Rayson Technology BTM-22X Bluetooth Module User Manual BTM222 DataSheet
Rayson Technology Co., Ltd. Bluetooth Module BTM222 DataSheet
Manual
Rayson Bluetooth ® Module Class1 BC04-ext Module Features ■ Bluetooth Ver. 2.0+EDR certification ■ Transmit Power up to +18dBm(class1) ■ Low current consumption: Hold, Sniff, Park, Deep sleep mode ■ 3.0V to 3.6V operation ■ Full Bluetooth Data rate over UART and USB ■ Support up to 7 ACL links and 3 SCO links ■ Enhanced Data Rate(EDR) compliant for both 2Mbps and 3Mbps modulation modes ■ Interface: USB, UART&PCM( for voice codec) ■ SPP firmware with AT commands ■ RoHS Compliant ■ Small outline: 28.2 X 15.0 X 2.8 mm Application ● Access point ● Domestics and Industrial applications ● Serial Adapter ● GPS, POS, Barcode Reader Block Diagram BTM-222 Outline Electrical Characteristics Absolute Maximum Ratings Parameter Min. Storage Temperature -40 Supply Voltage(VDD) 2.7 Supply Voltage(PVCC) 3.0 Other Pin Voltage Vss-0.4 Recommended Operating Conditions Parameter Temperature Supply Voltage(VDD) Supply Voltage(PVCC) General Electrical Specification Parameter Carrier Frequency RF Output Power RX sensitivity Load Impedance Input Low Voltage Input High Voltage Output Low Voltage Output High Voltage Average Current Consumption Min. -20 3.0 3.0 Description Measured in 50ohm No abnormal Oscillation RESET,UART,GPIO,PCM RESET,UART,GPIO,PCM UART,GPIO,PCM UART,GPIO,PCM Receive DM1 Max. +85 3.7 3.6 VDD+0.4 Unit ℃ DCV DCV DCV Typ. +75 3.3 3.3 Unit ℃ DCV DCV Min. 2.402 15 Typ. -0.30 0.7VDD VDD-0.4 114 16.5 -88 Max. 2.480 18 -86 5:1 0.80 VDD+0.3 0.40 Unit GHz dBm dBm DCV DCV DCV DCV mA Radio Characteristics - Basic Data Rate Transmitter , VDD = 3.3V Temperature =+20°C Frequency (GHz) 2.402 RF transmit power 2.441 2.480 Initial carrier frequency tolerance 2.402 2.441 2.480 -20dB bandwidth for modulated 2.402 carrier 2.441 2.480 Carrier Frequency Drift (single 2.402 slot packet DH1) 2.441 2.480 Carrier Frequency Drift (five slot 2.402 packet DH5) 2.441 2.480 2.402 Drift Rate 2.441 2.480 Min. Typ. 16 16 16 17.5 17.5 17.5 12 10 890 870 820 ±10 ±10 ±10 ±10 ±10 ±10 ±7 ±7 ±7 Max. 18.5 18.5 18.5 25 25 25 1000 1000 1000 ±20 ±20 ±20 ±20 ±20 ±20 ±14 ±14 ±14 Bluetooth Specification -6 to +20 ±75 < 1000 <25 <40 <20 Unit dBm dBm dBm kHz kHz kHz kHz kHz kHz kHz kHz kHz kHz kHz kHz kHz/50µs kHz/50µs kHz/50µs RF power control range 2.402 △f1 “Maximum Modulation” 2.441 2.480 2.402 maz △f2 “Minimum Modulation” 2.441 2.480 Adjacent channel transmit power F=F0±2MHz Adjacent channel transmit power F=F0±3MHz avg Adjacent channel transmit power F>F0 +3MHz Adjacent channel transmit power F16 140<△f1avg <175 >115 < - 20 < - 40 < - 40 < - 40 dB kHz kHz kHz kHz kHz kHz dBm dBm dBm dBm Receiver , VDD = 3.3V Temperature =+20°C Frequency (GHz) 2.402 Sensitivity at 0.1% BER 2.441 (Single slot packets) 2.480 2.402 Sensitivity at 0.1% BER 2.441 (Multi slot packets) 2.480 Maximum received signal level at 2.402 0.1% BER 2.441 2.480 C/I co-channel Adjacent channel selectivity C/I F=F0 +1 MHz Adjacent channel selectivity C/I F=F0 - 1MHz Adjacent channel selectivity C/I F=F0 +2 MHz Adjacent channel selectivity C/I F=F0 - 2MHz Adjacent channel selectivity C/I F>=F0 +3 MHz Adjacent channel selectivity C/I F<=F0 -5 MHz Adjacent channel selectivity C/I F=Fimage Min. -20 -20 -20 F0 = 2441 MHz Maximum level of intermodulation interference (n=5) -88 -88 -88 -88 -88 -88 -10 -10 -10 -4 -4 -38 -23 -45 -44 -22 -86 -86 -86 -86 -86 -86 11 -30 Bluetooth Specification Unit < 11 <0 <0 < - 30 < - 20 < - 40 < - 40 <-9 dBm dBm dBm