RSI VIDEOTECHNOLOGIES SV50 Outdoor Streaming Motion Viewer User Manual Manual OSMVC601

RSI VIDEOTECHNOLOGIES Outdoor Streaming Motion Viewer Manual OSMVC601

Contents

Manual_OSMVC601

Download: RSI VIDEOTECHNOLOGIES SV50 Outdoor Streaming Motion Viewer User Manual Manual OSMVC601
Mirror Download [FCC.gov]RSI VIDEOTECHNOLOGIES SV50 Outdoor Streaming Motion Viewer User Manual Manual OSMVC601
Document ID3314718
Application IDgsn40+K+t2HRJpva5BKEVQ==
Document DescriptionManual_OSMVC601
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize138.53kB (1731681 bits)
Date Submitted2017-03-13 00:00:00
Date Available2017-03-13 00:00:00
Creation Date2016-08-19 12:23:57
Producing SoftwareAdobe PDF Library 15.0
Document Lastmod2016-08-19 12:24:10
Document TitleManual_OSMVC601
Document CreatorAdobe InDesign CC 2015 (Windows)

OSMVC OUTDOOR STREAMING MOTION VIEWER
INSTALL SHEET
DOC. - REF. 213-OSMVC
VERSION : AUGUST 2016
Product Summary
The OSMVC 200/601/702 MotionViewer is a wireless, battery
operated, motion activated outdoor camera designed for use in
Videofied ® security systems.
• Powered by 4 Lithium batteries for extended battery life.
• Lens for vertical curtain detection.
• 4 infrared LEDs for 12m night vision.
• Fully
weatherproof
(IP54)
and
temperature
resistant
(-25°C/+70°C).
• Tilt sensor tamper.
• Transmits check-in/status signal every 8 minutes.
• Video capture and transmission in «streaming mode» on user
request.
Installation Guidelines
For easier installation, programming and RF testing should be done to check
for good communication between the control panel and all system devices
before mounting system devices.
Install the detector and other system devices in the order of the following
steps:
> Programming/RF Testing - program detector and all other devices into the
control panel and test RF communication from each intended device location
to the control panel.
> Mounting - mount detector at the tested location.
Mounting
> Use proper tools and hardware.
> Mount camera between 2.5 m to 3,5 m height.
> The OSMVC MotionViewer detection distance may vary depending the
detector mounting (height, tilt). The OSMVC is not suitable to protect an area,
it needs to be used to protect the perimeter of an installation.
> Mount detector aimed to protect the perimeter.
> In order to reduce false alarms, do not aim the detector toward vegetation,
a road, or unlimited space.
MB110 Mounting kit for
Outdoor MotionViewer
> Do not cover the Fresnel lens.
INSTALL SHEET
OSMVC OUTDOOR STREAMING MOTION VIEWER
Programming/RF Testing/Mounting
The following provides summarized steps for device
programming, testing, and mounting. For complete details,
refer to the control panel installation manual.
Separate the base from the box
Install 4 3.6V LS14500 SAFT
batteries observing correct polarity.
10
The keypad displays :
AREA : 1
Screw
Press either arrow button repeatedly until desired area number
appear then press OK/YES. By default all devices in Area 1 are
automatically delayed.
11
Press OK/YES. the display shows PRESS PROGRAM
BUTTON OF DEVICE.
Press and release program button
on the OMV MotionViewer.
The display shows NAME + LOCATION:
Enter appropriate device name/location (up to 16 characters),
then press OK/YES. The display shows the device number and
name for your verification.
12 Mount the OSMVC on the MB 110 or the MBW110 Mounting
kit. Follow the installation guidelines shown in this document.
The OMV PIR flashes.
Wait for keypad display to show
CAMERA(1 - 25) PROGRAMMED. Press
OK/YES, the display shows RADIO
RANGE TEST? Press OK/YES again. The
camera LED starts flashing and keypad
display shows RF TEST.
Press OK/YES to end radio range test then press ESC/NO.
AREA ALLOCATION :
Put
control
panel
into
Programming/Configuration mode.
Using
programmed
alphanumeric keypad, proceed
through menus until the display
shows ADD A NEW DEVICE.
13 Press OK/YES. The display shows FUNCTIONAL DEVICE
TEST? Press OK/YES and verify camera operation. The
activation of the LED will determine the detection field.
Program button
Take the OSMVC camera to its intended mounting location
and make sure LED flashes continuously or you receive a 9/9
indicating good communication with the control panel.
14
Press OK/YES to end detection verification.
15 The display shows OPERATION COMPLETED or ADD A
NEW DEVICE? Press YES/OK. Repeat steps 1 – 14 for remaining
cameras.
16
When finished, exit from configuration mode.
INSTALL SHEET
OSMVC OUTDOOR STREAMING MOTION VIEWER
Mounting Recommendations
Please direct the OSMVC along a fence or a wall in order to protect an access point. The detector should not
be mounted close or above an access point. Such installation increase the probability of a missed intrusion.
For optimal use, the OSMVC MotionViewer mounting shall respect the following recommendations:
Mounting height :
RSI Video Technologies recommends a 2,5 m to 3,5 m mounting height.
When you install the MotionViewer higher, the detection distance is raised. However the sensitivity is reduced
and the blind area under the MotionViewer is larger.
When you install the MotionViewer lower, the sensitivity is raised and the blind area under the detector is reduced.
However the detection distance will be reduced.
Tilt :
Raising or reducing the tilt, even slightly, has a big impact on the detection distance and on the blind area under the
MotionViewer. We recommend to slightly tilt the OSMVC to reduce its detection range and avoid false alarms.
