Residential Control Systems TZW011 Wireless Thermostat User Manual TBZ48 Operation Guide 141 02071 01 052212
Residential Control Systems Wireless Thermostat TBZ48 Operation Guide 141 02071 01 052212
user manual
Operation Guide Model TBZ48 Z-Wave Thermostat Main Thermostat Screen Setpoints Backlite Display Temperature Setting Heating/Cooling Mode Selection OFF MODE Fan Mode Selection Room Temperature FAN AUTO 72H 80C Warmer 74 Cooler RUN Battery Compartment DCN: 141-02071-01 Page 1 Setting the heating or cooling temperature setpoint OFF MODE AUTO FAN 72H 80C 74 Press a button to go to the setpoint change screen RUN Press the up or down arrow buttons to set the desired temperature setpoint Setpoint change screen Setpoint being changed Heat MODE FAN Done Set to 72 Press “DONE” button to set the setpoint and exit back to the main thermostat screen or wait for the screen to automatically time out. Raise Temperature Lower Temperature Pressing the up or down buttons will increment the setpoint 1 degree. Press and hold the button to ramp the setpoint. To change the Heat Setpoint you must be in the Heating mode, to change the Cool Setpoint you must be in the Cooling mode. Pressing the Mode button will switch between the Heat and Cool setpoints. Setpoint Push: Note that you cannot lower the cooling setpoint below the heating setpoint. The thermostat will “push” the heating setpoint lower if you try to lower the cooling setpoint below the heating setpoint. It maintains a 3 degree separation between the heating and cooling setpoint. The same is true for raising the heating setpoint above the cooling setpoint. Again the thermostat will “push” the cooling setpoint up to maintain the 3 degree separation. DCN: 141-02071-01 Page 2 Setting the System Mode: Off, Heat, Cool, Auto Press Mode button to change system mode Off MODE FAN Auto 72H 80C 74 RUN System Modes • Off: System is off. No heating or cooling will come on. If system was on, it will turn off immediately. • Heat: Only heating will occur. • Cool: Only cooling will occur. • Auto: Heating or cooling will come on according to the heating and cooling setpoints. The system will automatically switch between heating and cooling modes as needed to maintain the setpoints. Special Heat Pump Mode: Emergency Heat • Heat-E: An additional system mode, “Heat-E” for Emergency Heat will be displayed if the HVAC system type is set to Heat Pump. If there is a compressor failure with the Heat Pump system, setting the mode to EHEAT will allow the supplemental Aux heat to come on first whenever there is a call for heating. It also disables the compressor output to prevent further damage to the HVAC system. DCN: 141-02071-01 Page 3 Setting Fan Mode Off MODE FAN Auto 72H 80C 74 RUN Press the Fan button to change the Fan mode • • Auto: Fan automatically operated by the HVAC system. On: Manual Fan mode. Fan stays on until mode is changed back to Auto. System Status Indicators System Operation mode indicator displayed > System is ON and heating displayed > System is ON and cooling blinking > System is ON and heating. Minimum Run Time (MRT) delay off is active. blinking > System is ON and cooling. Minimum Run Time (MRT) delay off is active. Staging display “1” > Stage 1 heating or cooling is ON “2” > Stage 2 heating or cooling is ON “3” > Stage 3 heating is ON For Heat Pump systems only: “Heat-E” > emergency heat mode active Run/Home/Away display Run scheduling feature is enabled Hold scheduling feature is disabled (current setpoints are being used) Away setback mode is active (setback setpoints are being used) Notes 1 and 2: See MOT and MRT descriptions on page 9 DCN: 141-02071-01 Page 4 Menu Selection 72H 80C Off MODE FAN Auto 74 RUN Press and hold Fan button to go to the main menu screen Press SELECT to go to the menu item screen MODE FAN SETUP Select Done Use the UP/DOWN buttons to select the desired menu item Press DONE to go back to the main thermostat screen Main Menu Items • • • • • Setup > Basic thermostat settings System > Thermostat configuration settings Time > Clock time Info > Displays thermostat setup info ZWave > ZWave installation Setup Menu Items Deg F/C Select which temperature display mode, Fahrenheit (F) or Celsius (C). SensCal Change the temperature calibration by +/- 7 degrees using the + and – buttons Baklite Sets the time from last button press that the backlite will timeout and turn off. The Backlite will turn OFF after the selected time expires. DCN: 141-02071-01 Page 5 C Away Away setpoints are used when the thermostat is set to the setback or away mode. H Away Away setpoints are used when the thermostat is set to the setback or away mode. System Menu Items Systype Select the system type, HP for HeatPump, S for Standard (Gas/Elec) CO Select the ChangeOver type (HP systems only), changeover with Heat or Cool Fantype Select Fantype (Gas/Elec only), Gas or Electric ZWave Install This menu item allows you to install or uninstall the thermostat into the ZWave network. Follow the instructions in the ZWave Installation section. Thermostat Info The Thermostat Info screen displays the current configuration of the thermostat. This information is useful for quick check of firmware versions and HVAC system setup. It also shows the ZWave network settings. Thermostat information displayed is: • • • • • • Version - Firmware version number. Node ID – ZWave Node ID Home ID –ZWave Home ID System Type - Standard or Heat Pump HVAC system Fan Type – if HVAC type = Standard: Gas or Elect OR Changeover – if HVAC type = Heat Pump: Changeover with cool or changeover with heat. DCN: 141-02071-01 Page 6 Thermostat Operation Minimum Run Time (MRT) The thermostat has a Minimum Run Time after the start of any heating or cooling call. This minimum run time assures even heating and cooling cycles. The MRT delay will keep the system on even if reaches setpoint or you change the setpoint to a temperature that would satisfy the call, until the MRT expires. Changing the Mode to OFF will cancel