Radwin AMWL1000 Hybrid System Tranmceiver User Manual AirMux 200 fm

Radwin Ltd. Hybrid System Tranmceiver AirMux 200 fm

Manual revised

AirMux-200 Installation and Operation ManualPoint-to-Point Wireless TDM/IP Multiplexer
  AirMux-200 Point-to-Point Wireless TDM/IP Multiplexer Installation and Operation Manual    Notice This manual contains information that is proprietary to RAD Data Communications Ltd. ("RAD").  No part of this publication may be reproduced in any form whatsoever without prior written approval by RAD Data Communications. Right, title and interest, all information, copyrights, patents, know-how, trade secrets and other intellectual property or other proprietary rights relating to this manual and to the AirMux-200 and any software components contained therein are proprietary products of RAD protected under international copyright law and shall be and remain solely with RAD. AirMux-200 is a registered trademark of RAD. No right, license, or interest to such trademark is granted hereunder, and you agree that no such right, license, or interest shall be asserted by you with respect to such trademark. You shall not copy, reverse compile or reverse assemble all or any portion of the Manual or the AirMux-200. You are prohibited from, and shall not, directly or indirectly, develop, market, distribute, license, or sell any product that supports substantially similar functionality as the AirMux-200, based on or derived in any way from the AirMux-200. Your undertaking in this paragraph shall survive the termination of this Agreement. This Agreement is effective upon your opening of the AirMux-200 package and shall continue until terminated. RAD may terminate this Agreement upon the breach by you of any term hereof. Upon such termination by RAD, you agree to return to RAD the AirMux-200 and all copies and portions thereof. For further information contact RAD at the address below or contact your local distributor.
  International Headquarters  RAD Data Communications Ltd.   24 Raoul Wallenberg St. Tel Aviv 69719 Israel Tel: 972-3-6458181 Fax: 972-3-6498250 E-mail: rad@rad.com U.S. Headquarters  RAD Data Communications Inc.  900 Corporate Drive Mahwah, NJ 07430 USA Tel: (201) 529-1100, Toll free: 1-800-444-7234 Fax: (201) 529-5777 E-mail: market@radusa.com    © 2002–2004 RAD Data Communications Ltd. Publication No. xxx-200-05/04 Limited Warranty  RAD warrants to DISTRIBUTOR that the hardware in the AirMux-200 to be delivered hereunder shall be free of defects in material and workmanship under normal use and service for a period of twelve (12) months following the date of shipment to DISTRIBUTOR.  If, during the warranty period, any component part of the equipment becomes defective by reason of material or workmanship, and DISTRIBUTOR immediately notifies RAD of such defect, RAD shall have the option to choose the appropriate corrective action: a) supply a replacement part, or b) request return of equipment to its plant for repair, or c) perform necessary repair at the equipment's location.  In the event that RAD requests the return of equipment, each party shall pay one-way shipping costs. RAD shall be released from all obligations under its warranty in the event that the equipment has been subjected to misuse, neglect, accident or improper installation, or if repairs or modifications were made by persons other than RAD's own authorized service personnel, unless such repairs by others were made with the written consent of RAD. The above warranty is in lieu of all other warranties, expressed or implied.  There are no warranties which extend beyond the face hereof, including, but not limited to, warranties of merchantability and fitness for a particular purpose, and in no event shall RAD be liable for consequential damages. RAD shall not be liable to any person for any special or indirect damages, including, but not limited to, lost profits from any cause whatsoever arising from or in any way connected with the manufacture, sale, handling, repair, maintenance or use of the
  AirMux-200, and in no event shall RAD's liability exceed the purchase price of the AirMux-200. DISTRIBUTOR shall be responsible to its customers for any and all warranties which it makes relating to AirMux-200 and for ensuring that replacements and other adjustments required in connection with the said warranties are satisfactory. Software components in the AirMux-200 are provided "as is" and without warranty of any kind.  RAD disclaims all warranties including the implied warranties of merchantability and fitness for a particular purpose.  RAD shall not be liable for any loss of use, interruption of business or indirect, special, incidental or consequential damages of any kind.  In spite of the above RAD shall do its best to provide error-free software products and shall offer free Software updates during the warranty period under this Agreement. RAD's cumulative liability to you or any other party for any loss or damages resulting from any claims, demands, or actions arising out of or relating to this Agreement and the AirMux-200 shall not exceed the sum paid to RAD for the purchase of the AirMux-200. In no event shall RAD be liable for any indirect, incidental, consequential, special, or exemplary damages or lost profits, even if RAD has been advised of the possibility of such damages. This Agreement shall be construed and governed in accordance with the laws of the State of Israel.
  General Safety Instructions The following instructions serve as a general guide for the safe installation and operation of telecommunications products. Additional instructions, if applicable, are included inside the manual. Safety Symbols  This symbol may appear on the equipment or in the text. It indicates potential safety hazards regarding product operation or maintenance to operator or service personnel.     Danger of electric shock! Avoid any contact with the marked surface while the product is energized or connected to outdoor telecommunication lines.   .  Protective earth: the marked lug or terminal should be connected to the building protective earth bus.      Some products may be equipped with a laser diode. In such cases, a label with the laser class and other warnings as applicable will be attached near the optical transmitter. The laser warning symbol may be also attached.  Please observe the following precautions: •  Before turning on the equipment, make sure that the fiber optic cable is intact and is connected to the transmitter. •  Do not attempt to adjust the laser drive current. •  Do not use broken or unterminated fiber-optic cables/connectors or look straight at the laser beam. •  The use of optical devices with the equipment will increase eye hazard. Warning Warning
  •  Use of controls, adjustments or performing procedures other than those specified herein, may result in hazardous radiation exposure. ATTENTION:  The laser beam may be invisible!  Always observe standard safety precautions during installation, operation and maintenance of this product. Only qualified and authorized service personnel should carry out adjustment, maintenance or repairs to this product. No installation, adjustment, maintenance or repairs should be performed by either the operator or the user.
  Handling Energized Products  General Safety Practices  Do not touch or tamper with the power supply when the power cord is connected. Line voltages may be present inside certain products even when the power switch (if installed) is in the OFF position or a fuse is blown. For DC-powered products, although the voltages levels are usually not hazardous, energy hazards may still exist. Before working on equipment connected to power lines or telecommunication lines, remove jewelry or any other metallic object that may come into contact with energized parts.  Unless otherwise specified, all products are intended to be grounded during normal use. Grounding is provided by connecting the mains plug to a wall socket with a protective earth terminal. If an earth lug is provided on the product, it should be connected to the protective earth at all times, by a wire with a diameter of 18 AWG or wider. Rack-mounted equipment should be mounted only in earthed racks and cabinets. Always make the ground connection first and disconnect it last. Do not connect telecommunication cables to ungrounded equipment. Make sure that all other cables are disconnected before disconnecting the ground. Connection of AC Mains Make sure that the electrical installation complies with local codes. Always connect the AC plug to a wall socket with a protective ground. The maximum permissible current capability of the branch distribution circuit that supplies power to the product is 16A. The circuit breaker in the building installation should have high breaking capacity and must operate at short-circuit current exceeding 35A. Always connect the power cord first to the equipment and then to the wall socket. If a power switch is provided in the equipment, set it to the OFF position. If the power cord cannot be readily disconnected in case of emergency, make sure that a readily accessible circuit breaker or emergency switch is installed in the building installation. Connection of DC Mains Unless otherwise specified in the manual, the DC input to the equipment is floating in reference to the ground. Any single pole can be externally grounded. Due to the high current capability of DC mains systems, care should be taken when connecting the DC supply to avoid short-circuits and fire hazards. DC units should be installed in a restricted access area, i.e. an area where access is authorized only to qualified service and maintenance personnel.
