Air Gas Furnaces RGRL Series Rheem Classic® Series Two-Stage Upflow Gas Furnaces RGRL- Series 95% A.F.U.E. or Above Input Rates of 45, 60, 75, 90 & 105 kBTU [13.19, 17.58, 22, 26.38 & 30.77 kW] With Dual Comfort Control™ ✝ A.F.U.E. (Annual Fuel Utilization Efficiency) calculated in accordance with Department of Energy test procedures. • The Rheem Classic ® Series 90 Plus with Dual Comfort Control ™ line of upflow gas furnaces are designed for utility rooms, closets, alcoves, or attics. Because of the low-profile 34 inch [864 mm] height, the upflow model can also be used to satisfy most applications. The design is certified by CSA. • Two stages of operation to save energy and maintain optimal comfort level. • Furnace operates at 70% capacity for low-heat and 100% capacity for high-heat. • Compatible with single or two-stage thermostat. (For optimal performance a two-stage thermostat is recommended.) • Heat exchanger is constructed of aluminized steel for maximum corrosion resistance and thermal fatigue reliability. • Low profile “34 inch” design is lighter and easier to handle and leaves room for optional accessories. • Left or right side gas, electric, and condensate drainage connections. • Integrated control board manages all operational functions and provides hookups for humidifier and electronic air cleaner. • An insulated blower compartment, a slow-opening gas valve and a specially designed inducer system make it one of the quietest furnaces on the market today. • Features a Limited Lifetime Warranty on the primary and secondary heat exchanger and a 10-Year Limited Warranty on all other parts. • Molded permanent filters. • Optional indoor or outdoor combustion air. In addition, combustion air may be piped to either the top or side of the cabinet on all upflow models. A special molded fitting is provided to ease installation. • Dual certified for sealed combustion (2-pipe) or non-direct (1-pipe) applications. • Solid bottom is standard. • Control board diagnostics. • A variety of cooling coils and plenums designed to use with the Rheem Classic ® Series 90 Plus gas furnaces are available as optional accessories for air conditioning models. FORM NO. G11-525 Air Table of Contents RGRL Series TABLE OF CONTENTS Standard & Optional Equipment ......................................................................3 Physical Data & Specifications ........................................................................4 Model Number Identification ............................................................................5 Dimensional Data............................................................................................6 Blower Performance Data ................................................................................7 Accessories....................................................................................................8 Limited Warranty ............................................................................................9 2 Air Standard & Optional Equipment RGRL Series REMOTE SENSOR DIRECT SPARK IGNITION & REMOTE SENSOR PRIMARY AND SECONDARY