dBm dBm dBm dBm dBm dBm dB dB dB dB dB dB dB dB > -39 dBm < - 70 < - 70 > - 20 Radio Characteristics – Enhanced Data Rate Transmitter , VDD = 3.3V Temperature =+20°C Maximum RF transmit power (note) Frequency (GHz) 2.402 2.441 2.480 Relative transmit power π/4 DQPSK Maximum carrier frequency stability w0 π/4 DQPSK Maximum carrier frequency stability wi π/4 DQPSK Maximum carrier frequency stability | w0 + wi | Min. Typ. Max. Bluetooth Specification 16 16 17 -1.6 -4 to +1 < ±10 for all blocks dBm dBm dBm dB kHz < ±75 for all packets kHz < ±75 for all blocks kHz -6 to +20 Unit 8 DPSK Maximum carrier frequency stability w0 8 DPSK Maximum carrier frequency stability wi 8 DPSK Maximum carrier frequency stability | w0 + wi | π/4 DQPSK RMS DVEM Modulation Accuracy 99% DEVM Peak DEVM 8 DPSK RMS DVEM Modulation Accuracy 99% DEVM Peak DEVM F>F0 +3 MHz In-band spurious emissions F 99 Receiver , VDD = 3.3V Temperature =+20°C Sensitivity at 0.1% BER Modulation Min. Typ. π/4 DQPSK -87 -78 -8 -10 10 19 -10 -5 -11 -5 -40 -40 -23 -20 -45 -45 -45 -45 8 DPSK Maximum received signal level at π/4 DQPSK 0.1% BER 8 DPSK π/4 DQPSK C/I co-channel at 0.1% BER 8 DPSK Adjacent channel selectivity C/I π/4 DQPSK F=F0 +1 MHz 8 DPSK Adjacent channel selectivity C/I π/4 DQPSK F=F0 -1 MHz 8 DPSK Adjacent channel selectivity C/I π/4 DQPSK F=F0 +2 MHz 8 DPSK Adjacent channel selectivity C/I π/4 DQPSK F=F0 -2 MHz 8 DPSK Adjacent channel selectivity C/I π/4 DQPSK F=F0 +3 MHz 8 DPSK Adjacent channel selectivity C/I π/4 DQPSK F=F0 -5 MHz 8 DPSK F0 = 2405, 2441, 2477 MHz Adjacent channel selectivity C/I π/4 DQPSK F=Fimage 8 DPSK -20 -15 Max. Bluetooth Specification < -70 < -70 > -20 > -20 < +13 < +21 <0 < +5 <0 < +5 < -30 < -25 < -20 < -13 < -40 < -33 < -40 < -33 Unit dBm dBm dBm dBm dB dB dB dB dB dB dB dB dB dB dB dB dB dB < -7 <0 dB dB Note : Measurement made using a POWER_TABLE entery of TX_PRE 80, INT PA63, EXT PA255. This ensures that the Bluetooth requirements for ACP and those defined by the FCC and ETSI are satisfied over the operating temperature rang of -5℃ ℃to +45℃ ℃. Although the design is capable of generating in excess of +18dBm, regulatory compliance over the full temperature range of -5℃ ℃ to +45℃ ℃ will not be satisfied if the transmit power approaches this value. Application Schematic XC6209 U2 E3 ANTENNA VOUT NC VIN CE GND 3.3V C70 2.2uF C73 2.2uF L8 ANTENNA matching circuit INDUCTOR C71 CAP NP C72 CAP NP TX RX TO Host 3.3V C74 0.1u RESET SPIMISO SPIMOSI SPICSB SPICLK UART_CTS UART_TX UART_RTS UART_RX AIO0 AIO1 3V3 GND GND BTM-222 L7 GND +V_PA 35 36 15 11 12 13 14 21 20 23 25 24 22 SW5 TP8 TP7 TP5 TP6 16 34 31 32 33 30 27 28 26 17 18 19 3.3V PIO11 PIO10 PIO9 PIO0 PIO1 PIO2 PIO3 PIO4 PIO5 PIO6 PIO7 PIO8 USBDN USBDP PCM_IN PCM_CLK PCM_OUT PCM_SY NC R69 100K 10 29 39 40 GND RFIO U1 0.22uF GND GND GND GND C69 38 37 3.3V R73 330 R72 330 R74 330 LED D17 Blue LED / AP2012PBC D16 Link LED D18 Data J2 VCC DD+ GND R71 27 27 R70 USB JACK Title Size Document Number Date: Thursday , June 24, 2010 Rev Sheet of SPP AT Command sets +++ (Escape Sequence) When the device is in Data mode, it can be forced back into Command mode while maintaining the connection to the remote device. The sequence characters should be with 1000ms guard time When it’s in master mode. This command establish a connection. When it’s in slave mode, the command will be rejected. (Establish a Modifiers connection) A1~A8 Description Connect to a device which has been assigned by “ATD= xxxxxxxxxxxx” Connect to a device1~8 in neighborhood found through “ATF?”