Rheem Cased And Uncased Gas Oil Furnace Applications Specification Sheet
2015-04-02
: Rheem Rheem-Cased-And-Uncased-Gas-And-Oil-Furnace-Applications-Specification-Sheet-683971 rheem-cased-and-uncased-gas-and-oil-furnace-applications-specification-sheet-683971 rheem pdf
Open the PDF directly: View PDF
.
Page Count: 8
| Download | |
| Open PDF In Browser | View PDF |
Air Indoor Coils RCFP Series Cased/Uncased Coils For Gas And Oil Furnaces RCFP- Series featuring Industry Standard R-410A Refrigerant Airflow Capacity 600-1,600 CFM [283-755 L/s] • Rheem® Indoor Coils are designed for use with Rheem outdoor units and are available for vertical upflow or downflow, and horizontal left or horizontal right airflow. When matched with Rheem outdoor units, the coils provide a nominal capacity range from 18,000 BTU/HR [5.24 kW] to 48,000 BTU/HR [14.06 kW]. • Constructed of aluminum fins bonded to internally grooved copper tubing. • Tin plated copper tubing in the finned area for superior corrosion resistance in harsh environments. • Coils are tested at the factory with an extensive refrigerant leak check. • Coils have sweat refrigerant connections. • Ideally suited for new installations or add on air conditioning. • Feature two sets of 3/4" [14.1 mm] N.P.T. Condensate drain connections for ease of connection. • Coils are AHRI certified for system application with variety of Rheem outdoor units. • Condensate drain pan is constructed of high grade, heat resistant, corrosion free thermal-set material. • Compatible with Germicidal Light System (UV resistant) • Bi-Directional airflow eliminates the need to switch any internal components from horizontal left to right. • Unique drain pan design maximizes application flexibility and condensate removal. • Universal Duct Flanges are included with all coil models. FORM NO. C11-222 REV. 1 Air Table of Contents RCFP Series TABLE OF CONTENTS Model Number Identification ............................................................................3 Coil Specifications ..........................................................................................3 Coil Dimensions and Weights ..........................................................................4 Accessories ................................................................................................5-6 2 Air Model I.D./Coil Specifications RCFP Series Model Number Identification R C F P — HM 24 14 A C Gas/Oil Furnace Coil C = Cased U = Uncased Available Models of RCFP Coils Design Variation A = 1st Design B = 2nd Design C = 3rd Design T = Tin plated copper tubing in finned area Coil Size 14 = 14" [356 mm] 17 = 17.5" [431.8 mm] 21 = 21" [533.4 mm] RCFP-HM2417CC RCFP-HU3621CU RCFP-HM3617CC RCFP-HU4824CU RCFP-HM4821CC RCFP-HU2417TU RCFP-HM3621CC RCFP-HU3617TU RCFP-HM4824CC RCFP-HU4821TU RCFP-HU2417CU RCFP-HU3621TU RCFP-HU3617CU RCFP-HU4824TU RCFP-HU4821CU Nominal Capacity 24 = 18,000 to 24,000 BTU/HR [5.27 to 7.03 kW] 36 = 30,000 to 36,000 BTU/HR [8.79 to 10.55 kW] 48 = 42,000 to 48,000 BTU/HR [12.31 to 14.06 kW] Cased Coil Airflow: HM = A/C or Heat Pump, Multi-Position