Raritan Engineering Seaera Toilets Users Manual L318

SeaEra Toilets L318seaerav0103

SeaEra Toilets to the manual 6d90a1b1-5c5a-4f81-a03d-69a30a5ca4ed

2015-02-06

: Raritan-Engineering Raritan-Engineering-Seaera-Toilets-Users-Manual-502323 raritan-engineering-seaera-toilets-users-manual-502323 raritan-engineering pdf

Open the PDF directly: View PDF PDF.
Page Count: 16

DownloadRaritan-Engineering Raritan-Engineering-Seaera-Toilets-Users-Manual- L318  Raritan-engineering-seaera-toilets-users-manual
Open PDF In BrowserView PDF
SeaEra Toilet
OPERATION, MAINTENANCE AND INSTALLATION INSTRUCTIONS
THE FOLLOWING ARE CAUTIONARY STATEMENTS THAT MUST BE READ AND
FOLLOWED DURING BOTH INSTALLATION AND OPERATION.
WARNING:

Raritan Engineering Company, Inc. recommends that a qualified person or electrician install this
product. Equipment damage, injury to personnel or death could result from improper installation.
Raritan Engineering Company, Inc. accepts no responsibility or liability for damage to equipment,
injury or death to personnel that may result from improper installation or operation of this product.

WARNING:

HAZARD OF SHOCK OR FIRE
Always use recommended fuse, circuit breaker and wire size.
Motors used with this product are “Ignition Protected”. They are not however, explosionproof as defined in 46CFR 110.15-65(e), Subchapter J-Electrical Engineering.
DO NOT run continuously for more than 30 seconds.

WARNING:

HAZARD OF FLOODING - Always shut off seacock(s) before leaving the boat unattended.
Double clamp all below waterline hose fittings and check frequently for integrity.

Pressurized
Freshwater Model

Sea Water Model
(Remote Pump)

Sea Water Model
(Integral Pump)

The SeaEra toilet is a powerful centrifugal macerating toilet that thoroughly breaks down waste.

1-800-352-5630
www.raritaneng. com

OPERATION

Press push-button switch and hold until all
waste is cleared from the toilet bowl.

•
•
•

•

No special toilet paper is required.
Water should appear in the bowl within ten
seconds. If not, see troubleshooting section.
Hard objects or stringy substances (paper
towels, feminine hygiene products, filter
cigarettes, etc.) must not be thrown into the
toilet as they will cause damage.
Always shut off seacock(s) before leaving the
boat unattended.

Young children should NOT be left unsupervised
around toilet. Serious injury or death could occur.
WARNING: DO NOT place hands in toilet
bowl without disconnecting
power. A sharp blade is used for
maceration of waste.
We offer an optional “child safety switch” which is
designed to make it difficult for young children to
operate toilet without adult supervision. For more
information, contact Raritan Technical Support
(1-800-352-5630).
WARNING: Children can drown in water
retained in the bowl.
CAUTION:
Seat and/or lid could close and
strike child.

2

IMPORTANT: Do not use cleaners that contain
ammonia, ethyl acetate, phosphoric acid or
concentrated chlorine bleach. These may cause
damage to the toilet.
Using C.P. a bio-enzymatic toilet bowl cleaner
(available from Raritan Engineering) will keep the
bowl clean and fresh smelling.

C.
P.

Recommend Visual Inspection
✔ For leaks at toilet and hose connections
✔
✔
✔
✔
✔

Hose clamps
Condition of hoses
Seacocks
Condition of wires and connections
In-Line Strainer (if you have one)

Cleaning In-Line Strainer
(Sea Water Models only)
1. Shut off intake seacock.
2. Unscrew bowl.

