Rayence RY1417WGB Industrial Image Processing Unit User Manual

Rayence Co., Ltd. Industrial Image Processing Unit

User manual

Download: Rayence RY1417WGB Industrial Image Processing Unit User Manual
Mirror Download [FCC.gov]Rayence RY1417WGB Industrial Image Processing Unit User Manual
Document ID2231256
Application IDlNqhiA89sOD35EHOFlx+Mg==
Document DescriptionUser manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize156.69kB (1958646 bits)
Date Submitted2014-04-01 00:00:00
Date Available2014-09-28 00:00:00
Creation Date2014-01-24 15:22:45
Producing SoftwareMicrosoft® Office Word 2007
Document Lastmod2014-04-02 11:42:53
Document TitleUser manual
Document CreatorMicrosoft® Office Word 2007
Document Author: Kang-min_Hwang

Version 0
Date: 2014-01-02
1417WGB
User / Installation Manual
R-USM-503
© Copyright 2014, Rayence Co. Ltd.
All pages of this document contain proprietary and confidential
information of Rayence Corporation and are intended for exclusive use
by Rayence Corporation personnel or customers. Copying, disclosure to
others or other use is prohibited without the express written
authorization from Rayence Corporation. Please report any violations of
requirement to Rayence Corporation.
R-USM-503
Attention
For improvement of product performance, supplementation, or follow-up of information; the
contents of this manual are subject to change without separate prior notice.
Please note that our company has neither responsibility for any accidents nor obligation to
do free repair service for any damage of the equipment due to user's mistake, which resulted
from failure to follow the contents in this manual. Make sure to be familiar with the safety
precautions and usage procedures. Also note that the product may slightly differ from the
contents of this manual depending on specification.
The following marks are used for the effective use of the product in this manual.
Attention, consult accompanying documents.
This is used to emphasize essential information. Be sure to read this
information to avoid incorrect operation.
This indicates hazardous situation which, if not heeded, may result in
minor or moderate injury to you or others, or may result in machine
damage.
This indicates a potentially hazardous situation which, if not heeded, could
result in death or serious injury to you or others.
Federal Law restricts this device to sale by or the order of a radiologist or
any other practitioners licensed by the law of the state in which that
person practices to use or order the use of the device.
R-USM-503
Contents
1. Introduction......................................................................................5
(1)
(2)
(3)
(4)
(5)
(6)
Overview .......................................................................................... 5
Product features .............................................................................. 5
Product component ........................................................................ 6
Components Description ............................................................... 8
Warning .......................................................................................... 11
Caution ...........................................................................................13
2. Notes for Using the Detector ........................................................15
(1)
(2)
(3)
(4)
(5)
(6)
Handling .........................................................................................15
Handle Assembly ..........................................................................15
Before Exposure............................................................................16
During Exposure ...........................................................................16
Disinfection and Cleaning ............................................................16
Others .............................................................................................16
3. Technical Features ........................................................................17
(1)
(2)
(3)
(4)
Mechanical Features .....................................................................17
Electrical Features ........................................................................17
Environmental requirement .........................................................19
PC Requirements ..........................................................................20
4. Installation .....................................................................................21
(1)
(2)
(3)
(4)
(5)
(6)
Program setup ...............................................................................21
Connection (Manual Trigger) .......................................................22
Connection (Auto Trigger) ............................................................30
IP set up .........................................................................................34
Checking Connection ...................................................................34
Using Web Manager (IP, SSID Change / Upgrade FW) ..............35
5. Calibration ......................................................................................39
(1) General Principle ...........................................................................39
(2) Calibration ......................................................................................41
6. Image Acquisition Test..................................................................46
(1) Get Image .......................................................................................46
(2) View Images ...................................................................................47
7. Operation........................................................................................52
(1) Recommend ...................................................................................52
(2) Switching power on / off ...............................................................52
(3) Storage ...........................................................................................52
8. Radio Frequency compliance ........................................................53
(1) FCC Notice (U.S.A) ........................................................................53
(2) IC Notice (CANADA) ......................................................................55
(3) R&TTE Notice (European Union) .................................................56
9. Maintenance ..................................................................................57
(1)
(2)
(3)
(4)
Maintenance...................................................................................57
Cleaning .........................................................................................57
Inspection ......................................................................................58
Marking and labeling symbols .....................................................59
Appendix ..............................................................................................61
R-USM-503
1. Introduction
(1) Overview
The 1417WGB is a digital X-ray flat panel detector that can
generate images of NDT. This X-ray imaging system consists of
a scintillator directly coupled to an a-Si TFT sensor. It makes
high-resolution, high-sensitive digital images.
(2) Product features

