Rheem Classic Series Up To 85 9 Afue Ecm And Psc Motors Submittal Sheet

2015-04-02

: Rheem Rheem-Classic-Series-Up-To-85-9-Afue-Ecm-And-Psc-Motors-Submittal-Sheet-683965 rheem-classic-series-up-to-85-9-afue-ecm-and-psc-motors-submittal-sheet-683965 rheem pdf

Open the PDF directly: View PDF PDF.
Page Count: 3

DownloadRheem Rheem-Classic-Series-Up-To-85-9-Afue-Ecm-And-Psc-Motors-Submittal-Sheet-  Rheem-classic-series-up-to-85-9-afue-ecm-and-psc-motors-submittal-sheet
Open PDF In BrowserView PDF
Rely on Ruud.™

SUBMITTAL COVER SHEET
PROJECT NAME
LOCATION
ARCHITECT
ENGINEER
CONTRACTOR
SUBMITTED BY

DATE

UNIT SUMMARY
Quantity
Unit Designation
Model No.
Total Cooling
Sensible Cooling
Air Ent. Evaporator
Air Lvg. Evaporator
Heating Input
Heating Output
CFM/ESP
EER/SEER
Electrical
Minimum Ampacity
Min.-Max. Breaker
Net Unit Weight
Accessory
Catalog Form Number

ACCESSORIES:

NOTES:

Rely on Ruud.™
FORM NO. M22-1640

FORM NO. X33-1357 REV. 1

SUBMITTAL SHEET FOR HIGHBOY & LOWBOY OIL
FURNACES WITH ECM/VARIABLE SPEED MOTORS
ROCA-***E: Highboy Series
ROLA-***E: Lowboy Series
Input Ratio from 84,000 to 175,000 BTU/HR [24.61 to 51.28 kW]
JOB NAME

MODEL NO.

CONTRACTOR

OUTDOOR UNIT MODEL NO.

ENGINEER

LOCATION

SUBMITTED FOR

APPROVAL

RECORD

ORDER NO.

DATE

UNIT DATA

FEATURES FOR ROCA/ROLA

HEATING PERFORMANCE

The Rheem Classic Series ® premium upflow oil furnace is for installation in proper ventilated utility rooms, closets or alcoves.
■ ECM blower assemblies for heating and air conditioning applications
■ ECM Control board located in furnace vestibule
■ ECM controls set for 2-stage air conditioning, 2-stage heat pump
back up
■ 10-gauge primary and 14-gauge secondary heat exchanger
■ Front cleanout ports extend through front wall for accessibility
■ Efficiencies up to 85.9%
■ Front or rear flue Lowboys available
■ All furnaces have standard Honeywell controls
■ Available with Beckett, Riello Carlin burners
■ Extended vestibule on all units

TOTAL CAPACITY INPUT* ...... _______ MBH [kW]
TOTAL CAPACITY OUTPUT* .. _______ MBH [kW]
DESIGN TEMP. RISE .............. _______ °F [°C] DB
AFUE ................................................ _______ %
CALIFORNIA SEASONAL
EFFICIENCY .................................. _______ %
(*uses blower motor heat)

SUPPLY AIR BLOWER PERFORMANCE
TOTAL AIR SUPPLY ................ _______ CFM [L/s]
TOTAL RESISTANCE EXTERNAL
TO UNIT...................................... _______ IWG
BLOWER SPEED .......................... _______ RPM
POWER OUTPUT REQUIREMENT .. _______ BHP
MOTOR RATING ........................ _______ HP [W]
POWER INPUT REQUIREMENT ........ _______ kW

ELECTRICAL DATA
POWER SUPPLY .............................. _______ Hz
TOTAL UNIT AMPACITY................ _______ AMPS
MINIMUM WIRE SIZE .................... _______ AWG
MAXIMUM OVERCURRENT DEVICE
FUSES/HACR BREAKER .......... _______ AMPS

ENER

UIDE

Annual Fuel Utilization Efficiency -

AFUE

THIS MODEL

80.0%

MID
78%

82%

HIGH
88%

97%

DIMENSIONS

Lowboy

Highboy

DIMENSIONS
Lowboy*

Model

ROLA-070E

Cabinet Height (A)
Cabinet Width (B)
Cabinet Depth (C)
Centerline - Flue to Floor (D)
Centerline - Flue to Side (E)
Warm Air Supply Depth (G)
Warm Air Supply Width (Ho)
Return Air Supply Width (Hr)
Return Air Supply Depth (J)
Shipping Weight

40"
20-1/4"
47-1/2"
31-1/4"
10-1/8"
17-1/2"
18-1/4"
18-1/4"
14"
323 lbs.

Highboy
ROLA-115E
DIMENSIONS
46"
25-1/8"
53-5/8"
38-1/2"
12-1/2"
21-1/2"
22-7/8"
22-7/8"
13-5/8"
362 lbs.

ROCA-070E

ROCA-115E

53-5/8"
22-1/4"
33-1/8"
49-1/8"
11-1/8"
19-3/4"
20-1/2"
15"
23-5/8"
298 lbs.

56-1/2"
25-1/2"
38"
52-5/8"
12-3/4"
23-3/8"
23-3/4"
15"
23-5/8"
347 lbs.

* Specify front or rear flue on Lowboy models

[ ] Designates Metric Conversions

Before proceeding with installation, refer
to installation instructions packaged
with each model, as well as complying
with all Federal, State, Provincial, and
Local codes, regulations, and practices.

Rheem Sales Company, Inc.
P.O. Box 17010, Fort Smith, AR 72917

“In keeping with its policy of continuous progress and product improvement, Manufacturer reserves the right to make changes without notice.”
PRINTED IN U.S.A.

2-13 QG

FORM NO. X33-1357 REV. 1
Supersedes Form No. X33-1299



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : No
Create Date                     : 2013:02:05 15:35:07-06:00
Modify Date                     : 2013:03:01 12:33:22-06:00
Has XFA                         : No
XMP Toolkit                     : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26
Producer                        : Acrobat Distiller 10.0.0 (Macintosh)
Metadata Date                   : 2013:03:01 12:33:22-06:00
Format                          : application/pdf
Title                           : untitled
Document ID                     : uuid:4f59fe69-c60e-ae49-8908-239923483469
Instance ID                     : uuid:e4b87d9b-5eee-0e42-b07d-f9668e310914
Page Count                      : 3
EXIF Metadata provided by EXIF.tools

Navigation menu