Rheem Classic Series Package Heat Pump Submittal Sheet
Rheem-Classic-Series-Package-Heat-Pump-Submittal-Sheet-684028 rheem-classic-series-package-heat-pump-submittal-sheet-684028
2015-04-02
: Rheem Rheem-Classic-Series-Package-Heat-Pump-Submittal-Sheet-684025 rheem-classic-series-package-heat-pump-submittal-sheet-684025 rheem pdf
Open the PDF directly: View PDF .
Page Count: 3
PROJECT NAME ______________________________________________________________________________
LOCATION __________________________________________________________________________________
ARCHITECT__________________________________________________________________________________
ENGINEER __________________________________________________________________________________
CONTRACTOR ______________________________________________________________________________
SUBMITTED BY ______________________________ DATE ________________________________________
UNIT SUMMARY
SUBMITTAL COVER SHEET
Quantity
Unit Designation
Model No.
Total Cooling
Sensible Cooling
Air Ent. Evaporator
Air Lvg. Evaporator
Heating Input
Heating Output
CFM/ESP
EER/SEER
Electrical
Minimum Ampacity
Min.-Max. Breaker
Net Unit Weight
Accessory
Catalog Form Number
ACCESSORIES: NOTES:
PRINTED IN U.S.A. 10-06 DC FORM NO. X11-1123 REV. 2
Supersedes Form No. X11-1123 Rev. 1
SUBMITTAL SHEET FOR PACKAGE HEAT PUMPS
FEATURING EARTH-FRIENDLY R-410A REFRIGERANT:
RQNL- HIGH EFFICIENCY 13 SEER SERIES
RQPL- HIGH EFFICIENCY 14 SEER SERIES
Nominal Sizes 2 Thru 4 Tons [7.03 thru 14.07 kW]
[ ] Designates Metric Conversions
FORM NO. X33-1234 REV. 1
Supersedes Form No. X33-1234
UNIT DATA
COOLING PERFORMANCE
TOTAL CAPACITY* ........................ _______ MBH
SENSIBLE CAPACITY* .................. _______ MBH
OUTDOOR DESIGN TEMP. _______ °F [°C] DB/WB
TOTAL SUPPLY AIR ................ _______ CFM [L/s]
TEMP. OF AIR ENTERING
EVAPORATOR COIL...... _______ °F [°C] DB/WB
POWER INPUT REQUIREMENT ...... _______ KW
SEER RATING........................................ _______
(*uses blower motor heat)
HEATING PERFORMANCE
HEAT PUMP HEATING PERFORMANCE
CAPACITY @ 47°F .......................... ________MBH
CAPACITY @ 17°F .......................... ________MBH
COEFFICIENT OF PERFORMANCE
@ 47°F............................................ ________C.O.P.
@ 17°F............................................ ________C.O.P.
ELECTRIC HEAT CAPACITY ............ _______ KW
H.S.P.F. ...................................................... _______
SUPPLY AIR BLOWER PERFORMANCE
TOTAL SUPPLY AIR ................ _______ CFM [L/s]
TOTAL RESISTANCE EXTERNAL
TO UNIT...................................... _______ IWG
BLOWER SPEED .......................... _______ RPM
POWER OUTPUT REQUIREMENT .. _______ BHP
MOTOR RATING ........................ _______ HP [W]
POWER INPUT REQUIREMENT ...... _______ KW
ELECTRICAL DATA
POWER SUPPLY...................... ____________ Hz
TOTAL UNIT AMPACITY................ _______ AMPS
MINIMUM WIRE SIZE .................... _______ AWG
MAXIMUM OVERCURRENT DEVICE
FUSES HACR BREAKER ........ _______ AMPS
TOTAL UNIT WEIGHT
TOTAL OPERATING WEIGHT .... _______ LBS [kg]
(including field-installed accessories)
CLEARANCES
SIDE “A”
(WITHOUT ECONOMIZER)
2" [50.8 mm]
SIDE “B”
(WITHOUT ECONOMIZER)
12" [304.8 mm]
SIDE “C”
(WITHOUT ECONOMIZER)
48" [1,219.2 mm]
SIDE “D”
(WITHOUT ECONOMIZER)
24" [610 mm]
ABOVE UNIT
(WITHOUT ECONOMIZER)
60" [1,524 mm]
OUTDOOR FAN
GRILLE &
COMPRESSOR ACCESS
5013/16
"
[1290 mm]
4719/32
"
[1209 mm]
BOTTOM
RETURN
DUCT
OPENING
BOTTOM
SUPPLY
DUCT
OPENING
451/16
"
[1145 mm]
INSIDE 13/16
"
[30 mm]
TYP.
