Remote Control Solutions T433MDT2 Transmitter User Manual 519 Transmitter Instructions
Remote Control Solutions, LLC Transmitter 519 Transmitter Instructions
Users Manual
1 - TRANSMITTER INTRODUCTION RCS-433MDT2 1A - General Information R L SE A U NU • The radio control, RCS-433MDT2 has been designed for the control of automatic closing systems and anti-burglar systems. The operating frequency is 433,92 MHz. • The receiver can be used to control automatic gates, rolling shutters, awnings, anti-burglar appliances, lighting etc. • The transmitter security code is obtained by means of a 9 way three-state dip-switch, which allows up to 19683 codes combinations. All the receivers can store up to 50 different dip-switch code combinations. • Each transmitter (or its different keys) can be stored into different receivers and hence can do more functions. • In order to use the unused keys of the transmitter connect the dedicated receiver to the mechanism to drive (i.e. electro lock of a pedestrian gate, a buzzer, etc. ). • The product fully complies with Part 15 of FCC Regulations. 1B - Technical specifications Number of keys: . . . . . . . . . . . . . . . . . . . . . . . . . .2 Battery duration: . . . . . . . . . . . . . . . . . .12 - 24 months Thank you for choosing a RCS transmitter. It is recommended that you read this manual carefully before using the transmitter. CONTENTS 1 - TRANSMITTER INTRODUCTION 1A - General Information 1B - Technical Specifications 1C - Main Features 1D - Model Types 2 - CODING 3 - MEMORIZATION 4 - BATTERY AND DIP-SWITCH ACCESS 5 - TROUBLESHOOTING Battery type: . . . . . . . . . . . . . . . . . . . . . . . .23A (L1028) Current consumption: . . . . . . . . . . . . . . . . . . . . .25 mA Operating frequency: . . . . . . . . . . . . . . . . .433.92 MHz Security code combinations number: . . . . . . . . .19683 Modulation: . . . . . . . . . . . . . . . . . . . . . . . . . . .AM/ASK E.r.p.: . . . . . . . . . . . . . . . . . . . . . . . . . . . . .50 - 100 uW Range in open space: . . . . . . . . . . .from 100 to 200 m Operating temperature: . . . . . . .from -10 °C to +55 °C Dimensions: . . . . . . . . . . . . . . . . . . . . .1.75 x 1 x .3 in. Weight: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ..7 oz. 1C - Main Features 4 - BATTERY AND DIP-SWITCH ACCESS Red LED Red LED Button Channel A Button Channel B Battery Door 1D - Model Types 2 button dip-switch transmitter: Model #: RCS-433MDT2 To access the battery, slide the battery door down. Place the 23A alkaline battery between the 2 contacts. Respect the right polarity as indicated on the bottom of the box. NOTE: Please dispose of the batteries correctly, they are hazardous waste. Dip-Switch Battery Door Battery 5 - TROUBLESHOOTING FAULT SOLUTION The radio signal is not verifiable Replace the transmitter battery The transmitter led doesn't switch on Replace the transmitter battery The radio signal is not verifiable Check the power supply of the receiver The transmitter led switches on Replace the transmitter battery 2 - CODING Slide open the door to access to the battery and the dip-switches. The dip-position will give the security code. Warning: Each transmitter is set-in-factory with the same code on the dip-switches; it highly advisable to change this code by moving the dip-switches to any random position ( “+”, “0” , “-”). 3 - MEMORIZATION Each dip-switch setting code has to be stored into the receiver memory. The memorization can be done by self-learning. The instructions for this operation is given on the receiver installation manual. Your own installer will perform this operation during the installation or will give you the necessary explanation during installation. TG6T433MDT2 FCC ID: ____________ This device complies with FCC Rules Part 15 Operation is subject to the following two conditions: 1) This device may not cause harmful interferences; 2) this device must accept interference that may cause undesired operation. Notice: Any changes or modification to RCS equipment not expressly approved by RCS could void the user's authority to operate the equipment. GUARANTEE The guarantee period of all RCS transmitters is 12 months, beginning from the manufacturer date. During this period, if the product does not work correctly, due to a defective component, the product will be repaired or substituted at the discretion of RCS. The guarantee does not cover the plastic container integrity. After-sale service is supplied at the producer's factory. REMOTE CONTROL SOLUTIONS, LLC 1-866-770-0727 www.rcsremotes.com
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No Modify Date : 2006:04:06 13:30:39+08:00 Create Date : 2006:02:15 08:46:18-05:00 Page Count : 2 About : uuid:763510d6-9e29-11da-9a66-0030658ea972 Producer : Acrobat Distiller 6.0 for Macintosh Creation Date : 2006:02:15 08:46:18-05:00 Mod Date : 2006:04:06 13:30:39+08:00 Author : Mel Creator Tool : QuarkXPress: pictwpstops filter 1.0 Metadata Date : 2006:04:06 13:30:39+08:00 Document ID : uuid:7634d240-9e29-11da-9a66-0030658ea972 Format : application/pdf Title : 519-Transmitter Instructions Creator : Mel Has XFA : NoEXIF Metadata provided by EXIF.tools