Renishaw plc RMP40 PROBE FOR MACHINE TOOLS User Manual USERS MANUAL

Renishaw plc PROBE FOR MACHINE TOOLS USERS MANUAL

USERS MANUAL

Download: Renishaw plc RMP40 PROBE FOR MACHINE TOOLS User Manual USERS MANUAL
Mirror Download [FCC.gov]Renishaw plc RMP40 PROBE FOR MACHINE TOOLS User Manual USERS MANUAL
Document ID882262
Application IDBfrAFGW+kY5RSpvgFmdAVg==
Document DescriptionUSERS MANUAL
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize155.51kB (1943922 bits)
Date Submitted2007-12-20 00:00:00
Date Available2007-12-21 00:00:00
Creation Date2007-09-19 13:13:27
Producing SoftwareAdobe PDF Library 7.0
Document Lastmod2007-09-19 13:14:23
Document TitleUSERS MANUAL
Document CreatorAdobe InDesign CS2 (4.0.4)

Quick-start guide
H-5480-8500-01-A
RMP40
© 2007 Renishaw plc. All rights reserved.
This document may not be copied or
reproduced in whole or in part, or transferred
to any other media or language, by any means,
without the prior written permission of Renishaw
plc.
The publication of material within this document
does not imply freedom from the patent rights of
Renishaw plc.
Disclaimer
Considerable effort has been made to ensure
that the contents of this document are free
from inaccuracies and omissions. However,
Renishaw makes no warranties with respect to
the contents of this document and specifically
disclaims any implied warranties. Renishaw
reserves the right to make changes to this
document and to the product described herein
without obligation to notify any person of such
changes.
Renishaw part no: H-5480-8500-01-A
Issued: 09.2007
Trademarks
RENISHAW® and the probe emblem used in the
RENISHAW logo are registered trademarks of
Renishaw plc in the UK and other countries.
apply innovation and Trigger Logic are
trademarks of Renishaw plc.
Adobe and Acrobat are either registered
trademarks or trademarks of Adobe Systems
Incorporated in the United States and/or other
countries.
All other brand names and product names
used in this document are trade names, service
marks, trademarks, or registered trademarks of
their respective owners.
CAUTION: The RMP40 has a glass
window, handle with care if broken to
avoid injury
Batteries
Batteries :
1/2 AA (3.6 V) Lithium Thionyl Chloride × 2
Ecocel: 		 EB 1425, EB1426
Dubilier:
SB-AA02
Saft: 		 LS 14250 C, LS 14250
Maxell:
ER3S
Sonnenschein:
SL-750
Sanyo:
CR 14250 SE
Xeno:
XL-050F
Sonnenschein:
SL-350, SL-550
Tadiran:
TL-4902 TL-5902,
TL-2150, TL-5101
Varta:
CR 1/2 AA
Fitting the stylus
M-5000-3707
Installing the batteries
V Take care not to short the 		
battery contacts as this may
be a fire hazard. Ensure the
contact strips are located
securely.
Reviewing the probe settings
>5s
Key to the symbols
LED short flash
LED long flash
LED check
Switch on method
Radio on
(omitted if multiple probe
mode was selected)
Spin on
or
Reviewing the probe settings
Switch off method
Radio off or
Spin off
or
Short time out
12 s
or
Medium time out
33 s
or
Long time out
134 s
Multiple probe mode (omitted for radio-on)
(see ‘Multiple probe mode settings’ to view all 16 choices)
Mode off
Mode on
or
Machine 1
or
Machine 2
Machine 16
Battery status
Battery good
or
Battery low
Probe in standby mode
(after 5 seconds)
Multiple probe mode settings
Deflect
stylus
< 4 sec
to cycle
to next
setting
Multiple probe mode
Mode off
Mode on
Machine 1
Machine 2
Machine 3
Machine 4
Machine 5
Machine 6
Machine 7
Machine 8
Machine 9
Machine 10
Machine 11
Machine 12
Machine 13
Machine 14
Machine 15
Machine 16
Return to mode off
Placing the probe in configuration mode
LED check
>5s
Key to the symbols
Deflect the stylus and hold deflected until
the battery status has been displayed at
the end of the review sequence
LED short flash
LED long flash
Deflect the stylus < 4 seconds
to move to the next menu
option
Battery status
Battery good
or
Battery low
Deflect the stylus > 4 seconds
to move to the next menu
To exit, leave the stylus
untouched for > 20 seconds
To change to switch on method
go to the next page
Changing the probe settings
To change switch on method
Radio on
(omitted if multiple probe
mode was selected)
Spin on
To change switch off method
Radio off or
Spin off
Short timeout
12 s
Medium timeout
33 s
Long timeout
134 s
Acquisition mode
Note: After the RMI
has been acquired, the
RMP40 will only show
Acquisition mode off.
See RMP40 - RMI
partnership.
OFF
ON
Cease triggering here, unless the
multiple probe mode is required in
which case deflect stylus > 4 seconds
New settings
complete
Changing the probe settings (continued)
Multiple probe mode (omitted for radio-on)
(see ‘Multiple probe mode settings’ to view all 16 choices)
Mode off
Mode on
Machine 1
Machine 2
Machine 16
Note: If no changes are made in multiple probe mode, then deflecting the
stylus for more than 4 seconds will return the probe settings to
‘To change switch-on method’
Acquisition mode
OFF
ON
Return to ‘To change switch-on method’
Note: After the RMI has been acquired, the
RMP40 will only show Acquisition mode off.
See RMP40 - RMI partnership.
New settings
complete
RMP40 - RMI partnership
Note: Unless the RMP40 is in
‘Multiple probe’ mode, it will be
necessary to partner it with the
RMI before use.
Note: In configuration mode,
configure settings as required
and then enter the ‘Acquisition
mode’ menu. Select
‘Acquisition mode off’.
Acquisition mode
OFF
ON
Continuously deflect
stylus whilst switching
on the RMI
SIGNAL LED
RMI in acquisition mode
continued on next page
10
RMP40 - RMI partnership
Release and deflect
the stylus to select
‘Acquisition mode on’.
SIGNAL LED
New partner RMP acquired
Probe in standby and
system ready for use
> 20 s
11
Mounting the probe on a shank
2.5 mm AF
×4
12
2.5 mm AF
×2
4 mm AF
2 Nm - 3 Nm
×2
Stylus on-centre adjustment
2,5 mm AF
1 Nm × 4
+10 µm
-10 µm
13
Stylus on-centre adjustment
4 mm AF
6 Nm - 8 Nm
×2
+10 µm
14
-10­ µm
Stylus on-centre adjustment
2.5 mm AF
1,5 Nm - 3,5 Nm
×4
+2.5 µm
-2.5 µm
15
Cleaning
Use clean cloth
16
RMI visual diagnostics
Low battery/start LED
Signal LED
Signal
excellent
Battery low
M code start/stop in
progress
Battery low and
M code start/stop
in progress
Off
Signal good
Signal poor
Off
No signal
In acquisition
mode
Battery is OK and no
M code start/stop in
progress
New partner
RMP acquired
Probe status LED
Error LED
Off
Probe
triggered
Probe
seated
Error
No error
17
Declarations of conformity and compliance
EC DECLARATION OF CONFORMITY
FCC DECLARATION (USA)
Renishaw plc declares that the product:-
FCC Section 15.19
Name:
Description:
This device complies with Part 15 of the FCC
rules. Operation is subject to the following
conditions:
RMP40
Radio machine probe
has been manufactured in conformity with
the following standards:
1. This device may not cause harmful
interference, and
61010-1:2001
2. This device may accept any interference
received, including interference that may
cause undesired operation.
EN 301 489-17
EN 300 328
EN 50371
FCC Section 15.21
and that it complies with the requirements of
directives (as amended):
The user is cautioned that any changes or
modifications not expressly approved by
Renishaw plc, or authorised representative
could void the user’s authority to operate the
equipment.
1999/5/EC
R&TTE radio and 			
telecommunications
terminal equipment
The above information is summarised from
the full EC declaration of conformity. A copy
is available from Renishaw on request.
Patent notice
PATENT NOTICE
Features of the RMP40 probe and features of similar probes are the
subject of one or more of the following patents and/or patent applications:
CN CN1732488A
EP 1734426
TW 200720626
EP 0390342
EP 1804020
US 2004-0178771
EP 0652413
JP
2,945,709
US 2006/0215614A1
EP 065926
JP
2,994,401
US 5,040,931
EP 1185838
JP
2004-279,417
US 5,150,529
EP 1373995
JP
2004-522,961
US 5,212,872
EP 1425550 B
JP
2005-502,035
US 5,279,042
EP 1457786
JP
2006-313567
US 5,669,151
EP 1477767
JP
2006-511860
US 6,776,344 B2
EP 1477768
JP
3,126,767
US 6,941,671 B2
EP 1576560
JP
3967592
EP 1701234
WO 2007/028964
Renishaw plc
New Mills, Wotton-under-Edge,
Gloucestershire, GL12 8JR
United Kingdom
T +44 (0)1453 524524
F +44 (0)1453 524901
E uk@renishaw.com
www.renishaw.com
For worldwide contact details,
please visit our main website at
www.renishaw.com/contact
*H-5480-8500-01*

