Rheem Classic Series Up To 85 9 Afue Ecm And Psc Motors Submittal Sheet
2015-04-02
: Rheem Rheem-Classic-Series-Up-To-85-9-Afue-Ecm-And-Psc-Motors-Submittal-Sheet-683965 rheem-classic-series-up-to-85-9-afue-ecm-and-psc-motors-submittal-sheet-683965 rheem pdf
Open the PDF directly: View PDF .
Page Count: 3
SUBMITTAL COVER SHEET
Quantity
Unit Designation
Model No.
Total Cooling
Sensible Cooling
Air Ent. Evaporator
Air Lvg. Evaporator
Heating Input
Heating Output
CFM/ESP
EER/SEER
Electrical
Minimum Ampacity
Min.-Max. Breaker
Net Unit Weight
Accessory
Catalog Form Number
ACCESSORIES: NOTES:
PROJECT NAME
LOCATION
ARCHITECT
ENGINEER
CONTRACTOR
SUBMITTED BY DATE
UNIT SUMMARY
Rely on Ruud. ™
FORM NO. M22-1640
Rely on Ruud.™
FORM NO. X33-1357 REV. 1
JOB NAME MODEL NO.
CONTRACTOR OUTDOOR UNIT MODEL NO.
ENGINEER LOCATION
SUBMITTED FOR APPROVAL RECORD ORDER NO.
DATE
SUBMITTAL SHEET FOR HIGHBOY & LOWBOY OIL
FURNACES WITH ECM/VARIABLE SPEED MOTORS
ROCA-***E: Highboy Series
ROLA-***E: Lowboy Series
Input Ratio from 84,000 to 175,000 BTU/HR [24.61 to 51.28 kW]
UNIT DATA
HEATING PERFORMANCE
TOTAL CAPACITY INPUT* ...... _______ MBH [kW]
TOTAL CAPACITY OUTPUT* .. _______ MBH [kW]
DESIGN TEMP. RISE .............. _______ °F [°C] DB
AFUE ................................................ _______ %
CALIFORNIA SEASONAL
EFFICIENCY .................................. _______ %
(*uses blower motor heat)
SUPPLY AIR BLOWER PERFORMANCE
TOTAL AIR SUPPLY ................ _______ CFM [L/s]
TOTAL RESISTANCE EXTERNAL
TO UNIT...................................... _______ IWG
BLOWER SPEED .......................... _______ RPM
POWER OUTPUT REQUIREMENT .. _______ BHP
MOTOR RATING ........................ _______ HP [W]
POWER INPUT REQUIREMENT........ _______ kW
ELECTRICAL DATA
POWER SUPPLY .............................. _______ Hz
TOTAL UNIT AMPACITY................ _______ AMPS
MINIMUM WIRE SIZE .................... _______ AWG
MAXIMUM OVERCURRENT DEVICE
FUSES/HACR BREAKER .......... _______ AMPS
FEATURES FOR ROCA/ROLA
The Rheem
Classic Series®
premium upflow oil furnace is for installa-
tion in proper ventilated utility rooms, closets or alcoves.
■ECM blower assemblies for heating and air conditioning applications
■ECM Control board located in furnace vestibule
■ECM controls set for 2-stage air conditioning, 2-stage heat pump
back up
■10-gauge primary and 14-gauge secondary heat exchanger
■Front cleanout ports extend through front wall for accessibility
■Efficiencies up to 85.9%
■Front or rear flue Lowboys available
■All furnaces have standard Honeywell controls
■Available with Beckett, Riello Carlin burners
■Extended vestibule on all units
Annual Fuel Utilization Efficiency -
AFUE
THIS MODEL
ENER UIDE
97%78%
HIGH
MID
82% 88%
80.0%
Before proceeding with installation, refer
to installation instructions packaged
with each model, as well as complying
with all Federal, State, Provincial, and
Local codes, regulations, and practices. Rheem Sales Company, Inc.
P.O. Box 17010, Fort Smith, AR 72917
“In keeping with its policy of continuous progress and product improvement, Manufacturer reserves the right to make changes without notice.”
PRINTED IN U.S.A. 2-13 QG FORM NO. X33-1357 REV. 1
Supersedes Form No. X33-1299
Lowboy
Model Lowboy*
ROLA-070E ROLA-115E
DIMENSIONS
Cabinet Width (B) 20-1/4" 25-1/8"
Highboy
ROCA-070E
22-1/4" 25-1/2"
ROCA-115E
Cabinet Depth (C) 47-1/2" 53-5/8" 33-1/8" 38"
Centerline - Flue to Floor (D) 31-1/4" 38-1/2" 49-1/8" 52-5/8"
Centerline - Flue to Side (E) 10-1/8" 12-1/2" 11-1/8" 12-3/4"
Warm Air Supply Depth (G) 17-1/2" 21-1/2" 19-3/4" 23-3/8"
Warm Air Supply Width (Ho) 18-1/4" 22-7/8" 20-1/2" 23-3/4"
Return Air Supply Width (Hr) 18-1/4" 22-7/8" 15" 15"
Return Air Supply Depth (J) 14" 13-5/8" 23-5/8" 23-5/8"
Shipping Weight 323 lbs. 362 lbs. 298 lbs. 347 lbs.
53-5/8"Cabinet Height (A) 40" 46" 56-1/2"
* Specify front or rear flue on Lowboy models
[ ] Designates Metric Conversions
DIMENSIONS
DIMENSIONS
Highboy