HEAT EXCHANGER IN-SHOT BURNERS GAS VALVE AND MANIFOLD PRESSURE SWITCHES DRAFT INDUCER INTEGRATED FURNACE CONTROL STANDARD EQUIPMENT OPTIONAL EQUIPMENT Completely assembled and wired; heat exchanger; primary: aluminized steel, secondary: 29-4C stainless steel; induced draft; pressure switches; redundant main gas control; blower compartment door safety switch; solid state time on/off blower control; limit controls; manual shut-off valve; 100% safety lock out; cool fan off delay; field selectable heat fan off delay; one hour automatic retry; power and self-test diagnostics; flame sense current diagnostics; electronic air cleaner connections; twinning (built-in) features; humidifier connections; humidifier on/off delay; low speed continuous fan option; single speed option for heating and cooling applications; pressure regulator for natural and L.P. (propane) gasses; transformer; direct drive, multi-speed blower motor. (Please note: a thermostat is not included as standard equipment.) Side and bottom filter racks; return air cabinet for all sizes. NOTE: Furnace is not listed for use with fuels other than natural or L.P. (propane) gas. All models can be converted by a qualified distributor or local service dealer to use L.P. (propane) gas without changing burners. Factory approved kits must be used to convert from natural to L.P. (propane) gas and may be ordered as optional accessories from a parts distributor. For L.P. (propane) operation, refer to Conversion Kit Index Form. WARNING THIS FURNACE IS NOT APPROVED OR RECOMMENDED FOR USE IN MOBILE HOMES 3 Air Physical Data & Specifications RGRL Series Physical Data and Specifications—Upflow Models U.S. and Canadian Models MODEL NUMBERS HIRE FIRE INPUT BTU/HR [kW] ➀ RGRL-04*MAES 45,000 [13.19] RGRL-06*MAES 60,000 [17.58] RGRL-07*MAES 75,000 [21.98] RGRL-07*YBGS 75,000 [21.98] RGRL-09*ZAJS 90,000 [26.38] RGRL-10*ZAJS 105,000 [30.77] 31,500 [9.23] 42,000 [12.31] 30,600 [8.97] 42,000 [12.31] 56,000 [16.41] 40,800 [11.96] 52,500 [15.39] 70,000 [20.51] 51,000 [14.95] 52,500 [15.39] 70,000 [20.51] 51,000 [14.95] 63,000 [18.46] 84,000 [24.62] 61,200 [17.94] 73,500 [21.54] 100,000 [29.27] 71,400 [20.93] 28,458 [8.34] 37,944 [11.12] 47,430 [13.90] 47,430 [13.90] 56,916 [16.69] 66,402 [19.46] 11 x 7 [279 x 178] 11 x 7 [279 x 178] 11 x 7 [279 x 178] 12 x 7 [305 x 178] 12 x 11 [305 x 279] 12 x 11 [305 x 279] LOW FIRE INPUT BTU/HR [kW] ➁ HEATING CAPACITY BTU/HR [kW] HIGH ALTITUDE INPUT 8000' ➁ HIGH ALTITUDE OUTPUT AT 8000' (HIGH FIRE) [kW] ➁ BLOWER (D x W) [mm] MOTOR H.P. [W]– SPEEDS–TYPE MOTOR FULL LOAD AMPS HEATING SPEED-HIGH FIRE HEATING SPEED-LOW FIRE COOLING SPEED HEAT EXT. STATIC PRESSURE (IN. W.C.) [kPa] RATED EXT. STATIC PRESSURE (IN. W.C.) [kPa] 1/2 [373]-4-PSC 1/2 [373]-4-PSC 1/2 [373]-4-PSC 3/4 [559]-4-PSC 3/4 [559]-4-PSC 3/4 [559]-4-PSC 6.8 6.8 6.8 9.5 9.5 9.5 MED-LO LOW HIGH MED-LO LOW HIGH MED-HI MED-LOW HIGH MED-HI LOW HIGH MED-HI MED-LO HIGH MED-HI MED-LO HIGH .10 [.025] .12 [.029] .12 [.029] .12 [.029] .15 [.037] .20 [.049] .50 [.124] .50 [.124] .50 [.124] .50 [.124] .50 [.124] .50 [.124] 885 [417] 845 [398] 1050 [495] 1275 [600] 1465 [691] 1445 [682] HEATING CFM @ .2" [.049 kPa] W.C. E.S.P. [L/s] COOLING CFM @ .5" [.124 kPa] W.C. E.S.P. [L/s] TEMPERATURE RISE-HIGH FIRE RANGE °F [°C] 1195 [564] 1100 [519] 1100 [519] 1540 [725] 1910 [901] 1810 [854] 30-60 [16.7-33.3] 40-70 [22.2-38.9] 40-70 [22.2-38.9] 35-65 [19.4-36.1] 35-65 [19.4-36.1] 50-80 [27.8-44.4] TEMPERATURE RISE-LOW FIRE RANGE °F [°C] 15-45 [8.3-25] 30-60 [16.7-33.3] 40-70 [22.2-38.9] 25-55 [13.9-30.6] 25-55 [13.9-30.6] 35-65 [19.4-36.1] RETURN AIR CABINETS (OPT.) RXGRFILTER SIZE [mm] C17B (2) 12" x 16" [305 x 406] C17B (2) 12" x 16" [305 x 406] C21B (2) 12" x 20" [305 x 508] C21B (2) 12" x 20" [305 x 508] C21B (2) 20" x 16" [508 x 406] C21B (2) 20" x 16" [508 x 406] 153/4 x 25 x 1 153/4 x 25 x 1 153/4 x 25 x 1 153/4 x 25 x 1 191/4 x 25 x 1 191/4 x 25 x 1 111 [50.3] 117 [53.1] 123 [55.8] 145 [65.5] 148 [67.1] 152 [68.9] 95% 95.0% 95.0% STANDARD, HIGH VELOCITY PERMANENT FILTER (IN.) APPROX. SHIPPING WEIGHT (LBS.) [kg] 95.0% 95.0% 95% AFUE ➂ NOTES: All models are 115V, 60HZ, 1ø. Gas connection size for all models is 1/2" [13 mm] N.P.T. ➀ See Conversion Kit Index Form for high altitude derate. ➁ Canadian installations only. ➂ In accordance with D.O.E. test procedures. *E = Standard *N = NOx Models [ ] Designates Metric Conversions 4 Air Model Number Identification RGRL Series Model Number Identification R Rheem G R L — Gas Upflow/ Design Furnace Condensing Series Gas Furnace 07E* Heating Input Designation Electric Ignition 04* 06* 07* 09* Blower Size M = 11 x 7 [279 x 178 mm] R = 11 x 10 Input [279 x 254 mm] BTU/HR Z = 12 x 11 45,000 [13 kW] [305 x 279 mm] 60,000 [17.6 kW] Y = 12 x 7 75,000 [22 kW] [305 x 178 mm] 90,000 [26.4 kW] NOTES: *E = Standard *N = NOx Models [ ] Designates Metric Conversions Y B G Variations Heat/Cool A = Std. Designation B = Wide E = 1100-1300 CFM Cabinet [519-613.5 L/s] G = 1500-1700 CFM [707.9-802.3 L/s] J = 1900-2100 CFM [896.7-991.1 L/s] S 278 Fuel Code S = U.S. and Canadian Natural Gas Option Code for High Altitude Available Models: RGRL-04EMAES RGRL-07EYBGS RGRL-04NMAES RGRL-07NYBGS RGRL-04EMAES278 RGRL-09EZAJS RGRL-06EMAES RGRL-09NZAJS RGRL-06NMAES RGRL-09EZAJS278 RGRL-06EMAES278 RGRL-10EZAJS RGRL-07EMAES RGRL-10NZAJS RGRL-07NMAES 5 Air Dimensional Data RGRL Series MODEL RGRL- A B C D E F LEFT SIDE 04*M 06*M 07*M 07*Y 09*Z 10*Z 171/2 [445] 171/2 [445] 171/2 [445] 21 [533] 21 [533] 21 [533] 1611/32 [415] 1611/32 [415] 1611/32 [415] 1927/32 [504] 1927/32 [504] 1927/32 [504] 155/8 [397] 155/8 [397] 155/8 [397] 191/8 [487] 191/8 [487] 191/8 [487] 2 [51] 2 [51] 2 [51] 2 [51] 2 [51] 2 [51] 15 [422] 15 [422] 15 [422] 181/2 [511] 181/2 [511] 181/2 [511] 1325/32 [352] 1325/32 [352] 1325/32 [352] 179/32 [441] 179/32 [441] 179/32 [441] 0 0 0 0 0 0 *E=Standard *N=NOx Models [ ] Designates Metric Conversions 6 MINIMUM CLEARANCE (IN.) [mm] RIGHT BACK TOP FRONT VENT SIDE 0 0 1 [25] 2 [51] 0 0 0 1 [25] 2 [51] 0 0 0 1 [25] 2 [51] 0 0 0 1 [25] 2 [51] 0 0 0 1 [25] 2 [51] 0 0 0 1 [25] 2 [51] 0 SHIP WGTS. [kg] 111 [50] 117 [53] 123 [56] 145 [66] 148 [67] 152 [69] Air MODEL RGRL- BLOWER SIZE [mm] MOTOR H.P. [W] 04*M 11 