Based on a-Si TFT active matrix

Compact (18mm thickness) and light weight

High resolution : Min. 2.5 lp/mm, Max 3.9 lp/mm

14-bit digital output

Easy integration
R-USM-503
(3) Product component

Photo
Industrial Image Processing Unit
Item
Part Name
Quantity
Detector
RD1417WGB
Handle
Battery pack
RB37WH
Battery charger
RC120W
Charger
adapter
PMP120-13-3
AGI
RA001A
RS1417
Power
box
supply
R-USM-503

Cable
Item
Part Name
Length Quantity
Link cable
VRH076A
6m
PInterface
cable
VRH017A
8m
USB
cable(A to VRH078A
B)
1.8m
LAN
cable
10m
1.8m
VRH027A
AC Power
VRH018A/019A
cord


Installation CD
Manual
Detector Library
Trigger cable
Option
R-USM-503
(4) Components Description
The detector is designed to capture radiographic images.
Captured images are transmitted to PC using the wired
connection.
(1) Detector
1. LED indicator: The LED indicates the state of detector.
i. Green: Power
ii. Blue: Link
iii. Orange: Low battery
2. Handle : Hold this handle when carrying the sensor unit. It is
removable. (Horizon)
3. Handle unlock-lever : This is an unlock-lever to remove handle.
4. Link cable connector : This is a connector for Wire communication.
Connect to provided link cable and another end of the cable
connects to the PC.
5.
CFRP(Carbon Fiber Reinforced Plastic) : The object to which an
image is to be taken should be placed against this plate..
R-USM-503
(2) Power supply
1. Power plug connector: Connect with AC power supply cord
2. LAN connector : Ethernet port for transmitting the image/command
between detector and PC
3. Link cable connector: Power connector for detector operating
4. LED indicator: Four LEDs to display the status
※ Changeable part: Fuse T3.15 AL 250V
(3) AGI

1. Trigger connector: This is a connector for synchronization
between detector and generator. Connect the AGI to the generator
using P-interface cable..
2. USB connector: This is a connector for communication between
AGI and PC. Connect the AGI to the PC using USB cable
R-USM-503
(4) Battery & Charger
1. Battery : Lithium ion battery. The number of times being acquired
image is 960 images(@ cycle time : 15s). The batteries last 2.5
hours and are rechargeable.
2. Charger : Two port cradle type.
3. LED indicator :
i. Orange on : charging
ii. Green on : Charging is completed.
10
R-USM-503
(5) Warning
Environment of Use and Storage
Follow the specified process of operational instructions written in
this manual for the safety of the users
Does not use or store the instrument near any flammable
chemicals such as thinner, benzene, etc. Also, this instrument is
Make sure
to observe
the following right
not a category AP or APG equipment. If chemicals are spilled or
evaporate, it may result in fire or electric shock through contact
with
electric
parts
inside
the
instruments.
Also,
some
disinfectants are flammable. Be sure to take care when using
them.
Connection
Do not connect the instrument with anything other than specified.
Otherwise, it may result in fire or electric shock.
To avoid the risk of electric shock, this equipment must only be
connected to a supply mains with protective earth.
Handling
Always be sure to keep checking the condition of the system to
ensure they are normal during the use of the instrument. If any
problem is found, take appropriate measures, such as stopping
the operation of the instrument, as required.
Never disassemble or modify the product as it may result in fire
or electric shock. Also, since the instrument incorporates parts
that may cause electric shocks and other hazardous parts,
touching them may cause death or serious injury.
Do not hit or drop the instrument. The instrument may be
damaged if it receives a strong jolt, which may result in fire or
electric shock if the instrument is used without it being repaired.
When Problem Occurs
11
R-USM-503
Should any of the following occur, immediately turn OFF the
power of each instruments, unplug the power supply cord from
the AC outlet, and contact Rayence representative or distributor.

When there is smoke, odd smell or abnormal sound.

When liquid has been spilled into the instrument or a metal
object has entered through an opening.

