(6Hole male)
Size
305mm(W) X 565mm(H) X 194mm(D)
weight
30Kg (Under)
Power Consumption
200W (Under)
Chasing level
IP65
Operation Temperature
-30°C ~ +55°C(95%RH)
Storage Temperature
-40°C ~ +80°C(95%RH)
OMC
Include Monitoring-Control-Alarm
Box panel for security of
repeater
Local/Remote Control
With bracket
NEBS
GR-63-
CORE Section4.1.2
NEBS
GR-63-
CORE Section4.1.2
NEBS
GR-63-
CORESection4.1.1
Proportional
USB Port at local, Modem(Option)
Optional (Mute be)
Remote Access
Software Setting
Under Windows
ICS-F0837 User manual/Confidential & Proprietary
RF Window Co., Ltd. |
17
ICS Repeater ICS-W0837B User Manual
Modem for remote
Include / one package
[Table - 2] System Configuration
3.3. Environment Specification
Item
Specification
AC Power
AC 100 ~ 260V
DC In Power
Remark
DC Input Voltage :
+24VDC(+21VDC ~ 29.5VDC)
Consumption power
Under 200W
Operating Temperature
-30°C ~ +55°C
Operating Humidity
5% ~ 95%
Storage temperature
-40 ~ +80°C(5~95% RH)
Ingress protection
IP65
Option
[Table - 3] Environment Specification
3.4. Mechanical Specification
Item
Details
Size
305(W) X 565(H) X 194(D)
Weight
Under 30Kg
Convection type
Natural convection
Mounting
Wall & poll (modified based on user request)
Cabinet type
Outdoor (compliant with IP 65)
[Table - 4] Mechanical Specification
ICS-F0837 User manual/Confidential & Proprietary
RF Window Co., Ltd. |
18
ICS Repeater ICS-W0837B User Manual
4. Housing
4.1. Housing Configuration
4.1.1. System
[Figure - 4] Front and Side View
ICS-F0837 User manual/Confidential & Proprietary
RF Window Co., Ltd. |
19
ICS Repeater ICS-W0837B User Manual
[Figure - 5] Rear View
ICS-F0837 User manual/Confidential & Proprietary
RF Window Co., Ltd. |
20
ICS Repeater ICS-W0837B User Manual
4.1.2.System Block Plan
②
①
⑤
④
③
[Figure - 6] System Block Plan
No.
Module Name
ICM
INTERFACE (with Modem)
DUPLEXER (TOP)
DUAL HPA (BOTTOM)
PSU
UPS Interface
[Table - 5] Modules
ICS-F0837 User manual/Confidential & Proprietary
RF Window Co., Ltd. |
21
ICS Repeater ICS-W0837B User Manual
4.1.3. System External Connector Plan
①
③
④
②
[Figure - 7] System External Connectors
No.
Name
AC Input Port
Bluetooth Modem port
Donor Antenna Port
Service Antenna Port
[Table - 6] System External Connectors
ICS-F0837 User manual/Confidential & Proprietary
RF Window Co., Ltd. |
22
ICS Repeater ICS-W0837B User Manual
Item
Specification
Size
305mm(W) X 565mm(H) X 194mm(D)
Material
Aluminum(AL5052, AL6063) for rust protection
Cooling
Natural Convection with Heat Sink
Locks
2 EA on the side of cabinet
Antenna
1. Location : 2 Ports at the under of housing
Port
2. Connector Type : DIN Type
Modem
1. Location : 1 Port at the lower of housing
Port
2. Connector Type : SMA Type
Ground
M5 2Hole
Environmental
Condition
1. Water proof : outdoor type
2. ∆T : within 20℃
3.Vibration : 1G, 10~150Hz, 0.1oct/min, XYZ
[Table - 7] Mechanical Specification
ICS-F0837 User manual/Confidential & Proprietary
RF Window Co., Ltd. |
23
ICS Repeater ICS-W0837B User Manual
5. Main Module Configuration
5.1. ICM (Interference Cancellation Module)
ICM is located between Antenna connector and Dual HPA. It is designed to resolve the
problems caused by near-far among operators and LNA built-in to amplify a low noise and
make satisfied stop band rejection. It operates to transmit signals to Dual HPA and to
maintain signal regularly input to final amplifier after determining gain to need for system
after conversing signal processed from DSP to frequency. It is also operated the function of
Remote Control Unit through INTERFACE.
