RSI VIDEOTECHNOLOGIES XT03 control panel User Manual Installation manual
RSI VIDEOTECHNOLOGIES control panel Installation manual
Installation manual
Document #2002-XTIPIN COMPLETE SETUP AND PROGRAMMING MANUAL FOR XT-IP 630 PANELS A Videofied CMA/XMB/XMA/WMB Alphanumeric Keypad or Frontel TMT2 is required for programming and maintenance WMB CMA XMB/XMA 1375 Willow Lake Blvd. #103 Vadnais Heights, MN 55110 877-206-5800 2013/01/18 Ed 1 Setup and Programming manual for XTIP series Table of Contents Page FCC Installation Guidelines Introduction Initial Programming 6-16 Device Installation 17 Disabling Monitoring 18 Entering Badges and Access Codes 19-20 Choosing Siren Options 20 Ethernet Parameters and Testing 21 Testing GPRS / 3G Level and Error Codes List 22 Testing Device RF Level 23 XTIP Power Chart 24 Arming Input Wiring Diagram 25 Testing to Central Station 26 Mounting XT/XTX 27 Programmable Input Configuration 28-30 Programmable Output Configuration 31-33 Configuring Scheduling 34-36 Troubleshooting 37-39 After Initial Programming Flow Chart 40-41 Addendum 42-43 1375 Willow Lake Blvd. #103 Vadnais Heights, MN 55110 2|Page 2013/01/18 Ed 1 Setup and Programming manual for XTIP series Regulatory Information for USA and Canada FCC Part 15.21 Changes or modifications made to this equipment not expressly approved by RSI Video Technologies may void the FCC authorization to operate this equipment. FCC Part 15.105 Class B This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. Radiofrequency radiation exposure information according 2.1091 / 2.1093 / OET bulletin 65 This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance of 20 cm between the radiator and your body. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. This device complies with Part 15 of the FCC Rules and with RSS-210 of Industry Canada. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Cet appareil est conforme à la Partie 15 des règlementations de la FCC et avec la norme RSS210 de l'Industrie Canadienne. Son fonctionnement est soumis aux deux conditions suivantes : (1) Cet appareil ne doit pas causer d'interférences nuisibles et (2) Cet appareil doit accepter toute interférence reçue, y compris les interférences pouvant entraîner un fonctionnement indésirable. 1375 Willow Lake Blvd. #103 Vadnais Heights, MN 55110 3|Page 2013/01/18 Ed 1 Setup and Programming manual for XTIP series Basic Setup Guidelines for Installation and Programming Pre-Setup 1) Obtain the account number from the Central Station. 2) If using Cellular communication for primary or backup, activate the SIM card through your cellular provider a. *Do these steps at least 1 day before the install. System Programming and Setup 1) Setup and program the system in the office or in your vehicle. DO NOT MOUNT THE DEVICES. (Pages 6-16) 2) Disable monitoring so that signals are not sent until you are ready to send them. (Page 18) 3) Add user codes and or badges after initial programming. (Pages 19-20) 4) Silence the siren before arming for testing (If siren is present). (Page 20) Deploying the System on Site 1) Place the panel where you want to mount it and run the Ethernet cable. In Maintenance run the ETH. STATUS test to make sure you are receiving an IP. If you are using cellular as backup or primary make sure you get 3/5 or better when running the 2G3G Level Test in maintenance. If not, you will need to move the panel and run the test again.* (Page 22) 2) Deploying Devices: Use your keypad to run the RF test for each device. If you get a 9/9 for your RF test on the first device, then mount it. If not, you will need to move the device to get optimal signal.* (Page 24) a. If you are not getting an appropriate 2G3G or RF level, you can add an external antenna for either signal. (Not available for the XL600) Enabling External Antenna: (Page 23) 3) Re-enable monitoring before you send signals (Page 20) a. If you are currently using TMT Installer to program the system you can now take still pictures from each MotionViewer using the software. See TMT Installer Users Manual available on http://support.videofied.com 4) Once you have everything mounted, arm the system and trip one MotionViewer at a time. Make sure you stand in front of each MotionViewer for 10 seconds so the central station has some video to look at. (Page 27) 5) After you have sent signals to central station, call to verify. The following pages will go through each one of these steps and, if you have any issues please consult the troubleshooting section Pages 39-41. If you still cannot resolve the issue, please feel free to call technical support through live support chat and ticket submission at support.videofied.com. Sleeping mode and Wake-up on the CMA: They keypad backlight will go out after 30 seconds of inactivity. When you press a button the keypad wakes up. The first touch on the pad that wakes it up will not be a registered command and will only wake up the keypad. Sleeping mode and wake-up on the XMA/XMB: The keypad backlight will go out after 30 seconds of inactivity. The first touch on the keypad will wake up the keypad and will register as a command to the control panel. 1375 Willow Lake Blvd. #103 Vadnais Heights, MN 55110 4|Page 2013/01/18 Ed 1 Setup and Programming manual for XTIP series Introduction: Description: The XTIP control panel is a Videofied wireless, battery operated hybrid alarm system. It is designed for residential, small business and commercial security applications. The XTIP provides integrated Video Verification and features dual communication paths: Ethernet and 2G3G (3G or less). The XTIP has programmable inputs and outputs. XTIP also features mapping where an external input can be used to generate a video clip from a MotionViewer. Internal RF range and GPRS / 3G range can be enhanced using external antennas. Supervised Wireless Technology: The XTIP, along with all Videofied devices, uses the patented S2View® - Spread Spectrum, Videofied, Interactive, AES Encrypted Wireless technology, providing optimum signal integrity and security. The bi-directional