Rachio RFLOW Wireless Flow Meter User Manual Rachio 3 Flow Meter V4 5

Rachio, Inc. Wireless Flow Meter Rachio 3 Flow Meter V4 5

Contents

Rachio 3 Flow Meter User Manual V4.5

Download: Rachio RFLOW Wireless Flow Meter User Manual Rachio 3 Flow Meter  V4 5
Mirror Download [FCC.gov]Rachio RFLOW Wireless Flow Meter User Manual Rachio 3 Flow Meter  V4 5
Document ID3847576
Application IDQkh5pQs7fniHvEDKyHxiNg==
Document DescriptionRachio 3 Flow Meter User Manual V4.5
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize31.48kB (393512 bits)
Date Submitted2018-05-11 00:00:00
Date Available2018-05-30 00:00:00
Creation Date2018-04-17 15:17:34
Producing SoftwareAdobe PDF Library 15.0
Document Lastmod2018-04-17 20:44:03
Document TitleRachio 3 Flow Meter User Manual V4.5
Document CreatorAdobe InDesign CC 13.1 (Macintosh)

WIRELESS FLOW METER
Let’s get started.
What’s in the box.
What you’ll need.
Installation instructions are intended only for use
with recommended fittings. Visit rachio.com/flow
for a list of required tools, helpful videos, FAQs
and more.
Recommended fittings
Recommended manual pipe cutter
Wireless Flow Meter
Sandpaper or deburring tool
Fine point permanent marker
Stick ruler
Phillips screwdriver
Smartphone or tablet
Battery Cover
4 Screws
2 AA Batteries
Before you get started.
Before any pipe is cut, make sure your system meets
the installation requirements:
Installation site must be within 300 feet of an
installed Rachio 3 Smart Sprinkler Controller.
Backflow preventer and installation area must
be above ground (recommended).
Below ground installation requires additional steps
not included in this manual. For more information,
visit rachio.com/flow-underground .
The Flow Meter is not rated for potable water and
must be installed after the backflow preventer.
System must have ¾ inch or 1 inch pipe made
of either copper, PVC, PEX, or SDR9 poly.
For 1 inch PVC pipe, 1 inch copper or poly pipe,
and ¾ inch PVC pipe, you will need 14 inches of
straight pipe between the backflow preventer and
valve box.
For ¾ inch copper or poly pipe, you will need
16 inches of straight pipe between the backflow
preventer and valve box.
If you have more than one Rachio 3 controller
or more than one backflow preventer, visit
rachio.com/flow-advanced.
Need some help?
IMPORTANT: Using installation methods other than
those recommended in this manual could damage
the Wireless Flow Meter or void the warranty.
WARNING: Inserting your fingers into the Flow
Meter or fittings can damage equipment or cause
personal injury.
Once attached, fittings cannot be removed from
the Flow Meter, but may be removed from the pipe
using fitting removers.
Using glue of any kind could damage the Rachio
Flow Meter.
Check out our Help Center.
Give us a call.
support.rachio.com
1 (855) 300 3569
If you’re unable to complete any of the installation
steps, we recommend a professional installation.
To find a Rachio Pro, go to rachio.com/flow-install.
STEP 1
Pair flow meter.
STEP 2
Turn water off.
Take the Wireless Flow Meter to the backflow
preventer where it will be installed.
Turn off water to the irrigation system at the
backflow or at the main shut-off.
Do not put the batteries in the Flow Meter
until prompted.
Drain the system by running any zone for one
minute using the Quick Run feature in the
Rachio App.
Open the Rachio app. From the “More” tab, select
“Accessories,” then add the Rachio Wireless
Flow Meter. You will be guided through the
pairing process and then prompted to continue
installation.
STEP 3
Connect fittings.
Push the Flow Meter and fittings together firmly
using a twisting action until the fittings are flush
or nearly flush with the Flow Meter.
10
11
STEP 4
Find your measurements.
Use the chart on the next page to find the
size and material of your system. Reference
the matching pipe cutting instructions in the
following pages to mark pipes in preparation
for cutting.
Accuracy is important here!
Measure twice, cut once.
If you are not using the Rachio-recommended
fittings, please use your fittings’ specs to
complete installation.
12
For copper or poly pipe.
¾ in
1 in
Page 14
Page 16
For PVC or PEX pipe.
¾ in
1 in
Page 18
Page 18
13
Instructions for cutting
3/4 inch copper or poly pipe.
Backflow Preventer
1. Identify 16 inches of straight pipe between
the backflow preventer and the valve box.
6”
2. Mark 6 inches after the backflow; this will be
the top cut (red line).
3. Mark 8 ½ inches after the first mark; this will
be the bottom cut (red line).
16”
8.5”
4. Put a small X next to the first two marks.
5. Mark 1 ⅛ inches above the top mark to
indicate insertion depth (white line).
Valve Box
6. Mark 1 ⅛ inches below the bottom mark to
indicate insertion depth (white line).
14
Bottom fitting can be buried
up to 2 inches if needed.
15
Instructions for cutting
1 inch copper or poly pipe.
Backflow Preventer
1. Identify 14 inches of straight pipe between
the backflow preventer and the valve box.
6”
2. Mark 6 inches after the backflow; this will be
the top cut (red line).
3. Mark 6¼ inches after the first mark; this will
be the bottom cut (red line).
14”
6.25”
4. Put a small X next to the first two marks.
5. Mark 1 ⅛ inches above the top mark to
indicate insertion depth (white line).
6. Mark 1 ⅛ inches below the bottom mark to
indicate insertion depth (white line).
16
Valve Box
Bottom fitting can be buried
up to 1 inch if needed.
17
Instructions for cutting ¾ inch
and 1 inch PVC or PEX pipe.
Backflow Preventer
1. Identify 14 inches of straight pipe between
the backflow preventer and the valve box.
6”
2. Mark 6 inches after the backflow; this will be
the top cut (red line).
3. Mark 6½ inches after the first mark; this will
be the bottom cut (red line).
14”
6.5”
4. Put a small X next to the first two marks.
5. Mark 1 inches above the top mark to indicate
insertion depth (white line).
6. Mark 1 inches below the bottom mark to
indicate insertion depth (white line).
18
Valve Box
Bottom fitting can be buried
up to 1 inch if needed.
19
STEP 5
Cut and clean pipe.
Backflow Preventer
Make a clean, straight cut on the two
innermost marks (denoted with X’s).
First, cut the top innermost mark.
Next, cut the bottom innermost mark.
Do not cut the pipe on the outer
insertion marks.
Use the deburring tool or sandpaper
to remove rough edges and debris
inside and outside the pipe.
Valve Box
20
21
STEP 6
Install the flow meter.
Backflow Preventer
Install so the arrows on the side and face
of the Flow Meter are oriented with the
direction of water flow.
(Water flows towards the valve box.)
Push the Flow Meter, fittings, and pipe
together firmly while twisting the fittings to
the insertion marks (white lines).
All Rachio recommended fittings swivel 360˚,
allowing for easy directional adjustment of
the Flow Meter after installation.
Valve Box
22
23
STEP 7
Turn water on.
Congrats, you did it!
Turn the water back on.
Your Flow Meter is now reporting actual water usage.
Check installation site for leaks. If there is a leak,
turn the water off and make sure the fittings are
pushed up to the body of the flow meter and
insertion marks. If the leak cannot be remedied,
visit rachio.com/flow-leak.
To enable real-time leak detection, calibrate the
Rachio Wireless Flow Meter. In the app’s “More” tab,
select “Accessories,” then select the Rachio Wireless
Flow Meter. Follow the app instructions to calibrate.
Check your email for tips on monitoring water flow and
leak detection with your Rachio Wireless Flow Meter.
24
25
©2018 Rachio, Inc.