To precisely determine the tilt angle use a smartphone app like Smart Protector (Android) or Pitch Gauge (iOs).
Max detection distance :
OSMVC
Mounting height
Tilt angle
5°
10°
15°
20°
30°
2.5 m
14 m*
11 m
8m
6,5 m
2.75 m
14 m*
12 m
9m
7m
5m
3m
14 m*
13 m
9,5 m
7,5 m
5,5 m
3.25 m
14 m
10 m
8m
5,5 m
3.5 m
14 m*
11 m
8,5 m
6m
Theoretical values estimated for default sensitivity.
These values only represent the physical limits of the OSMVC detection and not its maximum detection range. Long range sensitivity
is reduced and depends on infrared detection properties (see page 5).
* In some cases, false alarms can be triggered from outside the 14m detection limit (street, bushes, trees, etc). If that happens, please
slightly tilt the OSMVC downward to prevent false alarms.
Tilt
Mounting
height
Blind angle
Max detection distance
INSTALL SHEET
OSMVC OUTDOOR STREAMING MOTION VIEWER
Perimeter protection
Streaming option
The new OSMVC MotionViewer allow the user to request a live video session.
The OSMVC is the first battery-powered wireless camera detector emitting on 868MHz able to provide a live video
stream from its camera.
The 868 MHz frequency has excellent range and allow for excellent battery-life.
Tilt Tamper
The OSMVC MotionViewer can detect
manipulation thanks to its built-in electronic
accelerometer.
This device can detect shocks, movements,
wall or cover tamper but also changes in its
orientation.
Transverse axis rotation
Longitudinal axis rotation
When a movement of the OSMVC is detected,
the LED lights up for 3 seconds.
When it is armed for the first time, the OSMVC registers its position in space. If its orientation is
significantly changed on its transverse or longitudinal axis, a tamper alarm is sent to the panel. As for every
Videofied device, the tamper is active 24/7.
If the detector is moved, the TAMPER notification will be displayed on the keypad the next time the
system is armed. Press OK/YES to acknowledge that notification and confirm the detector new
position. If the TAMPER event is set as ALARM/END, a tamper restoral event is sent to the panel.
Tilt tamper disabling (only for OSMVC version 07.06.04.XX and later)
The OSMVC Motionviewer must be deleted from the panel memory to disable tamper.
1.
Delete the OSMVC from the device configuration menu.
2.
Press and hold the OSMVC initialization button for 5 seconds. The red LED will turn on for 2 seconds to confirm the
setting.
3.
Pair the OSMVC back with your panel.
The re-enabling tamper procedure is the same as described above. When the tamper is enabled however, the red LED
turns on for 2 seconds, turns off for half a second and turns back on for 2 seconds.
OSMVC OUTDOOR STREAMING MOTION VIEWER
INSTALL SHEET
Infrared detection
The OSMVC outdoor MotionViewer uses standard infrared detection. The PIR is optimized for the detection of
individuals.
Several parameters affect the detection :
•
Subject thermal signature (size, width, temperature and emissivity).
•
Detection environment (ambient temperature, reflectivity of the surfaces, the presence of water or moist
surfaces).
•
Speed and direction of the movement.
•
OSMVC setup (tilt, height, sensitivity).
Detection beams
Individual thermal
signature at 3 m
Individual thermal
signature at 12 m
Vehicle thermal
signature at 12m
Blind angle
Important :
It is essential to monitor the proper functioning of the infrared detection using the FUNCTIONAL TEST feature in the
panel MAINTENANCE menu.
A red status LED lights up when the OSMVC is detecting. Use that test to determine the pattern of the detection
field.
12 m
4m
1m
Status LED
Detection curtain
(standard sensitivity)
INSTALL SHEET
OSMVC OUTDOOR STREAMING MOTION VIEWER
Sensitivity adjustment
The OSMVC detector comes with the capability of adjusting the sensitivity level of the PIR. It can improve the
detection or, on the contrary, reduce false alarms. Raising sensitivity will raise detection range, the detection
field will be larger and smaller thermal signatures will be detected. You should only use this feature when the
site has been diagnosed as needing this adjustment. It cannot be used to optimize detection as the adjustment
may be too high and generate either false alarms or missed intrusions.
Examples : Plant growth, pets.
Please note that the detector must be installed to prevent intrusions (aim the detector towards an access
point), sensitivity adjustment will have no effect if the installation doesn’t comply with the installation
recommendations described in this document.
Adjust sensitivity for the OSMVC MotionViewer
To change the OSMVC sensitivity, you need to change the detector name:
DEVICE
CONFIGURATION
To select the OSMVC
OK or YES
CHANGE NAME
DEVICE
OK or YES
Enter the detector name then enter the $ symbol at the end and the chosen digit
(without space). The number following $ will depend on the necessary adjustment:
SENSITIVITY
ADJUSTMENT
MINIMAL
SENSITIVITY
detector_name$2
LOW SENSITIVITY
detector_name$1
DEFAULT
SENSITIVITY
detector_name
HIGH SENSITIVITY detector_name$8
MAXIMAL
SENSITIVITY
detector_name$9
$ Symbol
CMA keypad : Press @ repeatedly until $ is displayed
XMA/XMB keypad : Press 1 repeatedly until $ is displayed
OSMVC OUTDOOR STREAMING MOTION VIEWER
INSTALL SHEET
Security notes / (FR) Notes de sécurité / (DE) Hinweise zur Sicherheit
English
Français
Deutsch
• Remove the batteries before any
maintenance !
• WARNING, there is a risk of explosion if a battery
is replaced by an improper model !
• Observe polarity when setting up the batteries!