RF communication path between all devices and the system control panel guarantees high signal reliability. Integrated antennas eliminate protruding wires or rods, which are difficult to install, unsightly to consumers and potentially troublesome if damaged. The panel supervises every device (excluding the remote key fob) to validate current open/close state, tamper condition, serial number, date of manufacture, firmware revision, and battery status. In order for an installation to be UL compliant you must follow the specifications in the table below: Type Audio Audio Delays Specifications When a MotionViewer is installed on the system you may not have the siren sound for less than 60 seconds If no MotionViewer is installed on the system you may not have the siren sound for less than 240 seconds When a MotionViewer is installed on the system the Entry delay must be 45 seconds 1375 Willow Lake Blvd. #103 Vadnais Heights, MN 55110 Location In Manual Page 43 Page 43 Page 9 5|Page 2013/01/18 Ed 1 Setup and Programming manual for XTIP series SETUP MANUAL FOR XTIP SERIES 3G PANEL *THIS SYSTEM REQUIRES A CMA/XMB/XMA/WMB or TMT2 INSTALLER SOFTWARE FOR PROGRAMMING* **TO TRANSMIT ALARMS AND VIDEO VIA ETHERNET, THE SYSTEM REQUIRES AN EXTERNAL POWER SUPPLY WITH 4 ALKALINE BATTERIES FOR BACK-UP (PP4)** XT Initial Programming Open the Control Panel Using a #1 Phillips screwdriver, remove the 2 screws holding the cover on. The cover will fold off the panel like a book with the curved side acting like the binding. The same technique is used when placing the cover back onto the unit. 1375 Willow Lake Blvd. #103 Vadnais Heights, MN 55110 6|Page 2013/01/18 Ed 1 Setup and Programming manual for XTIP series *The SIM card must NOT be inserted or removed while the panel is powered* Install the SIM card Slide SIM card into the slot. Make sure it is aligned correctly. The SIM card is not required if you plan to use Ethernet only. Connect the RJ45 (Ethernet cable) to the panel Plug the RJ45 cable into the Ethernet jack on the control panel. The cable can be routed back through the wire channel to make sure it does not get pinched. Important: When the panel attempts a transmission via Ethernet a red LED will flash. Obtaining XMB/XMA/WMB Keypad Special Characters Obtaining CMA Keypad Special Characters 1375 Willow Lake Blvd. #103 Vadnais Heights, MN 55110 7|Page 2013/01/18 Ed 1 Setup and Programming manual for XTIP series Powering the Panel **THE CONTROL PANEL MUST BE CONNECTED TO AN EXTERAL POWER SUPPLY WHEN ETHERNET FEATURE IS ACTIVE** Option 1: PP1 4 x LSH20 SAFT Lithium D-Cell Used for Standalone or Xtender mode without Programmable Inputs, Programmable Outputs, Ethernet, or SMS LSH20 Specifications: Operating Temp: -76°F to +230°F Storage Temp: Dry, Ventilated, 86°F Max LSH20 Technical Specifications Nominal Voltage 3.6 V Open Circuit Voltage 3.67 V Nominal Capacity 9.3 Ah Option 2 4 x E95VP Alkaline D-Cell + 12v 2amp DC Class 2 power supply (not supplied) Used for Standalone or Xtender mode where Programmable Inputs/Mapping, Programmable Outputs, Ethernet connection, or SMS will be used E95VP Specifications: Operating Temp: 0°F to 130°F E95VP Technical Specifications Nominal Capacity 8900 mA hours Nominal Voltage 1.5 V Power Supply Requirements Output Voltage (volts) 12 Output Current (mA) 2000 Class 2 (For UL Certifications Compliance) WARNINGS: 1. 2. DO NOT USE ALKALINE BATTERIES IF INSTALLING AN XTIP BELOW 30° F DO NOT INSTALL A TRANSFORMER WHEN USING OPTION 1 (LITHIUM BATTERIES). 1375 Willow Lake Blvd. #103 Vadnais Heights, MN 55110 8|Page 2013/01/18 Ed 1 Setup and Programming manual for XTIP series XTIP Programming Reset the XTIP Panel: Press and hold programming button () for 10sec until the Indicator LED blinks twice Press and instantly release the programming button (). The indicator LED will blink once. The panel is now in ‘Learn Mode’ for the CMA601/XMB-XMA-WMB611 keypad. *Note: If you are having issues pairing the keypad to the panel, please refer to the troubleshooting section. Insert all three batteries into the CMA/XMB/XMA/WMB and press both the ESC/NO and CLR keys at the same time and release. The indicator LED on the keypad will blink rapidly. Programming Device/Keypad RSI (c)20## www.RsiAlarm.co or <======XX====== CLR & ESC/NO KEYPAD 1 RECORDED YES/OK Other languages are available by scrolling with arrows. ITALIANO, NEDERLANDS, DEUTSCH, CASTELLANO, SVENSKA, PORTUGUES, FRANCAIS Press YES/OK for the selected one. <- LANGUAGE : > ENGLISH or 1375 Willow Lake Blvd. #103 Vadnais Heights, MN 55110 for language selection YES/OK to apply 9|Page 2013/01/18 Ed 1 Setup and Programming manual for XTIP series The Radio Range test must be run during device recording to ensure proper pairing with the control panel. This tests the number of successful pings between the device and the control panel. The keypad will display a real time RF level for the device that is being tested. This test will run until stopped and should be run for at least 30 seconds to receive accurate results. RADIO RANGE TEST ? YES/OK RF TEST x/9 The RF level must be 9/9 for reliable transmission. RADIO RANGE TEST ? YES/OK ESC/NO Wait while the screen changes From here until the end of initial programming you will not be able to step back to a previous parameter. All parameters can be changed after initial programming has been completed. ENTER THE INSTALLER CODE 4 TO 6 DIGITS THEN YES/OK INSTALLER CODE: Use the Alphanumeric Keypad to enter the Installer Code *This code is important to keep track of. There is no back door to the system INSTALLER CODE: xxxx CONFIRM CODE RE-ENTER CODE YES/OK CONFIRM CODE xxxx You may name the installer code using the Alphanumeric Keypad. If you leave the name blank it will default to ‘ACCESS 1’ CODE NAME: YES/OK ACCESS 1 ENTRY COMPLETE Wait while the screen changes ADJUSTING TIME AND DATE DATE (Year) : 09/ / Use the or DATE (Year) : 10/ / to set the Year DATE (Month) : 10/01/ Use the or YES/OK DATE (Month) : 10/11/ to set the Month 1375 Willow Lake Blvd. #103 Vadnais Heights, MN 55110 10 | P a g