5.1.1. ICM
[Figure - 8] Down Link/Up Link ICM
ICS-F0837 User manual/Confidential & Proprietary
RF Window Co., Ltd. |
24
ICS Repeater ICS-W0837B User Manual
5.2. Filter
It is 25MHz Band Pass Filter(DL:869~894,UL:824~849) and consists of Service and
Donor. Service Duplexer has 40dB Coupler to monitor Output power and Donor Duplexer
has 30dB Coupler to monitor Input power. Hence it can enable to measure the signal level
and to observe its specification.
5.2.1. Donor & Service Duplexer
[Figure - 9] Donor & Service Duplexer
ICS-F0837 User manual/Confidential & Proprietary
RF Window Co., Ltd. |
25
ICS Repeater ICS-W0837B User Manual
5.3. Dual HPA
Down link PAU receives the signal from ICM and amplifies it finally. This is designed to
keep up the stable output power of system in order to satisfy electrical specification of
system output power.
It is a Linear Amp with output power 8W(total power) in down link, 1W in up link (total
power) and executes Drive Amp feature simultaneously while Gain is 47dB in Down Link,
33dB in Up Link.
Input Voltage is 27VDC and has alarm feature for over power, over temperature, and
VSWR. It has the same mount hole which can be applied for the same specification and
configuration according to output power amount (8W/1W) and HPA manufacturer.
5.3.1. Dual HPA
[Figure - 10] Down Link PAU
ICS-F0837 User manual/Confidential & Proprietary
RF Window Co., Ltd. |
26
ICS Repeater ICS-W0837B User Manual
5.4. Power Supply
PSU is designed to input AC 100~260V and to output DC +27V and +12V.
+27V and Battery is designed for the Pin short protection by inferior and can provide a
stable power supply. It also has Back-Up Battery terminals so that the service can be
provided even if there is power shortage.
5.4.1. Power Supply
[Figure - 11] Power Supply
ICS-F0837 User manual/Confidential & Proprietary
RF Window Co., Ltd. |
27
ICS Repeater ICS-W0837B User Manual
5.5. INTERFACE
User can monitor and control the repeater by VFD and Keypad. Interface board consists
of 40Pin connector for communication with ICM, 16pin connector for communication with
Dual HPA, 24pin connector for communication with Interface board receives electrical
power from PSU and distributed the power to all of active module except Dual HPA. It also
can communicate with all of active module. Debug port is designed based on USB
connection
5.5.1. INTERFACE
UPS Alarm
INTERFACE
POWER
INTERFACE
VFD
HPA
INTERFACE
KEY-PAD
USB
MODEM ANTENNA
PORT
LED
BLUETOOTH ANTENNA
PORT
ICM
INTERFACE
UPS Alarm
INTERFACE
[Figure - 12] INTERFACE
ICS-F0837 User manual/Confidential & Proprietary
RF Window Co., Ltd. |
28
ICS Repeater ICS-W0837B User Manual
Term
Feature
VFD
Monitor and check the status
KEY-PAD
Check and control the status
LED
Check the status of Module
Modem Ant.
Modem Antenna connection Port
Bluetooth Ant.
Bluetooth Modem Antenna connection Port
USB
GUI Port, System check with USB, PC
Power Supply
ICM, INTERFACE, reverse Dual HPA power
PSU Status
Status information of Power Supply Unit
Module Interface
ICM, Dual HPA, Modem
Power supply/ Data Interface
[Table - 8] INTERFACE Features
ICS-F0837 User manual/Confidential & Proprietary
RF Window Co., Ltd. |
29
ICS Repeater ICS-W0837B User Manual
5.5.2.2.
