Remote Control Solutions RCS433MDR 433.92 MHz Radio Transmitter User Manual 519 Transmitter Instructions
Remote Control Solutions, LLC 433.92 MHz Radio Transmitter 519 Transmitter Instructions
Users Manual
1 - TRANSMITTER INTRODUCTION RCS-433MDR1 1A - General Information R L SE A U NU • The radio control, RCS-433MDR1 has been designed for the control of automatic closing systems and anti-burglar systems. The operating frequency is 433.92 MHz. • The transmitter security code is obtained by means of a 10 way three-state dip-switch, which allows up to 19683 codes combinations. • Each transmitter (or its different keys) can be stored into different receivers and hence can do more functions. • The product fully complies with Part 15 of FCC Regulations. 1B - Technical specifications Number of keys: . . . . . . . . . . . . . . . . . . . . . . . . . .1 Battery duration: . . . . . . . . . . . . . . . . . .12 - 24 months Battery type: . . . . . . . . . . . . . . . . . . . . . . . .23A (L1028) Current consumption: . . . . . . . . . . . . . . . . . . . . .25 mA Thank you for choosing a RCS transmitter. It is recommended that you read this manual carefully before using the transmitter. CONTENTS 1 - TRANSMITTER INTRODUCTION 1A - General Information 1B - Technical Specifications 1C - Main Features 1D - Model Types 2 - CODING 3 - MEMORIZATION 4 - BATTERY AND DIP-SWITCH ACCESS 5 - TROUBLESHOOTING Operating frequency: . . . . . . . . . . . . . . . . .433.92 MHz Security code combinations number: . . . . . . . . .19683 Modulation: . . . . . . . . . . . . . . . . . . . . . . . . . . .AM/ASK E.r.p.: . . . . . . . . . . . . . . . . . . . . . . . . . . . . .50 - 100 uW Range in open space: . . . . . . . . . . .from 100 to 200 m Operating temperature: . . . . . . .from -10 °C to +55 °C Dimensions: . . . . . . . . . . . . . . . . . . . . .1.75 x 1 x .3 in. Weight: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ..7 oz. 1C - Main Features 4 - BATTERY AND DIP-SWITCH ACCESS To access the battery, Using a coin, insert and twist. Place the 23A alkaline battery between the 2 contacts. Respect the right polarity as indicated on the bottom of the box. Red LED Button NOTE:Please dispose of the battery correctly, they are hazardous waste. Dip-Switch Battery 5 - TROUBLESHOOTING 1D - Model Types 1 button dip-switch transmitter: Model #: RCS-433MDR1 2 - CODING Using a coin, insert and twist to access to the battery and the dip-switches. The dip-position will give the security code. Warning:Each transmitter is set-in-factory with the same code on the dip-switches; it highly advisable to change this code by moving the dip-switches to any random position ( “+”, “0” , “-”). The radio signal is not verifiable Replace the transmitter battery The transmitter led doesn't switch on Replace the transmitter battery The radio signal is not verifiable Check the power supply of the receiver The transmitter led switches on Replace the transmitter battery 3 - MEMORIZATION Each dip-switch setting code has to be stored into the receiver memory. The memorization can be done by self-learning. The instructions for this operation is given on the receiver installation manual. Your own installer will perform this operation during the installation or will give you the necessary explanation during installation. RCS-433MDR1 FCC ID: TG6RCS433MDR This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 1) This device may not cause harmful interferences; and GUARANTEE The guarantee period of all RCS transmitters is 12 months, beginning from the manufacturer date. During this period, if the product does not work correctly, due to a defective component, the product will be repaired or substituted at the discretion of RCS. The guarantee does not cover the plastic container integrity. After-sale service is supplied at the producer's factory. 2) this device must accept any interference received, including interference that may cause undesired operation Notice:Any changes or modification to RCS equipment not expressly approved by RCS could void the user's authority to operate the equipment. REMOTE CONTROL SOLUTIONS, LLC 1-866-770-0727 www.rcsremotes.com
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : No Page Count : 2 For : sun l sunl, ptm Create Date : 6/14/2007 3:37 PM Bounding Box : 101 83 511 390 Creator Version : 11 Container Version : 9 Has XFA : No XMP Toolkit : XMP toolkit 2.9.1-13, framework 1.6 About : uuid:231d78d8-314e-4298-8a76-d685b32f1b3b Producer : Adobe PDF library 6.66 Modify Date : 2007:11:08 14:10:03-08:00 Creator Tool : Illustrator Metadata Date : 2007:11:08 14:10:03-08:00 Thumbnail Format : JPEG Thumbnail Width : 256 Thumbnail Height : 192 Thumbnail Image : (Binary data 17189 bytes, use -b option to extract) Document ID : uuid:7634d240-9e29-11da-9a66-0030658ea972 Format : application/pdf Title : 519-Transmitter Instructions Creator : Mel Author : Mel Image Height : 307 Image Width : 410 Image Size : 410x307 Megapixels : 0.126EXIF Metadata provided by EXIF.tools