e 2013/01/18 Ed 1 Setup and Programming manual for XTIP series YES/OK Use the or DATE (Day) : 09/06/01 to set the Day DATE (Day) : 09/06/03 YES/OK Use the or to set the Hour – The system uses a 24 hour clock. TIME (HOUR) : 00:00 TIME (HOUR) : 10:00 Use the or DATE (Minutes) 10:00 to set the Minutes DATE (Minutes) 10:53 YES/OK 03/06/09 10:53 ENTRY COMPLETE YOU MUST ALWAYS CHOOSE ‘YES/OK’ Use the Alphanumeric Keypad to enter in a 4-8 digit account number provided by the Central Station CONNECTED TO MONITOR.STATION YES/OK ACCOUNT NUMBER? ACCOUNT NUMBER:99865123 Other periods are available: 48 hours, 24 hours, 12 hours,1 hour, No Test Use arrows for the selection and press YES/OK to confirm. *We suggest at least a 24 hour test PERIODIC TEST: 24 HOURS or and Use the arrow keys + YES/OK to choose the Hour and Minute the periodic test will happen. YES/OK for period selection YES/OK to apply TEST HOUR: 00:00 TEST MINUTE: 00:00 1375 Willow Lake Blvd. #103 Vadnais Heights, MN 55110 11 | P a g e 2013/01/18 Ed 1 Setup and Programming manual for XTIP series CODE/STATE modification CODE/STATE MODIFICATION? These are the default transmitted events: Device Alarm Alert Alarm Initialization Not Transmitted Panel Batteries Alarm/End AC Power Alarm/End Phoneline Fault Not Transmitted Tamper Alarm/End Device Batt. Alarm/End Radio Jamming Not Transmitted Supervision Alarm/End Periodic Test Alarm Wrong Codes Not Transmitted Duress Code Alarm Alarm Memory Not Transmitted Arm/Disarm Not Transmitted Fire Alarm Medical Assist Alarm Ethernet Alarm/End If you would like to change the state YES/OK TRANS. STATE MODIFICATION YES/OK List of all events ESC/NO ESC/NO TRANS. STATE MODIFICATION to toggle press YES/OK and use the or between: Alarm – Appearance Alarm/End – Appearance and Restoral Not Transmitted – Not Transmitted ESC/NO SERVER ADDRESSES? Your IP1 address is given to you by your Central Station. YES/OK IP 1 ADDRESS YES/OK YES/OK to enter into the parameter and use the Keypad to complete the address. Press YES/OK to confirm your entry and the arrow to move to the next Press IP1 ADDRESS: xxx.xxx.xxx.xxx parameter. *You will use either an IP address or a Domain Name but not both *When entering an IP address you must enter all 12 digits including preceding zeros. Your Domain Name is given to you by your Central Station. YES/OK DOMAIN NAME 1 YES/OK to enter into the parameter and use the Keypad to complete the name. Press YES/OK to confirm your entry and the arrow to move to the next Press parameter. *You will use either an IP address or a Domain Name but not both leave it blank if an IP has already been entered. The Port is given to you by your Central Station. By default the panel will use 888. If you need to modify the port press YES/O DOMAIN NAME 1: xxxxx.xxx.xxx YES/OK PORT 1 YES/OK YES/OK key to enter into the parameter and the keypad to complete the port. Press YES/OK to confirm and the arrow to move to the next parameter. the PORT 1: xxx Continue through IP2 and TMT IP. Once you have entered all valid parameters press ESC/NO to return to the main menu then ESC/NO again to move to the next parameter. ESC/NO SERVER ADDRESSES? ESC/NO 1375 Willow Lake Blvd. #103 Vadnais Heights, MN 55110 12 | P a g e 2013/01/18 Ed 1 Setup and Programming manual for XTIP series Press right arrow to select the transmission mode for alarms and videos and YES/OK to confirm. 1. Ethernet transmission with 2G3G back-up 2. Ethernet transmission only 3. 2G3G transmission only STRATEGY ETH+2G3G YES /OK STRATEGY: ETH YES/OK Warning: the transmission mode “Ethernet only” is not recommended. STRATEGY: 2G3G 2G3G PARAMETERS ? YES/OK Your APN code (Access Point Name) is given to you by your Cellular Provider. Press YES/OK to enter into the parameter and use the Keypad to complete the code. Press APN CODE YES/OK to confirm your entry and the arrow to move to the next parameter. Your USERNAME is given to you by your Cellular Provider. YES/OK to enter into the parameter and use the Keypad to complete the name. Press YES/OK to confirm your entry and the arrow to move to the next USERNAME Press PASSWORD YES/OK to enter into the parameter and use the Keypad to complete the name. Press YES/OK to Press confirm your entry and ESC/NO followed by ESC/NO again to get back to programming. Videofied will require a 3/5 or better for reliable transmission of Video alarms YES/OK YES/OK YES/OK YES/OK PASSWORD: xxxxxxxxxxxx 2G3G PARAMETERS ? During the 2G3G Level test the Modem will boot and attempt to gain access to the cellular network. The system will display either a signal level out of 5 or an error code. Error codes are listed in the troubleshooting section. To keep the keypad awake, use any key on the keypad except the YES/OK, ESC/NO, and CLR keys. This test can take up to 5 minutes. Once the level or error has posted press YES/OK to continue in programming. *For explanation of 2G3G errors see bottom of page 16. APN CODE: xxxxx.xxxxxx.xx USERNAME: xxxxxxxxxxx parameter. Your PASSWORD is given to you by your Cellular Provider. YES/OK 2G3G LEVEL? ESC/NO YES/OK TEST IN PROGRESS YES/OK = END 2G3G LEVEL x/5 YES/OK 1375 Willow Lake Blvd. #103 Vadnais Heights, MN 55110 13 | P a g e 2013/01/18 Ed 1 Setup and Programming manual for XTIP series ETHERNET PARAMETERS DHCP: ENABLE OR DISABLE OU INACTIF DISABLE PANEL IP • These parameters are not necessary if you choose DHCP ENABLE • These parameters are the local network parameters. It’s necessary to configure all these parameters if DHCP is disabled. IP MASK ENABLE GATEWAY IMPORTANT: Verify that the IP address selected is available on the Network. PRIMARY DNS SECONDARY DNS ETHERNET PARAMETERS? During this test, the panel tries to connect to the local Ethernet Network. The result of this test can be: If the connection is successful: the local IP of the panel will be displayed (with right arrow you can display other Ethernet parameters – IP Mask, primary & secondary, Gateway). ESC/NO ETH. STATUS? TEST IN PROGRESS OK/YES/OK = END ETHERNET OFF NO STATUS: the Ethernet module is switched off. Please verify that the Ethernet cable is connected and try again. CABLE OR NETWORK ABSENT: the panel doesn’t detect Ethernet Cable or Network. YES/OK PANEL IP xxx.xxx.xxx.xxx ETH. STATUS? DHCP ERROR: the panel is not able to get an IP from the DHCP. DHCP may be enabled but the network may not have a DHCP lease available. 