Product SummaryThe Door Contact Models CT601 is a wireless door/window contact designed for use with RSI VIDEO Technologies security systems. The contact includes the following features: > Lithium battery for long life.> External input for normally closed (NC) intrusion devices.> Dual tamper function provides detection for both wall    and cover tamper.> Transmits check-in/status signal every 8 minutes.Programming/RF TestingThe following provides summarized steps for device  programming and testing. For complete details, refer  to the control panel installation manual.1  Loosen bottom screw, separate base   from detector and install battery.2  Re-attach base to secure tamper switch.3  Put control panel into programming/         configuration mode.4  Using a programmed alphanumeric   keypad, proceed through menus    until the display shows ADD A   NEW DEVICE.5 Press Yes. The display shows    PRESS PROGRAM BUTTON OF DEVICE.6  Press and release program button on detector using a      paper clip end. The detector LED flashes. Wait for keypad      display to show DETECTOR (1 - 25) RECORDED.7 Press Yes. The display shows RADIO RANGE TEST?   Press Yes again. The detector LED starts flashing and      keypad display shows TEST IN PROGRESS.8  Take detector to its intended mounting location and    make sure LED flashes continuously, indicating good      communication with control panel.9 Press Yes to end radio range test, then press Esc/No.10   The display shows AREA    ASSIGNMENT AREA: 1. Press   either arrow button repeatedly    until desired AREA  number    appears, then press Yes.11   The display shows PROTECT AN    EXTERNAL ACCESS? Press Yes or       Esc/No, whichever is appropriate        for this device.12   The display shows NAME + LOCATION.    Enter appropriate device name/location (up to    16 characters), then press Yes. The display shows    the device number and name for your verification.13  Press Yes. The display shows FUNCTIONAL DEVICE      TEST? Press Yes again and verify detector operation.    For example, move magnet next to detector to make    LED go out, then move magnet away from detector    to make LED turn on indicating detection. 14  Press Yes to end detection verification.15   The display shows ENTERING A NEW DEVICE?    Repeat steps 1 - 14 for remaining detectors.16   When finished, exit from configuration mode.Installation GuidelinesFor easier installation, programming and RF testing should be done to check for good communication between the control panel and all system devices before mounting system devices. Install the detector and other system devices in the following order:>  Programming/RF Testing - program detector and    all other devices into the control panel and test  RF    communication from each intended device location    to the control panel.>  Mounting - mount detector at the tested location.Remark: Only recorded contacts protecting the external access will be concerned by the Perimeter arming.                  Use the keypad to activate Perimeter only arming.  Press on          (to activate the keypad), then              shows on the                                               keypad enter a user code and validate with the key           . ScrewProgram ButtonLEDPRODUCT INSTALLATION SHEETDoor/Window Contact CT6012209-CTIS March 2012Made by RSI VIDEO TECHNOLOGIES
Mounting>  Use proper tools and hardware.>  Mount indoors in a temperature-controlled environment.>  Mount detector on frame and magnet assembly on movable    opening (door, window). >  When using internal switch, mount so that detector and    magnet alignment marks are lined up with each other.>  When using internal switch, do not exceed 10 mm (3/8”)   gap between detector and magnet.>  Magnet spacers must be used to match magnet height with     detector to ensure correct alignment and functionality.Note: If detector installation only requires use of the external input, magnet assembly installation is not required.1  Separate base from detector.2  Hold detector base against    mounting surface and mark    the two mounting holes.3  Drill pilot holes into mounting           surface.4  Mount detector base to surface          using appropriate screws.5  If using external input, run    2-conductor, 22-gauge wire from    protection point to detector.6  Connect hardwire circuit wires to    external input screw terminals.7  Connect other end of wires to   initiating device and install the                                                              battery.8  Attach detector to base, making        sure every wire is secure with screws.9  Attach wedges to magnet holder        as needed to match height of detector.10   Hold magnet base against    mounting surface and mark    the two mounting holes.Note: Be sure alignment marks on detector  and magnet base are lined up with each other  and that