Revogi Innovation SGW001 Smart Sensor Gateway with Sub-G and Wi-Fi User Manual 2

Revogi Innovation Co., Ltd. Smart Sensor Gateway with Sub-G and Wi-Fi 2

User Manual

Download: Revogi Innovation SGW001 Smart Sensor Gateway with Sub-G and Wi-Fi User Manual                      2
Mirror Download [FCC.gov]Revogi Innovation SGW001 Smart Sensor Gateway with Sub-G and Wi-Fi User Manual                      2
Document ID3252044
Application IDuCKBKM2ODF1gRtQK8DYlHQ==
Document DescriptionUser Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize209.44kB (2617979 bits)
Date Submitted2017-01-09 00:00:00
Date Available2017-01-09 00:00:00
Creation Date2016-11-29 14:24:55
Producing SoftwareCorel PDF Engine Version 16.1.0.843
Document Lastmod2017-01-06 19:47:06
Document Title未命名 -2
Document CreatorCorelDRAW X6
Document Author: design

About
Product Introduction
Specification
Thanks for your choice of Revogi Smart Sense Kit. This is a quick
installation guide for you. Please read this entire guide attentively
before using our products. Revogi Smart Sense Kit centers on
Smart Sensor Gateway, co-works with Door Sensor, Motion
Sensor, Smart Button and Smoke Detector. After some simple
configurations, one can use Smart Sense Kit to remotely monitor
indoor temperature, humidity, pressure, ambient light, noise level, etc,
cooperate with other Revogi devices to bring safety and smart life into
your home.
Quick Installation Guide
Smart Sense Kit
for Smart Sensor Gateway User Manual
Smart Sensor Gateway
Model: SGW001
Power Source: DC 5V1A
Humidity Measurement: 5 to 95% RH, Tolerance: ±4%
Pressure Measurement: 300 to 1200mbar, Tolerance: ±3mbar
Ambient Light Measurement: 0-83000lux, Tolerance: ±3%
Noise Measurement: 30-130db, Tolerance: ±3%
Communication Protocol: WiFi-868MHz
Operating Temperature: 32 to 104°F, 0 to 40°C (indoor only)
Motion Sensor
Smoke Detector
Sense the movement in the surrounding environment by infrared
detection.
Trigger the Smart Sensor Gateway to alarm when detecting any
smoke.
Indicator
Smart Sensor Gateway
Revogi Smart Sensor Gateway features the control center of the Smart
Sense Kit, and the sensors can be linked with more smart devices via
Smart Gateway.
Loudspeaker
Touch Button
Light Induction Zone
Indicator
Indicator
Indicator
Door Sensor
Reset Button
Pairing Button
Model: SSW002
Power Source: CR2032 (included)
Battery Lifespan: 5years(10 times trigger per day)
Range: 70M, 230Ft Min. (depending your home's construction)
Communication Protocol: Proprietary 868MHz
Operating Temperature: 32 to 104°F, 0 to 40°C (indoor only)
Reset Button
Status
Ready for connect
network
Device
successfully
Stays green for 5s then off connected
with router
Smart Sensor Slow green flashing
Connecting network
Gateway
(twice per sec)
Quick blue flashing
Ready for paring sensor
(4 times per sec)
New sensor pairs
Stays blue for 5s then off successfully
Motion Sensor
Model: SSW003
Power Source: AA size, LR6 type, 2PCS (included)
Battery Lifespan: 2 years (100 times trigger per day)
Field of View/ Focal Length: 120 degrees, 5M
Range: 70M, 230Ft Min. (depending your home's construction)
Communication Protocol: Proprietary 868MHz
Operating Temperature: 32 to 104°F, 0 to 40°C (indoor only)
Smart Sensor Gateway
Smoke Detector
Smart Botton
Model: SSW004
Power Source: CR2032 (included)
Battery Lifespan: 5years(10 times trigger per day)
Range: 70M, 230Ft Min.(depending your home's construction)
Communication Protocol: Proprietary 868MHz
Operating Temperature: 32 to 104°F, 0 to 40°C (indoor only)
Indicator
Door Sensor
Monitor doors and windows by sensing opening and closing between
the main part and the magnet.
Smart Button
Trigger the Smart Sensor Gateway to ring door bell by pressing the
button.
Pairing Button
Quick Instruction
1. Download APP
Scan with your smartphone or tablet or search for "RevogiHome"
in the App Store or Google Play.
Download RevogiHome, sign up or log in directly.
MotionSensor
Smart Button
Blue flashing(once)
Open / Close
Blue flashing(once)
Trigger
Smart Button Blue flashing(once)
Ring
Smoke Detector Red flashing
Alarm
Button
Button
Function
Pairing Button
Indicator
Slight touch: De-alerting
Smart Sensor Touch Button
Gateway
Reset Button
Indicator
Long touch: Entering pairing mode
Long press till green light flashes quickly
Pairing Button Press to pair
Pairing Button Press to pair
Smoke Detector
Door Sensor
Description
Quick green flashing
(4 times per sec)
Model: SSW005
Power Source: 6LR61 9V (included)
Battery Lifespan: 5 years
Range: 70M, 230Ft Min. (depending your home's construction)
Communication Protocol: Proprietary 868MHz
Operating Temperature: 32 to 104°F, 0 to 40°C (indoor only)
Smart Button Pairing Button Press to pair
Pairing Button Press to pair
Smoke Detector
Magnet
Pairing Button
Main Part
Motion Sensor
3. AddSmart Sensor Gateway
4. AddSensors
Make sure your smartphone or tablet is connected to the Wi-Fi. Tap
“Add new device” below the app page and select Smart Sense, then
follow the prompts to configure your device.
Put finger on the Touch button of the Smart Sensor Gateway or tap “Add
New Sensor” in the Smart Sense page to start the pairing, then use a
needle to press the paring button on the sensor, an voice prompt
"The sensor is paired" and the gateway indicator stays blue will
indicate the pairing successful.
Door Sensor
Reset Button
Press to stop the alarm
Smoke Detector
Smart Button
Smart Button
9V
1. Open back cover
Motion Sensor
1. Open back cover
2. Take off the insulating spacer
Android: more than 800x480 resolution, Android 4.3+;
iOS: iOS8.0+
1. Open the back cover
2. Load the 6LR61 9V battery
3. Close back cover
4. Mount on ceiling
2. Mount the bracket, Scew on
5m
120°
Door Sensor
5m
5m
Smoke Detector
9V
2. Plug into the power outlet
1. Load battery with 2pcs AA
2. Take off the insulating spacer
3. Colse back cover
5m
120°
3. Colse back cover
4. Less than 22mm
For technical support please visit:www.revogi.com/support
Or email:support@revogi.com
FCC Part 15.19 Warning Statement
THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES. OPERATION
IS SUBJECT TO THE FOLLOWING TWO CONDITIONS: (1) THIS DEVICE MAY
NOT CAUSE HARMFUL INTERFERENCE, AND (2) THIS DEVICE MUST
ACCEPT ANY INTERFERENCE RECEIVED, INCLUDING INTERFERENCE THAT
MAY CAUSE UNDESIRED OPERATION.
FCC Part 15.21 Warning Statement
NOTE:
THE GRANTEE IS NOT RESPONSIBLE FOR ANY CHANGES OR
MODIFICATIONS NOT EXPRESSLY APPROVED BY THE PARTY RESPONSIBLE FOR
COMPLIANCE. SUCH MODIFICATIONS COULD VOID THE USER’S AUTHORITY TO
OPERATE THE EQUIPMENT.
FCC Part 15.105 Warning Statement
Note: This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a residential installation. This equipment
generates, uses and can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular installation. If
this equipment does cause harmful interference to radio or television reception, which can be
determined by turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
—Reorient or relocate the receiving antenna.
—Increase the separation between the equipment and receiver.
—Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected.
—Consult the dealer or an experienced radio/TV technician for help.
RF warning statement:
The device has been evaluated to meet general RF exposure requirement.
To maintain compliance with FCC's RF exposure guidelines, this equipment should be
installed and operated with a minimum distance of 20cm between the radiator and your body.