Filter

Clean Gasket
and Gasket
Contact Surfaces
Thoroughly

3. Remove filter.
4. Clean bowl and filter with a clean cloth.
5. Clean gasket and gasket contact surfaces
thoroughly.

Bowl
Unscrew

6. Replace gasket, filter and bowl.
7. Open seacock.
8. Check for leaks.

3

Tighten

MAINTENANCE

Cleaning Instructions

WINTERIZING

IMPORTANT
• Improper winter lay up is a major cause of
marine toilet failure.
• Use only nontoxic antifreeze.
• Flush toilet several times to clear waste
from system.
• Dispose of all antifreeze in accordance with
local and federal regulations.
• Winterize holding tanks, plumbing,
treatment systems (MSD’s), etc.
independently following manufacturer’s
instructions.
Pressurized Freshwater Models

Pressurized Freshwater Model

Parts Required
• 1" (25mm) or 1 1/2" (38mm) I.D.discharge
hose, approximately 3 feet (1m) long
• Two buckets
• Nontoxic antifreeze approximately 1 quart
(1 liter)
Steps
1. Close discharge seacock.
2. Shut off intake water at source.
3. Turn off power to unit.
4. Disconnect and drain discharge hose.
5. Disconnect intake hoses from vacuum breaker
and place in one of the buckets.
6. Connect hose to toilet’s discharge and place
in other bucket.
7. Pour antifreeze in bowl.
8. Turn on power to unit and flush until antifreeze
is removed from the bowl and water is drained
from the solenoid and hose.
9. Disconnect power to toilet.
10. Reconnect intake hoses to vacuum breaker.

4

Nontoxic
Antifreeze

Parts Required
3/4" (19mm) I.D. intake hose approximately 3 feet
(1m) long.
1" (25mm) or 1 1/2" (38mm) I.D. discharge hose
approximately 3 feet (1m) long.
Two buckets
Nontoxic antifreeze approximately 1 quart (1 liter)
Steps
1. Close the intake and discharge seacocks.
2. Turn off power to unit.
3. Disconnect and drain intake hose, discharge hose
and In-Line Strainer.
4. Connect short hoses to toilet’s intake and
discharge.
5. Place one bucket under hose connected to toilet’s
discharge.
6. Pour nontoxic antifreeze in other bucket.
7. Place hose connected to intake pump into bucket
with antifreeze.
8. Turn on power to unit and flush toilet until
antifreeze begins to be discharged from toilet.
9. Disconnect power to toilet.

Sea Water Model (Integral Pump)
Nontoxic
Antifreeze

Sea Water Model (Remote Pump)
Nontoxic
Antifreeze

RECOMMISSIONING
1. Using the buckets, hoses and approximately one
gallon (3.8 liters) of clean fresh water, flush
antifreeze out of the toilet (see Winterizing).
Dispose of antifreeze in accordance with local
and federal regulations.
2. Reconnect the intake and discharge hoses and
open both seacocks and water source valve.
3. Check all connections for leaks with several test
flushes.
SYSTEM START-UP
1. Open seacock(s).
NOTE: Pressurized freshwater models; open water
source valve.
2. Turn on power to toilet.
3. Flush toilet per Operation Instructions.
4. Check for leaks.
IMPORTANT: If toilet does not flush properly
or if water does not enter the bowl within 10
seconds, refer to Troubleshooting.
5

WINTERIZING

Integral and Remote Intake Pump Models

Integral Sea Water Model

SPECIFICATIONS

Pressurized Freshwater or Remote Sea Water Model

14 3/8" (36.5cm) Household
13" (33cm) Marine

19 3/4" (52.1cm) Household
17 1/2" (44.5cm) Marine

19 3/4"(50.2cm) Household
16 3/4"(42.6cm) Marine

14 7/8"
(37.8cm)
Household
14 1/2"
(36.8cm)
Marine

14 7/8"
(37.8cm)
Household
14 1/2"
(36.8cm)
Marine

13 3/8" (34cm)

6 5/8" (16.8cm)
11 1/8" (28.3cm)

Plumbing
Maximum suction of Intake pump
(Maximum height above waterline)

4 Ft. (1.2m) from Intake Pump.

CONVERSIONS

Maximum height of discharge vented loop

6 Ft. (1.8m) from base of toilet.

Wire - AWG to mm2

Pressurized water source requirements

minimum flow rate of 3 gpm (11.3 liters).
minimum pressure of 5 psi (34.5 kPa).

