Rheem Classic Series Package Heat Pump Specification Sheet
Rheem-Classic-Series-Package-Heat-Pump-Specification-Sheet-684024 rheem-classic-series-package-heat-pump-specification-sheet-684024
2015-04-02
: Rheem Rheem-Classic-Series-Package-Heat-Pump-Specification-Sheet-684027 rheem-classic-series-package-heat-pump-specification-sheet-684027 rheem pdf
Open the PDF directly: View PDF .
Page Count: 52
Download | |
Open PDF In Browser | View PDF |
Air Package Heat Pump RQNL/RQPL Series Rheem Commercial Classic® Series Package Heat Pump RQNL- High Efficiency 13-SEER Series Nominal Sizes 2-4 Tons [7.03-14.07 kW] RQPL- High Efficiency 14-SEER Series Nominal Sizes 2-4 Tons [7.03-14.07 kW] (14 SEER ONLY) “Proper sizing and installation of equipment is critical to achieve optimal performance. Ask your Contractor for details or visit www.energystar.gov.” FORM NO. P11-791 Air Table of Contents RQNL/RQPL Series TABLE OF CONTENTS Unit Features & Benefits ..................................................................................3-4 Model Number Identification ..............................................................................5 Options ............................................................................................................6 General Data RQNL- Series ..............................................................................................7-8 RQPL- Series ............................................................................................9-11 General Data Notes ..........................................................................................12 Gross Systems Performance Data RQNL- Series ..........................................................................................13-17 RQPL- Series ..........................................................................................18-23 Indoor Airflow Performance RQNL- Series ..........................................................................................24-25 RQPL- Series ..........................................................................................26-27 Electrical Data RQNL- Series................................................................................................28 RQPL- Series................................................................................................28 Electric Heater Kits......................................................................................29-31 Dimensional Data ........................................................................................32-33 Typical Installations ..........................................................................................34 Accessories ................................................................................................35-43 Wiring Diagrams ..........................................................................................44-48 Limited Warranty ..............................................................................................52 2 Air Unit Features & Benefits RQNL/RQPL Series Package Heat Pump Features: 5 (Not Shown) 4 3 Air Unit Features & Benefits RQNL/RQPL Series Features Below Correspond to Photos on Page 3 1. All models feature Scroll® compressors for maximum efficiency and quiet operation. This unit contains a special scroll compressor that is designed specifically to operate with R-410A Refrigerants and polyolester (POE) oils. The compressor is hermetically sealed and incorporates internal high temperature motor overload protection and durable insulation on the motor windings. It is externally mounted on rubber grommets to reduce vibration and noise. 2. Louvered condenser compartment for protecting the coil against yard hazards and/or weather extremes. 3. One-piece top with a deep flange to help keep water out of the unit. 4. Supply and return air openings feature a one-inch tall flange to prevent water migration into the ductwork. 5. Access panels have “weep holes” and channels to further help manage water run-off. 6. Side and down discharge options available on all models. (Shipped Downflow Standard). 9. Condenser and evaporator coils feature enhanced fins for better heat transfer and rifled copper tubing for greater efficiency. 10. Supplemental electric heat strips up to 15 kW are available (field or factory installed) for periods of extreme cold temperatures. Single point wiring makes installation even easier. 11. All units feature an internal trap on the condensate line eliminating the need for installing an on-site external trap. 12. Easily accessible control box. Package heat pump utilizes demand defrost control which monitors the outdoor ambient temperature, outdoor coil temperature, and compressor run-time to determine when a defrost cycle is required. 13. Thermal Expansion Valve standard on all models for superior superheat control, reliability, and energy efficiency at all operating conditions. 14. Filter Drier Standard on all models (not shown). 7. Easily accessible blower section complete with slideout blower. 15. Rugged Baserail for improved installation and handling. 8. Refrigerant connections are conveniently located for easy service diagnostics. Low pressure/loss of charge protection is standard on all models. 16. Reversing valve directs flow of refrigerant and reverses the refrigerant flow when heating is required. 4 Air Model Number Identification RQNL/RQPL Series R Q N L — B024 J K 000 X X X Factory Installed Options (See Next Page) Heating Capacity (Factory Installed) 000 = No Resistance Heat 005 = 05 KW Resistance Heat (018-030) 010 = 10 KW Resistance Heat (024-048) 015 = 15 KW Resistance Heat (036-048) Drive Package K = Direct Drive Electrical Designation J = 208-230V—1PH—60 Hz C = 208-230V—3PH—60 Hz Cooling Capacity (BTUH) [kW] B024 = 24,000 [7.03] B025 = 24,000 [7.03] B030 = 30,000 [8.79] B036 = 36,000 [10.55] B042 = 42,000 [12.31] B048 = 48,000 [14.07] Design Series L = R-410A Efficiency Designation N = 13 SEER High Efficiency P = 14 SEER High Efficiency Product Classification Q = Package Heat Pump Tradebrand R = Rheem [ ] Designates Metric Conversions 5 Air Options RQNL/RQPL Series Instructions for Factory Installed Option(s) Selection Note: Two characters following the model number will be utilized to designate a factory-installed option or combination of options. If no factory option(s) is required, nothing follows the model number. Step 1. After a basic rooftop model is selected, choose a two-character option code from the FACTORY INSTALLED OPTION SELECTION TABLE. FACTORY INSTALLED OPTION CODES Option Code AA AKA Example: RQNL-B036JK000XX (where XX is factory installed option) Example: No Options RQNL-B036JK000 Example: Options with Sideflow RQNL-B036JK000AKA Note: Factory installed economizer is not available on these models. 6 Side Flow No Option x General Data RQNL Series Air NOMINAL SIZES 2-4 TONS [7.03-14.07 kW] Model RQNL- Series Cooling Performance1 Gross Cooling Capacity Btu [kW] EER/SEER2 B024JK B030JK B036CK B036JK 24,400 [7.15] 11/13 29,000 [8.5] 11/13 36,200 [10.61] 11/13 CONTINUED 36,200 [10.61] 11/13 800/800 [378/378] 23,600 [6.91] 1000/1000 [472/472] 27,800 [8.15] 1200/1250 [566/590] 35,000 [10.26] 1200/1250 [566/590] 35,000 [10.26] 17,600 [5.16] 6,000 [1.76] 20,800 [6.09] 7,000 [2.05] 26,000 [7.62] 9,000 [2.64] 26,000 [7.62] 9,000 [2.64] 2.15 2.53 3.18 3.18 23,600 [6.91] 2.02/3.4 13,000 [3.81] 28,200 [8.26] 2.45/3.4 16,000 [4.69] 34,000 [9.96] 2.86/3.5 19,500 [5.71] 34,000 [9.96] 2.86/3.5 19,500 [5.71] 1.9/2 2.26/2.1 2.61/2.2 2.61/2.2 7.7 7.7 7.7 7.7 1/Scroll 76 1/Scroll 76 1/Scroll 76 1/Scroll 76 Louvered Louvered Louvered Louvered Rifled 0.375 [9.5] 14.51 [1.35] 1 / 22 [9] Rifled 0.375 [9.5] 16.32 [1.52] 1 / 22 [9] Rifled 0.375 [9.5] 11.2 [1.04] 2 / 22 [9] Rifled 0.375 [9.5] 11.2 [1.04] 2 / 22 [9] Refrigerant Control TX Valves TX Valves TX Valves TX Valves Indoor Coil—Fin Type Tube Type Tube Size in. [mm] Louvered Rifled 0.375 [9.5] Louvered Rifled 0.375 [9.5] Louvered Rifled 0.375 [9.5] Louvered Rifled 0.375 [9.5] 5.54 [0.51] 7.39 [0.69] 7.39 [0.69] 7.39 [0.69] 2 / 15 [6] TX Valves 1/1 [25.4] Propeller 2 / 15 [6] TX Valves 1/1 [25.4] Propeller 2 / 15 [6] TX Valves 1/1 [25.4] Propeller 2 / 15 [6] TX Valves 1/1 [25.4] Propeller 1/22 [558.8] 1/22 [558.8] 1/22 [558.8] 1/22 [558.8] Direct/1 Direct/1 Direct/1 Direct/1 CFM [L/s] 2700 [1274] 2700 [1274] 2700 [1274] 2700 [1274] No. Motors/HP 1 at 1/5 HP 1 at 1/5 HP 1 at 1/5 HP 1 at 1/5 HP 1075 1075 1075 1075 FC Centrifugal 1/9x7 [228.6x177.8] Direct/2 FC Centrifugal 1/10x9 [254x228.6] Direct/3 FC Centrifugal 1/10x9 [254x228.6] Direct/1 FC Centrifugal 1/10x9 [254x228.6] Direct/1 Nominal CFM/AHRI Rated CFM [L/s] AHRI Net Cooling Capacity Btu [kW] Net Sensible Capacity Btu [kW] Net Latent Capacity Btu [kW] Net System Power kW Heating Performance (Heat Pumps)4 Heating Input Btu [kW] Rating System Power KW/COP Low Temp. Btuh [kW] Rating System Power KW/COP HSPF (Btu/Watts-hr) Compressor No./Type Outdoor Sound Rating (dB)3 Outdoor Coil—Fin Type Tube Type Tube Size in. [mm] OD Face Area sq. ft. [sq. m] Rows / FPI [FPcm] Face Area sq. ft. [sq. m] Rows / FPI [FPcm] Refrigerant Control Drain Connection No./Size in. [mm] Outdoor Fan—Type No. Used/Diameter in. [mm] Drive Type/No. Speeds Motor RPM Indoor Fan—Type No. Used/Diameter in. [mm] Drive Type/No. Speeds No. Motors Motor HP Motor RPM Motor Frame Size Filter—Type Furnished 1 1 1 1 1/4 1/2 1/3 1/3 1075 1075 1075 1075 48 Field Supplied 48 Field Supplied 48 Field Supplied 48 Field Supplied No No No No (1)1x20x20 [25x508x508] (1)1x24x24 [25x610x610] (1)1x24x24 [25x610x610] (1)1x24x24 [25x610x610] Refrigerant Charge Oz. [g] 98 [2778] 108 [3062] 146 [4139] 146 [4139] Weights Net Weight lbs. [kg] 391 [177] 444 [201] 471 [214] 468 [212] 401 [182] 455 [206] 482 [219] 479 [217] (No.) Size Recommended in. [mm] Ship Weight lbs. [kg] See Page 12 for Notes. [ ] Designates Metric Conversions 7 Air General Data RQNL Series NOMINAL SIZES 2-4 TONS [7.03-14.07 kW] Model RQNL- Series B042CK B042JK B048CK B048JK 43,500 [12.75] 11/13 43,500 [12.75] 11/13 49,000 [14.36] 11/13 49,000 [14.36] 11/13 1400/1400 [661/661] 42,500 [12.45] 1400/1400 [661/661] 42,500 [12.45] 1600/1600 [755/755] 47,500 [13.92] 1600/1600 [755/755] 47,500 [13.92] 31,500 [9.23] 11,000 [3.22] 31,500 [9.23] 11,000 [3.22] 36,000 [10.55] 11,500 [3.37] 36,000 [10.55] 11,500 [3.37] 3.86 3.86 4.31 4.31 41,500 [12.16] 3.65/3.4 24,200 [7.09] 41,500 [12.16] 3.65/3.4 24,200 [7.09] 46,000 [13.48] 3.89/3.4 26,600 [7.79] 46,000 [13.48] 3.89/3.4 26,600 [7.79] 3.43/2.08 3.43/2.08 3.57/2.2 3.57/2.2 7.7 7.7 7.7 7.7 1/Scroll 76 1/Scroll 76 1/Scroll 78 1/Scroll 78 Louvered Louvered Louvered Louvered Rifled 0.375 [9.5] 16.32 [1.52] 2 / 22 [9] Rifled 0.375 [9.5] 16.32 [1.52] 2 / 22 [9] Rifled 0.375 [9.5] 16.32 [1.52] 2 / 22 [9] Rifled 0.375 [9.5] 16.32 [1.52] 2 / 22 [9] Refrigerant Control TX Valves TX Valves TX Valves TX Valves Indoor Coil—Fin Type Tube Type Tube Size in. [mm] Louvered Rifled 0.375 [9.5] Louvered Rifled 0.375 [9.5] Louvered Rifled 0.375 [9.5] Louvered Rifled 0.375 [9.5] 7.39 [0.69] 7.39 [0.69] 7.39 [0.69] 7.39 [0.69] 2 / 15 [6] TX Valves 1/1 [25.4] Propeller 2 / 15 [6] TX Valves 1/1 [25.4] Propeller 2 / 15 [6] TX Valves 1/1 [25.4] Propeller 2 / 15 [6] TX Valves 1/1 [25.4] Propeller 1/22 [558.8] 1/22 [558.8] 1/22 [558.8] 1/22 [558.8] Direct/1 Direct/1 Direct/1 Direct/1 CFM [L/s] 3300 [1557] 3300 [1557] 3000 [1416] 3000 [1416] No. Motors/HP 1 at 1/3 HP 1 at 1/3 HP 1 at 1/3 HP 1 at 1/3 HP 1075 1075 1075 1075 FC Centrifugal 1/10x9 [254x228.6] Direct/2 FC Centrifugal 1/10x9 [254x228.6] Direct/2 FC Centrifugal 1/10x9 [254x228.6] Direct/2 FC Centrifugal 1/10x9 [254x228.6] Direct/2 Cooling Performance1 Gross Cooling Capacity Btu [kW] EER/SEER2 Nominal CFM/AHRI Rated CFM [L/s] AHRI Net Cooling Capacity Btu [kW] Net Sensible Capacity Btu [kW] Net Latent Capacity Btu [kW] Net System Power kW Heating Performance (Heat Pumps)4 Heating Input Btu [kW] Rating System Power KW/COP Low Temp. Btuh [kW] Rating System Power KW/COP HSPF (Btu/Watts-hr) Compressor No./Type Outdoor Sound Rating (dB)3 Outdoor Coil—Fin Type Tube Type Tube Size in. [mm] OD Face Area sq. ft. [sq. m] Rows / FPI [FPcm] Face Area sq. ft. [sq. m] Rows / FPI [FPcm] Refrigerant Control Drain Connection No./Size in. [mm] Outdoor Fan—Type No. Used/Diameter in. [mm] Drive Type/No. Speeds Motor RPM Indoor Fan—Type No. Used/Diameter in. [mm] Drive Type/No. Speeds No. Motors Motor HP Motor RPM Motor Frame Size Filter—Type Furnished 1 1 1 1 3/4 3/4 3/4 3/4 1075 1075 1075 1075 48 Field Supplied 48 Field Supplied 48 Field Supplied 48 Field Supplied No No No No (1)1x24x24 [25x610x610] (1)1x24x24 [25x610x610] (1)1x24x24 [25x610x610] (1)1x24x24 [25x610x610] Refrigerant Charge Oz. [g] 176 [4990] 176 [4990] 183 [5188] 183 [5188] Weights Net Weight lbs. [kg] 508 [230] 505 [229] 500 [227] 510 [231] 519 [235] 516 [234] 511 [232] 521 [236] (No.) Size Recommended in. [mm] Ship Weight lbs. [kg] See Page 12 for Notes. 