Rheem Classic Series Up To 95 Afue 2 Stage Psc Motor Submittal Sheet
2015-04-02
: Rheem Rheem-Classic-Series-Up-To-95-Afue-2-Stage-Psc-Motor-Submittal-Sheet-683824 rheem-classic-series-up-to-95-afue-2-stage-psc-motor-submittal-sheet-683824 rheem pdf
Open the PDF directly: View PDF .
Page Count: 3
PROJECT NAME ______________________________________________________________________________
LOCATION __________________________________________________________________________________
ARCHITECT__________________________________________________________________________________
ENGINEER __________________________________________________________________________________
CONTRACTOR ______________________________________________________________________________
SUBMITTED BY ______________________________ DATE ________________________________________
UNIT SUMMARY
SUBMITTAL COVER SHEET
Quantity
Unit Designation
Model No.
Total Cooling
Sensible Cooling
Air Ent. Evaporator
Air Lvg. Evaporator
Heating Input
Heating Output
CFM/ESP
EER/SEER
Electrical
Minimum Ampacity
Min.-Max. Breaker
Net Unit Weight
Accessory
Catalog Form Number
ACCESSORIES: NOTES:
PRINTED IN U.S.A. 10-06 DC FORM NO. X11-1123 REV. 2
Supersedes Form No. X11-1123 Rev. 1
FORM NO. X33-1208 REV. 2
Supersedes X33-1208 Rev. 1
JOB NAME MODEL NO.
CONTRACTOR OUTDOOR UNIT MODEL NO.
ENGINEER LOCATION
SUBMITTED FOR APPROVAL RECORD ORDER NO.
DATE
SUBMITTAL SHEET FOR RGTK-
92% A.F.U.E. OR ABOVE TWO-STAGE
DOWNFLOW/HORIZONTAL GAS FURNACES
Models with Input Rates from 60,000 to 120,000 BTU/HR
[17.58 to 35.17 kW]
UNIT DATA
HEATING PERFORMANCE
TOTAL CAPACITY INPUT* ...... _______ MBH [kW]
TOTAL CAPACITY OUTPUT* .. _______ MBH [kW]
DESIGN TEMP. RISE .............. _______ °F [°C] DB
AFUE ................................................ _______ %
CALIFORNIA SEASONAL
EFFICIENCY .................................. _______ %
(*uses blower motor heat)
SUPPLY AIR BLOWER PERFORMANCE
TOTAL AIR SUPPLY ................ _______ CFM [L/s]
TOTAL RESISTANCE EXTERNAL
TO UNIT...................................... _______ IWG
BLOWER SPEED .......................... _______ RPM
POWER OUTPUT REQUIREMENT .. _______ BHP
MOTOR RATING ........................ _______ HP [W]
POWER INPUT REQUIREMENT ........ _______ kW
ELECTRICAL DATA
POWER SUPPLY...................... ____________ Hz
TOTAL UNIT AMPACITY................ _______ AMPS
MINIMUM WIRE SIZE .................... _______ AWG
MAXIMUM OVERCURRENT DEVICE
FUSES/HACR BREAKER .......... _______ AMPS
FEATURES FOR RGTK
■Two stages of operation to save energy and maintain optimal
comfort level.
■Furnace operates at 70% capacity for low-heat and 100% capacity
for high-heat.
■Compatible with single or two-stage thermostat. (For optimal perfor-
mance two-stage thermostat recommended.)
■Heat exchanger tubular construction is stainless steel for maximum
corrosion resistance and thermal fatigue reliability.
■Low profile “34 inch” design is lighter and easier to handle and
leaves room for optional accessories.
■Top electrical connections, left or right side gas, electric, and
condensate drainage connections on downflow/horizontal models.
■Integrated control board manages all operational functions and
provides hookups for humidifier and electronic air cleaner.
■An insulated blower compartment, a slow-opening gas valve and a
specially designed inducer system make it one of the quietest
furnaces on the market today.
■Pre-paint galvanized steel cabinet.
■Molded permanent filters.
■Optional indoor or outdoor combustion air.
■Transformer and control fuse protection.
■Condensate drain trap for horizontal/downflow application provided
standard.
■Control board diagnostics.
FIELD INSTALLED ACCESSORIES
Plenum Adapter (RXAA-) ....................................................................
Vent Termination Kits Concentric:
Vertical/Horizontal: RXGY-E03 ....................................................
Horizontal Two Pipe: RXGY-D02, RXGY-D03,
RXGY-D04, RXGY-G02............................................................
Condensate Pump Kit: RXGY-B01 ......................................................