A WG

16

14

12

10

8

6

4

2

mm2

1.5

2.5

4.0

6.0

10.0

16.0

25.0

35.0

NOTES: for Wiring
Feet to Meters

1.

Distances are from source to unit and back to source.

2.

Distance from power source to remote intake pump MUST be included when
determining total distance.Same wire size MUST be used for lower base and
remote intake pump.

3.

Recommended conductor wire minimum AWG (mm2) for 3% voltage drop.

4.

Recommended conductor sizes are based on 105oC rated insulation.
Refer to ABYC Standards for other insulation ratings.

5.

For 120/240 VAC units use 24VDC specifications from transformer to unit.

Feet

10

15

20

25

30

40

50

Met er

3.1

4.6

6.1

7.6

9.2

12.2

15.2

Sea Water Model - Recommended Wire and Fuse/Circuit Breaker Size
In t eg r al Pu m p
an d l o w er b as e

Rem o t e Pu m p
an d l o w er b as e

A m p . d r aw
@ n o m i n al
v o l t ag e

A m p . d r aw
@ n o m i n al
v o l t ag e

Rem o t e Pu m p
only

Un i t s
Vo l t ag e

Ci r c u i t
B r eak er /f u s e
s i ze (am p s )

12 VDC

25

18

23

10

10 AWG 8 AWG

6 AWG

6 AWG

4 AWG

24 VDC

15

10

12.5

5

14 AWG 14 AWG

12 AWG

10 AWG

10 AWG

32 VDC

15

7.5

9

4

14 AWG 14 AWG

14 AWG

12 AWG

12 AWG

A m p . d r aw
@ n o m i n al
v o l t ag e

15
feet

20
feet

30
feet

40
feet

50
feet

Pressurized Freshwater Model - Recommended Wire and Fuse/Circuit Breaker Size
Un i t s
Vo l t ag e

Ci r c u i t
B r eak er /f u s e
s i ze (am p s )

A m p . d r aw
@ n o m i n al
v o l t ag e

12 VDC
L o w er B as e

25

13

24 VDC
L o w er B as e

15

7.5

32 VDC
L o w er B as e

15

5

12, 24, an d 32 VDC
Wat er So l en o i d
Val v e

3

2

10 feet

15 feet

20 feet

30 feet

40 feet

50 feet

12 AWG

10 AWG

10 AWG

8 AWG

6 AWG

6 AWG

14 AWG

12 AWG

10 AWG

10 AWG

8 AWG

6 AWG

16 AWG

16 AWG

14 AWG

12 AWG

10 AWG

10 AWG

16 AWG

16 AWG

16 AWG

16 AWG

16 AWG

16 AWG

6

Additional Parts Required
• Four stainless steel mounting bolts or lag
screws (minimum 1/4" [6mm]) and washers
• 1" (25mm) or 1 1/2" (38mm) I.D. discharge hose
• 3/4" (19mm) I.D. reinforced intake hose
• 3/4" (19mm) and 1" (25mm) or 1 1/2" (38mm)
hose clamps (two for each connection below
waterline)
• Wire
• Terminals
• Fuse/circuit breaker

All Complete Toilets
Toilet Bowl
Seat and Cover
Lower Base Assembly
Motor Cover
Push Button Switch
Sea Water Model
3/4" Hose Barb - straight fitting (2)
3/4" Hose Barb - 90° fitting
Plug Fitting
In-Line Strainer with fittings
3/4" Stainless Steel Hose Clamps (2)
Pressurized Freshwater Models
Atmospheric Vacuum Breaker (PLAVB0-5)
Solenoid Valve with fittings
Solenoid Valve Mounting Bracket
Tools Required
• 5/16" nut driver
• Wrench or screw driver
• 5/8" (16mm) drill bit
• Bit for drilling mounting surface
• Wire cutters
• Wire terminal crimpers
• Hose cutters
• Tape measure