When the instrument has been dropped and it is damaged.
Maintenance and Inspection
For safety reasons, be sure to turn OFF the power of each
instrument when the inspections indicated in this manual are
Make sure
to observe
the following right.
going to be performed. Otherwise, it may result in electric shock.
When the instrument is going to be cleaned, be sure to turn OFF
the power of each instrument, and unplug the power supply cord
from the AC outlet. Never use benzene, thinner or any other
flammable cleaning agents. Otherwise, fire or electric shock may
result.
The instrument must be repaired by a qualified engineer only. If it
is not repaired properly, it may cause fire, electric shock, or
accident.
12
R-USM-503
(6) Caution
Environment of Use and Storage
Do not install the instrument in a location with the conditions
listed below. Otherwise, it may result in failure or malfunction, fall
or cause fire or injury.

Close to facilities where water is used.

Close to air-conditioner or ventilation equipment.

Close to heat source such as a heater.

Prone to vibration.

Insecure place.

Dusty environment.

Saline or sulfurous environment.

High temperature or humidity.

Freezing or condensation.
Do not place the storage case in a location with the conditions
listed below.

Where the cable of the sensor unit will be strongly pulled
when the sensor unit is put into the case, otherwise, the cable
may be damaged, resulting in fire or electric shock.

Where someone might get their foot caught in the cable of the
sensor unit is put in the case. Otherwise they could trip over,
resulting in injury
13
R-USM-503
Handling
Wipe the CFRP plate of the sensor unit with ethanol or
glutaraldehyde solution
Turn off the power of each instrument for safety when they are
not going to be used.
Maintenance and Inspection
For safety reasons, be sure to inspect the instrument before
using it. In addition, carry out a regular inspection at least once a
year.
If the device does not work, do not disassemble yourself. Please
contact to the Rayence C/S team.
14
R-USM-503
2. Notes for Using the Detector
(1) Handling
Handle the instrument carefully, as it may be damaged if
something is hit against it, dropped, or receives a strong jolt.
(2) Handle Assembly
Please confirm lever position. When the
handle is locked, the lever should be
same position with the right picture.
If the
handle is
not locked,
the detector can be
dropped.
Insert the handle in
the same direction
※ Insert the handle always in the same
15
R-USM-503
(3) Before Exposure
Be sure to check the equipment daily and confirm that it works
properly.
Sudden heating of the room in cold areas will cause
condensation to form on the instrument. In this case, wait until
condensation disappears before performing exposure.
If the instrument is used with condensation formed on it,
problems may occur in the quality of the instrument. When an airconditioner is going to be used, be sure to raise/lower the
temperature gradually so that a difference in temperature in the
room and in the instrument does not occur, to prevent forming of
condensation.
(4) During Exposure
Do not use the detector near devices generating a strong
magnetic field. Doing so may produce image noise or artifacts.
Do not apply excessive weight to the sensor unit. Otherwise, the
sensor may be damaged.
(5) Disinfection and Cleaning
Do not spray the detector directly with disinfectants or detergents.
Do not use anything other than neutral detergent for cleaning the
cover of the instrument. Otherwise, the coating will be corroded.
(6) Others
Be sure to reconnect the cables to the proper connectors.
Otherwise, the instrument may malfunction or may be damaged.
16
R-USM-503
3. Technical Features
(1) Mechanical Features
Size
475 x 399 x 18 mm
Weight
5.3 kg
Encapsulation Material
Mg
Window Material
Carbon fiber plate
(2) Electrical Features
Detector
Sensor Type
Amorphous Silicon with TFT (Single Panel)
X-ray Converter
Gd2O2S:Tb
Total Pixel Number
3328 × 2816 pixels
Total Pixel Area
422.7 x 357.6 mm
Effective Pixel Number
3268 × 2756 pixels
Effective Pixel Area
415.0 x 350.0 mm
Pixel Pitch
127 μm
Limiting Resolution
Max. 3.9 lp/mm
Energy Range
40 - 150 kV
A/D Conversion
14 bits
< 2.0 sec (wired)
Preview Time
< 5.0 sec (wireless)
Data Interface
Gigabit Ethernet
Wi-Fi (802.11a/b/g/n)
Table 1: Product specification

Under RQA5 condition (70kVp, 21mmAl)