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
XMP Toolkit                     : 3.1.1-111
About                           : 360b959f-3673-11da-92ed-8a5400d7baa3
Create Date                     : 2007:09:19 13:13:27+01:00
Modify Date                     : 2007:09:19 13:14:23+01:00
Metadata Date                   : 2007:09:19 13:14:23+01:00
Creator Tool                    : Adobe InDesign CS2 (4.0.4)
Thumbnail Format                : JPEG
Thumbnail Width                 : 256
Thumbnail Height                : 256
Thumbnail Image                 : (Binary data 5390 bytes, use -b option to extract)
Version ID                      : 1
Instance ID                     : uuid:af3e275a-6f45-43a8-b5f5-01937158b8a0
Document ID                     : adobe:docid:indd:6aded786-66a7-11dc-b6a2-812df7f75a5e
Rendition Class                 : proof:pdf
Derived From Instance ID        : e77594d3-669e-11dc-8d44-c16d92c2a793
Derived From Document ID        : adobe:docid:indd:e77594d2-669e-11dc-8d44-c16d92c2a793
Derived From Version ID         : 1
Format                          : application/pdf
Producer                        : Adobe PDF Library 7.0
Trapped                         : False
Page Count                      : 22
Creator                         : Adobe InDesign CS2 (4.0.4)
EXIF Metadata provided by EXIF.tools
FCC ID Filing: KQGRMP40

Navigation menu