Mounting Toilet
Mounting surface must be flat and solid.
1. Install seat on toilet.
2. Remove motor cover.
3. Place toilet where it will be located.
Make sure there is room to route hoses.
Make sure seat will open properly.
4. Mark location of toilet base mounting holes
on mounting surface.
5. Drill holes for toilet mounting bolts/screws.
NOTE: Hole size will depend on type of bolt/
screws used (5/16" [8mm] size bolts/screws are
recommended).
6. Secure toilet to surface.
7

INSTALLATION

Parts Included

INSTALLATION

90° Rotation of Toilet Bowl
Toilet bowl can be rotated 90° on the base, for
installing in confined locations.
NOTE: SeaEra Models with Integral Pump:
Replace existing hose from the intake pump to the
toilet bowl with a longer hose.
1. Determine which direction bowl is to be
mounted.
2. Remove hose at back of toilet (Sea Water
Model with Integral Pumps ONLY).
3. Remove four vinyl caps at the base of toilet
bowl.
4. Remove four nuts and shoulder washers.
5. Carefully remove toilet bowl from base.
6. Rotate toilet bowl to desired position.
7. Replace four shoulder washers, nuts and vinyl
caps.
NOTE: Tighten nuts carefully and evenly. Do
Not over tighten.

•
•
•
1.
2.
3.
4.
5.

Mounting Push Button Switch
Mount Push Button Switch in an accessible
location.
Make certain wires can be routed to Push
Button Switch.
Wire terminals must have clearance when
installed.
Drill 5/8" (16mm) hole.
Attach wires to Push Button Switch terminals
(see wiring section).
Install Push Button Switch through back of
mounting surface.
Install waterproof nut on Push Button Switch.
Secure in place with inner nut.

Install the Warning Label (L322) where it can
be easily seen.

8

1/4" Minimum clearance from terminals to any object

Inner Nut

From
Pressurized
Freshwater
Source
PLA7

IN
OUT

Mounting Atmospheric Vacuum Breaker
(Pressurized Freshwater Model only)

To inlet port of
vacuum breaker

Min. 6”
(15.3 cm)

1. Install fittings as shown.
2. Locate mounting area that is a minimum of 6"
(15.3cm) above toilet.
3. Secure where top is in horizontal position.
Mounting In-Line Strainer
(Seawater Models Only)
Make sure strainer bowl is tight.
1. Locate strainer where it will be accessible.
2. Mark and drill mounting holes.
NOTE: Hole size will depend on type of bolts/screws
used (1/4" [6mm] size bolts/screws are
recommended).
3. Install fittings provided (PLA7) on strainer’s inlet
and outlet ports.
NOTE: Use thread sealant.
4. Mount strainer. Hoses must be installed according
to flow marking on strainer top.

Flow Marking

Mounting Remote Intake Pump
(Remote Pump Models Only)
1. Remote intake pump must be mounted on a
flat solid surface in an area that is dry and well
ventilated.
2. Mark and drill mounting holes.
NOTE: Hole size will depend on type of bolts/screws
used. (1/4" [6mm] size bolts/screws are
recommended).
3. Mount pump. Do not over tighten bolts.
9

INSTALLATION

Mounting Water Solenoid Valve
(Pressurized Freshwater Models Only)
1. Locate valve on a solid flat surface in an area
that is dry and well ventilated.
2. Mark and drill holes for water solenoid mounting
bracket.
NOTE: Hole size will depend on type of bolts/screws
used (1/4" [6mm] size bolt/screws are recommended).
3. Mount bracket.
4. Install fittings provided (PLA7) on valve’s inlet
and outlet ports.
5. Attach valve to bracket. hoses must be installed
according to flow markings on valve body.

INSTALLATION

Pressurized Freshwater Model
Installed Above Waterline

PLUMBING
WARNING: Hazard of Flooding
Toilets mounted at or below the waterline
must have a vented loop installed in the
discharge line. The top of the vented loop
must be a minimum of 4" (10cm) above
the waterline at the boats greatest angle
of heel (see vented loop manufacturer’s
instructions).

Water
Solenoid
Valve
Waterline

Waterline
Discharge
Shut off
Valve

Sea Water Models must also have a vented
loop installed between the intake pump
and the toilet bowl.