8 [ ] Designates Metric Conversions General Data RQPL Series Air NOMINAL SIZES 2-4 TONS [7.03-14.07 kW] Model RQPL- Series Cooling Performance1 Gross Cooling Capacity Btu [kW] EER/SEER2 B024JK B025JK B030JK B036CK 25,000 [7.32] 11.8/14 24,400 [7.15] 12/14 29,800 [8.73] 12/14 CONTINUED 36,800 [10.78] 12/14 800/850 [378/401] 24,400 [7.15] 800/850 [378/401] 23,800 [6.97] 1000/1050 [472/495] 29,200 [8.56] 1200/1250 [566/590] 36,000 [10.55] 18,900 [5.54] 5,500 [1.61] 17,800 [5.22] 6,000 [1.76] 23,000 [6.74] 6,200 [1.82] 27,000 [7.91] 9,000 [2.64] 2.06 1.98 2.43 3 23,800 [6.97] 1.94/3.5 13,800 [4.04] 23,600 [6.91] 1.88/3.7 12,900 [3.78] 27,800 [8.15] 2.27/3.6 15,500 [4.54] 33,200 [9.73] 2.73/3.6 18,000 [5.27] 1.78/2.2 1.7/2.24 2.07/2.2 2.5/2.2 8 8 8 8 1/Scroll 76 1/Scroll 76 1/Scroll 76 1/Scroll 76 Louvered Louvered Louvered Louvered Rifled 0.375 [9.5] 14.51 [1.35] 1 / 22 [9] Rifled 0.375 [9.5] 14.51 [1.35] 1 / 22 [9] Rifled 0.375 [9.5] 16.32 [1.52] 1 / 22 [9] Rifled 0.375 [9.5] 11.2 [1.04] 2 / 22 [9] Refrigerant Control TX Valves TX Valves TX Valves TX Valves Indoor Coil—Fin Type Tube Type Tube Size in. [mm] Louvered Rifled 0.375 [9.5] Louvered Rifled 0.375 [9.5] Louvered Rifled 0.375 [9.5] Louvered Rifled 0.375 [9.5] 5.54 [0.51] 5.54 [0.51] 7.39 [0.69] 7.39 [0.69] 2 / 15 [6] TX Valves 1/1 [25.4] Propeller 2 / 15 [6] TX Valves 1/1 [25.4] Propeller 2 / 15 [6] TX Valves 1/1 [25.4] Propeller 2 / 15 [6] TX Valves 1/1 [25.4] Propeller 1/22 [558.8] 1/22 [558.8] 1/22 [558.8] 1/22 [558.8] Direct/1 Direct/1 Direct/1 Direct/1 CFM [L/s] 2700 [1274] 2700 [1274] 2700 [1274] 2700 [1274] No. Motors/HP 1 at 1/5 HP 1 at 1/3 HP 1 at 1/5 HP 1 at 1/5 HP 1075 869 1075 1075 FC Centrifugal 1/9x7 [228.6x177.8] Direct/2 FC Centrifugal 1/9x7 [229x178] Direct/2 FC Centrifugal 1/10x9 [254x228.6] Direct/3 FC Centrifugal 1/10x9 [254x228.6] Direct/3 Nominal CFM/AHRI Rated CFM [L/s] AHRI Net Cooling Capacity Btu [kW] Net Sensible Capacity Btu [kW] Net Latent Capacity Btu [kW] Net System Power kW Heating Performance (Heat Pumps)4 Heating Input Btu [kW] Rating System Power KW/COP Low Temp. Btuh [kW] Rating System Power KW/COP HSPF (Btu/Watts-hr) Compressor No./Type Outdoor Sound Rating (dB)3 Outdoor Coil—Fin Type Tube Type Tube Size in. [mm] OD Face Area sq. ft. [sq. m] Rows / FPI [FPcm] Face Area sq. ft. [sq. m] Rows / FPI [FPcm] Refrigerant Control Drain Connection No./Size in. [mm] Outdoor Fan—Type No. Used/Diameter in. [mm] Drive Type/No. Speeds Motor RPM Indoor Fan—Type No. Used/Diameter in. [mm] Drive Type/No. Speeds No. Motors Motor HP Motor RPM Motor Frame Size Filter—Type Furnished 1 1 1 1 1/3 1/3 1/2 1/2 1050 1050 1050 1075 48 Field Supplied 48 Field Supplied 48 Field Supplied 48 Field Supplied No No No No (1)1x20x20 [25x508x508] (1)1x20x20 [25x508x508] (1)1x24x24 [25x610x610] (1)1x24x24 [25x610x610] Refrigerant Charge Oz. [g] 98 [2778] 98 [2778] 108 [3062] 146 [4139] Weights Net Weight lbs. [kg] 391 [177] 391 [177] 444 [201] 471 [214] 401 [182] 401 [182] 455 [206] 482 [219] (No.) Size Recommended in. [mm] Ship Weight lbs. [kg] See Page 12 for Notes. [ ] Designates Metric Conversions 9 Air General Data RQPL Series NOMINAL SIZES 2-4 TONS [7.03-14.07 kW] Model RQPL- Series Cooling Performance1 Gross Cooling Capacity Btu [kW] EER/SEER2 Nominal CFM/AHRI Rated CFM [L/s] AHRI Net Cooling Capacity Btu [kW] Net Sensible Capacity Btu [kW] Net Latent Capacity Btu [kW] Net System Power kW Heating Performance (Heat Pumps)4 Heating Input Btu [kW] Rating System Power KW/COP Low Temp. Btuh [kW] Rating System Power KW/COP HSPF (Btu/Watts-hr) B036JK B042CK B042JK B048CK 36,800 [10.78] 12/14 43,500 [12.75] 11.3/14 43,500 [12.75] 11.3/14 CONTINUED 49,000 [14.36] 11.5/14 1200/1250 [566/590] 36,000 [10.55] 1400/1400 [661/661] 42,500 [12.45] 1400/1400 [661/661] 42,500 [12.45] 1600/1600 [755/755] 47,500 [13.92] 27,000 [7.91] 9,000 [2.64] 31,500 [9.23] 11,000 [3.22] 31,500 [9.23] 11,000 [3.22] 36,000 [10.55] 11,500 [3.37] 3 3.85 3.85 4.26 33,200 [9.73] 2.73/3.6 18,000 [5.27] 41,500 [12.16] 3.65/3.4 24,200 [7.09] 41,500 [12.16] 3.65/3.4 24,200 [7.09] 46,000 [13.48] 3.89/3.45 26,600 [7.79] 2.5/2.2 3.43/2.08 3.43/2.08 3.57/2.2 8 8 8 8 1/Scroll 76 1/Scroll 76 1/Scroll 76 1/Scroll 78 Compressor No./Type Outdoor Sound Rating (dB)3 Outdoor Coil—Fin Type Louvered Louvered Louvered Louvered Tube Type Tube Size in. [mm] OD Face Area sq. ft. [sq. m] Rows / FPI [FPcm] Rifled 0.375 [9.5] 11.2 [1.04] 2 / 22 [9] Rifled 0.375 [9.5] 16.32 [1.52] 2 / 22 [9] Rifled 0.375 [9.5] 16.32 [1.52] 2 / 22 [9] Rifled 0.375 [9.5] 16.32 [1.52] 2 / 22 [9] Refrigerant Control TX Valves TX Valves TX Valves TX Valves Indoor Coil—Fin Type Tube Type Tube Size in. [mm] Louvered Rifled 0.375 [9.5] Louvered Rifled 0.375 [9.5] Louvered Rifled 0.375 [9.5] Louvered Rifled 0.375 [9.5] 7.39 [0.69] 7.39 [0.69] 7.39 [0.69] 7.39 [0.69] 2 / 15 [6] TX Valves 1/1 [25.4] Propeller 2 / 15 [6] TX Valves 1/1 [25.4] Propeller 2 / 15 [6] TX Valves 1/1 [25.4] Propeller 2 / 15 [6] TX Valves 1/1 [25.4] Propeller 1/22 [558.8] 1/22 [558.8] 1/22 [558.8] 1/22 [558.8] Direct/1 Direct/1 Direct/1 Direct/1 CFM [L/s] 2700 [1274] 3300 [1557] 3300 [1557] 3000 [1416] No. Motors/HP 1 at 1/5 HP 1 at 1/3 HP 1 at 1/3 HP 1 at 1/3 HP 1075 1075 1075 1075 FC Centrifugal 1/10x9 [254x228.6] Direct/3 FC Centrifugal 1/10x9 [254x228.6] Direct/2 FC Centrifugal 1/10x9 [254x228.6] Direct/2 FC Centrifugal 1/10x9 [254x228.6] Direct/2 Face Area sq. ft. [sq. m] Rows / FPI [FPcm] Refrigerant Control Drain Connection No./Size in. [mm] Outdoor Fan—Type No. Used/Diameter in. [mm] Drive Type/No. Speeds Motor RPM Indoor Fan—Type No. Used/Diameter in. [mm] Drive Type/No. Speeds No. Motors Motor HP Motor RPM Motor Frame Size Filter—Type Furnished 1 1 1 1 1/2 3/4 3/4 3/4 1050 1075 1075 1075 48 Field Supplied 48 Field Supplied 48 Field Supplied 48 Field Supplied No No No No (1)1x24x24 [25x610x610] (1)1x24x24 [25x610x610] (1)1x24x24 [25x610x610] (1)1x24x24 [25x610x610] Refrigerant Charge Oz. [g] 146 [4139] 176 [4990] 176 [4990] 183 [5188] Weights Net Weight lbs. [kg] 468 [212] 508 [230] 505 [229] 500 [227] 479 [217] 519 [235] 516 [234] 511 [232] (No.) Size Recommended in. [mm] Ship Weight lbs. [kg] See Page 12 for Notes. 10 [ ] Designates Metric Conversions Air General Data RQPL Series NOMINAL SIZES 2-4 TONS [7.03-14.07 kW] Model RQPL- Series Cooling Performance1 Gross Cooling Capacity Btu [kW] EER/SEER2 Nominal CFM/AHRI Rated CFM [L/s] AHRI Net Cooling Capacity Btu [kW] Net Sensible Capacity Btu [kW] Net Latent Capacity Btu [kW] Net System Power kW Heating Performance (Heat Pumps)4 Heating Input Btu [kW] Rating System Power KW/COP Low Temp. Btuh [kW] Rating System Power KW/COP HSPF (Btu/Watts-hr) B048JK 49,000 [14.36] 11.5/14 1600/1600 [755/755] 47,500 [13.92] 36,000 [10.55] 11,500 [3.37] 4.26 46,000 [13.48] 3.89/3.45 26,600 [7.79] 3.57/2.2 8 Compressor No./Type Outdoor Sound Rating (dB)3 Outdoor Coil—Fin Type Tube Type Tube Size in. [mm] OD Face Area sq. ft. [sq. m] Rows / FPI [FPcm] 1/Scroll 78 Louvered Rifled 0.375 [9.5] 16.32 [1.52] 2 / 22 [9] Refrigerant Control TX Valves Indoor Coil—Fin Type Tube Type Tube Size in. [mm] Louvered Rifled 0.375 [9.5] Face Area sq. ft. [sq. m] Rows / FPI [FPcm] Refrigerant Control Drain Connection No./Size in. [mm] Outdoor Fan—Type No. Used/Diameter in. [mm] Drive Type/No. Speeds 7.39 [0.69] 2 / 15 [6] TX Valves 1/1 [25.4] Propeller 1/22 [558.8] Direct/1 CFM [L/s] 3000 [1416] No. Motors/HP 1 at 1/3 HP Motor RPM Indoor Fan—Type No. Used/Diameter in. [mm] Drive Type/No. Speeds No. Motors Motor HP Motor RPM Motor Frame Size Filter—Type Furnished (No.) Size Recommended in. [mm] 1075 FC Centrifugal 1/10x9 [254x228.6] Direct/2 1 3/4 1075 48 Field Supplied No (1)1x24x24 [25x610x610] Refrigerant Charge Oz. [g] 183 [5188] Weights Net Weight lbs. [kg] 510 [231] Ship Weight lbs. [kg] See Page 12 for Notes. 521 [236] [ ] Designates Metric Conversions 11 Air General Data Notes RQNL/RQPL Series NOTES: 1. Cooling Performance is rated at 95° F ambient, 80° F entering dry bulb, 67° F entering wet bulb. Gross capacity does not include the effect of fan motor heat. AHRI capacity is net and includes the effect of fan motor heat. Units are suitable for operation in CFM range shown in airflow tables. Units are certified in accordance with the Unitary Air Conditioner Equipment certification program, which is based on AHRI Standard 210/240 or 360. 2. EER and/or SEER are rated at AHRI conditions and in accordance with DOE test procedures. 3. Outdoor Sound Rating shown is tested in accordance with AHRI Standard 270. 4. Heating Performance is rated at 47° F ambient, 70° F entering dry bulb for High Temp rating and 17° F ambient, 70° F entering dry bulb for Low Temp rating. Performance ratings do include the effect of fan motor heat. 12 Air Gross Systems Performance Data RQNL Series COOLING PERFORMANCE DATA—RQNL-024 ENTERING INDOOR AIR @ 80°F [26.7°C] dbE ➀ wbE CFM [L/s] DR ➀ 880 [415] .17 71°F [21.7°C] 800 [378] .15 720 [340] .13 880 [415] .17 67°F [19.4°C] 800 [378] .15 720 [340] .13 880 [415] .17 63°F [17.2°C] 800 [378] .15 720 [340] .13 Total BTUH [kW] 75 Sens BTUH [kW] [23.9] Power 29.4 [8.62] 18.2 [5.33] 1.5 28.9 [8.47] 17.4 [5.10] 1.5 28.3 [8.29] 16.6 [4.86] 1.5 28.1 [8.24] 21.0 [6.15] 1.5 27.6 [8.09] 20.1 [5.89] 1.5 27.1 [7.94] 19.1 [5.60] 1.5 27.1 [7.94] 22.3 [6.54] 1.5 26.6 [7.80] 21.3 [6.24] 1.5 26.1 [7.65] 20.3 [5.95] 1.5 Total BTUH [kW] 80 Sens BTUH [kW] [26.7] Power 29.2 [8.56] 18.0 [5.28] 1.6 28.6 [8.38] 17.2 [5.04] 1.6 28.1 [8.24] 16.4 [4.81] 1.6 27.8 [8.15] 20.8 [6.10] 1.6 27.3 [8.00] 19.8 [5.80] 1.6 26.8 [7.85] 18.9 [5.54] 1.6 26.8 [7.85] 22.1 [6.48] 1.6 26.4 [7.74] 21.1 [6.18] 1.6 25.9 [7.59] 20.1 [5.89] 1.6 Total BTUH [kW] 85 Sens BTUH [kW] [29.4] Power 28.5 [8.35] 17.6 [5.16] 1.7 28.0 [8.21] 16.8 [4.92] 1.7 27.5 [8.06] 16.0 [4.69] 1.7 27.2 [7.97] 20.4 [5.98] 1.7 26.7 [7.83] 19.5 [5.71] 1.7 26.2 [7.68] 18.6 [5.45] 1.7 26.2 [7.68] 21.7 [6.36] 1.7 25.7 [7.53] 20.7 [6.07] 1.7 25.2 [7.39] 19.7 [5.77] 1.7 Total BTUH [kW] 90 Sens BTUH [kW] [32.2] Power Total BTUH [kW] 95 Sens BTUH [kW] [35] Power Total BTUH [kW] 100 Sens BTUH [kW] [37.8] Power 27.5 [8.06] 17.1 [5.01] 1.8 27.0 [7.91] 16.3 [4.78] 1.8 26.5 [7.77] 15.6 [4.57] 1.8 26.1 [7.65] 19.9 [5.83] 1.8 25.7 [7.53] 19.0 [5.57] 1.8 25.2 [7.39] 18.1 [5.30] 1.8 25.2 [7.39] 21.2 [6.21] 1.8 24.7 [7.24] 20.2 [5.92] 1.8 24.3 [7.12] 19.3 [5.66] 1.8 26.2 [7.68] 16.5 [4.84] 1.9 25.8 [7.56] 15.8 [4.63] 1.9 25.3 [7.41] 15.0 [4.40] 1.9 24.9 [7.30] 19.3 [5.66] 1.9 24.5 [7.18] 18.5 [5.42] 1.9 24.0 [7.03] 17.6 [5.16] 1.9 23.9 [7.00] 20.6 [6.04] 1.9 23.5 [6.89] 19.7 [5.77] 1.9 23.1 [6.77] 18.8 [5.51] 1.9 24.9 [7.30] 15.9 [4.66] 2.0 24.4 [7.15] 15.2 [4.45] 2.0 24.0 [7.03] 14.5 [4.25] 2.0 23.5 [6.89] 18.7 [5.48] 2.0 23.1 [6.77] 17.9 [5.25] 2.0 22.7 [6.65] 17.0 [4.98] 2.0 22.5 [6.59] 20.0 [5.86] 2.0 22.1 [6.48] 19.1 [5.60] 2.0 21.7 [6.36] 18.2 [5.33] 2.0 Total BTUH [kW] 105 Sens BTUH [kW] [40.6] Power 23.5 [6.89] 15.2 [4.45] 2.1 23.1 [6.77] 14.5 [4.25] 2.1 22.7 [6.65] 13.9 [4.07] 2.1 22.2 [6.51] 18.0 [5.28] 2.1 21.8 [6.39] 17.2 [5.04] 2.1 21.4 [6.27] 16.4 [4.81] 2.1 21.2 [6.21] 19.3 [5.66] 2.1 20.8 [6.10] 18.5 [5.42] 2.1 20.4 [5.98] 17.6 [5.16] 2.1 Total BTUH [kW] 110 Sens BTUH [kW] °F [43.3] Power [°C] Total BTUH [kW] 115 Sens BTUH [kW] [46.1] Power 22.2 [6.51] 14.6 [4.28] 2.2 21.1 [6.18] 14.0 [4.10] 2.3 21.8 [6.39] 14.0 [4.10] 2.2 20.7 [6.07] 13.4 [3.93] 2.3 21.4 [6.27] 13.3 [3.90] 2.2 20.3 [5.95] 12.8 [3.75] 2.3 20.9 [6.13] 17.4 [5.10] 2.2 19.8 [5.80] 16.9 [4.95] 2.3 20.5 [6.01] 16.7 [4.89] 2.2 19.4 [5.69] 16.1 [4.72] 2.3 20.1 [5.89] 15.9 [4.66] 2.2 19.0 [5.57] 15.4 [4.51] 2.3 19.9 [5.83] 18.7 [5.48] 2.2 18.8 [5.51] 18.1 [5.30] 2.3 19.5 [5.71] 17.9 [5.25] 2.2 18.4 [5.39] 17.3 [5.07] 2.3 19.2 [5.63] 17.0 [4.98] 2.2 18.1 [5.30] 16.5 [4.84] 2.3 O U T D O O R D R Y B U L B T E M P E R A T U R E DR —Depression ratio dbE —Entering air dry bulb wbE —Entering air wet bulb Total —Total capacity x 1000 BTUH Sens —Sensible capacity x 1000 BTUH Power —KW input NOTES: ➀ When the entering air dry bulb is other than 80°F [27°C], adjust the sensible capacity from the table by adding [1.10 x CFM x (1 – DR) x (dbE – 80)]. HEATING PERFORMANCE DATA—RQNL-024 IDB CFM [L/s] O U T D O O R D R Y B U L B T E M P E R A T U R E °F [°C] 0 [-17.8] 5 [-15] 10 [-12.2] 15 [-9.4] 20 [-6.7] 25 [-3.9] 30 [-1.1] 35 [1.7] 40 [4.4] 45 [7.2] 50 [10] Total BTUH [kW] Power Total BTUH [kW] Power Total BTUH [kW] Power Total BTUH [kW] Power Total BTUH [kW] Power Total BTUH [kW] Power Total BTUH [kW] Power Total BTUH [kW] Power Total BTUH [kW] Power Total BTUH [kW] Power Total BTUH [kW] Power IDB—Indoor air dry bulb 880 [415] 60°F [15.5°C] 800 [378] 720 [340] 880 [415] 70°F [21.1°C] 800 [378] 720 [340] 880 [415] 80°F [26.7°C] 800 [378] 720 [340] 8.3 [2.43] 1.4 10.0 [2.93] 1.4 11.6 [3.40] 1.4 13.2 [3.87] 1.4 14.9 [4.37] 1.5 16.5 [4.84] 1.5 18.1 [5.30] 1.5 19.8 [5.80] 1.5 21.4 [6.27] 1.5 23.0 [6.74] 1.6 24.7 [7.24] 1.6 8.3 [2.43] 1.4 9.9 [2.90] 1.4 11.5 [3.37] 1.4 13.1 [3.84] 1.5 14.8 [4.34] 1.5 16.4 [4.81] 1.5 18.0 [5.28] 1.5 19.6 [5.74] 1.5 21.3 [6.24] 1.6 22.9 [6.71] 1.6 24.5 [7.18] 1.6 8.2 [2.40] 1.4 9.8 [2.87] 1.4 11.4 [3.34] 1.5 13.0 [3.81] 1.5 14.7 [4.31] 1.5 16.3 [4.78] 1.5 17.9 [5.25] 1.5 19.5 [5.71] 1.6 21.1 [6.18] 1.6 22.7 [6.65] 1.6 24.3 [7.12] 1.6 7.4 [2.17] 1.6 9.1 [2.67] 1.6 10.7 [3.14] 1.6 12.3 [3.60] 1.6 14.0 [4.10] 1.6 15.6 [4.57] 1.7 17.2 [5.04] 1.7 18.9 [5.54] 1.7 20.5 [6.01] 1.7 22.1 [6.48] 1.7 23.8 [6.98] 1.8 7.4 [2.17] 1.6 9.0 [2.64] 1.6 10.6 [3.11] 1.6 12.3 [3.60] 1.6 13.9 [4.07] 1.7 15.5 [4.54] 1.7 17.1 [5.01] 1.7 18.7 [5.48] 1.7 20.4 [5.98] 1.7 22.0 [6.45] 1.8 23.6 [6.92] 1.8 7.3 [2.14] 1.6 9.0 [2.64] 1.6 10.6 [3.11] 1.6 12.2 [3.58] 1.7 13.8 [4.04] 1.7 15.4 [4.51] 1.7 17.0 [4.98] 1.7 18.6 [5.45] 1.7 20.2 [5.92] 1.8 21.8 [6.39] 1.8 23.4 [6.86] 1.8 6.0 [1.76] 1.8 7.6 [2.23] 1.8 9.3 [2.73] 1.8 10.9 [3.19] 1.9 12.5 [3.66] 1.9 14.2 [4.16] 1.9 15.8 [4.63] 1.9 17.4 [5.10] 1.9 19.1 [5.60] 2.0 20.7 [6.07] 2.0 22.3 [6.54] 2.0 6.0 [1.76] 1.8 7.6 [2.23] 1.8 9.2 [2.70] 1.9 10.8 [3.17] 1.9 12.5 [3.66] 1.9 14.1 [4.13] 1.9 15.7 [4.60] 2.0 17.3 [5.07] 2.0 18.9 [5.54] 2.0 20.6 [6.04] 2.0 22.2 [6.51] 2.0 5.9 [1.73] 1.9 7.5 [2.20] 1.9 9.1 [2.67] 1.9 10.8 [3.17] 1.9 12.4 [3.63] 1.9 14.0 [4.10] 2.0 15.6 [4.57] 2.0 17.2 [5.04] 2.0 18.8 [5.51] 2.0 20.4 [5.98] 2.0 22.0 [6.45] 2.1 [ ] Designates Metric Conversions 13 Air Gross Systems Performance Data RQNL Series COOLING PERFORMANCE DATA—RQNL-030 ENTERING INDOOR AIR @ 80°F [26.7°C] dbE ➀ wbE CFM [L/s] DR ➀ O U T D O O R D R Y B U L B T E M P E R A T U R E 71°F [21.7°C] 1000 [472] .18 900 [425] .16 1100 [519] .02 67°F [19.4°C] 1000 [472] .18 900 [425] .16 1100 [519] .02 63°F [17.2°C] 1000 [472 .18 900 [425] .16 Total BTUH [kW] 36.1 [10.58] 75 Sens BTUH [kW] 22.0 [6.45] [23.9] 1.9 Power 35.4 [10.37] 21.0 [6.15] 1.9 34.8 [10.20] 20.0 [5.86] 1.8 34.1 [9.99] 25.3 [7.41] 1.8 33.4 [9.79] 24.2 [7.09] 1.8 32.8 [9.61] 23.0 [6.74] 1.8 32.7 [9.58] 26.7 [7.83] 1.9 32.1 [9.41] 25.5 [7.47] 1.9 31.5 [9.23] 24.3 [7.12] 1.8 Total BTUH [kW] 34.9 [10.23] 80 Sens BTUH [kW] 21.4 [6.27] [26.7] 2.0 Power 34.3 [10.05] 20.4 [5.98] 1.9 33.6 [9.85] 19.5 [5.71] 1.9 32.9 [9.64] 24.7 [7.24] 1.9 32.3 [9.47] 23.6 [6.92] 1.9 31.7 [9.29] 22.5 [6.59] 1.9 31.5 [9.23] 26.1 [7.65] 2.0 31.0 [9.09] 25.0 [7.33] 1.9 30.4 [8.91] 23.8 [6.98] 1.9 Total BTUH [kW] 33.8 [9.91] 85 Sens BTUH [kW] 20.8 [6.10] [29.4] 2.1 Power 33.2 [9.73] 19.9 [5.83] 2.0 32.6 [9.55] 19.0 [5.57] 2.0 31.8 [9.32] 24.1 [7.06] 2.0 31.2 [9.14] 23.0 [6.74] 2.0 30.6 [8.97] 22.0 [6.45] 2.0 30.4 [8.91] 25.5 [7.47] 2.1 29.8 [8.73] 24.4 [7.15] 2.0 29.3 [8.59] 23.3 [6.83] 2.0 Total BTUH [kW] 90 Sens BTUH [kW] [32.2] Power Total BTUH [kW] 95 Sens BTUH [kW] [35] Power Total BTUH [kW] 100 Sens BTUH [kW] [37.8] Power 32.6 [9.55] 20.2 [5.92] 2.2 32.0 [9.38] 19.3 [5.66] 2.1 31.5 [9.23] 18.4 [5.39] 2.1 30.6 [8.97] 23.5 [6.89] 2.1 30.1 [8.82] 22.5 [6.59] 2.1 29.5 [8.65] 21.4 [6.27] 2.1 29.3 [8.59] 25.0 [7.33] 2.2 28.7 [8.41] 23.9 [7.00] 2.1 28.2 [8.26] 22.7 [6.65] 2.1 31.5 [9.23] 19.7 [5.77] 2.2 30.9 [9.06] 18.8 [5.51] 2.2 30.4 [8.91] 17.9 [5.25] 2.2 29.5 [8.65] 23.0 [6.74] 2.2 29.0 [8.50] 22.0 [6.45] 2.2 28.4 [8.32] 20.9 [6.13] 2.2 28.1 [8.24] 24.4 [7.15] 2.2 27.6 [8.09] 23.3 [6.83] 2.2 27.1 [7.94] 22.2 [6.51] 2.2 30.3 [8.88] 19.2 [5.63] 2.3 29.8 [8.73] 18.3 [5.36] 2.3 29.3 [8.59] 17.4 [5.10] 2.3 28.3 [8.29] 22.4 [6.56] 2.3 27.8 [8.15] 21.4 [6.27] 2.3 27.3 [8.00] 20.4 [5.98] 2.3 27.0 [7.91] 23.9 [7.00] 2.3 26.5 [7.77] 22.8 [6.68] 2.3 26.0 [7.62] 21.7 [6.36] 2.3 Total BTUH [kW] 29.2 [8.56] 105 Sens BTUH [kW] 18.6 [5.45] [40.6] 2.4 Power 28.6 [8.38] 17.8 [5.22] 2.4 28.1 [8.24] 16.9 [4.95] 2.4 27.2 [7.97] 21.9 [6.42] 2.4 26.7 [7.83] 20.9 [6.13] 2.4 26.2 [7.68] 19.9 [5.83] 2.4 25.8 [7.56] 23.3 [6.83] 2.4 25.3 [7.41] 22.3 [6.54] 2.4 24.9 [7.30] 21.3 [6.24] 2.4 27.4 [8.03] 17.3 [5.07] 2.5 26.1 [7.65] 16.7 [4.89] 2.6 26.9 [7.88] 16.5 [4.84] 2.5 25.7 [7.53] 15.9 [4.66] 2.6 25.9 [7.59] 21.4 [6.27] 2.5 24.6 [7.21] 20.8 [6.10] 2.6 25.5 [7.47] 20.4 [5.98] 2.5 24.2 [7.09] 19.9 [5.83] 2.6 25.0 [7.33] 19.5 [5.71] 2.5 23.7 [6.95] 19.0 [5.57] 2.5 24.6 [7.21] 22.8 [6.68] 2.5 23.3 [6.83] 22.2 [6.51] 2.6 24.1 [7.06] 21.8 [6.39] 2.5 22.8 [6.68] 21.2 [6.21] 2.6 23.7 [6.95] 20.8 [6.10] 2.5 22.4 [6.56] 20.3 [5.95] 2.6 Total BTUH [kW] 110 Sens BTUH [kW] °F [43.3] Power [°C] Total BTUH [kW] 115 Sens BTUH [kW] [46.1] Power DR —Depression ratio dbE —Entering air dry bulb wbE —Entering air wet bulb 1100 [519] .02 27.9 [8.18] 18.1 [5.30] 2.5 26.6 [7.80] 17.5 [5.13] 2.6 Total —Total capacity x 1000 BTUH Sens —Sensible capacity x 1000 BTUH Power —KW input NOTES: ➀ When the entering air dry bulb is other than 80°F [27°C], adjust the sensible capacity from the table by adding [1.10 x CFM x (1 – DR) x (dbE – 80)]. HEATING PERFORMANCE DATA—RQNL-030 IDB CFM [L/s] O U T D O O R D R Y B U L B T E M P E R A T U R E °F [°C] 0 [-17.8] 5 [-15] 10 [-12.2] 15 [-9.4] 20 [-6.7] 25 [-3.9] 30 [-1.1] 35 [1.7] 40 [4.4] 45 [7.2] 50 [10] Total BTUH [kW] Power Total BTUH [kW] Power Total BTUH [kW] Power Total BTUH [kW] Power Total BTUH [kW] Power Total BTUH [kW] Power Total BTUH [kW] Power Total BTUH [kW] Power Total BTUH [kW] Power Total BTUH [kW] Power Total BTUH [kW] Power IDB—Indoor air dry bulb 14 1100 [519] 60°F [15.5°C] 1000 [472] 900 [425] 1100 [519] 70°F [21.1°C] 1000 [472] 900 [425] 1100 [519] 80°F [26.7°C] 1000 [472 900 [425] 9.3 [2.73] 1.6 11.3 [3.31] 1.6 13.2 [3.87] 1.6 15.1 [4.43] 1.7 17.0 [4.98] 1.7 18.9 [5.54] 1.7 20.9 [6.13] 1.8 22.8 [6.68] 1.8 24.7 [7.24] 1.8 26.6 [7.80] 1.9 28.6 [8.38] 1.9 9.3 [2.73] 1.6 11.2 [3.28] 1.6 13.1 [3.84] 1.7 15.0 [4.40] 1.7 16.9 [4.95] 1.7 18.8 [5.51] 1.8 20.7 [6.07] 1.8 22.6 [6.62] 1.8 24.5 [7.18] 1.8 26.4 [7.74] 1.9 28.4 [8.32] 1.9 9.2 [2.70] 1.6 11.1 [3.25] 1.6 13.0 [3.81] 1.7 14.9 [4.37] 1.7 16.8 [4.92] 1.7 18.7 [5.48] 1.8 20.6 [6.04] 1.8 22.5 [6.59] 1.8 24.4 [7.15] 1.9 26.3 [7.71] 1.9 28.2 [8.26] 1.9 7.8 [2.29] 1.8 9.7 [2.84] 1.8 11.6 [3.40] 1.9 13.5 [3.96] 1.9 15.5 [4.54] 1.9 17.4 [5.10] 1.9 19.3 [5.66] 2.0 21.2 [6.21] 2.0 23.2 [6.80] 2.0 25.1 [7.36] 2.1 27.0 [7.91] 2.1 7.7 [2.26] 1.8 9.6 [2.81] 1.8 11.5 [3.37] 1.9 13.5 [3.96] 1.9 15.4 [4.51] 1.9 17.3 [5.07] 2.0 19.2 [5.63] 2.0 21.1 [6.18] 2.0 23.0 [6.74] 2.1 24.9 [7.30] 2.1 26.8 [7.85] 2.1 7.7 [2.26] 1.8 9.6 [2.81] 1.9 11.5 [3.37] 1.9 13.4 [3.93] 1.9 15.3 [4.48] 2.0 17.1 [5.01] 2.0 19.0 [5.57] 2.0 20.9 [6.13] 2.1 22.8 [6.68] 2.1 24.7 [7.24] 2.1 26.6 [7.80] 2.1 6.4 [1.88] 2.0 8.3 [2.43] 2.0 10.2 [2.99] 2.1 12.1 [3.55] 2.1 14.0 [4.10] 2.1 16.0 [4.69] 2.2 17.9 [5.25] 2.2 19.8 [5.80] 2.2 21.7 [6.36] 2.3 23.7 [6.95] 2.3 25.6 [7.50] 2.3 6.3 [1.85] 2.0 8.2 [2.40] 2.1 10.1 [2.96] 2.1 12.0 [3.52] 2.1 13.9 [4.07] 2.2 15.9 [4.66] 2.2 17.8 [5.22] 2.2 19.7 [5.77] 2.3 21.6 [6.33] 2.3 23.5 [6.89] 2.3 25.4 [7.44] 2.4 6.3 [1.85] 2.1 8.2 [2.40] 2.1 10.1 [2.96] 2.1 12.0 [3.52] 2.2 13.8 [4.04] 2.2 15.7 [4.60] 2.2 17.6 [5.16] 2.3 19.5 [5.71] 2.3 21.4 [6.27] 2.3 23.3 [6.83] 2.3 25.2 [7.39] 2.4 [ ] Designates Metric Conversions Air Gross Systems Performance Data RQNL Series COOLING PERFORMANCE DATA—RQNL-036 ENTERING INDOOR AIR @ 80°F [26.7°C] dbE ➀ wbE CFM [L/s] DR ➀ O U T D O O R D R Y B U L B T E M P E R A T U R E 71°F [21.7°C] 1250 [590] .19 1120 [528] .17 1380 [651] .21 67°F [19.4°C] 1250 [590] .19 1120 [528] .17 1380 [651] .21 63°F [17.2°C] 1250 [590] .19 1120 [528] .17 Total BTUH [kW] 44.5 [13.04] 75 Sens BTUH [kW] 27.2 [7.97] [23.9] 2.3 Power 43.7 [12.81] 26.0 [7.62] 2.3 42.9 [12.57] 24.8 [7.27] 2.2 42.5 [12.46] 31.3 [9.17] 2.3 41.7 [12.22] 29.9 [8.76] 2.2 40.9 [11.99] 28.5 [8.35] 2.2 41.3 [12.10] 33.7 [9.88] 2.2 40.6 [11.90] 32.2 [9.44] 2.2 39.8 [11.66] 30.7 [9.00] 2.2 Total BTUH [kW] 43.4 [12.72] 80 Sens BTUH [kW] 26.6 [7.80] [26.7] 2.4 Power 42.6 [12.48] 25.4 [7.44] 2.4 41.8 [12.25] 24.2 [7.09] 2.4 41.3 [12.10] 30.7 [9.00] 2.4 40.6 [11.90] 29.3 [8.59] 2.4 39.9 [11.69] 27.9 [8.18] 2.4 40.2 [11.78] 33.0 [9.67] 2.4 39.5 [11.58] 31.6 [9.26] 2.4 38.8 [11.37] 30.1 [8.82] 2.3 Total BTUH [kW] 42.1 [12.34] 85 Sens BTUH [kW] 26.0 [7.62] [29.4] 2.6 Power 41.3 [12.10] 24.8 [7.27] 2.5 40.6 [11.90] 23.6 [6.92] 2.5 40.0 [11.72] 30.0 [8.79] 2.5 39.3 [11.52] 28.7 [8.41] 2.5 38.6 [11.31] 27.3 [8.00] 2.5 38.9 [11.40] 32.4 [9.50] 2.5 38.2 [11.20] 30.9 [9.06] 2.5 37.5 [10.99] 29.5 [8.65] 2.5 Total BTUH [kW] 90 Sens BTUH [kW] [32.2] Power Total BTUH [kW] 95 Sens BTUH [kW] [35] Power Total BTUH [kW] 100 Sens BTUH [kW] [37.8] Power 40.6 [11.90] 25.3 [7.41] 2.7 39.9 [11.69] 24.1 [7.06] 2.7 39.1 [11.46] 23.0 [6.74] 2.7 38.5 [11.28] 29.3 [8.59] 2.7 37.9 [11.11] 28.0 [8.21] 2.7 37.2 [10.90] 26.7 [7.83] 2.6 37.4 [10.96] 31.7 [9.29] 2.7 36.7 [10.76] 30.3 [8.88] 2.6 36.1 [10.58] 28.8 [8.44] 2.6 39.0 [11.43] 24.5 [7.18] 2.9 38.3 [11.22] 23.4 [6.86] 2.8 37.6 [11.02] 22.3 [6.54] 2.8 36.9 [10.81] 28.6 [8.38] 2.8 36.3 [10.64] 27.3 [8.00] 2.8 35.6 [10.43] 26.0 [7.62] 2.8 35.8 [10.49] 30.9 [9.06] 2.8 35.2 [10.32] 29.6 [8.67] 2.8 34.5 [10.11] 28.2 [8.26] 2.8 37.3 [10.93] 23.7 [6.95] 3.0 36.7 [10.76] 22.7 [6.65] 3.0 36.0 [10.55] 21.6 [6.33] 2.9 35.3 [10.35] 27.8 [8.15] 3.0 34.6 [10.14] 26.5 [7.77] 2.9 34.0 [9.96] 25.3 [7.41] 2.9 34.1 [9.99] 30.2 [8.85] 3.0 33.5 [9.82] 28.8 [8.44] 2.9 32.9 [9.64] 27.5 [8.06] 2.9 Total BTUH [kW] 35.6 [10.43] 105 Sens BTUH [kW] 22.9 [6.71] [40.6] 3.1 Power 35.0 [10.26] 21.9 [6.42] 3.1 34.4 [10.08] 20.9 [6.13] 3.1 33.6 [9.85] 27.0 [7.91] 3.1 33.0 [9.67] 25.8 [7.56] 3.1 32.4 [9.50] 24.6 [7.21] 3.1 32.4 [9.50] 29.4 [8.62] 3.1 31.9 [9.35] 28.1 [8.24] 3.1 31.3 [9.17] 26.7 [7.83] 3.0 33.4 [9.79] 21.1 [6.18] 3.3 31.8 [9.32] 20.3 [5.95] 3.4 32.7 [9.58] 20.1 [5.89] 3.2 31.2 [9.14] 19.4 [5.69] 3.4 31.9 [9.35] 26.2 [7.68] 3.3 30.3 [8.88] 25.3 [7.41] 3.4 31.3 [9.17] 25.0 [7.33] 3.2 29.8 [8.73] 24.2 [7.09] 3.4 30.8 [9.03] 23.8 [6.98] 3.2 29.2 [8.56] 23.1 [6.77] 3.3 30.8 [9.03] 28.5 [8.35] 3.2 29.2 [8.56] 27.7 [8.12] 3.4 30.2 [8.85] 27.3 [8.00] 3.2 28.6 [8.38] 26.5 [7.77] 3.4 29.7 [8.70] 26.0 [7.62] 3.2 28.1 [8.24] 25.2 [7.39] 3.3 Total BTUH [kW] 110 Sens BTUH [kW] °F [43.3] Power [°C] Total BTUH [kW] 115 Sens BTUH [kW] [46.1] Power DR —Depression ratio dbE —Entering air dry bulb wbE —Entering air wet bulb 1380 [651] .21 34.0 [9.96] 22.1 [6.48] 3.3 32.4 [9.50] 21.3 [6.24] 3.4 Total —Total capacity x 1000 BTUH Sens —Sensible capacity x 1000 BTUH Power —KW input NOTES: ➀ When the entering air dry bulb is other than 80°F [27°C], adjust the sensible capacity from the table by adding [1.10 x CFM x (1 – DR) x (dbE – 80)]. HEATING PERFORMANCE DATA—RQNL-036 IDB CFM [L/s] O U T D O O R D R Y B U L B T E M P E R A T U R E °F [°C] 0 [-17.8] 5 [-15] 10 [-12.2] 15 [-9.4] 20 [-6.7] 25 [-3.9] 30 [-1.1] 35 [1.7] 40 [4.4] 45 [7.2] 50 [10] Total BTUH [kW] Power Total BTUH [kW] Power Total BTUH [kW] Power Total BTUH [kW] Power Total BTUH [kW] Power Total BTUH [kW] Power Total BTUH [kW] Power Total BTUH [kW] Power Total BTUH [kW] Power Total BTUH [kW] Power Total BTUH [kW] Power IDB—Indoor air dry bulb 1380 [651] 60°F [15.5°C] 1250 [590] 1120 [528] 1380 [651] 70°F [21.1°C] 1250 [590] 1120 [528] 1380 [651] 80°F [26.7°C] 1250 [590] 1120 [528] 11.9 [3.49] 1.8 14.4 [4.22] 1.9 16.8 [4.92] 1.9 19.3 [5.66] 1.9 21.7 [6.36] 2.0 24.2 [7.09] 2.0 26.7 [7.83] 2.1 29.1 [8.53] 2.1 31.6 [9.26] 2.1 34.0 [9.96] 2.2 36.5 [10.70] 2.2 11.9 [3.49] 1.8 14.3 [4.19] 1.9 16.7 [4.89] 1.9 19.2 [5.63] 2.0 21.6 [6.33] 2.0 24.0 [7.03] 2.0 26.5 [7.77] 2.1 28.9 [8.47] 2.1 31.3 [9.17] 2.2 33.8 [9.91] 2.2 36.2 [10.61] 2.2 11.8 [3.46] 1.9 14.2 [4.16] 1.9 16.6 [4.86] 1.9 19.0 [5.57] 2.0 21.4 [6.27] 2.0 23.9 [7.00] 2.1 26.3 [7.71] 2.1 28.7 [8.41] 2.2 31.1 [9.11] 2.2 33.5 [9.82] 2.2 35.9 [10.52] 2.3 9.9 [2.90] 2.1 12.4 [3.63] 2.1 14.8 [4.34] 2.2 17.3 [5.07] 2.2 19.7 [5.77] 2.2 22.2 [6.51] 2.3 24.6 [7.21] 2.3 27.1 [7.94] 2.4 29.5 [8.65] 2.4 32.0 [9.38] 2.4 34.4 [10.08] 2.5 9.8 [2.87] 2.1 12.3 [3.60] 2.1 14.7 [4.31] 2.2 17.1 [5.01] 2.2 19.6 [5.74] 2.3 22.0 [6.45] 2.3 24.4 [7.15] 2.3 26.9 [7.88] 2.4 29.3 [8.59] 2.4 31.7 [9.29] 2.5 34.2 [10.02] 2.5 9.8 [2.87] 2.1 12.2 [3.58] 2.2 14.6 [4.28] 2.2 17.0 [4.98] 2.2 19.4 [5.69] 2.3 21.8 [6.39] 2.3 24.3 [7.12] 2.4 26.7 [7.83] 2.4 29.1 [8.53] 2.5 31.5 [9.23] 2.5 33.9 [9.94] 2.5 8.5 [2.49] 2.4 11.0 [3.22] 2.4 13.4 [3.93] 2.4 15.9 [4.66] 2.5 18.3 [5.36] 2.5 20.8 [6.10] 2.6 23.2 [6.80] 2.6 25.7 [7.53] 2.6 28.1 [8.24] 2.7 30.6 [8.97] 2.7 33.0 [9.67] 2.8 8.5 [2.49] 2.4 10.9 [3.19] 2.4 13.3 [3.90] 2.5 15.8 [4.63] 2.5 18.2 [5.33] 2.6 20.6 [6.04] 2.6 23.1 [6.77] 2.6 25.5 [7.47] 2.7 27.9 [8.18] 2.7 30.4 [8.91] 2.8 32.8 [9.61] 2.8 8.4 [2.46] 2.4 10.8 [3.17] 2.5 13.2 [3.87] 2.5 15.7 [4.60] 2.5 18.1 [5.30] 2.6 20.5 [6.01] 2.6 22.9 [6.71] 2.7 25.3 [7.41] 2.7 27.7 [8.12] 2.8 30.2 [8.85] 2.8 32.6 [9.55] 2.8 [ ] Designates Metric Conversions 15 Air Gross Systems Performance Data RQNL Series COOLING PERFORMANCE DATA—RQNL-042 ENTERING INDOOR AIR @ 80°F [26.7°C] dbE ➀ wbE CFM [L/s] DR ➀ O U T D O O R D R Y B U L B T E M P E R A T U R E 71°F [21.7°C] 1400 [661] .15 1260 [595] .14 1540 [727] .17 67°F [19.4°C] 1400 [661] .15 1260 [595] .14 1540 [727] .17 63°F [17.2°C] 1400 [661] .15 1260 [595] .14 Total BTUH [kW] 53.9 [15.80] 75 Sens BTUH [kW] 32.2 [9.44] [23.9] 2.9 Power 52.9 [15.50] 30.7 [9.00] 2.9 51.9 [15.21] 29.3 [8.59] 2.9 50.9 [14.92] 37.1 [10.87] 2.9 50.0 [14.65] 35.5 [10.40] 2.9 49.1 [14.39] 33.8 [9.91] 2.9 48.1 [14.10] 39.3 [11.52] 2.9 47.3 [13.86] 37.5 [10.99] 2.9 46.4 [13.60] 35.8 [10.49] 2.9 Total BTUH [kW] 52.0 [15.24] 80 Sens BTUH [kW] 31.3 [9.17] [26.7] 3.1 Power 51.0 [14.95] 29.9 [8.76] 3.1 50.1 [14.68] 28.5 [8.35] 3.1 49.0 [14.36] 36.3 [10.64] 3.1 48.1 [14.10] 34.7 [10.17] 3.1 47.2 [13.83] 33.0 [9.67] 3.1 46.2 [13.54] 38.4 [11.25] 3.1 45.4 [13.31] 36.7 [10.76] 3.1 44.6 [13.07] 35.0 [10.26] 3.0 Total BTUH [kW] 50.3 [14.74] 85 Sens BTUH [kW] 30.5 [8.94] [29.4] 3.3 Power 49.4 [14.48] 29.2 [8.56] 3.3 48.5 [14.21] 27.8 [8.15] 3.2 47.3 [13.86] 35.5 [10.40] 3.3 46.5 [13.63] 33.9 [9.94] 3.2 45.6 [13.36] 32.3 [9.47] 3.2 44.6 [13.07] 37.6 [11.02] 3.3 43.8 [12.84] 35.9 [10.52] 3.2 43.0 [12.60] 34.3 [10.05] 3.2 Total BTUH [kW] 90 Sens BTUH [kW] [32.2] Power Total BTUH [kW] 95 Sens BTUH [kW] [35] Power Total BTUH [kW] 100 Sens BTUH [kW] [37.8] Power 48.7 [14.27] 29.8 [8.73] 3.4 47.9 [14.04] 28.4 [8.32] 3.4 47.0 [13.77] 27.1 [7.94] 3.4 45.8 [13.42] 34.7 [10.17] 3.4 44.9 [13.16] 33.2 [9.73] 3.4 44.1 [12.92] 31.6 [9.26] 3.4 43.0 [12.60] 36.8 [10.79] 3.4 42.2 [12.37] 35.2 [10.32] 3.4 41.5 [12.16] 33.6 [9.85] 3.4 47.2 [13.83] 29.0 [8.50] 3.6 46.4 [13.60] 27.7 [8.12] 3.6 45.5 [13.33] 26.4 [7.74] 3.6 44.2 [12.95] 34.0 [9.96] 3.6 43.4 [12.72] 32.4 [9.50] 3.6 42.7 [12.51] 30.9 [9.06] 3.6 41.5 [12.16] 36.1 [10.58] 3.6 40.7 [11.93] 34.5 [10.11] 3.6 40.0 [11.72] 32.9 [9.64] 3.5 45.6 [13.36] 28.2 [8.26] 3.8 44.8 [13.13] 26.9 [7.88] 3.8 44.0 [12.90] 25.7 [7.53] 3.7 42.6 [12.48] 33.2 [9.73] 3.8 41.9 [12.28] 31.7 [9.29] 3.7 41.1 [12.05] 30.2 [8.85] 3.7 39.9 [11.69] 35.3 [10.35] 3.8 39.2 [11.49] 33.7 [9.88] 3.7 38.5 [11.28] 32.1 [9.41] 3.7 Total BTUH [kW] 43.8 [12.84] 105 Sens BTUH [kW] 27.4 [8.03] [40.6] 4.0 Power 43.0 [12.60] 26.1 [7.65] 3.9 42.3 [12.40] 24.9 [7.30] 3.9 40.8 [11.96] 32.3 [9.47] 3.9 40.1 [11.75] 30.9 [9.06] 3.9 39.4 [11.55] 29.4 [8.62] 3.9 38.1 [11.17] 34.4 [10.08] 3.9 37.4 [10.96] 32.9 [9.64] 3.9 36.7 [10.76] 31.4 [9.20] 3.9 41.0 [12.02] 25.2 [7.39] 4.1 38.6 [11.31] 24.2 [7.09] 4.3 40.2 [11.78] 24.1 [7.06] 4.1 37.9 [11.11] 23.1 [6.77] 4.2 38.8 [11.37] 31.4 [9.20] 4.1 36.3 [10.64] 30.3 [8.88] 4.3 38.1 [11.17] 30.0 [8.79] 4.1 35.6 [10.43] 29.0 [8.50] 4.2 37.4 [10.96] 28.6 [8.38] 4.0 35.0 [10.26] 27.6 [8.09] 4.2 36.0 [10.55] 33.5 [9.82] 4.1 33.5 [9.82] 32.4 [9.50] 4.3 35.4 [10.37] 32.0 [9.38] 4.1 32.9 [9.64] 31.0 [9.09] 4.2 34.7 [10.17] 30.5 [8.94] 4.0 32.3 [9.47] 29.5 [8.65] 4.2 Total BTUH [kW] 110 Sens BTUH [kW] °F [43.3] Power [°C] Total BTUH [kW] 115 Sens BTUH [kW] [46.1] Power DR —Depression ratio dbE —Entering air dry bulb wbE —Entering air wet bulb 1540 [727] .17 41.7 [12.22] 26.4 [7.74] 4.1 39.3 [11.52] 25.4 [7.44] 4.3 Total —Total capacity x 1000 BTUH Sens —Sensible capacity x 1000 BTUH Power —KW input NOTES: ➀ When the entering air dry bulb is other than 80°F [27°C], adjust the sensible capacity from the table by adding [1.10 x CFM x (1 – DR) x (dbE – 80)]. HEATING PERFORMANCE DATA—RQNL-042 IDB CFM [L/s] O U T D O O R D R Y B U L B T E M P E R A T U R E °F [°C] 0 [-17.8] 5 [-15] 10 [-12.2] 15 [-9.4] 20 [-6.7] 25 [-3.9] 30 [-1.1] 35 [1.7] 40 [4.4] 45 [7.2] 50 [10] Total BTUH [kW] Power Total BTUH [kW] Power Total BTUH [kW] Power Total BTUH [kW] Power Total BTUH [kW] Power Total BTUH [kW] Power Total BTUH [kW] Power Total BTUH [kW] Power Total BTUH [kW] Power Total BTUH [kW] Power Total BTUH [kW] Power IDB—Indoor air dry bulb 16 1540 [727] 60°F [15.5°C] 1400 [661] 1260 [595] 1540 [727] 70°F [21.1°C] 1400 [661] 1260 [595] 1540 [727] 80°F [26.7°C] 1400 [661] 1260 [595] 13.9 [4.07] 2.6 16.9 [4.95] 2.6 20.0 [5.86] 2.6 23.0 [6.74] 2.7 26.0 [7.62] 2.7 29.0 [8.50] 2.8 32.0 [9.38] 2.8 35.1 [10.29] 2.8 38.1 [11.17] 2.9 41.1 [12.05] 2.9 44.1 [12.92] 2.9 13.8 [4.04] 2.6 16.8 [4.92] 2.6 19.8 [5.80] 2.7 22.8 [6.68] 2.7 25.8 [7.56] 2.7 28.8 [8.44] 2.8 31.8 [9.32] 2.8 34.8 [10.20] 2.9 37.8 [11.08] 2.9 40.8 [11.96] 2.9 43.8 [12.84] 3.0 13.7 [4.02] 2.6 16.7 [4.89] 2.7 19.7 [5.77] 2.7 22.6 [6.62] 2.7 25.6 [7.50] 2.8 28.6 [8.38] 2.8 31.6 [9.26] 2.9 34.6 [10.14] 2.9 37.5 [10.99] 2.9 40.5 [11.87] 3.0 43.5 [12.75] 3.0 12.9 [3.78] 3.0 16.0 [4.69] 3.0 19.0 [5.57] 3.1 22.0 [6.45] 3.1 25.0 [7.33] 3.1 28.0 [8.21] 3.2 31.1 [9.11] 3.2 34.1 [9.99] 3.2 37.1 [10.87] 3.3 40.1 [11.75] 3.3 43.1 [12.63] 3.4 12.8 [3.75] 3.0 15.8 [4.63] 3.1 18.8 [5.51] 3.1 21.8 [6.39] 3.1 24.8 [7.27] 3.2 27.8 [8.15] 3.2 30.8 [9.03] 3.2 33.8 [9.91] 3.3 36.8 [10.79] 3.3 39.8 [11.66] 3.4 42.8 [12.54] 3.4 12.8 [3.75] 3.1 15.7 [4.60] 3.1 18.7 [5.48] 3.1 21.7 [6.36] 3.2 24.7 [7.24] 3.2 27.6 [8.09] 3.3 30.6 [8.97] 3.3 33.6 [9.85] 3.3 36.6 [10.73] 3.4 39.6 [11.61] 3.4 42.5 [12.46] 3.4 11.2 [3.28] 3.3 14.2 [4.16] 3.4 17.3 [5.07] 3.4 20.3 [5.95] 3.5 23.3 [6.83] 3.5 26.3 [7.71] 3.5 29.3 [8.59] 3.6 32.4 [9.50] 3.6 35.4 [10.37] 3.6 38.4 [11.25] 3.7 41.4 [12.13] 3.7 11.1 [3.25] 3.4 14.1 [4.13] 3.4 17.1 [5.01] 3.5 20.1 [5.89] 3.5 23.1 [6.77] 3.5 26.1 [7.65] 3.6 29.1 [8.53] 3.6 32.1 [9.41] 3.6 35.1 [10.29] 3.7 38.1 [11.17] 3.7 41.1 [12.05] 3.8 11.1 [3.25] 3.4 14.0 [4.10] 3.5 17.0 [4.98] 3.5 20.0 [5.86] 3.5 23.0 [6.74] 3.6 25.9 [7.59] 3.6 28.9 [8.47] 3.7 31.9 [9.35] 3.7 34.9 [10.23] 3.7 37.9 [11.11] 3.8 40.8 [11.96] 3.8 [ ] Designates Metric Conversions Air Gross Systems Performance Data RQNL Series COOLING PERFORMANCE DATA—RQNL-048 ENTERING INDOOR AIR @ 80°F [26.7°C] dbE ➀ wbE CFM [L/s] DR ➀ O U T D O O R D R Y B U L B T E M P E R A T U R E 71°F [21.7°C] 1600 [755] .13 1440 [680] .11 1760 [831] .15 67°F [19.4°C] 1600 [755] .13 1440 [680] .11 1760 [831] .15 63°F [17.2°C] 1600 [755] .13 1440 [680] .11 Total BTUH [kW] 60.4 [17.70] 75 Sens BTUH [kW] 37.4 [10.96] [23.9] 3.2 Power 59.3 [17.38] 35.7 [10.46] 3.2 58.3 [17.09] 34.1 [9.99] 3.2 57.1 [16.73] 42.7 [12.51] 3.2 56.1 [16.44] 40.8 [11.96] 3.2 55.0 [16.12] 38.9 [11.40] 3.1 54.5 [15.97] 45.0 [13.19] 3.2 53.5 [15.68] 43.0 [12.60] 3.1 52.5 [15.39] 41.0 [12.02] 3.1 Total BTUH [kW] 58.8 [17.23] 80 Sens BTUH [kW] 36.6 [10.73] [26.7] 3.4 Power 57.8 [16.94] 35.0 [10.26] 3.4 56.7 [16.62] 33.3 [9.76] 3.3 55.5 [16.27] 41.9 [12.28] 3.4 54.5 [15.97] 40.0 [11.72] 3.4 53.5 [15.68] 38.2 [11.20] 3.3 52.9 [15.50] 44.2 [12.95] 3.4 51.9 [15.21] 42.2 [12.37] 3.3 51.0 [14.95] 40.3 [11.81] 3.3 Total BTUH [kW] 57.0 [16.71] 85 Sens BTUH [kW] 35.7 [10.46] [29.4] 3.6 Power 56.0 [16.41] 34.1 [9.99] 3.6 55.0 [16.12] 32.5 [9.52] 3.5 53.7 [15.74] 41.0 [12.02] 3.6 52.7 [15.44] 39.2 [11.49] 3.5 51.8 [15.18] 37.3 [10.93] 3.5 51.1 [14.98] 43.3 [12.69] 3.5 50.2 [14.71] 41.4 [12.13] 3.5 49.3 [14.45] 39.4 [11.55] 3.5 Total BTUH [kW] 90 Sens BTUH [kW] [32.2] Power Total BTUH [kW] 95 Sens BTUH [kW] [35] Power Total BTUH [kW] 100 Sens BTUH [kW] [37.8] Power 55.1 [16.15] 34.8 [10.20] 3.8 54.1 [15.86] 33.2 [9.73] 3.7 53.1 [15.56] 31.7 [9.29] 3.7 51.7 [15.15] 40.1 [11.75] 3.8 50.8 [14.89] 38.3 [11.22] 3.7 49.9 [14.62] 36.5 [10.70] 3.7 49.1 [14.39] 42.4 [12.43] 3.7 48.3 [14.16] 40.5 [11.87] 3.7 47.4 [13.89] 38.6 [11.31] 3.7 53.1 [15.56] 33.8 [9.91] 4.0 52.1 [15.27] 32.3 [9.47] 3.9 51.2 [15.01] 30.8 [9.03] 3.9 49.8 [14.59] 39.1 [11.46] 3.9 48.9 [14.33] 37.4 [10.96] 3.9 48.0 [14.07] 35.6 [10.43] 3.9 47.2 [13.83] 41.4 [12.13] 3.9 46.3 [13.57] 39.6 [11.61] 3.9 45.5 [13.33] 37.7 [11.05] 3.9 51.1 [14.98] 32.9 [9.64] 4.2 50.2 [14.71] 31.4 [9.20] 4.1 49.3 [14.45] 29.9 [8.76] 4.1 47.8 [14.01] 38.2 [11.20] 4.1 46.9 [13.75] 36.5 [10.70] 4.1 46.1 [13.51] 34.8 [10.20] 4.1 45.2 [13.25] 40.5 [11.87] 4.1 44.4 [13.01] 38.7 [11.34] 4.1 43.6 [12.78] 36.9 [10.81] 4.0 Total BTUH [kW] 49.3 [14.45] 105 Sens BTUH [kW] 32.0 [9.38] [40.6] 4.3 Power 48.4 [14.18] 30.6 [8.97] 4.3 47.5 [13.92] 29.2 [8.56] 4.3 46.0 [13.48] 37.3 [10.93] 4.3 45.1 [13.22] 35.7 [10.46] 4.3 44.3 [12.98] 34.0 [9.96] 4.2 43.4 [12.72] 39.6 [11.61] 4.3 42.6 [12.48] 37.9 [11.11] 4.3 41.8 [12.25] 36.1 [10.58] 4.2 46.8 [13.72] 29.9 [8.76] 4.5 45.5 [13.33] 29.3 [8.59] 4.7 45.9 [13.45] 28.5 [8.35] 4.5 44.6 [13.07] 27.9 [8.18] 4.6 44.3 [12.98] 36.6 [10.73] 4.5 43.0 [12.60] 36.0 [10.55] 4.7 43.5 [12.75] 34.9 [10.23] 4.5 42.2 [12.37] 34.4 [10.08] 4.7 42.7 [12.51] 33.3 [9.76] 4.4 41.4 [12.13] 32.8 [9.61] 4.6 41.7 [12.22] 38.9 [11.40] 4.5 40.4 [11.84] 38.3 [11.22] 4.7 41.0 [12.02] 37.1 [10.87] 4.4 39.6 [11.61] 36.6 [10.73] 4.6 40.2 [11.78] 35.4 [10.37] 4.4 38.9 [11.40] 34.8 [10.20] 4.6 Total BTUH [kW] 110 Sens BTUH [kW] °F [43.3] Power [°C] Total BTUH [kW] 115 Sens BTUH [kW] [46.1] Power DR —Depression ratio dbE —Entering air dry bulb wbE —Entering air wet bulb 1760 [831] .15 47.6 [13.95] 31.3 [9.17] 4.5 46.3 [13.57] 30.7 [9.00] 4.7 Total —Total capacity x 1000 BTUH Sens —Sensible capacity x 1000 BTUH Power —KW input NOTES: ➀ When the entering air dry bulb is other than 80°F [27°C], adjust the sensible capacity from the table by adding [1.10 x CFM x (1 – DR) x (dbE – 80)]. HEATING PERFORMANCE DATA—RQNL-048 IDB CFM [L/s] O U T D O O R D R Y B U L B T E M P E R A T U R E °F [°C] 0 [-17.8] 5 [-15] 10 [-12.2] 15 [-9.4] 20 [-6.7] 25 [-3.9] 30 [-1.1] 35 [1.7] 40 [4.4] 45 [7.2] 50 [10] Total BTUH [kW] Power Total BTUH [kW] Power Total BTUH [kW] Power Total BTUH [kW] Power Total BTUH [kW] Power Total BTUH [kW] Power Total BTUH [kW] Power Total BTUH [kW] Power Total BTUH [kW] Power Total BTUH [kW] Power Total BTUH [kW] Power IDB—Indoor air dry bulb 1760 [831] 60°F [15.5°C] 1600 [755] 1440 [680] 1760 [831] 70°F [21.1°C] 1600 [755] 1440 [680] 1760 [831] 80°F [26.7°C] 1600 [755] 1440 [680] 16.9 [4.95] 2.6 20.1 [5.89] 2.6 23.2 [6.80] 2.7 26.4 [7.74] 2.7 29.5 [8.65] 2.8 32.7 [9.58] 2.8 35.9 [10.52] 2.9 39.0 [11.43] 2.9 42.2 [12.37] 3.0 45.3 [13.28] 3.0 48.5 [14.21] 3.1 16.8 [4.92] 2.6 19.9 [5.83] 2.6 23.1 [6.77] 2.7 26.2 [7.68] 2.8 29.3 [8.59] 2.8 32.5 [9.52] 2.9 35.6 [10.43] 2.9 38.7 [11.34] 3.0 41.9 [12.28] 3.0 45.0 [13.19] 3.1 48.1 [14.10] 3.1 16.7 [4.89] 2.6 19.8 [5.80] 2.7 22.9 [6.71] 2.7 26.0 [7.62] 2.8 29.1 [8.53] 2.8 32.2 [9.44] 2.9 35.4 [10.37] 2.9 38.5 [11.28] 3.0 41.6 [12.19] 3.1 44.7 [13.10] 3.1 47.8 [14.01] 3.2 15.4 [4.51] 3.0 18.6 [5.45] 3.0 21.8 [6.39] 3.1 24.9 [7.30] 3.1 28.1 [8.24] 3.2 31.2 [9.14] 3.2 34.4 [10.08] 3.3 37.5 [10.99] 3.3 40.7 [11.93] 3.4 43.9 [12.87] 3.4 47.0 [13.77] 3.5 15.3 [4.48] 3.0 18.5 [5.42] 3.0 21.6 [6.33] 3.1 24.7 [7.24] 3.2 27.9 [8.18] 3.2 31.0 [9.09] 3.3 34.1 [9.99] 3.3 37.3 [10.93] 3.4 40.4 [11.84] 3.4 43.6 [12.78] 3.5 46.7 [13.69] 3.5 15.2 [4.45] 3.0 18.3 [5.36] 3.1 21.5 [6.30] 3.1 24.6 [7.21] 3.2 27.7 [8.12] 3.2 30.8 [9.03] 3.3 33.9 [9.94] 3.4 37.0 [10.84] 3.4 40.1 [11.75] 3.5 43.2 [12.66] 3.5 46.4 [13.60] 3.6 14.4 [4.22] 3.4 17.6 [5.16] 3.5 20.7 [6.07] 3.5 23.9 [7.00] 3.6 27.1 [7.94] 3.6 30.2 [8.85] 3.7 33.4 [9.79] 3.7 36.5 [10.70] 3.8 39.7 [11.63] 3.8 42.8 [12.54] 3.9 46.0 [13.48] 3.9 14.3 [4.19] 3.5 17.5 [5.13] 3.5 20.6 [6.04] 3.6 23.7 [6.95] 3.6 26.9 [7.88] 3.7 30.0 [8.79] 3.7 33.1 [9.70] 3.8 36.3 [10.64] 3.8 39.4 [11.55] 3.9 42.5 [12.46] 3.9 45.7 [13.39] 4.0 14.2 [4.16] 3.5 17.3 [5.07] 3.5 20.4 [5.98] 3.6 23.6 [6.92] 3.7 26.7 [7.83] 3.7 29.8 [8.73] 3.8 32.9 [9.64] 3.8 36.0 [10.55] 3.9 39.1 [11.46] 3.9 42.2 [12.37] 4.0 45.3 [13.28] 4.0 [ ] Designates Metric Conversions 17 Air Gross Systems Performance Data RQPL Series COOLING PERFORMANCE DATA—RQPL-024 ENTERING INDOOR AIR @ 80°F [26.7°C] dbE ➀ wbE CFM [L/s] DR ➀ 940 [444] .15 71°F [21.7°C] 850 [401] .13 760 [359] .11 940 [444] .15 67°F [19.4°C] 850 [401] .13 760 [359] .11 940 [444] .15 63°F [17.2°C] 850 [401] .13 760 [359] .11 Total BTUH [kW] 75 Sens BTUH [kW] [23.9] Power 29.9 [8.76] 19.2 [5.63] 1.5 29.4 [8.62] 18.4 [5.39] 1.5 28.8 [8.44] 17.5 [5.13] 1.5 28.6 [8.38] 22.0 [6.45] 1.5 28.0 [8.21] 21.0 [6.15] 1.5 27.5 [8.06] 20.1 [5.89] 1.5 27.6 [8.09] 23.3 [6.83] 1.5 27.1 [7.94] 22.3 [6.54] 1.5 26.6 [7.80] 21.2 [6.21] 1.5 Total BTUH [kW] 80 Sens BTUH [kW] [26.7] Power 29.7 [8.70] 19.0 [5.57] 1.6 29.1 [8.53] 18.1 [5.30] 1.6 28.6 [8.38] 17.3 [5.07] 1.6 28.3 [8.29] 21.8 [6.39] 1.6 27.8 [8.15] 20.8 [6.10] 1.6 27.3 [8.00] 19.9 [5.83] 1.6 27.3 [8.00] 23.1 [6.77] 1.6 26.8 [7.85] 22.1 [6.48] 1.6 26.4 [7.74] 21.0 [6.15] 1.6 Total BTUH [kW] 85 Sens BTUH [kW] [29.4] Power 29.0 [8.50] 18.6 [5.45] 1.7 28.5 [8.35] 17.8 [5.22] 1.7 27.9 [8.18] 16.9 [4.95] 1.7 27.6 [8.09] 21.4 [6.27] 1.7 27.2 [7.97] 20.5 [6.01] 1.7 26.7 [7.83] 19.5 [5.71] 1.7 26.7 [7.83] 22.7 [6.65] 1.7 26.2 [7.68] 21.7 [6.36] 1.7 25.7 [7.53] 20.7 [6.07] 1.7 Total BTUH [kW] 90 Sens BTUH [kW] [32.2] Power Total BTUH [kW] 95 Sens BTUH [kW] [35] Power Total BTUH [kW] 100 Sens BTUH [kW] [37.8] Power 28.0 [8.21] 18.1 [5.30] 1.8 27.5 [8.06] 17.3 [5.07] 1.8 27.0 [7.91] 16.5 [4.84] 1.8 26.6 [7.80] 20.9 [6.13] 1.8 26.2 [7.68] 20.0 [5.86] 1.8 25.7 [7.53] 19.1 [5.60] 1.8 25.6 [7.50] 22.2 [6.51] 1.8 25.2 [7.39] 21.2 [6.21] 1.8 24.7 [7.24] 20.2 [5.92] 1.8 26.7 [7.83] 17.5 [5.13] 1.9 26.3 [7.71] 16.7 [4.89] 1.9 25.8 [7.56] 16.0 [4.69] 1.9 25.4 [7.44] 20.4 [5.98] 1.9 24.9 [7.30] 19.4 [5.69] 1.9 24.5 [7.18] 18.5 [5.42] 1.9 24.4 [7.15] 21.6 [6.33] 1.9 24.0 [7.03] 20.7 [6.07] 1.9 23.5 [6.89] 19.7 [5.77] 1.9 25.4 [7.44] 16.9 [4.95] 2.0 24.9 [7.30] 16.1 [4.72] 2.0 24.5 [7.18] 15.4 [4.51] 2.0 24.0 [7.03] 19.7 [5.77] 2.0 23.6 [6.92] 18.8 [5.51] 2.0 23.2 [6.80] 18.0 [5.28] 2.0 23.0 [6.74] 21.0 [6.15] 2.0 22.6 [6.62] 20.1 [5.89] 2.0 22.2 [6.51] 19.1 [5.60] 2.0 Total BTUH [kW] 105 Sens BTUH [kW] [40.6] Power 24.0 [7.03] 16.3 [4.78] 2.1 23.6 [6.92] 15.5 [4.54] 2.1 23.1 [6.77] 14.8 [4.34] 2.1 22.6 [6.62] 19.1 [5.60] 2.1 22.2 [6.51] 18.2 [5.33] 2.1 21.8 [6.39] 17.4 [5.10] 2.1 21.7 [6.36] 20.4 [5.98] 2.1 21.3 [6.24] 19.5 [5.71] 2.1 20.9 [6.13] 18.5 [5.42] 2.1 Total BTUH [kW] 110 Sens BTUH [kW] °F [43.3] Power [°C] Total BTUH [kW] 115 Sens BTUH [kW] [46.1] Power 22.7 [6.65] 15.6 [4.57] 2.2 21.6 [6.33] 15.1 [4.43] 2.3 22.3 [6.54] 14.9 [4.37] 2.2 21.2 [6.21] 14.4 [4.22] 2.3 21.9 [6.42] 14.2 [4.16] 2.2 20.8 [6.10] 13.7 [4.02] 2.3 21.4 [6.27] 18.5 [5.42] 2.2 20.2 [5.92] 17.9 [5.25] 2.3 21.0 [6.15] 17.6 [5.16] 2.2 19.9 [5.83] 17.1 [5.01] 2.3 20.6 [6.04] 16.8 [4.92] 2.2 19.5 [5.71] 16.3 [4.78] 2.3 20.4 [5.98] 19.7 [5.77] 2.2 19.3 [5.66] 19.2 [5.63] 2.3 20.0 [5.86] 18.9 [5.54] 2.2 18.9 [5.54] 18.3 [5.36] 2.3 19.6 [5.74] 18.0 [5.28] 2.2 18.6 [5.45] 17.5 [5.13] 2.3 O U T D O O R D R Y B U L B T E M P E R A T U R E DR —Depression ratio dbE —Entering air dry bulb wbE —Entering air wet bulb Total —Total capacity x 1000 BTUH Sens —Sensible capacity x 1000 BTUH Power —KW input NOTES: ➀ When the entering air dry bulb is other than 80°F [27°C], adjust the sensible capacity from the table by adding [1.10 x CFM x (1 – DR) x (dbE – 80)]. HEATING PERFORMANCE DATA—RQPL-024 IDB CFM [L/s] O U T D O O R D R Y B U L B T E M P E R A T U R E °F [°C] 0 [-17.8] 5 [-15] 10 [-12.2] 15 [-9.4] 20 [-6.7] 25 [-3.9] 30 [-1.1] 35 [1.7] 40 [4.4] 45 [7.2] 50 [10] Total BTUH [kW] Power Total BTUH [kW] Power Total BTUH [kW] Power Total BTUH [kW] Power Total BTUH [kW] Power Total BTUH [kW] Power Total BTUH [kW] Power Total BTUH [kW] Power Total BTUH [kW] Power Total BTUH [kW] Power Total BTUH [kW] Power IDB—Indoor air dry bulb 18 940 [444] 60°F [15.5°C] 850 [401] 760 [359] 940 [444] 70°F [21.1°C] 850 [401] 760 [359] 940 [444] 80°F [26.7°C] 850 [401] 760 [359] 8.9 [2.61] 1.4 10.5 [3.08] 1.4 12.1 [3.55] 1.4 13.8 [4.04] 1.5 15.4 [4.51] 1.5 17.1 [5.01] 1.5 18.7 [5.48] 1.5 20.3 [5.95] 1.5 22.0 [6.45] 1.6 23.6 [6.92] 1.6 25.2 [7.39] 1.6 8.8 [2.58] 1.4 10.4 [3.05] 1.4 12.1 [3.55] 1.5 13.7 [4.02] 1.5 15.3 [4.48] 1.5 16.9 [4.95] 1.5 18.6 [5.45] 1.5 20.2 [5.92] 1.6 21.8 [6.39] 1.6 23.4 [6.86] 1.6 25.1 [7.36] 1.6 8.7 [2.55] 1.4 10.4 [3.05] 1.5 12.0 [3.52] 1.5 13.6 [3.99] 1.5 15.2 [4.45] 1.5 16.8 [4.92] 1.5 18.4 [5.39] 1.6 20.0 [5.86] 1.6 21.7 [6.36] 1.6 23.3 [6.83] 1.6 24.9 [7.30] 1.6 8.0 [2.34] 1.6 9.6 [2.81] 1.6 11.3 [3.31] 1.6 12.9 [3.78] 1.6 14.5 [4.25] 1.7 16.2 [4.75] 1.7 17.8 [5.22] 1.7 19.4 [5.69] 1.7 21.1 [6.18] 1.7 22.7 [6.65] 1.8 24.4 [7.15] 1.8 7.9 [2.32] 1.6 9.6 [2.81] 1.6 11.2 [3.28] 1.6 12.8 [3.75] 1.7 14.4 [4.22] 1.7 16.1 [4.72] 1.7 17.7 [5.19] 1.7 19.3 [5.66] 1.7 20.9 [6.13] 1.8 22.6 [6.62] 1.8 24.2 [7.09] 1.8 7.9 [2.32] 1.6 9.5 [2.78] 1.6 11.1 [3.25] 1.7 12.7 [3.72] 1.7 14.3 [4.19] 1.7 15.9 [4.66] 1.7 17.6 [5.16] 1.7 19.2 [5.63] 1.8 20.8 [6.10] 1.8 22.4 [6.56] 1.8 24.0 [7.03] 1.8 6.5 [1.90] 1.8 8.2 [2.40] 1.8 9.8 [2.87] 1.9 11.5 [3.37] 1.9 13.1 [3.84] 1.9 14.7 [4.31] 1.9 16.4 [4.81] 1.9 18.0 [5.28] 2.0 19.6 [5.74] 2.0 21.3 [6.24] 2.0 22.9 [6.71] 2.0 6.5 [1.90] 1.8 8.1 [2.37] 1.9 9.8 [2.87] 1.9 11.4 [3.34] 1.9 13.0 [3.81] 1.9 14.6 [4.28] 1.9 16.3 [4.78] 2.0 17.9 [5.25] 2.0 19.5 [5.71] 2.0 21.1 [6.18] 2.0 22.8 [6.68] 2.0 6.5 [1.90] 1.9 8.1 [2.37] 1.9 9.7 [2.84] 1.9 11.3 [3.31] 1.9 12.9 [3.78] 1.9 14.5 [4.25] 2.0 16.1 [4.72] 2.0 17.8 [5.22] 2.0 19.4 [5.69] 2.0 21.0 [6.15] 2.1 22.6 [6.62] 2.1 [ ] Designates Metric Conversions Air Gross Systems Performance Data RQPL Series COOLING PERFORMANCE DATA—RQPL-025 ENTERING INDOOR AIR @ 80°F [26.7°C] dbE ➀ wbE CFM [L/s] DR ➀ 930 [439] .15 71°F [21.7°C] 850 [401] .17 760 [359] .19 930 [439] .15 67°F [19.4°C] 850 [401] .17 760 [359] .19 930 [439] .15 63°F [17.2°C] 850 [401] .17 760 [359] .19 Total BTUH [kW] 75 Sens BTUH [kW] [23.9] Power 30.4 [8.9] 18.8 [5.5] 1.5 29.9 [8.8] 17.5 [5.1] 1.4 29.3 [8.6] 16.1 [4.7] 1.4 28.5 [8.4] 22.1 [6.5] 1.5 28.0 [8.2] 20.7 [6.1] 1.5 27.5 [8.1] 19.2 [5.6] 1.4 26.8 [7.9] 24.4 [7.2] 1.5 26.4 [7.7] 23.0 [6.8] 1.5 25.9 [7.6] 21.4 [6.3] 1.4 Total BTUH [kW] 80 Sens BTUH [kW] [26.7] Power 29.6 [8.7] 18.2 [5.3] 1.5 29.1 [8.5] 16.9 [5.0] 1.5 28.5 [8.4] 15.5 [4.6] 1.5 27.7 [8.1] 21.5 [6.3] 1.5 27.2 [8.0] 20.1 [5.9] 1.5 26.7 [7.8] 18.6 [5.5] 1.5 26.0 [7.6] 23.8 [7.0] 1.6 25.6 [7.5] 22.4 [6.6] 1.5 25.1 [7.4] 20.8 [6.1] 1.5 Total BTUH [kW] 85 Sens BTUH [kW] [29.4] Power 28.7 [8.4] 17.5 [5.1] 1.6 28.2 [8.3] 16.3 [4.8] 1.6 27.6 [8.1] 14.9 [4.4] 1.6 26.8 [7.9] 20.9 [6.1] 1.6 26.3 [7.7] 19.5 [5.7] 1.6 25.8 [7.6] 18.1 [5.3] 1.6 25.1 [7.4] 23.2 [6.8] 1.6 24.7 [7.2] 21.8 [6.4] 1.6 24.2 [7.1] 20.2 [5.9] 1.6 Total BTUH [kW] 90 Sens BTUH [kW] [32.2] Power Total BTUH [kW] 95 Sens BTUH [kW] [35] Power Total BTUH [kW] 100 Sens BTUH [kW] [37.8] Power 27.7 [8.1] 16.9 [5.0] 1.7 27.2 [8.0] 15.7 [4.6] 1.7 26.7 [7.8] 14.4 [4.2] 1.7 25.8 [7.6] 20.3 [6.0] 1.7 25.4 [7.4] 19.0 [5.6] 1.7 24.9 [7.3] 17.6 [5.2] 1.7 24.1 [7.1] 22.4 [6.6] 1.7 23.7 [6.9] 21.1 [6.2] 1.7 23.3 [6.8] 19.7 [5.8] 1.7 26.7 [7.8] 16.3 [4.8] 1.8 26.2 [7.7] 15.1 [4.4] 1.8 25.7 [7.5] 13.9 [4.1] 1.8 24.8 [7.3] 19.6 [5.8] 1.8 24.4 [7.2] 18.4 [5.4] 1.8 23.9 [7.0] 17.0 [5.0] 1.8 23.1 [6.8] 21.9 [6.4] 1.8 22.7 [6.7] 20.6 [6.0] 1.8 22.3 [6.5] 19.2 [5.6] 1.8 25.6 [7.5] 15.8 [4.6] 1.9 25.2 [7.4] 14.7 [4.3] 1.9 24.7 [7.2] 13.5 [4.0] 1.9 23.7 [6.9] 19.0 [5.6] 1.9 23.3 [6.8] 17.8 [5.2] 1.9 22.9 [6.7] 16.5 [4.8] 1.9 22.0 [6.4] 21.3 [6.3] 1.9 21.7 [6.4] 20.1 [5.9] 1.9 21.3 [6.2] 18.7 [5.5] 1.9 Total BTUH [kW] 105 Sens BTUH [kW] [40.6] Power 24.5 [7.2] 15.2 [4.5] 2.0 24.1 [7.1] 14.2 [4.2] 2.0 23.6 [6.9] 13.0 [3.8] 2.0 22.6 [6.6] 18.5 [5.4] 2.0 22.2 [6.5] 17.3 [5.1] 2.0 21.8 [6.4] 16.1 [4.7] 2.0 20.9 [6.1] 20.8 [6.1] 2.0 20.6 [6.0] 19.6 [5.8] 2.0 20.2 [5.9] 18.3 [5.4] 2.0 Total BTUH [kW] 110 Sens BTUH [kW] °F [43.3] Power [°C] Total BTUH [kW] 115 Sens BTUH [kW] [46.1] Power 23.3 [6.8] 14.7 [4.3] 2.2 22.1 [6.5] 14.2 [4.2] 2.3 22.9 [6.7] 13.7 [4.0] 2.1 21.7 [6.4] 13.2 [3.9] 2.3 22.5 [6.6] 12.6 [3.7] 2.1 21.3 [6.2] 12.2 [3.6] 2.2 21.4 [6.3] 18.0 [5.3] 2.2 20.2 [5.9] 17.5 [5.1] 2.3 21.0 [6.2] 16.8 [4.9] 2.1 19.8 [5.8] 16.4 [4.8] 2.3 20.6 [6.0] 15.6 [4.6] 2.1 19.4 [5.7] 15.2 [4.5] 2.2 19.7 [5.8] 19.7 [5.8] 2.2 18.5 [5.4] 18.5 [5.4] 2.3 19.4 [5.7] 19.1 [5.6] 2.1 18.2 [5.3] 18.2 [5.3] 2.3 19.0 [5.6] 17.8 [5.2] 2.1 17.8 [5.2] 17.4 [5.1] 2.2 O U T D O O R D R Y B U L B T E M P E R A T U R E DR —Depression ratio dbE —Entering air dry bulb wbE —Entering air wet bulb Total —Total capacity x 1000 