Preview time is not included post-processing time
17
R-USM-503
Battery
Size
232.5 x 132.8 x 7 mm
Weight
Typ. 0.3 kg
Input
12.5 VDC
Output
11.1 VDC
Charging time
Typ. 2.5 hours
Capacity
Typ. 3400 mAh
The number of times
being acquired image
960 images (@cycle time = 15s)
The Battery level can be displayed on the LED status of battery.
If the battery level goes down under 25%, please charge the
battery
Battery level
Display
75~100 %
50~75 %
25~50 %
0~25 %
Charger
Size
267.5 x 100 x 77 mm
Weight
Typ. 0.86 kg
Input
20 VDC
Output
11.1 VDC
Adapter
Size
160 x 76 x 43.7mm (cable length: 1.28m)
Weight
Typ. 0.92 kg
Input
100~240 VAC, 47~63 Hz, 1.4~0.6A
Output
20 VDC, Max 6.0A
18
R-USM-503
Wireless Spec
802.11a/b/g/n compliance
Standard
Without DFS (5.25GH to 5.35GHz and 5.47
to 5.725) Band
Peak Rate
300Mbps
Frequency
2.4 GHz / 5 GHz
Bandwidth
20MHz/40MHz
MIMO
2x2
※ Recommended Maximum operable distance : 7m
(From the Access Point)
※ 5150~5250 MHz band is restricted to indoor operations
only. (for FCC)
5150~5250 MHz band is restricted to indoor operations
only. (for CE)
5150~5250 MHz is indoor use only. (for Japan)
(3) Environmental requirement
Item
Min
Temperature
Typ.
Max.
Unit
40
℃
Humidity
30
75
Pressure
70
106
Note
H.R.
kPa
10-150Hz,
Vibrations
2G
(Wrapping
(8G)
condition)
10Sweeps,
1min/Octa
ve, XYZ
axis
19
R-USM-503
(4) PC Requirements

Processor: At least Intel Pentium IV HT with 2.8GHz, Intel
Core Duo / Core 2 or comparable AMD Dual Core processor

At least 3GB of RAM requirement (4GB for 32 BITS OS and
8GB for 64 BITS OS recommended)

At least 500GB for application and archiving. Recommended
500GB for applications and secondary drive of 1TB for image
archiving..

Dual 10/100/1000 network card system required. One for
network (Internet) and one for the DR Panel communication

Graphics card / monitor: Resolution of at least 1,600 x 900 for
desktop and 1366 x 768 for laptop. For diagnostics purpose
we recommend 1920 x 1080 resolution (2 mega pixels)
monitor

Microsoft® Windows 7 32BIT/64BIT

No antivirus except for Microsoft® Security Essentials.
20
R-USM-503
4. Installation
The Detector is composed of sensitive electronic parts and
Portable
Imaging
processing
unit must be
installed in a way
that enables the
user to achieve
optimal use
components. It is recommended to use the product in a clean
place and to exercise caution to ensure that it is not affected by
dust or liquids. It is recommended to Use a dry and soft cloth to
clean the detector housing.
(1) Program setup
To acquire images, run _vadav.lnk program.
Please set the following figures