  Make sure that the DC supply is electrically isolated from any AC source and that the installation complies with the local codes. The maximum permissible current capability of the branch distribution circuit that supplies power to the product is 16A. The circuit breaker in the building installation should have high breaking capacity and must operate at short-circuit current exceeding 35A. Before connecting the DC supply wires, ensure that power is removed form the DC circuit. Locate the circuit breaker of the panel board that services the equipment and switch it to the OFF position. When connecting the DC supply wires, first connect the ground wire to the corresponding terminal, then the positive pole and last the negative pole. Switch the circuit breaker back to the ON position. A readily accessible disconnect device that is suitably rated and approved should be incorporated in the building installation. Installing the Radio Terminals (RTs) The following safety measures apply when installing the radio terminals and masts. •  Mast / pole / towers should comply with local standards such as BS6651. •  Only trained professional installers should install or dismantle radio terminals and masts. The installer is responsible for meeting all building and safety codes. •  Before installing a terminal, make sure it is disconnected from power. •  A safety belt and climbing harness must be used when installing the radio terminals on a mast or tower. •  Masts of height 3 meters or more must be guyed according to required industry standards and be lightning protected. •  If a radio terminal is to be mounted at a height of more than 4 meters above the roof, it is recommended that a climbable tower be installed to give access to the equipment and to prevent antenna movement during strong winds. •  When installing equipment, beware of overhead high-voltage power lines. Never install a mast under power lines. •  The mast structure must be grounded. •  Do not stand in front of a live radio terminal. •  The installer should configure the output power level of antennas according to country regulations and per antenna type. •  The antenna used for this transmitter must be installed to provide a separation distance of at least 200 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter.
   Outdoor units and antennas should be installed ONLY by experienced installation professionals who are familiar with local building and safety codes and, wherever applicable, are licensed by the appropriate government regulatory authorities. Failure to do so may void the AirMux-200 warranty and may expose the end user or the service provider to legal and financial liabilities. RAD and its resellers or distributors are not liable for injury, damage or violation of regulations associated with the installation of outdoor units or antennas.  Protection Against Lightning Activity Observe the following safety measures to protect personnel and equipment: •  All outdoor equipment must be attached to a properly grounded structure, and installed masts must be grounded, in order to provide protection against lightening, surges and static buildup. In addition, mast over 3 meters should have a lightning protection rod. Failure to do so creates a safety risk and will void the equipment warranty. •  Do not work on the system or connect or disconnect the cables prior to or during electrical storm activity. •  In case of an electrical storm, do not touch any outdoor electrical equipment and leave the roof as quickly as possible. Warning
  Connection of Data and Telecommunications Cables Data and telecommunication interfaces are classified according to their safety status. The following table lists the status of several standard interfaces. If the status of a given port differs from the standard one, a notice will be given in the manual.  Ports Safety Status V.11, V.28, V.35, V.36, RS-530, X.21, 10 BaseT, 100 BaseT, Unbalanced E1, E2, E3, STM, DS-2, DS-3, S-Interface ISDN, Analog voice E&M  SELV Safety Extra Low Voltage:  Ports which do not present a safety hazard. Usually  up to 30 VAC or 60 VDC. xDSL (without feeding voltage), Balanced E1, T1, Sub E1/T1  TNV-1 Telecommunication Network Voltage-1:  Ports whose normal operating voltage is within the  limits of SELV, on which overvoltages from telecommunications networks are possible. FXS (Foreign Exchange Subscriber)  TNV-2 Telecommunication Network Voltage-2:  Ports whose normal operating voltage exceeds the  limits of SELV (usually up to 120 VDC or telephone  ringing voltages), on which overvoltages from  telecommunication networks are not possible. These  ports are not permitted to be directly connected to  external telephone and data lines. FXO (Foreign Exchange Office), xDSL (with feeding voltage), U-Interface ISDN TNV-3  Telecommunication Network Voltage-3:  Ports whose normal operating voltage exceeds the  limits of SELV (usually up to 120 VDC or telephone  ringing voltages), on which overvoltages from  telecommunication networks are possible.   The signals between the IDU and ODU are TNV-1.   Always connect a given port to a port of the same safety status. If in doubt, seek the assistance of a qualified safety engineer. Note
  Always make sure that the equipment is grounded before connecting telecommunication cables. Do not disconnect the ground connection before disconnecting all telecommunications cables. Some SELV and non-SELV circuits use the same connectors. Use caution when connecting cables. Extra caution should be exercised during thunderstorms. When using shielded or coaxial cables, verify that there is a good ground connection at both ends. The earthing and bonding of the ground connections should comply with the local codes.  The telecommunication wiring in the building may be damaged or present a fire hazard in case of contact between exposed external wires and the AC power lines. In order to reduce the risk, there are restrictions on the diameter of wires in the telecom cables, between the equipment and the mating connectors.
    To reduce the risk of fire, use only No. 26 AWG or larger telecommunication line cords.    Pour réduire les risques s’incendie, utiliser seulement des conducteurs de télécommunications 26 AWG ou de section supérieure.  Some ports are suitable for connection to intra-building or non-exposed wiring or cabling only. In such cases, a notice will be given in the installation instructions. Do not attempt to tamper with any carrier-provided equipment or connection hardware. Electromagnetic Compatibility (EMC) The equipment is designed and approved to comply with the electromagnetic regulations of major regulatory bodies. The following instructions may enhance the performance of the equipment and will provide better protection against excessive emission and better immunity against disturbances. A good earth connection is essential. When installing the equipment in a rack, make sure to remove all traces of paint from the mounting points. Use suitable lock-washers and torque. If an external grounding lug is provided, connect it to the earth bus using braided wire as short as possible. The equipment is designed to comply with EMC requirements when connecting it with unshielded twisted pair (UTP) cables. However, the use of shielded wires is always recommended, especially for high-rate data. In some cases, when unshielded wires are used, ferrite cores should be installed on certain cables. In such cases, special instructions are provided in the manual. Disconnect all wires which are not in permanent use, such as cables used for one-time configuration. The compliance of the equipment with the regulations for conducted emission on the data lines is dependent on the cable quality. The emission is tested for UTP with 80 dB longitudinal conversion loss (LCL). Unless otherwise specified or described in the manual, TNV-1 and TNV-3 ports provide secondary protection against surges on the data lines. Primary protectors should be provided in the building installation. The equipment is designed to provide adequate protection against electro-static discharge (ESD). However, it is good working practice to use caution when connecting cables terminated with plastic connectors (without a grounded metal hood, such as flat CautionAttention
  cables) to sensitive data lines. Before connecting such cables, discharge yourself by touching earth ground or wear an ESD preventive wrist strap. FCC-15 User Information This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: -- Reorient or relocate the receiving antenna. -- Increase the separation between the equipment and receiver. -- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help.  Changes or modifications to this equipment not expressly approved by the party responsible for compliance (RAD) could void the user’s authority to operate the equipment.   It is the responsibility of the installer to ensure that when using the outdoor antenna kits in the United States (or where FCC rules apply), only those antennas certified with the product are used. The use of any antenna other than those certified with the product is expressly forbidden in accordance to FCC rules CFR47 part 15.204.     Warning