RCU status control menu
RCU status control menu
Item
Details
“ Fwd Status
” ICS
Remark
“
: [Normal] “
“ Fwd Status
“
“ OUTPWR : 000dBm”
“ Fwd Status
“ INPWR
: -000dBm”
“ Fwd Status
“ ISO.
“FWD Status”
“
: 000dB”
“ Fwd Status
“
“ GAINMODE : [GAIN]dB>”
“ Fwd Status
“ GAIN
“ATTN
[OFF]/[GAIN]
Down Link GAIN Setup Mode
Down Link Attenuator Setup Mode
“
“
: [Normal]”
“ Rvs Status
” ICS
Down Link GAIN setup Mode
: [Normal]”
“ Fwd Status
“ LOW
“
: 000dB>”
“ Fwd Status
“ HIGH
“
: 000dB>”
“ Fwd Status
“RVS Status”
“
“
: [Normal] “
“ Rvs Status
“
“ OUTPWR : 000dBm”
“ Rvs Status
“ INPWR
: -000dBm”
“ Rvs Status
“ ISO.
“
“
: 000dB”
“ Rvs Status
“
“ GAINMODE : [GAIN]dB>”
“ Rvs Status
“ GAIN
“
: 000dB>”
Up Link GAIN Setup Mode
[OFF]/[GAIN]/[BAL]
Up Link GAIN Setup Mode
ICS-F0837 User manual/Confidential & Proprietary
RF Window Co., Ltd. |
31
ICS Repeater ICS-W0837B User Manual
“ Rvs Status
“ ATTN
: 000dB>”
“ Rvs Status
“ BAL
“
: 000dB>”
“ Rvs Status
“ HIGH
“
Up Link Attenuator Setup Mode
Up Link Balance Setup Mode
“
: [Normal]”
“ Fwd AMP Status “
“ OVERPWR : [NORMAL] ”
“ Fwd AMP Status “
“ HI. TEMP : [NORMAL]”
“ Fwd AMP Status “
“FWD AMP Status”
“ VSWR
: [NORMAL]”
“ Fwd AMP Status “
“ DC
: [NORMAL]”
“ Fwd AMP Status “
“ Device : [NORMAL]”
“RVS AMP Status”
“Environment”
“ Fwd AMP Status “
Down Link Amplifier On/Off Setup
“ Amp
Mode
: [ ON ]>”
“ Rvs AMP Status “
“Amp
: [ON]>”
“ Environment
“ DOOR
”
: [NORMAL]”
“ Environment
“ BATT
”
: [NORMAL]”
“ Environment
“ DC
”
: 000 ℃”
“ Environment
“ AC
”
: [OPEN]”
“ Environment
“ TEMP
”
: [NOTUSE]>”
“ Environment
”
“ FAMODE : [MANUAL]>”
“ Environment
“ FAN
Up Link Amplifier On/Off Setup Mode
Battery Use Setup Mode
(Unistall, 29V embedded)
FA Mode Setup Mode
Manual (FA1~FA4), Auto
”
: [MANUAL]>”
ICS-F0837 User manual/Confidential & Proprietary
RF Window Co., Ltd. |
32
ICS Repeater ICS-W0837B User Manual
“ Environment
“ SLANT
”
Slop Sensor Setup Reset
: [RESET]>”
“ Environment
“ SLANT
”
: [NORMAL]>”
[Table - 9] RCU Status Control Details
5.5.3. KEY-PAD
M enu
Up
D ow n
E nter
ESC
[Figure - 14] KEY-PAD
KEY-PAD uses 5 keys as above. Each meaning and operation is as below. The setup
Mode is only in P#02 and it can change a mode by setup.