. This command display the local device BD address (Display local Modifiers BD address) B? Description Inquire the Local BD address This command enable or disable flow control signals (CTS/RTS) of the COM port. Note, the setting is not affected by ATZ0 but will cause a reboot (Flow Control) Modifiers Description C0 Disable flow control. C1 (Default) Enable flow control. C? Inquire the current setting For security purpose, We can specifies the unique remote device can be connected. In master role, it automatically inquire and search the slave even the slave is (Set Remote undiscoverable. In slave role, the command should be as a filter condition to accept the BD address) master’s inquiry. Modifiers Description D=xxxxxxxx "xxxxxxxx" is a string of 12 hexadecimal digits. D0 (Default) Clear Remote BD address setting, inquire any slave in master mode or accept any master in slave mode. D? Inquire the Remote BD address setting This command specifies whether the device should echo characters received from the UART back to the Host (Local Echo) Modifiers Description E0 Characters received from the UART are not echoed back to the Host E1 (Default) Characters received from the UART are echoed back to the Host. E? Inquire the current setting This command is used to find any bluetooth device in neighborhood within 60 seconds timeout. If any device is found, its name and address will be listed. The search ends with a message “Inquiry ends, xx device(s) found.” This command is available only when the adaptor is in the manual master role. An AT (Find Bluetooth can cancel the Inquiry. device) Modifiers Description F? (Discoverable Control) This command is used to drop connection either master or slave role. And it is used to specifiy whether the device could be discovered by remote master device. note : it will cause a reboot when ATH0 or ATH1 take the effect Modifiers Description Drop current connection in Online command mode H0 The device enters undiscoverable mode. If a pair have been made, the original connection could be connected again. Other remote master device can not discovery this device. H1 (Default) The device enters discoverable mode. H? Inquire the current setting This command is used to Inquiry the information (Information) Modifiers Description I0 Inquire the version Codes I1 Listing all setting value I2 Inquire RSSI in Online command mode This command is used to specify one or two stop bits of COM port (Stop setting) Inquire scan max. 8 Bluetooth neighborhood devices. bits Modifiers Description K0 (Default) One Stop bit K1 Two stop bits K? This command is used to specify the baud rate of COM port (Baud Rate Control) (Set name) Modifiers Description L* 1200bps L# 2400bps L0 4800bps L1 9600bps L2 (Default) 19200bps L3 38400bps L4 57600bps L5 115200bps L6 230.4Kbps L7 460.8Kbps L8 921.6Kbps L? Inquire the current setting This command is used to specify the parity bit setting of COM port (Parity setting) Inquire the current setting bits Modifiers Description M0 (Default) None Parity bit. M1 Odd parity setting. M2 Even parity setting M? Inquire the current setting We can specifies the device a friendly name using 0 to 9, A to Z, a to z, space and –, which are all valid characters. Note that "firs space or -, last space or – isn’t permitted". device The default name is “Serial Adaptor” Modifiers Description N=xxxxx "xxxxx" is a character string, maxima length is 16 N? Inquire the device name This command is used to enable/disable auto-connection feature in master role. By the way, it is used to online switch