  Canadian Emission Requirements for the IDU This Class A digital apparatus meets all the requirements of the Canadian Interference-Causing Equipment Regulation. Cet appareil numérique de la classe A respecte toutes les exigences du Règlement sur le matériel brouilleur du Canada. Warning per EN 55022 (CISPR-22) for the IDU  This is a class A product. In a domestic environment, this product may cause radio interference, in which case the user will be required to take adequate measures.   Cet appareil est un appareil de Classe A. Dans un environnement résidentiel, cet appareil peut provoquer des brouillages radioélectriques. Dans ces cas, il peut être demandé à l’utilisateur de prendre les mesures appropriées.   Dieses ist ein Gerät der Funkstörgrenzwertklasse A. In Wohnbereichen können bei Betrieb dieses Gerätes Rundfunkströrungen auftreten, in welchen Fällen der Benutzer für entsprechende Gegenmaßnahmen verantwortlich ist.     Statement according to Directive 1999/5/EC Hereby, RAD Data Communications Ltd. declares that the AirMux-200 system is in compliance with the essential requirements and other relevant provisions of Directive 1995/5/EC.  The alert sign on the AirMux-200 indicates that the frequency band that is being used by the equipment is not harmonized within the EU and/or the potential restrictions on its use are applicable in one or more EU member states.  Warning        Avertissement  Achtung
 Installing AirMux-200 Units 1 Quick Start Guide  Installation of AirMux-200 should be carried out only by a qualified technician. If you are familiar with AirMux-200, use this guide to prepare the units for operation. 1. Installing AirMux-200 Units ODU Package Contents: § ODU § Mast/Wall mounting kit § Mounting instructions § RJ-45 Connector § Hermetic Cable Enclosure § AIRMUX-200 Manager installation CD IDU Package Contents: § IDU § RJ-45 Connector § Wall mounting drilling template § 110V/220V desk mount adaptor Equipment Required: § RJ-45 Crimp Tool § Wall mounting hardware. Ordered separately (To wall mount IDU, use screws with head diameter of 6.3mm max) § Drill § IDU grounding cable § 13 mm or 1/2” socket spanner
Quick Start Guide  AirMux-200 Installation and Operation Manual 2 Installing AirMux-200 Units  § ODU/IDU Cable (Outdoor class, CAT-5e, 4 twisted pairs) § UV-rated cable ties § Laptop running Windows 2000 or Windows XP Before the installation 1. Install the AirMux-200 software on the laptop. 2. Verify that all equipment and tools are available Performing Outdoor Installation ä  To install the ODU: 1. Route the ODU cable from the ODU location (on the roof) to the IDU location (inside the building). 2. Mount the ODU unit to the mast or wall, using the mounting kit. 3. Connect the RJ-45 connectors to both ends of the cable, use the pinout table below:   IDU RJ-45 Wire Color ODU RJ-45 Function 1 White/Green 1 Twisted  2 Green 2 3 White/Orange 3 Twisted  6 Orange 6 Ethernet 4 Blue 4 Twisted  5 White\Blue 5 7 White/Brown 7 Twisted  8 Brown 8 Power  4. Secure the ODU and ground cables to the mast or brackets using UV-rated cable ties. 5. Repeat the procedure at the remote site. ä  To align the ODU: 1. Connect power to the IDU. Warning
AirMux-200 Installation and Operation Manual  Quick Start Guide  Operating AirMux-200 3  Do not stand in front of a live radio terminal.  2. Align the local ODU in the direction of the remote ODU. Turn the ODU slowly using the buzzer beep sequence until optimal alignment is achieved: 3. Repeat step 2 for the remote ODU to complete the alignment procedure. 4. Make sure that the management station is properly connected to the local IDU, and the AirMux Manager application is running. 5. Open the installation wizard and follow the installation steps 6. After selection of the radio channel and the link rate, verify the link quality is at least in the yellow area for Ethernet service and in the green area for TDM service.  Try to achieve the best possible link quality values. In case of radio link loss, verify the ODU alignment, or change the radio channel in both sides of the link. When the radio link resumes continue the installation process.  7. Monitor the link quality for about 15 minutes to verify stability. 8. Permanently attach the local and remote ODU to the mast/wall. Performing Indoor Installation ä  To connect user equipment to the IDU: 1. Connect user mux or PBX to the IDU rear panel RJ-45 port designated Trunk. 2. Connect user hub/router or any other compatible device to the IDU rear-panel RJ-45 port designated LAN. 2. Operating AirMux-200 AirMux-200 requires no operator attention once installed, with the exception of occasional monitoring of front panel indicators and statistics data. Intervention is only required when AirMux-200 must be configured to its operational requirements or diagnostic tests are performed. Note
Quick Start Guide  AirMux-200 Installation and Operation Manual 4 Operating AirMux-200  Normal Indications Upon turning on AirMux-200, the PWR LED in the front panel lights to indicate that AirMux-200 is on. The table below shows the correct status of the indicators a few seconds after power-up. Indicator Status PWR ON RTCB Green – Blinking slowly RT Green – Blinking slowly Air Green – Blinking slowly Service Green – Blinking slowly Troubleshooting 1. PWR LED is off – Check that AC adapter is connected to the IDU and the AC power outlet 2. RTCB LED is yellow – Check that the IDU/ODU cable is properly wired and connected 3. RT LED is red – Check that the IDU/ODU cable is properly wired and connected 4. Air LED is yellow – Complete the installation procedure from the management software. 5. Air LED is RED – Check the ODU Antenna alignment. Check that the radio configuration of both local and remote units are the same (channel and SSID) 6. Service LED is off – Check the TDM service configuration in the NMS  7. Service LED is yellow – Check that the system is not in loop-back mode. Check the remote RTCB ports and cables and remote external equipment. 8. Service led is red – check the local IDU ports, cables and external equipment
 Overview 1-1 Chapter   1 Introduction 1.1 Overview AirMux-200 is a carrier-class, high capacity, low cost Point-to-Point broadband wireless transmission system. AirMux-200 packs Legacy TDM and Ethernet services over 5.725-5.850 GHz license-exempt bands and is suitable for deployment in FCC or ESTI regulated countries over a 48 Mbps wireless link at distances of up 80 km (50 miles). Application Figure   1-1 illustrates a typical point-to-point application of two AirMux-200 units. PBXLANLANEthernetEthernetAirMux-200Up to 80 km (50 miles)AirMux-200 PBXE1/T1E1/T1 Figure   1-1.  Typical Application Features Wireless Link AirMux-200 delivers a 48 Mbps channel for Ethernet traffic, excluding inband (TDMoIP) E1/T1 streams. AirMux-200 operates as a line-of-sight radio system supporting the following frequency bands: •  ANSI Unlicensed National Information Infrastructure (UNII) •  ISM.
Chapter 1  Introduction  AirMux-200 Installation and Operation Manual 1-2 Overview  AirMux-200 can be configured to operate over several frequency channels with a carrier step resolution of 10 MHz. The number of the frequency channels depends on the selected operating band. AirMux-200 uses Direct Sequence Spread Spectrum technology combined with powerful forward error correction to ensure high reliability and security over license exempt 5.725–5.850 GHz frequencies. AirMux-200 operation complies with the FCC 15.401&15.407 requirements. AirMux-200 employs Time Division Duplex (TDD) transmission. This technology simplifies the installation and configuration procedure. There is no need to plan and to allocate separate channels for the uplink and downlink data streams.  Operation over 5.725–5.850 GHz bands is not affected by harsh weather conditions, such as fog, heavy rain etc. LAN Interface The AirMux-200 LAN port provides two 10/100BaseT interfaces with autonegotiation and transparent VLAN support. Traffic handling is provided by a MAC-level self-learning bridge. TDM Interface The AirMux-200 TDM interface accepts E1 or T1 traffic, supporting the following: •  Framed and unframed operation (E1 and T1) •  ESF and SF framing (T1) •  AMI and B8ZS zero suppression (T1) •  CRC-4 bits generation (E1) •  Flexible timeslot allocation (framed E1 and T1). Management AirMux-200 has full local and remote management capabilities. The user-friendly SNMP-based management tool provides full end-to-end configuration and performance monitoring capabilities.  Diagnostics and Performance Monitoring AirMux-200 supports activating local and remote loopbacks on E1 or T1 links.
AirMux-200 Installation and Operation Manual Chapter 1  Introduction  Overview 1-3 AirMux-200 constantly monitors the data transmission process, evaluates received signal strength, signal-to-noise ratio and bit error rate. It also monitors received traffic and frame rate (FPS) for local and remote units. Optional External Antenna An optional planar array 28 dBi external antenna increases the operation range of AirMux-200 to 80 km (50 miles).
