Rheem Package Dedicated Horizontal Heat Pump Submittal Sheet
Rheem-Package-Dedicated-Horizontal-Heat-Pump-Submittal-Sheet-684033 rheem-package-dedicated-horizontal-heat-pump-submittal-sheet-684033
2015-04-02
: Rheem Rheem-Package-Dedicated-Horizontal-Heat-Pump-Submittal-Sheet-684037 rheem-package-dedicated-horizontal-heat-pump-submittal-sheet-684037 rheem pdf
Open the PDF directly: View PDF .
Page Count: 3
Download | |
Open PDF In Browser | View PDF |
SUBMITTAL COVER SHEET PROJECT NAME ______________________________________________________________________________ LOCATION __________________________________________________________________________________ ARCHITECT__________________________________________________________________________________ ENGINEER __________________________________________________________________________________ CONTRACTOR ______________________________________________________________________________ SUBMITTED BY ______________________________ DATE ________________________________________ UNIT SUMMARY Quantity Unit Designation Model No. Total Cooling Sensible Cooling Air Ent. Evaporator Air Lvg. Evaporator Heating Input Heating Output CFM/ESP EER/SEER Electrical Minimum Ampacity Min.-Max. Breaker Net Unit Weight Accessory Catalog Form Number ACCESSORIES: PRINTED IN U.S.A. NOTES: 3-02 DC FORM NO. X11-1123 REV. 1 Supersedes Form No. X11-1123 Rev. 0 FORM NO. X33-1238 Supersedes Form No. X33-1139 Rev. 0 SUBMITTAL SHEET FOR PACKAGE HEAT PUMP UNITS FEATURING EARTH-FRIENDLY R-410A REFRIGERANT RQNM- 13-SEER SERIES RQPM- 14-SEER SERIES earth friendly refrigerant Nominal Sizes 2 thru 5 Tons [7-17.6 kW] JOB NAME DATE CONTRACTOR UNIT DESIGNATION ENGINEER MODEL NO. SUBMITTED FOR APPROVAL SUBMITTED BY RECORD LOCATION ORDER NO. UNIT DATA FEATURES FOR RQNM/RQPM- COOLING PERFORMANCE • Scroll Compressor • Copper Tube/Aluminum Fin Coils • Powder painted louvered steel cabinet protects coil from damage • Painted Base Pan • Demand Defrost Control • Non-Cycling Reversing Valve • Gauge Ports • Control box is fully accessible • Power and control wiring are kept separate • Certified and rated under ARI Standard 240 • U.L. listed • Factory run tested prior to shipment • Factory limited warranty on parts as follows: Compressor 13 SEER, 1 Phase, Residential Applications ....Eight (8) Years 14 SEER, 1 Phase, Residential Applications ....Ten (10) Years 13 & 14 SEER, Commercial Applications........Five (5) Years Any Other Part ................................................Five (5) Years 1 Phase, Residential Applications ......................Five (5) Years 1 & 3 Phase, Commercial Applications ................One (1) Year TOTAL CAPACITY* ........................ _______ MBH SENSIBLE CAPACITY* .................. _______ MBH OUTDOOR DESIGN TEMP. _______ °F [°C] DB/WB TOTAL SUPPLY AIR ................ _______ CFM [L/s] TEMP. OF AIR ENTERING EVAPORATOR COIL...... _______ °F [°C] DB/WB POWER INPUT REQUIREMENT ...... _______ KW SEER RATING........................................ _______ (*uses blower motor heat) HEATING PERFORMANCE GAS HEAT INPUT CAPACITY.......... _______ MBH HEAT PUMP HEATING PERFORMANCE CAPACITY @ 47°F .......................... ________MBH CAPACITY @ 17°F .......................... ________MBH COEFFICIENT OF PERFORMANCE @ 47°F............................................ ________C.O.P. @ 17°F............................................ ________C.O.P. ELECTRIC HEAT CAPACITY ............ _______ KW H.S.P.F. ...................................................... _______ SUPPLY AIR BLOWER PERFORMANCE TOTAL SUPPLY AIR ................ _______ CFM [L/s] TOTAL RESISTANCE EXTERNAL TO UNIT...................................... _______ IWG BLOWER SPEED .......................... _______ RPM POWER OUTPUT REQUIREMENT .. _______ BHP MOTOR RATING ........................ _______ HP [W] POWER INPUT REQUIREMENT ...... _______ KW ELECTRICAL DATA 208-230V/3PH/60Hz ____/____/____ POWER SUPPLY ........................ TOTAL UNIT AMPACITY................ _______ AMPS MINIMUM WIRE SIZE .................... _______ AWG MAXIMUM OVERCURRENT DEVICE FUSES HACR BREAKER ........ _______ AMPS TOTAL UNIT WEIGHT TOTAL OPERATING WEIGHT .... _______ LBS [kg] (including field-installed accessories) CLEARANCES SIDE “A” 18" [457 mm] SIDE “B” 0" [304 mm] SIDE “C” 12" [305 mm] SIDE “D” 30" [762 mm] ABOVE UNIT 60" [1524 mm] [ ] Designates Metric Conversions DIMENSIONS FRONT VIEW Model Height “A” 024, 030, 036 042, 048, 060 29 1/8" 37 1/8" 59 [1498.6 mm] CONDENSATE DRAIN PAN ACCESS A CONTROL BOX ACCESS 91/2 [241.3 mm] 211/16 [266.7 mm] 235/16 [592.1 mm] CL 151/2 [393.7 mm] 31/16 [77.7 mm] 531/2 [1358.9 mm] REAR VIEW ELECTRICAL CONNECTIONS BOTTOM VIEW RECOMMENDED UNIT DISCONNECT LOCATION AUXILIARY HIGH VOLTAGE ENTRANCE 123/32 [43.7 mm] 313/64 [81.2 mm] LOW VOLTAGE ENTRANCE 7/8 [22.2 mm] 33/4 [95.3 mm] 721/32 [194.3 mm] PRIMARY HIGH VOLTAGE 413/32 ENTRANCE [111.8 mm] 123/32 [43.7 mm] 59/64 [130.5 mm] 57/8 [149.5 mm] 197/8 [505 mm] Before proceeding with installation, refer to installation instructions packaged with each model, as well as complying with all Federal, State, Provincial, and Local codes, regulations, and practices. 31/2 [88.9 mm] [ ] Designates Metric Conversions RHEEM MANUFACTURING COMPANY 5600 Old Greenwood Road, Fort Smith, Arkansas 72908 “In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice.” PRINTED IN U.S.A. 5-06 DC FORM NO. X33-1238 Supersedes Form No. X33-1139 Rev. 0
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.3 Linearized : No Create Date : 2006:05:15 16:08:29 Producer : Acrobat Distiller 4.0 for Macintosh Modify Date : 2006:05:15 16:22:48-05:00 Page Count : 3 Has XFA : NoEXIF Metadata provided by EXIF.tools