Residential Control Systems TZW012 Wireless Thermostat User Manual
Residential Control Systems Wireless Thermostat
user manual
Trane Z-Wave Thermostat TCONT624AZ32DAA Installation and Users Instructions DCN: 140-02089 Rev B 3/07/13 Installation This thermostat is compatible with most HVAC systems, including the following: 24VAC systems Note: requires both the R and C wires unless battery powered. Standard gas/oil/electric heating systems 1 stage heating and cooling 2 stage heating and cooling Heat Pump systems: 1 stage heating and cooling 2 stage heating and cooling 2nd or 3rd stage Auxiliary heating (heat strips) Do NOT use for line voltage controls (120/240VAC) 24VAC Power The thermostat requires both the 24VAC common wire ”C” (typically blue wire) and the 24VAC hot wire, “R” (typically red wire) to operate. If the C wire is not present, an external 24VAC transformer is required. Installation Steps Remove old thermostat Install TZ45H Set up the thermostat for the HVAC system Install into a Z-Wave network Remove old thermostat Turn off power. Usually at the heating/cooling system or circuit- breaker panel. Remove cover of old thermostat to expose the wiring terminals Take a picture of the wiring terminals! Mark the wires attached to the terminals with the wiring labels included Use the terminal labels and not the wiring color to mark the wires Remove the old thermostat base Caution. Don’t let the wires slip into the wall. Take a Picture! Typical thermostat connections. O/B * Note: the C wire (24V common) may not be connected on the old thermostat. ** O or B for Heat Pump systems only C* O or B ** Mark the wires according to the terminal markings. There may be additional wires. Mark these according to the terminal markings. Y1, Y2, W1, W2, RC, RH Taking a picture of the old thermostat wiring terminals before you disconnect them is a good idea. If troubleshooting is required, this information will be extremely useful for the technical support contact. If you need to reinstall the old thermostat, the picture will guide the proper reconnection of the wires. Wiring colors. While the wiring terminals markings are intended to match the wire color (R=red, G=green, W=white, Y=yellow), not all installations were correctly installed this way. Be sure to follow the terminal marking when marking the wires, even if the wire color doesn’t match. Mount the thermostat base Mount the thermostat base to the wall using the wall anchors and screws provided. Level as required. Connect the wires – most common connections A) Single Stage Gas Heating & Cooling System. 24RC Y1 Y2 RS2 RS2 RSC HC C* 24C 24RH W1 RS1 RS1 RSC H1 *C wire (24VAC common) must be installed. If no C wire is available, an external transformer is required. See page x B) Single Stage Heat Pump System 24RC Y1 Y2 RS2 RS2 RSC HC C* O/B** 24C 24RH W1 RS1 RS1 RSC H1 If there are additional wires, see the wiring diagrams on page 4 and 5. Check connections Check that the wires are screwed into the terminal blocks firmly. Gently pull on the wires to confirm the connection. Push all the excess wiring back into the wall. Mount the thermostat Install the thermostat on to the base. Turn on the power at the HVAC system or breaker panel. Wiring Diagrams Standard Gas/Electric HVAC System Thermostat Back 24VAC C 24VAC R Heating stage 1 Heating stage 2 Changeover Fan Compressor Stage 1 Compressor Stage 2 Standard HVAC System Thermostat Connection 24VAC C W1 W2 O/B Y1 Y2 BK RS RS ODT ODT NO NC PWM Fan Speed Remote Temp Sensor Remote Temp Sensor Outdoor Temp Sensor Outdoor Temp Sensor Aux Relay NO Aux Relay Com Aux Relay NC Aux Relay Outputs Normally Closed Contact Common Normally Open Contact 24VAC R Heating stage 1 W1 Outdoor Temp Sensor Heating stage 2 W2 Fan G Compressor Stage 1 Y1 Compressor Stage 2 Y2 PWM Fan Speed BK Remote Indoor Sensor Wiring Diagrams Heat Pump HVAC System Thermostat Back 24VAC C 24VAC R Heating stage 1 Heating stage 2 Changeover Fan Compressor Stage 1 Compressor Stage 2 Heat Pump HVAC System Thermostat Connection 24VAC C W1 W2 O/B Y1 Y2 BK RS RS ODT ODT NO NC PWM Fan Speed Remote Temp Sensor Remote Temp Sensor Outdoor Temp Sensor