Resolution RE201X Security Transmitter, 345MHz User Manual RE201 Honeywell Compat DWS Instructions
Resolution Products, Inc. Security Transmitter, 345MHz RE201 Honeywell Compat DWS Instructions
User Manual
Wireless Security Solutions RE201 Honeywell-Compatible Standard Door / Window Features • For sensing things that open or separate. • Magnet and Internal reed switch. • 2 supplemental hardwire zones. o Outer terminal. o Inner terminal. • Cover tamper. • Strong, reliable RF signal. • 10-15 year battery life on CR123A battery. • Low Battery indication. Key Instructions • Battery “+” faces towards spring. • Panels assume hardwire zone alarm is state in which contact was enrolled. • Loops: Reed switch = Loop 2. External Contact Terminals: • Outer terminal = Loop 1. • Inner terminal = Loop 3. • Center hardwire terminal is common. • No end-of-line resistors on hardwire zones. • Ext Loops are: normally closed – alarm on open Tamper = Loop 4 • Enrolling: Place Panel in RF Learning mode. Input Type = RF Lynx *56 “E I” mode: To enroll any particular loop: cause the loop to fault… restore… (panel should beep to indicate ID capture)… fault… restore… [panel will confirm enrollment]. Vista *56 “10 INPUT S/N: L” mode: Transmit two open/close sequences. Press * (to check for duplicate serial/loop number). Press * (to continue to confirmation screen). Press * if you wish to skip confirmation; or “Yes” and activate the loop to confirm. RE201_Honeywell-Compat_DWS_Instructions.doc Page 1 of 3 6/29/2011 www.ResolutionProducts.com Operation • Magnetic reed switch (Loop 2): Alarm, when magnet is pulled away from reed switch. • Hardwire zones (Outer=Loop 1, Inner=Loop 3) Alarm: when contact changes to alarm condition. Tamper: none. • Tamper (Loop 4), when cover is opened. • Supervisories, every hour. Specifications Magnet trip distance: Mounting hardware: Replacement Battery: Temperature Range: Housing dimensions: 1 inch nominal # 4 or #6 screws CR123A 1550mAH 0F to 120F 3.3x1.4x1.1 inches Specifications subject to change without notice. Internal Picture Loop 4 Tamper Loop 3 Inner Terminal Zone Center Common Terminal Loop 1 Outer Terminal Zone Loop 2 Magnetic Reed Switch RE201_Honeywell-Compat_DWS_Instructions.doc Page 2 of 3 6/29/2011 www.ResolutionProducts.com Notices “GE”, “Honeywell”, and “DSC” are trademarks owned by General Electric Company, Honeywell International Inc., and Tyco Safety Products Canada LTD, respectively. Resolution Products, Inc. products will function with one of either GE, DSC or Honeywell systems. However, no Resolution product is produced by, endorsed by, nor is officially associated with GE, Honeywell or DSC. Resolution recommends verifying proper enrollment and operation, per control panel installation instructions, at installation. Warranty Resolution Products, Inc. will replace products that are defective in their first year. FCC Notice This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: This device may not cause harmful interference. This device must accept any interference that may be received, including interference that may cause undesired operation. Changes or modifications not expressly approved by the Resolution Products, Inc. could void the user's authority to operate this equipment. FCC ID: U5X-RE201X IC Notice This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: 1. This device may not cause interference, and 2. This device must accept any interference, including interference that may cause undesired operation of the device. Cet appareil est conforme avec d’Industrie Canada RSS standard exempts de licence. Son fonctionnement est soumis aux deux conditions suivantes: 1. Ce dispositif ne peut causer des interférences, et 2. Ce dispositif doit accepter toute interférence, y compris les interférences qui peuvent causer un mauvais fonctionnement du dispositif. IC: 8310A-RE201X RE201_Honeywell-Compat_DWS_Instructions.doc Page 3 of 3 6/29/2011 www.ResolutionProducts.com
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No Page Count : 2 XMP Toolkit : XMP toolkit 2.9.1-13, framework 1.6 About : 6cb480c0-a4d3-11e0-0000-17aa02f0b296 Producer : GPL Ghostscript 8.64 Keywords : () Modify Date : 2011:06:29 12:47:50-05:00 Create Date : 2011:06:29 12:47:50-05:00 Creator Tool : \376\377\000P\000D\000F\000C\000r\000e\000a\000t\000o\000r\000 \000V\000e\000r\000s\000i\000o\000n\000 \0000\000.\0009\000.\0008 Document ID : 6cb480c0-a4d3-11e0-0000-17aa02f0b296 Format : application/pdf Title : \376\377\000R\000E\0002\0000\0001\000_\000H\000o\000n\000e\000y\000w\000e\000l\000l\000-\000C\000o\000m\000p\000a\000t\000_\000D\000W\000S\000_\000I\000n\000s\000t\000r\000u\000c\000t\000i\000o\000n\000s Creator : \376\377\000b\000s\000e\000e\000m\000a\000n\000n Description : () Author : bseemann Subject :EXIF Metadata provided by EXIF.tools