< 1 페이지 > Zigbee Module(MC85A00) Manual Monitoring Device Measuring instrument          MC85A00 (Zigbee Module)  Main Module 1. Introduction : Zigbee Module(MC85A00) is data transfer module, using in measuring instrument. Measuring intstrument contains Natural conditions such as temperature and humidity  2. Features This module receives the command of the main module from the measuring equipment and sends the measured data to the monitoring device or transmits the data received from the monitoring device to the main module. This module is a device that enables measurement equipment to communicate wirelessly (ZIGBEE), and interacts with the main module via UART. It also has a built-in 2.4-MHz amplifier, which helps to transfer data over longer distances.  3. Operation sequence     First, monitoring device request measured data to measuring instrument using ZIGBEE.     Second, zigbee module(MC85A00) request measured data to main module using UART.     Third, main module send measured data to zigbee module(MC85A00) using UART.     Forth,  zigbee module(MC85A00) send measured data to monitoring device using ZIGBEE.
< 2 페이지 > Zigbee Module(MC85A00) Manual Pin Configuration (Top View) Pin No. Pin Name 1  MCU Reset 3  DIO[23] LID 5  DIO[24] Relay 7  DIO[02] DPSW1 9  DIO[03] DPSW2 11 DIO[04] DPSW3 13 DIO[08] LED1 15 DIO[09] LED2 17 DIO[10] LED3 19 DIO[11] LED4 21 VDD 3V3 23 GND Pin No. Pin Name 2  DIO[29] UART Tx 4  DIO[28] UART Rx 6  DIO[30] UART CLK 8  DIO[17] SPI SCLK 10 DIO[19] SPI MOSI 12 DIO[18] SPI MISO 14 DIO[14] SPI CSN 16 DIO[05] I2C SDA 18 DIO[06] I2C SCL 20 DIO[25] MRESET 22 GND 24 GND 4. Hardware information : All control of the Zigbee module is done in CC2630 (TI). CC2592 (TI) is used to increase the communication distance. Between the main module and this module are connected through a pin header and a pin header socket(24pin), each of which has its own function. (See the figure below)
< 3 페이지 > Zigbee Module(MC85A00) Manual 5. Electrical Characteristics     - Absolute Maximum Supply Voltage(DC) : -0.3V ~ 4.1V     - Absolute Maximum Storage Temperature Range : -40˚C ~ 150˚C     - Recommended Operating Voltage : 3.3V (Operable from 1.8V to 3.8V.)      - Receiver sensitivity : -100 dBm (Typ.)     - Receiver saturation : +4 dBm (Typ.)     - Frequency error tolerance : >200ppm     - RSSI dynamic range : 100 dB     - RSSI accuracy : ±4 dB       - Output power : -21 ~ 5 dBm     - Error vector magnityde : 2% (Typ.)  6. Antenna Information     - Material : FR-4     - Thickness : ½ oz     - Surface Treatment : OSP
FCC Information This  device  complies  with  part  15  of  the  FCC  Results.  Operation  is  subject  to  the following two conditions : (1) This device may not cause harmful interface, and (2) This device must accept any interference received, including interference that    may cause undesired operation. Note:  This  equipment  has  been  tested  and  found  to  comply  with  the  limits  for  CLASS  B  digital  device, pursuant to Part 15 of FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates, uses and can radiate radio frequency energy and, if  not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will  not  occur  in  a  particular  installation.  If  this  equipment  does  cause  harmful  interference  to  radio  or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try correct the interference by one or more of the following measures:   1.1. Reorient or relocate the receiving antenna. 1.2. Increase the separation between the equipment and receiver. 1.3. Connect the equipment into an outlet on a circuit different from that to which receiver is connected. 1.4. Consult the dealer or experienced radio/TV technician for help. WARNING Changes  or  modifications  not  expressly  approved  by  the  manufacturer  could  void  the user’s authority to operate the equipment. End product labelling The label for end product must include “Contains FCC ID: TX4MC85A00”. “CAUTION : Exposure to Radio Frequency Radiation. This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment must be installed and operated with minimum distance of 20 cm between the radiator and your body. This transmitter module is authorized only for use in device where the antenna may be installed such that 20 cm may be maintained between the antenna and users.”

Navigation menu