Outdoor Temp Sensor Aux Relay NO Aux Relay Com Aux Relay NC Aux Relay Outputs Normally Closed Contact Common Normally Open Contact 24VAC R Heating stage 1 W1 Outdoor Temp Sensor Heating stage 2 W2 Changeover O/B Fan G Compressor Stage 1 Y1 Compressor Stage 2 Y2 PWM Fan Speed BK Remote Indoor Sensor Thermostat Setup The thermostat must be set up to match the HVAC System type and configuration for proper operation. Check the current configuration settings by pressing the Menu button to go to the Menu Selection Screen. Then select the Thermostat Info menu item. Thermostat Info Screen Check the HVAC System Type and Fan Type info displayed. If this matches the HVAC system, no further setup is required. If not, press the Setup button to go the HVAC Mechanical settings menu. Thermostat Info TZ45H ZVER: 02.16 ZHID: 00.00.00.00 System Type: Fan Type: Done Ver: 1.02.02 ZNID: 000 Standard Gas Setup Status Press the Setup button to go to the HVAC System Mechanical Settings screen Mechanical Settings Type Gas/Elec Fan Type Gas C/O Type w/Cool 2nd Stage Heat Done Thermostat Setup Select the settings to match the HVAC system: 1. HVAC system type: Gas/Electric or Heat Pump 2. Fan type (for gas/elec systems only): Gas or Electric 3. C/O (changeover valve – for Heat pump systems only) type: w/Cool or w/Heat 4. 2nd Stage Heat: N if no second stage, Y if yes. 5. Aux Heat (for Heat pump systems only): N if no Aux heat, Y if yes 6. 2nd Stage Cool: N if no second stage cooling, Y if yes Advanced System Setup – Installer Settings The TZ45H has advanced system setup options. These settings are accessed in the Installer Settings screen on the thermostat. The Installer Settings is a hidden screen. To access it, press the MENU button to switch to the Menu Selection screen. Press and hold the middle two buttons for 5 seconds to switch to the Installer Settings Screen. Thermostat Main Menu Menu Selection User Settings Away Setpoints ZWave Install Thermostat Info Done Select Press and hold two middle buttons to enter the Installer Settings screen Installer Settings screen Installer Settings Display Lock Service Mode System Settings Max Heat SP Done 90 Select Installer Settings Menu items Display Lock Range: Y or N Default: N Y = Display LOCKED N = Display unlocked Allows you to lock or unlock the thermostat buttons. When the buttons are locked, you can still access the main menu, but you will not be allowed to select any menu options. The Installer Settings hidden button operation is always operational, allowing you to return to this screen and turn Display Lock off. Service Mode Test Mode Range: Y or N Default: N Y= Test mode on. Reduces all delays to 10 sec for quicker system testing N= Test mode off. Normal system delays CAUTION: in test mode all system safety delays are shorten. Do not operate the system compressor in test mode. Disconnect Y1 or Y2 outputs if using test mode on a live system. System Settings Submenu: Sets the HVAC operational settings below Mechanical Settings Submenu: Sets HVAC system type and configuration Type Range: Gas/Elec or Heat pump Selects HVAC type, Gas/Electric or Heat pump Default: Gas/Elec Fan Type Range: Gas or Elec Selects the Fan type if system is Gas or Electric Default: Gas C/O Type Range: w/Cool or w/Heat Selects the Heat Pump Changeover Valve type Default: w/Cool 2nd Stage Heat Range: Y or N Enables the 2nd Stage Heat operation Default: N Aux Heat (HP) Default: Y Range: Y or N Enables the Auxiliary Heat operation. Typically the Aux Heat will be heat-strips in a Heat Pump system 2nd Stage Cool Range: Y or N Enables the 2nd Stage Cool operation Default: N Schedule Enable Range: Y or N Default: N When enabled, the local thermostats scheduler function is enabled. Recovery Enable Range: Y or N Default: N For Heat Pump Systems. Intelligent setback recovery is an automatic advance start of heating to allow the system to be at setpoint by the schedule time, without the use of Aux heating. Delta Settings : The Delta T Setting is the delta, or difference between, the setpoint and current temp for determining when a heat or cool call comes on. The “delta” is the number of degrees away from