Detector’s IP : Wireless-192.168.1.80, Wired-192.168.1.81

Detector‘s number of ADC : 0

Detector’s size of image : 3328 x 2816
21
R-USM-503
(2) Connection (Manual Trigger)
Power Connection
A. Connect the battery pack or power cable to the equipment.
* In wired mode, the frame ground is necessary.
B. Connect the USB cable from your PC to AGI.
※ Be sure to sure only the dedicated battery pack, RB37WH
for 1417WGB.
22
R-USM-503
Wireless Communication
A. AP Router(Line sharer) setting
- SSID : Griffon
- Internal network
- IP address : 192.168.1.80
- Subnet mask : 255.255.255.0
- Dynamic IP allocation range : 192.168.1.2 ~
192.168.1.254
- Pre-Shared Key(Password) : project302
- Authentication methods : WPAPSK or WPA2PSK
- Password methods : TKIP/AES
- AP IP : 192.168.1.1
- Channel (Frequency)
- Avoid crowded channel
(Using wireless detector under crowded channel result
in low performance)
- If available, Use ‘Auto-Channel Selection’ function
of router to find optimal channel
B. Reception Indicator
Link LED flickering
Blink Speed : Slow – Low link quality
Fast – High link quality
23
R-USM-503
C. Checking Link Quality & Battery Remain
- After wireless connection is established, perform ‘Get Bright’
in ‘Calibration’ tap.
- Check the value named ‘Wireless Signal’ in black log screen.
Wireless Signal = Link Quality (Max. 100)
- Check the value named ‘Battery Remain’ in black log screen.
Battery Remain = Battery Remain(Max. 100)
The value ‘Wireless
Signal’ will be
displayed here
24
R-USM-503
Software Setting
25
R-USM-503
Trigger Connection
A. Connect the P-interface cable or trigger cable to the generator
X-ray Generator Connection
Make
assurance
doubly sure
SIGNAL RATING
before connection.
A. Mode 1 : P-interface cable mode
Connect the P-interface cable between the AGI box and X-ray
generator.
Operating description
26
R-USM-503
The window time can be changed. Refer to the following pictures
27
R-USM-503
B. Mode 2 : Trigger cable mode
Make
assurance
doubly sure
SIGNAL RATING
before connection.
Connect the Trigger cable between the X-ray enable connector of
AGI with X-ray generator.
AGI
Box
Figure 8: <2nd example> wiring for the interface between portable generator & detector
Connection description
Signal
New Label
Old Label
Color
Input / Output
12V~24VDC
R.E.C. +12-24V
Red
Input
READY IN
Ready Input Signal
Black
Input
READY DONE
Exposure Output SW1
Green
Output
READY DONE COM
Exposure Output SW2
Blue
Output
READY IN
READY
DONE
28
R-USM-503
Operating description
t1: It will be occurred when exposure switch is pushed completely
after.
t2: Window time of detector is varying 0 sec ~ 15 sec. which can
be control by S/W.
 Expose relay switch ON time (Window Time) and X-ray
exposure time must be same.
 t2 time can be control by S/W
The window time can be changed. Refer to the following pictures
29
R-USM-503
(3) Connection (Auto Trigger)
Power Connection
A. Connect the battery pack or power cable to the equipment.
* In wired mode, the frame ground is necessary.
※ Be sure to sure only the dedicated battery pack, RB37WH
for 1417WGB.
30
R-USM-503
Wireless Communication
A. AP Router(Line sharer) setting
- SSID : Griffon
- Internal network
- IP address : 192.168.1.80
- Subnet mask : 255.255.255.0
- Dynamic IP allocation range : 192.168.1.2 ~
192.168.1.254
- Pre-Shared Key(Password) : project302
- Authentication methods : WPAPSK or WPA2PSK
- Password methods : TKIP/AES
- AP IP : 192.168.1.1
- Channel (Frequency)
- Avoid crowded channel
(Using wireless detector under crowded channel result
in low performance)
- If available, Use ‘Auto-Channel Selection’ function
of router to find optimal channel
B. Reception Indicator
Link LED flickering
Blink Speed : Slow – Low link quality
Fast – High link quality
31
R-USM-503
C. Checking Link Quality & Battery Remain
- After wireless connection is established, perform ‘Get Bright’
in ‘Calibration’ tap.
- Check the value named ‘Wireless Signal’ in black log screen.
Wireless Signal = Link Quality (Max. 100)
- Check the value named ‘Battery Remain’ in black log screen.
Battery Remain = Battery Remain(Max. 100)
The value ‘Wireless
Signal’ will be
displayed here
32
R-USM-503
Software Setting
33
R-USM-503
(4) IP set up
[My Network Places] → [Properties] → [Local Area Connection]
→ [Properties] → [Internet Protocol (TCP/IP)]
→ [Use the following IP address]
IP address: Obtain an IP address automatically
IP address : Obtain an IP address automatically
(5) Checking Connection