1375 Willow Lake Blvd. #103 Vadnais Heights, MN 55110 ESC/NO 14 | P a g e 2013/01/18 Ed 1 Setup and Programming manual for XTIP series Enter the name of the logical area 1 + YES/OK. Repeat this step for areas 2, 3, 4. Refer to page 4 for more information. AREAS CONFIGURATION Press ESC/NO if you want to let default value. Note: Areas are designed to define logical separation between groups of devices. AREA NAME 1: ARMING OPTION: Your choice will depend on how you are arming the system. From the host: Will make the XT a piggyback/xtender system that arms and disarms off the latching of 9-12v on the arming inputs. ARMING OPTION: Standalone ARMING OPTION: From the host Standalone: Will make the XT a solo system controlled by arming and disarming using Videofied peripheral devices. Other values are available: 2 min, 1 min, 45 sec Use the arrows for the selection and YES/OK to confirm. Other values are available: 2 min, 1 min, 45 sec, 30 sec, 15 sec Use the arrows for the selection and YES/OK to confirm. EXIT DELAY: 45 Sec ENTRY DELAY: 15 Sec Go to Page 15 to continue with standalone programming Using the control panel in the FROM THE HOST mode will only be able to arm and disarm by latching 9-12v to one of the two inputs. Wiring diagrams available on page 26. Arming input 1 will control the arming and disarming of devices in areas 1 and 2. Where devices in area 1 are subject to the Entry Delay. Arming input 2 will control the arming and disarming of devices in areas 3 and 4. Where devices in area 3 are subject to the Entry Delay. ARMING OPTION : From The Host Mode Slow : Used for following the arming and disarming of the host system. This will arm each device one at a time conserving battery life. MODE: Slow YES/OK Mode Fast : Used to instant arm all devices while sacrificing battery life. YES/OK YESMODE: /OK Fast YES/OK ENTRY DELAY Enter the value for your Entry Delay up to 255 seconds and press YES/OK. VALUE:(0-255) (000): 1375 Willow Lake Blvd. #103 Vadnais Heights, MN 55110 15 | P a g e 2013/01/18 Ed 1 Setup and Programming manual for XTIP series By entering a value using the keypad, up to 600 seconds, the transmission of any event will be delayed that many seconds. Enter the value you would like for the Transmission Delay and press YES/OK TRANSMISSION DELAY Value: (0-600) (000): YES/OK Arming Confirmation is the number of seconds the system will wait to arm after voltage is latched on the arming input. This feature can be used as an exit delay. Enter the value you would like for the Arming Confirmation and press ARMING CONFIRMATION YES/OK Value: (0-240) (0): YES/OK RECORDING DEVICES Each device has a unique programming button. Please reference the Installation Sheet for the device you would like to program. PRESS PROGRAM BUTTON OF DEVICE *Note: If you are having issues pairing a device to the panel, please refer to the troubleshooting section. Press YES/OK on Radio Range Test? You must allow the Radio Range test to run for at least 30 seconds (9/9) before stopping the test by pressing YES/OK. YES/OK (Device Type) # Recorded RADIO RANGE TEST? RF TEST x/9 Press ESC/NO if first Radio Range Test was successful. Use the arrow keys to select the proper area. Devices that need an entry/exit delay should be set to AREA 1. Devices that must be instant trigger should be AREA 2, 3, or 4. Press YES/OK. RADIO RANGE TEST? AREA ALLOCATION: NAME LOCATION: FUNCTIONAL DEVICE TEST? ENTERING A NEW DEVICE? YES/OK or ESC/NO CLOSE THE PANEL Before completing programming make sure that all tampers are depressed by verifying that each devices indicator LED is off. OPERATION COMPLETED? 1375 Willow Lake Blvd. #103 Vadnais Heights, MN 55110 YES/OK 16 | P a g e 2013/01/18 Ed 1 Setup and Programming manual for XTIP series Device Installation DCV651 – Outdoor MotionViewer / BR651 Outdoor Badge Reader Place batteries in Device. Wait for LED to turn on. Press and release the programming button. DCV601 – Indoor MotionViewer / ITR601 – Indoor Blind PIR Place batteries in device. Wait for LED to turn on behind PIR lens. Press and release the programming button. DCV601 ITR601 CT601 – Door/Window Contact Place battery into the door/window contact. Wait for LED to turn on. Press and release the programming button. RC601 – Remote Control Fob Press and hold the ON and OFF keys at the same time for 5 counts of Mississippi and release. SE651/601 – Indoor and Outdoor Sirens Place all batteries into the siren. Wait for the LED to turn on right above the programming button. Press and release the programming button. 1375 Willow Lake Blvd. #103 Vadnais Heights, MN 55110 17 | P a g e 2013/01/18 Ed 1 Setup and Programming manual for XTIP series How to Disable/Enable Monitoring Disabling monitoring can be a useful tool in many situations. Before mounting devices and moving the panel to find a good GPRS / 3G level, disabling monitoring will ensure that you will have access to programming and that unnecessary signals are not sent to the monitoring station. When performing maintenance on the system disabling monitoring until the issue has been resolved will ensure that you will have access to programming throughout your troubleshooting. Press the arrow to move to ACCESS LVL. 10/12/27 10:53 DISARMED LVL:1 ACCESS LEVEL Use your arrow keys to change the level to 4 YES/OK ACCESS LVL: 4 YES/OK Enter the installer code for the system. If a level 3 code is entered in the system you will be required to authenticate with that code as well. Press the BADGE OR CODE **** CONFIGURATION to move to CONFIGURATION YES/OK GENERAL PARAMETERS to move to CONFIGURATION MONITOR. Use the STATION CONFIGURATION MONITOR. STATION YES/OK Press YES/OK on MONITORING PARAMETERS MONITORING PARAMETERS Press YES/OK on MONITORING ENABLED and use the to change the