setpoint. H/C Delta Range: 3 - 15 degrees. Default: 3F (1C) Sets the minimum separation between heating and cooling setpoints. Attempts to lower the cooling below the heating setpoint by this amount will PUSH the heating setpoint down to maintain this separation. Same for setting the heating setpoint above the cooling setpoint, it will PUSH the cooling setpoint up to maintain this separation. Fan Purge Range: 0, 30 to 120 seconds Default: 0 Heating Delta Stage 1 ON Range: 1 to 8 degrees Default: 1 Sets the delta from setpoint that stage 1 heating starts. Heating Delta Stage 1 OFF Range: 0 to 8 degrees Default: 0 Sets the delta from setpoint that stage 1 heating stops. Stage 1 turns off at setpoint + Delta Stage 1. Heating Delta Stage 2 ON Range: 1 to 8 degrees Default: 2 Sets the delta from setpoint that stage 2 heating starts. Heating Delta Stage 2 OFF Range: 0 to 8 degrees Default: 0 Sets the delta from setpoint that stage 2 heating stops. Stage 2 turns off at setpoint + Delta Stage 2. Heating Delta Stage 3 ON Range: 1 to 8 degrees Default: 3 Sets the delta from setpoint that stage 3 heating starts. Heating Delta Stage 3 OFF Range: 0 to 8 degrees Default: 0 Sets the delta from setpoint that stage 3 heating stops. Stage 3 turns off at setpoint + Delta Stage 3. Cooling Delta Stage 1 ON Range: 1 to 8 degrees Default: 1 Sets the delta from setpoint that stage 1 cooling starts. Cooling Delta Stage 1 OFF Range: 0 to 8 degrees Default: 0 Sets the delta from setpoint that stage 1 Cooling stops. Stage 1 turns off at setpoint - Delta Stage 1 Cooling Delta Stage 2 ON Range: 1 to 8 degrees Default: 2 Sets the delta from setpoint that stage 2 cooling starts. Cooling Delta Stage 2 OFF Range: 0 to 8 degrees Default: 0 Sets the delta from setpoint that stage 2 Cooling stops. Stage 2 turns off at setpoint -Delta Stage 2. Max Heat SP Range: 40F to 109F (4C-43C) Default: 90F (32C) Sets the maximum heating setpoint value. Will not ramp or accept setpoints higher that this maximum. Min Cool SP Range: 44F to 113F (6C-45C) Default: 60F (15C) Sets the minimum cooling setpoint value. Will not ramp or accept setpoints lower than this minimum. Minimum Run Time (MRT) Range: 1- 9 Minutes Default: 3 Sets the minimum run time before a heating/cooling cycle can turn off. Sets heating/cooling cycle time. Prevents rapid cycling. Minimum Off Time (MOT) Range: 5-9 Minutes Default: 5 Sets the minimum off time before another heating/cooling cycle can begin. Provides compressor short cycle protection. Fan Cycler The fan cycler function cycles the HVAC system fan for an ON period followed by an Off period continuously. Used to provide minimum air ventilation requirements. When the Fan ON time is set to a value greater than 0, an additional “Cycler” FAN mode is present when pressing the FAN button. Fan ON Time Range: 0-120 minutes Default: 0 (=OFF) Fan OFF Time Range: 10-120 minutes Default: 10 Remote Sensors Submenu for Sensor Setup RS1 Type Range: A curve, Type 2, Type 3 RS2 Type Range: A curve, Type 2, Type 3 RS2 Location Range: IN (indoors), OUT (outdoors) R1 Node ID ID for a Z-Wave remote sensor R2 Node ID ID for a Z-Wave remote sensor Humidity Settings: Submenu for humidity settings Default: Type 3 Default: Type 3 Default: IN Default: 0 Default: 0 RH Display Range: Off or On Turns on or off the RH display on the main thermostat screen. Default: On RH Setpoint Range: 20 to 80 in 5% steps Sets the RH setpoint for Humidity control functions. Default: 55% RH Setpoint Away Range: 20 to 80 in 5% steps Sets the RH setpoint when in the AWAY mode. Default: 65% RH Temp Delta Range: 1 to 5 deg Default: 2 deg Sets the maximum overcooling temperature allowed for humidity control. RH Setpoint Delta Range: 1 to 10 % Default: 5 % Sets the % above the RH setpoint that the Humidity control will be activated. RH On Time Range: 0 to 60 minutes Default: 30 min Sets the maximum runtime for Humidity control to try to correct RH level. RH Off Time Range: 0 to 60 minutes Sets the minimum off time for Humidity control after On time expires. Default: 30 min RH Off Delta Range: 0 to 10 % Default: 2% Sets the % RH below the RH setpoint that the