Sea Water Model with Integral Pump
Installed Below Waterline

IMPORTANT

•

•

•

•
•

Fittings and 90° bends should be kept
to a minimum.
In-Line Strainer must be installed on
Sea Water Models per Installation
Instructions. Failure to do so may void
Warranty.
Discharging untreated sewage is
forbidden in all U. S. waters within the
three-mile limit.
Thru-hull fittings and seacocks must
be installed where they are easily
accessible.
Use only quality reinforced hoses.
Secure all hoses properly.

Holding Tank

Pressurized Freshwater
Source

Double clamp all below waterline
connections.

•

Vacuum
Breaker

SeaEra
Toilet

Discharge
Vented
Loop

Intake Vented
Loop
SeaEra
Toilet

Waterline

Lectra/San

Waterline

In-Line
Strainer

Discharge
Seacock

Intake
Seacock

Remote Intake Pump Model
Mounted Above Waterline
SeaEra Toilet

Remote
Intake
Pump

Discharge
Vented
Loop
Holding Tank

Waterline

Waterline
In-Line
Strainer

Intake
Seacock

Discharge Lines
1. Connect quality sanitation hose 1"
(25mm) or 1 1/2" (38mm) I.D. to
discharge fitting on toilet.
2. Run hose to appropriate device (i.e.:
treatment system, holding tank, etc.).

Y Valve

Lectra/San

Discharge
Seacock

1" (25mm)
Discharge Fitting
1 1/2" (38mm)
Discharge Fitting
10

Hose

From Pressurized
Freshwater Source
(Shut Off Valve)

IN
OUT

3. Connect hose from outlet port of vacuum breaker
to bowl elbow.

To Inlet Port
of Vacuum
Breaker

Outlet Port
Inlet Port

NOTE: Vacuum breaker must be last mechanical
component before bowl elbow.
Outlet Port
Arrow

Sea Water Models
Intake pump fittings are interchangeable to allow
more flexibility during installation. Inlet ports are
located on either side of intake pump. Outlet port
(to toilet bowl) is at top of intake pump.
1. Slide fitting clips to open position.
2. Select inlet port to be used.
3. Install appropriate fittings into inlet and outlet
ports.
NOTE: The 90° fitting can be rotated 360°.
4. Install the plug fitting into unused inlet port.

Inlet Ports

Closed
Open

IMPORTANT: Be sure not to install plug fitting
into outlet port! Damage will occur!

To Bowl

5. Slide fitting clips back to closed position.
6. Connect hose from seacock to inlet port of
In-Line Strainer. Use hose clamp provided.
7. Connect hose from outlet port of In-Line
Strainer to inlet port of intake pump. Use hose
clamp provided.
IMPORTANT: Double clamp all below
waterline hose connections!
8. Remote Pump Models Only: Connect hose
from outlet port of intake pump to bowl elbow
located on back of toilet bowl. (Integral pump
model is already connected).

From Strainer

Plug

From
Seacock

11

To Intake
Pump

INSTALLATION

Intake Lines
Pressurized Freshwater Models
Install a shut off valve in intake line before water
solenoid valve.
1. Connect hose from shut off valve to inlet port
of water solenoid valve.
NOTE: To avoid malfunction of water solenoid due
to debris in water, installation of Freshwater
Strainer (190601) is recommended.
2. Connect hose from outlet port of water solenoid
valve to inlet port of vacuum breaker.

WIRING

WIRING

Pressurized Freshwater Wiring

WARNING: Hazard of Shock and Fire
• Always use proper wire, wire connectors
and fuse/circuit breaker. See Specification
Chart.
• Secure wire properly.
• Do not connect appliances to toilet circuit.
• Make sure power is off before proceeding.
• Use proper wire terminals for all wire
connections.
1. Determine proper wire size by measuring
distance from:
• Power Source to push-button to toilet
motor and back to power source.
• Remote pump units - also include distance
from power source for remote pump to
remote pump and back. Same wire must
be used for both lower base and remote
pump.
2. Select proper wire and fuse/circuit breaker size
from Specifications on Installation page.
3. Install fuse/circuit breaker in positive line at
source.
4. Connect positive wire from fuse/circuit
breaker to Push Button Switch.
5. Connect wire from Push Button Switch to
orange wire on motor(s).
NOTE: Pressurized Freshwater Models; connect
wire from Push Button Switch to orange wire on
motor and from Push Button Switch to one of the
wires on water solenoid valve. The water solenoid
valve is not polarity sensitive.