Uncased Coil Airflow: HU = A/C or Heat Pump, Upflow/Downflow Refrigerant/Metering Device P = R-410A/Fixed Orifice F = Product Generation Classification C = Coil Rheem Table 1: Coil Specifications/Airflow Pressure Drop Coil Model RCFP Approx. Design Air Flow CFM [L/s] Range Face Area Sq. Ft. [m2] Fins-in. Rows Deep Static Pressure Drop Through Wet Cooling Coil [kPa] (Inches W.C.) CFM [L/s] 600 [285] 700 [330] 800 [380] 900 [425] 1000 [470] 1100 [519] 16/2 .15 [.039] .19 [.049] 16/2 — — 16/2 — — .23 [.059] .17 [.043] .15 [.038] .30 [.076] .21 [.053] .18 [.047] .38 [.096] .26 [.064] .23 [.058] .45 [.113] .31 [.080] .27 [.069] 16/2 — — — — — — 16/2 — — — — — — 1200 [565] 1300 [614] 1400 [660] 1500 [708] 1600 [755] 1700 [802] 1800 [850] 1900 [897] — — — — — — — — .36 [.092] .31 [.080] .22 [.056] .22 [.056] .41 [.103] .37 [.094] .25 [.063] .25 [.063] — — — — — — — — — — — — .28 [.071] .28 [.071] .32 [.081] .32 [.081] .36 [.092] .32 [.081] .41 [.103] .41 [.103] — — — — HIGH EFFICIENCY COOLING COILS 2417 3617 3621 4821 4824 600/1000 [283/472] 900/1400 [424/661] 900/1400 [424/661] 1200/1800 [566/850] 1200/1800 [566/850] 4.56 [0.42] 5.70 [0.53] 5.70 [0.53] 8.55 [0.79] 8.55 [0.79] NOTE: Represents Coil-Only Airflow Ratings [ ] Designates Metric Conversions 3 Air Coil Dimensions and Weights RCFP Series Table 2: Coil Dimensions and Weights Coil Model RCFP Connections Sweat (in.) [mm] Cased Coil Dimensions (in) [mm] Weight Liquid Suction I.D. 3/4 [19.05] A B C Coil Weight (lbs.) [Kg.] Shipping Weight (lbs.) [Kg.] 171/2 [445] 141/2 [368] 20 1/2 [508] 46 [21] 51 [23] 3617 I.D. 3/8 [9.53] 3/8 [9.53] 3/4 [19.05] 171/2 [445] 177/8 [454] 20 1/2 [508] 52 [24] 57 [26] 3621 3/8 [9.53] 3/4 [19.05] 21 1/2[533] 171/2 [445] 20 1/2 [508] 54 [24] 60 [27] 4821 4824 3/8 [9.53] 7/8 [22.23] 21 1/2[533] 257/8 [657] 28 1/2 [711] 76 [34] 83 [38] 3/8 [9.53] 7/8 [22.23] 241/2 [622] 253/8 [645] 32 1/2 [812] 89 [40] 99 [45] 2417 FIGURE 1: DIMENSIONS A MINUS ONE INCH ➀ 197/8 [505 mm] PLENUM WIDTH FRONT VIEW NOTE: FLANGES ARE PROVIDED FOR FIELD INSTALLATION SIDE VIEW 1/2 [12.7 mm] 17/16 [36.5 mm] SUCTION LINE 7/16 LIQUID LINE [11.1 mm] 515/16 [150.8 mm] 53/8 [136.5 mm] PRIMARY DRAIN 3/4 N.P.T. (VERTICAL & HORIZONTAL) 4 113/16 [46 mm] 11/4 [31.7 mm] 41/8 [104.7 mm] 2111/16 [550.8 mm] 21/4 [57.1 mm] SECONDARY DRAIN 3/4 N.P.T. (VERTICAL) PRIMARY DRAIN 3/4 N.P.T. (VERTICAL) ➀ Casing top and bottom openings are the same dimensions. [ ] Designates Metric Conversions Air Accessories RCFP Series Table 3: Coil Application Coils can be matched to heating products as listed in table below. Furnace Width (In.) (mm) Coil Model RCFP Oil 2417 3617 Gas — 2417 3617 21 3621 4821 21 4824 14 [356] 171/2 [444] [533] [533] 14 [356] 21 [533] 171/2 [444] 241/2 [622] 241/2 [622] 21 [533] *Note: Due to the proximity of the drain pan to the high temperature oil furnace drain, horizontal left application is not permitted on all oil furnaces. Accessories • INDOOR COIL CASING- RXBC (See Table 5) • PLENUM ADAPTER ACCESSORY RXBA-AE This plenum adapter accessory is for use with the 241/2" wide cased indoor cooling