Humidity control will lower the room RH to before turning off. Relay Setup (for aux relay A1 output) A1 Relay mode Range: see below Off. No relay function Humidify: Relay turns on when RH is below humidity setpoint Dehumidify: Relay turns on when RH is above humidity setpoint Net: Z-Wave commands turn Relay On and Off. Configuration parameter #95 See Z-Wave Command Summary Vent: Relay turns on when Vent is active. DH-Fan: HVAC system fan speed control during dehumidification. Default: Off A1 Fan Interlock Range: Off, On Turns on fan output (G) when relay A1 is on Default: Off Restore Defaults Range: Yes, No Restores all settings to factory defaults. Press Yes to restore defaults Press No to exit and not restore defaults Default: No Model XR624 Operation Guide XR624 Thermostat Screen $$$$$$$$$$$$$$$$$ 88: 88 AM PM Wake Day Mon Tue Wed Thu Fri Sat Sun Eve Night Away Vac LOW BATT Temporary Override FILTER SERVICE HUMIDIFIER 8$.5 FC Yes Heating Stg 234 Cooling 88 5 No Done Save AwayBackVac HoldRunESM Off Next EM CoolAutoHeat CircSelectSCF On Auto On Menu Sched Mode Fan Setting the System Mode 1135 AM 75 Menu 70 Run Auto Auto Sched Mode Fan Press MODE button to change system mode System Modes Off: System is off. No heating or cooling will come on. If system was on, it will turn off immediately. Heat: Only heating will occur. Cool: Only cooling will occur. Auto: Heating or cooling will come on according to the heating and cooling setpoints. The system will automatically switch between heating and cooling modes as needed to maintain the setpoints. Special Heat Pump Mode: Emergency Heat Heat-E: An additional system mode, “Heat-E” for Emergency Heat will be displayed if the HVAC System Type is set to Heat Pump. If there is a compressor failure with the Heat Pump system, setting the mode to Emergency Heat will allow the supplemental Aux Heat to come on first whenever there is a call for heating. It also disables the compressor output to prevent further damage to the HVAC system. Caution! Emergency Heat should only be used for emergencies until the HVAC system can be repaired. Running the system in Emergency Heat mode is commonly the most expensive mode since only the electric heat strips are being used instead of the more efficient heat pump compressor. Setting the Heating or Cooling Temperature Setpoint 1135 AM 75 Menu 70 Run Auto Auto Sched Mode Fan Press Up/Down arrow buttons to change setpoint Setpoint Change To change the setpoint, press the Up or Down arrow buttons. The screen will switch to the setpoint change screen (as above) and show the current setpoint of the current heating or cooling mode. Adjust setpoint temperature up or down with the arrow buttons. Note! When in the Setpoint Change screen, pressing the MODE button will switch the setpoint being displayed between the Heat and Cool setpoints. Setpoint Push: The cooling setpoint cannot be set below the heating setpoint. The thermostat will “push” the heating setpoint lower if the cooling setpoint is set below the current heating setpoint. A 3 degree separation is maintained between the heating and cooling setpoints. The same is true for raising the heating setpoint above the cooling setpoint. The thermostat will “push” the cooling setpoint up to maintain the 3 degree separation. Setting the Fan Mode 1135 AM 75 Menu 70 Run Auto Auto Sched Mode Fan Press the FAN button to change the fan mode Fan Modes: Auto: Fan automatically operated by the HVAC system. (normal setting) On: Manual Fan mode. Fan stays on until mode is changed back to Auto, independent of the heating or cooling system operation. Thermostat Menu Mode The Thermostat has a menu of setup and information displays. To change to the Menu Mode, press the Mode button The display will change to the Menu Mode and display the Setup screen. Use the Up/Down arrow buttons to scroll through other menu items. 