x 7 [279 x 178] 1/2 [373] 06*M 11 x 7 [279 x 178] 1/2 [373] 07*Y 12 x 7 [305 x 178] 3/4 [559] 07*M 11 x 7 [279 x 178] 1/2 [373] 09*Z *** 12 x 11 [305 x 279] 3/4 [559] 10*Z *** 12 x 11 [305 x 279] 3/4 [559] BLOWER SPEED LOW MED-LO MED-HI HIGH LOW MED-LO MED-HI HIGH LOW MED-LO MED-HI HIGH LOW MED-LO MED-HI HIGH LOW MED-LO MED-HI HIGH LOW MED-LO MED-HI HIGH 0.1 [.02] 805 [380] 920 [434] 1140 [538] 1360 [642] 770 [363] 880 [415] 1060 [500] 1260 [594] 1105 [522] 1290 [609] 1480 [698] 1705 [805] 780 [368] 880 [415] 1090 [514] 1300 [613] 1235 [582] 1490 [703] 1720 [811] 2100 [991] 1230 [680] 1490 [703] 1710 [807] 2010 [949] Blower Performance Data RGRL Series CFM [L/s] AIR DELIVERY EXTERNAL STATIC PRESSURE INCHES WATER COLUMN [kPa] 0.2 [.05] 0.3 [.07] 0.4 [.10] 0.5 [.12] 0.6 [.15] 780 [368] 760 [358] 720 [340] 685 [323] 645 [304] 885 [417] 850 [401] 810 [382] 775 [365] 730 [344] 1110 [524] 1085 [512] 1045 [493] 1010 [476] 950 [448] 1320 [623] 1280 [604] 1235 [583] 1195 [564] 1140 [538] 740 [349] 710 [335] 675 [318] 645 [304] 605 [285] 845 [398] 815 [384] 790 [373] 760 [358] 715 [337] 1025 [483] 990 [467] 960 [453] 925 [436] 880 [415] 1215 [573] 1175 [554] 1135 [535] 1100 [519] 1040 [491] 1096 [517] 1080 [610} 1050 [498] 1030 [466] 1010 [477] 1275 [602] 1280 [605] 1220 [678] 1195 [564] 1170 [552] 1435 [677] 1415 [668] 1390 [658] 1370 [647] 1300 [614] 1665 [788] 1615 [762] 1570 [741] 1540 [727] 1475 [696] 745 [351] 710 [335] 675 [318] 640 [302] 595 [281] 850 [401] 825 [389] 785 [370] 750 [354] 702 [331] 1050 [495] 1010 [477] 970 [458] 925 [436] 875 [413] 1255 [592] 1210 [571] 1160 [547] 1110 [524] 1055 [498] 1210 [571] 1185 [559] 1150 [543] 1120 [528] 1075 [507] 1465 [691] 1440 [679] 1405 [663] 1375 [649] 1315 [620] 1670 [788] 1620 [764] 1600 [755] 1580 [746] 1520 [717] 2050 [967] 2000 [944] 1955 [923] 1910 [901] 1825 [861] 1205 [567] 1160 [557] 1155 [545] 1130 [583] 1090 [514] 1445 [682] 1405 [663] 1375 [649] 1350 [637] 1295 [611] 1665 [786] 1620 [764] 1570 [746] 1540 [727] 1475 [696] 1955 [923] 1900 [897] 1655 [875] 1810 [854] 1710 [607] 0.7 [.17] 605 [285] 690 [325] 890 [420] 1080 [500] 570 [269] 670 [316] 835 [394] 985 [465] 990 [467] 1140 [538] 1255 [592] 1400 [661] 555 [261] 655 [309] 825 [389] 1005 [474] 1035 [488] 1255 [592] 1460 [689] 1745 [823] 1050 [495] 1240 [585] 1410 [665] 1610 [769] ***E=Standard ***N=NOx Models ***Where the maximum airflow is above 1800 CFM or more, both sides or 1 side and the bottom must be used for return air to maximize airflow. NOTE: CFM values represent furnace-only airflow ratings. [ ] Designates Metric Conversions 7 Accessories RGRL Series Air VENT TERMINATION KITS CONCENTRIC: HORIZONTAL/VERTICAL = RXGY-E03A (US & Canadian Installations) HORIZONTAL TWO PIPE: RXGY-D02, RXGY-D03, RXGY-D04 (US Installations) RXGY-D02A, RXGY-D03A, RXGY-D04A (Canadian Installations) RXGY-G02 (US Only) CONDENSATE PUMP KIT: RXGY-B01 NEUTRALIZER KIT: RXGY-A01 FOSSIL FUEL KIT: RXPF-F01, RXPF-F02 (TVA) RETURN AIR PLENUM: RXGR-C17B, RXGR-C21B, RXGR-C24B LP CONVERSION KITS: U.S./Canadian RXGJ-FP26 or RXGJ-FP21 EXTERNAL BOTTOM FILTER RACK: RXGF-CB EXTERNAL SIDE