Push Button
Switch
3 Amp
Fuse

Orange
POS (+)

Solenoid
Valve

Black
NEG (-)

Fuse or
Circuit
Breaker
NEG POS

Remote Pump Wiring

Push Button
Switch

Black
NEG (-)

Orange
POS (+)

Fuse or
Circuit
Breaker
Black
NEG (-)

NEG

POS

Integral Pump Wiring

6. Connect wire from battery negative or power
source ground buss to black wire (negative)
on motor(s).

Push Button
Switch

NOTE: Pressurized Freshwater Models; connect
remaining wire from water solenoid valve to
battery negative or power source ground buss.

Fuse or
Circuit
Breaker
Orange
POS (+)

NEG

Black
NEG (-)

12

POS

WARNING:

HAZARD OF ELECTRIC SHOCK - Before beginning any work on the SeaEra, be sure that all
power to the unit has been turned off.
WARNING: HAZARD OF FLOODING - Make sure seacocks are in the CLOSED or OFF position before
working on toilet.
NOTE:
The following information reflects the most probable causes and solutions to problems although not
every possible cause and solution is provided.
Any questions regarding servicing or operation of the SeaEra should be directed to our Technical Support Department in
Millville, NJ or Ft. Lauderdale, FL. Please have model and serial number available before calling.
PROBLEM

POSSIBLE CAUSE

1. Poor pumpout, especially
solids.

1A. Clogged discharge line.
1B.
1C.
1D.
1E.

1A. Be sure discharge seacock is open. Clear line, remove
clog.
Plumbing restrictions, bends and ells. 1B. Replumb to eliminate bends and ells.
Clogged vents.
1C. Clean holding tank vent and vented loop vents
Mineral buildup in hoses and fittings. 1D. Clean or replace affected parts. Replace hose if needed.
Low voltage.
1E. Check voltage at toilet while toilet is running. If
less than nominal voltage of toilet (12, 24, or 32),
check condition of batteries and wire sizes. Check
terminals and wire connections for corrosion (heat at
terminals and junctions indicates a bad or corroded
connection).

2. Poor water flow, especially
at front of bowl (or no water flow).

2A. Toilet not level.
2B. Restriction in intake line.
2C. Pump sucking air.

3. Foul odors from toilet area.

2D.
2E.
3A.

3B.
3C.
4. Bowl fills while underway.

4A.

5. Water leaking from under
unit.

5A.
5B.
5C.
6A.
6B.
6C.

6. Erratic operation/sluggish
running.

SOLUTION

2A. Raise rear of toilet; check with level.
2B. Be sure seacock is open. Clear line-remove clog.
2C. Check all connections from intake thru-hull to intake
pump to be sure no air leaks are present.
Low voltage.
2D. See 1E, above.
Clogged strainer.
2E. Remove or Clear debris from strainer.
“Marine life” lodged in rim of bowl. 3A. Remove and flush bowl with pressure hose to remove
all material. Install strainer in intake line to avoid recurrence.
Permeated discharge hose.
3B. Replace hose with Raritan sanitation hose (#SH).
Sewage remaining in discharge line. 3C. Flush toilet longer; replace hose if permeated; reroute
hose making a shorter run if possible.
Pressure buildup at seacocks.
4A. Close intake, then discharge seacock to determine
which is causing problem. If discharge, be sure the
vent or vented loop is clean. If intake, there is too
much pressure on seacock; contact Raritan Technical
Support.
Leaking bowl gasket.
5A. Tighten (4) bowl mounting nuts (#1226B).
Leak at shaft seal.
5B. Check seal and motor shaft.
Leak from seal plate area.
5C. Check seal plate o-ring.
Worn motor brushes.
6A. Return motor to factory for servicing or replacement.
Motor bearings damaged by seal leak. 6B. Return motor to factory for servicing or replacement.
Low or inconsistent voltage.
6C. See 1E above.