Chapter 1  Introduction  AirMux-200 Installation and Operation Manual 1-4 Physical Description  1.2 Physical Description AirMux-200 system consists of a radio terminal (ODU) and an indoor unit (IDU). Figure   1-2 illustrates an AirMux-200 unit assembly.  Figure   1-2.  AirMux-200 Unit The front panel of the indoor unit (IDU) includes five LEDs, which display the status of E1/T1, wireless link, self-test results, ODU-to-IDU link, and power status. For a detailed description of the front panel, see Chapter 4. The rear panel of the indoor unit (IDU) includes the power, user (WAN, LAN and E1 or T1), and radio terminal connectors. The AirMux-200 rear panel is described in detail in Chapter 3.
AirMux-200 Installation and Operation Manual Chapter 1  Introduction  Technical Specifications 1-5 1.3 Technical Specifications Wireless Link Technology  Spread spectrum  Frequency Band  5.725–5.850 GHz: •  ANSI Unlicensed National Information Infrastructure (UNNII) •  ISM  Duplexing Method  Time Division Duplex (TDD)  Capacity  Configurable up to 48 Mbps (See Table   1-1)  Modulation  OFDM - BPSK, QPSK, 16QAM, 64QAM  Channel Bandwidth Resolution  10 MHz  Transmitter Power FCC: 21.4 dBm max ETSI: 7 dBm max (limited by ETSI regulations)  Receiver Sensitivity  –90 dBm at BER 1E-8  Antenna Gain  22 dBi  Antenna Beam   ±9° horizontal and vertical  Range  80 km (50 miles), including 6 dB fade margin  ODU Installation Method  Mast or wall mounting LAN InterfacePHY IF  10/100BaseT, auto-sensing  Framing/Coding  IEEE 802.3/U  Bridging  Self-learning, up to 2000 MAC addresses  Line Impedance  100Ω  VLAN Support  Transparent  Data Rate  48 Mbps max.  Connector  RJ-45 E1 Interface Framing  G.703, G.704 with or without CRC  Data Rate  Unframed (Transparent) 2.048MHz
Chapter 1  Introduction  AirMux-200 Installation and Operation Manual 1-6 Technical Specifications   Timing  Plesiochronous   Connector  RJ-45 T1 Interface Zero Suppression  AMI, B8ZS  Framing  SF, ESF  Connector  RJ-45
AirMux-200 Installation and Operation Manual Chapter 1  Introduction  Technical Specifications 1-7 External Antenna Type  Planar array  Gain  28 dBi min  VSWR  1.7:1 max  F/B Ratio  -40 dB max  Compliance  ETSI EN 302 085 V1.1.2 (2001-02)  Polarization  Linear (vertical or horizontal)  Input Impedance  50Ω  Lightning Protection  DC-grounded  Connector  N-type, female  Range  Up to 80 km (50 miles), including 6 dB fade margin Indicators  PWR (green)  Power status  ODU (green/red)  ODU-to-IDU link status  IDU (green)  IDU self-test results  AIR I/F (green/red)  Wireless link status  Service (green/red)  E1/T1 signal status Power  Source  100–240 VAC via external AC/DC converter  Power Received by the ODU (PoE)  -48 VDC  Power Consumption 20W max (ODU and IDU)  Connector  2-pin  Physical  Outdoor Unit (ODU) with integrated antenna   Height    305 mm /  12 in  Width    305 mm /  12 in  Depth      58 mm / 2.3 in  Weight     3.3 kg    / 7.2 lb  Indoor Unit (IDU-E)
Chapter 1  Introduction  AirMux-200 Installation and Operation Manual 1-8 Technical Specifications   Height    44 mm / 1.7 in (1U)  Width  237 mm / 9.3 in  Depth  170 mm / 6.7 in  Weight  0.58 kg   / 1.4 lb
AirMux-200 Installation and Operation Manual Chapter 1  Introduction  Technical Specifications 1-9  External Antenna (Optional)    Height    600 mm / 23.6 in  Width    600 mm / 23.6 in  Depth      51 mm /      2 in  Weight        5 kg    /   11 lb Environment Outdoor Unit (ODU)   Enclosure  All-weather case  Temperature  -35 to 60°C/-31 to 140°F  Indoor Unit (IDU)   Temperature  -5 to 45°C/23 to 113°F  Humidity  Up to 90%, non-condensing  Table   1-1.  Throughput/Capacity Rate (MHz) Throughput Mbps at 5km full duplex Capacity E1         T1  Integrated Antenna (km) External Antenna (km) 12 4.5 1 1 26 40 18 7 2 2 18 40 36 13 2 2 8 26 48 17 2 2 3 9
 AirMux-200 System 2-1 Chapter   2 Installation and Setup This chapter describes installation and setup procedures for AirMux-200 system. After installing the unit, refer to Chapter 3 for configuration instructions. In case a problem is encountered, refer to Chapter 5 for test and diagnostic instructions.  Internal settings, adjustment, maintenance, and repairs may be performed only by a skilled technician who is aware of the hazards involved. Always observe standard safety precautions during installation, operation, and maintenance of this product.  2.1 AirMux-200 System AirMux-200 system comprises the following units: •  Outdoor Unit (ODU): An enclosed aluminum frame with a front sealed plastic cover, containing an integrated transceiver with an antenna, RF module, modem and standard interfaces. The ODU stores all the configuration parameters of the AirMux-200 system. ODU includes a power connector, which receives -48 VDC, and RJ-45 for Ethernet (including PoE) traffic from the indoor unit (IDU). The ODU is attached to a mast using a special mounting kit, which is supplied with the unit. •  Indoor Unit (IDU): The interface unit between the ODU and the user. It converts 220 VAC to -48VDC, and sends it on to the ODU. The IDU does not store any configuration data. Therefore there is no need for additional configuration of the AirMux-200 system when replacing an IDU. Warning
Chapter   2  Installation and Setup  AirMux-200 Installation and Operation Manual 2-2 Installation and Setup  2.2 Site Requirements and Prerequisites For the IDU, allow at least 90 cm (36 in) of frontal clearance for operating and maintenance accessibility. Allow at least 10 cm (4 in) clearance at the rear of the unit for signal lines and interface cables. The ambient operating temperature should be –45 to 60°C/-49 to 140°F (ODU), or -5 to 45°C/23 to 113°F (IDU) at a relative humidity of up to 90%, non-condensing. 2.3 Package Contents The AirMux-200 package includes the following items: •  ODU (Outdoor Unit) •  IDU (Indoor Unit) •  ODU cable pre-cut to length ordered •  Two spare RJ-45 connectors •  AC/DC power converter •  AirMux Manager installation CD •  Technical documentation CD •  ODU mounting kit •  External antenna (if ordered) 2.4 Installation and Setup Physical installation of the AirMux-200 system includes the following steps: 1. Installing management program on the network management station. ¨  Selecting IP address, subnet mask, default gateway and trap destination.