and heat pump coils. This allows a 241/2" wide cased coil to be installed on a 28" wide oil furnace. This is a field-installed accessory only. R X B C — D 14 I INSULATION I = Insulated Blank = Uninsulated CABINET WIDTH 14 = 14" [356 mm] 17 = 17.5" [444 mm] 21 = 21" [533 mm] 24 = 24.5" [622 mm] • RXBA-AC (Upflow/Horizontal) These plenum adapter accessories are for use when a cooling coil is matched with a gas furnace of one smaller size. DESIGN SERIES COIL CASING • HORIZONTAL ADAPTER KIT RXHH (See Figure 2) This horizontal adapter kit is used to convert a upflow or downflow coil for a horizontal application. See Table 4 to order the proper horizontal adapter kit. BLOWER UNIT ACCESSORY RHEEM *Note: The horizontal adapter kit cannot be used for RCFP-AU****BC applications. It can only be used on RCFP-AU****AC applications and for RCFP-HU****AC applications. Table 5: Unit Dimensions and Weights- RXBC Indoor Coil Casings Table 4: Horizontal Adapter Kit Model No. Coil Model 2414 2417 3617/3621 4821/4824 Horizontal Adapter Kit Model No. RXHH-A01 RXHH-A02 RXHH-A03 RXHH-A04 FIGURE 2: HORIZONTAL ADAPTER KIT ILLUSTRATION Model Number Depth Width Height (in.) (in.) [mm] (in.) [mm] [mm] Supply Air/Return Air Openings Unit Weight Weight Ship. Wt. Width (lbs.) [Kg.] (lbs.) [Kg.] (in.) [mm] Depth (in.) [mm] RXBC-D14AI 14 [356] 233/16 [589] 19 [9] 23 [10] 13 [330] RXBC-D17AI 171/2 [445] 20 [508] 18 [8] 23 [10] 161/2 [419] 215/8 RXBC-D21AI 21 [533] 20 [508] [549] RXBC-D21BI 21 [533] 28 [711] RXBC-D24AI 241/2 [622] 321/2 [826] 20 [9] 27 [12] 34 [16] 26 [12] 36 [17] 44 [20] 1931/32 20 [508] [508] 20 [508] 231/2 [597] Table 6: Uncased Coil Adapter Kit AIR FLOW HORIZONTAL-DUAL DIRECTION Uncased Coil Adapter Model Number RXBA A Width (in.) [mm] Uncased Coil Model RCFP B14x20 B17x20 131/8 [333] 165/8 [422] -HUxx14 -HUxx17 B21x20 B24x20 201/8 [511] 235/8 [599] -HUxx21 -HUxx24 [ ] Designates Metric Conversions HORIZONTAL ADAPTER KIT (RXHH-) 5 Air Accessories RCFP Series Accessories (cont.) • UNCASED COIL ADAPTER KIT RXBA- (See Figure 3 & 4) This uncased coil adapter kit is used to adapt the coil to a furnace or ductwork. See Table 6 to order the proper adapter kit. Each kit contains a quantity of 20 adapters. FIGURE 3: UNCASED COIL ADAPTER KIT ILLUSTRATION FIGURE 4: UNCASED COIL ADAPTER KIT ASSEMBLED 11/2 [41 mm] 711/16 [196 mm] A 205/16 [516 mm] Note: Sliding the coil into the coil rail before attaching coil rack front. [ ] Designates Metric Conversions 6 Air Notes RCFP Series 7 The new degree of comfort.™ In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice. Rheem Heating, Cooling & Water Heating • P.O. Box 17010 Fort Smith, Arkansas 72917 • www.rheem.com Rheem Canada Ltd./Ltée • 125 Edgeware Road, Unit 1 Brampton, Ontario • L6Y 0P5 PRINTED IN U.S.A 1/13 QG FORM NO. C11-222 REV. 1
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes XMP Toolkit : 3.1-701 Producer : Acrobat Distiller 10.0.0 (Macintosh) Create Date : 2013:01:03 15:53:34-06:00 Modify Date : 2013:01:18 18:02:49-06:00 Title : untitled Has XFA : No Page Count : 8EXIF Metadata provided by EXIF.tools