In P#02, a menu which can be setup is displayed as ‘>’
Key
Menu
Up
Down
Enter
Esc
Step
Status Mode
Setup Mode
P#00
Move to P#01
N/A
P#01
Move to P#00
N/A
P#02
Move to P#00
Move to P#00
P#00
N/A
N/A
P#01
Upper menu of P#01
N/A
P#02
Upper menu of P#02
On or Increase
P#00
N/A
N/A
P#01
Lower menu of P#01
N/A
P#02
Lower menu of P#02
Off or Decrease
P#00
Password window if press for 2 sec
N/A
P#01
Move to P#02
N/A
P#02
switch over to MoPe on setting menu
Setting Value
P#00
N/A
N/A
P#01
Move to P#00
N/A
P#02
Move to P#01
Cancel setiting
[Table - 10] Key Feature
ICS-F0837 User manual/Confidential & Proprietary
RF Window Co., Ltd. |
33
ICS Repeater ICS-W0837B User Manual
6. Main features of system operation and monitoring program
6.1. Download Feature
6.1.1. Objective
To changed and updated features of system operation and monitoring program.
6.1.2. Procedure
CPU (in ICM) performs download remotely through TCP/IP function of modem installed in
a repeater.
6.2. ICS Gain Setup Feature
6.2.1. Objective
To keep up the fixed value of Gain desired by users for Down Link Path and Up Link Path
6.2.2. Procedure
1. Gain setup mode
1) User can set up Gain within a certain range.
① Down Link : 70B ~ 100B
② Up Link : 70dB ~ 100dB
2) Gain should be set up according to ICS repeater input condition.
(ex) When input is -40dBm, Gain can be over Max. 67 dB because ICS repeater
output cannot be over 37dBm)
3) When the Gain is less compared to Isolation, ICM set Attenuator. to optimized
value in order to protect the system, and CPU occurs alarm and displays
“Isolation deficient”
Æ When Isolation is back to normal, Gain return to the previous set-up and
“Isolation deficient” alarm is removed
2. OFF Mode
1) This can be established at the initial set-up or special occasion. When OFF mode,
Attenuator is set up to Maximum in order to protect the system
3. Gain Balance Mode
1) Up Link Gain is set up automatically as low as “Gain Balance set-up value
compared to Down Link current Gain
ICS-F0837 User manual/Confidential & Proprietary
RF Window Co., Ltd. |
34
ICS Repeater ICS-W0837B User Manual
2) Gain Balance set-up range is 0 ~ 10dB and this mode can be set up at the Up
Link
6.2.3. Others
At the initial execution, if Gain set-up is not executed normally, it is notified to the user and
holds the default Attenuator value
6.3. Total Power Limit
6.3.1. Objective
To give out Total Power to be less than the output power value which user wants and to
operate output power limit feature when output power is more than max. Output power setup
6.3.2. Procedure
1. Total Power Limit does not have additional operation Mode and it works based on
“max. output power value’ set up by user
1) Down Link Output Power set-up Range : ~ 38dBm/Total
2) Up Link Output Power set-up Range : ~ 28dBm/Total
2. Total Power Limit operating point: monitored value ≥ “max. output power set-up value
3. Total Power Limit Attenuator operating: After Down Link Attenuator change, turn down
Attenuator. To be 1 dB less than “max. output power set-up value”
1) The changed Attenuator. value should be stored in the system
2) When the changed Attenuator. value is reset
① RCU Reset
② Change User Attenuator. Value before changed Attenuator. value restored
4. Total Power Limit Restoration Point: Down Link Attenuator restoration condition is to
restore by 1 dB Step from 3 dB less than “max. output power set-up value”
5. Total Power Limit Restoration Attenuator operation: restore Attenuator. up to the value
of “max. output power set-up value: 2”
6. Restore preferentially the changed Attenuator. value
ICS-F0837 User manual/Confidential & Proprietary
RF Window Co., Ltd. |
35
ICS Repeater ICS-W0837B User Manual
7. Once Attenuator. is restored, this routine ends
6.4. Auto Recovery
6.4.1. Objective
To restore Dual HPA when the down link path of Dual HPA is shutdown (S/W based
Recovery feature).
6.4.2. Procedure
1. When Dual HPA is shutdown caused by over power until Down Link Path is in service
normally, CPU (in ICM) detects HPA shutdown and checks Down Link input level as
well as the gain right before the shutdown.