AirMux-200 Installation and Operation Manual Chapter   2  Installation and Setup  Installation and Setup 2-3 2. Installing Outdoor Unit (ODU) and Indoor Unit (IDU) at the local and remote sites. 3. Installing ODU cable and connecting ODU and IDU at the local and remote sites. 4. Aligning local and remote ODUs. 5. Connecting user equipment to the local and remote IDUs. 6. Connecting power. Figure   2-1 illustrates a typical installation of AirMux-200 with external antenna. Circuit Breaker16AODUCoaxial RFCableExternal Antenna220 VACAC/DC ConverterIDU-48 VDCMux/PBXHub/RouterEthernetE1RT Cable (100m max)(Ethernet, E1, -48 VDC)IndoorOutdoor Figure   2-1.  Typical Installation Diagram
Chapter   2  Installation and Setup  AirMux-200 Installation and Operation Manual 2-4 Installation and Setup  Installing AirMux-200 Management Software AirMux-200 management application is distributed on CD-ROM as an executable file. The application operates on a PC under any Windows 98/2000/NT/XP operating system. ä  To install the AirMux-200 management program: 1. Insert the CD-ROM into your CD-ROM drive. 2. Run Airmux.exe from the CD-ROM drive. 3. Follow the onscreen instructions of the installation wizard to complete setup of the AirMux-200 management program in the desired location. Connecting the ODU to the IDU The ODU cable conducts all the user traffic between the IDU and the ODU. The ODU cable also provides -48 VDC supply to the ODU. The maximum length for one leg of the ODU cable is 100m (328 ft). The ODU cable is supplied assembled with RJ-45 connectors, at the length specified when ordering. Spare RJ-45 connectors are supplied for use if necessary. 1. Route the cable from the ODU location into the building, leaving some spare. Secure the cable along its path. 2. Connect the ODU cable to the RJ-45 connector on the IDU rear panel designated WAN. Figure   2-2 illustrates a typical panel of the IDU.  Figure   2-2.  IDU Rear Panel Mounting and Aligning the ODU The ODU is the transmitting and receiving element of the AirMux-200 system. The ODU can be mounted on a mast or a wall. In both installations, the supplied mounting kit is used to secure the ODU. Appendix B describes the mast/wall installation instructions.
AirMux-200 Installation and Operation Manual Chapter   2  Installation and Setup  Installation and Setup 2-5 An AirMux-200 link operates in pairs of two AirMux-200 systems with the same configuration. Both systems must be installed, and the antennas of the outdoor units must be aligned for maximum throughput. You can verify that the AirMux-200 ODU units are aligned using a DVM-tool or the Buzzer located inside the ODU. Alternatively, this can be done via the AirMux management software.  Prior to connecting cables to the ODU, the protective earth terminal (screw) of the ODU must be connected to an external protective ground conductor or to a grounded mast. Only a qualified person using the proper safety equipment should climb the antenna mast. Only trained professional installers should be used when installing or dismantling ODUs and masts.  ä  To install the ODU: 1. Verify that the ODU mounting brackets are properly grounded. 2. Attach the ODU unit to the mast, using the two strap clamps. Refer to Appendix B for the ODU mounting instructions. 3. Connect the ground cable to the chassis point on the ODU. 4. Attach the ODU cable to the RJ-45 connector. Refer to Appendix A for the connector pinout. 5. Secure the cables to the mast or brackets using provided UV-rated cable ties. 6. Repeat the procedure at the remote site.  Do not tightly secure the ODU to its mounting brackets, if the alignment process of the antenna is not yet complete. When installing the ODU, it is important to check that there are no direct obstructions in front of the ODU or interference from man-made obstacles.  ä  To align the ODUs via ODU Buzzer: 1. Connect power to the IDUs. Warning Note
Chapter   2  Installation and Setup  AirMux-200 Installation and Operation Manual 2-6 Installation and Setup   Do not stand in front of a live radio terminal.  2. Turn the local ODU in the direction of the remote ODU. 3. At the remote site, turn the ODU to face the local ODU. (Align visually or by using a map and a compass). Use the DVM-tool or Buzzer indication on the ODU to verify link quality (see Figure   2-3). 4. Repeat step 3 for the local ODU to complete the installation procedure. 5. Slowly adjust the ODU at both sites until you hear the Best Signal sound. Buzzer Sequence   =buzzer on  =buzzer off Description  Radio is on but no radio link to the remote side  Best Signal so far  Signal better than the last second   Signal same as the last second  Signal worse than the last second Figure   2-3.  Buzzer Sequence for ODU Alignment Warning
AirMux-200 Installation and Operation Manual Chapter   2  Installation and Setup  Installation and Setup 2-7 ä  To align the ODUs using the AirMux Manager: 1. Connect power to the IDUs.  Do not stand in front of a live radio terminal.  2. Turn the local ODU in the direction of the remote ODU. 3. At the remote site, turn the ODU to face the local ODU. (Align visually or by using a map and a compass). 4. Repeat step 3 for the local ODU to complete the installation procedure. 5. Make sure that the management station is properly connected to the same LAN as the IDU, and the AirMux Manager application is running. 6. In the Main menu, click Monitor. Once the wireless link is established between the local and remote units, the Link Status indication bar in the middle of the Main menu turns green. In addition, Radio Link - Sync message appears in the logger at the bottom of the Main menu. 7. Check the radio signal strength (RSS) and sound-to-noise ratio (SNR) in the Main menu. Rotate the local ODU until the best RSS is found (better than -88 dBm). The SNR should be at least 9 dB. Monitor these parameters for about 15 minutes to verify stability.  Try to achieve the best possible RSS and SNR values.  8. After achieving the best RSS and SNR levels, permanently attach the ODU to the mast. Refer to Appendix B for the ODU mounting instructions. Connecting the User Equipment The IDU is a standalone desktop, wall-mounted or rack-installed unit. Figure   2-2 illustrates a typical rear panel of the IDU. ä  To connect user equipment to the IDU: 1. Connect a user mux or PBX to the IDU rear panel RJ-45 port designated Trunk. Refer to Appendix A for the connector pinout. Note Warning
Chapter   2  Installation and Setup  AirMux-200 Installation and Operation Manual 2-8 Installation and Setup  2. Connect user hub/router or any other compatible device to the IDU rear panel RJ-45 port designated LAN. Refer to Appendix A for the connector pinout.   Use a straight cable for router connection.  Connecting the Power  Before connecting any cable, the protective earth terminals of the AC/DC adapter must be connected to the protective ground conductor of the mains power cord. If you are using an extension cord (power cable) make sure it is grounded as well. Any interruption of the protective (grounding) conductor (inside or outside the instrument) or disconnecting of the protective earth terminal can make this unit dangerous. Intentional interruption is prohibited.  Power is supplied to AirMux-200 via an external AC/DC converter, which receives power from 100–240 VAC source and converts it to -48 VDC. ä  To connect the power: 1. Connect the 2-pin plug of the AC/DC converter to the 2-pin DC power connector on the IDU rear panel. 2. Connect the AC/DC converter 3-prong plug to the mains outlet. The unit turns on automatically upon connection to the mains.  Note Warning
 Performing Configuration of AirMux-200 3-1 Chapter   3 Configuration This chapter describes configuration procedures, which is performed after the physical installation of the local and remote AirMux-200 units. 3.1 Performing Configuration of AirMux-200 After physical installation of the local and remote AirMux-200 units, perform initial configuration of the system. ä  To perform initial setup: 1. Power up the local IDU (see Connecting the Power in Chapter 2). Wait for about 1 minute. 2. Power up the remote IDU. 3. Connect the management station to the LAN. Any PC running the AirMux-200 management application can be used to configure AirMux-200 units. ä  To start AirMux manager: 1. From the Start menu, point to Programs, point to AirMux Manager, and then click AirMux Manager. The password/IP request dialog appears. 2. Enter IP + password – airmux. The AirMux Manager Main menu is displayed (see Figure   3-1).  The system is factory installed with the settings of the system ordered, therefore the Install Link button is disabled.  Note