BTUH Sens —Sensible capacity x 1000 BTUH Power —KW input NOTES: ➀ When the entering air dry bulb is other than 80°F [27°C], adjust the sensible capacity from the table by adding [1.10 x CFM x (1 – DR) x (dbE – 80)]. HEATING PERFORMANCE DATA—RQPL-025 IDB CFM [L/s] O U T D O O R D R Y B U L B T E M P E R A T U R E °F] [°C] 0 [-17.8] 5 [-15] 10 [-12.2] 15 [-9.4] 20 [-6.7] 25 [-3.9] 30 [-1.1] 35 [1.7] 40 [4.4] 45 [7.2] 50 [10] Total BTUH [kW] Power Total BTUH [kW] Power Total BTUH [kW] Power Total BTUH [kW] Power Total BTUH [kW] Power Total BTUH [kW] Power Total BTUH [kW] Power Total BTUH [kW] Power Total BTUH [kW] Power Total BTUH [kW] Power Total BTUH [kW] Power IDB—Indoor air dry bulb 930 [439] 60°F [15.5°C] 850 [401] 760 [359] 930 [439] 70°F [21.1°C] 850 [401] 760 [359] 930 [439] 80°F [26.7°C] 850 [401] 760 [359] 7.3 [2.1] 1.2 9.1 [2.7] 1.3 11.0 [3.2] 1.3 12.8 [3.8] 1.3 14.6 [4.3] 1.4 16.5 [4.8] 1.4 18.3 [5.4] 1.4 20.1 [5.9] 1.4 22.0 [6.4] 1.5 23.8 [7.0] 1.5 25.7 [7.5] 1.5 7.2 [2.1] 1.3 9.1 [2.7] 1.3 10.9 [3.2] 1.3 12.7 [3.7] 1.3 14.5 [4.2] 1.4 16.4 [4.8] 1.4 18.2 [5.3] 1.4 20.0 [5.9] 1.5 21.8 [6.4] 1.5 23.7 [6.9] 1.5 25.5 [7.5] 1.6 7.2 [2.1] 1.3 9.0 [2.6] 1.3 10.8 [3.2] 1.3 12.6 [3.7] 1.4 14.4 [4.2] 1.4 16.2 [4.7] 1.4 18.0 [5.3] 1.4 19.9 [5.8] 1.5 21.7 [6.4] 1.5 23.5 [6.9] 1.5 25.3 [7.4] 1.6 5.9 [1.7] 1.4 7.8 [2.3] 1.4 9.6 [2.8] 1.5 11.4 [3.3] 1.5 13.3 [3.9] 1.5 15.1 [4.4] 1.6 17.0 [5.0] 1.6 18.8 [5.5] 1.6 20.6 [6.0] 1.6 22.5 [6.6] 1.7 24.3 [7.1] 1.7 5.9 [1.7] 1.4 7.7 [2.3] 1.5 9.5 [2.8] 1.5 11.4 [3.3] 1.5 13.2 [3.9] 1.6 15.0 [4.4] 1.6 16.8 [4.9] 1.6 18.7 [5.5] 1.6 20.5 [6.0] 1.7 22.3 [6.5] 1.7 24.1 [7.1] 1.7 5.9 [1.7] 1.4 7.7 [2.3] 1.5 9.5 [2.8] 1.5 11.3 [3.3] 1.5 13.1 [3.8] 1.6 14.9 [4.4] 1.6 16.7 [4.9] 1.6 18.5 [5.4] 1.7 20.3 [5.9] 1.7 22.1 [6.5] 1.7 23.9 [7.0] 1.8 4.6 [1.3] 1.6 6.4 [1.9] 1.6 8.2 [2.4] 1.7 10.1 [3.0] 1.7 11.9 [3.5] 1.7 13.8 [4.0] 1.7 15.6 [4.6] 1.8 17.4 [5.1] 1.8 19.3 [5.7] 1.8 21.1 [6.2] 1.9 22.9 [6.7] 1.9 4.5 [1.3] 1.6 6.4 [1.9] 1.6 8.2 [2.4] 1.7 10.0 [2.9] 1.7 11.8 [3.5] 1.7 13.7 [4.0] 1.8 15.5 [4.5] 1.8 17.3 [5.1] 1.8 19.1 [5.6] 1.9 21.0 [6.2] 1.9 22.8 [6.7] 1.9 4.5 [1.3] 1.6 6.3 [1.8] 1.7 8.1 [2.4] 1.7 9.9 [2.9] 1.7 11.8 [3.5] 1.8 13.6 [4.0] 1.8 15.4 [4.5] 1.8 17.2 [5.0] 1.8 19.0 [5.6] 1.9 20.8 [6.1] 1.9 22.6 [6.6] 1.9 [ ] Designates Metric Conversions 19 Air Gross Systems Performance Data RQPL Series COOLING PERFORMANCE DATA—RQPL-030 ENTERING INDOOR AIR @ 80°F [26.7°C] dbE ➀ wbE CFM [L/s] DR ➀ O U T D O O R D R Y B U L B T E M P E R A T U R E 71°F [21.7°C] 1050 [496] .13 940 [444] .11 1160 [547] .15 67°F [19.4°C] 1050 [496] .13 940 [444] .11 1160 [547] .15 63°F [17.2°C] 1050 [496] .13 940 [444] .11 Total BTUH [kW] 36.9 [10.81] 75 Sens BTUH [kW] 23.7 [6.95] [23.9] 1.9 Power 36.2 [10.61] 22.6 [6.62] 1.9 35.5 [10.40] 21.5 [6.30] 1.9 34.9 [10.23] 26.9 [7.88] 1.9 34.2 [10.02] 25.7 [7.53] 1.9 33.6 [9.85] 24.5 [7.18] 1.9 33.5 [9.82] 28.4 [8.32] 1.9 32.9 [9.64] 27.1 [7.94] 1.9 32.3 [9.47] 25.8 [7.56] 1.9 Total BTUH [kW] 35.7 [10.46] 80 Sens BTUH [kW] 23.1 [6.77] [26.7] 2.0 Power 35.1 [10.29] 22.0 [6.45] 2.0 34.4 [10.08] 21.0 [6.15] 2.0 33.7 [9.88] 26.3 [7.71] 2.0 33.1 [9.70] 25.2 [7.39] 2.0 32.5 [9.52] 24.0 [7.03] 2.0 32.3 [9.47] 27.8 [8.15] 2.0 31.8 [9.32] 26.5 [7.77] 2.0 31.2 [9.14] 25.3 [7.41] 2.0 Total BTUH [kW] 34.6 [10.14] 85 Sens BTUH [kW] 22.5 [6.59] [29.4] 2.1 Power 33.9 [9.94] 21.5 [6.30] 2.1 33.3 [9.76] 20.5 [6.01] 2.1 32.6 [9.55] 25.8 [7.56] 2.1 32.0 [9.38] 24.6 [7.21] 2.1 31.4 [9.20] 23.5 [6.89] 2.1 31.2 [9.14] 27.2 [7.97] 2.1 30.6 [8.97] 26.0 [7.62] 2.1 30.1 [8.82] 24.8 [7.27] 2.1 Total BTUH [kW] 90 Sens BTUH [kW] [32.2] Power Total BTUH [kW] 95 Sens BTUH [kW] [35] Power Total BTUH [kW] 100 Sens BTUH [kW] [37.8] Power 33.4 [9.79] 21.9 [6.42] 2.2 32.8 [9.61] 20.9 [6.13] 2.2 32.2 [9.44] 20.0 [5.86] 2.2 31.4 [9.20] 25.2 [7.39] 2.2 30.9 [9.06] 24.1 [7.06] 2.2 30.3 [8.88] 23.0 [6.74] 2.2 30.1 [8.82] 26.6 [7.80] 2.2 29.5 [8.65] 25.4 [7.44] 2.2 29.0 [8.50] 24.3 [7.12] 2.2 32.3 [9.47] 21.4 [6.27] 2.3 31.7 [9.29] 20.4 [5.98] 2.3 31.1 [9.11] 19.5 [5.71] 2.3 30.3 [8.88] 24.7 [7.24] 2.3 29.8 [8.73] 23.6 [6.92] 2.3 29.2 [8.56] 22.5 [6.59] 2.2 28.9 [8.47] 26.1 [7.65] 2.3 28.4 [8.32] 24.9 [7.30] 2.3 27.9 [8.18] 23.8 [6.98] 2.3 31.1 [9.11] 20.8 [6.10] 2.4 30.6 [8.97] 19.9 [5.83] 2.4 30.0 [8.79] 19.0 [5.57] 2.4 29.1 [8.53] 24.1 [7.06] 2.4 28.6 [8.38] 23.0 [6.74] 2.4 28.1 [8.24] 22.0 [6.45] 2.3 27.8 [8.15] 25.5 [7.47] 2.4 27.3 [8.00] 24.4 [7.15] 2.4 26.8 [7.85] 23.3 [6.83] 2.4 Total BTUH [kW] 30.0 [8.79] 105 Sens BTUH [kW] 20.3 [5.95] [40.6] 2.5 Power 29.4 [8.62] 19.4 [5.69] 2.5 28.9 [8.47] 18.5 [5.42] 2.5 28.0 [8.21] 23.6 [6.92] 2.5 27.5 [8.06] 22.5 [6.59] 2.5 27.0 [7.91] 21.5 [6.30] 2.4 26.6 [7.80] 25.0 [7.33] 2.5 26.1 [7.65] 23.9 [7.00] 2.5 25.6 [7.50] 22.8 [6.68] 2.5 28.2 [8.26] 18.8 [5.51] 2.6 26.9 [7.88] 18.3 [5.36] 2.7 27.7 [8.12] 18.0 [5.28] 2.6 26.4 [7.74] 17.5 [5.13] 2.7 26.7 [7.83] 23.0 [6.74] 2.6 25.4 [7.44] 22.5 [6.59] 2.7 26.2 [7.68] 22.0 [6.45] 2.6 25.0 [7.33] 21.5 [6.30] 2.6 25.8 [7.56] 21.0 [6.15] 2.5 24.5 [7.18] 20.5 [6.01] 2.6 25.4 [7.44] 24.4 [7.15] 2.6 24.1 [7.06] 23.9 [7.00] 2.7 24.9 [7.30] 23.4 [6.86] 2.6 23.6 [6.92] 22.8 [6.68] 2.7 24.5 [7.18] 22.3 [6.54] 2.6 23.2 [6.80] 21.8 [6.39] 2.7 Total BTUH [kW] 110 Sens BTUH [kW] °F [43.3] Power [°C] Total BTUH [kW] 115 Sens BTUH [kW] [46.1] Power DR —Depression ratio dbE —Entering air dry bulb wbE —Entering air wet bulb 1160 [547] .15 28.7 [8.41] 19.7 [5.77] 2.6 27.4 [8.03] 19.2 [5.63] 2.7 Total —Total capacity x 1000 BTUH Sens —Sensible capacity x 1000 BTUH Power —KW input NOTES: ➀ When the entering air dry bulb is other than 80°F [27°C], adjust the sensible capacity from the table by adding [1.10 x CFM x (1 – DR) x (dbE – 80)]. HEATING PERFORMANCE DATA—RQPL-030 IDB CFM [L/s] O U T D O O R D R Y B U L B T E M P E R A T U R E °F [°C] 0 [-17.8] 5 [-15] 10 [-12.2] 15 [-9.4] 20 [-6.7] 25 [-3.9] 30 [-1.1] 35 [1.7] 40 [4.4] 45 [7.2] 50 [10] Total BTUH [kW] Power Total BTUH [kW] Power Total BTUH [kW] Power Total BTUH [kW] Power Total BTUH [kW] Power Total BTUH [kW] Power Total BTUH [kW] Power Total BTUH [kW] Power Total BTUH [kW] Power Total BTUH [kW] Power Total BTUH [kW] Power IDB—Indoor air dry bulb 20 1160 [547] 60°F [15.5°C] 1050 [496] 940 [444] 1160 [547] 70°F [21.1°C] 1050 [496] 940 [444] 1160 [547] 80°F [26.7°C] 1050 [496] 940 [444] 9.5 [2.78] 1.6 11.5 [3.37] 1.6 13.4 [3.93] 1.6 15.3 [4.48] 1.7 17.2 [5.04] 1.7 19.2 [5.63] 1.7 21.1 [6.18] 1.8 23.0 [6.74] 1.8 24.9 [7.30] 1.8 26.9 [7.88] 1.9 28.8 [8.44] 1.9 9.5 [2.78] 1.6 11.4 [3.34] 1.6 13.3 [3.90] 1.7 15.2 [4.45] 1.7 17.1 [5.01] 1.7 19.0 [5.57] 1.8 20.9 [6.13] 1.8 22.8 [6.68] 1.8 24.8 [7.27] 1.8 26.7 [7.83] 1.9 28.6 [8.38] 1.9 9.4 [2.75] 1.6 11.3 [3.31] 1.6 13.2 [3.87] 1.7 15.1 [4.43] 1.7 17.0 [4.98] 1.7 18.9 [5.54] 1.8 20.8 [6.10] 1.8 22.7 [6.65] 1.8 24.6 [7.21] 1.9 26.5 [7.77] 1.9 28.4 [8.32] 1.9 8.0 [2.34] 1.8 19.9 [2.90] 1.8 11.8 [3.46] 1.9 13.8 [4.04] 1.9 15.7 [4.60] 1.9 17.6 [5.16] 1.9 19.5 [5.71] 2.0 21.5 [6.30] 2.0 23.4 [6.86] 2.0 25.3 [7.41] 2.1 27.2 [7.97] 2.1 7.9 [2.32] 1.8 19.8 [2.87] 1.8 11.8 [3.46] 1.9 13.7 [4.02] 1.9 15.6 [4.57] 1.9 17.5 [5.13] 2.0 19.4 [5.69] 2.0 21.3 [6.24] 2.0 23.2 [6.80] 2.1 25.1 [7.36] 2.1 27.0 [7.91] 2.1 7.9 [2.32] 1.8 19.8 [2.87] 1.9 11.7 [3.43] 1.9 13.6 [3.99] 1.9 15.5 [4.54] 2.0 17.4 [5.10] 2.0 19.3 [5.66] 2.0 21.2 [6.21] 2.1 23.0 [6.74] 2.1 24.9 [7.30] 2.1 26.8 [7.85] 2.2 6.6 [1.93] 2.0 18.5 [2.49] 2.0 10.4 [3.05] 2.1 12.3 [3.60] 2.1 14.3 [4.19] 2.1 16.2 [4.75] 2.2 18.1 [5.30] 2.2 20.0 [5.86] 2.2 22.0 [6.45] 2.3 23.9 [7.00] 2.3 25.8 [7.56] 2.3 6.5 [1.90] 2.0 18.4 [2.46] 2.1 10.3 [3.02] 2.1 12.3 [3.60] 2.1 14.2 [4.16] 2.2 16.1 [4.72] 2.2 18.0 [5.28] 2.2 19.9 [5.83] 2.3 21.8 [6.39] 2.3 23.7 [6.95] 2.3 25.6 [7.50] 2.4 6.5 [1.90] 2.1 18.4 [2.46] 2.1 10.3 [3.02] 2.1 12.2 [3.58] 2.2 14.1 [4.13] 2.2 16.0 [4.69] 2.2 17.9 [5.25] 2.3 19.7 [5.77] 2.3 21.6 [6.33] 2.3 23.5 [6.89] 2.4 25.4 [7.44] 2.4 [ ] Designates Metric Conversions Air Gross Systems Performance Data RQPL Series COOLING PERFORMANCE DATA—RQPL-036 ENTERING INDOOR AIR @ 80°F [26.7°C] dbE ➀ wbE CFM [L/s] DR ➀ O U T D O O R D R Y B U L B T E M P E R A T U R E 71°F [21.7°C] 1250 [590] .19 1120 [528] .17 1380 [651] .21 67°F [19.4°C] 1250 [590] .19 1120 [528] .17 1380 [651] .21 63°F [17.2°C] 1250 [590] .19 1120 [528] .17 Total BTUH [kW] 45.0 [13.19] 75 Sens BTUH [kW] 27.7 [8.12] [23.9] 2.3 Power 44.2 [12.95] 26.5 [7.77] 2.2 43.4 [12.72] 25.3 [7.41] 2.2 42.9 [12.57] 31.8 [9.32] 2.2 42.2 [12.37] 30.4 [8.91] 2.2 41.4 [12.13] 28.9 [8.47] 2.2 41.8 [12.25] 34.2 [10.02] 2.2 41.0 [12.02] 32.6 [9.55] 2.2 40.3 [11.81] 31.1 [9.11] 2.2 Total BTUH [kW] 43.9 [12.87] 80 Sens BTUH [kW] 27.1 [7.94] [26.7] 2.4 Power 43.1 [12.63] 25.9 [7.59] 2.4 42.3 [12.40] 24.7 [7.24] 2.4 41.8 [12.25] 31.2 [9.14] 2.4 41.1 [12.05] 29.8 [8.73] 2.4 40.3 [11.81] 28.4 [8.32] 2.3 40.7 [11.93] 33.5 [9.82] 2.4 39.9 [11.69] 32.0 [9.38] 2.3 39.2 [11.49] 30.5 [8.94] 2.3 Total BTUH [kW] 42.6 [12.48] 85 Sens BTUH [kW] 26.5 [7.77] [29.4] 2.5 Power 41.8 [12.25] 25.3 [7.41] 2.5 41.0 [12.02] 24.1 [7.06] 2.5 40.5 [11.87] 30.5 [8.94] 2.5 39.8 [11.66] 29.1 [8.53] 2.5 39.1 [11.46] 27.8 [8.15] 2.5 39.4 [11.55] 32.9 [9.64] 2.5 38.7 [11.34] 31.4 [9.20] 2.5 37.9 [11.11] 29.9 [8.76] 2.5 Total BTUH [kW] 90 Sens BTUH [kW] [32.2] Power Total BTUH [kW] 95 Sens BTUH [kW] [35] Power Total BTUH [kW] 100 Sens BTUH [kW] [37.8] Power 41.1 [12.05] 25.7 [7.53] 2.7 40.3 [11.81] 24.6 [7.21] 2.7 39.6 [11.61] 23.5 [6.89] 2.6 39.0 [11.43] 29.8 [8.73] 2.7 38.3 [11.22] 28.5 [8.35] 2.6 37.6 [11.02] 27.1 [7.94] 2.6 37.9 [11.11] 32.2 [9.44] 2.6 37.2 [10.90] 30.7 [9.00] 2.6 36.5 [10.70] 29.3 [8.59] 2.6 39.5 [11.58] 25.0 [7.33] 2.8 38.8 [11.37] 23.9 [7.00] 2.8 38.1 [11.17] 22.8 [6.68] 2.8 37.4 [10.96] 29.1 [8.53] 2.8 36.8 [10.79] 27.8 [8.15] 2.8 36.1 [10.58] 26.5 [7.77] 2.8 36.3 [10.64] 31.4 [9.20] 2.8 35.6 [10.43] 30.0 [8.79] 2.8 35.0 [10.26] 28.6 [8.38] 2.7 37.8 [11.08] 24.2 [7.09] 3.0 37.1 [10.87] 23.2 [6.80] 2.9 36.5 [10.70] 22.1 [6.48] 2.9 35.8 [10.49] 28.3 [8.29] 2.9 35.1 [10.29] 27.0 [7.91] 2.9 34.5 [10.11] 25.8 [7.56] 2.9 34.6 [10.14] 30.7 [9.00] 2.9 34.0 [9.96] 29.3 [8.59] 2.9 33.4 [9.79] 27.9 [8.18] 2.9 Total BTUH [kW] 36.1 [10.58] 105 Sens BTUH [kW] 23.4 [6.86] [40.6] 3.1 Power 35.5 [10.40] 22.4 [6.56] 3.1 34.8 [10.20] 21.3 [6.24] 3.1 34.1 [9.99] 27.5 [8.06] 3.1 33.5 [9.82] 26.3 [7.71] 3.1 32.8 [9.61] 25.0 [7.33] 3.0 32.9 [9.64] 29.9 [8.76] 3.1 32.3 [9.47] 28.5 [8.35] 3.0 31.7 [9.29] 27.2 [7.97] 3.0 33.8 [9.91] 21.6 [6.33] 3.2 32.2 [9.44] 20.8 [6.10] 3.4 33.2 [9.73] 20.6 [6.04] 3.2 31.7 [9.29] 19.8 [5.80] 3.3 32.4 [9.50] 26.7 [7.83] 3.2 30.8 [9.03] 25.8 [7.56] 3.4 31.8 [9.32] 25.5 [7.47] 3.2 30.2 [8.85] 24.7 [7.24] 3.3 31.2 [9.14] 24.3 [7.12] 3.2 29.7 [8.70] 23.5 [6.89] 3.3 31.2 [9.14] 29.0 [8.50] 3.2 29.6 [8.67] 28.2 [8.26] 3.4 30.7 [9.00] 27.7 [8.12] 3.2 29.1 [8.53] 26.9 [7.88] 3.3 30.1 [8.82] 26.4 [7.74] 3.2 28.6 [8.38] 25.7 [7.53] 3.3 Total BTUH [kW] 110 Sens BTUH [kW] °F [43.3] Power [°C] Total BTUH [kW] 115 Sens BTUH [kW] [46.1] Power DR —Depression ratio dbE —Entering air dry bulb wbE —Entering air wet bulb 1380 [651] .21 34.4 [10.08] 22.6 [6.62] 3.3 32.8 [9.61] 21.8 [6.39] 3.4 Total —Total capacity x 1000 BTUH Sens —Sensible capacity x 1000 BTUH Power —KW input NOTES: ➀ When the entering air dry bulb is other than 80°F [27°C], adjust the sensible capacity from the table by adding [1.10 x CFM x (1 – DR) x (dbE – 80)]. HEATING PERFORMANCE DATA—RQPL-036 IDB CFM [L/s] O U T D O O R D R Y B U L B T E M P E R A T U R E °F [°C] 0 [-17.8] 5 [-15] 10 [-12.2] 15 [-9.4] 20 [-6.7] 25 [-3.9] 30 [-1.1] 35 [1.7] 40 [4.4] 45 [7.2] 50 [10] Total BTUH [kW] Power Total BTUH [kW] Power Total BTUH [kW] Power Total BTUH [kW] Power Total BTUH [kW] Power Total BTUH [kW] Power Total BTUH [kW] Power Total BTUH [kW] Power Total BTUH [kW] Power Total BTUH [kW] Power Total BTUH [kW] Power IDB—Indoor air dry bulb 1380 [651] 60°F [15.5°C] 1250 [590] 1120 [528] 1380 [651] 70°F [21.1°C] 1250 [590] 1120 [528] 1380 [651] 80°F [26.7°C] 1250 [590] 1120 [528] 11.7 [3.43] 1.8 14.1 [4.13] 1.9 16.6 [4.86] 1.9 19.0 [5.57] 2.0 21.5 [6.30] 2.0 23.9 [7.00] 2.0 26.4 [7.74] 2.1 28.8 [8.44] 2.1 31.3 [9.17] 2.2 33.7 [9.88] 2.2 36.2 [10.61] 2.2 11.6 [3.40] 1.9 14.0 [4.10] 1.9 16.5 [4.84] 1.9 18.9 [5.54] 2.0 21.3 [6.24] 2.0 23.8 [6.98] 2.1 26.2 [7.68] .1 28.6 [8.38] 2.1 31.1 [9.11] 2.2 33.5 [9.82] 2.2 35.9 [10.52] 2.3 11.5 [3.37] 1.9 13.9 [4.07] 1.9 16.3 [4.78] 2.0 18.8 [5.51] 2.0 21.2 [6.21] 2.1 23.6 [6.92] 2.1 26.0 [7.62] 2.1 28.4 [8.32] 2.2 30.8 [9.03] 2.2 33.3 [9.76] 2.3 35.7 [10.46] 2.3 9.6 [2.81] 2.1 12.1 [3.55] 2.1 14.5 [4.25] 2.2 17.0 [4.98] 2.2 19.4 [5.69] 2.3 21.9 [6.42] 2.3 24.3 [7.12] 2.3 26.8 [7.85] 2.4 29.2 [8.56] 2.4 31.7 [9.29] 2.5 34.1 [9.99] 2.5 9.6 [2.81] 2.1 12.0 [3.52] 2.2 14.4 [4.22] 2.2 16.9 [4.95] 2.2 19.3 [5.66] 2.3 21.7 [6.36] 2.3 24.2 [7.09] 2.4 26.6 [7.80] 2.4 29.0 [8.50] 2.4 31.5 [9.23] 2.5 33.9 [9.94] 2.5 9.5 [2.78] 2.1 11.9 [3.49] 2.2 14.3 [4.19] 2.2 16.7 [4.89] 2.3 19.2 [5.63] 2.3 21.6 [6.33] 2.4 24.0 [7.03] 2.4 26.4 [7.74] 2.4 28.8 [8.44] 2.5 31.2 [9.14] 2.5 33.7 [9.88] 2.6 8.3 [2.43] 2.4 10.7 [3.14] 2.4 13.2 [3.87] 2.5 15.6 [4.57] 2.5 18.1 [5.30] 2.5 20.5 [6.01] 2.6 23.0 [6.74] 2.6 25.4 [7.44] 2.7 27.9 [8.18] 2.7 30.3 [8.88] 2.8 32.8 [9.61] 2.8 8.2 [2.40] 2.4 10.6 [3.11] 2.5 13.1 [3.84] 2.5 15.5 [4.54] 2.5 17.9 [5.25] 2.6 20.4 [5.98] 2.6 22.8 [6.68] 2.7 25.2 [7.39] 2.7 27.7 [8.12] 2.7 30.1 [8.82] 2.8 32.5 [9.52] 2.8 8.1 [2.37] 2.4 10.6 [3.11] 2.5 13.0 [3.81] 2.5 15.4 [4.51] 2.6 17.8 [5.22] 2.6 20.2 [5.92] 2.7 22.6 [6.62] 2.7 25.1 [7.36] 2.7 27.5 [8.06] 2.8 29.9 [8.76] 2.8 32.3 [9.47] 2.9 [ ] Designates Metric Conversions 21 Air Gross Systems Performance Data RQPL Series COOLING PERFORMANCE DATA—RQPL-042 ENTERING INDOOR AIR @ 80°F [26.7°C] dbE ➀ wbE CFM [L/s] DR ➀ O U T D O O R D R Y B U L B T E M P E R A T U R E 71°F [21.7°C] 1400 [661] .15 1260 [595] .14 1540 [727] .17 67°F [19.4°C] 1400 [661] .15 1260 [595] .14 1540 [727] .17 63°F [17.2°C] 1400 [661] .15 1260 [595] .14 Total BTUH [kW] 53.9 [5.80] 75 Sens BTUH [kW] 32.2 [9.44] [23.9] 2.9 Power 52.9 [15.50] 30.7 [9.00] 2.9 51.9 [15.21] 29.3 [8.59] 2.9 50.9 [14.92] 37.1 [10.87] 2.9 50.0 [14.65] 35.5 [10.40] 2.9 49.1 [14.39] 33.8 [9.91] 2.9 48.1 [14.10] 39.3 [11.52] 2.9 47.3 [13.86] 37.5 [10.99] 2.9 46.4 [13.60] 35.8 [10.49] 2.9 Total BTUH [kW] 52.0 [15.24] 80 Sens BTUH [kW] 31.3 [9.17] [26.7] 3.1 Power 51.0 [14.95] 29.9 [8.76] 3.1 50.1 [14.68] 28.5 [8.35] 3.1 49.0 [14.36] 36.3 [10.64] 3.1 48.1 [14.10] 34.7 [10.17] 3.1 47.2 [13.83] 33.0 [9.67] 3.0 46.2 [13.54] 38.4 [11.25] 3.1 45.4 [13.31] 36.7 [10.76] 3.1 44.6 [13.07] 35.0 [10.26] 3.0 Total BTUH [kW] 50.3 [14.74] 85 Sens BTUH [kW] 30.5 [8.94] [29.4] 3.3 Power 49.4 [14.48] 29.2 [8.56] 