1135 AM 75 Menu 70 Run Auto Auto Sched Mode Fan Press the Menu button to go to the Menu mode Menu Mode options SETUP SYSTEM ZWAVE CLOCK INFO User preference settings Thermostat HVAC system settings Z-Wave network install or remove Setting the thermostat time and day Displays thermostat version and setup info SETUP Menu User preference settings. FAHRENHEIT OR CELSIUS. Select the temperature display mode. BACKLIGHT TIMEOUT. Sets the time from last button press that the backlight will turn off. Range:10-30 seconds. Note: long backlight timeouts will reduce battery life. If the thermostat is powered from 24VAC, the backlight timeout can be set to “0” which will keep the backlight on continuously. SENSOR CALIBRATION Change the temperature calibration by +/- 7 degrees. Use the Up/Dn arrow buttons to change to the desired display temperature. SYSTEM Menu SYSTEM TYPE. Select the system type, STANDARD or HEAT PUMP FAN TYPE (Standard systems only). Select fan type: GAS (typical default setting) or ELECTRIC CHANGE OVER TYPE (Heat Pump systems only). Select the Changeover type: Changeover WITH COOL (typical default setting) Changeover WITH HEAT See Installation Guide for more information on System setup and the Advanced Systems Menu Z-WAVE Menu This menu item allows the thermostat to be installed or uninstalled from a Z-Wave network. Follow the instructions in the Z-Wave Installation section. INSTALL Press to install the thermostat, if not already installed in a Z-Wave Network (when a controller is in install mode) REMOVE Press to remove the thermostat from a Z-Wave Network CLOCK Menu Set the time and day of the week. Press select to set the DAY. The current day of the week setting will be displayed. Press the UP/DN arrows to change the day of the week desired. Press select to set the TIME. The current time will be displayed. Press the UP/DN arrows to change the time. INFO Menu The INFO menu displays information about the thermostat. Use the Up/Dn buttons to scroll through the various items. Thermostat information displayed: VERSION Thermostat firmware version ZWAVE Z-Wave firmware version NODE ID Z-Wave Node ID HOME ID Z-Wave Home ID SYSTEM TYPE displays current System Type setting If System Type = Standard FAN TYPE displays current Fan Type setting If System Type = Heat Pump CHANGEOVER TYPE displays current Change Over setting Thermostat Operation Minimum Run Time (MRT) The thermostat has a Minimum Run Time (MRT) delay after the start of any heating or cooling call. This minimum run time assures even heating and cooling cycles. The MRT will keep the system on, even if it reaches the setpoint room temperature, or you change the setpoint to a temperature that would satisfy the call, until the MRT expires. Changing the Mode to OFF will cancel the MRT and the system will turn off immediately. The MRT can be adjusted in the Advanced Settings menu of the thermostat. Note: The MRT status is shown in the thermostat Status display. Minimum Off Time (MOT) The thermostat has a Minimum Off Time (MOT) delay after any heating or cooling cycle ends. This delay prevents rapid heating/cooling cycles and also provides “short cycle protection” for the system compressor. This delay may be noticeable when you change a setpoint and it does not respond immediately due to the MOT delay timer preventing the system from restarting. The MOT delay time can be adjusted in the Advanced Settings menu of the thermostat but there is a minimum of 5 minutes delay to assure compressor protection. Note: The MOT status is shown in the thermostat Status display. Z-Wave® Operation The XR624 is based on the Slave Library in the Z-Wave Ecosystem. Z-Wave controllers from various manufacturers support the Z-Wave process of adding or removing a device from a network. The thermostat is a Z-Wave Slave and a Z-Wave controller is required as the primary controller to setup and maintain the network. The following procedure will allow the thermostat to be installed (inclusion) or removed (exclusion) from a Z-Wave network. NOTE: If the thermostat is installed in a network while running on batteries, it will be installed as a FLiRs Z-Wave type of device. This is a power saving mode that converses the batteries by keeping the radio asleep most of the time. However, in this mode, the thermostat does not act as a router node in the Z-Wave network. If the THERMOSTAT is installed in a network while powered by 24VAC, it will be