Resolution RE112 Wireless Smoke Detector User Manual RE112 GE Compat Smoke Instructions
Resolution Products, Inc. Wireless Smoke Detector RE112 GE Compat Smoke Instructions
User Manual
Specifications Approval: Smoke Sensitivity: Wireless Security Solutions RE112 GE-Compatible Smoke Sensor DSC Features • UL217 Self-Contained Fire Alarm Device • Senses Smoke per UL217 • Sleek design • Cover tamper. • Strong, reliable RF signal. • 3-5 year battery life on Panasonic CR123A battery. • Low Battery indication. UL217 Self-Contained Fire Alarm Device 1.31 – 2.28 %/ft (UL 217) 0.11 – 0.165 dB/m (EN54-7) Smoke Sensing Technology: Photoelectric Heat Alarm Point: 135 – 149 F (UL 521) Alarm Sound: Temporal Three Replacement Battery: Panasonic CR123A Temperature Range: 32 to 120 F (Long Term) Humidity: 10 – 85% Relative Humidity Housing dimensions: 4.7 inch diameter, 2.1 inch high Desing & Manufacture: Resolution Products, Inc. Specifications subject to change without notice. Key Instructions 1. Attach the mounting plate Locate on ceiling, as close to center as possible, away from corners. Some local codes may allow wall mounting. Mounting plate removes counter-clockwise 2. Insert battery with MINUS towards the RED lever. Close battery door. 3. Enroll sensor in panel: a) Place panel in Learn Sensor mode b) Press & release the black tamper switch Sounder will continue beeping 3 times, until sensor is mounted. 4. Testing: a) Place panel in Sensor Test mode b) Press & hold TEST button until you hear the sounder beep. c) Panel will indicate the sensor is open, but Fire Alarm will not sound. NOTE: Using Smoke-in-a-Can will cause an actual Fire Alarm. Pictures Tamper Mounting Tabs Smoke Sensing Element Operation Situation Sounder LED Actual smoke Temporal 3 (Loud) RED (pulsing) Press & hold Test Button Temporal 3 (Loud) RED (pulsing) Sensor Open signal to panel Removing Sensor from Mount Low Battery Temporal 3 (Loud) Orange (steady) Tamper/Trouble signal to be sent to panel. Hourly Check Wireless Signal to Panel Wireless Fire Alarm Signal sent to panel Battery Recovery Silence an actual alarm with the TEST button. Sensor will return to alarm if smoke is still present. Sensor: Release button. Panel: Wait one hour, or unmount & mount sensor. Restore by remounting. TEST Button LED Yellow (pulsing) Supervisories, every hour RE112_GE-Compat_Smoke_Instructions.doc Page 1 of 3 www.ResolutionProducts.com 30-Jul-13 RE112_GE-Compat_Smoke_Instructions.doc Page 2 of 3 www.ResolutionProducts.com 30-Jul-13 Notices Verify proper enrollment and operation, per control panel installation instructions, at installation. PHOTOELECTRIC SMOKE & HEAT USER'S MANUAL, which is included in device box, is an integral part of the operating information of the RE112 device. However, this is NOT a heat device. Approved as a self-contained fire alarm device per UL217. This represents the ability of each individual sensor to sound locally upon sensed fire conditions. “GE”, “Interlogix”, “Honeywell”, “2GIG”, “DSC”, “Napco” are trademarks owned by General Electric Company, UTC Fire & Security Americas Corporation, Inc., Honeywell International Inc., 2GIG Technologies Inc., Tyco Safety Products Canada LTD, Napco Security Systems respectively. Resolution Products, Inc. products will function with one of either GE/Interlogix, Honeywell and 2GIG, DSC or Napco. However, no Resolution product is produced by, endorsed by, nor is officially associated with any of these other manufacturers. Resolution recommends verifying proper enrollment and operation, per control panel installation instructions, at installation. Warranty Resolution Products, Inc. will replace products that are defective in their first 5 years. FCC Notice This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: This device may not cause harmful interference. This device must accept any interference that may be received, including interference that may cause undesired operation. Changes or modifications not expressly approved by the Resolution Products, Inc. could void the user's authority to operate this equipment. FCC ID: U5X-RE112 IC Notice This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: 1. This device may not cause interference, and 2. This device must accept any interference, including interference that may cause undesired operation of the device. Cet appareil est conforme avec d’Industrie Canada RSS standard exempts de licence. Son fonctionnement est soumis aux deux conditions suivantes: 1. Ce dispositif ne peut causer des interférences, et 2. Ce dispositif doit accepter toute interférence, y compris les interférences qui peuvent causer un mauvais fonctionnement du dispositif. IC: 8310A-RE112 RE112_GE-Compat_Smoke_Instructions.doc Page 3 of 3 www.ResolutionProducts.com 30-Jul-13
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : No Page Count : 2 XMP Toolkit : XMP toolkit 2.9.1-13, framework 1.6 About : uuid:920583d3-26df-11e3-0000-c52530335abd Producer : PDF Printer / www.bullzip.com / CP / Freeware Edition Modify Date : 2013:09:23 14:12:21-05:00 Create Date : 2013:09:23 14:12:21-05:00 Creator Tool : UnknownApplication Document ID : uuid:920583d3-26df-11e3-0000-c52530335abd Format : application/pdf Title : RE112_GE-Compat_Smoke_Instructions Creator : Martini Author : MartiniEXIF Metadata provided by EXIF.tools