PROJECT NAME ______________________________________________________________________________
LOCATION __________________________________________________________________________________
ARCHITECT__________________________________________________________________________________
ENGINEER __________________________________________________________________________________
CONTRACTOR ______________________________________________________________________________
SUBMITTED BY ______________________________ DATE ________________________________________
UNIT SUMMARY
SUBMITTAL COVER SHEET
Quantity
Unit Designation
Model No.
Total Cooling
Sensible Cooling
Air Ent. Evaporator
Air Lvg. Evaporator
Heating Input
Heating Output
CFM/ESP
EER/SEER
Electrical
Minimum Ampacity
Min.-Max. Breaker
Net Unit Weight
Accessory
Catalog Form Number
ACCESSORIES: NOTES:
PRINTED IN U.S.A. 3-02 DC FORM NO. X11-1123 REV. 1
Supersedes Form No. X11-1123 Rev. 0
SUBMITTAL SHEET FOR PACKAGE HEAT PUMP UNITS
FEATURING EARTH-FRIENDLY R-410A REFRIGERANT
RQNM- 13-SEER SERIES
RQPM- 14-SEER SERIES
Nominal Sizes 2 thru 5 Tons [7-17.6 kW]
JOB NAME DATE
CONTRACTOR UNIT DESIGNATION
ENGINEER MODEL NO.
SUBMITTED FOR APPROVAL RECORD LOCATION
SUBMITTED BY ORDER NO.
FORM NO. X33-1238
Supersedes Form No. X33-1139 Rev. 0
UNIT DATA
COOLING PERFORMANCE
TOTAL CAPACITY* ........................ _______ MBH
SENSIBLE CAPACITY* .................. _______ MBH
OUTDOOR DESIGN TEMP. _______ °F [°C] DB/WB
TOTAL SUPPLY AIR ................ _______ CFM [L/s]
TEMP. OF AIR ENTERING
EVAPORATOR COIL...... _______ °F [°C] DB/WB
POWER INPUT REQUIREMENT ...... _______ KW
SEER RATING........................................ _______
(*uses blower motor heat)
HEATING PERFORMANCE
GAS HEAT INPUT CAPACITY.......... _______ MBH
HEAT PUMP HEATING PERFORMANCE
CAPACITY @ 47°F .......................... ________MBH
CAPACITY @ 17°F .......................... ________MBH
COEFFICIENT OF PERFORMANCE
@ 47°F............................................ ________C.O.P.
@ 17°F............................................ ________C.O.P.
ELECTRIC HEAT CAPACITY ............ _______ KW
H.S.P.F. ...................................................... _______
SUPPLY AIR BLOWER PERFORMANCE
TOTAL SUPPLY AIR ................ _______ CFM [L/s]
TOTAL RESISTANCE EXTERNAL
TO UNIT...................................... _______ IWG
BLOWER SPEED .......................... _______ RPM
POWER OUTPUT REQUIREMENT .. _______ BHP
MOTOR RATING ........................ _______ HP [W]
POWER INPUT REQUIREMENT ...... _______ KW
ELECTRICAL DATA
POWER SUPPLY ........................ ____/____/____
TOTAL UNIT AMPACITY................ _______ AMPS
MINIMUM WIRE SIZE .................... _______ AWG
MAXIMUM OVERCURRENT DEVICE
FUSES HACR BREAKER ........ _______ AMPS
TOTAL UNIT WEIGHT
TOTAL OPERATING WEIGHT .... _______ LBS [kg]
(including field-installed accessories)
CLEARANCES
SIDE “A 18" [457 mm]
SIDE “B” 0" [304 mm]
SIDE “C” 12" [305 mm]
SIDE “D” 30" [762 mm]
ABOVE UNIT 60" [1524 mm]
FEATURES FOR RQNM/RQPM-
Scroll Compressor
Copper Tube/Aluminum Fin Coils
Powder painted louvered steel cabinet protects coil from
damage
Painted Base Pan
Demand Defrost Control
Non-Cycling Reversing Valve
Gauge Ports
Control box is fully accessible
Power and control wiring are kept separate
Certified and rated under ARI Standard 240
U.L. listed
Factory run tested prior to shipment
Factory limited warranty on parts as follows:
Compressor
13 SEER, 1 Phase, Residential Applications ....Eight (8) Years
14 SEER, 1 Phase, Residential Applications ....Ten (10) Years
13 & 14 SEER, Commercial Applications........Five (5) Years
Any Other Part ................................................Five (5) Years
1 Phase, Residential Applications ......................Five (5) Years
1 & 3 Phase, Commercial Applications ................One (1) Year
[ ] Designates Metric Conversions
earth friendly refrigerant
208-230V/3PH/60Hz
Before proceeding with installation, refer
to installation instructions packaged
with each model, as well as complying
with all Federal, State, Provincial, and
Local codes, regulations, and practices.
RHEEM
MANUFACTURING
COMPANY
5600 Old Greenwood Road, Fort Smith, Arkansas 72908
“In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice.
PRINTED IN U.S.A. 5-06 DC FORM NO. X33-1238
Supersedes Form No. X33-1139 Rev. 0
[ ] Designates Metric Conversions
PRIMARY
HIGH VOLTAGE
ENTRANCE
123/32 [43.7 mm]
413/32
[111.8 mm]
59/64
[130.5 mm]
197/8
[505 mm]
57/8
[149.5 mm]
31/2
[88.9 mm]
33/4
[95.3 mm]
721/32
[194.3 mm]
313/64
[81.2 mm]
AUXILIARY
HIGH VOLTAGE
ENTRANCE
123/32[43.7 mm]
LOW VOLTAGE
ENTRANCE 7/8[22.2 mm]
RECOMMENDED UNIT
DISCONNECT LOCATION
211/16
[266.7 mm]
91/2
[241.3 mm]
59
[1498.6 mm]
151/2
[393.7 mm]
531/2
[1358.9 mm]
235/16
[592.1 mm] 31/16
[77.7 mm]
A
CONTROL
BOX ACCESS
CONDENSATE
DRAIN
PAN
ACCESS
C
L
Model
024, 030, 036
042, 048, 060
Height “A”
29 1/8"
37 1/8"
DIMENSIONS FRONT VIEW
REAR VIEW
ELECTRICAL CONNECTIONS BOTTOM VIEW