Revogi Innovation SGW001 Smart Sensor Gateway with Sub-G and Wi-Fi User Manual 2
Revogi Innovation Co., Ltd. Smart Sensor Gateway with Sub-G and Wi-Fi 2
User Manual
About Product Introduction Specification Thanks for your choice of Revogi Smart Sense Kit. This is a quick installation guide for you. Please read this entire guide attentively before using our products. Revogi Smart Sense Kit centers on Smart Sensor Gateway, co-works with Door Sensor, Motion Sensor, Smart Button and Smoke Detector. After some simple configurations, one can use Smart Sense Kit to remotely monitor indoor temperature, humidity, pressure, ambient light, noise level, etc, cooperate with other Revogi devices to bring safety and smart life into your home. Quick Installation Guide Smart Sense Kit for Smart Sensor Gateway User Manual Smart Sensor Gateway Model: SGW001 Power Source: DC 5V1A Humidity Measurement: 5 to 95% RH, Tolerance: ±4% Pressure Measurement: 300 to 1200mbar, Tolerance: ±3mbar Ambient Light Measurement: 0-83000lux, Tolerance: ±3% Noise Measurement: 30-130db, Tolerance: ±3% Communication Protocol: WiFi-868MHz Operating Temperature: 32 to 104°F, 0 to 40°C (indoor only) Motion Sensor Smoke Detector Sense the movement in the surrounding environment by infrared detection. Trigger the Smart Sensor Gateway to alarm when detecting any smoke. Indicator Smart Sensor Gateway Revogi Smart Sensor Gateway features the control center of the Smart Sense Kit, and the sensors can be linked with more smart devices via Smart Gateway. Loudspeaker Touch Button Light Induction Zone Indicator Indicator Indicator Door Sensor Reset Button Pairing Button Model: SSW002 Power Source: CR2032 (included) Battery Lifespan: 5years(10 times trigger per day) Range: 70M, 230Ft Min. (depending your home's construction) Communication Protocol: Proprietary 868MHz Operating Temperature: 32 to 104°F, 0 to 40°C (indoor only) Reset Button Status Ready for connect network Device successfully Stays green for 5s then off connected with router Smart Sensor Slow green flashing Connecting network Gateway (twice per sec) Quick blue flashing Ready for paring sensor (4 times per sec) New sensor pairs Stays blue for 5s then off successfully Motion Sensor Model: SSW003 Power Source: AA size, LR6 type, 2PCS (included) Battery Lifespan: 2 years (100 times trigger per day) Field of View/ Focal Length: 120 degrees, 5M Range: 70M, 230Ft Min. (depending your home's construction) Communication Protocol: Proprietary 868MHz Operating Temperature: 32 to 104°F, 0 to 40°C (indoor only) Smart Sensor Gateway Smoke Detector Smart Botton Model: SSW004 Power Source: CR2032 (included) Battery Lifespan: 5years(10 times trigger per day) Range: 70M, 230Ft Min.(depending your home's construction) Communication Protocol: Proprietary 868MHz Operating Temperature: 32 to 104°F, 0 to 40°C (indoor only) Indicator Door Sensor Monitor doors and windows by sensing opening and closing between the main part and the magnet. Smart Button Trigger the Smart Sensor Gateway to ring door bell by pressing the button. Pairing Button Quick Instruction 1. Download APP Scan with your smartphone or tablet or search for "RevogiHome" in the App Store or Google Play. Download RevogiHome, sign up or log in directly. MotionSensor Smart Button Blue flashing(once) Open / Close Blue flashing(once) Trigger Smart Button Blue flashing(once) Ring Smoke Detector Red flashing Alarm Button Button Function Pairing Button Indicator Slight touch: De-alerting Smart Sensor Touch Button Gateway Reset Button Indicator Long touch: Entering pairing mode Long press till green light flashes quickly Pairing Button Press to pair Pairing Button Press to pair Smoke Detector Door Sensor Description Quick green flashing (4 times per sec) Model: SSW005 Power Source: 6LR61 9V (included) Battery Lifespan: 5 years Range: 70M, 230Ft Min. (depending your home's construction) Communication Protocol: Proprietary 868MHz Operating Temperature: 32 to 104°F, 0 to 40°C (indoor only) Smart Button Pairing Button Press to pair Pairing Button Press to pair Smoke Detector Magnet Pairing Button Main Part Motion Sensor 3. AddSmart Sensor Gateway 4. AddSensors Make sure your smartphone or tablet is connected to the Wi-Fi. Tap Add new device below the app page and select Smart Sense, then