from command mode to data mode. (Auto connect Note, it will cause a reboot when ATO0 or ATO1 take effect. setting) Modifiers Description Online switch from command mode to data mode O0 (Default) Automatically connectting to a device which is assigned in “ATD” or any available device if “ATD” was not assigned. O1 Disable auto-connection feature, user should manually use “ATA” command to connect a remote device. O? Inquire the current setting This command specifies the PIN number. It control to off the PIN code authorization that allow to establish a connection without PIN code. (Set PIN code) Default PIN number is "1234" Modifiers Description P=xxxx (Default) "xxxx" is 4~8 digit string Q (Result Code Supression) P0 Turn off the PIN code authorization P? Inquire the current PIN number The command is used to determine if result Codes should be sent to the Host. When result Codes are supressed, the device does not generate any characters in response to the completion of a command or when an event occurs. Four Result Codes : OK,CONNECT,DISCONNECT,ERROR Modifiers Description Q0 (Default) The device will prompt Result Codes Q1 The device will not prompt Result Codes Q? Inquire the current setting This command specifies whether the device could be master or slave device. If change the role, the adaptor will reboot and clear all paired addresses. (Set Role) Modifiers Description R0 The device as master role. R1 (Default) The device as slave role. R? Inquire the current setting (Escape Control) This command is used to disable/enable escape sequence “+++”. Modifiers Description X0 Disable escape character check. X1 (Default) Enable escape character check. X? Inquire the current setting This command is used to restore default setting and reboot (Restore) Modifiers Description Z0 Restore the default setting The factory settings of UART are as follows: Baud rate: 19200 bps Data bit: 8 Parity: none Stop bit: 1 Flow control: H/W or none BTM-222 Pin Function Pin No. Pin Name Pin Type Description GND PVCC AIO(0) AIO(1) PIO(0) PIO(1) PIO(2) PIO(3) PIO(4) GND Power Bi-directional Bi-directional Bi-directional Bi-directional Bi-directional Bi-directional Bi-directional 10 11 GND PIO(5) GND Bi-directional 12 13 PIO(6) PIO(7) Bi-directional Bi-directional 14 PIO(8) Bi-directional 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 PIO(9) RESETB VCC GND GND USB_DP USB_DN PCM_SYNC PCM_IN PCM_OUT PCM_CLK UART_RX UART_TX UART_RTS GND UART_CTS SPI_MOSI SPI_CSB SPI_CLK SPI_MISO PIO(11) PIO(10) RF_IO GND Bi-directional CMOS input Power GND GND Bi-directional Bi-directional Bi-directional CMOS input CMOS output Bi-directional CMOS input CMOS output CMOS output GND CMOS input CMOS input CMOS input CMOS input CMOS output Bi-directional Bi-directional Analogue GND Common ground Power Amp. Power Supply(3.3V) Programmable I/O terminal Programmable I/O terminal Programmable I/O terminal Programmable I/O terminal Programmable I/O terminal Programmable I/O terminal Programmable I/O terminal, (Button Input, active high) To press the button caused disconnection or reconnection. To double click the button caused clear all original link records then repairing. When user press the button more than 3 seconds, then it will restore the default RS232 setting Common ground Programmable I/O terminal, (Drive Data status led, active high, it will flash 3 times when it reboot). Programmable I/O terminal, (RFCOMM connection status). Programmable I/O terminal, (Drive Link status led, active high, it will flash 3 times when it reboot). Programmable