installed as an always-listening device and can act as a router node in the Z-Wave network. Caution! Once installed in a Z-Wave network, if you change how the thermostat is powered (from batteries to 24VAC or vice versa), you must remove and re-install the thermostat in the Z-Wave network for it to work correctly. Before installing the thermostat into a Z-Wave Network, check that is not already installed in a network by viewing the Home and Zone ID’s located in the INFO screen. An un-installed thermostat will show a Node ID of 0. Consult your controller’s user manual for details on removing a device from a Z-Wave network. Inclusion: Installing the thermostat into an existing Z-Wave network 1. Set your primary controller to Install or Include mode, to add the THERMOSTAT as a node on your network (see your controller’s user manual for detailed instructions). 2. Press the FAN button and hold until the screen changes to the Menu screen. 3. Press the UP button until ZWAVE is shown in the Status Display line then press Select. 4. INSTALL should be shown on the status line. Press Select to install in the network. The status line will show the progress as the THERMOSTAT is added into the network. Wait until SUCCESS or FAILED is shown on the status display. 5. Press Done to exit the ZWAVE screen. 6. Press Done again to exit the Menu screen. 7. The Radio Icon should be shown in the Thermostat Main screen indicating the thermostat is enrolled into a network. Your controller will indicate the thermostat was successfully added to its network (see your controller’s user manual for details). Also you can check if the thermostat was successfully added to the network by checking the Node ID and Home ID in the INFO screen. Z-Wave Network Note: Inclusion and exclusion are always done at normal transmit power mode. Network Wide Inclusion If your controller supports Network Wide Inclusion (NWI), then you can optionally set the primary to NWI include mode. Please note that NWI inclusion mode does not end when you have included a new node. This allows multiple nodes to be included without having to physically go back to the controller to initiate the next inclusion. Therefore you must manually terminate NWI inclusion mode at the controller when you have finished including any new nodes to the network. Since intermediate included nodes will assist the inclusion process by routing messages, we recommend that nodes close to the primary controller be installed first, proceeding out in consecutive rings from the controller. Exclusion: Removing the thermostat from a Z-Wave network 1. Set your primary controller to Uninstall or Remove mode to remove the thermostat as a node on your network (see your controller’s user manual for detailed instructions). 2. Press the FAN button and hold until the screen changes to the Menu screen. 3. Press the UP button until ZWAVE is shown on the status line then press Select. 4. REMOVE should be displayed. Press Select to remove from the network. The status display will show the progress as the thermostat has been removed from a network. Wait until SUCCESS or FAILED is shown on the status line. 5. The controller will indicate the thermostat has been removed from the network. 6. The Radio Icon will disappear from the Thermostat Main screen. Note: You can confirm the thermostat has been removed by checking that the Node ID is 0 in the INFO screen. FCC/IC INFORMATION TO USER This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for Class B Digital Device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures. Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio/TV technician for help Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. This Class B digital apparatus complies with Canadian ICES-003. Cet appareil numérique de la classe[B est conforme à la norme NMB-003 du Canada. Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : No Page Count : 17 Language : en-US Tagged PDF : Yes Author : Michael Kuhlmann Creator : Microsoft® Word 2010 Create Date : 2013:03:07 10:19:15-08:00 Modify Date : 2013:03:07 10:19:15-08:00 Producer : Microsoft® Word 2010EXIF Metadata provided by EXIF.tools