there is no more than a 10 mm (3/8”)   gap between them. 11   Drill pilot holes into mounting surface.12   Insert screws through magnet base and wedges,    then secure to mounting surface.13   Attach cover to magnet holder.External Input Terminal, Jumper position and wiringNote: The internal jumper wire is only used for internal or external switch use. The jumper is not used when both Int. and Ext switches are used together. The default jumper position is in the Internal switch mode. it only has to be changed if wiring external switches to the transmitter.The internal jumper shown in                   position for possible connections.1. Internal reed switch only2. External reed switch only3. Both Int. and Ext. switch use >  For the magnet to have proper detection, it must be positioned on the high part of the contact facing the ILS, use the supplied    wedges if needed. (see the diagram opposite).  >  Magnet should always be positioned on the mobile part. Three axis movement detectionInternal Reed SwitchExternal Reed SwitchInt + Ext Reed SwitchExternal Input TerminalsToInitiatingDeviceMounting HolesBaseWedge   IndicatorThe markers must be lined upMagnet + wedgesPROGRAM Button1 cm max.PRODUCT INSTALLATION SHEETDoor Contact CT601
Electrical DataPanel Compatibility  Visio, XT, XL, XTIPPower requirements       Type  C       Nominal Voltage  3.6V      Low battery limit  2.7V       QTY and Battery Type  One 3.6V Lithium batteryBattery type  SAFT Lithium, LS14500Battery life   Up to 4 yearsCurrent Consumption       Standby  30 uA      Max  70mAAxis of detection  Three axis (X, Y, Z)Opening Detection Distance  .9in (2.3cm)Closing Detection Distance  .8in (2.0cm)RF technology  S2View®Radio type  Spread Spectrum Bidirectional RFOperating frequency  915 MHzTransmission security  AES algorithm encryptionSupervision  Polled signal every 8 minutesAntenna IntegratedTamper detection  Wall and cover tamperedExternal terminal input type   Normally closed (NC)Working modes   1-internal reed switch only  2-external input only  3-internal switch and external inputMode selection  Jumper wire on 3-position terminal blockMaximum external wire length   16 m/50 feetOperating temperature   -10°/+40°C (14°/104°F)Maximum relative humidity  75%, non-condensingApprovals   FCC Part 15C  Physical DataMaterial  Plastic: ABS—ULV0Magnet  Alnico 5Dimensions    80  mm  x  35  mm  x  23  mm                                                                                                                                                                              (LxWxD): Detector: 3 1/8 in. x 1 3/8 in. x 1 in.Weight: Detector  40 g/1.4 oz. –without batteryInstallation/MountingDetector  One screw secures detector to base;    two screws secure detector to mounting surface.Magnet  Two screws secure magnet    assembly to mounting surface.Spacing  Maximum 10mm (3/8) in gap    between detector and magnet.INSTALLATION DATA SHEETDoor Contact CT601
PRODUCT INSTALLATION SHEETDoor Contact Models CT601EMEA SALES23, avenue du Général Leclerc92340 BOURG-LA-REINEFRANCEHotline: +33 (0)820 846 620Fax: +33 (0)1 82 69 80 10© 2011 RSI VIDEO TECHNOLOGIES. VIDEOFIED® is a Registered Trademark of RSI VIDEO TECHNOLOGIES.  S2View® is a registered trademark of RSI VIDEO TECHNOLOGIES.  Specications subject to change without notice.USA SALES4455 White Bear Parkway, Suite 700White Bear Lake, MN 55110USAHotline: +1 877 206 5800Fax: +1 651 762 4693 FCC Regulatory Information for USA and CANADAFCC Part 15.21 Changes or modifications made to this equipment not expressly approved by RSI VideoTechnologies may void the FCC authorization to operate this equipment.FCC Part 15.105 Class B This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.  This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.  However, there is no guarantee that interference will not occur in a particular installation.  If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:•                      Reorient or relocate the receiving antenna.•                       Increase the separation between the equipment and receiver.•                       Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.•                      Consult the dealer or an experienced radio/TV technician for help.Radio frequency radiation exposure information according 2.1091 / 2.1093 / OET bulletin 65This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance of 20 cm between the radiator and your body.This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.This device complies with Part 15 of the FCC Rules and with RSS-210 of Industry Canada.Operation is subject to the following two conditions:(1)  This device may not cause harmful interference, and (2)                      This device must accept any interference received, including interference that may cause undesired operation.

Navigation menu