Tip for Removing Intake Pump

Set screw must be loosened
with 1/8" hex key before
removing the intake pump
from motor
Plug

13

TROUBLESHOOTING

TROUBLESHOOTING

EXPLODED PARTS

SeaEra PARTS LIST
Part No.

Description

Part No.

1108A
1222AW
1226
1226B
1234
1236AW
1236E
1237
1244
1610*
161105
161107
161110
161115
161120
161123
161125
161130
162135
162225
162305
162310
162315
162320
162325A

Macerator Nut
90° Discharge Fitting
Mounting Screw (4)
1/4-20 Hex Nut (4)
Bowl Gasket
Bowl Spud Assembly
Bowl Elbow
Marine-size Bowl
Household-style Bowl
Motor
Base
Seal Plate O-Ring
Seal Plate
Impeller
Impeller/Macerator Housing
Macerator Blade
Discharge Mounting Flange
Discharge Fitting
Cone Seal
O-Ring
Lower Housing includes #162315
Diaphragm includes #162315
Piston (4)
Piston Seat (4) includes #162315
Bearing Plate Assembly includes
#162315
3/4" Hose Barb - 90° Fitting
3/4" Hose Barb - Straight Fitting (2)
Plug Fitting
Fitting Clip (3)
Fitting O-Ring (4)

162100W Upper Housing Assembly
162200W Middle Housing Assembly
162300W Lower Housing Assembly
163000
Inline Strainer
164000
Push Button Switch
31-102
Shaft Seal
41-260
Bowl Elbow (Freshwater Models Only)
C254
Joker Valve
CH38
1/4-20 Threaded Stud (4)
F005
Set Screw
F020
Piston Fastener (4)
F144
Mounting Bolt Washer (4)
F162VT
Mounting Bolt
F164
Discharge Mounting Flange Fastener(4)
HW1
Mounting Screw Lockwasher (4)
M23A
Macerator Lockwasher (5)
Additional Parts Included with
INTEGRAL MODELS
161140
Motor Cover Integral

162405
162410
162415
162420
162425

Description

Additional Parts Included with
REMOTE MODELS
161135
Motor Cover
1660*
Intake Motor
166000
Remote Intake Pump, 12V DC
166100
Remote Intake Pump, 24V DC
166200
Remote Intake Pump, 32V DC
Additional Parts Included with
FRESHWATER MODELS
161135
Motor Cover
PLAVB0-5 Atmospheric Vacuum Breaker
PLA5
1/2” MPT PVC Nipple
PLA6
1/2” FPT to 3/4” Barbed Elbow
PLA7
1/2” GC Solenoid Valve
CWPS*A 1/2” GC Solenoid Valve
CWPSMB Water Solenoid Valve Mounting Bracket
Repair Kits
DIAPUMPRK Diaphragm Pump Repair Kit
SEADISRK
SeaEra Discharge Repair Kit
* Specify DC Voltage (12, 24, 32)
14

1244 or 1237

SOLENOID VALVE
CWPS*A
PLA7

1236AW

VCAP

PLA7

1226B

CWPSMB

RNI

ATMOSPHERIC
VACUUM BREAKER
PLAVB0-5
PLA6
PLA5

1234
1236E

CH38

161135 or 161140
PLA7

161105
C254
161130
161107
1108A

161125

164000
161123

M23A

F164

HW1
1226

161120
31-102

1222AW

161115
161110

F005
1610*

1660*
162325A

163000
F020
162305

162320
162310
162300W

162410

162315

162420

162425

162225
162135
162415

162200W
162425

162420
190601 - Recommended for use with
Freshwater Solenoid (Not Included)

F144
M23A

162425

F162VT

162405
162100W

15

EXPLODED PARTS

SeaEra Exploded Parts View

LIMITED WARRANTY

1.

2.

3.

4.

5.

6.