• Do not litter the batteries when they are used!
Dispose of them properly according to Lithium
Metal requirements
• Retirez les piles avant toute opération de
maintenance !
• Attention ! Il y a un risque d'explosion si la batterie
utilisée est remplacée par un mauvais modèle !
• Respectez la polarité lors de la mise en place des
piles !
• Ne jetez pas les batteries usagées !
Ramenez-les à votre installateur ou à un point de
collecte spécialisé.
• Batterien vor jeglichen Wartungsarbeiten
entfernen!
• Vorsicht, es besteht Explosionsgefahr, wenn eine
Batterie durch eine Batterie falschen Models
ersetzt wird!
• Achten Sie beim Einsetzen der Batterien auf die
Polung!
• Entsorgen Sie Batterien nicht im normalen
Haushaltsmüll! Bringen Sie Ihre verbrauchten
Batterien zu den öffentlichen Sammelstellen.
FCC Regulatory Information for USA and CANADA
FCC Part 15.21 Changes or modifications made to this equipment not expressly approved by RSI Video Technologies may void the FCC
authorization to operate this equipment.
FCC Part 15.105 Class B
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses
and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference
to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does
cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is
encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
Radio frequency radiation exposure information according 2.1091 / 2.1093 / OET bulletin 65
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed
and operated with minimum distance of 20 cm between the radiator and your body.
Cet équipement est conforme aux limites d’exposition aux rayonnements IC établies pour un environnement non contrôlé.
Cet équipement doit être installé et utilisé avec un minimum de 20 cm de distance entre la source de rayonnement et votre corps.
This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.
This device complies with Part 15 of the FCC Rules and with Industry Canada licence-exempt RSS standard(s)
Operation is subject to the following two conditions:
This device may not cause harmful interference, and
This device must accept any interference received, including interference that may cause undesired operation.
Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio exempts de licence.
L’exploitation est autorisée aux deux conditions suivantes :
L’appareil ne doit pas produire de brouillage, et
2 L’utilisateur de l’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d’en compromettre
le fonctionnement..
INSTALL SHEET
OSMVC OUTDOOR STREAMING MOTION VIEWER
ELECTRICAL PROPERTIES
DETECTION PROPERTIES
Panel compatibility
Infrared detection specifications
W panels
Streaming option
X and VISIO panels
Without streaming option
Power requirements
Type C - 4 Lithium batteries 3,6 V LS14500
Battery life
4 years
High usage (about 30 videos per month)
2 years
Max current consumption
130 μA
320 mA
RADIO PROPERTIES
Supervision
Radio antenna
Dual element sensor
Detection lens
Tilt
1 m wide curtain
Spread spectrum bidirectionnal
AES encryption algorithm
Radio, batteries, tamper, position
Integrated
VIDEO PROPERTIES
Position change, shock, wall and cover tamper
BOX
Physical properties
Material
Weight
Operating frequency
• 868MHz - OSMVC 200 (Europe, Africa, Asia)
• 915 MHz - OSMVC 601 (USA, Canada, South America)
• 920 MHz - OSMVC 702 (Australia, South America)
Transmission security
Type
Dimensions
RF S2View® technology
Radio type
Passive infrared DSP
Tamper detection
Standard usage (up to 5 videos per month)
Standby current consumption
Technology
Polycarbonate UL94
130,5mm x 102,44mm x 141,5mm
261g (without batteries)
Environmental data
Operating temperature
Max. relative humidity
Protection marking
-25°/+70°C
95%, without condensing
IP 65 / IK 06
Installation / Mounting
Mounting height
Mounting angle
Mounting
2.5 m to 3.5 m
5° to 10°
Use mounting kit (sold separately)
Camera
Angle
Sensor type
90°
CMOS
Lighted video
Programmable : Color or B&W
Night vision video
Black & white automatic infrared
Infrared illumination
Infrared illumination distance
Automatic with 4 IR LEDs
Up to 12m
Video
Video format
Framerate
Video resolution
Average video file size
H264 (MPEG if not available)
5 images per second
QVGA (320x240)
220 ko
Snapshot
Format
Resolution
Average snapshot file size
JPEG
VGA (640x480)
8 ko
INSTALL SHEET
OSMVC OUTDOOR STREAMING MOTION VIEWER
STANDARDS AND CERTIFICATIONS
868MHz (OSMVC 200)
915MHz (OSMVC 601)
Compliant with the annex IV of the R&TTE Directive 1999/5/EC
Part 15C
USA FCC
RSS-247 Issue 1
Canada IC
920MHz (OSMVC 702)
Australia C-Tick
AS/NZS4268
This symbol on the product or on its packaging indicates that this product should not be treated as household
waste. It must be handed over to the applicable collection point for the recycling of electrical and electronic
equipment. By ensuring this product is disposed of correctly, you will help prevent potential negative
consequences for the environment and human health. The recycling of materials will help to conserve natural
resources.
For more information about recycling of this product, please contact your local municipality, your waste
disposal service or the company that installed the product.
EMEA SALES
23, avenue du Général Leclerc
92340 BOURG-LA-REINE
FRANCE
E-Mail : emeasales@rsivideotech.com
www.videofied.com
North American Headquarters
1375 Willow Lake Blvd, Suite 103
Vadnais Heights, MN 55110
USA
E-Mail : usasales@rsivideotech.com
The EC declaration of conformity of
this product is available by flashing
that QR code :