Chapter   3  Configuration AirMux-200 Installation and Operation Manual 3-2 Performing Configuration of AirMux-200   Figure   3-1.  AirMux Manager Main Menu
AirMux-200 Installation and Operation Manual Chapter   3  Configuration  Performing Configuration of AirMux-200 3-3 Configuring General Parameters In order to establish a link between the manager station and AirMux-200 you must configure the link channel and rate parameters. ä  To change general parameters: 1. In the Main menu, click Configure Link. 2. The Configuration Wizard opens. The wizard is used to install a link or make configuration changes.  When the SSID or Channel fields are changed, the link is reset. All changes made in the wizard are reflected in the Link Quality monitor pane.  3. Click Next. 4. The General Parameters dialog box appears (see Figure   3-2).  Figure   3-2.  General Parameters Dialog Box 5. From the General Parameters dialog box, enter data to describe the link: Note
Chapter   3  Configuration AirMux-200 Installation and Operation Manual 3-4 Performing Configuration of AirMux-200  § SSID – System ID. This number is initially factory set. It can be user defined, but both local and remote sites must have the same number. § Link name – enter a name for the link identification. § Site 1 – enter location name of site 1 § Site 2 – enter location name of site 2 6. Click Next. The Channel Select dialog box appears (see Figure   3-3) 7. Select the required operating channel. Table   3-1 lists channels and frequencies for ISM and UNII bands.  Figure   3-3.  Channel select Dialog Box  Table   3-1.  AirMux-200 Channels and Frequencies Channel ISM Band UNII Band 1 5740 MHz 5740 MHz 2 5760 MHz 5760 MHz 3 5780 MHz 5780 MHz 4 5800 MHz 5800 MHz
AirMux-200 Installation and Operation Manual Chapter   3  Configuration  Performing Configuration of AirMux-200 3-5 5 5820 MHz – 6 5840 MHz – Manual User defined channel, within frequency band 8. Click Next. The Rate Select dialog box appears (see Figure   3-4) Table 1-1 lists throughput rates and capacities.   Figure   3-4.  Rate select Dialog Box 9. Click Next. The Service Parameters dialog box appears (see Figure   3-5 and Figure   3-6). Configuring Service Parameters In the Service Parameters dialog box configure E1/T1 (x1 or x2) and Ethernet parameters. ä  To configure E1/T1 and Ethernet: 1. In the Service dialog box, select one of the following:
Chapter   3  Configuration AirMux-200 Installation and Operation Manual 3-6 Performing Configuration of AirMux-200  § E1/T1 – Select the E1/T1 field, if you intend to transmit E1/T1 data and Ethernet data (see Figure   3-5). The Ethernet BW field shows the remaining bandwidth in Mbps available for Ethernet. The available bandwidth depends on the number of E1/T1 ports selected. § Select the Ethernet field, if you intend to transmit Ethernet data only  (see Figure   3-6) 2. Click Next. The Finish screen appears (see Figure   3-7). The Finish screen shows a summary of the link configuration. 3. Click Finish to complete the configuration wizard.    Figure   3-5.  Service Parameters Dialog Box, E1 Interface Inventory
AirMux-200 Installation and Operation Manual Chapter   3  Configuration  Performing Configuration of AirMux-200 3-7  Figure   3-6.  Service Parameters Dialog Box, Ethernet only Interface  Figure   3-7.  Configuration Wizard Finish Screen Inventory
 Front Panel Indicators 4-1 Chapter   4 Operation This chapter provides the following information for AirMux-200: •  AirMux-200 front panel indicators  •  Operating procedures (turn-on, front panel indications, performance monitoring and turn-off) •  Procedures for changing AirMux-200 configuration parameters. 4.1 Front Panel Indicators The front panel of AirMux-200 includes a series of LED indicators that show the current operating status of the unit. Figure   4-1 shows the front panel of the AirMux-200 unit. Table   4-1 describes the AirMux-IDU indicators. AirMux-IDUSERVICEAIR I/FRTCBRTPWR Figure   4-1.  Front Panel Table   4-1.  IDU LEDs Name Function Location SERVICE (green/red)  ON (green) – E1 or T1 line is synchronized ON (red) – Alarm is detected at the E1 or T1 interface Front panel  AIR I/F (red) ON (green) – Wireless link is synchronized ON (red) – Wireless link lost synchronization Front panel  RTCB (green) ON – IDU self-test was completed successfully Front panel RT (green/red)  ON (green) – ODU-to-IDU communication link is operating properly ON (red) – ODU-to-IDU communication link is disrupted  Front panel PWR (green) ON – A power supply is ON Front panel
Chapter   4  Operation  AirMux-200 Installation and Operation Manual 4-2 Operating AirMux-200  LINK (green) ON – Good Ethernet link integrity Rear panel LAN connector ACT (yellow) Blinks according to the Ethernet traffic Rear panel LAN connector 4.2 Operating AirMux-200 Turning On AirMux-200 ä  To turn on AirMux-200: •  Connect the AC/DC converter to the IDU power connector and to the mains. The PWR indicator lights up and remains lit as long as the IDU is receiving power. AirMux-200 requires no operator attention once installed, with the exception of occasional monitoring of front panel indicators and statistics data. Intervention is only required when AirMux-200 must be configured to its operational requirements, or diagnostic tests are performed. Normal Indications Upon turning on AirMux-200, the PWR LED in the IDU front panel lights to indicate that AirMux-200 is on. Table   4-2 shows the correct status of the indicators a few seconds after power-up. Table   4-2.  AirMux-200 Indicator Status Indicator Status PWR ON RTCB Green – Blinking slowly RT Green – Blinking slowly Air Green – Blinking slowly Service Green – Blinking slowly
AirMux-200 Installation and Operation Manual Chapter   4  Operation  Operating AirMux-200 4-3 If the above LED indications do not appear following initial power turn-on, refer to Chapter 5 for the diagnostic test instructions.  During normal operation, the PWR led stays ON, all other LEDs blink at a four second cycle.  Turning Off AirMux-200  ä  To turn off AirMux-200: •  Remove the AC/DC converter power cord from the mains. Note
Chapter   4  Operation  AirMux-200 Installation and Operation Manual 4-4 Managing AirMux-200  4.3 Managing AirMux-200 Before starting a management session, make sure that a communication link between local and remote units exists. The Link Status indication bar in the middle of the Main menu must be green, the Radio Link - Sync message appears in the event log (see Figure   4-2).  Figure   4-2.  Main Menu, Wireless Link is Active The AirMux Manager Main menu consists of the following elements: •  Toolbar – includes buttons serving for: § Monitoring wireless (radio) link (Monitor button) § Changing configuration parameters of operating wireless link, assigning text files for storing alarms, statistics and configuration data (Configure Link button) § Performing preliminary configuration of the system (Install Link button). This button is disabled once a link is defined. § Clearing error counters (Clear Counters button) Menu Bar Toolbar Site A details Site B details Event Log Link QualityFrames Link TDM Service details Traffic Rate
AirMux-200 Installation and Operation Manual Chapter   4  Operation  Managing AirMux-200 4-5 § Logging off AirMux Manager (Log Off button) § Exiting AirMux Manager (Exit button) •  Menu bar – functions are similar to those of the toolbar. •  Link Parameters – summarizes information on the radio frequency, IP bandwidth, type of TDM service, number of assigned E1 or T1 timeslots, and IP details of the local and remote AirMux-200 units. •  Local and Remote Statistics – monitor traffic between local and remote devices and collect following statistics: § Local/remote received traffic rate (in kbps) § Local/remote received frames rate (in fps) § Radio link status § E1 or T1 link status § Radio signal strength (RSS) in dBm § Signal-to-noise ratio (SNR) in dB § Bit error rate. •  Event log – stores alarms generated by local and remote units.  ä  To change link configuration parameters: 1. In the Main menu, click Configure Link. The Configure Link wizard appears (see Figure   4-3). See Chapter 3 for configuration details. 2. Click Next. 3. In the General Parameters dialog box enter a new link name, locations of the local and remote ODUs. 4. Click Next. 5. Continue through the configuration wizard and define the Channel, Rate and Services of the link. 6. Once you finish changing configuration parameters, click Finish. Both AirMux-200 units are reset automatically (initially the remote unit, then the local one).