Check LED on the detector & power supply

Ping test: [Start] →[Run] →ping -t 192.168.1.80
34
R-USM-503
(6) Using Web Manager (IP, SSID
Change / Upgrade FW)
Change IP Address of Detector
A. Turn on Detector and connect to PC
(wired connection is recommended)
B. After detector boot up, Launch web-browser
(Optimized for Chrome/Internet Explorer)
C. Connect to “http://[Detector’s IP]“
D. Select IP address to change from drop-down menu
35
R-USM-503
E. Click “SUBMIT”
F. Restart detector(Turn Off then On)
Change SSID and PSK(Pre-Shared Key)
A. Turn on Detector and connect to PC
(wired connection is recommended)
B. After detector boot up, Launch web-browser
(Optimized for Chrome/Internet Explorer)
C. Connect to “http://[Detector’s IP]“
D. Select SSID to set
(This value should match to Router’s setting)
36
R-USM-503
E. Type Pre-Shared Key to set (Password)
(This value should match to Router’s setting
Default:project302 )
F. Click “SUBMIT”
G. Restart detector(Turn Off then On)
Upgrade Firmware
A. Turn on Detector and connect to PC
(wired connection is recommended)
37
R-USM-503
B. After detector boot up, Launch web-browser
(Optimized for Chrome/Internet Explorer)
C. Connect to “http://[Detector’s IP]“
D. Select firmware file by click “Choose File” button.
(Released file is named ‘fw_ppc’)
E. Click ‘Upload File’ button
F. Click ‘Flash Write’ button
G. Restart detector(Turn Off then On)
38
R-USM-503
5. Calibration
X-ray
detector
should be
used at stable state
within driving
temperature range.
Acquire the X-ray
images after power
on and 30 minutes
warming up to
obtain high quality
images.
(1) General Principle
Notation
Calibration can be done by image acquisition S/W. The gainoffset correction (under calibration) will be done with one dark, at
least one bright and object frame.
Parameter
Description
Offset
Dark image, acquired image without X-ray exposure
Bright
Acquired image with X-ray exposure
Object
Bright image with object, will be calibrated
Gain
Gain of imaging system, offset subtracted image
Offset correction
Offset subtract
Gain correction
Compensate gain variance of pixel
Table 4: Parameter description
39
R-USM-503
Bright Calibration Point
The
calibration
range of
bright is can be
select by which
exposure level is
maximum level that
user want to use. If
the maximum level
of user want to use
is ‘6500’ in this case
the level is
contained in Bright
point of ‘3’(refer
‘Table 5 : Median
value’). The meaning
is you don’t have to
make bright point
for ‘4’(In this case, it
will be does not
working if you get
image on higher
level than maximum
bright point.)
To gain correction, bright frame and dark frame should be
acquired. The dark frame is needed only one frame. The bright
frame is recommended to be acquired more than 2 different
levels of median values of bright frames. The X-ray source
condition will be recommended the tube energy level of 70kVp
with variable tube current and exposure time. To acquire at least
2 frames at same condition will be recommended. The median
values of bright frames are below.
(Additional 21mm Al filter is recommended for calibration)
Point
Median Value [LSB
500 ~
1000
2900 ~
3400
6200~
6700
9500 ~
10000
Table 5 : Median value
The Purpose of Bright Calibration
The center of the non calibrated image is brighter than the edge
due to hill effect of X-ray exposure. Generally, the intensity of Xray flux at center region of exposed area is higher than
surroundings due to the X-ray expose like cone shape. A
calibration process is used to compensate for this effect.
Generally, called it ‘Flat Field Correction’ (Bright calibration).
Figure 8: Comparison of flat field correction processing
40
R-USM-503
(2) Calibration
Describe the calibration step by step.
1st Step
Click on the “Get Dark” button. The acquired dark frame
“dark.raw” will be generated in the “\cal\” folder.
Figure 9: Get dark
41
R-USM-503
Click
button [Get
Bright]. It
will produce frame
with name %CAL%
xNNNNNA.raw,
where NNNNN is
median pixel’s value
within current
image borders after
offset calibration
(cut frame edges are
never used during
calibration). Suffix
‘A’ (it also could be
‘B’,’C’ etc) avoids
casual coincidence
of file names.
2nd Step
Push “Get Bright” button at different four of X-ray condition. The
X-ray condition should be set or tested before, same as the level
of ‘1.2’. Push “Get Bright” button at least 2 times at same
condition, and then the offset subtracted bright (gain) is
generated which of filename is “xNNNNNA.raw(Refer to NOTE)
Figure 10: Get bright.
42
R-USM-503
3rd step
After 2nd step, the “Generate” button will be activated. Click the
button “Generate”, and then calibration point will be generated
which of file name is “A ‘# of point’_ ‘median value of generated
point’” like file of bright frame. The acquired bright frames within
tolerance value which is variance of median level of acquired
bright frames will be averaged and generated to a calibration
point. The tolerance value can be edited.
After making
calibration point the
“Generate” button will
be disabling.
Figure 11: Generate
43
R-USM-503
4th step
After 3rd step, Change Bad Pixels Removal Tab, Click the button
“Generate Auto BPM”, and then Defect Map will be generated
which of file name is “BPM.raw “ at the “\cal\” folder.
Figure 12: Bad pixels removal
44
R-USM-503
5th step
For additional Defect correction, if “BPMM.raw” is existed at the
install CD, copy to the “\cal\” folder.
6th step
On Acquisition Tab. Check the box “Offset Calibration”, “Gain
Calibration”, “Bad Pix Map” for activate to each calibration and
Bad Pixels Removal. Otherwise, it will does not working when
going to pre-processing .
Figure13: Application of calibration
45
R-USM-503
6. Image Acquisition Test
(1) Get Image
On Acquisition tab, click the “Get Image” button to get image.
After click the button, you can see pop-up window, which is
display window time and process of acquiring image.
Figure 14: Get image
46
R-USM-503
(2) View Images
Frame- and image-files have extension “raw” and contain pixel
data in signed 16-bits little-endian format. One could view those
files in Photoshop or another image editor.
Figure 15: View images
47
R-USM-503
Common controls and displayed statistics
Figure 16: Description of viewer 1