I/O terminal, (Drive Power status led, active high, it will flash 3 times when it reboot). Programmable I/O terminal, (Drive RS232 force on, active high). Reset input of module, Active low 3.3V power supply input Common ground Common ground USB data plus USB data minus Synchronous data sync Synchronous data input Synchronous data output Synchronous data clock UART data input UART data output UART request to send(active low) Common ground UART clear to send(active low) Serial Peripheral Interface data input Chip select for Synchronous Serial Interface(active low) Serial Peripheral Interface clock Serial Peripheral Interface data output Programmable I/O terminal Programmable I/O terminal Antenna interface Common ground BTM-22x Dimension Qualified Product Notice BQB: Juei-Hsin Chin Hyper Taiwan Technology, Inc. 7F-1, No. 92, Sec.1 Nei-Hu Rd., Taipei Taiwan, R.O.C. 114 QPN Number QPNHTTJ050 Assessment Date 11.10.2005 Listing Date 11.10.2005 Applicant Information Applicant Rayson Technology Co., Ltd Contact Person Tim Lin Address 1F, No. 9, R&D Rd. 2, Science-Based Phone Number +886.3.563.3666 Industrial Park, Hsin-Chu, 300 Taiwan, R.O.C Fax Number +886.3.563.3688 http://www.rayson.com Email Address sales@mail.rayson.com URL Manufacturer Information Product Information Product Name Class 1 Module Product Category Components Product ID BTM-22x, BTM-23x Product Type Comp-HW-Integrated Hardware Version A1 Software Version N/A Firmware Version cyt_8unified_fl_bt2.0_19p2 Supported Protocol Supported Profile RF, BB, LM, HCI, HCI-USB, HCI-RS232, HCI-UART, L2CAP, SDP, RFCOMM GAP, SPP Reference Information Product Reference Document V1.0 Bluetooth Specification V2.0 + EDR Test Case Reference List TCRL_EDR_2005-1-BQRB1, TCRL_P1_1_2005-1-BQRB1 I certify that the Class 1Module has a Bluetooth Brand License based on the requirements as described in Section 6.2.1, Pre-Tested Bluetooth Components, of the Bluetooth Program Reference Document 1.0 San Lorenzo, California / 11.10.2005 BTM-222 Regulation Statement --------------------------------------In accordance with FCC Part 15C BTM222, this module is listed as a Limited Modular Transmitter device. Therefore, the final host product must be submitted to Rayson Technology Co., Ltd. for confirmation that the installation of the module into the host is in compliance with the regulations of FCC and IC Canada. Specifically, if an antenna other than the model documented in the Filing is used, a Class 2 Permissive Change must be filed with the FCC. Changes or modifications not expressly approved by the manufacturer could void the user’s authority to operate the equipment. IV. FCC Label Instructions The outside of final products that contains this module device must display a label referring to the enclosed module. This exterior label can use wording such as the following: “Contains Transmitter Module FCC ID: QWOBTM-22X” or “Contains FCC ID: QWOBTM-22X.” Any similar wording that expresses the same meaning may be used.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No Page Count : 12 XMP Toolkit : XMP toolkit 2.9.1-13, framework 1.6 Producer : GPL Ghostscript 9.04 Keywords : () Modify Date : 2012:05:22 18:30:56+08:00 Create Date : 2012:05:22 18:30:56+08:00 Creator Tool : PDFCreator Version 1.2.3 About : bd3d9f3a-a654-11e1-0000-0169c6c5c42..d.2012-05-22T18:30:56+08:00 Document ID : uuid:bd3d9f3a-a654-11e1-0000-0169c6c5c42�\{��c.. Format : application/pdf Title : BTM222 DataSheet Creator : Hoa Description : () Author : Hoa Subject :EXIF Metadata provided by EXIF.tools