Chapter   4  Operation  AirMux-200 Installation and Operation Manual 4-6 Managing AirMux-200   Figure   4-3.  Configure Link Dialog Box Resetting AirMux-200  In order to maintain the communication link, always reset remote AirMux-200 first.  ä  To reset AirMux-200: 1. Click on maintenance select a local or remote AirMux-200 to reset. Saving AirMux-200 Configuration in a File AirMux-200 management software allows you to save configuration parameters of the local and remote units on the management station as an INI file. ä  To save configuration in a file: 1. From the Configuration menu (see Figure   4-3), click Backup. 2. In the Save As dialog box, indicate in which folder and under what name configuration file is to be saved, and click Save. Note
AirMux-200 Installation and Operation Manual Chapter   4  Operation  Managing AirMux-200 4-7 Uploading Configuration File Configuration files (*.ini) can be uploaded from the management station, if the AirMux-200 database becomes corrupted. This can also be used to distribute verified configuration files to all other units that use the similar configuration. ä  To upload configuration file to AirMux-200: 1. From the Configuration menu, select Configure Local ODU. The Configure Local ODU menu appears 2. From the Configure Local ODU menu, click Restore. 3. From the Open dialog, select *.ini file to upload and click OK. 4. From the Select ODU by Location menu, select the ODU to which the configuration file will be downloaded (local or remote). AirMux Manager displays confirmation message asking your approval to perform the download and restart the ODU. 5. Click Yes to approve. The configuration file is downloaded to the ODU and devices are reset.  Displaying the AirMux-200 Inventory The AirMux-200 inventory includes information on the hardware, firmware and software versions of the local and remote units. ä  To display inventory: •  In the Configuration dialog box, click the Inventory tab. The local and remote inventory information is displayed (see Figure   4-4).
Chapter   4  Operation  AirMux-200 Installation and Operation Manual 4-8 Managing AirMux-200   Figure   4-4.  AirMux-200 Inventory
 Error Detection 5-1 Chapter   5 Diagnostics and Troubleshooting This chapter describes the AirMux-200 diagnostic functions, which include: •  Status indications, alarms, power-up self-test •  Statistics collection •  Diagnostic tests (local and remote loopbacks on E1 or T1 link). 5.1 Error Detection Power-Up Self-Test AirMux-200 performs a hardware test of the IDU upon turn-on. This self-test checks the critical circuit functions of the unit. The RTCB LED indicates results of the self-test (see Chapter 4 for LED descriptions). Alarms AirMux-200 detects fault conditions of the radio and user links and initiates alarms to alert the user. The user can save the alarm log as a TXT file. Alarms are displayed in the Event Log (see Figure   5-1). The event log includes the following fields: •  Alarm sequential number •  Date and time stamp •  Message •  Alarm source (local or remote ODU) •  IP address of the ODU that initiated alarm.
Chapter   5  Diagnostics and Troubleshooting  AirMux-200 Installation and Operation Manual 5-2 Error Detection  Table   5-1.  AirMux-200 Alarms and Information Messages Message Description Radio Link – Sync Radio link is synchronized Radio Link – Out Of Sync Radio link lost synchronization Link Has Been Reset ODU was reset due to internal problem TDM Interface – Normal TDM interface is operating properly TDM Interface – LOS Loss of Synchronization is reported by TDM interface Table   5-1.  AirMux-200 Alarms and Information Messages (Cont.) Message Description TDM Interface – LOF Loss of Frame alignment is reported by TDM interface TDM Interface – AIS Alarm Indication Signal is reported by TDM interface TDM Interface – RAI Remote Alarm Indication is reported by TDM interface  TDM Interface – CRC CRC error was detected at TDM interface TDM Interface – CRC_E_BIT CRC E-Bit error was detected at TDM interface TDM Interface – Loopback A loopback is active on TDM interface Failed to download data to the remote ODU  AirMux-200 failed to download configuration data to the remote ODU Failed to download data to the local ODU  AirMux-200 failed to download configuration data to the local ODU Link Resetting Wireless link reset from the management station. This alarm is caused by automatic reset after link configuration. Local ODU Resetting The local ODU reset from the management station. Error loading trap catcher AirMux Manager detected that the SNMP port 162 of the management station has been previously captured by another application and cannot receive traps.  Monitor was stopped since no connection to the link  No ODU-to-IDU traffic was detected during the last 20 minutes.
AirMux-200 Installation and Operation Manual Chapter   5  Diagnostics and Troubleshooting  Error Detection 5-3  Figure   5-1.  AirMux-200 Alarms and Status Indications Saving Event Log The event log can be saved as a TXT file. New alarms are automatically added to the text file, as they enter the event log. ä  To save alarm log: 1. From the Tools menu, choose Preferences. The Preferences dialog box appears. 2. From the Preferences dialog box, select Event Log tab (see Figure   5-2). 3. Click the   button and in the Select File dialog box indicate in which folder and under what name the alarm log file is to be saved, and click Save.
Chapter   5  Diagnostics and Troubleshooting  AirMux-200 Installation and Operation Manual 5-4 Collecting Statistics   Figure   5-2.  Preferences Dialog Box, Event Log Tab 5.2 Collecting Statistics AirMux-200 constantly monitors traffic over the radio link and collects the following statistics data: •  Local/remote received traffic rate (in kbps) •  Local/remote received frames rate (in fps) •  Radio signal strength (in dBm) •  Signal-to-noise ratio (in dB) •  Bit error rate. Statistics log can also be saved as a text file. ä  To save statistics log: 1. From the Tools menu, choose Preferences. The Preferences dialog box appears. 2. From the Preferences dialog box, select Monitor tab (see Figure   5-3). 3. Click the   button and in the Select File dialog box indicate in which folder and under what name the statistics log file is to be saved, and click Save.
AirMux-200 Installation and Operation Manual Chapter   5  Diagnostics and Troubleshooting  Running Diagnostic Loopbacks 5-5 4. In the Interval box, type or select statistics refresh interval (in seconds).  Figure   5-3.  Preferences Dialog Box, Monitor Tab 5.3 Running Diagnostic Loopbacks AirMux-200 supports activation of the internal and external loopbacks on the local and remote units. ä  To activate a loopback: 1. From the Maintenance menu, choose Set Loopbacks. The Loopbacks dialog box appears (see Figure   5-4). 2. From the Local or Remote drop-down box, select a loopback that you intend to run, and click OK. A confirmation message appears. 3. Click Yes to activate a loopback. AirMux-200 activates selected loopback. A loopback status arrow in the Main menu turns green to indicate an active loopback.  ä  To deactivate a loopback: •  From the From the Local or Remote drop-down box of the Loopbacks dialog box, select N/A and confirm your choice.