Pixel_Min – minimum pixel value in frame- or image- data

Pixel_Max – maximum pixel value

Pixel_Black – if a pixel ≤ Pixel_Black then it is displayed as
black (RGB 0, 0, 0)

Pixel_White – if a pixel ≥ Pixel_Black then it is displayed as
black (RGB 255, 255, 255)
48
R-USM-503
Histogram’s presentation
Relative Histogram Scale [H]=1000 means that that the distance
depicted as “H” on the drawing matches 1% of total number of
pixels. Respectively [H]=100 means that “H” matches 0.1% of
pixels and [H]=500 means that “H” matches 0.5% of pixels.
Figure 17: Description of histogram
49
R-USM-503
Marker type “S”
Displays local surround of selected location
Figure184: Description of marker type "S"
Marker type “R”
Display profile chart of a row.
Figure 19: Description of marker type "R"
50
R-USM-503
Marker type “C”
Display profile chart of a column.
Figure 20: Description of marker type "C"
51
R-USM-503
7. Operation
(1) Recommend
X-ray detector should be used at stable state within driving
temperature range.
Acquire the X-ray images after power on and 30 minutes
warming up to obtain high quality images.
The calibration should be performed every 6 months
(2) Switching power on / off

All connection should be done, before turn on the power.

Press the power button by more than 3 sec, when power
on/off.

The green light of the LED indicator on the detector is on, the
detector power is on.

The blue light of the LED indicator on the detector is blinking,
the detector is getting prepared to work and initialize.

After power off, separate the battery.
(3) Storage
Store the sensor unit in clean and dry place. Ensure that storage
place should be not affected by dust or liquids.
52
R-USM-503
8. Radio Frequency compliance
(1) FCC Notice (U.S.A)

Test standards
- 47CFR Part 15.107 (b) / 47CFR Part 15.109 (g) Class A.
- FCC Part 15 C Section 15.247
- FCC Part 15 C Section 15.407

FCC ID: QIIRY1417WGB
5.15- 5.25 GHz band is restricted to indoor operations only.
Compliance with FCC requirement 15.407(c)
Data transmission is always initiated by software, which is the passed
down through the MAC, through the digital and analog baseband, and
finally to the RF chip. Several special packets are initiated by the MAC.
These are the only ways the digital baseband portion will turn on the RF
transmitter, which it then turns off at the end of the packet. Therefore,
the transmitter will be on only while one of the aforementioned packets
is being transmitted. In other words, this device automatically
discontinues transmission in case of either absence of information to
transmit or operational failure.
This device complies with part 15 of the FCC Rules. Operation is
subject to the following two conditions: (1) This device may not cause
harmful interference, and (2) this device must accept any interference
received, including interference that may cause undesired operation.
53
R-USM-503
FCC CAUTION
Changes or modifications not expressly approved by the party
responsible for compliance could void the user’s authority to operate the
equipment. This transmitter must not be co-located or operated in
conjunction with any other antenna or transmitter.
When installing it in a mobile equipment
This equipment complies with FCC radiation exposure limits set forth for
an uncontrolled environment and meets the FCC radio frequency (RF)
Exposure Guidelines in Supplement C to OET65. This equipment has
very low levels of RF energy that it deemed to comply without maximum
permissive exposure evaluation (MPE). But it is desirable that it should
be installed and operated keeping the radiator at least 20cm or more
away from person’s body (excluding extremities: hands, wrists, feet and
ankles).
When you use the detector with wire mode, the wireless function is
automatically off.
54
R-USM-503
(2) IC Notice (CANADA)

Test standards
- ICES-003 Issue 4
- IC RSS-210 Issue 8

IC: 10742A-1417WGB
This Class A digital apparatus complies with Canadian ICES-003
This device complies with Industry Canada licence-exempt RSS
standard(s). Operation is subject to the following two conditions: (1) this
device may not cause interference, and (2) this device must accept any
interference, including interference that may cause undesired operation
of the device.
Le present appareil est conforme aux CNR d'Industrie Canada
applicables aux appareils radio exempts de licence. L'exploitation est
autorisee aux deux conditions suivantes : (1) l'appareil ne doit pas
produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout
brouillage radioelectrique subi, meme si le brouillage est susceptible
d'en compromettre le fonctionnement.
55
R-USM-503
(3) R&TTE Notice (European Union)