3.2 48.5 [14.21] 27.8 [8.15] 3.2 47.3 [13.86] 35.5 [10.40] 3.3 46.5 [13.63] 33.9 [9.94] 3.2 45.6 [13.36] 32.3 [9.47] 3.2 44.6 [13.07] 37.6 [11.02] 3.2 43.8 [12.84] 35.9 [10.52] 3.2 43.0 [12.60] 34.3 [10.05] 3.2 Total BTUH [kW] 90 Sens BTUH [kW] [32.2] Power Total BTUH [kW] 95 Sens BTUH [kW] [35] Power Total BTUH [kW] 100 Sens BTUH [kW] [37.8] Power 48.7 [14.27] 29.8 [8.73] 3.4 47.9 [14.04] 28.4 [8.32] 3.4 47.0 [13.77] 27.1 [7.94] 3.4 45.8 [13.42] 34.7 [10.17] 3.4 44.9 [13.16] 33.2 [9.73] 3.4 44.1 [12.92] 31.6 [9.26] 3.4 43.0 [12.60] 36.8 [10.79] 3.4 42.2 [12.37] 35.2 [10.32] 3.4 41.5 [12.16] 33.6 [9.85] 3.4 47.2 [13.83] 29.0 [8.50] 3.6 46.4 [13.60] 27.7 [8.12] 3.6 45.5 [13.33] 26.4 [7.74] 3.5 44.2 [12.95] 34.0 [9.96] 3.6 43.4 [12.72] 32.4 [9.50] 3.6 42.7 [12.51] 30.9 [9.06] 3.5 41.5 [12.16] 36.1 [10.58] 3.6 40.7 [11.93] 34.5 [10.11] 3.6 40.0 [11.72] 32.9 [9.64] 3.5 45.6 [13.36] 28.2 [8.26] 3.8 44.8 [13.13] 26.9 [7.88] 3.7 44.0 [12.90] 25.7 [7.53] 3.7 42.6 [12.48] 33.2 [9.73] 3.8 41.9 [12.28] 31.7 [9.29] 3.7 41.1 [12.05] 30.2 [8.85] 3.7 39.9 [11.69] 35.3 [10.35] 3.7 39.2 [11.49] 33.7 [9.88] 3.7 38.5 [11.28] 32.1 [9.41] 3.7 Total BTUH [kW] 43.8 [12.84] 105 Sens BTUH [kW] 27.4 [8.03] [40.6] 3.9 Power 43.0 [12.60] 26.1 [7.65] 3.9 42.3 [12.40] 24.9 [7.30] 3.9 40.8 [11.96] 32.3 [9.47] 3.9 40.1 [11.75] 30.9 [9.06] 3.9 39.4 [11.55] 29.4 [8.62] 3.9 38.1 [11.17] 34.4 [10.08] 3.9 37.4 [10.96] 32.9 [9.64] 3.9 36.7 [10.76] 31.4 [9.20] 3.9 41.0 [12.02] 25.2 [7.39] 4.1 38.6 [11.31] 24.2 [7.09] 4.2 40.2 [11.78] 24.1 [7.06] 4.0 37.9 [11.11] 23.1 [6.77] 4.2 38.8 [11.37] 31.4 [9.20] 4.1 36.3 [10.64] 30.3 [8.88] 4.3 38.1 [11.17] 30.0 [8.79] 4.1 35.6 [10.43] 29.0 [8.50] 4.2 37.4 [10.96] 28.6 [8.38] 4.0 35.0 [10.26] 27.6 [8.09] 4.2 36.0 [10.55] 33.5 [9.82] 4.1 33.5 [9.82] 32.4 [9.50] 4.3 35.4 [10.37] 32.0 [9.38] 4.1 32.9 [9.64] 31.0 [9.09] 4.2 34.7 [10.17] 30.5 [8.94] 4.0 32.3 [9.47] 29.5 [8.65] 4.2 Total BTUH [kW] 110 Sens BTUH [kW] °F [43.3] Power [°C] Total BTUH [kW] 115 Sens BTUH [kW] [46.1] Power DR —Depression ratio dbE —Entering air dry bulb wbE —Entering air wet bulb 1540 [727] .17 41.7 [12.22] 26.4 [7.74] 4.1 39.3 [11.52] 25.4 [7.44] 4.3 Total —Total capacity x 1000 BTUH Sens —Sensible capacity x 1000 BTUH Power —KW input NOTES: ➀ When the entering air dry bulb is other than 80°F [27°C], adjust the sensible capacity from the table by adding [1.10 x CFM x (1 – DR) x (dbE – 80)]. HEATING PERFORMANCE DATA—RQPL-042 IDB CFM [L/s] O U T D O O R D R Y B U L B T E M P E R A T U R E °F [°C] 0 [-17.8] 5 [-15] 10 [-12.2] 15 [-9.4] 20 [-6.7] 25 [-3.9] 30 [-1.1] 35 [1.7] 40 [4.4] 45 [7.2] 50 [10] Total BTUH [kW] Power Total BTUH [kW] Power Total BTUH [kW] Power Total BTUH [kW] Power Total BTUH [kW] Power Total BTUH [kW] Power Total BTUH [kW] Power Total BTUH [kW] Power Total BTUH [kW] Power Total BTUH [kW] Power Total BTUH [kW] Power IDB—Indoor air dry bulb 22 1540 [727] 60°F [15.5°C] 1400 [661] 1260 [595] 1540 [727] 70°F [21.1°C] 1400 [661] 1260 [595] 1540 [727] 80°F [26.7°C] 1400 [661] 1260 [595] 13.9 [4.07] 2.6 16.9 [4.95] 2.6 20.0 [5.86] 2.6 23.0 [6.74] 2.7 26.0 [7.62] 2.7 29.0 [8.50] 2.8 32.0 [9.38] 2.8 35.1 [10.29] 2.8 38.1 [11.17] 2.9 41.1 [12.05] 2.9 44.1 [12.92] 2.9 13.8 [4.04] 2.6 16.8 [4.92] 2.6 19.8 [5.80] 2.7 22.8 [6.68] 2.7 25.8 [7.56] 2.7 28.8 [8.44] 2.8 31.8 [9.32] 2.8 34.8 [10.20] 2.9 37.8 [11.08] 2.9 40.8 [11.96] 2.9 43.8 [12.84] 3.0 13.7 [4.02] 2.6 16.7 [4.89] 2.7 19.7 [5.77] 2.7 22.6 [6.62] 2.7 25.6 [7.50] 2.8 28.6 [8.38] 2.8 31.6 [9.26] 2.9 34.6 [10.14] 2.9 37.5 [10.99] 2.9 40.5 [11.87] 3.0 43.5 [12.75] 3.0 12.9 [3.78] 3.0 16.0 [4.69] 3.0 19.0 [5.57] 3.1 22.0 [6.45] 3.1 25.0 [7.33] 3.1 28.0 [8.21] 3.2 31.1 [9.11] 3.2 34.1 [9.99] 3.2 37.1 [10.87] 3.3 40.1 [11.75] 3.3 43.1 [12.63] 3.4 12.8 [3.75] 3.0 15.8 [4.63] 3.1 18.8 [5.51] 3.1 21.8 [6.39] 3.1 24.8 [7.27] 3.2 27.8 [8.15] 3.2 30.8 [9.03] 3.2 33.8 [9.91] 3.3 36.8 [10.79] 3.3 39.8 [11.66] 3.4 42.8 [12.54] 3.4 12.8 [3.75] 3.1 15.7 [4.60] 3.1 18.7 [5.48] 3.1 21.7 [6.36] 3.2 24.7 [7.24] 3.2 27.6 [8.09] 3.3 30.6 [8.97] 3.3 33.6 [9.85] 3.3 36.6 [10.73] 3.4 39.5 [11.58] 3.4 42.5 [12.46] 3.4 11.2 [3.28] 3.3 14.2 [4.16] 3.4 17.3 [5.07] 3.4 20.3 [5.95] 3.5 23.3 [6.83] 3.5 26.3 [7.71] 3.5 29.3 [8.59] 3.6 32.4 [9.50] 3.6 35.4 [10.37] 3.6 38.4 [11.25] 3.7 41.4 [12.13] 3.7 11.1 [3.25] 3.4 14.1 [4.13] 3.4 17.1 [5.01] 3.5 20.1 [5.89] 3.5 23.1 [6.77] 3.5 26.1 [7.65] 3.6 29.1 [8.53] 3.6 32.1 [9.41] 3.6 35.1 [10.29] 3.7 38.1 [11.17] 3.7 41.1 [12.05] 3.8 11.1 [3.25] 3.4 14.0 [4.10] 3.5 17.0 [4.98] 3.5 20.0 [5.86] 3.5 23.0 [6.74] 3.6 25.9 [7.59] 3.6 28.9 [8.47] 3.7 31.9 [9.35] 3.7 34.9 [10.23] 3.7 37.9 [11.11] 3.8 40.8 [11.96] 3.8 [ ] Designates Metric Conversions Air Gross Systems Performance Data RQPL Series COOLING PERFORMANCE DATA—RQPL-048 ENTERING INDOOR AIR @ 80°F [26.7°C] dbE ➀ wbE CFM [L/s] DR ➀ O U T D O O R D R Y B U L B T E M P E R A T U R E 71°F [21.7°C] 1600 [755] .13 1440 [680] .11 1760 [831] .15 67°F [19.4°C] 1600 [755] .13 1440 [680] .11 1760 [831] .15 63°F [17.2°C] 1600 [755] .13 1440 [680] .11 Total BTUH [kW] 60.4 [17.70] 75 Sens BTUH [kW] 37.4 [10.96] [23.9] 3.2 Power 59.3 [17.38] 35.7 [10.46] 3.1 58.3 [17.09] 34.1 [9.99] 3.1 57.1 [16.73] 42.7 [12.51] 3.1 56.1 [16.44] 40.8 [11.96] 3.1 55.0 [16.12] 38.9 [11.40] 3.1 54.5 [15.97] 45.0 [13.19] 3.1 53.5 [15.68] 43.0 [12.60] 3.1 52.5 [15.39] 41.0 [12.02] 3.1 Total BTUH [kW] 58.8 [17.23] 80 Sens BTUH [kW] 36.6 [10.73] [26.7] 3.4 Power 57.8 [16.94] 35.0 [10.26] 3.3 56.7 [16.62] 33.3 [9.76] 3.3 55.5 [16.27] 41.9 [12.28] 3.3 54.5 [15.97] 40.0 [11.72] 3.3 53.5 [15.68] 38.2 [11.20] 3.3 52.9 [15.50] 44.2 [12.95] 3.3 51.9 [15.21] 42.2 [12.37] 3.3 51.0 [14.95] 40.3 [11.81] 3.2 Total BTUH [kW] 57.0 [16.71] 85 Sens BTUH [kW] 35.7 [10.46] [29.4] 3.5 Power 56.0 [16.41] 34.1 [9.99] 3.5 55.0 [16.12] 32.5 [9.52] 3.5 53.7 [15.74] 41.0 [12.02] 3.5 52.7 [15.44] 39.2 [11.49] 3.5 51.8 [15.18] 37.3 [10.93] 3.5 51.1 [14.98] 43.3 [12.69] 3.5 50.2 [14.71] 41.4 [12.13] 3.5 49.3 [14.45] 39.4 [11.55] 3.4 Total BTUH [kW] 90 Sens BTUH [kW] [32.2] Power Total BTUH [kW] 95 Sens BTUH [kW] [35] Power Total BTUH [kW] 100 Sens BTUH [kW] [37.8] Power 55.1 [16.15] 34.8 [10.20] 3.7 54.1 [15.86] 33.2 [9.73] 3.7 53.1 [15.56] 31.7 [9.29] 3.7 51.7 [15.15] 40.1 [11.75] 3.7 50.8 [14.89] 38.3 [11.22] 3.7 49.9 [14.62] 36.5 [10.70] 3.6 49.1 [14.39] 42.4 [12.43] 3.7 48.3 [14.16] 40.5 [11.87] 3.6 47.4 [13.89] 38.6 [11.31] 3.6 53.1 [15.56] 33.8 [9.91] 3.9 52.1 [15.27] 32.3 [9.47] 3.9 51.2 [15.01] 30.8 [9.03] 3.9 49.8 [14.59] 39.1 [11.46] 3.9 48.9 [14.33] 37.4 [10.96] 3.9 48.0 [14.07] 35.6 [10.43] 3.8 47.2 [13.83] 41.4 [12.13] 3.9 46.3 [13.57] 39.6 [11.61] 3.8 45.5 [13.33] 37.7 [11.05] 3.8 51.1 [14.98] 32.9 [9.64] 4.1 50.2 [14.71] 31.4 [9.20] 4.1 49.3 [14.45] 29.9 [8.76] 4.0 47.8 [14.01] 38.2 [11.20] 4.1 46.9 [13.75] 36.5 [10.70] 4.0 46.1 [13.51] 34.8 [10.20] 4.0 45.2 [13.25] 40.5 [11.87] 4.1 44.4 [13.01] 38.7 [11.34] 4.0 43.6 [12.78] 36.9 [10.81] 4.0 Total BTUH [kW] 49.3 [14.45] 105 Sens BTUH [kW] 32.0 [9.38] [40.6] 4.3 Power 48.4 [14.18] 30.6 [8.97] 4.3 47.5 [13.92] 29.2 [8.56] 4.2 46.0 [13.48] 37.3 [10.93] 4.3 45.1 [13.22] 35.7 [10.46] 4.2 44.3 [12.98] 34.0 [9.96] 4.2 43.4 [12.72] 39.6 [11.61] 4.2 42.6 [12.48] 37.9 [11.11] 4.2 41.8 [12.25] 36.1 [10.58] 4.2 46.8 [13.72] 29.9 [8.76] 4.4 45.5 [13.33] 29.3 [8.59] 4.6 45.9 [13.45] 28.5 [8.35] 4.4 44.6 [13.07] 27.9 [8.18] 4.6 44.3 [12.98] 36.6 [10.73] 4.5 43.0 [12.60] 36.0 [10.55] 4.6 43.5 [12.75] 34.9 [10.23] 4.4 42.2 [12.37] 34.4 [10.08] 4.6 42.7 [12.51] 33.3 [9.76] 4.4 41.4 [12.13] 32.8 [9.61] 4.6 41.7 [12.22] 38.9 [11.40] 4.4 40.4 [11.84] 38.3 [11.22] 4.6 41.0 [12.02] 37.1 [10.87] 4.4 39.6 [11.61] 36.6 [10.73] 4.6 40.2 [11.78] 35.4 [10.37] 4.4 38.9 [11.40] 34.8 [10.20] 4.5 Total BTUH [kW] 110 Sens BTUH [kW] °F [43.3] Power [°C] Total BTUH [kW] 115 Sens BTUH [kW] [46.1] Power DR —Depression ratio dbE —Entering air dry bulb wbE —Entering air wet bulb 1760 [831] .15 47.6 [13.95] 31.3 [9.17] 4.5 46.3 [13.57] 30.7 [9.00] 4.7 Total —Total capacity x 1000 BTUH Sens —Sensible capacity x 1000 BTUH Power —KW input NOTES: ➀ When the entering air dry bulb is other than 80°F [27°C], adjust the sensible capacity from the table by adding [1.10 x CFM x (1 – DR) x (dbE – 80)]. HEATING PERFORMANCE DATA—RQPL-048 IDB CFM [L/s] O U T D O O R D R Y B U L B T E M P E R A T U R E °F [°C] 0 [-17.8] 5 [-15] 10 [-12.2] 15 [-9.4] 20 [-6.7] 25 [-3.9] 30 [-1.1] 35 [1.7] 40 [4.4] 45 [7.2] 50 [10] Total BTUH [kW] Power Total BTUH [kW] Power Total BTUH [kW] Power Total BTUH [kW] Power Total BTUH [kW] Power Total BTUH [kW] Power Total BTUH [kW] Power Total BTUH [kW] Power Total BTUH [kW] Power Total BTUH [kW] Power Total BTUH [kW] Power IDB—Indoor air dry bulb 1760 [831] 60°F [15.5°C] 1600 [755] 1440 [680] 1760 [831] 70°F [21.1°C] 1600 [755] 1440 [680] 1760 [831] 80°F [26.7°C] 1600 [755] 1440 [680] 16.9 [4.95] 2.6 20.1 [5.89] 2.6 23.2 [6.80] 2.7 26.4 [7.74] 2.7 29.5 [8.65] 2.8 32.7 [9.58] 2.8 35.9 [10.52] 2.9 39.0 [11.43] 2.9 42.2 [12.37] 3.0 45.3 [13.28] 3.0 48.5 [14.21] 3.1 16.8 [4.92] 2.6 19.9 [5.83] 2.6 23.1 [6.77] 2.7 26.2 [7.68] 2.8 29.3 [8.59] 2.8 32.5 [9.52] 2.9 35.6 [10.43] 2.9 38.7 [11.34] 3.0 41.9 [12.28] 3.0 45.0 [13.19] 3.1 48.1 [14.10] 3.1 16.7 [4.89] 2.6 19.8 [5.80] 2.7 22.9 [6.71] 2.7 26.0 [7.62] 2.8 29.1 [8.53] 2.8 32.2 [9.44] 2.9 35.4 [10.37] 2.9 38.5 [11.28] 3.0 41.6 [12.19] 3.1 44.7 [13.10] 3.1 47.8 [14.01] 3.2 15.4 [4.51] 3.0 18.6 [5.45] 3.0 21.8 [6.39] 3.1 24.9 [7.30] 3.1 28.1 [8.24] 3.2 31.2 [9.14] 3.2 34.4 [10.08] 3.3 37.5 [10.99] 3.3 40.7 [11.93] 3.4 43.9 [12.87] 3.4 47.0 [13.77] 3.5 15.3 [4.48] 3.0 18.5 [5.42] 3.0 21.6 [6.33] 3.1 24.7 [7.24] 3.2 27.9 [8.18] 3.2 31.0 [9.09] 3.3 34.1 [9.99] 3.3 37.3 [10.93] 3.4 40.4 [11.84] 3.4 43.6 [12.78] 3.5 46.7 [13.69] 3.5 15.2 [4.45] 3.0 18.3 [5.36] 3.1 21.5 [6.30] 3.1 24.6 [7.21] 3.2 27.7 [8.12] 3.2 30.8 [9.03] 3.3 33.9 [9.94] 3.4 37.0 [10.84] 3.4 40.1 [11.75] 3.5 43.2 [12.66] 3.5 46.4 [13.60] 3.6 14.4 [4.22] 3.4 17.6 [5.16] 3.5 20.7 [6.07] 3.5 23.9 [7.00] 3.6 27.1 [7.94] 3.6 30.2 [8.85] 3.7 33.4 [9.79] 3.7 36.5 [10.70] 3.8 39.7 [11.63] 3.8 42.8 [12.54] 3.9 46.0 [13.48] 3.9 14.3 [4.19] 3.5 17.5 [5.13] 3.5 20.6 [6.04] 3.6 23.7 [6.95] 3.6 26.9 [7.88] 3.7 30.0 [8.79] 3.7 33.1 [9.70] 3.8 36.3 [10.64] 3.8 39.4 [11.55] 3.9 42.5 [12.46] 3.9 45.7 [13.39] 4.0 14.2 [4.16] 3.5 17.3 [5.07] 3.5 20.4 [5.98] 3.6 23.6 [6.92] 3.7 26.7 [7.83] 3.7 29.8 [8.73] 3.8 32.9 [9.64] 3.8 36.0 [10.55] 3.9 39.1 [11.46] 3.9 42.2 [12.37] 4.0 45.3 [13.28] 4.0 [ ] Designates Metric Conversions 23 24 High Low Low Low (Tap 1) Low (Tap 1) 2.0 [7.03] 2.5 [8.79] 3.0 [10.55] 3.5 [12.31] 4.0 [14.07] 1350 CFM/1700 CFM [496/802 L/s] 1225 CFM/1575 CFM [578/743 L/s] 1050 CFM/1350 CFM [496/637 L/s] 875 CFM/1125 CFM [413/531 L/s] 700 CFM/900 CFM [271/319 L/s] Manufacturer Recommended Air-Flow Range (Min/Max) CFM 10x9 Blower 3/4 HP [559] 2 Speed (X13 Motor) 10x9 Blower 3/4 HP [559] 2 Speed (X13 Motor) 10x9 Blower 1/3 HP [248] 1 Speed (PSC Motor) 10x9 Blower 1/2 HP [372] 2 Speed (PSC Motor) 9x7 Blower 1/4 HP [186] 2 Speed (PSC Motor) Blower Size/ Motor HP [W] & # of Speeds High (Tap 2) Low (Tap 1) High (Tap 2) Low (Tap 1) High High Medium Low High Low Motor Speed [ ] Designates Metric Conversions DOWN DISCHARGE PRESSURE DROP (ADD TO EXTERNAL STATIC PRESSURE) CFM [L/s] 600 [283] 800 [378] Pressure Drop—Inches W.C. [kPa] .00 .01 [.002] NOTE: Effect of electric heat strip on airflow performance is negligible. Motor Speed from Factory Nominal Cooling Capacity Tons [kW] 0.1 [.02] 292 1076 [508] CFM 1514 [715] 895 538 CFM RPM Watts 0.2 [.05] 454 1000 [472] .02 [.005] 966 1770 [835] CFM RPM 390 Watts 923 1675 [791] CFM RPM 321 Watts 870 1559 [736] CFM RPM 268 Watts 824 RPM 1455 [687] CFM Watts 352 355 1200 [566] .03 [.007] 466 989 1751 [826] 401 944 1658 [782] 327 893 1530 [722] 280 856 1431 [675] 805 785 RPM 1201 [567] 514 930 1461 [690] 415 810 1197 [565] 349 775 1059 [500] 278 965 861 [406] 214 785 657 [310] Watts 1222 [577] 423 CFM 765 RPM 1222 [577] Watts CFM 356 940 RPM Watts 730 898 [424] CFM RPM 221 Watts 695 RPM 675 [319] Watts CFM INDOOR AIRFLOW PERFORMANCE—208 VOLTS 1400 [661] .05 [.012] 473 1018 1706 [805] 412 979 1610 [760] 338 932 1488 [702] 288 889 1396 [659] 346 830 1173 [554] 493 965 1415 [668] 407 855 1179 [556] 341 820 1032 [487] 266 995 822 [388] 203 870 634 [299] 0.3 [.07] 1600 [775] .07 [.017] 486 1050 1672 [789] 425 1013 1580 [746] 351 968 1454 [686] 303 931 1360 [642] 340 870 1137 [537] 473 985 1370 [647] 397 890 1162 [548] 331 865 996 [470] 253 1020 777 [367] 191 905 602 [284] 0.4 [.10] 490 1078 1624 [766] 433 1045 1535 [724] 364 1007 1417 [669] 311 968 1315 [621] 331 905 1090 [514] 454 1005 1322 [624] 386 920 1137 [537] 320 905 950 [448] 239 1045 721 [340] 171 940 560 [264] 0.5 [.12] External Static Pressure—Inches W.C. [kPa] Side Discharge—Wet Coil 0.6 [.15] 481 1100 1555 [734] 440 1077 1491 [704] 371 1036 1375 [649] 325 1009 1285 [606] 320 950 1030 [486] 434 1025 1266 [597] 370 960 1097 [518] 305 940 896 [423] 221 1070 651 [307] 163 980 505 [238] 0.7 [.17] 460 1115 1463 [690] 432 1098 1422 [671] 381 1072 1336 [631] 331 1041 1241 [586] 306 990 954 [450] 412 1045 1197 [565] 351 995 1033 [488] 287 975 832 [393] 199 1090 562 [265] 149 1020 435 [205] Air Indoor Airflow Performance RQNL Series High Low High Low (Tap 1) Low (Tap 1) 2.0 [7.03] 2.5 [8.79] 3.0 [10.55] 3.5 [12.31] 4.0 [14.07] 1350 CFM/1700 CFM [496/802 L/s] 1225 CFM/1575 CFM [578/743 L/s] 1050 CFM/1350 CFM [496/637 L/s] 875 CFM/1125 CFM [413/531 L/s] 700 CFM/900 CFM [271/319 L/s] Manufacturer Recommended Air-Flow Range (Min/Max) CFM 10x9 Blower 3/4 HP [559] 2 Speed (X13 Motor) 10x9 Blower 3/4 HP [559] 2 Speed (X13 Motor) 10x9 Blower 1/3 HP [249] 1 Speed (PSC Motor) 10x9 Blower 1/2 HP [373] 3 Speed (PSC Motor) 9x7 Blower 1/4 HP [186] 2 Speed (PSC Motor) Blower Size/ Motor HP [W] & # of Speeds High (Tap 2) Low (Tap 1) High (Tap 2) Low (Tap 1) High High Medium Low High Low Motor Speed [ ] Designates Metric Conversions DOWN DISCHARGE PRESSURE DROP (ADD TO EXTERNAL STATIC PRESSURE) CFM [L/s] 600 [283] 800 [378] Pressure Drop—Inches W.C. [kPa] .00 .01 [.002] NOTE: Effect of electric heat strip on airflow performance is negligible. Motor Speed from Factory Nominal Cooling Capacity Tons [kW] 0.1 [.02] 315 1206 [569] CFM 1641 [774] 980 589 CFM RPM Watts 0.2 [.05] 440 1000 [472] .02 [.005] 955 1748 [825] CFM RPM 404 Watts 931 1692 [799] CFM RPM 317 Watts 867 1550 [732] CFM RPM 276 Watts 831 RPM 1467 [692] CFM Watts 419 428 1200 [566] .03 [.007] 446 978 1718 [811] 409 950 1661 [784] 323 890 1520 [717] 282 854 1439 [679] 875 835 RPM 1357 [640] 565 1000 1577 [744] 498 900 1368 [646] 406 815 1182 [558] 303 1015 922 [435] 242 870 751 [354] Watts 1391 [656] 498 CFM 865 RPM 1411 [666] Watts