Chapter   5  Diagnostics and Troubleshooting  AirMux-200 Installation and Operation Manual 5-6 Running Diagnostic Loopbacks  A loopback is deactivated and the corresponding status arrow in the Main menu becomes dimmed.  Figure   5-4.  Loopbacks Dialog Box Local External Loopback Local AirMux-200 can be set to an external loopback to test the local E1/T1 port and its connection to the local side user equipment. In this mode, data coming from the local user equipment is looped back to it (see Figure   5-5). This loopback is initiated from a management station connected to the local unit. Testing Equipment Management StationE1/T1 InterfaceLocal RT Figure   5-5.  Local External Loopback Remote Internal Loopback Remote AirMux-200 can be set to an internal loopback to test connection between the local and remote units, the local E1/T1 port and its connection to the local side user equipment. In this mode, data coming from the local AirMux-200 is looped back to it (see Figure   5-
AirMux-200 Installation and Operation Manual Chapter   5  Diagnostics and Troubleshooting  Running Diagnostic Loopbacks 5-7 6). This loopback is initiated from a management station connected to the local unit. Management StationE1/T1Interface E1/T1InterfaceTesting EquipmentRemote RTLocal RT Figure   5-6.  Remote Internal Loopback Remote External Loopback Remote AirMux-200 can be set to an external loopback to test the remote E1/T1 port and its connection to the remote side user equipment. In this mode, data coming from the remote user equipment is looped back to it (see Figure   5-7). This loopback is initiated by an inband command sent from a management station connected to the local unit. Testing Equipment Management StationE1/T1 Interface E1/T1 InterfaceLocal RTInband LoopbackActivation CommandRemote RT Figure   5-7.  Remote External Loopback
Chapter   5  Diagnostics and Troubleshooting  AirMux-200 Installation and Operation Manual 5-8 Troubleshooting  Local Internal Loopback Local AirMux-200 can be set to close an internal loopback to test connection between the local and remote units, remote E1/T1 port and its connection to the remote side user equipment. In this mode, data coming from the remote user equipment is looped back to it (see Figure   5-8). This loopback is initiated by an inband command sent from a management station connected to the local unit. Testing Equipment Management StationE1/T1 Interface E1/T1 InterfaceLocal RTInband LoopbackActivation CommandRemote RT Figure   5-8.  Local Internal Loopback 5.4 Troubleshooting The AirMux-200 LEDs show faults in the system or the link. Use Table  5-2 to diagnose the fault. Table   5-2.  Troubleshooting with AirMux-200 LEDs LED status Action PWR LED is off Check that AC adapter is connected to the IDU and the AC power outlet RTCB LED is yellow Check that the IDU/ODU cable is properly wired and connected RT LED is red Check that the IDU/ODU cable is properly wired and connected Air LED is yellow Complete the installation procedure from the
AirMux-200 Installation and Operation Manual Chapter   5  Diagnostics and Troubleshooting  Troubleshooting 5-9 management software Air LED is RED Check the ODU Antenna alignment. Check that the radio configuration of both local and remote units are the same (channel and SSID) Service LED is off Check the TDM service configuration in the NMS Service LED is yellow Check that the system is not in loopback mode. Check the remote IDU ports and cables and remote external equipment. Service LED is red Check the local IDU ports, cables and external equipment
Chapter   5  Diagnostics and Troubleshooting  AirMux-200 Installation and Operation Manual 5-10 Troubleshooting
 ODU-IDU Cable A-1 Appendix  A Wiring Specifications A.1  ODU-IDU Cable  The ODU-IDU cable is standard CAT-5, 4 twisted-pair 24 AWG FTP. The ODU-IDU cable is terminated in RJ-45 connectors on both ends. It is covered by a cable gland on the ODU side for hermetic sealing. Table  A-1 shows the connector pinout. Table  A-1.  ODU-IDU Cable Connector Pinout  IDU RJ45 Wire Color ODU RJ45 Function 1 White/Green 1 Twisted 2 Green 2 3 White/Orange 3 Twisted 6 Orange 6 Ethernet 4 Blue 4 Twisted  5 White\Blue 5 7 White/Brown 7 8 Brown 8 Twisted    Power
Appendix A   Wiring Specifications  AirMux-200 Installation and Operation Manual A-2 User Port Connectors  A.2  User Port Connectors The IDU includes ports for connecting E1/T1 and Fast Ethernet user devices. E1/T1 Port E1/T1 interface terminates in an 8-pin RJ-45 balanced connector, wired in accordance to Table  A-2. Table  A-2.  E1/T1 Connector Pinout Pin  Function 4,5 Receive (input) 1,2 Transmit (output) Fast Ethernet Port Fast Ethernet interface terminates in an 8-pin RJ-45 connector, wired in accordance to Table  A-3. Table  A-3.  Fast Ethernet Connector Pinout Pin Signal Function 1 TD (+) Transmit Data (positive) 2 TD (-) Transmit Data (negative) 3 RD (+) Receive Data (positive) 6 RD (-) Receive Data (negative)
 Mounting the ODU B-1 Appendix  B Mast and Wall Installation B.1 Mounting the ODU The ODU can be mounted on masts and walls. ODU Mounting Kit Contents The ODU mounting kit includes the following items: •   One Large Clamp (see figure B-1) •  One Small Clamp (see figure B-2) •  One Arm (see figure B-3) •  Four Screw hex head M8x40 •  Two Screw hex head M8x70 •  Four Washer flat M8 •  Three Washer spring M8 •  Two M8 Nuts   Figure  B-1.  Large Clamp Figure  B-2.  Small Clamp
Appendix  B  Mast and Wall Installation  AirMux-200 Installation and Operation Manual B-2 Mounting the ODU  Figure  B-3.  Arm
AirMux-200 Installation and Operation Manual Appendix B  Mast and Wall Installation  Mounting the ODU B-3 Mounting AirMux-200 on a Mast
Appendix  B  Mast and Wall Installation  AirMux-200 Installation and Operation Manual B-4 Mounting the ODU
AirMux-200 Installation and Operation Manual Appendix B  Mast and Wall Installation  Mounting the ODU B-5 Mounting AirMux-200 on a Wall
Appendix  B  Mast and Wall Installation  AirMux-200 Installation and Operation Manual B-6 Mounting Optional External Antenna  B.2 Mounting Optional External Antenna The optional external antenna can be mounted on masts. External Antenna Mounting Kit Contents The external antenna mounting kit includes the following items: •  Twelve flat washers •  Eight spring washers •  Eight hex nuts •  Four bolts •  One U-bracket •  One pivoting bracket  •  Two metal strap clamps.  ä  To install external antenna on the mast: 1. Attach the U-bracket to the back of the antenna using four flat washers, four spring washers and four hex nuts. 2. Attach the pivoting bracket to the U-bracket using eight flat washers, four spring washers, four hex nuts and four bolts. 3. Pass both strap clamps through the vertical slots in the pivoting bracket. 4. Attach the antenna to the mast using the two strap clamps. 5. Adjust the required tilt using the angular scale and tighten all bolts and nuts at the required position.
24 Raoul Wallenberg St., Tel Aviv 69719, IsraelTel: +972-3-6458181, Fax: +972-3-6483331, +972-3-6498250E-mail:                            , Web site:   Customer Response Form  RAD Data Communications would like your help in improving its product documentation. Please complete and return this form by mail or by fax or send us an e-mail with your comments.  Thank you for your assistance!  Manual Name:  _____________________________________________________________   Publication Number: ________________________________________________________    Please grade the manual according to the following factors:   Excellent Good Fair Poor Very Poor Installation instructions  r r r r r Operating instructions  r r r r r Manual organization  r r r r r Illustrations  r r r r r The manual as a whole  r r r r r   What did you like about the manual? ___________________________________________________________________________  ___________________________________________________________________________  erika_y@rad.cowww.rad.com AirMux-200   xxx-200-05/04
___________________________________________________________________________  ___________________________________________________________________________  ___________________________________________________________________________
Error Report Type of Error(s)   r Incompatibility with product or Problem(s):   r Difficulty in understanding text    r Regulatory information (Safety, Compliance, Warnings, etc.)    r Difficulty in finding needed information    r Missing information    r Illogical flow of information    r Style (spelling, grammar, references, etc.)    r Appearance    r Other _________  Please list the exact page numbers with the error(s), detail the errors you found (information missing, unclear or inadequately explained, etc.) and attach the page to your fax, if necessary. _________________________________________________________________________________________  _________________________________________________________________________________________  _________________________________________________________________________________________  _________________________________________________________________________________________   Please add any comments or suggestions you may have. _________________________________________________________________________________________  _________________________________________________________________________________________  _________________________________________________________________________________________   You are:   r Distributor    r End user    r VAR    r Other ________________________ Who is your distributor? _______________________________ Your name and company: _______________________________________________________
Job title: ________________________________________________________________________ Address: ________________________________________________________________________ Direct telephone number and extension: _________________________________________ Fax number: ____________________________________________________________________ E-mail: ___________________________________________________________________
 900 Corporate Drive, Mahwah, N.J. 07430, Tel: (201) 529-1100 24 Raoul Wallenberg Street, Tel Aviv 69719, Israel, Tel: 972-3-6458181 U.S. HEADQUARTERS: INTERNATIONAL HEADQUARTERS: Publication No. xxx-200-05/04 www.rad.com Fax: 972-3-6498250, 972-3-6474436, Email: rad@rad.com Toll Free: 1-800-444-7234, Fax: (201) 529-5777, Email: market@radusa.com