RSI VIDEOTECHNOLOGIES CM00 Keypad User Manual Installation Sheet

RSI VIDEOTECHNOLOGIES Keypad Installation Sheet

Installation Sheet

Product SummaryThe Keypad CMA601 is designed for use in configuration/programming and operating with a RSI Video Technologies security system. The keypad includes the following features:> Lithium batteries for long life.> 2-line, 16-character alphanumeric LCD display    with backlighting.> Armed status red LED.> Built-in piezo for status and alarm sounds.> Dual tamper function provides detection for both wall    and cover tamper.> Transmits check-in/status signal every 8 minutes.Installation GuidelinesFor easier installation, programming and RF testing  should be done to check for good communication between the control panel and all system devices before mounting system devices. Install the keypad and other devices in the order of the following steps:>  Programming/RF Testing - program keypad and    all other devices into the control panel and test    RF communication from each intended device    location to the control panel.>  Mounting - mount keypad at the tested location.Programming/RF TestingThe following provides summarized steps for device  programming and testing. For complete details, refer to the control panel installation manual.1  Remove bottom screw,    separate base from keypad    and install batteries.2  Re-attach base to    secure tamper switch.3  Put control panel    into programming/   configuration mode.4  On keypad, press and   hold Clr and Esc/No    buttons together for    one second, then release    them. Wait for keypad    display to show KEYPAD    1 RECORDED.5 Press Yes. The display    shows RADIO RANGE    TEST? Press Yes again.    The detector LED starts    flashing and keypad display    shows RF TEST #/96 Press Yes to end radio range test, then press Esc/No.Note: If this is the first keypad programmed in a new installation,  the  keypad display prompts you to enter other system configuration data. If you are adding the keypad to an existing (operational) system, proceed to step 9.8  Repeat steps 1 - 8 for all alphanumeric keypads.9  When finished, exit configuration mode.Note: The control panel assigns alphanumeric keypads automatically  to Zone 1 (Entry/Exit Delay).10   Refer to the users manual of your alarm panel to know how    use this device.www.videofied.comScrewCLR and ESC/NO ButtonsLEDPRODUCT INSTALLATION SHEETKeypad CMA601Made by RSI VIDEO TECHNOLOGIES 2222-CMAIS March 2012
Mounting> Use proper tools and hardware.> Mount indoors in a temperature-controlled environment.> Mount in a location that provides customer convenience,   but out of view from windows.1  Separate base from keypad.2  Hold base against mounting surface and mark the three      mounting holes. 3  Drill pilot holes and install   anchors where needed.4  Place base on mounting surface    so mounting holes line up with pilot           holes/anchors and secure base with    appropriate screws.5  Install batteries into keypad, observing                                    correct polarity.6  Attach keypad to base and secure with screws.Electrical DataPanel Compatibility  Videofied Alarm Panel XL,XT,XTIP, V6000Power requirements:        Type:   3.6v SAFT Lithium, LS14500, AA Batteries Only         Nominal Voltage:   3.6v         Low Voltage Limit:   3v         Quantity  3xBattery life (estimated)  Up to 4 years RF technology:  2 way S2View© RSI Technologies 915MHz frequency hoppingRadio type  Spread Spectrum Bidirectional RFOperating frequency  915 MHzTransmission security  AES algorithm encryptionSupervision  Panel polls devices every 8 minutesAntenna  IntegratedTamper detection  Wall and cover tamperedKeypad:         Keys:   23x Keys        Allowed Time for Code Entry:   60s        Number of Illegal codes:   186  (depending on panel features)        User code input attempts before lockout:  5        Lockout duration:  90 seconds        Memory Lifetime:  No Limit  (Flash Memory)Physical DataMaterial  ABS UL94-V0Dimensions   (LxWxD):6.3 x 3.6 x 1.2 Inches   (160 x 92 x 31 mm)Weight  6.35oz (180gr) without batteriesInstallation/MountingWall Mount  3 Screws (including one for the tamper)Case Lock   1 screw on bottom Certification & ApprovalsUSA  FCC  Part 15C  UL 1023 (Applied For)Assistance Request  PoliceDisplay type  Liquid-crystal (LCD)Display size  Two lines, 16 characters eachDisplay backlighting  AutomaticBuilt-in sounder:         Piezo Buzzer:    Emits entry/exit delay beeps, alarmsPanic button  One (Must be programmed/Enabled)Operating temperature  14° - +104° F (-10° - +40° C)Maximum relative humidity  75%, non-condensingwww.videofied.comMountingHolesKeypad CMA601 PRODUCT INSTALLATION SHEET
EMEA SALES23, avenue du Général Leclerc92340 BOURG-LA-REINEFRANCEHotline: +33 (0)820 846 620Fax: +33 (0)1 82 69 80 10© 2011 RSI VIDEO TECHNOLOGIES. VIDEOFIED® is a Registered Trademark of RSI VIDEO TECHNOLOGIES.  S2View® is a registered trademark of RSI VIDEO TECHNOLOGIES.  Specications subject to change without notice.USA SALES4455 White Bear Parkway, Suite 700White Bear Lake, MN 55110USAHotline: +1 877 206 5800Fax: +1 651 762 4693 www.videofied.comFCC Regulatory Information for USA and CANADAFCC Part 15.21 Changes or modifications made to this equipment not expressly approved by RSI VideoTechnologies may void the FCC authorization to operate this equipment.FCC Part 15.105 Class B This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.  This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.  However, there is no guarantee that interference will not occur in a particular installation.  If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:•                      Reorient or relocate the receiving antenna.•                       Increase the separation between the equipment and receiver.•                       Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.•                      Consult the dealer or an experienced radio/TV technician for help.Radio frequency radiation exposure information according 2.1091 / 2.1093 / OET bulletin 65This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance of 20 cm between the radiator and your body.This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.This device complies with Part 15 of the FCC Rules and with RSS-210 of Industry Canada.Operation is subject to the following two conditions:(1)  This device may not cause harmful interference, and (2)                      This device must accept any interference received, including interference that may cause undesired operation.Keypad CMA601 PRODUCT INSTALLATION SHEET

Navigation menu