CFM 419 990 RPM Watts 760 946 [446] CFM RPM 253 Watts 825 RPM 771 [364] Watts CFM INDOOR AIRFLOW PERFORMANCE—230 VOLTS 1400 [661] .05 [.012] 462 1010 1686 [796] 424 982 1633 [771] 339 930 1486 [701] 297 894 1408 [665] 406 915 1312 [619] 543 1020 1515 [715] 481 935 1327 [626] 394 870 1157 [546] 288 1035 882 [416] 230 910 725 [342] 0.3 [.07] 1600 [775] .07 [.017] 475 1043 1647 [777] 434 1018 1589 [750] 355 974 1449 [684] 307 932 1360 [642] 392 940 1258 [594] 523 1035 1455 [687] 464 970 1285 [606] 381 910 1128 [532] 273 1055 830 [392] 217 950 691 [326] 0.4 [.10] 484 1073 1616 [763] 450 1054 1560 [736] 362 1003 1407 [664] 319 972 1331 [628] 378 965 1201 [567] 503 1050 1393 [657] 447 1000 1238 [584] 368 950 1091 [515] 257 1070 769 [363] 204 985 645 [304] 0.5 [.12] External Static Pressure—Inches W.C. [kPa] Side Discharge—Wet Coil 0.6 [.15] 473 1096 1543 [728] 453 1082 1512 [714] 377 1039 1382 [652] 326 1005 1287 [607] 365 985 1145 [540] 481 1065 1329 [627] 431 1020 1183 [558] 353 975 1044 [493] 241 1085 701 [331] 189 1010 584 [276] 0.7 [.17] 459 1111 1472 [695] 443 1103 1442 [681] 385 1073 1337 [631] 341 1042 1259 [594] 355 1000 1093 [516] 456 1080 1262 [596] 391 1035 1116 [527] 334 1000 983 [464] 226 1100 630 [297] 181 1030 546 [258] Air Indoor Airflow Performance RQNL Series 25 26 High (Tap 1) Low (Tap 1) Low (Tap 1) Low (Tap 1) Low (Tap 1) 2.0 [7.03] 2.5 [8.79] 3.0 [10.55] 3.5 [12.31] 4.0 [14.07] 1350 CFM/1700 CFM [496/802 L/s] 1225 CFM/1575 CFM [578/743 L/s] 1050 CFM/1350 CFM [496/637 L/s] 875 CFM/1125 CFM [413/531 L/s] 700 CFM/900 CFM [271/319 L/s] Manufacturer Recommended Air-Flow Range (Min/Max) CFM 10x9 Blower 3/4 HP [559] 2 Speed (X13 Motor) 10x9 Blower 3/4 HP [559] 2 Speed (X13 Motor) 10x9 Blower 1/2 HP [372] 3 Speed (X13 Motor) 10x9 Blower 1/2 HP [372] 3 Speed (X13 Motor) 9x7 Blower 1/3 HP [249] 3 Speed (X13 Motor) Blower Size/ Motor HP [W] & # of Speeds High (Tap 2) Low (Tap 1) High (Tap 2) Low (Tap 1) High (Tap 3) Medium (Tap 2) Low (Tap 1) High (Tap 3) Medium (Tap 2) Low (Tap 1) High (Tap 2) Low (Tap 1) Motor Speed [ ] Designates Metric Conversions 0.1 [.02] 454 1000 [472] .02 [.005] 966 1770 [835] CFM RPM 390 Watts 923 1675 [791] CFM RPM 321 Watts 870 1559 [736] CFM RPM 268 Watts 824 RPM 1455 [687] CFM Watts 280 1200 [566] .03 [.007] 466 989 1751 [826] 401 944 1658 [782] 327 893 1530 [722] 280 856 1431 [675] 898 268 1357 [640] 864 1396 [659] CFM 242 850 RPM 233 1292 [610] 208 819 Watts 820 RPM Watts 1307 [617] 200 CFM 784 RPM 1247 [589] CFM Watts 210 1220 [576] 826 206 1213 [572] 796 1252 [591] CFM 177 785 1132 [534] 145 749 1034 [488] 177 971 887 [419] 147 818 RPM 167 0.2 [.05] 818 [386] Watts 744 RPM Watts 1165 [550] 143 CFM 719 1067 [504] CFM RPM 173 Watts 934 914 [431] CFM RPM 145 Watts 892 RPM 847 [400] Watts CFM DOWN DISCHARGE PRESSURE DROP (ADD TO EXTERNAL STATIC PRESSURE) CFM [L/s] 600 [283] 800 [378] Pressure Drop—Inches W.C. [kPa] .00 .01 [.002] NOTE: Effect of electric heat strip on airflow performance is negligible. Motor Speed from Factory Nominal Cooling Capacity Tons [kW] INDOOR AIRFLOW PERFORMANCE—208 VOLTS 473 1018 0.4 [.10] 486 1050 1672 [789] 425 1013 1580 [746] 351 968 1454 [686] 303 931 1360 [642] 292 942 1286 [607] 255 918 1214 [573] 224 890 1143 [539] 225 893 1137 [537] 191 864 1051 [496] 159 819 957 [452] 186 1053 824 [389] 157 765 765 [361] 1400 [661] .05 [.012] 1706 [805] 412 979 1610 [760] 338 932 1488 [702] 288 889 1396 [659] 288 920 1334 [630] 248 889 1238 [584] 219 863 1178 [556] 219 868 1166 [550] 188 833 1091 [515] 155 791 992 [468] 185 1024 853 [403] 156 788 788 [372] 0.3 [.07] 1600 [775] .07 [.017] 490 1078 1624 [766] 433 1045 1535 [724] 364 1007 1417 [669] 311 968 1315 [621] 299 976 1253 [591] 262 944 1170 [552] 233 932 1099 [519] 234 934 1099 [519] 202 905 1009 [476] 169 876 912 [430] 188 1083 793 [374] 164 737 737 [348] 0.5 [.12] 481 1100 1555 [734] 440 1077 1491 [704] 371 1036 1375 [649] 325 1009 1285 [606] 304 1010 1207 [570] 268 981 1135 [536] 236 957 1064 [502] 245 982 1046 [494] 206 951 959 [453] 182 952 820 [387] 192 1121 762 [360] 167 695 695 [328] 0.6 [.15] External Static Pressure—Inches W.C. [kPa] Side Discharge—Wet Coil 0.7 [.17] 460 1115 1463 [690] 432 1098 1422 [671] 381 1072 1336 [631] 331 1041 1241 [586] 310 1043 1163 [549] 277 1028 1087 [513] 246 1012 998 [471] 248 1026 986 [465] 217 1020 855 [404] 185 983 778 [367] 185 1135 717 [338] 167 659 659 [311] 0.8 [.20] 316 1089 1103 [521] 284 1087 989 [467] 256 1075 904 [427] 256 1086 892 [421] 351 1053 819 [387] 192 1024 729 [344] 164 1155 602 [284] 155 581 581 [274] Air Indoor Airflow Performance RQPL Series Low (Tap 1) Low (Tap 1) Low (Tap 1) Low (Tap 1) Low (Tap 1) 2.0 [7.03] 2.5 [8.79] 3.0 [10.55] 3.5 [12.31] 4.0 [14.07] 1350 CFM/1700 CFM [496/802 L/s] 1225 CFM/1575 CFM [578/743 L/s] 1050 CFM/1350 CFM [496/637 L/s] 875 CFM/1125 CFM [413/531 L/s] 700 CFM/900 CFM [271/319 L/s] Manufacturer Recommended Air-Flow Range (Min/Max) CFM 10x9 Blower 3/4 HP [559] 2 Speed (X13 Motor) 10x9 Blower 3/4 HP [559] 2 Speed (X13 Motor) 10x9 Blower 1/2 HP [372] 3 Speed (X13 Motor) 10x9 Blower 1/2 HP [372] 3 Speed (X13 Motor) 9x7 Blower 1/3 HP [249] 3 Speed (X13 Motor) Blower Size/ Motor HP [W] & # of Speeds High (Tap 2) Low (Tap 1) High (Tap 2) Low (Tap 1) High (Tap 3) Medium (Tap 2) Low (Tap 1) High (Tap 3) Medium (Tap 2) Low (Tap 1) High (Tap 2) Low (Tap 1) Motor Speed 27 [ ] Designates Metric Conversions 0.1 [.02] 440 1000 [472] .02 [.005] 955 1748 [825] CFM RPM 404 Watts 931 1692 [799] CFM RPM 317 Watts 867 1550 [732] CFM RPM 276 Watts 831 RPM 1467 [692] CFM Watts 290 1200 [566] .03 [.007] 446 978 1718 [811] 409 950 1661 [784] 323 890 1520 [717] 282 854 1439 [679] 898 285 1379 [651] 874 1416 [668] CFM 249 867 RPM 239 1298 [613] 217 829 Watts 821 RPM Watts 1336 [631] 210 CFM 802 RPM 1258 [594] CFM Watts 217 1215 [573] 836 212 1223 [577] 797 1271 [600] CFM 182 799 1124 [530] 148 753 1041 [491] 184 988 888 [419] 159 953 RPM 176 0.2 [.05] 834 [394] Watts 762 RPM Watts 1187 [560] 144 CFM 715 1076 [508] CFM RPM 181 Watts 953 918 [433] CFM RPM 151 Watts 889 RPM 862 [407] Watts CFM DOWN DISCHARGE PRESSURE DROP (ADD TO EXTERNAL STATIC PRESSURE) CFM [L/s] 600 [283] 800 [378] Pressure Drop—Inches W.C. [kPa] .00 .01 [.002] NOTE: Effect of electric heat strip on airflow performance is negligible. Motor Speed from Factory Nominal Cooling Capacity Tons [kW] INDOOR AIRFLOW PERFORMANCE—230 VOLTS 462 1010 0.4 [.10] 475 1043 1647 [777] 434 1018 1589 [750] 355 974 1449 [684] 307 932 1360 [642] 304 952 1292 [610] 262 920 1229 [580] 230 894 1160 [547] 231 905 1137 [537] 196 859 1071 [505] 169 825 970 [458] 198 1060 838 [395] 166 1018 781 [369] 1400 [661] .05 [.012] 1686 [796] 424 982 1633 [771] 339 930 1486 [701] 297 894 1408 [665] 299 933 1342 [633] 259 903 1259 [594] 225 861 1200 [566] 227 878 1169 [552] 191 832 1096 [517] 157 787 1017 [480] 194 1032 874 [412] 162 974 819 [387] 0.3 [.07] 1600 [775] .07 [.017] 484 1073 1616 [778] 450 1054 1560 [736] 362 1003 1407 [664] 319 972 1331 [628] 314 993 1275 [602] 275 957 1198 [565] 239 933 1130 [533] 241 939 1104 [521] 209 914 1024 [483] 175 877 928 [438] 200 1091 819 [387] 173 1065 761 [359] 0.5 [.12] 473 1096 1543 [779] 453 1082 1512 [714] 377 1039 1382 [652] 326 1005 1287 [607] 322 1011 1240 [585] 279 993 1160 [547] 245 971 1082 [511] 247 974 1071 [505] 212 940 987 [466] 187 946 852 [402] 204 1126 781 [369] 176 1101 729 [344] 0.6 [.15] External Static Pressure—Inches W.C. [kPa] Side Discharge—Wet Coil 0.7 [.17] 459 1111 1472 [780] 443 1103 1442 [681] 385 1073 1337 [631] 341 1042 1259 [594] 328 1060 1200 [566] 290 1038 1116 [527] 259 1020 1026 [484] 257 1026 1015 [479] 227 1021 896 [423] 198 1005 785 [370] 189 1146 711 [336] 180 1133 695 [328] 0.8 [.20] 337 1091 1168 [551] 299 1071 1071 [505] 268 1077 954 [450] 270 1089 934 [441] 235 1059 852 [402] 202 1032 745 [352] 168 1157 616 [291] 165 1156 606 [286] Air Indoor Airflow Performance RQPL Series Air Electrical Data RQNL/RQPL Series Unit Information ELECTRICAL DATA – RQNL- SERIES -B024JK -B030JK -B036CK -B036JK -B042CK -B042JK -B048CK -B048JK Unit Operating Voltage Range 187-253 187-253 187-253 187-253 187-253 187-253 187-253 187-253 Minimum Circuit Ampacity 19/19 22/22 17/17 24/24 25/25 33/33 26/26 37/37 25/25 25/25 20/20 25/25 30/30 35/35 30/30 40/40 30/30 35/35 25/25 40/40 35/35 50/50 35/35 50/50 1 208/230 1 2 3450 12.8/12.8 58.3/58.3 1 208/230 1 1/5 1.3 2.2 1 208/230 1 1/4 1.5 2.4 1 208/230 1 2 1/2 3450 14.1/14.1 73/73 1 208/230 1 1/5 1.3 2.2 1 208/230 1 1/2 2.4 5.1 1 208/230 3 3 3450 10.4/10.4 88/88 1 208/230 1 1/5 1.3 2.2 1 208/230 1 1/3 1.7 2.5 1 208/230 1 3 3450 16.7/16.7 79/79 1 208/230 1 1/5 1.3 2.2 1 208/230 1 1/3 1.7 2.5 1 208/230 3 3 1/2 3450 13.1/13.1 83.1/83.1 1 208/230 1 1/3 2 3.9 1 208/230 1 3/4 6 0 1 208/230 1 3 1/2 3450 19.9/19.9 109/109 1 208/230 1 1/3 2 3.9 1 208/230 1 3/4 6 0 1 208/230 3 4 3450 13.7/13.7 83.1/83.1 1 208/230 1 1/3 2 3.9 1 208/230 1 3/4 6 0 1 208/230 1 4 3450 23.8/23.8 117/117 1 208/230 1 1/3 2 3.9 1 208/230 1 3/4 6 0 Evaporator Fan Condenser Motor Compressor Motor Minimum Overcurrent Protection Device Size Maximum Overcurrent Protection Device Size No. Volts Phase HP RPM Amps (RLA) Amps (LRA) No. Volts Phase HP Amps (FLA) Amps (LRA) No. Volts Phase HP Amps (FLA) Amps (LRA) Unit Information ELECTRICAL DATA – RQPL- SERIES -B024JK B025JK -B030JK -B036CK -B036JK -B042CK -B042JK -B048CK -B048JK Unit Operating Voltage Range 187-253 187-253 187-253 187-253 187-253 187-253 187-253 187-253 187-253 Minimum Circuit Ampacity 21/21 21/21 24/24 19/19 27/27 25/25 33/33 26/26 37/37 25/25 25/25 25/25 20/20 30/30 30/30 35/35 30/30 40/40 30/30 30/30 35/35 25/25 40/40 35/35 50/50 35/35 50/50 1 208/230 1 2 3450 12.8/12.8 58.3/58.3 1 208/230 1 1/5 1.3 2.2 1 208/230 1 1/3 2.8 0 1 208/230 1 2 3450 12.8/12.8 58.3/58.3 1 208/230 1 1/3 1.3/1.3 0/0 1 208/230 1 1/3 2.8/2.8 0/0 1 208/230 1 2 1/2 3450 14.1/14.1 73/73 1 208/230 1 1/5 1.3 2.2 1 208/230 1 1/2 4.1 0 1 208/230 3 3 3450 10.4/10.4 88/88 1 208/230 1 1/5 1.3 2.2 1 208/230 1 1/2 4.1 0 1 208/230 1 3 3450 16.7/16.7 79/79 1 208/230 1 1/5 1.3 2.2 1 208/230 1 1/2 4.1 0 1 208/230 3 3 1/2 3450 13.1/13.1 83.1/83.1 1 208/230 1 1/3 2 3.9 1 208/230 1 3/4 6 0 1 208/230 1 3 1/2 3450 19.9/19.9 109/109 1 208/230 1 1/3 2 3.9 1 208/230 1 3/4 6 0 1 208/230 3 4 3450 13.7/13.7 83.1/83.1 1 208/230 1 1/3 2 3.9 1 208/230 1 3/4 6 0 1 208/230 1 4 3450 23.8/23.8 117/117 1 208/230 1 1/3 2 3.9 1 208/230 1 3/4 6 0 Evaporator Fan Condenser Motor Compressor Motor Minimum Overcurrent Protection Device Size Maximum Overcurrent Protection Device Size No. Volts Phase HP RPM Amps (RLA) Amps (LRA) No. Volts Phase HP Amps (FLA) Amps (LRA) No. Volts Phase HP Amps (FLA) Amps (LRA) 1. Horsepower Per Compressor. 2. Amp Draw Per Motor. Multiply Value By Number of Motors to Determine Total Amps. 28 Air Unit Model Application Electric Heater Kits RQNL/RQPL Series Electric Heater Kit Models RXQJ-A05J (208-240 volt, 1-ph, 5kW) RXQJ-A10J (208-240 volt, 1-ph, 10kW) RQNL/RQPL-B024JK & RQPL-B025JK RXQJ-A05J (208-240 volt, 1-ph, 5kW) RXQJ-A10J (208-240 volt, 1-ph, 10kW) RXQJ-A10J (208-240 volt, 1-ph, 10kW) RXQJ-A15J (208-240 volt, 1-ph, 15kW) RQNL/RQPL-B030JK RQNL/RQPL-B036JK RXQJ-10J (208-240 volt, 1-ph, 10kW) RQNL/RQPL-B042JK RXQJ-15J (208-240 volt, 1-ph, 15kW) RXQJ-10J (208-240 volt, 1-ph, 10kW) RXQJ-15J (208-240 volt, 1-ph, 15kW) RXQJ-A10C (208-240 volt, 3-ph, 10kW) RXQJ-A15C (208-240 volt, 3-ph, 15kW) RQNL/RQPL-B048JK RQNL/RQPL-B036CK RXQJ-A10C (208-240 volt, 3-ph, 10kW) RQNL/RQPL-B042CK RXQJ-A15C (208-240 volt, 3-ph, 15kW) RXQJ-A10C (208-240 volt, 3-ph, 10kW) RXQJ-A15C (208-240 volt, 3-ph, 15kW) RQNL/RQPL-B048CK WARNING ONLY ELECTRIC HEATER KITS SUPPLIED BY THIS MANUFACTURER AS DESCRIBED IN THIS PUBLICATION HAVE BEEN DESIGNED, TESTED, AND EVALUATED BY A NATIONALLY RECOGNIZED SAFETY TESTING AGENCY FOR USE WITH THIS UNIT. USE OF ANY OTHER MANUFACTURED ELECTRIC HEATERS INSTALLED WITHIN THIS UNIT MAY CAUSE HAZARDOUS CONDITIONS RESULTING IN PROPERTY DAMAGE, FIRE, BODILY INJURY OR DEATH. 29 30 B048CK B042CK B036CK Unit Model No. RQNL- B048JK B042JK B036JK B030JK B024JK Unit Model No. RQNL- No Heat A10C A15C No Heat A10C A15C No Heat A10C A15C — 1 2 — 1 2 — 2 2 — 2 2 — 2 2 No. of Sequence Steps — 3.6/4.8 7.2/9.6 — 3.6/4.8 7.2/9.6 — 7.2/9.6 10.8/14.4 — 7.2/9.6 10.8/14.4 — 7.2/9.6 10.8/14.4 24.56/32.75 36.84/49.13 24.56/32.75 36.84/49.13 24.56/32.75 36.84/49.13 12.28/16.38 24.56/32.75 — 12.28/16.38 24.56/32.75 — 17.3/20.0 34.6/40.0 — 17.3/20.0 34.6/40.0 — 34.6/40.0 51.9/60.0 — 34.6/40.0 51.9/60.0 — 34.6/40.0 51.9/60.0 Rated Heater Heater Heater kW KBTU/Hr Amp. @ 208-240 V @ 208-240 V @ 208-240 V 19/19 41/44 62/69 22/22 43/47 65/72 24/24 68/74 89/99 33/33 77/83 98/108 37/37 80/87 102/112 Unit Min. Ckt. Ampacity @ 208-240 V Min./Max. @ 208 V 30/30 45/50 70/70 35/35 50/50 70/80 40/40 70/80 90/100 50/50 80/90 100/110 50/50 90/90 110/125 Min./Max. @ 240 V 30/30 45/50 70/70 35/35 50/50 70/80 40/40 70/80 90/100 50/50 80/90 100/110 50/50 90/90 110/125 Over Current Protective Device Size Heat Pump — 22/25 44/50 — 22/25 44/50 — 44/50 65/75 — 44/50 65/75 — 44/50 65/75 Min. Ckt. Ampacity 208/240V — 25/25 45/50 — 25/25 45/50 — 45/50 70/80 — 45/50 70/80 — 45/50 70/80 Max. Fuse Size 208/240V Heater Kit 19/19 — — 22/22 — — 24/24 — — 33/33 — — 37/37 — — Min. Circuit Ampacity 208-240 V Min./Max. @ 208 V 30/30 — — 35/35 — — 40/40 — — 50/50 — — 50/50 — — — 3 3 — 3 3 — 3 3 — 3 3 — 3 3 — 3 3 No. of Sequence Steps — 7.2/9.6 10.8/14.4 — 7.2/9.6 10.8/14.4 — 7.2/9.6 10.8/14.4 24.56/32.75 36.84/49.13 24.56/32.75 36.84/49.13 24.56/32.75 36.84/49.13 — 20.0/23.1 30.1/34.7 — 20.0/23.1 30.1/34.7 — 20.0/23.1 30.1/34.7 Rated Heater Heater Heater kW KBTU/Hr Amp. @ 208-240 V @ 208-240 V @ 208-240 V Heater Kit 17/17 42/45 54/60 25/25 50/54 63/68 26/26 51/55 63/69 Unit Min. Ckt. Ampacity @ 208-240 V Single Power Supply For Both Unit and Heater Kit Min./Max. @ 208 V 25/25 45/45 60/60 35/35 50/60 70/70 35/35 60/60 70/70 Min./Max. @ 240 V 25/25 45/45 60/60 35/35 50/60 70/70 35/35 60/60 70/70 Over Current Protective Device Size Heat Pump — 25/29 38/44 — 25/29 38/44 — 25/29 38/44 Min. Ckt. Ampacity 208/240V — 25/30 40/45 — 25/30 40/45 — 25/30 40/45 Max. Fuse Size 208/240V Heater Kit 17/17 — — 25/25 — — 26/26 — — Min. Circuit Ampacity 208-240 V Min./Max. @ 208 V 25/25 — — 35/35 — — 35/35 — — Min./Max. @ 240 V 25/25 — — 35/35 — — 35/35 — — Over Current Protective Device Size Heat Pump Separate Power Supply For Both Unit and Heater Kit Min./Max. @ 240 V 30/30 — — 35/35 — — 40/40 — — 50/50 — — 50/50 — — Over Current Protective Device Size Heat Pump Separate Power Supply For Both Unit and Heater Kit 208-240 VOLT, THREE PHASE, 60 HZ, AUXILIARY ELECTRIC HEATER KITS CHARACTERISTICS AND