value to DISABLED and press YES/OK to lock it in. Press and hold ESC/NO for 5 seconds to return to the main menu. MONITORING ENABLED YES/OK MONITORING: DISABLED YES/OK 1375 Willow Lake Blvd. #103 Vadnais Heights, MN 55110 18 | P a g e 2013/01/18 Ed 1 Setup and Programming manual for XTIP series Entering a Badge or Access Code for Arming/Disarming After Initial programming has been completed, you are not able to arm and disarm the system until you enter a user code or badge (the installer code cannot arm and disarm the system). Codes can th be 4-6 digits and the 4 digit must be 2 values higher or lower than any other code on the system: Example: User code 1234, next code cannot be 1235, 1236, 1233, or 1232 – These are reserved for Silent Duress and Audible Duress. The XT system can accept up to 19 Badges or Access codes in any combination. You must first change the access level to 4. Right Arrow to Access Level and press YES/OK. Use the arrow keys to move to Level 4 and press YES/OK. When prompted with Badge Or Code enter the installer code followed by YES/OK. Press the 10/12/27 10:53 DISARMED LVL:1 ACCESS LEVEL: YES/OK BADGE OR CODE **** arrow to move to BADGES ACCESS CODES. BADGES ACCESS CODES YES/OK ENTER A BADGE/CODE YES/OK Enter a 4-6 digit user code or present a badge to the reader for 2 seconds. BADGE OR CODE: **** YES/OK Confirm the code by re-entering. Badge Presented CONFIRM THE CODE: YES/OK Use the keypad to name the badge or code or leave it blank for the default name: ACCESS #. CODE NAME: NAME OF BADGE: YES/OK YES/OK ENTRY COMPLETE If you are entering any additional codes press YES/OK. If you have completed entering Badges and Codes press and hold ESC/NO for 5 seconds to return to the main menu. 000000 Reserved codes ENTER A BADGE/CODE Reserved codes Reserved codes From 9998 to 9999 All codes +1 From 99998 to 99999 All codes +2 From 999898 to 999999 All codes -1 From 314157 to 314159 All codes – 2 A total of 186 codes are forbidden 1375 Willow Lake Blvd. #103 Vadnais Heights, MN 55110 19 | P a g e 2013/01/18 Ed 1 Setup and Programming manual for XTIP series Access level Definition & rights LVL1 Stand by level LVL2 Restricted USER level where it is only possible to arm/disarm the system. LVL3 USER level where it is possible to arm/disarm the system, check the event log, test the devices. Modifications of the setting are not possible at this level. User LVL3 can create LVL3 or LVL2 access codes. INSTALLER level where it is possible to modify the setup of the panel. The approval of a LVL3 or LVL2 is required to modify the level for LVL4. LVL4 Installer LVL4 can create the first LVL3 access code only. Configuration of Special Arming Modes: To configure or modify a special arming mode, with the direction arrow go to the menu: CONFIGURATION (LEVEL 4) + [YES/OK] ALARM MODES PROGRAMMABLE + [YES/OK] FULLY ARMED, SP1 and SP2 (use direction arrows to select the arming mode you want to modify + [YES/OK]). For each arming mode, it is possible to specify how each of the 4 areas will be armed and how the system will behave during an alarm. Areas: States: 1 2 3 4 press the corresponding number to change that areas arming option A A A A state for the respective area. Press the [YES/OK] key after this configuration step. The system will then display what siren mode will be in effect for this special profile. Select the siren mode using the direction arrows then press [YES/OK]. Armed Disarmed Perimeter Devices Only External Devices Only (devices must be programmed) (devices must be programmed) Siren Delay beeps Silent Without Siren Immediate triggering of all sirens Entry/Exit delay beeps, then triggering of the sirens No Sirens, No Beeps Beeps on the keypad only 1375 Willow Lake Blvd. #103 Vadnais Heights, MN 55110 20 | P a g e 2013/01/18 Ed 1 Setup and Programming manual for XTIP series ETHERNET Parameters: nging Siren Options To configure or modify Ethernet Parameters, go to: CONFIGURATION (level 4) + [YES/OK] >> GENERAL PARAMETERS + [YES/OK] >> ETHERNET + After initial programming has been completed any sounder on the system will be enabled by default, [YES/OK] this includes the sounder on the Keypad and Badge Reader. While there is no way to disable the of the exit delay you are able to disable the intrusion sound. sounding IP Parameters: 1. DHCP Enable – IP address is assigned by the DHCP service on the network. 2. DHCP Disable – IP address must be defined in Ethernet parameters. IP address will NOT be automatically obtained from DHCP service on the network. Constant Ethernet: 1. “Auto” Mode - We recommend this mode. If main powered, the panel will be connected constantly to the local Network. In case of an alarm, the alarm will be sent in few seconds to the monitoring station. When the main power is cut, the Ethernet module will switch off after a delay (DELAY BEFORE OFF – 30 by default) in order to save battery life. In case of an alarm, the panel will at first connect to the local Network. It adds few seconds to the total process of sending an alarm. 2. “ON” Mode - The panel will be connected constantly to the local Network. This option will impact back-up battery life. 3. “OFF” Mode - For each transmission of alarm and video, the panel will connect to the local Network. PING REPLY: Enables ping response Time Out Server: In case of disconnection to the local Network, the panel will try after that time to re-connect. Max Seg. Size: Size of packet sent Codes Action 999999 Maintenance request - GPRS / 3G transmission 999996 Maintenance request - Ethernet transmission Displays local IP address assigned to the control panel: 999995 If the DHCP mode is deactivated : the static local IP of the panel will be displayed (defined in the ETHERNET menu – 7) If the DHCP is activated: How to test to the center dispatch If the panel is not in transmission then 0.0.0.0 will be displayed If the panel is in transmission (the RJ45 led will be flashing) then the dynamic IP of the panel will be displayed. Testing to the dispatch is done twice during installation. Once while you are programming