RSI VIDEOTECHNOLOGIES DC00 Door/Window contact User Manual

RSI VIDEOTECHNOLOGIES Door/Window contact

Contents

user manual

Doc. - Ref. 219-IDCVersion : April 2014Installation GuidelinesFor easier installation, programming and RF testing should be done to check for good communication between the control panel and all system devices before mounting system devices. Install the detector and other system devices in the following order:> Programming/RF Testing - program detector and all other devices into the control panel and test  RFcommunication from each intended device location to the control panel.> Mounting - Mount detector at the tested location.Mounting Rules> Use proper tools and hardware.> Mount indoors in a temperature controlled environment.>  Mount detector on frame and magnet assembly on movable opening (door, window).> Do not exceed 20 mm (6/8”) gap between detector and magnet.> Magnet spacer must be used to match magnet height with detector to ensure correct alignment and functionality.> Do not install product on ferromagnetic surfaces.The Indoor Door Contact IDC 200/601/701 is a wireless door/window contact designed for use with Videofied security systems. The contact includes the following features:> Uses 1 Duracell CR123A Lithium battery for long life.> Dual tamper function provides detection for both wall and cover tamper.> Transmits check-in/status signal every 8 minutes.Product SummaryDoor Mounting HolesWall Mounting HolesMagnet BasePRODUCT INSTALLATION SHEETIndoor Door Contact  IDC200/601/702 (white) / IDC 210 (brown)www.videofied.com
Programming/RF Testing/MountingThe following provides summarized steps for device  programming, testing and mounting. For complete details, refer to the control panel installation manual.1 Loosen bottom screw and separate base from detector.2  Install 1 Duracell CR123 3v Lithium battery, observing correct polarity.   *Check that the LED flashes before staying RED3 Put control panel into programming/configuration mode.4  Using a programmed alphanumeric keypad, proceed through menus until the display shows ADD A NEW DEVICE.5 Press YES/OK. The display shows PRESS PROGRAM BUTTON OF DEVICE.6  Press and release program button on detector. The detector LED flashes. Wait for keypad display to show DETECTOR (1 - 25) RECORDED.7  Press YES/OK. The display shows RADIO RANGE TEST?    Press YES/OK again. The detector LED starts flashing and keypad display shows TEST IN PROGRESS.8 Take detector to its intended mounting location and make sure LED flashes continuously, indicating good communication with control panel.9 Press YES/OK to end radio range test, then press Esc/ No.10  The display shows AREA ASSIGNMENT AREA: 1. Press either arrow button repeatedly until desired AREA number appears, then press YES/OK.11 The display shows PERIMETER DEVICE?       Press YES/OK or Esc/No, whichever is appropriate for this device.12 The display shows NAME + LOCATION:Enter appropriate device name/location (up to 16 characters), then press YES/OK. The display shows the device number and name for your verification.13 Press YES/OK. The display shows FUNCTIONAL DEVICETEST? Press YES/OK again and verify detector operation. For example, move magnet next to detector to make LED go out, then move magnet away from detector to make LED turn on indicating detection. 14 Press YES/OK to end detection verification.15 The display shows ENTERING A NEW DEVICE? Repeat steps 1 - 14 for remaining detectors.16 When finished, exit from configuration mode.Note: Only contacts protecting the external access should be configured for Perimeter arming.Programming             Buttonwww.videofied.comPRODUCT INSTALLATION SHEET2Indoor Door Contact  IDC200/601/702 (white) / IDC 210 (brown)
(EN) Security notes / (FR) Notes de sécurité / (DE) Hinweise zur SicherheitEnglish Francais Deutsch> Remove batteries before any maintenance!> WARNING, there is a risk of explosion if a        battery is replaced by an incorrect type!>  Observe polarity when setting up the batteries!> Do not throw used batteries!  Bring them to your installer or a collection point.> Attention ! Il y a un risque d’explosion si l’une des piles utilisées est remplacée par une pile de type incorrect !> Respectez la polarité lors de la mise en place des piles !>   Ne jetez pas les piles usagées ! Ramenez-les à votre installateur ou à un point de collecte spécialisé. > Batterien vor jeglichen Wartungsarbeiten entfernen!>   Vorsicht, es besteht Explosionsgefahr, wenn eine Batterie durch eine Batterie falschen Typs ersetzt wird!> Achten Sie beim Einsetzen der Batterien auf die Polung! >  Entsorgen Sie Batterien nicht im normalen Haushaltsmüll! Bringen Sie Ihre verbrauchten Batterien zu den öffentlichen Sammelstellen.FCC Regulatory Information for USA and CANADAFCC Part 15.21 Changes or modifications made to this equipment not expressly approved by RSI VideoTechnologies may void the FCC authorization to operate this equipment.FCC Part 15.105 Class BThis equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:> Reorient or relocate the receiving antenna.