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : Yes
Language                        : en-US
Tagged PDF                      : Yes
XMP Toolkit                     : Adobe XMP Core 5.6-c015 84.159810, 2016/09/10-02:41:30
Create Date                     : 2018:04:17 15:17:34-06:00
Metadata Date                   : 2018:04:17 20:44:03-06:00
Modify Date                     : 2018:04:17 20:44:03-06:00
Creator Tool                    : Adobe InDesign CC 13.1 (Macintosh)
Instance ID                     : uuid:6bb6f7b1-45a6-4aa9-b1f3-d742b4f5123f
Original Document ID            : xmp.did:52529cad-706f-42e2-bd43-f30746bc2b5a
Document ID                     : xmp.id:31b49266-f392-42e6-b92a-6d709f3969fb
Rendition Class                 : proof:pdf
Derived From Instance ID        : xmp.iid:e7dd8ccb-8be0-4d9b-a607-0d4fb38019ba
Derived From Document ID        : xmp.did:1053a089-9c12-4cf8-aab4-a05d660ea61f
Derived From Original Document ID: xmp.did:52529cad-706f-42e2-bd43-f30746bc2b5a
Derived From Rendition Class    : default
History Action                  : converted
History Parameters              : from application/x-indesign to application/pdf
History Software Agent          : Adobe InDesign CC 13.1 (Macintosh)
History Changed                 : /
History When                    : 2018:04:17 15:17:35-06:00
Format                          : application/pdf
Producer                        : Adobe PDF Library 15.0
Trapped                         : False
Page Count                      : 14
Creator                         : Adobe InDesign CC 13.1 (Macintosh)
EXIF Metadata provided by EXIF.tools
FCC ID Filing: 2AOTBRFLOW

Navigation menu