the Sends alarm to IP1 (Primary alarm receiver)Although both will use the system and then again once thea test installation hasAddress been completely finished. a quick to check forusing connectivity to the monitoring If there is a same 999991 steps the initial testThis willisbe just way confirmation one device to verifycenter. the programming. transmission problem the panel will terminate communication faster than in an actual alarm. The system will automatically attempt connection to IP2 Address (Backup alarm receiver) in the event that IP1 is unavailable. How to Disable Monitoring 999997 Displays external power supply status Disabling monitoring can be a useful tool in many situations. Before mounting devices and moving the panel to find a good GPRS level, disabling monitoring will ensure that you will have access to programming and that unnecessary signals are not sent to the monitoring station. When performing maintenance on the system disabling monitoring until the issue has been resolved will ensure that you will have access to programming throughout your troubleshooting. 1375 Willow Lake Blvd. #103 Vadnais Heights, MN 55110 21 | P a g e 2013/01/18 Ed 1 Setup and Programming manual for XTIP series GPRS / 3G for deployment of panel Before the system is mounted you will need to check the GPRS / 3G level to make sure it is adequate. If the level is 3/5 or better you can mount the control panel in that location. GPRS/3G Level EVENT LOG 010 11 SIM card not detected/not inserted 043 44 Provisioning problem 132 133 SIM card not activated 255 256 Cannot connect to cell tower 003 SIM Card not detected/No Cellular Service 030 31 No Cellular Service 101 Authentication Error 102 Low Cellular Signal 47 Rejection by Host 013 Incorrect APN Code 13 Press the No Cellular Service 149 Fix Error SIM Card not detected arrow to move to MAINTENANCE. Power down control panel and check SIM card orientation and contacts Contact the cellular provider to check provisioning and activation Check with the cellular provider on SIM activation Check coverage maps, bring panel outdoors to test, Check coverage maps, power down control panel and check SIM card orientation and contacts Check coverage maps or with cellular provider for outages Check that the APN entered in the system is correct Check coverage maps, move the panel outdoors to test, check with cellular provider for outages Attempt a Yagi antenna installation to improve strength IP, Domain Name, Port are incorrect or Receiver is rejecting the signal Check with provider for proper APN information Power down control panel and check SIM orientation and contacts 10/12/27 10:53 DISARMED LVL:1 YES/OK Press the MAINTENANCE arrow to move to 2G3G LEVEL. Press YES/OK on 2G3G LEVEL to start the test. 2G3G LEVEL This test can take up to 5 minutes to complete. Pressing the YES/OK, ESC/NO, or CLR buttons will prematurely end the test. This test will automatically issue the results to the display of the keypad when it has completed with either a level out of 5 (0/5-5/5) or an error code (listed below). Use the arrow keys to keep the keypad awake during the test. TEST IN PROG. YES/OK = END 2G3G LEVEL X/5 Press and hold ESC/NO for 5 seconds to return to the main menu. 2G3G LEVEL 1375 Willow Lake Blvd. #103 Vadnais Heights, MN 55110 YES/OK 22 | P a g e 2013/01/18 Ed 1 Setup and Programming manual for XTIP series How to test RF for deployment of devices Running the RF test during the mounting of devices is key to a successful Videofied installation. This test will ensure that all devices have adequate communication with the control panel. All Videofied devices are bi-directional which allows the system to ping the device and expect a response. The number of successful responses out of 9 will be displayed on the keypad for the device you are running the test for. This is also a When in Access Level 3 or higher press the move to MAINTENANCE Press the arrow to 10/12/27 10:53 DISARMED LVL:3 YES/OK MAINTENANCE arrow to move to DEVICE LOCATING Press YES/OK on DEVICE LOCATING to get to the list of devices. Use the arrow keys to find the device you would like to run the test for. DEVICE LOCATING YES/OK (DEVICE NAME) This test will run as long as you need it to. Pressing the YES/OK, ESC/NO, or CLR buttons will end the test. This test will show the results on the display of the keypad relative to the number of successful pings to the panel. It is required to run the test for at least 30 seconds at the mounting location for accurate results and to have a 9/9 for reliable transmission of alarms and video. Press YES/OK when you are finished with the test. Press and hold ESC/NO for 5 seconds to return to the main menu. RF TEST 0/9 YES/OK YES/OK (DEVICE NAME) Once all devices are checking in at 9/9, you are ready to test the full system to your central station. After arming and tripping each device call the central station and verify alarm and video of each device with dispatch. Now you are ready to show the customer how to use the system. relative range that will change in real time as you walk further away from the control panel and back closer. 1375 Willow Lake Blvd. #103 Vadnais Heights, MN 55110 23 | P a g e 2013/01/18 Ed 1 Setup and Programming manual for XTIP series XTIP Power Chart 1375 Willow Lake Blvd. #103 Vadnais Heights, MN 55110 24 | P a g e 2013/01/18 Ed 1 Setup and Programming manual for XTIP series Arming Input Wiring Diagram When in the ‘Arm From Host’ mode the Videofied system will only arm and disarm when 9-12v is supplied and sustained. When both arming inputs are supplied voltage at the same time the Videofied Keypad display will show ‘SYSTEM ARMED. When only one arming input is supplied voltage the Videofied Keypad display will show ‘PART LVL #’ Arming Input 1 will arm/disarm Areas 1 & 2 Arming Input 2 will arm/disarm Areas 3 & 4 1375 Willow Lake Blvd. #103 Vadnais Heights, MN 55110 25 | P a g e 2013/01/18 Ed 1 Setup and Programming manual for XTIP series How to test to the dispatch center Testing to the dispatch is done twice during installation. Once while you are programming the system and then again once the installation has been completely finished. Although both will use the same steps the initial test will be just confirmation using one device to verify the programming. 