APPLICATION — 1 2 — 1 2 — 2 3 — 2 3 — 2 3 RXQJNo. of Heater Kit Elements Nominal kW No Heat A05J A10J No Heat A05J A10J No Heat A10J A15J No Heat B10J B15J No Heat B10J B15J RXQJNo. of Heater Kit Elements Nominal kW Heater Kit Single Power Supply For Both Unit and Heater Kit 208-240 VOLT, SINGLE PHASE, 60 HZ, AUXILIARY ELECTRIC HEATER KITS CHARACTERISTICS AND APPLICATION Air Electric Heater Kits RQNL Series B048CK B042CK B036CK Unit Model No. RQPL- B048JK B042JK B036JK B030JK B024JK B025JK Unit Model No. RQPL- No Heat A10C A15C No Heat A10C A15C No Heat A10C A15C — 1 2 — 1 2 — 2 2 — 2 2 — 2 2 No. of Sequence Steps — 3.6/4.8 7.2/9.6 — 3.6/4.8 7.2/9.6 — 7.2/9.6 10.8/14.4 — 7.2/9.6 10.8/14.4 — 7.2/9.6 10.8/14.4 24.56/32.75 36.84/49.13 24.56/32.75 36.84/49.13 24.56/32.75 36.84/49.13 12.28/16.38 24.56/32.75 — 12.28/16.38 24.56/32.75 — 17.3/20.0 34.6/40.0 — 17.3/20.0 34.6/40.0 — 34.6/40.0 51.9/60.0 — 34.6/40.0 51.9/60.0 — 34.6/40.0 51.9/60.0 Rated Heater Heater Heater kW KBTU/Hr Amp. @ 208-240 V @ 208-240 V @ 208-240 V 21/21 42/46 64/71 24/24 45/49 67/74 27/27 70/77 92/102 33/33 77/83 98/108 37/37 80/87 102/112 Unit Min. Ckt. Ampacity @ 208-240 V Min./Max. @ 208 V 30/30 50/50 70/80 35/35 50/50 70/80 40/40 70/80 100/110 50/50 80/90 100/110 50/50 90/90 110/125 Min./Max. @ 240 V 30/30 50/50 70/80 35/35 50/50 70/80 40/40 70/80 100/110 50/50 80/90 100/110 50/50 90/90 110/125 Over Current Protective Device Size Heat Pump — 22/25 44/50 — 22/25 44/50 — 44/50 65/75 — 44/50 65/75 — 44/50 65/75 Min. Ckt. Ampacity 208/240V — 25/25 45/50 — 25/25 45/50 — 45/50 70/80 — 45/50 70/80 — 45/50 70/80 Max. Fuse Size 208/240V Heater Kit 21/21 — — 24/24 — — 27/27 — — 33/33 — — 37/37 — — Min. Circuit Ampacity 208-240 V Min./Max. @ 208 V 30/30 — — 35/35 — — 40/40 — — 50/50 — — 50/50 — — — 3 3 — 3 3 — 3 3 — 3 3 — 3 3 — 3 3 No. of Sequence Steps — 7.2/9.6 10.8/14.4 — 7.2/9.6 10.8/14.4 — 7.2/9.6 10.8/14.4 24.56/32.75 36.84/49.13 24.56/32.75 36.84/49.13 24.56/32.75 36.84/49.13 — 20.0/23.1 30.1/34.7 — 20.0/23.1 30.1/34.7 — 20.0/23.1 30.1/34.7 Rated Heater Heater Heater kW KBTU/Hr Amp. @ 208-240 V @ 208-240 V @ 208-240 V Heater Kit 19/19 44/48 57/62 25/25 50/54 63/68 26/26 51/55 63/69 Unit Min. Ckt. Ampacity @ 208-240 V Single Power Supply For Both Unit and Heater Kit Min./Max. @ 208 V 25/25 45/50 60/70 35/35 50/60 70/70 35/35 60/60 70/70 Min./Max. @ 240 V 25/25 45/50 60/70 35/35 50/60 70/70 35/35 60/60 70/70 Over Current Protective Device Size Heat Pump — 25/29 38/44 — 25/29 38/44 — 25/29 38/44 Min. Ckt. Ampacity 208/240V — 25/30 40/45 — 25/30 40/45 — 25/30 40/45 Max. Fuse Size 208/240V Heater Kit 19/19 — — 25/25 — — 26/26 — — Min. Circuit Ampacity 208-240 V Min./Max. @ 208 V 25/25 — — 35/35 — — 35/35 — — Min./Max. @ 240 V 25/25 — — 35/35 — — 35/35 — — Over Current Protective Device Size Heat Pump Separate Power Supply For Both Unit and Heater Kit Min./Max. @ 240 V 30/30 — — 35/35 — — 40/40 — — 50/50 — — 50/50 — — Over Current Protective Device Size Heat Pump Separate Power Supply For Both Unit and Heater Kit 208-240 VOLT, THREE PHASE, 60 HZ, AUXILIARY ELECTRIC HEATER KITS CHARACTERISTICS AND APPLICATION — 1 2 — 1 2 — 2 3 — 2 3 — 2 3 RXQJNo. of Heater Kit Elements Nominal kW No Heat A05J A10J No Heat A05J A10J No Heat A10J A15J No Heat B10J B15J No Heat B10J B15J RXQJNo. of Heater Kit Elements Nominal kW Heater Kit Single Power Supply For Both Unit and Heater Kit 208-240 VOLT, SINGLE PHASE, 60 HZ, AUXILIARY ELECTRIC HEATER KITS CHARACTERISTICS AND APPLICATION Air Electric Heater Kits RQPL Series 31 Air Dimensional Data RQNL/RQPL Series OUTDOOR FAN GRILLE AND COMPRESSOR ACCESS CONTROL ACCESS PANEL FILTER ACCESS PANEL (FOR UNIT MOUNTED FILTER ACCESSORY) LIQUID PRESSURE SERVICE PORT OUTDOOR COIL PROTECTIVE GRILLE 30% 2% SUCTION PRESSURE SERVICE PORT 21% 2% THREADED PVC CONDENSATE DRAIN CONNECTION (3/4" [19.05 mm] N.P.T.) THERMOSTAT WIRING ENTRANCE 29% 2% ELECTRICAL POWER ENTRANCE CORNER WEIGHTS % OF TOTAL UNIT WEIGHT 20% 2% SIDE RETURN DUCT OPENING BLOWER/ EVAPORATOR ACCESS PANEL TOP VIEW SIDE SUPPLY DUCT OPENING BOTTOM VIEW 451/16" [1145 mm] INSIDE 19 47 /32" [1209 mm] 13/16" [30 mm] TYP. 11/2" [38 mm] TYP. BOTTOM RETURN DUCT OPENING 5013/16" [1290 mm] 497/16" [1256 mm] INSIDE BOTTOM SUPPLY DUCT OPENING 141/4" [362 mm] TYP. 199/16" [497 mm] OUTDOOR FAN GRILLE & COMPRESSOR ACCESS [ ] Designates Metric Conversions 32 313/16" [97 mm] 45/16" [95 mm] 153/8" [391 mm] 33/16" [97 mm] Dimensional Data RQNL/RQPL Series Air SIDE VIEW SIDE VIEW OUTDOOR COIL PROTECTIVE GRILLE FILTER ACCESS PANEL (FOR UNIT MOUNTED FILTER ACCESSORY) THERMOSTAT WIRE ENTRANCE 11/8" [28.6 mm] 255/16" [643 mm] 103/16" [259 mm] 51/16" [129 mm] 43/4" [121 mm] ELECTRICAL POWER ENTRANCE 527/16" [1332 mm] BLOWER/ EVAPORATOR ACCESS PANEL BACK VIEW FRONT VIEW CONTROL ACCESS PANEL 47/8" [124 mm] SIDE SUPPLY DUCT OPENING LIQUID PRESSURE SERVICE PORT 133/4" [349 mm] 75/16" [186 mm] 57/16" [138 mm] 21/2" [63.5 mm] 81/2" [216 mm] TYP. 2211/16" [576 mm] 47/16" [113 mm] 471/2" [1207 mm] THREADED PVC CONDENSATED DRAIN CONNECTION (3/4 N.P.T.) 15" [381 mm] 143/16" [360 mm] TYP. 191/8" [486 mm] SIDE RETURN DUCT OPENING SHOWN WITH DUCT COVERS REMOVED. SUCTION PRESSURE SERVICE PORT IMPORTANT: INSTALLATION MUST NOT INTERFERE WITH DRAINAGE OPENINGS IN BOTTOM OF UNIT UNDER OUTDOOR COIL. Model Number Height “A” B024, B025 3515/16 B030, B036, B042, B048 41 IMPORTANT: UNIT MUST BE LEVEL TO PREVENT WATER MIGRATION. [ ] Designates Metric Conversions 33 Air Typical Installations RQNL/RQPL Series [ ] Designates Metric Conversions 34 Air Accessories RQNL/RQPL Series ACCESSORY EQUIPMENT Accessory Description Thermostats Model Application RQNL-/RQPL- Accessory Model No. See Thermostat Specification Sheet (T11-001) Roofcurb RQNL-/RQPL- RXQG-AAA14 (14" [356 mm] Height) RXQG-AAA24 (24" [610 mm] Height) Supply & Return Diffusers RQNL-/RQPL- RXRN-BD15 Economizers (Downflow Only) RQNL-/RQPL- Economizers (Sideflow Only) RQNL-/RQPL- Fresh Air Damper RQNL-/RQPL- AXRF-FAB1 (Motorized-35%) AXRF-FAA1 (Fixed-35%) Rectangular to Round Transition (Downflow) RQNL-/RQPL- RXMC-CA02 (16" [406 mm] Ducts) RXMC-CA03 (18" [457 mm] Ducts) Filter Kit High Pressure Control Outdoor Thermostat RQNL-/RQPLRQNL-/RQPLRQNL-/RQPL- RXRY-B01 RXAB-D01 RXPT-A01 Low Amient Control RQNL-/RQPL- RXPZ-G01 Duct Adapter Sideflow Square to Round Transition Lift Kit RQNL-/RQPLRQNL-/RQPL- AXMC-BA01 RXML-A01 AXRE-CAA30 (3 Position) AXRD-CAM10 (Fully Modulating) AXRD-CCM10 (Fully Modulating) AXRE-CCA30 (3 Position) COMMON SUPPLY/RETURN CONCENTRIC AIR DIFFUSER SUPPLY/RETURN DIFFUSER NOTE: The location of the combination supply and return diffuser should not exceed 10 feet [3.05 m] above the floor level for units @ 1000 CFM [472 L/s] or less and 12 [3.66 m] to 14 feet [4.27 m] above the floor level for units with CFM greater than 1000 [472 L/s]. If the diffuser is installed with a greater distance than recommended above, the supply air may become stratified above the required comfort area causing uncomfortable conditions. AIRFLOW/PRESSURE DROP INFORMATION (INCHES W.C. [kPa]) Designed to convert a side by side or an over and under arrangement into a concentric distribution of air. The diffuser is flush mounted, completely insulated, assembled, and internally baffled to provide four way supply air distribution with a center return. To make the assembly complete and ready to fit into a 2' [0.61 m] x 4' [1.22 m] suspended ceiling grid, the diffuser includes adjustable supply louvers, hanging rings, anti-sweat gasket, and round flanges for use with flexible ducts. Approximate CFM [L/s]-Supply Air 1300 [614] 1575 [743] 1800 [850] 2200 [1038] Plenum & Supply/Return Duct .07 [.017] .10 [.024] .12 [.030] .17 [.042] Diffuser .09 [.022] .13 [.032] .16 [.040] .24 [.060] Economizer .06 [.015] .09 [.022] .11 [.027] .17 [.042] Accessory SUPPLY AIR/PERFORMANCE Model No. RXRNBD15 Diameter Inches [mm] 16 [406] Shipping Wt. Lbs. [kg] 90 [40.82] Dimension A Inches [mm] 201/2 [521] Diffuser Airflow CFM [L/s] 800 [378]-1200 [566] 1600 [755]-2000 [944] Range of Throw Ft. [m] 14 [4.27]-16 [4.88] 18 [5.49]-28 [8.53] [ ] Designates Metric Conversions 35 Air Accessories RQNL/RQPL Series THERMOSTATS 200-Series * Programmable 300-Series * Deluxe Programmable 400-Series * Special Applications/ Programmable * Photos are representative. Actual models may vary. For detailed thermostat match-up information, see specification sheet form number T11-001. 36 500-Series * Communicating/ Programmable Air Accessories RQNL/RQPL Series DUCT ADAPTERS RECTANGULAR TO ROUND TRANSITIONS (DOWNFLOW) RXMC-CA02 RXMC-CA03 [ ] Designates Metric Conversions 37 Air Accessories RQNL/RQPL Series FRESH AIR DAMPER FOR USE ON RQNL-/RQPL- SERIES AXRF-FAA1 (Fixed - 0-35%) The 0-35% manual outside Air Damper is designed to replace the unit return air duct cover. No drilling or damper assembly is required. The amount of outside air (0-35%) is controlled by simply adjusting the side damper. AXRF-FAB1 (Motorized - 0-35%) The 0-35% motorized outside Air Damper is designed to replace the unit return air duct cover. No drilling or damper assembly is required. The control motor opens the adjustable slide damper when the unit blower motor is energized. ECONOMIZERS AXRE-CAA30 (3 Position) and AXRD-CAM10 (Fully Modulating) for RQNL-/RQPL- Series Downflow Application AXRE-CAA30 (3 Position) Provided with enthalpy control, and mixed air sensor. Settings include fully open, fully closed and adjustable mid point. AXRD-CAM10 (Fully Modulating) Provided with enthalpy control, mixed air sensor and minimum position potentiometer for proportioning (modulating) the amount of fresh air. [ ] Designates Metric Conversions 38 Air Accessories RQNL/RQPL Series ECONOMIZERS AXRD-CCM10 (Fully Modulating) and AXRE-CCA30 (3 Position) Horizontal Application AXRD-CCM10 (Fully Modulating) Provided with enthalpy control, mixed air sensor and minimum position potentiometer for proportioning (modulating) the amount of fresh air. AXRE-CCA30 (3-Position) Has outdoor air sensor, minimum position potentiometer, and mixed air sensor to provide three damper positions. [ ] Designates Metric Conversions 39 Air Accessories RQNL/RQPL Series FILTER KIT INSTALLATION RXRY-B01 For use in either vertical or horizontal discharge. Minimum Airflow 510 [241] 680 [321] 850 [401] 1020 [481] 1190 [562] 1275 [602] 1700 [802] CFM [L/s] Nominal Airflow 600 [283] 800 [378] 1000 [472] 1200 [566] 1400 [661] 1500 [708] 2000 [944] [ ] Designates Metric Conversions 40 Maximum Airflow 660 [311] 880 [415] 1100 [519] 1320 [623] 1540 [727] 1650 [779] 2200 [1039] Airflow Pressure Drop, Inches W.C. [kPa] CFM [L/s] 1" Filter 2" Filter 500 [236] .02 [.0050] .03 [.0075] 600 [283] .02 [.0050] .03 [.0075] 700 [330] .03 [.0075] .04 [.0010] 800 [378] .04 [.0010] .05 [.0124] 900 [425] .05 [.0124] .06 [.0149] 1000 [472] .07 [.0174] .08 [.0199] 1100 [519] .08 [.0199] .09 [.0224] 1200 [566] .10 [.0249] .12 [.0299] 1300 [614] .13 [.0324] .15 [.0373] 1400 [661] .16 [.0398] .19 [.0473] 1500 [708] .19 [.0473] .21 [.0523] 1600 [755] .20 [.0498] .23 [.0572] 1700 [802] .21 [.0523] .24 [.0598] 1800 [850] .22 [.0548] .25 [.0623] 1900 [897] .24 [.0598] .27 [.0672] 2000 [944] .26 [.0647] .29 [.0722] Air Accessories RQNL/RQPL Series DUCT ADAPTER SIDEFLOW SQUARE TO ROUND TRANSITION AXMC-BA01 Adapts the side rectangular supply and return openings to 14" [356 mm] diameter round openings. Adapters provided with same finish as unit and also provided with thermal insulation. [ ] Designates Metric Conversions 41 Air Accessories RQNL/RQPL Series Roofcurb (Sloped) RXQG-AAA14 & RXQG-AAA24 for RQNL-/RQPL- Series RXQG-AAA14 (14" [356 mm] High) Note: Heat pump models must use sloped curbs. Hinged corners make for fast, easy set-up. RXQG-AAA24 (24" [610 mm] High) Packaged Heat Pump Roofcurb Installation (Sloped) OUTDOOR FAN GRILLE� AND COMPRESSOR ACCESS OUTDOOR COIL� PROTECTIVE GRILLE 5"� [127 mm] IMPORTANT: UNIT MUST BE LEVEL TO � PREVENT WATER MIGRATION LIQUID PRESSURE� SERVICE PORT SUCTION PRESSURE� SERVICE PORT 207/8" [530.2 mm] THREADED PVC CONDENSATE� DRAIN CONNECTION (3/4" [19.05 mm] N.P.T.) CONTROL� ACCESS PANEL [ ] Designates Metric Conversions 42 Air Accessories RQNL/RQPL Series ROOFCURB ADAPTERS Fabricated from galvanized steel to adapt the New cabinet to the old style curb. All are furnished with a New gasket. OLD MODEL PACKAGE HEAT PUMP OLD CURB MODEL SMALL CABINET (11/2-2 TON) [5.28-7.03 kW] RPNCRPND- 20 SERIES RXPA-CA20 MEDIUM CABINET (21/2-3 TON) [8.79-10.55 kW] RPNCRPND- 21 SERIES RXPA-CA21 EXTRA LARGE CABINET (31/2-5 TON) [12.31-17.58 kW] RPNCRPND- 23 SERIES RXPA-CA23 NEW MODEL TO OLD MODEL ROOFCURB ADAPTER NEW MODEL PACKAGE HEAT PUMP ONLY 1 CABINET SIZE— ALL MODELS RXPX-BACCA20 RXPX-BACCA21 RXPX-BCCCA23 RQNL-/ RQPL- [ ] Designates Metric Conversions 43 Air 44 Wiring Diagrams RQNL Series Air Wiring Diagrams RQNL Series 45 Air 46 Wiring Diagrams RQNL Series Air Wiring Diagrams RQNL Series 47 Air 48 Wiring Diagrams RQNL Series Air Limited Warranty RQNL/RQPL Series BEFORE PURCHASING THIS APPLIANCE, READ IMPORTANT ENERGY COST AND EFFICIENCY INFORMATION AVAILABLE FROM YOUR RETAILER. GENERAL TERMS OF LIMITED WARRANTY* Rheem will furnish a replacement for any part of this product which fails in normal use and service within the applicable periods stated, in accordance with the terms of the limited warranty. *For Complete Details of the Limited Warranty, Including Applicable Terms and Conditions, See Your Local Installer or Contact the Manufacturer for a Copy. Conditional Parts (Registration Required) 1 Phase, Residential Applications ..................Ten (10) Years Compressor 1 Phase, Residential Applications...................Ten (10) Years 1 & 3 Phase, Commercial Applications ...........Five (5) Years Parts 1 & 3 Phase, Commercial Applications .............One (1) Year 49 Air 50 Notes RQNL/RQPL Series Air Notes RQNL/RQPL Series 51 The new degree of comfort.™ In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice. Rheem Heating, Cooling & Water Heating • P.O. Box 17010 Fort Smith, Arkansas 72917 • www.rheem.com Rheem Canada Ltd./Ltée • 125 Edgeware Road, Unit 1 Brampton, Ontario • L6Y 0P5 PRINTED IN U.S.A 02/12 QG FORM NO. P11-791
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes Create Date : 2012:02:20 16:42:58-06:00 Modify Date : 2012:02:24 16:47:51-06:00 Has XFA : No XMP Toolkit : Adobe XMP Core 4.2.1-c041 52.342996, 2008/05/07-20:48:00 Metadata Date : 2012:02:24 16:47:51-06:00 Producer : Acrobat Distiller 9.5.0 (Macintosh) Format : application/pdf Title : untitled Document ID : uuid:b372a69f-72be-f54e-ac5e-8cbd73879b22 Instance ID : uuid:029ccd5a-17a2-44a5-a98e-48160b7bb26d Page Count : 52EXIF Metadata provided by EXIF.tools