Test standards
- EN 62311
- ETSI EN 301 489-1
- ETSI EN 301 489-17
- ETSI EN 300 328
- ETSI EN 301 893
56
R-USM-503
9. Maintenance
(1) Maintenance
When the
instrument
is going to
be cleaned, be sure
to turn OFF the
power of each
instrument, and
unplug the power
cable from the AC
outlet. Never use
benzene, thinner or
any other
flammable cleaning
agents. Otherwise,
fire or electric shock
may result.

Maintenance of the detector should be done by an authorized
service provider

If the Detector Panel is defective, the detector will be
returned as is to the manufacturer for repair

Clean the equipment with a dry soft cloth, or a soft cloth
lightly moistened with mild detergent solution. Do not use any
type of solvent, such as benzene

This equipment and accessories are to be disposed of safely
after the life span of them and national regulation must be
observed.

For safety reasons, be sure to inspect the instrument before
using it. In addition, carry out a regular inspection at least
once a year.

Arrange the detector and power supply link cable to prevent
the damage of the cable’s rubber tube. For example, do not
press the cable under the legs of the table or the people.

If you need more information, please contact to the Rayence
C/S team, they will provide it.
(2) Cleaning
Cover
Clean the cover by the left warning box, if it is dirty.
CFRP of Detector
Wipe the CFRP plate of the sensor unit with ethanol or
glutaraldehyde solution. If you are using disinfectant other than
those specified above, or you are mixing another disinfectant with
57
R-USM-503
ethanol, please also consult a specialist, because they may harm
the CFRP plate.
For
safety
reasons, be
sure to turn OFF the
power of the
detector when the
following
inspections are
going to be
performed.
Otherwise, it may
result in electric
shock.
(3) Inspection
In order to ensure that the instrument is used safely and normally,
please be sure to inspect the instrument before use. If any
problem is found during the inspection, please take measures
indicated in this chapter. If problem still cannot be corrected,
please contact Rayence representative or distributor. It is
recommended that a record of the inspection be kept by making
copies of the check lists in this section, or making a separate
check list.
Inspection chart
Inspection
Check
that
User
cables
are
Vendor
Cycle
not
damaged or cover of cables is
Daily
Daily
Daily
Daily
not torn
Check that the plugs and locks
of connectors are not loose
Check that the cover or parts
are not damaged and not loose
Check the LED indicator
Check the bad pixel map
Half year
Yearly
Check the performance of the
instrument
by
performing
exposures using a phantom or a
resolution chart
58
R-USM-503
(4) Marking and labeling symbols
Symbols
Meaning
Caution : “Attention, see instructions for use”
Alternate current
Protective earth (Ground)
Off (power : disconnect from the main switch)
On (power : connect to the main switch)
Warning
Caution
Note
59
R-USM-503
Manufacturer
Date of manufacture
Serial number
WEEE
: Waste
Electrical
and
Electronic
Equipment
Figure 21: Labeling symbols
60
R-USM-503
Appendix
Dimension
[unit : mm]
61
R-USM-503
Rayence Co., Ltd.
14, Samsung 1-ro 1-gil, Hwaseong-si, Gyeonggi-do, Korea
www.rayence.com
Rayence Co., Ltd.
14, Samsung 1-ro 1-gil, Hwaseong-si, Gyeonggi-do, Korea
www.rayence.com
R-USM-503
62

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : No
Author                          : Kang-min_Hwang
Create Date                     : 2014:01:24 15:22:45+09:00
Modify Date                     : 2014:04:02 11:42:53+09:00
Has XFA                         : No
Language                        : ko-KR
XMP Toolkit                     : Adobe XMP Core 4.2.1-c041 52.342996, 2008/05/07-20:48:00
Format                          : application/pdf
Creator                         : Kang-min_Hwang
Creator Tool                    : Microsoft® Office Word 2007
Metadata Date                   : 2014:04:02 11:42:53+09:00
Producer                        : Microsoft® Office Word 2007
Document ID                     : uuid:12292118-4af1-462b-9426-ec80571b2449
Instance ID                     : uuid:601f0c76-27be-4a5f-a12a-13dadc58ba19
Page Count                      : 62
EXIF Metadata provided by EXIF.tools
FCC ID Filing: QIIRY1417WGB

Navigation menu