Raritan Engineering Company warrants to the original purchaser that this product is free of defects
in materials or workmanship for a period of one year from the product’s date of purchase. Should
this product prove defective by reason of improper workmanship and/or materials within the
warranty period, Raritan shall, at its sole option, repair or replace the product.
TO OBTAIN WARRANTY SERVICE, Consumer must deliver the product prepaid, together with
a detailed description of the problem, to Raritan at 530 Orange St., Millville, N.J. 08332, or 3101 SW
2nd Ave. Ft. Lauderdale, FL 33315. When requesting warranty service, purchaser must present a
sales slip or other document which establishes proof of purchase. THE RETURN OF THE OWNER
REGISTRATION CARD IS NOT A CONDITION PRECEDENT OF WARRANTY COVERAGE.
However, please complete and return the owner Registration Card so that Raritan can contact you
should a question of safety arise which could affect you.
THIS WARRANTY DOES NOT COVER defects caused by modifications, alterations, repairs or
service of this product by anyone other than Raritan; defects in materials or workmanship supplied
by others in the process of installation of this product; defects caused by installation of this product
other than in accordance with the manufacturer’s recommended installation instructions or standard
industry procedures; physical abuse to, or misuse of, this product. This warranty also does not cover
damages to equipment caused by fire, flood, external water, excessive corrosion or Act of God.
ANY EXPRESS WARRANTY NOT PROVIDED HEREIN, AND ANY REMEDY FOR BREACH
OF CONTRACT WHICH BUT FOR THIS PROVISION MIGHT ARISE BY IMPLICATION OR
OPERATION OF LAW, IS HEREBY EXCLUDED AND DISCLAIMED. ALL IMPLIED
WARRANTIES SUCH AS THOSE OF MERCHANTABILITY AND OF FITNESS FOR A
PARTICULAR PURPOSE, IF APPLICABLE, AS WELL AS ANY IMPLIED WARRANTIES
WHICH MIGHT ARISE BY IMPLICATION OF LAW, ARE EXPRESSLY LIMITED TO A
TERM OF ONE YEAR. SOME STATES DO NOT ALLOW LIMITATIONS ON HOW LONG A
LIMITED WARRANTY LASTS, SO THE ABOVE LIMITATION MAY NOT APPLY TO YOU.
UNDER NO CIRCUMSTANCES SHALL RARITAN BE LIABLE TO PURCHASER OR ANY
OTHER PERSONS FOR ANY SPECIAL OR CONSEQUENTIAL DAMAGES, WHETHER
ARISING OUT OF BREACH OF WARRANTY, BREACH OF CONTRACT, OR OTHERWISE.
SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR
CONSEQUENTIAL DAMAGES, SO THE ABOVE LIMITATION OR EXCLUSION MAY NOT
APPLY TO YOU.
No other person or entity is authorized to make any express warranty, promise or affirmation of fact
or to assume any other liability on behalf of Raritan in connection with its products except as
specifically set forth in this warranty.
This warranty gives you specific legal rights, and you may also have other rights which vary from
state to state.

530 Orange Street, P.O. Box 1157, Millville, NJ 08332 USA
Telephone: 856-825-4900 FAX: 856-825-4409
www.raritaneng.com
Southern Office and Plant:
3101 SW Second Avenue, Fort Lauderdale, FL 33315 USA
Telephone: 954-525-0378 FAX: 954-764-4370
L318 0103kgs

Specifications Subject to Change Without Notice
16

Printed in U.S.A.



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.3
Linearized                      : Yes
Create Date                     : 2003:03:07 13:36:24-05:00
Modify Date                     : 2003:03:07 13:36:24-05:00
Subject                         : l318
Page Count                      : 16
Creation Date                   : 2003:03:07 18:36:24Z
Mod Date                        : 2003:03:07 18:36:24Z
Producer                        : Acrobat Distiller 5.0 (Windows)
Author                          : Sheila
Keywords                        : 
Metadata Date                   : 2003:03:07 18:36:24Z
Creator                         : Sheila
Title                           : l318
Description                     : l318
EXIF Metadata provided by EXIF.tools

Navigation menu