2. Dual HPA(in Down Link Path) Shutdown condition on Re-Check
1. When “Down Link Input Level” + “Gain right before Shutdown” ≥ System output
power + 1dBm
¾ “Over Power” Alarm on
9 Recovery Condition
2. When “Down Link Input Level” + “Gain right before Shutdown” ≤ System output
power
¾ Over Power Alarm off
6.5. Up Link Auto Shutdown Mode
6.5.1. Objective
To reduce unnecessary Up Link output power so that it minimizes influence to Base
Station
6.5.2. Procedure
1. It is operated by Auto Shutdown mode
2. If Down Link output power is OFF, then it turns off Up Link output power (except
turning off by user)
3. When Up Link output power is OFF, it executes Amp Off alarm and reports Reason
4. If Down Link output power is ON by Auto Recovery feature, then Up Link output
power is ON as well
ICS-F0837 User manual/Confidential & Proprietary
RF Window Co., Ltd. |
36
ICS Repeater ICS-W0837B User Manual
6.6. NMS Operation
6.6.1. Alarm Monitoring feature
1. Alarm occurs when alarm situation keeps on 10 sec continuously
2. Recovery is applied when alarm situation is not occurred for 10 sec continuously
3. Threshold Alarm : over and under each threshold is occurred and restored
6.6.2. LED Feature
1. POWER LED: Red LED is on when AC/DC Fail alarm occurred (Normal : Green)
2. DL ICM LED : Red LED is on when Down Link ICM alarm occurred (Normal : Green)
3. UL ICM LED : Green LED is on when Up Link ICM alarm occurred (Normal : Green)
4. RF LED : Red LED is on when RF module alarm occurred (Normal: Green)
5. Green LED is on when all is normal
ICS-F0837 User manual/Confidential & Proprietary
RF Window Co., Ltd. |
37
ICS Repeater ICS-W0837B User Manual
7. System Installation and Setup
7.1. Installation
7.1.1. Configuration
Item
Specification
Repeater Cabinet
ICS-F0837
AC & UPS Connector
MS3106A-20-18(9Pin Female)
Quick manual
User Manual
[Table - 11] System Configuration
AC & UPS Connector
MS3106A-20-18(9Pin Female)
Pin A : SERVICE_ALM_A
Pin B : AC_NUT
Pin C : LOW BATT_ALM_B
Pin D : ON BATT_ALM_A
Pin E : ON BATT_ALM_B
Pin F : GND
Pin G : LOW BATT_ALM_A
Pin H : SERVICE_ALM_B
Pin I : AC_HOT
[Table - 12] AC Connector Pin Assign
7.1.2. Installation
Locate repeater at necessary place and fix the bracket
Connector both antennas to Antenna Port
(DIN - Type Female Connector)
Ground repeater
Supply the Electrical Power (AC100~260V)
Verify if Main Power LED if the connection is correct (Extension code can be used if
necessary, not included)
Port Connection to Repeater is as follows
Item
Function
ICS-F0837 User manual/Confidential & Proprietary
RF Window Co., Ltd. |
38
ICS Repeater ICS-W0837B User Manual
AC IN
B : AC 100V~260V+
I : AC 110V~260V-
Modem Port
Tx/Rx
Donor Port
TX Input / RX Output
Service Port
TX Output / RX Input
F : GND
[Table - 13] System Connection Port
7.1.3. Check List before operation
Verify if all the connections are correct including Power Cable, RF Cables, Ground
and so on.
Verify if Power Box (100~260V) is connected correctly.
Verify if RF Cables have correct connection regarding block diagram.
Verify if each module power and data cable have correct connection
Verify if Connection with Antennas is correct.
