Rheem Classic Series Up To 95 Afue 2 Stage Psc Motor Submittal Sheet
2015-04-02
: Rheem Rheem-Classic-Series-Up-To-95-Afue-2-Stage-Psc-Motor-Submittal-Sheet-683824 rheem-classic-series-up-to-95-afue-2-stage-psc-motor-submittal-sheet-683824 rheem pdf
Open the PDF directly: View PDF .
Page Count: 3
Download | |
Open PDF In Browser | View PDF |
SUBMITTAL COVER SHEET PROJECT NAME ______________________________________________________________________________ LOCATION __________________________________________________________________________________ ARCHITECT__________________________________________________________________________________ ENGINEER __________________________________________________________________________________ CONTRACTOR ______________________________________________________________________________ SUBMITTED BY ______________________________ DATE ________________________________________ UNIT SUMMARY Quantity Unit Designation Model No. Total Cooling Sensible Cooling Air Ent. Evaporator Air Lvg. Evaporator Heating Input Heating Output CFM/ESP EER/SEER Electrical Minimum Ampacity Min.-Max. Breaker Net Unit Weight Accessory Catalog Form Number ACCESSORIES: PRINTED IN U.S.A. NOTES: 10-06 DC FORM NO. X11-1123 REV. 2 Supersedes Form No. X11-1123 Rev. 1 FORM NO. X33-1208 REV. 2 Supersedes X33-1208 Rev. 1 SUBMITTAL SHEET FOR RGTK92% A.F.U.E. OR ABOVE TWO-STAGE DOWNFLOW/HORIZONTAL GAS FURNACES Models with Input Rates from 60,000 to 120,000 BTU/HR [17.58 to 35.17 kW] JOB NAME MODEL NO. CONTRACTOR OUTDOOR UNIT MODEL NO. ENGINEER LOCATION SUBMITTED FOR APPROVAL RECORD ORDER NO. DATE UNIT DATA HEATING PERFORMANCE TOTAL CAPACITY INPUT* ...... _______ MBH [kW] TOTAL CAPACITY OUTPUT* .. _______ MBH [kW] DESIGN TEMP. RISE .............. _______ °F [°C] DB AFUE ................................................ _______ % CALIFORNIA SEASONAL EFFICIENCY .................................. _______ % FEATURES FOR RGTK ■ ■ ■ ■ (*uses blower motor heat) ■ SUPPLY AIR BLOWER PERFORMANCE ■ TOTAL AIR SUPPLY ................ _______ CFM [L/s] TOTAL RESISTANCE EXTERNAL TO UNIT...................................... _______ IWG ■ ■ BLOWER SPEED .......................... _______ RPM POWER OUTPUT REQUIREMENT .. _______ BHP MOTOR RATING ........................ _______ HP [W] POWER INPUT REQUIREMENT ........ _______ kW ELECTRICAL DATA ■ ■ ■ ■ ■ POWER SUPPLY...................... ____________ Hz TOTAL UNIT AMPACITY................ _______ AMPS MINIMUM WIRE SIZE .................... _______ AWG MAXIMUM OVERCURRENT DEVICE FUSES/HACR BREAKER .......... _______ AMPS ■ Two stages of operation to save energy and maintain optimal comfort level. Furnace operates at 70% capacity for low-heat and 100% capacity for high-heat. Compatible with single or two-stage thermostat. (For optimal performance two-stage thermostat recommended.) Heat exchanger tubular construction is stainless steel for maximum corrosion resistance and thermal fatigue reliability. Low profile “34 inch” design is lighter and easier to handle and leaves room for optional accessories. Top electrical connections, left or right side gas, electric, and condensate drainage connections on downflow/horizontal models. Integrated control board manages all operational functions and provides hookups for humidifier and electronic air cleaner. An insulated blower compartment, a slow-opening gas valve and a specially designed inducer system make it one of the quietest furnaces on the market today. Pre-paint galvanized steel cabinet. Molded permanent filters. Optional indoor or outdoor combustion air. Transformer and control fuse protection. Condensate drain trap for horizontal/downflow application provided standard. Control board diagnostics. FIELD INSTALLED ACCESSORIES Plenum Adapter (RXAA-) .................................................................... Vent Termination Kits Concentric: Vertical/Horizontal: RXGY-E03 .................................................... Horizontal Two Pipe: RXGY-D02, RXGY-D03, RXGY-D04, RXGY-G02............................................................ Condensate Pump Kit: RXGY-B01 ...................................................... Neutralizer Kit: RXGY-A01............................................................ Fossil Fuel Kit: RXPF-F01 and F02 .................................................... Return Air Plenum (RXGR-C17B, 21B, 24B) ...................................... External Bottom Filter Rack: RXGF-CB .............................................. External Side Filter Rack: RXGF-CC .................................................. Drain Kit for Converting to Left Drain: RXGY-H01 .............................. High Altitude Kit is not available at this time. DOWNFLOW MODELS A 19/32 [15 mm] 19/32 [15 mm] B RETURN AIR 281/16 [713 mm] 201/8 [511 mm] 3/4 [19 mm] D 19/32 [15 mm] 3/4 [19 mm] 2527/32 [537 mm] 34 [664 mm] 269/16 [678 mm] 2311/16 [602 mm] 241/16 [611 mm] 15/8 [41 mm] ALT. GAS CONNECTION 15/8 [41 mm] DIA. GAS CONNECTION 15/8 [41 mm] DIA. ALT. CONDENSATE DRAIN 413/16 [106 mm] 6 27/64 [163 mm] 15/8 [41 mm] DIA. CONDENSATE DRAIN 413/16 43/32 [106 mm] [104 mm] FRONT LEFT SIDE RIGHT SIDE NOTE: In downflow configuration, return air cut-out is not permitted. HORIZONTAL MODELS 15/8 [41 mm] DIA. 269/16 ALT. CONDENSATE [675 mm] DRAIN 241/16 [611 mm] 15/8 [41 mm] DIA. GAS CONNECTION 413/16 [122 mm] 61/64 [153 mm] 197/8 [505 mm] TOP ELECT. CONN. 113/16 [46 mm] 19/32 [15 mm] SUPPLY AIR E B C F A 2331/32 [609 mm] 223/32 [561 mm] COMBUSTIBLE AIR INLET LOW VOLTAGE VENT OUTLET RETURN AIR LEFT SIDE 37/16 [87 mm] 3/4 [19 mm] FRONT [15 mm] 34 [864 mm] 413/16 [122 mm] 43/32 [104 mm] RIGHT SIDE 19/32 3/4 [19 mm] D 15/8 [41 mm] DIA. ALT. GAS CONNECTION 281/16 [713 mm] 2527/32 [637 mm] 15/8 [41 mm] DIA. CONDENSATE 2311/16 DRAIN [602 mm] 201/16 [511 mm] BOTTOM NOTE: In downflow configuration, return air cut-out is not permitted. 19/32 [15 mm] MODEL RGTK- A B C D E F LEFT SIDE 06 07EM 07EY 09 10 12 171/2 [445] 171/2 [445] 21 [533] 21 [533] 21 [533] 241/2 [622] 1611/32 [415] 1611/32 [415] 1927/32 [504] 1927/32 [504] 1927/32 [504] 2311/32 [593] 155/8 [397] 155/8 [397] 193/16 [486] 193/16 [486] 193/16 [486] 225/8 [575] 2 [51] 2 [51] 2 [51] 2 [51] 2 [51] 2 [51] 165/8 [422] 165/8 [422] 201/8 [511] 201/8 [511] 201/8 [511] 235/8 [600] 137/8 [352] 137/8 [352] 173/8 [441] 173/8 [441] 173/8 [441] 207/8 [530] 0 0 0 0 0 0 MINIMUM CLEARANCE (IN.) [mm] RIGHT BACK TOP FRONT VENT SIDE 0 0 1 [25] 2 [51] 0 0 0 1 [25] 2 [51] 0 0 0 1 [25] 2 [51] 0 0 0 1 [25] 2 [51] 0 0 0 1 [25] 2 [51] 0 0 0 1 [25] 2 [51] 0 SHIP WGTS. [kg] 117 [53] 123 [56] 123 [56] 148 [67] 152 [69] 160 [73] IMPORTANT NOTE: Horizontal furnace may be installed for horizontal left hand air supply ONLY. The condensate trap provided for horizontal application must be installed in the field beneath the unit as directed in the furnace Installation & Operating Instructions. [ ] Designates Metric Conversions Before proceeding with installation, refer to installation instructions packaged with each model, as well as complying with all Federal, State, Provincial, and Local codes, regulations, and practices. Rheem Sales Company, Inc. P.O. Box 17010, Fort Smith, AR 72917 “In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice.” PRINTED IN U.S.A. 10-09 DC FORM NO. X33-1208 REV. 2 Supersedes Form No. X33-1208 Rev. 1
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : No Page Count : 3 Has XFA : No XMP Toolkit : XMP toolkit 2.9.1-13, framework 1.6 About : uuid:870f5640-bf53-11de-8161-003065c4b500 Producer : Acrobat Distiller 4.0 for Macintosh Modify Date : 2009:10:22 16:40:33-05:00 Create Date : 2009:10:22 16:28:43Z Metadata Date : 2009:10:22 16:40:33-05:00 Document ID : uuid:5f4f528a-bf52-11de-8161-003065c4b500 Format : application/pdfEXIF Metadata provided by EXIF.tools