>  Increase the separation between the equipment and receiver.>  Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.> Consult the dealer or an experienced radio/TV technician for help.Radio frequency radiation exposure information according 2.1091 / 2.1093 / OET bulletin 65This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance of 20 cm between the radiator and your body.This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.Cet équipement est conforme aux limites d’exposition aux rayonnements IC établies pour un environnement non contrôlé.Cet équipement doit être installé et utilisé avec un minimum de 20 cm de distance entre la source de rayonnement et votre corps.This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.This device complies with Part 15 of the FCC Rules and with RSS-210 of Industry Canada.Operation is subject to the following two conditions:1 This device may not cause harmful interference, and 2 This device must accept any interference received, including interference that may cause undesired operation.Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio exempts de licence.L’exploitation est autorisée aux deux conditions suivantes:1 L’appareil ne doit pas produire de brouillage, et2 L’utilisateur de l’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d’en compromettre le fonctionnement. www.videofied.comPRODUCT INSTALLATION SHEET3Indoor Door Contact  IDC200/601/702 (white) / IDC 210 (brown)
PropertiesPanel Compatibility  XL, XLL, Visio, XT, XV and their variantsPower Requirements Nominal Voltage  3.0VLow battery limit  2.7VBattery Type  LithiumQuantity 1Manufacturer and reference  Duracell, CR123ABattery life   Up to 4 yearsCurrent Consumption Standby  35 µAMax  35 mAMagnet DetectionDetection axis (X1, X2, Y, Z)   Opening detection distance  20 / 20 / 29 / 41 (mm)  Closing detection distance  4 / 6 / 16 / 24 (mm)Initialization delay  10sRecovery delay  2sRF Technology S2View®Radio type  Spread Spectrum Bidirectional RFCentral Frequency :  868MHz  :  IDC200 & (Europe, Africa, Asia)  915 MHz FHSS  :  IDC601 (USA, Canada, South America)  920MHz FHSS  :  IDC701 (Australia, South America)Transmission Security  AES algorithm encryptionSupervision  Polled signal every 8 minutesAntenna IntegratedTamper  Wall and cover tamperInstallation / MountingDetector   One screw secures cover to base;    Two screws secure detector to mounting surface.Magnet     Two screws secure magnet assembly to mounting surface.StandardsNF EN50131-2-6:  2008 Grade 2 RTC 50131-2-6:  2011NF EN50131-5-3:  2005 NF EN50130-4:   2011NF EN50130-5:   2011 Classe II Certifying agency :CNPP Cert. Route de La Chapelle Réanville CS22265F—27950 SAINT MARCELTel : +33(0)2.32.53.63.63Fax: +33(0)2.32.53.64.46Sites Internet : http://www.cnpp.comEmail : certification@cnpp.comCertifying agency :AFNOR Certification11, rue François de Pressensé93571 Saint Denis La Plaine CedexTel : +33(0)1.41.62.80.00Fax: +33(0)1.49.17.90.00Sites Internet : http://www.afnor.org et http://www.marque-nf.comEmail : certification@afnor.org Certifications  CE / EN50131 / NF&A2P Standards EN60950-1:2006+/A11:2009+/A1:2010EN300220-1 V2.4.1EN300220-2 V2.4.1NF&A2P – 2 boucliers – suivant le référentiel NF324-H58Matériels de sécurité électroniques, détection d’intrusionDETECTEUR D’OUVERTURE A CONTACTCommercial Brand :  VideofiedProduct reference :   IDC200 (blanc)  IDC210 (brun)Certification Number :  2123200004A0  2123200004B0Others Certifications Netherlands  NCP  Singapour  IDA   South Africa  ICASA 915MHz FHSS - IDC601Certifications   USA  FCC Part 15C (FCC47 CFR Part 15)   Canada  IC (RSS-210 Issue 8)920MHz FFHS - IDC702 Certifications  Australie  C-Tick (AS-NZS4268)© 2013 RSI Video Technologies Videofied® and MotionViewer®  are  Registered Trademark of RSI Video Technologies. Specifications subject to change without notice.Physical DataOperating temperature   -10° to +55°C (14° to 131°F)Maximum relative humidity  75%, non-condensingMaterial  Plastic: ABS—ULV0Magnet  Alnico 5Dimensions LxWxDBody  3.7 x 1 x 0.86in (95 x 25.8 x 22mm)Spacer  2.5 x 0.59 x 0.39in (64 x 15 x 10mm)Magnet  2.5 x 0.59 x 0.43in (64 x 15 x 11mm)Weight: Detector  38g/1.4oz. – without batteryPhysical Protection  IP31 and IK04Standards & Certifications868MHz - IDC200 & IDC210North American Headquarters1375 Willow Lake Blvd, Suite 103Vadnais Heights, MN 55110USAE-Mail : usasales@rsivideotech.comEMEA SALES23, avenue du Général Leclerc92340 BOURG-LA-REINEFRANCEE-Mail : emeasales@rsivideotech.comwww.videofied.com 4PRODUCT INSTALLATION SHEETIndoor Door Contact  IDC200/601/702 (white) / IDC 210 (brown)

Navigation menu