follow the prompts to configure your device. Put finger on the Touch button of the Smart Sensor Gateway or tap Add New Sensor in the Smart Sense page to start the pairing, then use a needle to press the paring button on the sensor, an voice prompt "The sensor is paired" and the gateway indicator stays blue will indicate the pairing successful. Door Sensor Reset Button Press to stop the alarm Smoke Detector Smart Button Smart Button 9V 1. Open back cover Motion Sensor 1. Open back cover 2. Take off the insulating spacer Android: more than 800x480 resolution, Android 4.3+; iOS: iOS8.0+ 1. Open the back cover 2. Load the 6LR61 9V battery 3. Close back cover 4. Mount on ceiling 2. Mount the bracket, Scew on 5m 120° Door Sensor 5m 5m Smoke Detector 9V 2. Plug into the power outlet 1. Load battery with 2pcs AA 2. Take off the insulating spacer 3. Colse back cover 5m 120° 3. Colse back cover 4. Less than 22mm For technical support please visit:www.revogi.com/support Or email:support@revogi.com FCC Part 15.19 Warning Statement THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES. OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS: (1) THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE, AND (2) THIS DEVICE MUST ACCEPT ANY INTERFERENCE RECEIVED, INCLUDING INTERFERENCE THAT MAY CAUSE UNDESIRED OPERATION. FCC Part 15.21 Warning Statement NOTE: THE GRANTEE IS NOT RESPONSIBLE FOR ANY CHANGES OR MODIFICATIONS NOT EXPRESSLY APPROVED BY THE PARTY RESPONSIBLE FOR COMPLIANCE. SUCH MODIFICATIONS COULD VOID THE USER’S AUTHORITY TO OPERATE THE EQUIPMENT. FCC Part 15.105 Warning Statement Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: —Reorient or relocate the receiving antenna. —Increase the separation between the equipment and receiver. —Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. —Consult the dealer or an experienced radio/TV technician for help. RF warning statement: The device has been evaluated to meet general RF exposure requirement. To maintain compliance with FCC's RF exposure guidelines, this equipment should be installed and operated with a minimum distance of 20cm between the radiator and your body.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : No Has XFA : No XMP Toolkit : Adobe XMP Core 5.4-c005 78.147326, 2012/08/23-13:03:03 Format : application/pdf Creator : design Title : 未命名 -2 Create Date : 2016:11:29 14:24:55+08:00 Creator Tool : CorelDRAW X6 Modify Date : 2017:01:06 19:47:06+08:00 Metadata Date : 2017:01:06 19:47:06+08:00 Producer : Corel PDF Engine Version 16.1.0.843 Document ID : uuid:15139b49-fdce-49e2-992f-10408e8edbef Instance ID : uuid:b605840c-b6e8-4b86-987b-3528ce607557 Page Count : 2 Profile CMM Type : Lino Profile Version : 2.1.0 Profile Class : Display Device Profile Color Space Data : RGB Profile Connection Space : XYZ Profile Date Time : 1998:02:09 06:49:00 Profile File Signature : acsp Primary Platform : Microsoft Corporation CMM Flags : Not Embedded, Independent Device Manufacturer : IEC Device Model : sRGB Device Attributes : Reflective, Glossy, Positive, Color Rendering Intent : Perceptual Connection Space Illuminant : 0.9642 1 0.82491 Profile Creator : HP Profile ID : 0 Profile Copyright : Copyright (c) 1998 Hewlett-Packard Company Profile Description : sRGB IEC61966-2.1 Media White Point : 0.95045 1 1.08905 Media Black Point : 0 0 0 Red Matrix Column : 0.43607 0.22249 0.01392 Green Matrix Column : 0.38515 0.71687 0.09708 Blue Matrix Column : 0.14307 0.06061 0.7141 Device Mfg Desc : IEC http://www.iec.ch Device Model Desc : IEC 61966-2.1 Default RGB colour space - sRGB Viewing Cond Desc : Reference Viewing Condition in IEC61966-2.1 Viewing Cond Illuminant : 19.6445 20.3718 16.8089 Viewing Cond Surround : 3.92889 4.07439 3.36179 Viewing Cond Illuminant Type : D50 Luminance : 76.03647 80 87.12462 Measurement Observer : CIE 1931 Measurement Backing : 0 0 0 Measurement Geometry : Unknown Measurement Flare : 0.999% Measurement Illuminant : D65 Technology : Cathode Ray Tube Display Red Tone Reproduction Curve : (Binary data 2060 bytes, use -b option to extract) Green Tone Reproduction Curve : (Binary data 2060 bytes, use -b option to extract) Blue Tone Reproduction Curve : (Binary data 2060 bytes, use -b option to extract) Author : designEXIF Metadata provided by EXIF.tools