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : Yes
Language                        : fr-FR
XMP Toolkit                     : Adobe XMP Core 5.6-c111 79.158366, 2015/09/25-01:12:00
Create Date                     : 2016:08:19 12:23:57+02:00
Metadata Date                   : 2016:08:19 12:24:10+02:00
Modify Date                     : 2016:08:19 12:24:10+02:00
Creator Tool                    : Adobe InDesign CC 2015 (Windows)
Instance ID                     : uuid:6ff62975-c5fc-4838-b10e-e4ca25543395
Original Document ID            : xmp.did:1a7ab4ca-f8fa-be43-a670-8943a9c232b1
Document ID                     : xmp.id:bd822d0f-082c-0549-9ed2-985359f6f9b7
Rendition Class                 : proof:pdf
Derived From Instance ID        : xmp.iid:3a3d5596-1bac-de48-b6fe-95dcab56605d
Derived From Document ID        : xmp.did:17128b55-805c-da48-9684-81a859853e4d
Derived From Original Document ID: xmp.did:1a7ab4ca-f8fa-be43-a670-8943a9c232b1
Derived From Rendition Class    : default
History Action                  : converted
History Parameters              : from application/x-indesign to application/pdf
History Software Agent          : Adobe InDesign CC 2015 (Windows)
History Changed                 : /
History When                    : 2016:08:19 12:23:58+02:00
Format                          : application/pdf
Producer                        : Adobe PDF Library 15.0
Trapped                         : False
Page Count                      : 9
Creator                         : Adobe InDesign CC 2015 (Windows)
EXIF Metadata provided by EXIF.tools
FCC ID Filing: X46SV50

Navigation menu