Neutralizer Kit: RXGY-A01............................................................
Fossil Fuel Kit: RXPF-F01 and F02 ....................................................
Return Air Plenum (RXGR-C17B, 21B, 24B) ......................................
External Bottom Filter Rack: RXGF-CB ..............................................
External Side Filter Rack: RXGF-CC ..................................................
Drain Kit for Converting to Left Drain: RXGY-H01 ..............................
High Altitude Kit is not available at this time.
269/16
[675 mm]
197/8
[505 mm]
SUPPLY
AIR E
LEFT SIDE FRONT RIGHT SIDE
RETURN AIR
COMBUSTIBLE
AIR INLET
LOW VOLTAGE
VENT
OUTLET
CF
BA
D
15/8 [41 mm] DIA.
ALT. CONDENSATE
DRAIN
15/8 [41 mm]
DIA. GAS
CONNECTION
241/16
[611 mm]
413/16
[122 mm]
61/64
[153 mm]
TOP
19/32
[15 mm]
ELECT.
CONN.
113/16
[46 mm]
2331/32
[609 mm]
223/32
[561 mm]
19/32
[15 mm]
3/4
[19 mm]
37/16 [87 mm]
413/16
[122 mm]
43/32
[104 mm]
15/8 [41 mm]
DIA.
CONDENSATE
DRAIN
15/8 [41 mm]
DIA. ALT.
GAS
CONNECTION
2311/16
[602 mm]
2527/32
[637 mm] 201/16
[511 mm]
281/16
[713 mm]
19/32
[
15 mm
]
3/4
[19 mm]
BOTTOM
34
[864 mm]
HORIZONTAL MODELS
[ ] Designates Metric Conversions
MODEL
RGTK- A B C D E F LEFT
SIDE
MINIMUM CLEARANCE (IN.) [mm] SHIP
WGTS.
[kg]
RIGHT
SIDE BACK TOP FRONT VENT
06 171/2[445] 1611/32 [415] 155/8[397] 2 [51] 165/8[422] 137/8[352] 0 0 0 1 [25] 2 [51] 0117 [53]
07EM 171/2[445] 1611/32 [415] 155/8[397] 2 [51] 165/8[422] 137/8[352] 0 0 0 1 [25] 2 [51] 0123 [56]
07EY 21 [533] 1927/32 [504] 193/16 [486] 2 [51] 201/8[511] 173/8[441] 0 0 0 1 [25] 2 [51] 0123 [56]
09 21 [533] 1927/32 [504] 193/16 [486] 2 [51] 201/8[511] 173/8[441] 0 0 0 1 [25] 2 [51] 0148 [67]
10 21 [533] 1927/32 [504] 193/16 [486] 2 [51] 201/8[511] 173/8[441] 0 0 0 1 [25] 2 [51] 0152 [69]
12 241/2[622] 2311/32 [593] 225/8 [575] 2 [51] 235/8 [600] 207/8[530] 0 0 0 1 [25] 2 [51] 0160 [73]
NOTE: In downflow configuration,
return air cut-out is
not permitted.
IMPORTANT NOTE: Horizontal furnace may be installed for horizontal left hand air supply ONLY. The condensate trap provided for horizontal application must
be installed in the field beneath the unit as directed in the furnace Installation & Operating Instructions.
DOWNFLOW MODELS
269/16 [678 mm]
241/16 [611 mm]
15/8 [41 mm] DIA.
GAS CONNECTION
15/8 [41 mm] DIA.
ALT. CONDENSATE
DRAIN
413/16
[106 mm]
6 27/64
[163 mm]
19/32
[15 mm]
19/32
[15 mm]
3/4
[19 mm]
3/4
[19 mm]
281/16
[713 mm]
201/8
[511 mm]
19/32
[15 mm]
34
[664 mm]
413/16
[106 mm] 43/32
[104 mm]
2527/32 [537 mm]
2311/16 [602 mm]
15/8 [41 mm]
ALT. GAS CONNECTION
15/8 [41 mm] DIA.
CONDENSATE DRAIN
D
A
B
RETURN AIR
LEFT SIDE FRONT RIGHT SIDE
NOTE: In downflow configuration, return air cut-out is not permitted.
Before proceeding with installation, refer
to installation instructions packaged
with each model, as well as complying
with all Federal, State, Provincial, and
Local codes, regulations, and practices. Rheem Sales Company, Inc.
P.O. Box 17010, Fort Smith, AR 72917
“In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice.”
PRINTED IN U.S.A. 10-09 DC FORM NO. X33-1208 REV. 2
Supersedes Form No. X33-1208 Rev. 1