FILTER RACK: RXGF-CA MODEL RGRL- FILTER RACK FILTER SIZES* INCHES [mm] RXGF-CB RXGF-CA (BOTTOM) (SIDE) 04 153/4 x 25 [400 x 635] 153/4 x 25 [400 x 635] 06 153/4 x 25 [400 x 635] 153/4 x 25 [400 x 635] 07EM 07NM 153/4 x 25 [400 x 635] 153/4 x 25 [400 x 635] 07EY 07NY 191/4 x 25 [489 x 635] 153/4 x 25 [400 x 635] 191/4 x 25 [489 x 635] 191/4 x 25 [489 x 635] 153/4 x 25 [400 x 635] 153/4 x 25 [400 x 635] 09 10 *Filter racks are shipped without filters. Filters shipped with furnace may be used or a suitable 1" [25.4 mm] filter. [ ] Designates Metric Conversions 8 FOR HIGH ALTITUDES: HIGH ALTITUDE KIT: INPUT BTU/HR [kW] 45,000 [13] HIGH ALTITUDE KIT NO. RXGY-F18 60,000 [18] RXGY-F18 75,000 [22] Not Required 90,000 [26] 105,000 [31] RXGY-F20 Not Required NOTE: High altitude kits and options do NOT include additional burner orifices. If a burner orifice change is necessary, they must be ordered through PROSTOCK®. See Installation Instructions for more information. Option – 278 furnaces are shipped with #51 DMS orifices installed. This is one drill size smaller than standard furnaces to account for expected average elevations and heating values typically seen in these areas. CAUTION: Always follow National Fuel Gas Code (NFGC) guidelines when converting for high altitudes. For all installations above 2000 ft. (including all option – 278 models), the burner orifice size needs to be recalculated and verified. A burner orifice change may still be required. See Installation Instructions for more information. NOTE: For Canadian installations only, an optional derate (manifold gas pressure reduction) method may be used to adjust the furnace for altitude. See Installation Instructions for more information. This optional method may NOT be used for U.S. installations. (U.S. Models—Kit packaged with furnace. Requires field installation). Air Limited Warranty RGRL Series GENERAL TERMS OF LIMITED WARRANTY* Rheem will furnish a replacement for any part of this product which fails in normal use and service within the applicable period stated, in accordance with the terms of the limited warranty. Conditional Parts (Registration Required) ...............................Ten (10) Years Heat Exchanger .........................................Limited Lifetime *For complete details of the Limited and Conditional Warranties, including applicable terms and conditions, contact your local contractor or the Manufacturer for a copy of the product warranty certificate. 9 Air 10 Notes RGRL Series Air Notes RGRL Series 11 The new degree of comfort.™ In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice. Rheem Heating, Cooling & Water Heating • P.O. Box 17010 Fort Smith, Arkansas 72917 • www.rheem.com Rheem Canada Ltd./Ltée • 125 Edgeware Road, Unit 1 Brampton, Ontario • L6Y 0P5 PRINTED IN U.S.A 05/12 QG FORM NO. G11-525
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : No XMP Toolkit : 3.1-701 Producer : Acrobat Distiller 9.5.0 (Macintosh) Create Date : 2012:05:02 12:07:12-05:00 Modify Date : 2012:05:11 12:44:15-05:00 Title : untitled Has XFA : No Page Count : 12EXIF Metadata provided by EXIF.tools