10/12/27 10:53 DISARMED LVL:1 Enter a User code and press YES/OK or present a badge to the reader. 10/12/27 10:53 **** YES/OK The system will sound the exit delay through the keypad and badge reader. Once the delay has expired and the keypad says SYSTEM ARMED, put motion in front of a MotionViewer. If the MotionViewer is in area 1 you will need to wait for the entry delay to expire before disarming the system. Once the system has gone into alarm enter a User Code followed by YES/OK or present a badge to the reader to disarm. ARMING THE SYSTEM SYSTEM ARMED SYSTEM ARMED **** The display will tell you that there has been an intrusion since the last time the system was armed. Press YES/OK to continue. INTRUSION DETECTED YES/OK YES/OK After pressing YES/OK the keypad will tell you which device has been triggered. Press YES/OK to continue. (DEVICE NAME) (AREA) YES/OK The system will go back to the main menu automatically but will not allow you to move around in programming until the system has disconnected from the central station. 10/12/27 10:53 DISARMED LVL:1 To verify that the system has transmitted you must contact the Dispatch Center and have the account information ready Note: Send 1 MotionViewer in at a time and verify with Central Station that they are getting Alarm and Video before tripping another MotionViewer. This will save time with the Central Station. 1375 Willow Lake Blvd. #103 Vadnais Heights, MN 55110 26 | P a g e 2013/01/18 Ed 1 Setup and Programming manual for XTIP series How to mount the XTIP How to Mount the Control Panel? Fix the back casing on the wall with 3 screws () 1375 Willow Lake Blvd. #103 Vadnais Heights, MN 55110 27 | P a g e 2013/01/18 Ed 1 Setup and Programming manual for XTIP series General Programmable Input Configuration 1375 Willow Lake Blvd. #103 Vadnais Heights, MN 55110 28 | P a g e 2013/01/18 Ed 1 Setup and Programming manual for XTIP series 1375 Willow Lake Blvd. #103 Vadnais Heights, MN 55110 29 | P a g e 2013/01/18 Ed 1 Setup and Programming manual for XTIP series 1375 Willow Lake Blvd. #103 Vadnais Heights, MN 55110 30 | P a g e 2013/01/18 Ed 1 Setup and Programming manual for XTIP series General Programmable Output Configuration 1375 Willow Lake Blvd. #103 Vadnais Heights, MN 55110 31 | P a g e 2013/01/18 Ed 1 Setup and Programming manual for XTIP series 1375 Willow Lake Blvd. #103 Vadnais Heights, MN 55110 32 | P a g e 2013/01/18 Ed 1 Setup and Programming manual for XTIP series 1375 Willow Lake Blvd. #103 Vadnais Heights, MN 55110 33 | P a g e 2013/01/18 Ed 1 Setup and Programming manual for XTIP series Scheduling Configuration 1375 Willow Lake Blvd. #103 Vadnais Heights, MN 55110 34 | P a g e 2013/01/18 Ed 1 Setup and Programming manual for XTIP series 1375 Willow Lake Blvd. #103 Vadnais Heights, MN 55110 35 | P a g e 2013/01/18 Ed 1 Setup and Programming manual for XTIP series 1375 Willow Lake Blvd. #103 Vadnais Heights, MN 55110 36 | P a g e 2013/01/18 Ed 1 Setup and Programming manual for XTIP series Troubleshooting Monitoring Station is not getting ANY video but is getting signals: Good communication between the MotionViewers and the Control Panel is key to getting successful video to the monitoring station. During mounting of any device on your Videofied system you must run the Radio Range/Device Locating test to ensure that the mounting location is with-in range of the Control Panel. Concrete, Metal and earth are some of the largest RF inhibitors and should be taken into account when choosing mounting locations. When running the Radio Range/Device Locating test you should have the site as close to the same as it would be when the site is closed/no one is there, i.e. close garage doors/service doors, etc. Device locating steps can be found on Page 17. Devices are not sending Video clips YES/OK – There are faulty devices Check Maintenance/ Display Faulty Devices NO – There are no faulty devices MotionViewers come up with ‘Radio Problem’. This means that the MotionViewers are currently not talking with the Control Panel. Run Maintenance/ Device Locating Device Locating will test the RF signal strength between the device and the Control Panel. For reliable transmission this result must be a 9/ 9. This is the number of successful pings between the device and the Control Panel so a loss of just 1 packet could cause failure to transmit video. Bring the devices back to the Control Panel and hit the programming button to force them to sync back with the panel. Important Note: Videofied will only automatically download the first MotionViewer video that is taken and only if this is the primary event or reason for the panel connecting with the monitoring station. If the account is on test you will only ever get the first video downloaded. If you are only getting the events at the station and all tests above pass more than likely you are sending a preceding event (like an arming signal or door contact) which will cause the video to not auto download because the video is not the primary event. 1375 Willow Lake Blvd. #103 Vadnais Heights, MN 55110 37 | P a g e 2013/01/18 Ed 1 Setup and Programming manual for XTIP series Monitoring Station is not getting any signals: Communication between the Control Panel and the Monitoring Station is either over the Ethernet Connection or GPRS / 3G side of the GSM cellular network. Go into Maintenance and run the ETH STATUS to see if you receive back an IP Address or error. If you receive an IP Address back you will want to contact and consult the network admin to make sure the outbound port is not being blocked (Port 1 programmed in the panel). If you are using GPRS / 3G as the primary communication, you will want to check your GPRS / 3G level to see if there is an error/level is too low. You must have a 3/5 or better for reliable transmission to the Monitoring Station. How to run the GPRS / 3G level test and GPRS / 3G error codes can be found on page 16. If you receive a successful GPRS / 3G level test you will want to check the panel event log for more GPRS / 3G errors that could be occurring during the attempted transmission but after cellular authentication. 