7.1.4. RF Monitor Port
Donor Antenna
Service Antenna
TX(To BTS)
RX(from BTS)
TX(To Mobile)
RX(From Mobile)
15 dB Coupling
30 dB Coupling
40 dB Coupling
[Table - 14] RF Monitor Port
ICS-F0837 User manual/Confidential & Proprietary
RF Window Co., Ltd. |
39
ICS Repeater ICS-W0837B User Manual
7.3. Fault / Alarm Handling
7.3.1. Down Link / Up Link ALARM Handling
Module
Name
Alarm
High Input
Power
( DL / UL )
Alarm Status
Alarm : Red
Normal : Green
Symptom and Action
Verify Donor Antenna Input Level
Add Fix Attenuator,
Use LNA Attenuator (RF Window)
Verify Donor Antenna Cable,
Low Input
Power
RF
( DL )
Alarm : Red
Normal : Green
Power
RF Cables in Repeater,
Input level to ICS module
Replace cables, adjust ANT direction
High Output
Power
( DL / UL )
Low Output
Power
( DL )
Alarm : Red
Normal : Green
Alarm : Red
Normal : Green
ICS (DSP)
Alarm : Red
( DL / UL )
Normal : Green
Over Power
Alarm : Red
( DL )
Normal : Green
DL
High Temp.
Alarm : Red
PAU
( DL )
Normal : Green
VSWR
Alarm : Red
( DL )
Normal : Green
RF
RF Device
Alarm : Red
Device
( DL / UL )
Normal : Green
ICS
Antenna Direction,
Verify Gain and real output power using CPL
port
Adjust Gain
Verify Gain and real output power using CPL
port, Verify Each module In/Output
Adjust Gain, Replace the Module
Verify Isolation, Verify ICS Module defected.
Adjust ANT Direction and GAIN. Replace ICS
Module
Verify PAU Input Level, Output Level using
CPL Port
Adjust GAIN
Verify if PAU not fixed, Verify if dust on a Heat
Sink . Verify if PAU defected.
Fix PAU, Replace PAU
Verify Output cable status, Verify if antenna
defected. Verify if PAU defected
Replace the defected Part
Verify if the Module defected
Replace the Module
ICS-F0837 User manual/Confidential & Proprietary
RF Window Co., Ltd. |
41
ICS Repeater ICS-W0837B User Manual
UL
PAU
Alarm : Red
PAU
( UL )
Normal : Green
Verify if PAU defected.
Cable Connection Status
Replace the Module
[Table - 15] Down Link / Up link Alarm Handling
7.3.2. Environment Alarm
Item
Alarm Status
Door Open
Alarm : Red
Alarm
Normal : Green
AC Alarm
DC Alarm
Housing
Temp
Alarm
Alarm : Red
Normal : Green
Alarm : Red
Normal : Green
Alarm : Red
Symptoms and Actions
DOOR
Status,
DOOR
SW
Remark
operation
Check
DOOR Lock and Updating SW
Verify AC Voltage
Re-construct AC Power
Verify if PSU output is 27V
Replace PSU
Verify Housing Temp.
Normal : Green
[Table - 16] Environment Alarm
ICS-F0837 User manual/Confidential & Proprietary
RF Window Co., Ltd. |
42
ICS Repeater ICS-W0837B User Manual
8. Manufacturer Information
RF Window co. ltd.
Maker : RF Window Co., Ltd
Address: 14F, Daerung Posttower3, 182-4, Guro-3dong, Gurogu, Seoul, 152-847, South Korea
TEL: +82 –2- 2082-1250
ICS-F0837 User manual/Confidential & Proprietary
RF Window Co., Ltd. |
43

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : Yes
XMP Toolkit                     : 3.1-701
Producer                        : Acrobat Distiller 7.0 (Windows)
Creator Tool                    : PScript5.dll Version 5.2.2
Modify Date                     : 2010:02:04 17:59:19+09:00
Create Date                     : 2010:02:04 17:53:26+09:00
Metadata Date                   : 2010:02:04 17:59:19+09:00
Format                          : application/pdf
Title                           : Microsoft Word - User_Manual_ICS-F0837_v1.1.doc
Creator                         : Owner
Document ID                     : uuid:3ee6ef33-a2f0-476a-bc4e-531149780a5a
Instance ID                     : uuid:f7ff9c66-35f3-4e3f-a676-8bf5e53adcea
Has XFA                         : No
Page Count                      : 42
Author                          : Owner
EXIF Metadata provided by EXIF.tools
FCC ID Filing: X4O-ICS-F0837

Navigation menu