RFI Technology RFI-001 Wireless System for POS and Kitchen Printer User Manual FCC 2

RFI Technology Company Limited. Wireless System for POS and Kitchen Printer FCC 2

User Manual

Download: RFI Technology RFI-001 Wireless System for POS and Kitchen Printer User Manual FCC 2
Mirror Download [FCC.gov]RFI Technology RFI-001 Wireless System for POS and Kitchen Printer User Manual FCC 2
Document ID388964
Application IDl4rS4p7XQ/nm3ku13pXCsQ==
Document DescriptionUser Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize11.42kB (142739 bits)
Date Submitted2004-01-15 00:00:00
Date Available2004-01-09 00:00:00
Creation Date2003-12-06 12:27:01
Producing SoftwareAcrobat Distiller 5.0 (Windows)
Document Lastmod2003-12-06 12:27:01
Document TitleMicrosoft Word - User Manual FCC_2.doc
Document CreatorPScript5.dll Version 5.2
Document Author: Kenny Kam

SPRINTER Wireless System
User Manual
PWR/RT
KP1
KP4
KP3
KP 2
PW R/R
KP1
KP2
KP3
KP4
1.
General Description
ECR/POS MODULE (POS Module)
- It is connected to the ECR or POS.
- 4 × RJ45 sockets for connections to ECR or POS Serial Ports by
RJ45/DB9 cable.
- 1 × DC jack for power input
- 1 × Red LED for Power and RF Status.
- 4 × Green LEDs to indicate Data Port Status.
- 1 × Push Switch to enter Register Mode.
DC 5V
KP1
KP2
KP3
KP4
POS Module
LEARN
2.
Placement Orientation
SPRINTER can be placed on any flat surface or mounted on the
wall. In either case, the antenna must be set upward for better
reception of signal.
PWR/RT
KP1
KP 4
KP3
KP2
PW R/R
3.
KP1
KP2
KP3
KP4
Checklist for unpacking
Before start to install the SPRINTER system, please check the
items listed below:
POS Module Pack:
1 × POS Module
- 1 × Cable with RJ45/DB9 Connector
- 1 × AC/DC adaptor
If any thing missed, contact your dealer for supplement.
4.
Installation
Step 1 – Setup the Serial Port on your ECR/POS and Printer
The Serial port of the ECR/POS and Printer must be set as below:
- Baud Rate: 9600 bps
- Date length: 8 Bit
- Parity: None
- Stop Bit: 1 or more
- Handshaking: Hardware control (DTR/DSR)
Step 2 - Connecting the Modules
POS Module
It is simply connecting the POS module to ECR or POS serial port by
the RJ45/DB9 cable. If you have more than one Kitchen Printer, you
just need to purchase additional RJ45/DB9 cables from your dealer for
connecting the modules to ECR or POS. The Port Number on the POS
Module corresponds to the ID of the Kitchen Printer:
KP 1 Æ Kitchen Printer ID 1,
KP 2 Æ Kitchen Printer ID 2,
KP 3 Æ Kitchen Printer ID 3,
KP 1 KP 2 KP 3 KP 4
KP 4 Æ Kitchen Printer ID 4,
Step 3 – Connecting the Power
Before power up the SPRINTER system, all ECR, POS or
Kitchen Printers should be switched on in advance.
Plug the AC/DC adapter to the wall outlet. Then, connect the adapter
DC plug to the module’s DC input jack.
A self-test will be run automatically. The Power LED (Red) and the
Data LED (Green) will flash once. If no error found, the Power LED
will be stay on and other LEDs will be off. The system is ready to go!
If error is found, all LEDs will be flashing and long beep sound will
be heard. Unplug the power and plug in again. If still has error,
contact your dealer. If both the LED and buzzer back to normal
indications, continue the Register process in Step 6.
5.
LED & Buzzer Indications
Status
Power/RF
Data LED
Buzzer
Remark
LED
POS
Ready Mode
Steady ON
OFF
Silence
Transferring
Steady ON
Flashing
Silence
Module
No data in
processing.
Data
Printer error
Randomly
Stead ON
Stead ON
Printing in
progress.
Beep twice
Paper out, Printer
after time out. buffer full, or
Printer not ready.
RF Error
Flash for
Stead ON
Beep twice.
5 seconds
POS ID error
Flashing
RF error
during transmission.
Flashing
Continuous
Reset the power
Beep sounds
and redo the
Register procedure
again. If error still
exists, contact your
dealer.
6.
Cable connections
To ECR/POS Serial Port
DB 9
(Female) Pin
Description
I/O
Data Terminal
Ready (DTR)
Clear to Send
(CTS)
Data Set
Ready (DSR)
To SPRINTER POS Unit
DB9F
Pin #
RJ45
Pin #
I/O
RJ45 Pin
Description
Data Set
Ready
(DSR)
Request to
Send (RTS)
Data Terminal
Ready (DTR)
Signal GND
Signal GND
TxData
RxData
Request to
Send (RTS)
Rx Data
Tx Data
No Connection
No Connection
*All the information on this manual is subjected to change without
prior notice.
Caution
Modifications not authorized by the manufacturer may void users
authority to operate this device.
NOTE: This equipment has been tested and found to comply with
the limits for a class B digital device, pursuant to Part 15 of the
FCC Rules. These limits are designed to provide reasonable
protection against harmful interference in a residential
installation. This equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in accordance with
the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference
will not occur in a particular installation. If this equipment does
cause harmful interference to radio or television reception, which
can be determined by turning the equipment off and on, the user is
encouraged to try and to correct the interference by one or more
of the following measures:
-- Reorient or relocate the receiving antenna.
-- Increase the separation between the equipment and receiver.
-- Connect the equipment into an outlet on a circuit different from
that to which the receiver is connected.
-- Consult the dealer or an experienced radio/TV technician for
help.
*All the information on this manual is subject to change without prior
notice.

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.3
Linearized                      : No
Create Date                     : 2003:12:06 12:27:01+08:00
Modify Date                     : 2003:12:06 12:27:01+08:00
Page Count                      : 7
Creation Date                   : 2003:12:06 04:27:01Z
Mod Date                        : 2003:12:06 04:27:01Z
Producer                        : Acrobat Distiller 5.0 (Windows)
Author                          : Kenny Kam
Metadata Date                   : 2003:12:06 04:27:01Z
Creator                         : Kenny Kam
Title                           : Microsoft Word - User Manual FCC_2.doc
EXIF Metadata provided by EXIF.tools
FCC ID Filing: RPHRFI-001

Navigation menu