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : No
Has XFA                         : No
XMP Toolkit                     : Adobe XMP Core 5.4-c005 78.147326, 2012/08/23-13:03:03
Format                          : application/pdf
Creator                         : design
Title                           : 未命名 -2
Create Date                     : 2016:11:29 14:24:55+08:00
Creator Tool                    : CorelDRAW X6
Modify Date                     : 2017:01:06 19:47:06+08:00
Metadata Date                   : 2017:01:06 19:47:06+08:00
Producer                        : Corel PDF Engine Version 16.1.0.843
Document ID                     : uuid:15139b49-fdce-49e2-992f-10408e8edbef
Instance ID                     : uuid:b605840c-b6e8-4b86-987b-3528ce607557
Page Count                      : 2
Profile CMM Type                : Lino
Profile Version                 : 2.1.0
Profile Class                   : Display Device Profile
Color Space Data                : RGB
Profile Connection Space        : XYZ
Profile Date Time               : 1998:02:09 06:49:00
Profile File Signature          : acsp
Primary Platform                : Microsoft Corporation
CMM Flags                       : Not Embedded, Independent
Device Manufacturer             : IEC
Device Model                    : sRGB
Device Attributes               : Reflective, Glossy, Positive, Color
Rendering Intent                : Perceptual
Connection Space Illuminant     : 0.9642 1 0.82491
Profile Creator                 : HP
Profile ID                      : 0
Profile Copyright               : Copyright (c) 1998 Hewlett-Packard Company
Profile Description             : sRGB IEC61966-2.1
Media White Point               : 0.95045 1 1.08905
Media Black Point               : 0 0 0
Red Matrix Column               : 0.43607 0.22249 0.01392
Green Matrix Column             : 0.38515 0.71687 0.09708
Blue Matrix Column              : 0.14307 0.06061 0.7141
Device Mfg Desc                 : IEC http://www.iec.ch
Device Model Desc               : IEC 61966-2.1 Default RGB colour space - sRGB
Viewing Cond Desc               : Reference Viewing Condition in IEC61966-2.1
Viewing Cond Illuminant         : 19.6445 20.3718 16.8089
Viewing Cond Surround           : 3.92889 4.07439 3.36179
Viewing Cond Illuminant Type    : D50
Luminance                       : 76.03647 80 87.12462
Measurement Observer            : CIE 1931
Measurement Backing             : 0 0 0
Measurement Geometry            : Unknown
Measurement Flare               : 0.999%
Measurement Illuminant          : D65
Technology                      : Cathode Ray Tube Display
Red Tone Reproduction Curve     : (Binary data 2060 bytes, use -b option to extract)
Green Tone Reproduction Curve   : (Binary data 2060 bytes, use -b option to extract)
Blue Tone Reproduction Curve    : (Binary data 2060 bytes, use -b option to extract)
Author                          : design
EXIF Metadata provided by EXIF.tools
FCC ID Filing: 2ACQ5SGW001

Navigation menu