the MRT and the system will turn off immediately. The MRT can be adjusted in the Installer Settings menu of the thermostat. Note: The MRT status is shown in the thermostat System Status on-screen labels. Minimum Off Time (MOT) The thermostat has a Minimum Off Time after any heating or cooling call is finished. This delay prevents rapid heating/cooling cycles and also provides “short cycle protection” for compressor calls. This delay may be noticeable when you change a setpoint and it does not respond immediately due to another call that has recently completed and the MOT delay timer is preventing the system from restarting. The MOT delay time can be adjusted in the Installer Settings menu of the thermostat. There is a minimum of 5 minutes delay to assure compressor protection. Note: The MOT status is shown in the thermostat System Status on-screen labels. DCN: 141-02071-01 Page 7 Z-Wave® Installation The TBZ48 is based on the Slave Library in the Z-Wave Ecosystem. Z-Wave controllers from various manufacturers support the Z-Wave process of adding or removing a device from a network. The TBZ48 is a Z-Wave Slave and a Z-Wave controller is required as the primary controller to setup and maintain the network. The following procedure will allow the TBZ48 to be included or removed from a Z-Wave network. NOTE: If the TBZ48 is installed on a network while running on Batteries, it will be installed as a FLiRs Z-Wave type of device. If the TBZ48 is installed on a network while powered by the 24VAC, it will be installed as an always listening device and can act as a router in the Z-Wave ecosystem. Once installed, do not change how the thermostat is powered. Inclusion: Including the TBZ48 into an Existing Network: 1. Set your primary controller to Include mode, to add the TBZ48 as a node on your network (see your controller’s user manual for detailed instructions). 2. Press the FAN button and hold until the screen changes to the SETUP screen. 3. Press the UP button until the ZWAVE is shown on the status line, press Select. 4. INSTALL should be shown on the status line, press Select. The status line will show the progress as the TBZ48 has been enrolled into a network. Wait until SUCCESS or FAILED is shown on the status line. 5. Press Done to exit the ZWAVE screen. 6. Press Done again to exit the SETUP screen. The Radio Icon should be shown indicating the TBZ48 is enrolled into a network. Your controller will indicate the TBZ48 was successfully added to its network (see your controller’s user manual for details). Also you can check if the TBZ48 was successfully added to the network by checking the ZHID (Home ID) and ZNID (Node ID) located in the INFO screen. Inclusion and exclusion are always done at normal transmit power mode. If your controller supports NWI, then you can optionally set the primary to NWI include mode. Please note that NWI inclusion mode does not end when you have included a new node. This allows multiple nodes to be included without having to physically go back to the controller to initiate the next inclusion. Therefore you must manually terminate NWI inclusion mode at the controller when you have finished including any new nodes to the network. Since intermediate included nodes will assist the inclusion process by routing messages, we recommend that nodes close to the primary controller be installed first, proceeding out in consecutive rings from the controller. Note: Before adding the TBZ48 to a Z-Wave Network, check that it does not already belong to one by viewing the Home and Zone ID’s located in the INFO screen. An un-configured TBZ48 should show a Node ID of 0 and a random Home ID. Consult DCN: 141-02071-01 Page 8 your controller’s user manual for details on removing a device from a Z-Wave network. Exclusion: Removing the TBZ48 from a Network: 1. Set your primary controller to Remove mode, to remove the TBZ48 as a node on your network (see your controller’s user manual for detailed instructions). 2. Press the FAN button and hold until the screen changes to the SETUP screen. 3. Press the UP button until the ZWAVE is shown on the status line, press Select. 4. REMOVE should be displayed, press Select. The status line will show the progress as the TBZ48 has been removed from a network. Wait until SUCCESS or FAILED is shown on the status line. 5. The controller will indicate the TBZ48 has been removed from the network. The radio icon will disappear from the screen. Setback Mode Operation If your controller does not support full thermostat device class functions, it may still be able to control the energy saving AWAY mode of the thermostat through BASIC_SET commands. Sending the BASIC_SET (Value = 0x00), the thermostat will go into the AWAY mode and use the predefined AWAY setback setpoints. These setpoints are set in the Main Menu Away Setpoints item. Sending the BASIC_SET (Value = 0xFF), the thermostat will revert back to the Home mode it was in before the BASIC_SET (Value = 0x00) command was sent. Note that when the BASIC_SET commands are sent, the TZ45 will momentarily display the new mode. DCN: 141-02071-01 Page 9 FCC/IC INFORMATION TO USER This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for Class B Digital Device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures. • • • • Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio/TV technician for help Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement. DCN: 141-02071-01 Page 10
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : No Page Count : 10 XMP Toolkit : XMP toolkit 2.9.1-13, framework 1.6 About : 57321595-ae72-11e1-0000-9d5ea91f9e7f Producer : GPL Ghostscript 9.02 Keywords : () Modify Date : 2012:06:01 11:22:41-07:00 Create Date : 2012:06:01 11:22:41-07:00 Creator Tool : PDFCreator Version 1.2.1 Document ID : 57321595-ae72-11e1-0000-9d5ea91f9e7f Format : application/pdf Title : TBZ48 Operation Guide 141-02071-01 052212 Creator : Mike Description : () Author : Mike Subject :EXIF Metadata provided by EXIF.tools