153/8
"
[391 mm]
11/2
"
[38 mm]
TYP.
497/16
"
[1256 mm]
INSIDE
141/4
"
[362 mm]
TYP. 199/16
"
[497 mm]
313/16
"
[97 mm]
45/16
"
[95 mm]
33/16
"
[97 mm]
BOTTOM VIEW
TOP VIEW
Sloped Curb
JOB NAME DATE
CONTRACTOR UNIT DESIGNATION
ENGINEER MODEL NO.
SUBMITTED FOR APPROVAL RECORD LOCATION
SUBMITTED BY ORDER NO.
Roof Curb (14" [355.6 mm & 24" [609.6 mm]
Sloped Platform) ..............................................
Filter Accessory......................................................
Lift Kit (For Rigging) ..............................................
Time Delay Relay ..................................................
Start Assist ..........................................................
Low Ambient Control ..............................................
Low Pressure Control ............................................
Economizer (Enthalpy Controlled) Downflow Only ....
Manual Fresh Air Damper ......................................
L.P. (Propane) Kit ..................................................
Transition (Rectangular-Round) Downflow/Sideflow ..
Concentric Diffuser and Grille ..................................
High Pressure Control ............................................
Thermostat ..........................................................
FIELD INSTALLED ACCESSORIES
133/4
"
[349 mm]
SIDE SUPPLY
DUCT OPENING
SHOWN WITH DUCT COVERS REMOVED.
LIQUID
PRESSURE
SERVICE PORT
CONTROL
ACCESS PANEL
THREADED PVC
CONDENSATED DRAIN
CONNECTION (3/4 N.P.T.)
SIDE RETURN
DUCT OPENING
SUCTION PRESSURE
SERVICE PORT
471/2
"
[1207 mm]
2211/16
"
[576 mm]
75/16
"
[186 mm]
47/16
"
[113 mm] 15
"
[381 mm]
81/2
"
[216 mm]
TYP.
47/8
"
[124 mm]
143/16
"
[360 mm]
TYP.
191/8
"
[486 mm]
57/16
"
[138 mm]
21/2
"
[63.5 mm]
Model Number Height “A”
B024, B025 3515/16
B030, B036, B042, B048 41
FILTER ACCESS PANEL (FOR UNIT
MOUNTED FILTER ACCESSORY
BLOWER/
EVAPORATOR
ACCESS PANEL
OUTDOOR
COIL PROTECTIVE
GRILLE
THERMOSTAT
WIRE ENTRANCE
ELECTRICAL
POWER ENTRANCE
43/4
"
[121 mm]
51/16
"
[129 mm]
103/16
"
[259 mm]
255/16
"
[643 mm]
11/8
"
[29 mm]
527/16
"
[1332 mm]
SIDE VIEW SIDE VIEW
FRONT VIEW REAR VIEW
Before proceeding with installation, refer
to installation instructions packaged
with each model, as well as complying
with all Federal, State, Provincial, and
Local codes, regulations, and practices. Rheem Sales Company, Inc.
P.O. Box 17010, Fort Smith, AR 72917
“In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice.”
PRINTED IN U.S.A. 8-09 DC FORM NO. X33-1234 REV. 1
Supersedes Form No. X33-1234