2G3G 2G3G ERROR 2G3G erors can be found on page 16 of the manual 2G3G 2G3G Level 3/5 – 5/5 2G3G 2G3G Level 0/5 – 2/5 2G3G 2G3G Panel is staying CONNECTED WITH MONITOR STATION While the Control Panel is attempting or is connected with the Monitoring Station you will see this message when you attempt to move around on the keypad. If the system is not successful in connecting with the station it will retry the connection multiple times, locking you out of programming until it is done trying. This normally can take anywhere between 15-20 minutes. If you want to force the panel to disconnect you must o 1. Remove the batteries from the control panel o 2. Secure the cover tamper of the panel o 3. Re-insert the batteries into the control panel and sync the keypad back by pressing the CLR and ESC/NO buttons at the same time. o 4. Access the Configuration menu by changing you access level to 4 and go to Configuration Monitor Station. o 5. In Monitoring Parameters – Disable monitoring until the connection issue is resolved. 1375 Willow Lake Blvd. #103 Vadnais Heights, MN 55110 38 | P a g e 2013/01/18 Ed 1 Setup and Programming manual for XTIP series Unable to record device or getting ‘Pairing Failure’ error This usually occurs when the device still has a pairing key from a previous system or setup. To perform a pairing key override: 1. Remove all batteries from the device. 2. Make sure your system is ready to record devices: o A. If learning in the keypad, press the panel’s programming button. DO NOT HOLD THE PANEL’S PROGRAMMING BUTTON o B. If learning in additional devices, make sure the keypad reads ‘Press Programming Button Of Device’ 3. Insert a single battery into the device. 4. Wait 1 second for device to power up. 5. Press programming button of device (for keypads press ‘CLR’ & ‘ESC/NO’ keys at the same time) For the 4-button remote keyfobs the process is slightly different: o 1. Press and hold the ‘ON’ and ‘OFF’ keys at the same time for 12 seconds o 2. Wait 1 second o 3. Press and hold the ‘ON’ and ‘OFF’ keys at the same time for 5 seconds, you should hear 4 beeps from the keyfob. Outdoor MotionViewer Trips All the Time: It is important to follow these basic installation tips when mounting and aiming an outdoor MotionViewer o 1. Protect your assets, not the whole area. Secure specific assets or clusters of assets rather than cover a large area where the range of the MotionViewer might extend beyond the assets and detect irrelevant objects. o 2. Terminate the view of the MotionViewer. Make sure to tilt the MotionViewer down 5-7° so that its top line of sight terminates into the ground. Taking into account all three elements; PIR, digital video camera, and infrared illuminators – you will want to terminate the view of the MotionViewer at 40 ft. from the device. 1375 Willow Lake Blvd. #103 Vadnais Heights, MN 55110 39 | P a g e 2013/01/18 Ed 1 Setup and Programming manual for XTIP series XTIP -SERIES ‘AFTER INITIAL PROGRAMMING’ FLOW CHART Parameters are only available in Access Level 4 1375 Willow Lake Blvd. #103 Vadnais Heights, MN 55110 40 | P a g e 2013/01/18 Ed 1 Setup and Programming manual for XTIP series 1375 Willow Lake Blvd. #103 Vadnais Heights, MN 55110 41 | P a g e 2013/01/18 Ed 1 Setup and Programming manual for XTIP series Addendum 1. LSH20 Control Panel Batteries: 2. LS14500 Peripheral Batteries: Excludes SE601 and SE651 3. Lithium Battery Storage: 1375 Willow Lake Blvd. #103 Vadnais Heights, MN 55110 42 | P a g e 2013/01/18 Ed 1 Setup and Programming manual for XTIP series 4. Finding Manufacture Week and Year: The Manufacture week and year can be found in the serial number of the device/control panel. The second sets of 4 numbers in the serial number are WWYY. ####0411######## = Which shows that this device was manufactured in the 4th week of 2011. 5. Event Log Ethernet Codes Log Code Ethernet Off Ethernet On Ethernet (0) Ethernet (1) Ethernet (2) Ethernet (255) Ethernet Lost Ethernet Returned Meaning Ethernet interface is OFF Ethernet interface is ON Ethernet Error No DCHP reply (after MAX DHCP RETRY) No Frontel reply (after TIMEOUT SERVER) Ethernet communication success No Ethernet cable detected Ethernet cable restored 6. Additional System Codes Codes Action 999999 Maintenance request - GPRS / 3G transmission 999996 Maintenance request - Ethernet transmission Displays local IP address assigned to the control panel: 999995 If the DHCP mode is deactivated : the static local IP of the panel will be displayed (defined in the ETHERNET menu – 7) If the DHCP is activated: If the panel is not in transmission then 0.0.0.0 will be displayed If the panel is in transmission (the RJ45 led will be flashing) then the dynamic IP of the panel will be displayed. 999991 999997 Sends a test alarm to IP1 Address (Primary alarm receiver) This is a quick way to check for connectivity to the monitoring center. If there is a transmission problem the panel will terminate communication faster than in an actual alarm. The system will automatically attempt connection to IP2 Address (Backup alarm receiver) in the event that IP1 is unavailable. Displays external power supply status 1375 Willow Lake Blvd. #103 Vadnais Heights, MN 55110 43 | P a g e
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : Yes Create Date : 2013:05:17 10:40:43+02:00 Creator : Microsoft® Word 2010 Modify Date : 2013:06:11 15:08:56+02:00 Language : fr-FR Tagged PDF : Yes XMP Toolkit : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:08:04 Creator Tool : Microsoft® Word 2010 Metadata Date : 2013:06:11 15:08:56+02:00 Producer : Microsoft® Word 2010 Format : application/pdf Document ID : uuid:28f3d156-6ca7-4dce-a957-7188920bbbb5 Instance ID : uuid:431fe973-d77c-4cc3-adb3-36a37d844f58 Page Count : 43EXIF Metadata provided by EXIF.tools